Search criteria

27 vulnerabilities found for osprey_pump_controller_firmware by propumpservice

FKIE_CVE-2023-28648

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:55
Summary
Osprey Pump Controller version 1.01 inputs passed to a GET parameter are not properly sanitized before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user's browser session in context of an affected site.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 inputs passed to a GET parameter are not properly sanitized before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user\u0027s browser session in context of an affected site."
    }
  ],
  "id": "CVE-2023-28648",
  "lastModified": "2024-11-21T07:55:44.227",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:11.390",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-28654

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:55
Summary
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device."
    }
  ],
  "id": "CVE-2023-28654",
  "lastModified": "2024-11-21T07:55:44.897",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:11.443",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-798"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-28712

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:55
Summary
Osprey Pump Controller version 1.01 contains an unauthenticated command injection vulnerability that could allow system access with www-data permissions.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 contains an unauthenticated command injection vulnerability that could allow system access with www-data permissions. "
    }
  ],
  "id": "CVE-2023-28712",
  "lastModified": "2024-11-21T07:55:51.450",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 8.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 4.2,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:11.520",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-28398

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:54
Summary
Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller."
    }
  ],
  "id": "CVE-2023-28398",
  "lastModified": "2024-11-21T07:54:59.510",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:11.003",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-28718

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:55
Summary
Osprey Pump Controller version 1.01 allows users to perform certain actions via HTTP requests without performing any checks to verify the requests. This may allow an attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 allows users to perform certain actions via HTTP requests without performing any checks to verify the requests. This may allow an attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
    }
  ],
  "id": "CVE-2023-28718",
  "lastModified": "2024-11-21T07:55:52.073",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.1,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:11.587",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-28375

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:54
Summary
Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated file disclosure. Using a GET parameter, attackers can disclose arbitrary files on the affected device and disclose sensitive and system information.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated file disclosure. Using a GET parameter, attackers can disclose arbitrary files on the affected device and disclose sensitive and system information."
    }
  ],
  "id": "CVE-2023-28375",
  "lastModified": "2024-11-21T07:54:57.003",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:10.950",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-552"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-27886

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:53
Summary
Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script."
    }
  ],
  "id": "CVE-2023-27886",
  "lastModified": "2024-11-21T07:53:37.923",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:10.813",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-27394

Vulnerability from fkie_nvd - Published: 2023-03-28 21:15 - Updated: 2024-11-21 07:52
Summary
Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts."
    }
  ],
  "id": "CVE-2023-27394",
  "lastModified": "2024-11-21T07:52:49.157",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T21:15:10.750",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-78"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2023-28395

Vulnerability from fkie_nvd - Published: 2023-03-28 20:15 - Updated: 2024-11-21 07:54
Summary
Osprey Pump Controller version 1.01 is vulnerable to a weak session token generation algorithm that can be predicted and can aid in authentication and authorization bypass. This may allow an attacker to hijack a session by predicting the session id and gain unauthorized access to the product.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:propumpservice:osprey_pump_controller_firmware:1.01:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B10E95-86EC-4C15-83B4-73B7384A5C43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:propumpservice:osprey_pump_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16780CFE-7F41-4A59-8C5C-CFB6AA7D22E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Osprey Pump Controller version 1.01 is vulnerable to a weak session token generation algorithm that can be predicted and can aid in authentication and authorization bypass. This may allow an attacker to hijack a session by predicting the session id and gain unauthorized access to the product."
    }
  ],
  "id": "CVE-2023-28395",
  "lastModified": "2024-11-21T07:54:59.197",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.5,
        "source": "ics-cert@hq.dhs.gov",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2023-03-28T20:15:15.530",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-338"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2023-28712 (GCVE-0-2023-28712)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:10 – Updated: 2025-01-16 21:37
VLAI?
Title
CVE-2023-28712
Summary
Osprey Pump Controller version 1.01 contains an unauthenticated command injection vulnerability that could allow system access with www-data permissions.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.682Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28712",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:56:02.419411Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:37:40.431Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 contains an unauthenticated command injection vulnerability that could allow system access with www-data permissions. "
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:10:26.133Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28712",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28712"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28712",
    "datePublished": "2023-03-28T20:10:26.133Z",
    "dateReserved": "2023-03-21T21:17:06.907Z",
    "dateUpdated": "2025-01-16T21:37:40.431Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28718 (GCVE-0-2023-28718)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:09 – Updated: 2025-01-16 21:37
VLAI?
Title
CVE-2023-28718
Summary
Osprey Pump Controller version 1.01 allows users to perform certain actions via HTTP requests without performing any checks to verify the requests. This may allow an attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.859Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28718",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:30:52.679367Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:37:47.648Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 allows users to perform certain actions via HTTP requests without performing any checks to verify the requests. This may allow an attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-352 Cross-Site Request Forgery (CSRF)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:09:15.958Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28718",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28718"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28718",
    "datePublished": "2023-03-28T20:09:15.958Z",
    "dateReserved": "2023-03-21T21:17:06.902Z",
    "dateUpdated": "2025-01-16T21:37:47.648Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28398 (GCVE-0-2023-28398)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:08 – Updated: 2025-01-16 21:37
VLAI?
Title
CVE-2023-28398
Summary
Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.301Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28398",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:33.591472Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:37:57.274Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:08:09.624Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28398",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28398"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28398",
    "datePublished": "2023-03-28T20:08:09.624Z",
    "dateReserved": "2023-03-21T21:17:06.897Z",
    "dateUpdated": "2025-01-16T21:37:57.274Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28648 (GCVE-0-2023-28648)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:06 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28648
Summary
Osprey Pump Controller version 1.01 inputs passed to a GET parameter are not properly sanitized before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user's browser session in context of an affected site.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.561Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28648",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:56:05.294118Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:05.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 inputs passed to a GET parameter are not properly sanitized before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user\u0027s browser session in context of an affected site."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:06:56.715Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28648",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28648"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28648",
    "datePublished": "2023-03-28T20:06:56.715Z",
    "dateReserved": "2023-03-21T21:17:06.892Z",
    "dateUpdated": "2025-01-16T21:38:05.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27394 (GCVE-0-2023-27394)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:05 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-27394
Summary
Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.401Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27394",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:36.241791Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:12.795Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:05:21.304Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-27394",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-27394"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-27394",
    "datePublished": "2023-03-28T20:05:21.304Z",
    "dateReserved": "2023-03-21T21:17:06.888Z",
    "dateUpdated": "2025-01-16T21:38:12.795Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27886 (GCVE-0-2023-27886)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:04 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-27886
Summary
Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:23:29.843Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:39.175061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:19.554Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:04:07.830Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-27886",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-27886"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-27886",
    "datePublished": "2023-03-28T20:04:07.830Z",
    "dateReserved": "2023-03-21T21:17:06.883Z",
    "dateUpdated": "2025-01-16T21:38:19.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28654 (GCVE-0-2023-28654)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:03 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28654
Summary
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.597Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28654",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:41.904280Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:27.722Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-259 Use of Hard-Coded Password",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:03:03.238Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28654",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28654"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28654",
    "datePublished": "2023-03-28T20:03:03.238Z",
    "dateReserved": "2023-03-21T21:17:06.877Z",
    "dateUpdated": "2025-01-16T21:38:27.722Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28375 (GCVE-0-2023-28375)

Vulnerability from cvelistv5 – Published: 2023-03-28 20:02 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28375
Summary
Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated file disclosure. Using a GET parameter, attackers can disclose arbitrary files on the affected device and disclose sensitive and system information.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.071Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28375",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:56:07.868425Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:35.314Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated file disclosure. Using a GET parameter, attackers can disclose arbitrary files on the affected device and disclose sensitive and system information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:02:00.775Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28375",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28375"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28375",
    "datePublished": "2023-03-28T20:02:00.775Z",
    "dateReserved": "2023-03-21T21:17:06.873Z",
    "dateUpdated": "2025-01-16T21:38:35.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28395 (GCVE-0-2023-28395)

Vulnerability from cvelistv5 – Published: 2023-03-28 19:59 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28395
Summary
Osprey Pump Controller version 1.01 is vulnerable to a weak session token generation algorithm that can be predicted and can aid in authentication and authorization bypass. This may allow an attacker to hijack a session by predicting the session id and gain unauthorized access to the product.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.093Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28395",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:30:56.055672Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:44.402Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable to a weak session token generation algorithm that can be predicted and can aid in authentication and authorization bypass. This may allow an attacker to hijack a session by predicting the session id and gain unauthorized access to the product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-331 Insufficient Entropy",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T19:59:29.953Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28395",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28395"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28395",
    "datePublished": "2023-03-28T19:59:29.953Z",
    "dateReserved": "2023-03-21T21:17:06.865Z",
    "dateUpdated": "2025-01-16T21:38:44.402Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28712 (GCVE-0-2023-28712)

Vulnerability from nvd – Published: 2023-03-28 20:10 – Updated: 2025-01-16 21:37
VLAI?
Title
CVE-2023-28712
Summary
Osprey Pump Controller version 1.01 contains an unauthenticated command injection vulnerability that could allow system access with www-data permissions.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.682Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28712",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:56:02.419411Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:37:40.431Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 contains an unauthenticated command injection vulnerability that could allow system access with www-data permissions. "
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:10:26.133Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28712",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28712"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28712",
    "datePublished": "2023-03-28T20:10:26.133Z",
    "dateReserved": "2023-03-21T21:17:06.907Z",
    "dateUpdated": "2025-01-16T21:37:40.431Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28718 (GCVE-0-2023-28718)

Vulnerability from nvd – Published: 2023-03-28 20:09 – Updated: 2025-01-16 21:37
VLAI?
Title
CVE-2023-28718
Summary
Osprey Pump Controller version 1.01 allows users to perform certain actions via HTTP requests without performing any checks to verify the requests. This may allow an attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.859Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28718",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:30:52.679367Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:37:47.648Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 allows users to perform certain actions via HTTP requests without performing any checks to verify the requests. This may allow an attacker to perform certain actions with administrative privileges if a logged-in user visits a malicious website."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-352 Cross-Site Request Forgery (CSRF)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:09:15.958Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28718",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28718"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28718",
    "datePublished": "2023-03-28T20:09:15.958Z",
    "dateReserved": "2023-03-21T21:17:06.902Z",
    "dateUpdated": "2025-01-16T21:37:47.648Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28398 (GCVE-0-2023-28398)

Vulnerability from nvd – Published: 2023-03-28 20:08 – Updated: 2025-01-16 21:37
VLAI?
Title
CVE-2023-28398
Summary
Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.301Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28398",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:33.591472Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:37:57.274Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 could allow an unauthenticated user to create an account and bypass authentication, thereby gaining unauthorized access to the system. A threat actor could exploit this vulnerability to create a user account without providing valid credentials. A threat actor who successfully exploits this vulnerability could gain access to the pump controller and cause disruption in operation, modify data, or shut down the controller."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-288 Authentication Bypass Using an Alternate Path or Channel",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:08:09.624Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28398",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28398"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28398",
    "datePublished": "2023-03-28T20:08:09.624Z",
    "dateReserved": "2023-03-21T21:17:06.897Z",
    "dateUpdated": "2025-01-16T21:37:57.274Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28648 (GCVE-0-2023-28648)

Vulnerability from nvd – Published: 2023-03-28 20:06 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28648
Summary
Osprey Pump Controller version 1.01 inputs passed to a GET parameter are not properly sanitized before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user's browser session in context of an affected site.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.561Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28648",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:56:05.294118Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:05.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 inputs passed to a GET parameter are not properly sanitized before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user\u0027s browser session in context of an affected site."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:06:56.715Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28648",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28648"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28648",
    "datePublished": "2023-03-28T20:06:56.715Z",
    "dateReserved": "2023-03-21T21:17:06.892Z",
    "dateUpdated": "2025-01-16T21:38:05.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27394 (GCVE-0-2023-27394)

Vulnerability from nvd – Published: 2023-03-28 20:05 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-27394
Summary
Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:09:43.401Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27394",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:36.241791Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:12.795Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP GET parameter called by DataLogView.php, EventsView.php and AlarmsView.php scripts."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:05:21.304Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-27394",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-27394"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-27394",
    "datePublished": "2023-03-28T20:05:21.304Z",
    "dateReserved": "2023-03-21T21:17:06.888Z",
    "dateUpdated": "2025-01-16T21:38:12.795Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-27886 (GCVE-0-2023-27886)

Vulnerability from nvd – Published: 2023-03-28 20:04 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-27886
Summary
Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:23:29.843Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-27886",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:39.175061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:19.554Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated OS command injection vulnerability. This can be exploited to inject and execute arbitrary shell commands through a HTTP POST parameter called by index.php script."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:04:07.830Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-27886",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-27886"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-27886",
    "datePublished": "2023-03-28T20:04:07.830Z",
    "dateReserved": "2023-03-21T21:17:06.883Z",
    "dateUpdated": "2025-01-16T21:38:19.554Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28654 (GCVE-0-2023-28654)

Vulnerability from nvd – Published: 2023-03-28 20:03 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28654
Summary
Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T13:43:23.597Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28654",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:58:41.904280Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:27.722Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 has a hidden administrative account that has the hardcoded password that allows full access to the web management interface configuration. The user is not visible in Usernames and Passwords menu list of the application and the password cannot be changed through any normal operation of the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-259 Use of Hard-Coded Password",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:03:03.238Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28654",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28654"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28654",
    "datePublished": "2023-03-28T20:03:03.238Z",
    "dateReserved": "2023-03-21T21:17:06.877Z",
    "dateUpdated": "2025-01-16T21:38:27.722Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28375 (GCVE-0-2023-28375)

Vulnerability from nvd – Published: 2023-03-28 20:02 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28375
Summary
Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated file disclosure. Using a GET parameter, attackers can disclose arbitrary files on the affected device and disclose sensitive and system information.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.071Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28375",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:56:07.868425Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:35.314Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable to an unauthenticated file disclosure. Using a GET parameter, attackers can disclose arbitrary files on the affected device and disclose sensitive and system information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-598 Use of GET Request Method With Sensitive Query Strings",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T20:02:00.775Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28375",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28375"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28375",
    "datePublished": "2023-03-28T20:02:00.775Z",
    "dateReserved": "2023-03-21T21:17:06.873Z",
    "dateUpdated": "2025-01-16T21:38:35.314Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-28395 (GCVE-0-2023-28395)

Vulnerability from nvd – Published: 2023-03-28 19:59 – Updated: 2025-01-16 21:38
VLAI?
Title
CVE-2023-28395
Summary
Osprey Pump Controller version 1.01 is vulnerable to a weak session token generation algorithm that can be predicted and can aid in authentication and authorization bypass. This may allow an attacker to hijack a session by predicting the session id and gain unauthorized access to the product.
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.093Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28395",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-16T20:30:56.055672Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-16T21:38:44.402Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Osprey Pump Controller",
          "vendor": "ProPump and Controls, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "1.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Osprey Pump Controller version 1.01 is vulnerable to a weak session token generation algorithm that can be predicted and can aid in authentication and authorization bypass. This may allow an attacker to hijack a session by predicting the session id and gain unauthorized access to the product."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-331 Insufficient Entropy",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-03-28T19:59:29.953Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-06"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-28395",
      "x_generator": {
        "engine": "VINCE 2.0.7",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-28395"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2023-28395",
    "datePublished": "2023-03-28T19:59:29.953Z",
    "dateReserved": "2023-03-21T21:17:06.865Z",
    "dateUpdated": "2025-01-16T21:38:44.402Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}