cve-2023-48363
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-09-10 09:36
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call)
communication protocol in the affected products do not
properly handle certain unorganized RPC messages. An
attacker could use this vulnerability to cause a denial of service
condition in the RPC server.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V9.1 |
Version: All versions < V9.1 SP2 UC05 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-48363", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-13T16:37:22.994141Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:21:43.194Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T21:30:34.556Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 15", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:22.958Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-48363", "datePublished": "2024-02-13T08:59:55.432Z", "dateReserved": "2023-11-15T17:20:32.751Z", "dateUpdated": "2024-09-10T09:36:22.958Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-4832
Vulnerability from cvelistv5
Published
2018-04-24 17:00
Modified
2024-08-05 05:18
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf | x_refsource_MISC | |
http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V7.1 and earlier |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T05:18:26.633Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenPCS 7 V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "OpenPCS 7 V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "OpenPCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.1 Upd5" } ] }, { "product": "OpenPCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "OpenPCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd1" } ] }, { "product": "SIMATIC BATCH V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC BATCH V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0 SP1 Upd21" } ] }, { "product": "SIMATIC BATCH V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.1 SP1 Upd16" } ] }, { "product": "SIMATIC BATCH V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 Upd10" } ] }, { "product": "SIMATIC BATCH V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP1" } ] }, { "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 15 SP1" } ] }, { "product": "SIMATIC PCS 7 V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 SP1" } ] }, { "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP1" } ] }, { "product": "SIMATIC Route Control V7.1 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V8.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC Route Control V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd1" } ] }, { "product": "SIMATIC WinCC Runtime Professional V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2 Upd2" } ] }, { "product": "SIMATIC WinCC Runtime Professional V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Upd5" } ] }, { "product": "SIMATIC WinCC V7.2 and earlier", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c WinCC 7.2 Upd 15" } ] }, { "product": "SIMATIC WinCC V7.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c WinCC 7.3 Upd 16" } ] }, { "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Upd 4" } ] }, { "product": "SPPA-T3000 Application Server", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c Service Pack R8.2 SP2" } ] } ], "datePublic": "2018-03-27T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-12T09:06:48", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-4832", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "OpenPCS 7 V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "OpenPCS 7 V8.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "OpenPCS 7 V8.1", "version": { "version_data": [ { "version_value": "All versions \u003c V8.1 Upd5" } ] } }, { "product_name": "OpenPCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "OpenPCS 7 V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 Upd1" } ] } }, { "product_name": "SIMATIC BATCH V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC BATCH V8.0", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0 SP1 Upd21" } ] } }, { "product_name": "SIMATIC BATCH V8.1", "version": { "version_data": [ { "version_value": "All versions \u003c V8.1 SP1 Upd16" } ] } }, { "product_name": "SIMATIC BATCH V8.2", "version": { "version_data": [ { "version_value": "All versions \u003c V8.2 Upd10" } ] } }, { "product_name": "SIMATIC BATCH V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 SP1" } ] } }, { "product_name": "SIMATIC NET PC Software V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Update 14" } ] } }, { "product_name": "SIMATIC NET PC Software V15", "version": { "version_data": [ { "version_value": "All versions \u003c 15 SP1" } ] } }, { "product_name": "SIMATIC PCS 7 V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V8.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V8.1", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS 7 V8.2", "version": { "version_data": [ { "version_value": "All versions \u003c V8.2 SP1" } ] } }, { "product_name": "SIMATIC PCS 7 V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 SP1" } ] } }, { "product_name": "SIMATIC Route Control V7.1 and earlier", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V8.0", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V8.1", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V8.2", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC Route Control V9.0", "version": { "version_data": [ { "version_value": "All versions \u003c V9.0 Upd1" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional V13", "version": { "version_data": [ { "version_value": "All versions \u003c V13 SP2 Upd2" } ] } }, { "product_name": "SIMATIC WinCC Runtime Professional V14", "version": { "version_data": [ { "version_value": "All versions \u003c V14 SP1 Upd5" } ] } }, { "product_name": "SIMATIC WinCC V7.2 and earlier", "version": { "version_data": [ { "version_value": "All versions \u003c WinCC 7.2 Upd 15" } ] } }, { "product_name": "SIMATIC WinCC V7.3", "version": { "version_data": [ { "version_value": "All versions \u003c WinCC 7.3 Upd 16" } ] } }, { "product_name": "SIMATIC WinCC V7.4", "version": { "version_data": [ { "version_value": "All versions \u003c V7.4 SP1 Upd 4" } ] } }, { "product_name": "SPPA-T3000 Application Server", "version": { "version_data": [ { "version_value": "All versions \u003c Service Pack R8.2 SP2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "name": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html", "refsource": "MISC", "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-4832", "datePublished": "2018-04-24T17:00:00", "dateReserved": "2018-01-02T00:00:00", "dateUpdated": "2024-08-05T05:18:26.633Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2019-19282
Vulnerability from cvelistv5
Published
2020-03-10 19:16
Modified
2024-08-05 02:09
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.
Successful exploitation requires no system privileges and no user interaction.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V8.1 |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:09:39.657Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "OpenPCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2 Upd12" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP1 Upd5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 14" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET PC Software V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V8.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V8.2", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.0", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.0 Upd4" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V13", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V13 SP2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V14", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1 Update 10" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.3", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.4 SP1 Update 14" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V7.5 SP1 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd12), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions \u003c V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions \u003c V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-131", "description": "CWE-131: Incorrect Calculation of Buffer Size", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-04-11T09:01:49.748Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19282", "datePublished": "2020-03-10T19:16:17", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:09:39.657Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-48364
Vulnerability from cvelistv5
Published
2024-02-13 08:59
Modified
2024-09-10 09:36
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | OpenPCS 7 V9.1 |
Version: All versions < V9.1 SP2 UC05 |
||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2023-48364", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-02-13T16:04:15.175349Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-05T17:21:43.053Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T21:30:34.447Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "OpenPCS 7 V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC BATCH V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PCS 7 V9.1", "vendor": "Siemens", "versions": [ { "lessThan": "V9.1 SP2 UC05", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Route Control V9.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V9.1 SP2 UC05" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V18", "vendor": "Siemens", "versions": [ { "lessThan": "V18 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC Runtime Professional V19", "vendor": "Siemens", "versions": [ { "lessThan": "V19 Update 2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.4", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V7.5", "vendor": "Siemens", "versions": [ { "lessThan": "V7.5 SP2 Update 15", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinCC V8.0", "vendor": "Siemens", "versions": [ { "lessThan": "V8.0 Update 4", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:24.190Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2023-48364", "datePublished": "2024-02-13T08:59:56.648Z", "dateReserved": "2023-11-15T17:20:32.751Z", "dateUpdated": "2024-09-10T09:36:24.190Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2018-04-24 17:29
Modified
2024-11-21 04:07
Severity ?
Summary
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf | Mitigation, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2CDCCD5-E4C7-4E52-8316-07F93E820842", "versionEndIncluding": "7.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "63F01837-6121-48E3-A18C-691AAC2800BD", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:-:*:*:*:*:*:*", "matchCriteriaId": "781DC7D3-D470-465E-8E0A-9978CB2A6454", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_1:*:*:*:*:*:*", "matchCriteriaId": "726E5A2D-97EA-415A-A251-66A975B3F98C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_2:*:*:*:*:*:*", "matchCriteriaId": "ED9B2A87-0C1E-476E-AF7E-71EAB0CECEF0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_3:*:*:*:*:*:*", "matchCriteriaId": "20D3788F-FD9E-4A0F-A7C7-843B1ED67D34", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.1:upd_4:*:*:*:*:*:*", "matchCriteriaId": "F8186041-B1D6-4460-ACA7-23494D1F0E7C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:8.2:*:*:*:*:*:*:*", "matchCriteriaId": "AF8FF2D9-B31F-46DC-AF37-E0314F3D0B32", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "3890EC18-2B5D-4B5A-8B21-6A0D1211EA98", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_batch:7.1:*:*:*:*:*:*:*", "matchCriteriaId": "9E94E0B9-2950-42CA-837E-7900F820A9F9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.0:-:*:*:*:*:*:*", "matchCriteriaId": "2C782AC7-6EAB-4F35-A646-52A4AC77E1D7", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.0:sp1_upd20:*:*:*:*:*:*", "matchCriteriaId": "3C509A97-9DD2-413A-A7ED-B30FD9E5C98F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.1:-:*:*:*:*:*:*", "matchCriteriaId": "EE12DBC8-CD75-4517-BD3B-709E98B4D280", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.1:sp1_upd14:*:*:*:*:*:*", "matchCriteriaId": "38894CBB-44DA-4690-B762-4AA497C95037", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.1:sp1_upd15:*:*:*:*:*:*", "matchCriteriaId": "59178885-4A50-4AC6-A3BE-B288A1F6B5F9", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.2:-:*:*:*:*:*:*", "matchCriteriaId": "4CAFD7F2-BB23-4E3A-A30E-78290D5EAB47", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:8.2:upd_9:*:*:*:*:*:*", "matchCriteriaId": "F043FAC3-661C-4226-AA70-7EF836DDBA55", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:*:*:*:*:*:*:*", "matchCriteriaId": "4E1EFC3E-F29B-48C5-869C-F356414C8088", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C06726E-497A-4FEF-8B4B-AF3F7B0EEFA4", "versionEndExcluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*", "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "4DFBFF6B-DBC8-451D-A235-4C7E1F0883D5", "versionEndIncluding": "7.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "3566C20F-A4A7-494F-AAD2-A11B0AD783D2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:-:*:*:*:*:*:*", "matchCriteriaId": "3EEF9BE1-F6E2-4C05-8020-4D7540882464", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*", "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*", "matchCriteriaId": "20927394-2126-48C5-B0D5-88E16B6491DA", "versionEndIncluding": "7.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "ACF395C1-AA95-4064-BDEF-9B3C30FF6B29", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "BF693D1E-091C-4CBE-957C-58C47B4E44D4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:*", "matchCriteriaId": "57073CE8-174E-429D-A721-AB14C7D16D4F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*", "matchCriteriaId": "6AAE5EBD-1B43-447D-8C19-9D3296F137F9", "versionEndExcluding": "13", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:13:-:*:*:*:*:*:*", "matchCriteriaId": "00B0EEF6-E1F9-4AEB-82AA-445D161639D3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:13:sp2_upd_1:*:*:*:*:*:*", "matchCriteriaId": "DB8D7040-0223-413F-B87F-3417CFA50BB8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:14:-:*:*:*:*:*:*", "matchCriteriaId": "17F622A5-75AE-4E5C-80CB-53C39EAE356D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:14:sp1_upd_4:*:*:*:*:*:*", "matchCriteriaId": "8D2F5FA7-6B23-413C-AF6D-CA95EDA59212", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9C72CD2-86C8-4E79-AF98-A3D58E882DED", "versionEndExcluding": "7.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:-:*:*:*:*:*:*", "matchCriteriaId": "EF42322A-1E6E-44F6-B943-DC56E87F80D2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.2:upd_14:*:*:*:*:*:*", "matchCriteriaId": "A54099D6-1E2E-4DC5-98FD-6004758C581A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:-:*:*:*:*:*:*", "matchCriteriaId": "AE3690D0-60A7-4E52-A36A-ADBA01F8D99F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.3:upd_15:*:*:*:*:*:*", "matchCriteriaId": "98174EBE-EC43-431C-B943-11B21A167A79", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*", "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*", "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_upd_3:*:*:*:*:*:*", "matchCriteriaId": "9A699260-A239-46BE-BF64-A767D4F267FC", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sppa-t3000_application_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "5CE233B0-3F20-4FA8-8E26-CCC3E21E49E1", "versionEndExcluding": "r8.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:-:*:*:*:*:*:*", "matchCriteriaId": "4EBA7673-3A24-4DF7-9D9C-4B863863083C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sppa-t3000_application_server:r8.2:sp1:*:*:*:*:*:*", "matchCriteriaId": "D0975E8C-C34F-4BD2-B4CF-41E5FBFD8A12", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C06726E-497A-4FEF-8B4B-AF3F7B0EEFA4", "versionEndExcluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:15:-:*:*:*:*:*:*", "matchCriteriaId": "7DF90C44-4AC2-4B2B-8712-30CD3DE96B22", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc_software:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A28DF82-4863-47FA-82FF-C3D63CFB1782", "versionEndExcluding": "14.0", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions \u003c V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions \u003c V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions \u003c V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd10), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions \u003c 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions \u003c V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions \u003c WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions \u003c WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en OpenPCS 7 V7.1 y anteriores (Todas las versiones), OpenPCS 7 V8.0 (Todas las versiones), OpenPCS 7 V8.1 (Todas las versiones anteriores a V8.1 Upd5), OpenPCS 7 V8. 2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a V9.0 Upd1), SIMATIC BATCH V7.1 y anteriores (Todas las versiones), SIMATIC BATCH V8.0 (Todas las versiones anteriores a V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (Todas las versiones anteriores a V8. 1 SP1 Upd16), SIMATIC BATCH V8.2 (Todas las versiones anteriores a V8.2 Upd10), SIMATIC BATCH V9.0 (Todas las versiones anteriores a V9.0 SP1), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones anteriores a 15 SP1), SIMATIC PCS 7 V7. 1 y anteriores (Todas las versiones), SIMATIC PCS 7 V8.0 (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones), SIMATIC PCS 7 V8. 2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9.0 SP1), SIMATIC Route Control V7.1 y anteriores (Todas las versiones), SIMATIC Route Control V8.0 (Todas las versiones), SIMATIC Route Control V8.1 (Todas las versiones), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones anteriores a V9. 0 Upd1), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a V14 SP1 Upd5), SIMATIC WinCC V7.2 y anteriores (Todas las versiones anteriores a WinCC 7. 2 Upd 15), SIMATIC WinCC V7.3 (Todas las versiones anteriores a WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Upd 4), SPPA-T3000 Application Server (Todas las versiones anteriores a Service Pack R8.2 SP2). Los mensajes especialmente dise\u00f1ados enviados al servicio RPC de los productos afectados podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio en la funcionalidad de comunicaci\u00f3n remota y local de los productos afectados. Es necesario reiniciar el sistema para recuperar la funcionalidad de comunicaci\u00f3n remota y local. Tenga en cuenta que un atacante necesita tener acceso a la red del servidor de aplicaciones para poder explotar esta vulnerabilidad. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda ninguna explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad" } ], "id": "CVE-2018-4832", "lastModified": "2024-11-21T04:07:32.557", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-04-24T17:29:00.227", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" }, { "source": "productcert@siemens.com", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://packetstormsecurity.com/files/155665/Siemens-Security-Advisory-SPPA-T3000-Code-Execution.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348629.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-451445.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2020-03-10 20:15
Modified
2024-11-21 04:34
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions < V8.2 Upd12), SIMATIC BATCH V9.0 (All versions < V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions < V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions < V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.
Successful exploitation requires no system privileges and no user interaction.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:openpcs_7:9.0:-:*:*:*:*:*:*", "matchCriteriaId": "1CBF717A-B2D4-459C-894A-65622570645D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:openpcs_7:9.0_update_1:*:*:*:*:*:*:*", "matchCriteriaId": "957DDF70-1837-4E92-A707-944AD6ED4304", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:-:*:*:*:*:*:*", "matchCriteriaId": "E54F6E83-C353-44FB-9F37-C03DA344A5DC", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "3E19D98B-B40A-4589-8C26-7722C25EEC63", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_1:*:*:*:*:*:*", "matchCriteriaId": "85CDD274-B2B4-4DB0-9917-C16B5D900006", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_2:*:*:*:*:*:*", "matchCriteriaId": "0B435D51-FFA2-4F19-9B51-404BB37D7F0D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_3:*:*:*:*:*:*", "matchCriteriaId": "AFBBC7D6-D1D4-452E-A744-B490CF002354", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:9.0:sp1_update_4:*:*:*:*:*:*", "matchCriteriaId": "98BC62E3-4C0B-481A-9274-B9C785F8FDC5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*", "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_net_pc:16:-:*:*:*:*:*:*", "matchCriteriaId": "496E3C43-5DA8-4983-8AC6-0F32454E22F3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*", "matchCriteriaId": "858628AC-EA69-4D72-AE23-77A4A8DE2547", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*", "matchCriteriaId": "F4A75F15-8F47-4348-A85C-D94BBA8F9992", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:-:*:*:*:*:*:*", "matchCriteriaId": "A42E3FB0-6C66-4702-BDC8-39EEA54B5C0F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:sp1:*:*:*:*:*:*", "matchCriteriaId": "7AA0E077-AB19-473B-9454-8FED7188A2C4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:9.0:sp2:*:*:*:*:*:*", "matchCriteriaId": "19EA3CAD-E7CB-412F-A2EA-86A81EC25425", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*", "matchCriteriaId": "885BA05F-BD8F-4DE9-BDD3-6C2C76418B05", "versionEndExcluding": "9.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:9.0:-:*:*:*:*:*:*", "matchCriteriaId": "57073CE8-174E-429D-A721-AB14C7D16D4F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:-:*:*:*:*:*:*", "matchCriteriaId": "3B0BD5DE-C6EF-4B89-831B-DA34DB0D68F6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1:*:*:*:*:*:*", "matchCriteriaId": "2637C346-8AAF-481F-AFB0-BAD4254D14F4", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_1:*:*:*:*:*:*", "matchCriteriaId": "9589FF11-4F9B-40F6-A6C6-55405B9EE351", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_10:*:*:*:*:*:*", "matchCriteriaId": "1DB57B3A-C3B6-4E61-9DAE-B12CEA8CD093", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_11:*:*:*:*:*:*", "matchCriteriaId": "EA6B2933-9C44-480C-96DC-6DF8C88950AF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_12:*:*:*:*:*:*", "matchCriteriaId": "45097864-DD87-4587-997B-792F0175472B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_13:*:*:*:*:*:*", "matchCriteriaId": "2FB24A30-0F93-430D-817E-05E4594C8823", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_2:*:*:*:*:*:*", "matchCriteriaId": "25237B9A-2E51-4F17-BD75-04D245CCC51D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_3:*:*:*:*:*:*", "matchCriteriaId": "90643D49-9EFC-4B9A-99C8-266135DF2E00", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_4:*:*:*:*:*:*", "matchCriteriaId": "AC4D7B24-91FF-4891-ABC3-683A6C72ADDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_5:*:*:*:*:*:*", "matchCriteriaId": "D1DD77A4-1716-4793-AD73-79D04E3D2AEE", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_6:*:*:*:*:*:*", "matchCriteriaId": "5E667123-6909-4DF2-8CEB-6E87E9FC48BC", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_7:*:*:*:*:*:*", "matchCriteriaId": "04A5C76A-5D6D-47F8-BEF7-503F9A89AD18", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_8:*:*:*:*:*:*", "matchCriteriaId": "E776629C-904C-49D6-BF3F-8520FA7D5DFA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:sp1_update_9:*:*:*:*:*:*", "matchCriteriaId": "805DAA15-03A3-4F63-90F7-EA130E5136F2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:-:*:*:*:*:*:*", "matchCriteriaId": "E79DA14E-419C-49BA-8E4F-2907E1D8937F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:-:*:*:*:*:*", "matchCriteriaId": "00A48A8E-C112-4778-8A7B-2386E88A0177", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5.1:-:*:*:*:*:*:*", "matchCriteriaId": "D3D10C7E-5FD5-4B37-884B-B450DE5F800B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:-:*:*:*:*:*:*", "matchCriteriaId": "0D9FE447-2090-47D2-8667-5DC7605089BB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:13:sp1:*:*:*:*:*:*", "matchCriteriaId": "BB4FFADC-51F0-439F-9F80-D2B2614FFC39", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:14.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "CE5A7162-F1B5-4E74-99D6-4108AC4C49FC", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "50B77C2A-4D66-4407-8CA4-99C43ED72DDB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_1:*:*:*:*:*:*", "matchCriteriaId": "9794ED7E-EB17-4C95-B900-840A48758F03", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_2:*:*:*:*:*:*", "matchCriteriaId": "57E82CFE-4191-4055-A0BA-EAB7BE96D947", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_3:*:*:*:*:*:*", "matchCriteriaId": "C4DBBDAA-BCAE-4B63-BDFC-3DD70DAD9B7D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:15.1:update_4:*:*:*:*:*:*", "matchCriteriaId": "B5AF87C6-F8D6-4462-9DF5-B9D301002B1C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:16:-:*:*:*:*:*:*", "matchCriteriaId": "A4316924-9EF8-4835-A2E4-0C81F4DE473D", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V8.1 (All versions), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions \u003c V9.0 Upd3), SIMATIC BATCH V8.1 (All versions), SIMATIC BATCH V8.2 (All versions \u003c V8.2 Upd12), SIMATIC BATCH V9.0 (All versions \u003c V9.0 SP1 Upd5), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions \u003c V9.0 SP3), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions \u003c V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (All versions \u003c V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15.1 (All versions \u003c V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (All versions \u003c V16 Update 1), SIMATIC WinCC V7.3 (All versions), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 1). Through specially crafted messages, when encrypted communication is enabled, an attacker with network access could use the vulnerability to compromise the availability of the system by causing a Denial-of-Service condition.\nSuccessful exploitation requires no system privileges and no user interaction." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en OpenPCS 7 V8.1 (Todas las versiones), OpenPCS 7 V8.2 (Todas las versiones), OpenPCS 7 V9.0 (Todas las versiones anteriores a V9.0 Upd3), SIMATIC BATCH V8.1 (Todas las versiones), SIMATIC BATCH V8.2 (Todas las versiones), SIMATIC BATCH V9.0 (Todas las versiones anteriores a V9. 0 SP1 Upd5), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC PCS 7 V8.1 (Todas las versiones), SIMATIC PCS 7 V8.2 (Todas las versiones), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a V9. 0 SP3), SIMATIC Route Control V8.1 (Todas las versiones), SIMATIC Route Control V8.2 (Todas las versiones), SIMATIC Route Control V9.0 (Todas las versiones anteriores a V9.0 Upd4), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones anteriores a V14 SP1 Update 10), SIMATIC WinCC (TIA Portal) V15. 1 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC WinCC (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 1), SIMATIC WinCC V7.3 (Todas las versiones), SIMATIC WinCC V7.4 (Todas las versiones anteriores a V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a V7.5 SP1 Update 1). A trav\u00e9s de mensajes especialmente dise\u00f1ados, cuando la comunicaci\u00f3n cifrada est\u00e1 habilitada, un atacante con acceso a la red podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del sistema causando una condici\u00f3n de denegaci\u00f3n de servicio. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario" } ], "id": "CVE-2019-19282", "lastModified": "2024-11-21T04:34:29.480", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2020-03-10T20:15:18.960", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-270778.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-131" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2024-02-13 09:15
Modified
2024-11-21 08:31
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | openpcs_7 | * | |
siemens | simatic_batch | * | |
siemens | simatic_pcs_7 | * | |
siemens | simatic_route_control | * | |
siemens | simatic_wincc | 7.4 | |
siemens | simatic_wincc | 7.5 | |
siemens | simatic_wincc | 8.0 | |
siemens | simatic_wincc_runtime_professional | * | |
siemens | simatic_wincc_runtime_professional | 19 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1350C78-30BE-4FA0-BE95-7A897C0D1927", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA5C1EC7-2F78-400D-9F85-FCEF71C4F1D5", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDA0756E-97B0-4896-BED4-44E86D6C76DE", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0AF2A6B-2A46-4147-AB1C-6E4DD71CD8C2", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*", "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*", "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "E57C7724-EEDA-4F6E-8634-65B10C3319A2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*", "matchCriteriaId": "872A881A-22F6-47E0-99ED-A83D9F77DB02", "versionEndIncluding": "18", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*", "matchCriteriaId": "18D1C8AC-6A32-4ABB-A52D-58B774A5C9BE", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) communication protocol in the affected products do not properly handle certain malformed RPC messages. An attacker could use this vulnerability to cause a denial of service condition in the RPC server." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nOpenPCS 7 V9.1 (todas las versiones), \nSIMATIC BATCH V9.1 (todas las versiones), \nSIMATIC PCS 7 V9.1 (todas las versiones), \nSIMATIC Route Control V9.1 (todas las versiones), \nSIMATIC WinCC Runtime Professional V18 (todas las versiones), \nSIMATIC WinCC Runtime Professional V19 (todas las versiones), \nSIMATIC WinCC V7.4 (todas las versiones), \nSIMATIC WinCC V7.5 (todas las versiones \u0026lt; V7.5 SP2 Update 15), \nSIMATIC WinCC V8.0 (Todas las versiones " } ], "id": "CVE-2023-48364", "lastModified": "2024-11-21T08:31:34.503", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "ADJACENT", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-02-13T09:15:45.980", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-02-13 09:15
Modified
2024-11-21 08:31
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability has been identified in OpenPCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions < V8.0 Update 4). The implementation of the RPC (Remote Procedure call)
communication protocol in the affected products do not
properly handle certain unorganized RPC messages. An
attacker could use this vulnerability to cause a denial of service
condition in the RPC server.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | openpcs_7 | * | |
siemens | simatic_batch | * | |
siemens | simatic_pcs_7 | * | |
siemens | simatic_route_control | * | |
siemens | simatic_wincc | 7.4 | |
siemens | simatic_wincc | 7.5 | |
siemens | simatic_wincc | 8.0 | |
siemens | simatic_wincc_runtime_professional | * | |
siemens | simatic_wincc_runtime_professional | 19 |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:openpcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "F1350C78-30BE-4FA0-BE95-7A897C0D1927", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_batch:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA5C1EC7-2F78-400D-9F85-FCEF71C4F1D5", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDA0756E-97B0-4896-BED4-44E86D6C76DE", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_route_control:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0AF2A6B-2A46-4147-AB1C-6E4DD71CD8C2", "versionEndIncluding": "9.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*", "matchCriteriaId": "F64B795A-7E66-49AE-BE40-E8EEAC12D280", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*", "matchCriteriaId": "7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "E57C7724-EEDA-4F6E-8634-65B10C3319A2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*", "matchCriteriaId": "872A881A-22F6-47E0-99ED-A83D9F77DB02", "versionEndIncluding": "18", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_professional:19:*:*:*:*:*:*:*", "matchCriteriaId": "18D1C8AC-6A32-4ABB-A52D-58B774A5C9BE", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in OpenPCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 15), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 4). The implementation of the RPC (Remote Procedure call) \r\ncommunication protocol in the affected products do not \r\nproperly handle certain unorganized RPC messages. An \r\nattacker could use this vulnerability to cause a denial of service \r\ncondition in the RPC server." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en: \nOpenPCS 7 V9.1 (todas las versiones), \nSIMATIC BATCH V9.1 (todas las versiones), \nSIMATIC PCS 7 V9.1 (todas las versiones), \nSIMATIC Route Control V9.1 (todas las versiones), \nSIMATIC WinCC Runtime Professional V18 (todas las versiones), \nSIMATIC WinCC Runtime Professional V19 (todas las versiones), \nSIMATIC WinCC V7.4 (todas las versiones), \nSIMATIC WinCC V7.5 (todas las versiones \u0026lt; V7.5 SP2 Update 15), \nSIMATIC WinCC V8.0 (Todas las versiones " } ], "id": "CVE-2023-48363", "lastModified": "2024-11-21T08:31:34.337", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "ADJACENT", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2024-02-13T09:15:45.763", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-753746.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }