All the vulnerabilites related to hp - proliant_bl460c_gen10_server_blade
Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo xss remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29211",
  "lastModified": "2024-11-21T06:00:50.067",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.497",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de un xss dom y una inyecci\u00f3n remota de crlf en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29209",
  "lastModified": "2024-11-21T06:00:49.823",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.443",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de tipo xss remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29201",
  "lastModified": "2024-11-21T06:00:48.803",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.570",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de un xss dom y una inyecci\u00f3n remota de crlf en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29208",
  "lastModified": "2024-11-21T06:00:49.683",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.417",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo XSS remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29205",
  "lastModified": "2024-11-21T06:00:49.293",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.663",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo XSS remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29204",
  "lastModified": "2024-11-21T06:00:49.170",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.637",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo XSS remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29207",
  "lastModified": "2024-11-21T06:00:49.557",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.730",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 15:15
Modified
2024-11-21 06:00
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de un xss dom y una inyecci\u00f3n remota de crlf en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29210",
  "lastModified": "2024-11-21T06:00:49.947",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T15:15:07.470",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad de desbordamiento del b\u00fafer local en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29202",
  "lastModified": "2024-11-21T06:00:48.930",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.607",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-01-05 15:15
Modified
2024-11-21 05:36
Summary
A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information.
Impacted products
Vendor Product Version
hp integrated_lights-out_4 *
hp apollo_4200_gen9_server -
hp convergedsystem_cs700 -
hp convergedsystem_cs700x -
hp proliant_bl420c_gen8_server -
hp proliant_bl460c_gen8_server_blade -
hp proliant_bl460c_gen9_server_blade -
hp proliant_bl465c_gen8_server_blade -
hp proliant_bl660c_gen8_server_blade -
hp proliant_bl660c_gen9_server -
hp proliant_dl120_gen9_server -
hp proliant_dl160_gen8_server -
hp proliant_dl160_gen9_server -
hp proliant_dl180_gen9_server -
hp proliant_dl320e_gen8_server -
hp proliant_dl320e_gen8_v2_server -
hp proliant_dl360_gen9_server -
hp proliant_dl360e_gen8_server -
hp proliant_dl360p_gen8_server -
hp proliant_dl380_gen9_server -
hp proliant_dl380e_gen8_server -
hp proliant_dl380p_gen8_server -
hp proliant_dl385p_gen8_\(amd\) -
hp proliant_dl560_gen8_server -
hp proliant_dl560_gen9_server -
hp proliant_dl580_gen8_server -
hp proliant_dl580_gen9_server -
hp proliant_dl60_gen9_server -
hp proliant_dl80_gen9_server -
hp proliant_microserver_gen8 -
hp proliant_ml110_gen9_server -
hp proliant_ml30_gen9_server -
hp proliant_ml310e_gen8_server -
hp proliant_ml310e_gen8_v2_server -
hp proliant_ml350_gen9_server -
hp proliant_ml350e_gen8_server -
hp proliant_ml350e_gen8_v2_server -
hp proliant_ml350p_gen8_server -
hp proliant_sl210t_gen8_server -
hp proliant_sl230s_gen8_server -
hp proliant_sl250s_gen8_server -
hp proliant_sl270s_gen8_se_server -
hp proliant_sl270s_gen8_server -
hp proliant_sl4540_gen8_3_node_server -
hp proliant_ws460c_gen8_graphics_server_blade -
hp proliant_ws460c_gen9_graphics_server_blade -
hp proliant_xl170r_gen9_server -
hp proliant_xl190r_gen9_server -
hp proliant_xl220a_gen8_v2_server -
hp proliant_xl230a_gen9_server -
hp proliant_xl250a_gen9_server -
hp proliant_xl450_gen9_server -
hp proliant_xl730f_gen9_server -
hp proliant_xl740f_gen9_server -
hp proliant_xl750f_gen9_server -
hp synergy_480_gen9_compute_module -
hp integrated_lights-out_5 *
hp apollo_4200_gen10_server -
hp apollo_4510_system -
hp apollo_r2000_chassis -
hp convergedsystem_cs700 -
hp convergedsystem_cs700x -
hp proliant_bl460c_gen10_server_blade -
hp proliant_dl120_gen10_server -
hp proliant_dl160_gen10_server -
hp proliant_dl180_gen10_server -
hp proliant_dl20_gen10_server -
hp proliant_dl325_gen10_plus_server -
hp proliant_dl325_gen10_server -
hp proliant_dl360_gen10_server -
hp proliant_dl380_gen10_server -
hp proliant_dl385_gen10_plus_server -
hp proliant_dl385_gen10_server -
hp proliant_dl560_gen10_server -
hp proliant_dl580_gen10_server -
hp proliant_ml110_gen10_server -
hp proliant_ml30_gen10_server -
hp proliant_ml350_gen10_server -
hp proliant_xl170r_gen10_server -
hp proliant_xl190r_gen10_server -
hp proliant_xl230k_gen10_server -
hp proliant_xl270d_gen10_server -
hp proliant_xl450_gen10_server -
hp synergy_480_gen10_compute_module -
hp synergy_660_gen10_compute_module -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "728B6275-69A0-4235-B877-A80EAA5AE662",
              "versionEndExcluding": "2.76",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:apollo_4200_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C145C31-ED51-48CA-AC14-53A46F3DA0B9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07452929-D568-4D48-9480-6F03AD39EBC8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700x:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72DE103E-83D9-4A9C-BB91-F876448443CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl420c_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE085EBF-9338-4F4D-BA6D-DF71EB55809D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7C5EE27-AC35-490B-AF26-FDA261AA03B5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen9_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BB98203-AFC1-489F-BA7D-F66E3275774A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl465c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E16A3168-F12A-47D9-B80B-11815DDAA24E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl660c_gen8_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5E3FC67-8EBC-4EE9-B518-561602DD617F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl660c_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "66EB270B-9289-4D3D-91A8-751CF2C62BD5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2483ED79-0132-4484-808B-8DA9F2F9CE1E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35D7105B-54F9-480D-95B6-9BFACD405450",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFADFAB1-F9C7-4613-AB00-6088A54B2984",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CFBF3AAB-5A41-498D-8934-5069086AF0A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl320e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A10ED119-2AFB-4A19-8EC9-11DD00C771C3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl320e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CB4D64F-C78D-4A5A-8213-85607DD5DC3D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5562E797-E2BA-49A7-A7FD-F345F3B3EDC1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE32C218-B3DC-4915-A170-D41EA356B37F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "971D98CB-488B-475E-834F-D7F2C2D15618",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4176A85-6BA7-4A49-95A6-759655FCE437",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2B60FD7-710F-4596-AC1E-C92BE1F73185",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "089A9561-E2E3-4E6C-8E2A-3E0559306B9C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385p_gen8_\\(amd\\):-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DF8D7D0-50A7-45CE-8C57-2BF809D6D467",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B0B6A0E-982B-49F8-9CD8-675599E801DA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C250444-6DCB-492C-9C09-BCB4D8F9522E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD283162-B57B-4041-A36D-70C15C5CAD2B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E11FBED-28C9-4D77-BCE4-847115EC5A56",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl60_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03D1BA51-A089-4CB6-8B7A-44B29BE38D65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl80_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "501CE644-836D-45D7-A525-00443E496279",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_microserver_gen8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2D4A053-A170-41E8-85A6-6D7C71942130",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C226593-97C5-49C4-9906-88430D35A1A9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B479287E-D58C-432F-9B76-A6C75C4C1539",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml310e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72BD3DC2-1148-47E8-956B-379214CB0847",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml310e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34846E13-5492-4B43-BFF7-DD68DC044DF2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "22E0FE3B-24DB-416D-93FF-98CD64538A99",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350e_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16078B36-0484-43E1-91EB-507403E469FB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350e_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27B69F59-24E1-40E7-AD2A-D5C6A4E9D75C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350p_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A3DAD01F-2D0C-4055-9B68-73100C02A63E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl210t_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4976BD59-4074-4EB5-97EC-FA3E50C83245",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl230s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88C7E69C-68FC-4BB5-845E-AC78AE6213E9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl250s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07646416-DC91-44C2-AEC3-2F979C9C89B5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl270s_gen8_se_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FEF9B53-21AA-43F8-82B6-476F04D0498D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl270s_gen8_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F77695B-AE96-4A78-B818-451408BFED3A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_sl4540_gen8_3_node_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A191A1E-ED89-4E71-A113-CAB3148D9771",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ws460c_gen8_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A6ED7F-9F9C-47E1-B947-36175C7864E3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ws460c_gen9_graphics_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B60147E9-D2AA-4B5C-9975-F27921BCF547",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F3A643B-F7DA-4239-BF5D-CCB2ECD4AB46",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C3E0225-79B8-47EE-AA0F-F35D69FA2905",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl220a_gen8_v2_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B33E1DFC-4274-4488-9D64-E37D0CC4B055",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8FC258B-754A-4372-ADF1-1F2BBDA8CE54",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl250a_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D871D279-38D4-48EE-8966-C2B686390E1A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A165E3C1-14E8-421E-807A-3888B204E105",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl730f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC8A90D2-7C7F-42FA-9F35-34C2D9612C03",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl740f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B29CFA7E-6485-4FA0-816B-0CCA98BB77BE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl750f_gen9_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB222D02-E0CD-4BD2-BFED-50FC0EB8BA48",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:synergy_480_gen9_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F9CD561-6392-4F85-9D81-7A39BA8E518B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53905D4D-26A8-49B2-9AB5-C8E04B2B7712",
              "versionEndExcluding": "2.31",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:apollo_4200_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7E4EA1D-8ACB-4C6C-AB96-80BC8FD71FB3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:apollo_4510_system:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D87366D-D719-46A8-AE28-455155C8D359",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:apollo_r2000_chassis:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9311154A-E0EF-46B3-B8D0-6ED540029684",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07452929-D568-4D48-9480-6F03AD39EBC8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:convergedsystem_cs700x:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72DE103E-83D9-4A9C-BB91-F876448443CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:synergy_480_gen10_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0BD2C870-A12D-470A-94A7-DD31C4E8AB0B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:synergy_660_gen10_compute_module:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44B8A537-DF37-4D7C-8290-5254A788D087",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad de seguridad potencial en el firmware HPE Integrated Lights-Out versi\u00f3n 5 (iLO 5) e Integrated Lights-Out versi\u00f3n 4 (iLO 4).\u0026#xa0;La vulnerabilidad podr\u00eda ser explotada remotamente para divulgar el n\u00famero de serie y otra informaci\u00f3n"
    }
  ],
  "id": "CVE-2020-7202",
  "lastModified": "2024-11-21T05:36:49.233",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-01-05T15:15:14.077",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-05-25 14:15
Modified
2024-11-21 06:00
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E25CDBB-3C9D-4AAB-BA21-0346546AA369",
              "versionEndExcluding": "2.78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F05331F2-DF6B-4CD3-9BA4-B97A34746509",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD145EB4-A7F3-4A6D-A782-080507068D45",
              "versionEndExcluding": "2.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10_server_blade:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "03E00679-A2A7-4A51-9764-462BF479F423",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B553E44A-A209-49CA-A914-CC1FE51D90D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "666AAAE5-83AB-4018-891D-2FC69AE6AD65",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DD32E61-4FFE-4ECF-9582-B96D1513C706",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BDF28CD-B01A-4C31-B62A-0472AD96D255",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB5F7BC4-EAA0-47EB-A66A-B5BC60620E1F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58196CA6-BA67-4361-8056-B52B1A323E5D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5FC76C8-44FC-4BCC-95C1-0717126BBE2A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFD8AB8C-D5BA-4312-9E7A-48ECB09F3C16",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_plus_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBF5E039-BBBF-42A4-8F57-CB2B7E65D763",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306B6EC0-C471-48B6-858C-93A4A6CB976D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A16D30B-D064-4EEC-9628-7B64B63CE2CA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A367F8FE-8500-4512-831A-408BB0772586",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "358CD445-B506-4EE9-A282-76A790EA4583",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D857745-3DBE-4B0A-ACE3-0159EB3D0121",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9DB2958-DDCD-4ACA-B9C1-F7914622E36B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8A0F022-C271-4DB6-A12E-1A2357C0BFE9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "29DEE638-BD6B-4B70-ABEE-AFD8FDA99F45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7B1F484-2258-4326-AEFA-725BD8EFE6CD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl270d_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "00D87480-CB71-4BB0-A034-41B3AA9F10A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81B8CA7A-F115-4932-A932-F61180E79A72",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_2600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A13A066-1BC1-43D3-BBCC-499F1C1C864A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_325:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE4D8959-5623-4211-BE1B-80E6557D61F2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFA60F7D-DD77-4DED-B13B-C59025FCF3A2",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C077CA8B-F758-4D35-BFBA-9350586BBB91",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:simplivity_380_gen10_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DAFA4-2B9B-455D-9ABD-28D3E36859F0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
    },
    {
      "lang": "es",
      "value": "Se detect\u00f3 una vulnerabilidad  de tipo xss remota en HPE Integrated Lights-Out 4 (iLO 4);\u0026#xa0;HPE SimpliVity 380 Gen9;\u0026#xa0;HPE Integrated Lights-Out 5 (iLO 5) para servidores HPE Gen10;\u0026#xa0;HPE SimpliVity 380 Gen10;\u0026#xa0;HPE SimpliVity 2600;\u0026#xa0;HPE SimpliVity 380 Gen10 G;\u0026#xa0;HPE SimpliVity 325;\u0026#xa0;Versiones de HPE SimpliVity 380 Gen10 H: anterior a versi\u00f3n 2.78"
    }
  ],
  "id": "CVE-2021-29206",
  "lastModified": "2024-11-21T06:00:49.417",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-05-25T14:15:07.693",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2021-29205
Vulnerability from cvelistv5
Published
2021-05-25 13:37
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.271Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:37:43",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29205",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29205",
    "datePublished": "2021-05-25T13:37:43",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.271Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29202
Vulnerability from cvelistv5
Published
2021-05-25 13:24
Modified
2024-08-03 22:02
Severity ?
Summary
A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:50.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "local buffer overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:24:19",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29202",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A local buffer overflow vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "local buffer overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29202",
    "datePublished": "2021-05-25T13:24:19",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:50.533Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29201
Vulnerability from cvelistv5
Published
2021-05-25 13:24
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.300Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:24:14",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29201",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29201",
    "datePublished": "2021-05-25T13:24:14",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.300Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29206
Vulnerability from cvelistv5
Published
2021-05-25 13:53
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.072Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:53:25",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29206",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29206",
    "datePublished": "2021-05-25T13:53:25",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.072Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29210
Vulnerability from cvelistv5
Published
2021-05-25 14:11
Modified
2024-08-03 22:02
Severity ?
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.297Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote dom xss, crlf injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:11:03",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29210",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote dom xss, crlf injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29210",
    "datePublished": "2021-05-25T14:11:03",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.297Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29204
Vulnerability from cvelistv5
Published
2021-05-25 13:37
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.095Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:37:40",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29204",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29204",
    "datePublished": "2021-05-25T13:37:40",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.095Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29211
Vulnerability from cvelistv5
Published
2021-05-25 14:11
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.313Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:11:09",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29211",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29211",
    "datePublished": "2021-05-25T14:11:09",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29207
Vulnerability from cvelistv5
Published
2021-05-25 13:53
Modified
2024-08-03 22:02
Severity ?
Summary
A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.367Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote xss",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T13:53:29",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29207",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote xss vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote xss"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29207",
    "datePublished": "2021-05-25T13:53:29",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.367Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29208
Vulnerability from cvelistv5
Published
2021-05-25 14:32
Modified
2024-08-03 22:02
Severity ?
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.221Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote dom xss, crlf injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:32:42",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29208",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote dom xss, crlf injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29208",
    "datePublished": "2021-05-25T14:32:42",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.221Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-29209
Vulnerability from cvelistv5
Published
2021-05-25 14:32
Modified
2024-08-03 22:02
Severity ?
Summary
A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T22:02:51.204Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
            },
            {
              "status": "affected",
              "version": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
            },
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote dom xss, crlf injection",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-25T14:32:49",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2021-29209",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 4 (iLO 4) version 2.78"
                          },
                          {
                            "version_value": "Prior to HPE Integrated Lights-Out 5 (iLO 5) version 2.44"
                          },
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote dom xss, crlf injection vulnerability was discovered in HPE Integrated Lights-Out 4 (iLO 4); HPE SimpliVity 380 Gen9; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers; HPE SimpliVity 380 Gen10; HPE SimpliVity 2600; HPE SimpliVity 380 Gen10 G; HPE SimpliVity 325; HPE SimpliVity 380 Gen10 H version(s): Prior to version 2.78."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote dom xss, crlf injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04134en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2021-29209",
    "datePublished": "2021-05-25T14:32:49",
    "dateReserved": "2021-03-25T00:00:00",
    "dateUpdated": "2024-08-03T22:02:51.204Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-7202
Vulnerability from cvelistv5
Published
2021-01-05 14:08
Modified
2024-08-04 09:25
Severity ?
Summary
A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:48.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE ProLiant Servers, Apollo Products, Converged Systems, and Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5), or Integrated Lights-Out 4 (iLO 4)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Prior to iLO 5 v2.31"
            },
            {
              "status": "affected",
              "version": "Prior to iLO 4 v2.76"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Remote disclosure of information",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-01-05T14:08:28",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2020-7202",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE ProLiant Servers, Apollo Products, Converged Systems, and Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5), or Integrated Lights-Out 4 (iLO 4)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Prior to iLO 5 v2.31"
                          },
                          {
                            "version_value": "Prior to iLO 4 v2.76"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential security vulnerability has been identified in HPE Integrated Lights-Out 5 (iLO 5) and Integrated Lights-Out 4 (iLO 4) firmware. The vulnerability could be remotely exploited to disclose the serial number and other information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Remote disclosure of information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf04069en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2020-7202",
    "datePublished": "2021-01-05T14:08:28",
    "dateReserved": "2020-01-16T00:00:00",
    "dateUpdated": "2024-08-04T09:25:48.181Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}