Search criteria

6 vulnerabilities found for oda_viewer by opendesign

FKIE_CVE-2021-43276

Vulnerability from fkie_nvd - Published: 2021-11-14 21:15 - Updated: 2024-11-21 06:28
Summary
An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process
Impacted products
Vendor Product Version
opendesign oda_viewer *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:opendesign:oda_viewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1099B3A5-5EEF-4F8B-B64C-152490C6D850",
              "versionEndExcluding": "2022.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process"
    },
    {
      "lang": "es",
      "value": "Se presenta una vulnerabilidad de lectura fuera de l\u00edmites en Open Design Alliance ODA Viewer versiones anteriores a 2022.8. Los datos dise\u00f1ados en un archivo DWF pueden desencadenar una lectura m\u00e1s all\u00e1 del final de un b\u00fafer asignado. Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo arbitrario en el contexto del proceso actual"
    }
  ],
  "id": "CVE-2021-43276",
  "lastModified": "2024-11-21T06:28:58.880",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-11-14T21:15:08.043",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.opendesign.com/security-advisories"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.opendesign.com/security-advisories"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-125"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-43272

Vulnerability from fkie_nvd - Published: 2021-11-14 21:15 - Updated: 2024-11-21 06:28
Severity ?
Summary
An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process.
Impacted products
Vendor Product Version
opendesign oda_viewer *

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:opendesign:oda_viewer:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D20B19A6-CA45-4FB5-B99C-5D040CF7956C",
              "versionEndExcluding": "2022.11",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad de manejo inapropiado de condiciones excepcionales es presentado en Open Design Alliance ODA Viewer sample versiones anteriores a 2022.11. ODA Viewer contin\u00faa procesando archivos DWF inv\u00e1lidos o maliciosos en lugar de detenerse ante una excepci\u00f3n. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual"
    }
  ],
  "id": "CVE-2021-43272",
  "lastModified": "2024-11-21T06:28:58.143",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-11-14T21:15:07.850",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.opendesign.com/security-advisories"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.opendesign.com/security-advisories"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-755"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2021-43272 (GCVE-0-2021-43272)

Vulnerability from cvelistv5 – Published: 2021-11-14 20:59 – Updated: 2024-08-04 03:55
VLAI?
Summary
An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:55:28.419Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-30T11:06:17",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.opendesign.com/security-advisories"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43272",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.opendesign.com/security-advisories",
              "refsource": "MISC",
              "url": "https://www.opendesign.com/security-advisories"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43272",
    "datePublished": "2021-11-14T20:59:16",
    "dateReserved": "2021-11-02T00:00:00",
    "dateUpdated": "2024-08-04T03:55:28.419Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43276 (GCVE-0-2021-43276)

Vulnerability from cvelistv5 – Published: 2021-11-14 20:51 – Updated: 2024-08-04 03:55
VLAI?
Summary
An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:55:28.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.opendesign.com/security-advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-14T20:51:18",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.opendesign.com/security-advisories"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43276",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.opendesign.com/security-advisories",
              "refsource": "MISC",
              "url": "https://www.opendesign.com/security-advisories"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43276",
    "datePublished": "2021-11-14T20:51:18",
    "dateReserved": "2021-11-02T00:00:00",
    "dateUpdated": "2024-08-04T03:55:28.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43272 (GCVE-0-2021-43272)

Vulnerability from nvd – Published: 2021-11-14 20:59 – Updated: 2024-08-04 03:55
VLAI?
Summary
An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:55:28.419Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.opendesign.com/security-advisories"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-30T11:06:17",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.opendesign.com/security-advisories"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43272",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An improper handling of exceptional conditions vulnerability exists in Open Design Alliance ODA Viewer sample before 2022.11. ODA Viewer continues to process invalid or malicious DWF files instead of stopping upon an exception. An attacker can leverage this vulnerability to execute code in the context of the current process."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.opendesign.com/security-advisories",
              "refsource": "MISC",
              "url": "https://www.opendesign.com/security-advisories"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1363/"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1360/"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-1358/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43272",
    "datePublished": "2021-11-14T20:59:16",
    "dateReserved": "2021-11-02T00:00:00",
    "dateUpdated": "2024-08-04T03:55:28.419Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-43276 (GCVE-0-2021-43276)

Vulnerability from nvd – Published: 2021-11-14 20:51 – Updated: 2024-08-04 03:55
VLAI?
Summary
An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:55:28.265Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.opendesign.com/security-advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-14T20:51:18",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.opendesign.com/security-advisories"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-43276",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Out-of-bounds Read vulnerability exists in Open Design Alliance ODA Viewer before 2022.8. Crafted data in a DWF file can trigger a read past the end of an allocated buffer. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current process"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.opendesign.com/security-advisories",
              "refsource": "MISC",
              "url": "https://www.opendesign.com/security-advisories"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-43276",
    "datePublished": "2021-11-14T20:51:18",
    "dateReserved": "2021-11-02T00:00:00",
    "dateUpdated": "2024-08-04T03:55:28.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}