Search criteria
3 vulnerabilities found for platform_engineering_tools by abb
FKIE_CVE-2022-0010
Vulnerability from fkie_nvd - Published: 2023-05-22 08:15 - Updated: 2024-11-21 06:37
Severity
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.
An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes.
This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| abb | platform_engineering_tools | * | |
| abb | qcs_800xa_firmware | * | |
| abb | qcs_800xa_firmware | 5.1.0 | |
| abb | qcs_800xa | - | |
| abb | qcs_ac450_firmware | * | |
| abb | qcs_ac450_firmware | 6.1.0 | |
| abb | qcs_ac450 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:abb:platform_engineering_tools:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B0469275-C1B5-45EE-B4A9-DE1F500E04C6",
"versionEndIncluding": "2.3.0",
"versionStartIncluding": "1.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:qcs_800xa_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F25CD2B4-140C-49C4-BEBD-9021CAD12FE9",
"versionEndIncluding": "5.1.0",
"versionStartIncluding": "1.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:abb:qcs_800xa_firmware:5.1.0:sp2:*:*:*:*:*:*",
"matchCriteriaId": "32217B3E-F886-48A1-8987-A92DA4E54A9A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:qcs_800xa:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44BDFBF8-88D6-45D9-965F-85CFD002F316",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:abb:qcs_ac450_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "24106F4D-2DF1-417E-9FF1-DD212E1F6F27",
"versionEndIncluding": "6.1.0",
"versionStartIncluding": "1.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:abb:qcs_ac450_firmware:6.1.0:sp2:*:*:*:*:*:*",
"matchCriteriaId": "03FA9720-A525-4F4B-9486-C346C258B4DE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:abb:qcs_ac450:-:*:*:*:*:*:*:*",
"matchCriteriaId": "79CCB4FA-2651-4E96-925F-772E3EAFA593",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.\n\n\nAn attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. \n\nThis issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.\n\n"
}
],
"id": "CVE-2022-0010",
"lastModified": "2024-11-21T06:37:48.507",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-05-22T08:15:08.920",
"references": [
{
"source": "cybersecurity@ch.abb.com",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUS221709\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.108646530.1437951308.1684739395-1142547495.1678209228"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUS221709\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.108646530.1437951308.1684739395-1142547495.1678209228"
}
],
"sourceIdentifier": "cybersecurity@ch.abb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "cybersecurity@ch.abb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2022-0010 (GCVE-0-2022-0010)
Vulnerability from cvelistv5 – Published: 2023-05-22 07:22 – Updated: 2025-01-21 21:43
VLAI
Title
QCS 800xA Vulnerability identified in system log files
Summary
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.
An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes.
This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:18:41.542Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUS221709\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.108646530.1437951308.1684739395-1142547495.1678209228"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-0010",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-21T21:42:53.592481Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-21T21:43:10.565Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QCS 800xA",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "6.1SP2",
"status": "affected",
"version": "1.0;0",
"versionType": "patch"
}
]
},
{
"defaultStatus": "unaffected",
"product": "QCS AC450",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "5.1SP2",
"status": "affected",
"version": "1.0;0",
"versionType": "patch"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Platform Engineering Tools",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "2.3.0",
"status": "affected",
"version": "1.0:0",
"versionType": "patch"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. \u003c/span\u003e\n\n\u003cp\u003eThis issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.\u003c/p\u003e"
}
],
"value": "Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.\n\n\nAn attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. \n\nThis issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-22T07:22:51.662Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUS221709\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.108646530.1437951308.1684739395-1142547495.1678209228"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "QCS 800xA Vulnerability identified in system log files",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-0010",
"datePublished": "2023-05-22T07:22:51.662Z",
"dateReserved": "2021-12-13T11:17:36.576Z",
"dateUpdated": "2025-01-21T21:43:10.565Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-0010 (GCVE-0-2022-0010)
Vulnerability from nvd – Published: 2023-05-22 07:22 – Updated: 2025-01-21 21:43
VLAI
Title
QCS 800xA Vulnerability identified in system log files
Summary
Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.
An attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes.
This issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T23:18:41.542Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUS221709\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.108646530.1437951308.1684739395-1142547495.1678209228"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-0010",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-21T21:42:53.592481Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-21T21:43:10.565Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "QCS 800xA",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "6.1SP2",
"status": "affected",
"version": "1.0;0",
"versionType": "patch"
}
]
},
{
"defaultStatus": "unaffected",
"product": "QCS AC450",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "5.1SP2",
"status": "affected",
"version": "1.0;0",
"versionType": "patch"
}
]
},
{
"defaultStatus": "unaffected",
"product": "Platform Engineering Tools",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "2.3.0",
"status": "affected",
"version": "1.0:0",
"versionType": "patch"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. \u003c/span\u003e\n\n\u003cp\u003eThis issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.\u003c/p\u003e"
}
],
"value": "Insertion of Sensitive Information into Log File vulnerability in ABB QCS 800xA, ABB QCS AC450, ABB Platform Engineering Tools.\n\n\nAn attacker, who already has local access to the QCS nodes, could successfully obtain the password for a system user account. Using this information, the attacker could have the potential to exploit this vulnerability to gain control of system nodes. \n\nThis issue affects QCS 800xA: from 1.0;0 through 6.1SP2; QCS AC450: from 1.0;0 through 5.1SP2; Platform Engineering Tools: from 1.0:0 through 2.3.0.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-05-22T07:22:51.662Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=3BUS221709\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\u0026_ga=2.108646530.1437951308.1684739395-1142547495.1678209228"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "QCS 800xA Vulnerability identified in system log files",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2022-0010",
"datePublished": "2023-05-22T07:22:51.662Z",
"dateReserved": "2021-12-13T11:17:36.576Z",
"dateUpdated": "2025-01-21T21:43:10.565Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}