24 vulnerabilities found for oncell_g3470a-lte-eu-t_firmware by moxa

FKIE_CVE-2024-4641

Vulnerability from fkie_nvd - Published: 2024-06-25 10:15 - Updated: 2025-03-10 20:05
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9F52AF7-B4F6-4A74-AB10-EE7BED739E1B",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A599BB3F-33B0-434F-8F74-D4E77DA73EBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D66E977-C246-4AE1-B98A-C5E53B05AEE4",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E18DFB2B-98A9-49B4-9338-404DDD5D03DE",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2530C6D4-CA66-4932-A943-FA8318819868",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14AC6DF-528B-479F-945C-B8268B22AD75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de la serie OnCell G3470A-LTE v1.7.7 y anteriores se han identificado como vulnerables debido a que aceptan una cadena de formato de una fuente externa como argumento. Un atacante podr\u00eda modificar una cadena de formato controlada externamente para provocar una p\u00e9rdida de memoria y una denegaci\u00f3n de servicio."
    }
  ],
  "id": "CVE-2024-4641",
  "lastModified": "2025-03-10T20:05:10.410",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.4,
        "source": "psirt@moxa.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-25T10:15:21.000",
  "references": [
    {
      "source": "psirt@moxa.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    }
  ],
  "sourceIdentifier": "psirt@moxa.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-134"
        }
      ],
      "source": "psirt@moxa.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-134"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2024-4640

Vulnerability from fkie_nvd - Published: 2024-06-25 10:15 - Updated: 2025-03-10 20:06

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9F52AF7-B4F6-4A74-AB10-EE7BED739E1B",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A599BB3F-33B0-434F-8F74-D4E77DA73EBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D66E977-C246-4AE1-B98A-C5E53B05AEE4",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E18DFB2B-98A9-49B4-9338-404DDD5D03DE",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2530C6D4-CA66-4932-A943-FA8318819868",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14AC6DF-528B-479F-945C-B8268B22AD75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de la serie OnCell G3470A-LTE v1.7.7 y anteriores se han identificado como vulnerables debido a la falta de verificaci\u00f3n de los l\u00edmites en las operaciones del b\u00fafer. Un atacante podr\u00eda escribir m\u00e1s all\u00e1 de los l\u00edmites de las regiones del b\u00fafer asignadas en la memoria, provocando un bloqueo del programa."
    }
  ],
  "id": "CVE-2024-4640",
  "lastModified": "2025-03-10T20:06:21.840",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.2,
        "source": "psirt@moxa.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-25T10:15:20.780",
  "references": [
    {
      "source": "psirt@moxa.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    }
  ],
  "sourceIdentifier": "psirt@moxa.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "psirt@moxa.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2024-4639

Vulnerability from fkie_nvd - Published: 2024-06-25 10:15 - Updated: 2025-03-10 20:07
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9F52AF7-B4F6-4A74-AB10-EE7BED739E1B",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A599BB3F-33B0-434F-8F74-D4E77DA73EBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D66E977-C246-4AE1-B98A-C5E53B05AEE4",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E18DFB2B-98A9-49B4-9338-404DDD5D03DE",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2530C6D4-CA66-4932-A943-FA8318819868",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14AC6DF-528B-479F-945C-B8268B22AD75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de la serie OnCell G3470A-LTE v1.7.7 y anteriores han sido identificadas como vulnerables debido a la falta de entradas neutralizadas en la configuraci\u00f3n IPSec. Un atacante podr\u00eda modificar los comandos previstos enviados a las funciones de destino, lo que podr\u00eda provocar que usuarios malintencionados ejecuten comandos no autorizados."
    }
  ],
  "id": "CVE-2024-4639",
  "lastModified": "2025-03-10T20:07:31.447",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.2,
        "source": "psirt@moxa.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-25T10:15:19.897",
  "references": [
    {
      "source": "psirt@moxa.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    }
  ],
  "sourceIdentifier": "psirt@moxa.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "psirt@moxa.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2024-4638

Vulnerability from fkie_nvd - Published: 2024-06-25 09:15 - Updated: 2025-03-10 20:07
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E18DFB2B-98A9-49B4-9338-404DDD5D03DE",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D66E977-C246-4AE1-B98A-C5E53B05AEE4",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2530C6D4-CA66-4932-A943-FA8318819868",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14AC6DF-528B-479F-945C-B8268B22AD75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9F52AF7-B4F6-4A74-AB10-EE7BED739E1B",
              "versionEndIncluding": "1.7.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A599BB3F-33B0-434F-8F74-D4E77DA73EBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
    },
    {
      "lang": "es",
      "value": "Las versiones de firmware de la serie OnCell G3470A-LTE v1.7.7 y anteriores han sido identificadas como vulnerables debido a la falta de entradas neutralizadas en la funci\u00f3n de carga de clave web. Un atacante podr\u00eda modificar los comandos previstos enviados a las funciones de destino, lo que podr\u00eda provocar que usuarios malintencionados ejecuten comandos no autorizados."
    }
  ],
  "id": "CVE-2024-4638",
  "lastModified": "2025-03-10T20:07:01.110",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "LOW",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 4.2,
        "source": "psirt@moxa.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-25T09:15:57.413",
  "references": [
    {
      "source": "psirt@moxa.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
    }
  ],
  "sourceIdentifier": "psirt@moxa.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "psirt@moxa.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-39278

Vulnerability from fkie_nvd - Published: 2021-09-07 06:15 - Updated: 2024-11-21 06:19
Summary
Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
References
cve@mitre.orghttp://packetstormsecurity.com/files/164014Exploit, Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://packetstormsecurity.com/files/164014Exploit, Third Party Advisory, VDB Entry

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wac-2004_firmware:1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "83A3AA06-BC98-4CE7-A459-02C780480F8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wac-2004:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36B321C6-F7AF-48F4-8BDE-C42CD89383A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wac-1001_firmware:2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "78532D1A-BEB0-4AB0-BE6A-E1AC72CF3A57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wac-1001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB2E25B8-5545-480D-85D0-0DD303606547",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wac-1001-t_firmware:2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5F56865-9C52-47B4-A5DB-35872FA48FB6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wac-1001-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA14B9A7-17DF-4900-BA95-C78A43728847",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12BE8C4-D53A-4503-8492-66FC859FC0CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "A122A3AC-260D-443A-9684-D56CD64E6BC9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:tap-323-eu-ct-t_firmware:1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C009174-6441-4B8D-B233-3F976872F11D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:tap-323-eu-ct-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6ABD8F8-7308-47CE-B2C8-CC541D1C9F84",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:tap-323-us-ct-t_firmware:1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "30F156F3-DFE1-49F6-B298-122659A39B2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:tap-323-us-ct-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E536D7FF-BBB8-4D73-B8F9-CB07DDE2D847",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:tap-323-jp-ct-t_firmware:1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CD4A2E1-39D9-49D9-993E-0232F266C174",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:tap-323-jp-ct-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C05FA1B-7E9F-4B5D-AF1D-D4A88544323E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-eu_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "61124965-5F3D-4538-8166-1583854BF3E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E65A51A-86D6-40D4-ACAC-7F5643CAD53E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-eu-t_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "007B3B2D-52C1-4C92-89DC-7B3F4178ADDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B761D5AE-6766-42D1-A9FC-58602AF6888A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-us_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF5DAE18-342A-489F-9B79-1557468E41B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DD1F7FC-DBC6-4F1C-B224-EEDE7712AE18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-us-t_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC5BB237-0731-45C8-95BC-C152D5EF4949",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9822FD39-59C7-46B0-B39D-2AC3F6E369B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos MOXA permiten un ataque de tipo XSS reflejado por medio del men\u00fa Config Import. Esto afecta a WAC-2004 versi\u00f3n 1.7, WAC-1001 versi\u00f3n  2.1, WAC-1001-T versi\u00f3n  2.1, OnCell G3470A-LTE-EU versi\u00f3n  1.7, OnCell G3470A-LTE-EU-T versi\u00f3n  1.7, TAP-323-EU-CT-T versi\u00f3n  1.3, TAP-323-US-CT-T versi\u00f3n  1.3, TAP-323-JP-CT-T versi\u00f3n  1.3, WDR-3124A-EU versi\u00f3n  2.3, WDR-3124A-EU-T versi\u00f3n  2.3, WDR-3124A-US versi\u00f3n  2.3 y WDR-3124A-US-T versi\u00f3n  2.3"
    }
  ],
  "id": "CVE-2021-39278",
  "lastModified": "2024-11-21T06:19:06.177",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-09-07T06:15:08.270",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/164014"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://packetstormsecurity.com/files/164014"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-39279

Vulnerability from fkie_nvd - Published: 2021-09-07 06:15 - Updated: 2024-11-21 06:19
Summary
Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wac-2004_firmware:1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "83A3AA06-BC98-4CE7-A459-02C780480F8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wac-2004:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36B321C6-F7AF-48F4-8BDE-C42CD89383A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wac-1001_firmware:2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "78532D1A-BEB0-4AB0-BE6A-E1AC72CF3A57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wac-1001:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB2E25B8-5545-480D-85D0-0DD303606547",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wac-1001-t_firmware:2.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5F56865-9C52-47B4-A5DB-35872FA48FB6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wac-1001-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA14B9A7-17DF-4900-BA95-C78A43728847",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "F12BE8C4-D53A-4503-8492-66FC859FC0CA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:1.7:*:*:*:*:*:*:*",
              "matchCriteriaId": "A122A3AC-260D-443A-9684-D56CD64E6BC9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:tap-323-eu-ct-t_firmware:1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C009174-6441-4B8D-B233-3F976872F11D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:tap-323-eu-ct-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6ABD8F8-7308-47CE-B2C8-CC541D1C9F84",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:tap-323-us-ct-t_firmware:1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "30F156F3-DFE1-49F6-B298-122659A39B2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:tap-323-us-ct-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E536D7FF-BBB8-4D73-B8F9-CB07DDE2D847",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:tap-323-jp-ct-t_firmware:1.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CD4A2E1-39D9-49D9-993E-0232F266C174",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:tap-323-jp-ct-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C05FA1B-7E9F-4B5D-AF1D-D4A88544323E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-eu_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "61124965-5F3D-4538-8166-1583854BF3E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E65A51A-86D6-40D4-ACAC-7F5643CAD53E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-eu-t_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "007B3B2D-52C1-4C92-89DC-7B3F4178ADDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B761D5AE-6766-42D1-A9FC-58602AF6888A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-us_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF5DAE18-342A-489F-9B79-1557468E41B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8DD1F7FC-DBC6-4F1C-B224-EEDE7712AE18",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:wdr-3124a-us-t_firmware:2.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "BC5BB237-0731-45C8-95BC-C152D5EF4949",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:wdr-3124a-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9822FD39-59C7-46B0-B39D-2AC3F6E369B5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos MOXA permiten una inyecci\u00f3n de comandos autenticados por medio de /forms/web_importTFTP. Esto afecta a WAC-2004 versi\u00f3n 1.7, WAC-1001 versi\u00f3n 2.1, WAC-1001-T versi\u00f3n 2.1, OnCell G3470A-LTE-EU versi\u00f3n 1.7, OnCell G3470A-LTE-EU-T versi\u00f3n 1.7, TAP-323-EU-CT-T versi\u00f3n 1.3, TAP-323-US-CT-T versi\u00f3n 1.3, TAP-323-JP-CT-T versi\u00f3n 1.3, WDR-3124A-EU versi\u00f3n 2.3, WDR-3124A-EU-T versi\u00f3n 2.3, WDR-3124A-US versi\u00f3n 2.3 y WDR-3124A-US-T versi\u00f3n 2.3"
    }
  ],
  "id": "CVE-2021-39279",
  "lastModified": "2024-11-21T06:19:06.390",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-09-07T06:15:08.327",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com"
    },
    {
      "source": "nvd@nist.gov",
      "tags": [
        "Exploit",
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://packetstormsecurity.com/files/164014"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.moxa.com"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2018-11425

Vulnerability from fkie_nvd - Published: 2019-07-03 16:15 - Updated: 2024-11-21 03:43
Severity ?
Summary
Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "270BBCE9-E509-4030-9AEF-320CF98F0632",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14AC6DF-528B-479F-945C-B8268B22AD75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17E16880-6BCE-4B35-A003-AC0E3F4A961B",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A599BB3F-33B0-434F-8F74-D4E77DA73EBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BA29679-131C-4988-AA40-CC09C6307227",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45F6F8D-FCF7-4850-BF1E-8A2DB2D85593",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 un problema de corrupci\u00f3n de memoria en Moxa OnCell G3470A-LTE Series versi\u00f3n 1.6 Build 18021314 y anterior, una vulnerabilidad diferente a la CVE-2018-11424."
    }
  ],
  "id": "CVE-2018-11425",
  "lastModified": "2024-11-21T03:43:20.547",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-03T16:15:10.693",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2018-11424

Vulnerability from fkie_nvd - Published: 2019-07-03 16:15 - Updated: 2024-11-21 03:43
Summary
There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "270BBCE9-E509-4030-9AEF-320CF98F0632",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A14AC6DF-528B-479F-945C-B8268B22AD75",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-us-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17E16880-6BCE-4B35-A003-AC0E3F4A961B",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-us-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A599BB3F-33B0-434F-8F74-D4E77DA73EBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BA29679-131C-4988-AA40-CC09C6307227",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "620CD649-90E9-422A-9FF7-51C2FFF2DFDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:moxa:oncell_g3470a-lte-eu-t_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45F6F8D-FCF7-4850-BF1E-8A2DB2D85593",
              "versionEndIncluding": "1.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:moxa:oncell_g3470a-lte-eu-t:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E97DFAB-1D6E-4110-89C1-DD5616A6320B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425."
    },
    {
      "lang": "es",
      "value": "Existe corrupci\u00f3n de memoria en la interfaz web de Moxa OnCell G3470A-LTE Series versi\u00f3n 1.6 Build 18021314 y anterior, una vulnerabilidad diferente a la CVE-2018-11425."
    }
  ],
  "id": "CVE-2018-11424",
  "lastModified": "2024-11-21T03:43:20.400",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-07-03T16:15:10.617",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2024-4641 (GCVE-0-2024-4641)

Vulnerability from cvelistv5 – Published: 2024-06-25 09:23 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.
CWE
  • CWE-134 - Use of Externally-Controlled Format String
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g3470a-lte-us",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4641",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T17:38:59.616518Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:39:20.742Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.226Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-135",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-135: Format String Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-134",
              "description": "CWE-134: Use of Externally-Controlled Format String",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:23:30.502Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Format String Errors",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4641",
    "datePublished": "2024-06-25T09:23:30.502Z",
    "dateReserved": "2024-05-08T00:44:45.219Z",
    "dateUpdated": "2024-08-01T20:47:41.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4640 (GCVE-0-2024-4640)

Vulnerability from cvelistv5 – Published: 2024-06-25 09:19 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4640",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:15:03.203557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:15:08.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100: Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:19:08.712Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4640",
    "datePublished": "2024-06-25T09:19:08.712Z",
    "dateReserved": "2024-05-08T00:44:43.828Z",
    "dateUpdated": "2024-08-01T20:47:41.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4639 (GCVE-0-2024-4639)

Vulnerability from cvelistv5 – Published: 2024-06-25 09:15 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:34:53.804173Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:35:01.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.194Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248: Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:15:03.229Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4639",
    "datePublished": "2024-06-25T09:15:03.229Z",
    "dateReserved": "2024-05-08T00:44:42.405Z",
    "dateUpdated": "2024-08-01T20:47:41.194Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4638 (GCVE-0-2024-4638)

Vulnerability from cvelistv5 – Published: 2024-06-25 08:49 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3470A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g3470a-lte-us",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4638",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T14:17:58.104843Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:35:59.080Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3470A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248: Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T08:49:24.910Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webUploadKey",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "*  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4638",
    "datePublished": "2024-06-25T08:49:24.910Z",
    "dateReserved": "2024-05-08T00:44:40.423Z",
    "dateUpdated": "2024-08-01T20:47:41.421Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-39279 (GCVE-0-2021-39279)

Vulnerability from cvelistv5 – Published: 2021-09-07 05:40 – Updated: 2024-08-04 02:06
VLAI?
Summary
Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
https://www.moxa.com x_refsource_MISC
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:06:41.559Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.moxa.com"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-07T05:40:14",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.moxa.com"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-39279",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.moxa.com",
              "refsource": "MISC",
              "url": "https://www.moxa.com"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-39279",
    "datePublished": "2021-09-07T05:40:14",
    "dateReserved": "2021-08-18T00:00:00",
    "dateUpdated": "2024-08-04T02:06:41.559Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-39278 (GCVE-0-2021-39278)

Vulnerability from cvelistv5 – Published: 2021-09-07 05:39 – Updated: 2024-08-04 02:06
VLAI?
Summary
Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:06:40.955Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/164014"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-07T05:39:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/164014"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-39278",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://packetstormsecurity.com/files/164014",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/164014"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-39278",
    "datePublished": "2021-09-07T05:39:13",
    "dateReserved": "2021-08-18T00:00:00",
    "dateUpdated": "2024-08-04T02:06:40.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11424 (GCVE-0-2018-11424)

Vulnerability from cvelistv5 – Published: 2019-07-03 15:11 – Updated: 2024-08-05 08:10
VLAI?
Summary
There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:14.456Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-03T15:11:27",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-11424",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md",
              "refsource": "MISC",
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-11424",
    "datePublished": "2019-07-03T15:11:27",
    "dateReserved": "2018-05-24T00:00:00",
    "dateUpdated": "2024-08-05T08:10:14.456Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11425 (GCVE-0-2018-11425)

Vulnerability from cvelistv5 – Published: 2019-07-03 15:09 – Updated: 2024-08-05 08:10
VLAI?
Summary
Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:13.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-03T15:09:48",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-11425",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md",
              "refsource": "MISC",
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-11425",
    "datePublished": "2019-07-03T15:09:48",
    "dateReserved": "2018-05-24T00:00:00",
    "dateUpdated": "2024-08-05T08:10:13.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4641 (GCVE-0-2024-4641)

Vulnerability from nvd – Published: 2024-06-25 09:23 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service.
CWE
  • CWE-134 - Use of Externally-Controlled Format String
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g3470a-lte-us",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4641",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T17:38:59.616518Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:39:20.742Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.226Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to accepting a format string from an external source as an argument. An attacker could modify an externally controlled format string to cause a memory leak and denial of service."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-135",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-135: Format String Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-134",
              "description": "CWE-134: Use of Externally-Controlled Format String",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:23:30.502Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Format String Errors",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4641",
    "datePublished": "2024-06-25T09:23:30.502Z",
    "dateReserved": "2024-05-08T00:44:45.219Z",
    "dateUpdated": "2024-08-01T20:47:41.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4640 (GCVE-0-2024-4640)

Vulnerability from nvd – Published: 2024-06-25 09:19 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4640",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:15:03.203557Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:15:08.856Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.484Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to missing bounds checking on buffer operations. An attacker could write past the boundaries of allocated buffer regions in memory, causing a program crash."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100: Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:19:08.712Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n\n\n\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via sendTestEmail",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4640",
    "datePublished": "2024-06-25T09:19:08.712Z",
    "dateReserved": "2024-05-08T00:44:43.828Z",
    "dateUpdated": "2024-08-01T20:47:41.484Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4639 (GCVE-0-2024-4639)

Vulnerability from nvd – Published: 2024-06-25 09:15 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3150A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4639",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-25T13:34:53.804173Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-25T13:35:01.665Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.194Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3150A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in IPSec configuration. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248: Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T09:15:03.229Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webDelIPSec",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMoxa recommends users to implement the following mitigations if necessary: \u003c/p\u003e\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa recommends users to implement the following mitigations if necessary: \n\n  *  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4639",
    "datePublished": "2024-06-25T09:15:03.229Z",
    "dateReserved": "2024-05-08T00:44:42.405Z",
    "dateUpdated": "2024-08-01T20:47:41.194Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4638 (GCVE-0-2024-4638)

Vulnerability from nvd – Published: 2024-06-25 08:49 – Updated: 2024-08-01 20:47
VLAI?
Summary
OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command
Assigner
References
Impacted products
Vendor Product Version
Moxa OnCell G3470A-LTE Series Affected: 1.0 , ≤ 1.7.7 (custom)
Create a notification for this product.
Credits
Nikita Abramov from Positive Technologies
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:moxa:oncell_g3470a-lte-us:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "oncell_g3470a-lte-us",
            "vendor": "moxa",
            "versions": [
              {
                "lessThanOrEqual": "1.7.7",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4638",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-26T14:17:58.104843Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-26T17:35:59.080Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:47:41.421Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "OnCell G3470A-LTE Series",
          "vendor": "Moxa",
          "versions": [
            {
              "lessThanOrEqual": "1.7.7",
              "status": "affected",
              "version": "1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nikita Abramov from Positive Technologies"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
            }
          ],
          "value": "OnCell G3470A-LTE Series firmware versions v1.7.7 and prior have been identified as vulnerable due to a lack of neutralized inputs in the web key upload function. An attacker could modify the intended commands sent to target functions, which could cause malicious users to execute unauthorized commands."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248: Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-25T08:49:24.910Z",
        "orgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
        "shortName": "Moxa"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.moxa.com/en/support/product-support/security-advisory/mpsa-242550-oncell-g3470a-lte-series-multiple-web-application-vulnerabilities"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\u003cbr\u003e\u003cul\u003e\u003cli\u003eOnCell G3470A-LTE Series: Please contact Moxa Technical Support for the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.moxa.com/tw/support/technical-support\"\u003esecurity patch (v1.7.8).\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "Moxa has developed appropriate solutions to address the vulnerabilities. The solutions for affected products are shown below.\n  *  OnCell G3470A-LTE Series: Please contact Moxa Technical Support for the  security patch (v1.7.8). https://www.moxa.com/tw/support/technical-support"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "OnCell G3470A-LTE Series: Authenticated Command Injection via webUploadKey",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cul\u003e\u003cli\u003eMinimize network exposure to ensure the device is not accessible from the Internet. \u003c/li\u003e\u003cli\u003eWhen remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \u003c/li\u003e\u003cli\u003eThe starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware.\u202f\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "*  Minimize network exposure to ensure the device is not accessible from the Internet. \n  *  When remote access is required, use secure methods, such as Virtual Private Networks (VPNs). \n  *  The starting point of all the above vulnerabilities is from the web service, so it is suggested to disable web service temporarily if you completed configuration to prevent further damages from these vulnerabilities until installed patch or updated firmware."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2e0a0ee2-d866-482a-9f5e-ac03d156dbaa",
    "assignerShortName": "Moxa",
    "cveId": "CVE-2024-4638",
    "datePublished": "2024-06-25T08:49:24.910Z",
    "dateReserved": "2024-05-08T00:44:40.423Z",
    "dateUpdated": "2024-08-01T20:47:41.421Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-39279 (GCVE-0-2021-39279)

Vulnerability from nvd – Published: 2021-09-07 05:40 – Updated: 2024-08-04 02:06
VLAI?
Summary
Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
https://www.moxa.com x_refsource_MISC
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:06:41.559Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.moxa.com"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-07T05:40:14",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.moxa.com"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-39279",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain MOXA devices allow Authenticated Command Injection via /forms/web_importTFTP. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.moxa.com",
              "refsource": "MISC",
              "url": "https://www.moxa.com"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-39279",
    "datePublished": "2021-09-07T05:40:14",
    "dateReserved": "2021-08-18T00:00:00",
    "dateUpdated": "2024-08-04T02:06:41.559Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-39278 (GCVE-0-2021-39278)

Vulnerability from nvd – Published: 2021-09-07 05:39 – Updated: 2024-08-04 02:06
VLAI?
Summary
Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:06:40.955Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/164014"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-09-07T05:39:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/164014"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-39278",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain MOXA devices allow reflected XSS via the Config Import menu. This affects WAC-2004 1.7, WAC-1001 2.1, WAC-1001-T 2.1, OnCell G3470A-LTE-EU 1.7, OnCell G3470A-LTE-EU-T 1.7, TAP-323-EU-CT-T 1.3, TAP-323-US-CT-T 1.3, TAP-323-JP-CT-T 1.3, WDR-3124A-EU 2.3, WDR-3124A-EU-T 2.3, WDR-3124A-US 2.3, and WDR-3124A-US-T 2.3."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://packetstormsecurity.com/files/164014",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/164014"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-39278",
    "datePublished": "2021-09-07T05:39:13",
    "dateReserved": "2021-08-18T00:00:00",
    "dateUpdated": "2024-08-04T02:06:40.955Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11424 (GCVE-0-2018-11424)

Vulnerability from nvd – Published: 2019-07-03 15:11 – Updated: 2024-08-05 08:10
VLAI?
Summary
There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:14.456Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-03T15:11:27",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-11424",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "There is Memory corruption in the web interface of Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11425."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md",
              "refsource": "MISC",
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-002.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-11424",
    "datePublished": "2019-07-03T15:11:27",
    "dateReserved": "2018-05-24T00:00:00",
    "dateUpdated": "2024-08-05T08:10:14.456Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-11425 (GCVE-0-2018-11425)

Vulnerability from nvd – Published: 2019-07-03 15:09 – Updated: 2024-08-05 08:10
VLAI?
Summary
Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:13.826Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-03T15:09:48",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-11425",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Memory corruption issue was discovered in Moxa OnCell G3470A-LTE Series version 1.6 Build 18021314 and prior, a different vulnerability than CVE-2018-11424."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md",
              "refsource": "MISC",
              "url": "https://github.com/klsecservices/Advisories/blob/master/KL-MOXA-2018-003.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-11425",
    "datePublished": "2019-07-03T15:09:48",
    "dateReserved": "2018-05-24T00:00:00",
    "dateUpdated": "2024-08-05T08:10:13.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}