Vulnerabilites related to hp - proliant_ml30_gen10
cve-2018-7117
Vulnerability from cvelistv5
Published
2019-04-09 18:28
Modified
2024-08-05 06:17
Severity ?
EPSS score ?
Summary
A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers |
Version: iLO5 prior to v1.40 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T06:17:17.554Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers", "vendor": "n/a", "versions": [ { "status": "affected", "version": "iLO5 prior to v1.40" } ] } ], "descriptions": [ { "lang": "en", "value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40." } ], "problemTypes": [ { "descriptions": [ { "description": "remote cross-site scripting", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2019-05-17T21:06:05", "orgId": "eb103674-0d28-4225-80f8-39fb86215de0", "shortName": "hpe" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "security-alert@hpe.com", "ID": "CVE-2018-7117", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers", "version": { "version_data": [ { "version_value": "iLO5 prior to v1.40" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "remote cross-site scripting" } ] } ] }, "references": { "reference_data": [ { "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us", "refsource": "MISC", "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us" }, { "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us", "refsource": "CONFIRM", "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us" } ] } } } }, "cveMetadata": { "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0", "assignerShortName": "hpe", "cveId": "CVE-2018-7117", "datePublished": "2019-04-09T18:28:18", "dateReserved": "2018-02-15T00:00:00", "dateUpdated": "2024-08-05T06:17:17.554Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2019-04-09 19:29
Modified
2024-11-21 04:11
Severity ?
Summary
A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E0694839-C434-4390-ABBD-A64A4CE3773C", "versionEndExcluding": "1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFEC03C5-6E25-47A3-9793-D411056F5D08", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "43D747DD-AF47-4B5A-B9CC-20BEC97E7788", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "7B0DEA2A-F511-4111-8B33-B029E75D56BF", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "5077B450-1E11-4338-8F76-E4257FBE9260", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "A66883DD-061A-4D0A-A73B-3EF2F7273B83", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "E013812C-A291-4F5E-BA62-B034FA8288ED", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "45369573-58FC-40E2-8124-08CDEAB6B6C0", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F5D074B-079C-4227-A2A5-654BB35E7DC3", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0766C25-5149-4A02-BC12-38D21EAE2303", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "D894E6C9-D248-4800-A138-CD0FE8F6B5B9", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FEBB303-F21A-47FF-9D79-5CBC90144782", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_microserver_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D8F597A-DBF1-4CA5-9B10-990571E2A968", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA54BDB5-28DF-46D6-8D7D-F2F4F3B21381", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_ml30_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "EFE18D61-BC0A-414F-A099-549D203C4EBE", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "7FF6A55B-05B4-4286-BF06-45D2A21EF58F", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "A6662F50-79E8-4675-ABAB-E95C7B8A2BBB", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D33F488-C5DB-40A7-BCAB-4DA1A6FC0096", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "85739B50-AA18-4097-8EAA-3A750EE38AE6", "vulnerable": false }, { "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10:-:*:*:*:*:*:*:*", "matchCriteriaId": "2C2B30A8-303D-4A47-8D9A-7088F82D2BA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40." }, { "lang": "es", "value": "Se identific\u00f3 una vulnerabilidad del tipo remote cross-site scripting en la Web User Interface de HPE iLO 5 en HPE Integrated Lights-Out 5 (iLO 5) para los servidores ProLiant Gen10 anteriores a la versi\u00f3n v1.40." } ], "id": "CVE-2018-7117", "lastModified": "2024-11-21T04:11:40.383", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-04-09T19:29:01.633", "references": [ { "source": "security-alert@hpe.com", "tags": [ "Vendor Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us" }, { "source": "security-alert@hpe.com", "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03907en_us" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us" } ], "sourceIdentifier": "security-alert@hpe.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }