All the vulnerabilites related to hp - proliant_ml350_gen9
Vulnerability from fkie_nvd
Published
2019-06-05 17:29
Modified
2024-11-21 04:22
Summary
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EEFA032-2828-4A25-AA69-490AAF9B7F1E",
              "versionEndIncluding": "1.39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFEC03C5-6E25-47A3-9793-D411056F5D08",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43D747DD-AF47-4B5A-B9CC-20BEC97E7788",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B0DEA2A-F511-4111-8B33-B029E75D56BF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5077B450-1E11-4338-8F76-E4257FBE9260",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66883DD-061A-4D0A-A73B-3EF2F7273B83",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E013812C-A291-4F5E-BA62-B034FA8288ED",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "45369573-58FC-40E2-8124-08CDEAB6B6C0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F5D074B-079C-4227-A2A5-654BB35E7DC3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0766C25-5149-4A02-BC12-38D21EAE2303",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D894E6C9-D248-4800-A138-CD0FE8F6B5B9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FEBB303-F21A-47FF-9D79-5CBC90144782",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_microserver_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D8F597A-DBF1-4CA5-9B10-990571E2A968",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA54BDB5-28DF-46D6-8D7D-F2F4F3B21381",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FF6A55B-05B4-4286-BF06-45D2A21EF58F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6662F50-79E8-4675-ABAB-E95C7B8A2BBB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D33F488-C5DB-40A7-BCAB-4DA1A6FC0096",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85739B50-AA18-4097-8EAA-3A750EE38AE6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C2B30A8-303D-4A47-8D9A-7088F82D2BA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63301635-7C6F-4854-893C-C37B74F13511",
              "versionEndIncluding": "2.61b",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E58291DF-A83D-4EED-8CEB-DCCB636E57F4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5010CA27-8B1D-43BE-A236-997E51E4B541",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67D2605F-2642-46EB-BA2C-8E33ACEC8ADA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87200D92-81D3-4FA4-BD4D-11F0DB7C1E45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81E5D6BA-A5C8-42B2-B347-1F3A70DCDC9D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED47EFC-2D0D-4864-A0CC-A6F29C236315",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml10_gen9:2:*:*:*:*:*:*:*",
              "matchCriteriaId": "97685B5D-843B-4BA4-915C-A384F323A206",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D64DCBE5-8590-4F17-A86D-88B78E9E5943",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml150_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9876313-D746-4077-A188-F2024C3689F3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen9:2:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C53512F-3577-4F64-977C-6579124DA93C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D95AA33-FD84-4766-A42A-4E44A1BC9B8B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ws460c_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76D7479C-E340-4E58-A5E5-5AA7C95EE90A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C7DE17C-AC8E-4C0B-B6B1-6D2F4958E70A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2838C1A2-23B2-4063-8C16-1558FC329EEB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230a_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40FCFF2E-22B6-4AE3-AE36-B57524656128",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl250a_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE0AA43F-DEFB-441C-84B8-85F523D600C0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl730f_gen9:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1B4FA-E67A-4EB7-A428-FF6C90F0E3B7",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl740f_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CFED4E5-48AA-4133-A2A2-4D70101593A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl750f_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6890F055-67AE-4008-A687-EEAD92D892BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
    },
    {
      "lang": "es",
      "value": "Fue encontrada una vulnerabilidad de desbordamiento de b\u00fafer remoto en HPE Integrated Lights-Out 4 (iLO 4) anterior a versi\u00f3n 2.61b para servidores Gen9 e Integrated Lights-Out 5 (iLO 5) para servidores Gen10 anteriores a la versi\u00f3n versi\u00f3n 1.39."
    }
  ],
  "id": "CVE-2019-11983",
  "lastModified": "2024-11-21T04:22:06.370",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 8.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 8.5,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 4.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-05T17:29:00.257",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-06-05 17:29
Modified
2024-11-21 04:22
Summary
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_5_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EEFA032-2828-4A25-AA69-490AAF9B7F1E",
              "versionEndIncluding": "1.39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFEC03C5-6E25-47A3-9793-D411056F5D08",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43D747DD-AF47-4B5A-B9CC-20BEC97E7788",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl160_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B0DEA2A-F511-4111-8B33-B029E75D56BF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5077B450-1E11-4338-8F76-E4257FBE9260",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl20_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66883DD-061A-4D0A-A73B-3EF2F7273B83",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl325_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E013812C-A291-4F5E-BA62-B034FA8288ED",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "45369573-58FC-40E2-8124-08CDEAB6B6C0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F5D074B-079C-4227-A2A5-654BB35E7DC3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl385_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0766C25-5149-4A02-BC12-38D21EAE2303",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl560_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D894E6C9-D248-4800-A138-CD0FE8F6B5B9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FEBB303-F21A-47FF-9D79-5CBC90144782",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_microserver_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D8F597A-DBF1-4CA5-9B10-990571E2A968",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA54BDB5-28DF-46D6-8D7D-F2F4F3B21381",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FF6A55B-05B4-4286-BF06-45D2A21EF58F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6662F50-79E8-4675-ABAB-E95C7B8A2BBB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D33F488-C5DB-40A7-BCAB-4DA1A6FC0096",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230k_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "85739B50-AA18-4097-8EAA-3A750EE38AE6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl450_gen10:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C2B30A8-303D-4A47-8D9A-7088F82D2BA3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:hp:integrated_lights-out_4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63301635-7C6F-4854-893C-C37B74F13511",
              "versionEndIncluding": "2.61b",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:hp:proliant_bl460c_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E58291DF-A83D-4EED-8CEB-DCCB636E57F4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl120_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5010CA27-8B1D-43BE-A236-997E51E4B541",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl180_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67D2605F-2642-46EB-BA2C-8E33ACEC8ADA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl360_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "87200D92-81D3-4FA4-BD4D-11F0DB7C1E45",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl380_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "81E5D6BA-A5C8-42B2-B347-1F3A70DCDC9D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_dl580_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ED47EFC-2D0D-4864-A0CC-A6F29C236315",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml10_gen9:2:*:*:*:*:*:*:*",
              "matchCriteriaId": "97685B5D-843B-4BA4-915C-A384F323A206",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml110_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D64DCBE5-8590-4F17-A86D-88B78E9E5943",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml150_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B9876313-D746-4077-A188-F2024C3689F3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml30_gen9:2:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C53512F-3577-4F64-977C-6579124DA93C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ml350_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D95AA33-FD84-4766-A42A-4E44A1BC9B8B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_ws460c_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76D7479C-E340-4E58-A5E5-5AA7C95EE90A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl170r_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C7DE17C-AC8E-4C0B-B6B1-6D2F4958E70A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl190r_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2838C1A2-23B2-4063-8C16-1558FC329EEB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl230a_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40FCFF2E-22B6-4AE3-AE36-B57524656128",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl250a_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE0AA43F-DEFB-441C-84B8-85F523D600C0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl730f_gen9:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C1B4FA-E67A-4EB7-A428-FF6C90F0E3B7",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl740f_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CFED4E5-48AA-4133-A2A2-4D70101593A4",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:hp:proliant_xl750f_gen9:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6890F055-67AE-4008-A687-EEAD92D892BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
    },
    {
      "lang": "es",
      "value": "Fue encontrada una vulnerabilidad de tipo cross site scripting remota en HPE Integrated Lights-Out 4 (iLO 4) anterior a la versi\u00f3n 2.61b para servidores Gen9 e Integrated Lights-Out 5 (iLO 5) para servidores Gen10 anteriores a la versi\u00f3n 1.39."
    }
  ],
  "id": "CVE-2019-11982",
  "lastModified": "2024-11-21T04:22:06.240",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "HIGH",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.6,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:H/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 4.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 6.0,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-06-05T17:29:00.227",
  "references": [
    {
      "source": "security-alert@hpe.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
    }
  ],
  "sourceIdentifier": "security-alert@hpe.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2019-11982
Vulnerability from cvelistv5
Published
2019-06-05 16:35
Modified
2024-08-04 23:10
Severity ?
Summary
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.994Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE iLO4 and HPE iLO5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
            }
          ]
        }
      ],
      "datePublic": "2019-05-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "cross site scripting",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-05T16:35:10",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2019-11982",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE iLO4 and HPE iLO5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "cross site scripting"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2019-11982",
    "datePublished": "2019-06-05T16:35:10",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-08-04T23:10:29.994Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-11983
Vulnerability from cvelistv5
Published
2019-06-05 16:36
Modified
2024-08-04 23:10
Severity ?
Summary
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.947Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE iLO4 and HPE iLO5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
            }
          ]
        }
      ],
      "datePublic": "2019-05-17T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote buffer overflow",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-06-05T16:36:07",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2019-11983",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE iLO4 and HPE iLO5",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "iLO4 prior to v2.61b and iLO5 prior to v1.39"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote buffer overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03917en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2019-11983",
    "datePublished": "2019-06-05T16:36:07",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-08-04T23:10:29.947Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}