Search criteria

6 vulnerabilities found for officeconnect_1850_24g_2xgt_poe\+_firmware by hpe

FKIE_CVE-2022-37934

Vulnerability from fkie_nvd - Published: 2023-01-05 07:15 - Updated: 2025-04-10 16:15
Summary
A potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:officeconnect_1820_24g_poe\\+_\\(185w\\)_switch_j9983a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DB33F73-2104-4D29-B92F-E2E4C3EE2E54",
              "versionEndExcluding": "pt.02.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:officeconnect_1820_24g_poe\\+_\\(185w\\)_switch_j9983a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5264853E-2649-4C44-B078-796A02BC53B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:officeconnect_1820_48g_poe\\+_\\(370w\\)_switch_j9984a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83B4E0B4-C6EE-470F-A2D5-9621FD2829D0",
              "versionEndExcluding": "pt.02.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:officeconnect_1820_48g_poe\\+_\\(370w\\)_switch_j9984a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "19B37EFA-2611-443A-B1EB-2687D6BD5C2A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:officeconnect_1820_8g_poe\\+_\\(65w\\)_switch_j9982a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE77545A-B7D1-4489-87F5-1404BAA66AEB",
              "versionEndExcluding": "pt.02.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:officeconnect_1820_8g_poe\\+_\\(65w\\)_switch_j9982a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78A4E198-C861-4961-8AF4-23BEAB22DBF2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:officeconnect_1820_8g_switch_j9979a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "917D4AE7-9EBD-431C-A637-C5F9CB87F2E4",
              "versionEndExcluding": "pt.02.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:officeconnect_1820_8g_switch_j9979a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6829C8C-511C-4BD7-BC9A-215D34B025E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_24g_2xgt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5B71880-1BE7-4978-8B0B-78E2B30630A0",
              "versionEndExcluding": "pc.01.23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_24g_2xgt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DF9BC87-425B-4965-B0BB-9B11B6BE5DAE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_24g_2xgt_poe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEB0330A-A8F8-4B10-AA32-072D66E815E5",
              "versionEndExcluding": "pc.01.23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_24g_2xgt_poe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1384A4C-5F0A-4F34-BB26-BFD9CDE56C1A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_2xgt\\/spf\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9110CF1C-484C-4974-90F4-A1D91FCDD0B5",
              "versionEndExcluding": "po.01.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_2xgt\\/spf\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90F00E23-350B-4117-96E4-A342790992B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_48g_4xgt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2C5EAAF-BC29-487E-B1BA-15E2E1BC75BE",
              "versionEndExcluding": "pc.01.23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_48g_4xgt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD61C53-261D-4155-800E-CE5709BFAA90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_48g_4xgt_poe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64565539-4629-42A0-BC97-E88D5C692034",
              "versionEndExcluding": "pc.01.23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_48g_4xgt_poe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34CC05B8-2AC3-4379-8E27-B771F520EF97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_6xgt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B255A45-60D8-4E18-9005-9A666704B227",
              "versionEndExcluding": "pc.01.23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_6xgt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A0AAED7-FCBB-40E6-9649-617F1CD62A34",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.\n\n"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una posible vulnerabilidad de seguridad en las series de conmutadores HPE OfficeConnect 1820 y 1850. La vulnerabilidad podr\u00eda explotarse de forma remota para permitir el directory traversal de manera remota en la versi\u00f3n PT.02.17 y anteriores de la serie de conmutadores HPE OfficeConnect 1820, la versi\u00f3n PC.01.23 y posteriores de la serie de conmutadores HPE OfficeConnect 1850 y la versi\u00f3n PO.01.22 y PO.01.22 de la serie de conmutadores HPE OfficeConnect 1850 (agregador 10G). abajo."
    }
  ],
  "id": "CVE-2022-37934",
  "lastModified": "2025-04-10T16:15:20.107",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 4.0,
        "source": "security-alert@hpe.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-01-05T07:15:10.257",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04401en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04401en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2022-37932

Vulnerability from fkie_nvd - Published: 2022-12-12 13:15 - Updated: 2024-11-21 07:15
Summary
A potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;
Impacted products
Vendor Product Version
hpe officeconnect_1820_j9979a_firmware *
hpe officeconnect_1820_j9979a -
hpe officeconnect_1820_j9982a_firmware *
hpe officeconnect_1820_j9982a -
hpe officeconnect_1820_j9980a_firmware *
hpe officeconnect_1820_j9980a -
hpe officeconnect_1820_j9983a_firmware *
hpe officeconnect_1820_j9983a -
hpe officeconnect_1820_j9981a_firmware *
hpe officeconnect_1820_j9981a -
hpe officeconnect_1820_j9984a_firmware *
hpe officeconnect_1820_j9984a -
hpe officeconnect_1850_24g_2xgt_poe\+_firmware *
hpe officeconnect_1850_24g_2xgt_poe\+ -
hpe officeconnect_1850_24g_2xgt_firmware *
hpe officeconnect_1850_24g_2xgt -
hpe officeconnect_1850_48g_4xgt_poe\+_firmware *
hpe officeconnect_1850_48g_4xgt_poe\+ -
hpe officeconnect_1850_48g_4xgt_firmware *
hpe officeconnect_1850_48g_4xgt -
hpe officeconnect_1850_6xgt_firmware *
hpe officeconnect_1850_6xgt -
hpe officeconnect_1850_2xgt\/spf\+_firmware *
hpe officeconnect_1850_2xgt\/spf\+ -
hpe officeconnect_1920s_24g_2sfp_poe\+_firmware *
hpe officeconnect_1920s_24g_2sfp_poe\+ -
hpe officeconnect_1920s_24g_2sfp_ppoe\+_firmware *
hpe officeconnect_1920s_24g_2sfp_ppoe\+ -
hpe officeconnect_1920s_24g_2sfp_firmware *
hpe officeconnect_1920s_24g_2sfp -
hpe officeconnect_1920s_48g_4sfp_ppoe\+_firmware *
hpe officeconnect_1920s_48g_4sfp_ppoe\+ -
hpe officeconnect_1920s_48g_4sfp_firmware *
hpe officeconnect_1920s_48g_4sfp -
hpe officeconnect_1920s_8g_ppoe\+_firmware *
hpe officeconnect_1920s_8g_ppoe\+ -
hpe officeconnect_1920s_8g_firmware *
hpe officeconnect_1920s_8g -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1820_j9979a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFAABEF2-F55F-49FE-9BDB-E6A07F3B9668",
              "versionEndExcluding": "pt.02.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1820_j9979a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A7F9F10C-0FD7-4224-8604-D40772A6D325",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1820_j9982a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CD349A82-736E-48AB-A16F-B7F09A540AF5",
              "versionEndExcluding": "pt.02.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1820_j9982a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7647988C-38C0-4866-9D14-EB0A5380FF85",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1820_j9980a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84C2E422-9A0E-4D91-93BE-C4DD0083CA65",
              "versionEndExcluding": "pt.02.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1820_j9980a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC221BBC-AFD9-4115-A4A6-ACB64E8B1498",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1820_j9983a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A8AE93C-B333-430E-B5FE-E072EAB83599",
              "versionEndExcluding": "pt.02.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1820_j9983a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDDC1474-AC0F-4A9D-AE34-3C1037346A9D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1820_j9981a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DD62A3-CE10-4343-BDC4-73A84E892F13",
              "versionEndExcluding": "pt.02.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1820_j9981a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFAE1036-E1F0-46EE-8FA3-0204299258C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1820_j9984a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6467F62-F15A-469B-BEC5-9E11A242B6FC",
              "versionEndExcluding": "pt.02.14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1820_j9984a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88C9CDFE-A010-4B48-A7C0-493D82B654F8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_24g_2xgt_poe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66948DB9-F00D-40A4-8B32-B6E49A24FA25",
              "versionEndExcluding": "pc.01.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_24g_2xgt_poe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1384A4C-5F0A-4F34-BB26-BFD9CDE56C1A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_24g_2xgt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3377E5AB-1864-4465-AD35-616E1A806384",
              "versionEndExcluding": "pc.01.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_24g_2xgt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3DF9BC87-425B-4965-B0BB-9B11B6BE5DAE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_48g_4xgt_poe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34F06E1A-4EFE-41EA-97C6-7139DD013AFB",
              "versionEndExcluding": "pc.01.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_48g_4xgt_poe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34CC05B8-2AC3-4379-8E27-B771F520EF97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_48g_4xgt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5EDD55A8-3C69-4B53-A3C0-F0E2A9B4692A",
              "versionEndExcluding": "pc.01.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_48g_4xgt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD61C53-261D-4155-800E-CE5709BFAA90",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_6xgt_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F0CBEF7-0963-45F9-B4A5-DC04909D4B12",
              "versionEndExcluding": "po.01.21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_6xgt:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A0AAED7-FCBB-40E6-9649-617F1CD62A34",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1850_2xgt\\/spf\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A208318-52FA-4E1F-A62E-F2667CE9F132",
              "versionEndExcluding": "po.01.21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1850_2xgt\\/spf\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "90F00E23-350B-4117-96E4-A342790992B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_24g_2sfp_poe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "410FE7C9-6757-4B7D-88C7-5FAB7E11F970",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_24g_2sfp_poe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75407C01-1A83-43A4-9C75-6EBDED3DE676",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_24g_2sfp_ppoe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "422F8D41-CA36-42A1-9201-F7D438E30BB6",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_24g_2sfp_ppoe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E44086E4-506F-44D6-95A7-112BFD8AB2EC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_24g_2sfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "21CC988D-9798-4131-8DBA-D769EAC50F17",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_24g_2sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82FC497B-C6D9-46E9-AC07-0AFED63A7FD4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_48g_4sfp_ppoe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCE3C410-DCA7-44E4-9425-B9ABBAAB68E1",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_48g_4sfp_ppoe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E26FF87F-A734-4E79-B08D-7FB97564DF99",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_48g_4sfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF9C79BA-8094-4976-B9A0-BC9008A3AE57",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_48g_4sfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C916A687-153B-42D6-95A7-2B6CC39E36C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_8g_ppoe\\+_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4991134-1AC5-401E-B942-486CB7B9D184",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_8g_ppoe\\+:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA52CA14-46DC-4C72-92D8-F065500E0F64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hpe:officeconnect_1920s_8g_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "295C6B0F-83E7-4242-BF64-968B8D2536DE",
              "versionEndExcluding": "pd.02.22",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hpe:officeconnect_1920s_8g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0686F303-D228-4D0A-8648-67930EFA8395",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;\n\n"
    },
    {
      "lang": "es",
      "value": "Se ha identificado una posible vulnerabilidad de seguridad en los conmutadores de red Hewlett Packard Enterprise OfficeConnect 1820, 1850 y 1920S. La vulnerabilidad podr\u00eda explotarse de forma remota para permitir omitir la autenticaci\u00f3n. HPE ha realizado las siguientes actualizaciones de software para resolver la vulnerabilidad en las versiones de los conmutadores de red Hewlett Packard Enterprise OfficeConnect 1820, 1850 y 1920S: anteriores a PT.02.14; Antes de PC.01.22; Antes de PO.01.21; Antes del PD.02.22;"
    }
  ],
  "id": "CVE-2022-37932",
  "lastModified": "2024-11-21T07:15:24.617",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "security-alert@hpe.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-12-12T13:15:14.360",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04383en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04383en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2022-37934 (GCVE-0-2022-37934)

Vulnerability from cvelistv5 – Published: 2023-01-03 18:33 – Updated: 2025-04-10 15:42
VLAI?
Summary
A potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.
CWE
  • n/a
Assigner
hpe
Impacted products
Vendor Product Version
Hewlett Packard Enterprise (HPE) HPE OfficeConnect 1820 and 1850 Switch Series Affected: Prior to PT.02.17; Prior to PC.01.23; Prior to PO.01.22
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.572Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04401en_us"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-37934",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-10T15:42:41.310394Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-22",
                "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T15:42:45.470Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "HPE OfficeConnect 1820 and 1850 Switch Series",
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to PT.02.17; Prior to PC.01.23; Prior to PO.01.22"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.\u003c/p\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-05T05:58:57.684Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04401en_us"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "cveClient/1.0.13"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2022-37934",
    "datePublished": "2023-01-03T18:33:15.954Z",
    "dateReserved": "2022-08-08T18:49:44.387Z",
    "dateUpdated": "2025-04-10T15:42:45.470Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-37932 (GCVE-0-2022-37932)

Vulnerability from cvelistv5 – Published: 2022-11-30 15:23 – Updated: 2025-04-24 18:42
VLAI?
Summary
A potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;
CWE
  • n/a
Assigner
hpe
Impacted products
Vendor Product Version
Hewlett Packard Enterprise (HPE) Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches Affected: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.568Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04383en_us"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-37932",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-24T18:35:07.362377Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "description": "CWE-noinfo Not enough information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-24T18:42:08.233Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches",
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;\u003c/p\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T12:11:04.548Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04383en_us"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "cveClient/1.0.13"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2022-37932",
    "datePublished": "2022-11-30T15:23:14.750Z",
    "dateReserved": "2022-08-08T18:49:44.386Z",
    "dateUpdated": "2025-04-24T18:42:08.233Z",
    "requesterUserId": "6707ad87-4508-4473-b324-feac48da5e14",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-37934 (GCVE-0-2022-37934)

Vulnerability from nvd – Published: 2023-01-03 18:33 – Updated: 2025-04-10 15:42
VLAI?
Summary
A potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.
CWE
  • n/a
Assigner
hpe
Impacted products
Vendor Product Version
Hewlett Packard Enterprise (HPE) HPE OfficeConnect 1820 and 1850 Switch Series Affected: Prior to PT.02.17; Prior to PC.01.23; Prior to PO.01.22
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.572Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04401en_us"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-37934",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-10T15:42:41.310394Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-22",
                "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T15:42:45.470Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "HPE OfficeConnect 1820 and 1850 Switch Series",
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to PT.02.17; Prior to PC.01.23; Prior to PO.01.22"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.\u003c/p\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in HPE OfficeConnect 1820, and 1850 switch series. The vulnerability could be remotely exploited to allow remote directory traversal in HPE OfficeConnect 1820 switch series version PT.02.17 and below, HPE OfficeConnect 1850 switch series version PC.01.23 and below, and HPE OfficeConnect 1850 (10G aggregator) switch version PO.01.22 and below.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-05T05:58:57.684Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04401en_us"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "cveClient/1.0.13"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2022-37934",
    "datePublished": "2023-01-03T18:33:15.954Z",
    "dateReserved": "2022-08-08T18:49:44.387Z",
    "dateUpdated": "2025-04-10T15:42:45.470Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-37932 (GCVE-0-2022-37932)

Vulnerability from nvd – Published: 2022-11-30 15:23 – Updated: 2025-04-24 18:42
VLAI?
Summary
A potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;
CWE
  • n/a
Assigner
hpe
Impacted products
Vendor Product Version
Hewlett Packard Enterprise (HPE) Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches Affected: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:37:42.568Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04383en_us"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-37932",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-24T18:35:07.362377Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "description": "CWE-noinfo Not enough information",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-24T18:42:08.233Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches",
          "vendor": "Hewlett Packard Enterprise (HPE)",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;\u003c/p\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in Hewlett Packard Enterprise OfficeConnect 1820, 1850, and 1920S Network switches. The vulnerability could be remotely exploited to allow authentication bypass. HPE has made the following software updates to resolve the vulnerability in Hewlett Packard Enterprise OfficeConnect 1820, 1850 and 1920S Network switches versions: Prior to PT.02.14; Prior to PC.01.22; Prior to PO.01.21; Prior to PD.02.22;\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-12T12:11:04.548Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbnw04383en_us"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "cveClient/1.0.13"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2022-37932",
    "datePublished": "2022-11-30T15:23:14.750Z",
    "dateReserved": "2022-08-08T18:49:44.386Z",
    "dateUpdated": "2025-04-24T18:42:08.233Z",
    "requesterUserId": "6707ad87-4508-4473-b324-feac48da5e14",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}