Search criteria
3 vulnerabilities found for power_xpert_meter_4000_firmware by eaton
FKIE_CVE-2018-16158
Vulnerability from fkie_nvd - Published: 2018-08-30 05:29 - Updated: 2024-11-21 03:52
Severity ?
Summary
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf | Vendor Advisory | |
| cve@mitre.org | https://www.ctrlu.net/vuln/0006.html | Exploit, Third Party Advisory | |
| nvd@nist.gov | https://github.com/BrianWGray/msf/blob/master/exploits/linux/ssh/eaton_known_privkey.rb | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.ctrlu.net/vuln/0006.html | Exploit, Third Party Advisory |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:eaton:power_xpert_meter_4000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDAC95FB-A735-4A85-9D74-0BDDDA189F66",
"versionEndExcluding": "13.4.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:eaton:power_xpert_meter_4000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E4680466-AC11-4F70-AF35-4D58678E6B05",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:eaton:power_xpert_meter_6000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49229544-8736-453A-B25F-6CDF79A41281",
"versionEndExcluding": "13.4.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:eaton:power_xpert_meter_6000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00E2537C-A7D4-41F2-8C24-BB17EE097372",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:eaton:power_xpert_meter_8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "40AD9263-481A-4069-ACC8-BE3A5BF5F0D7",
"versionEndExcluding": "13.4.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:eaton:power_xpert_meter_8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "082E02C0-E446-4928-9723-9924B72160F8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers\u0027 installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option."
},
{
"lang": "es",
"value": "Los dispositivos Eaton Power Xpert Meter 4000, 6000 y 8000 en versiones anteriores a la 13.4.0.10 tienen una \u00fanica clave privada SSH en las diferentes instalaciones de clientes y no restringen correctamente el acceso a dicha clave, lo que facilita que atacantes remotos realicen inicios de sesi\u00f3n SSH (a uid 0) mediante la opci\u00f3n PubkeyAuthentication."
}
],
"id": "CVE-2018-16158",
"lastModified": "2024-11-21T03:52:11.420",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-08-30T05:29:00.443",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"source": "nvd@nist.gov",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/BrianWGray/msf/blob/master/exploits/linux/ssh/eaton_known_privkey.rb"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.ctrlu.net/vuln/0006.html"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2018-16158 (GCVE-0-2018-16158)
Vulnerability from cvelistv5 – Published: 2018-08-30 05:00 – Updated: 2024-09-17 04:19
VLAI?
Summary
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T10:17:37.662Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers\u0027 installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-30T05:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-16158",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers\u0027 installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ctrlu.net/vuln/0006.html",
"refsource": "MISC",
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"name": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf",
"refsource": "MISC",
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-16158",
"datePublished": "2018-08-30T05:00:00Z",
"dateReserved": "2018-08-30T00:00:00Z",
"dateUpdated": "2024-09-17T04:19:10.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-16158 (GCVE-0-2018-16158)
Vulnerability from nvd – Published: 2018-08-30 05:00 – Updated: 2024-09-17 04:19
VLAI?
Summary
Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers' installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T10:17:37.662Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers\u0027 installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-30T05:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-16158",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Eaton Power Xpert Meter 4000, 6000, and 8000 devices before 13.4.0.10 have a single SSH private key across different customers\u0027 installations and do not properly restrict access to this key, which makes it easier for remote attackers to perform SSH logins (to uid 0) via the PubkeyAuthentication option."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.ctrlu.net/vuln/0006.html",
"refsource": "MISC",
"url": "https://www.ctrlu.net/vuln/0006.html"
},
{
"name": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf",
"refsource": "MISC",
"url": "http://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/PXM-Advisory.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-16158",
"datePublished": "2018-08-30T05:00:00Z",
"dateReserved": "2018-08-30T00:00:00Z",
"dateUpdated": "2024-09-17T04:19:10.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}