Search criteria
3 vulnerabilities found for px360bt_firmware by positron
FKIE_CVE-2025-56448
Vulnerability from fkie_nvd - Published: 2025-09-15 20:15 - Updated: 2025-10-14 19:33
Severity ?
Summary
The Positron PX360BT SW REV 8 car alarm system is vulnerable to a replay attack due to a failure in implementing rolling code security. The alarm system does not properly rotate or invalidate used codes, allowing repeated reuse of captured transmissions. This exposes users to significant security risks, including vehicle theft and loss of trust in the alarm's anti-cloning claims.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| positron | px360bt_firmware | rev8 | |
| positron | px360bt | 8200101542 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:positron:px360bt_firmware:rev8:*:*:*:*:*:*:*",
"matchCriteriaId": "55DE6A92-75AF-4D93-A919-1424EFC9885E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:positron:px360bt:8200101542:*:*:*:*:*:*:*",
"matchCriteriaId": "64ED6D0E-C24F-44DC-BCA6-A6E9CC097A7F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Positron PX360BT SW REV 8 car alarm system is vulnerable to a replay attack due to a failure in implementing rolling code security. The alarm system does not properly rotate or invalidate used codes, allowing repeated reuse of captured transmissions. This exposes users to significant security risks, including vehicle theft and loss of trust in the alarm\u0027s anti-cloning claims."
}
],
"id": "CVE-2025-56448",
"lastModified": "2025-10-14T19:33:01.220",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-09-15T20:15:38.127",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://medium.com/@wagneralves_87750/cve-2025-56448-replay-attack-vulnerability-in-positron-px360bt-car-alarm-system-c9f1ccea6ebe"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://positron.com.br/blog/positron-lanca-alarme-px360bt-starter/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-294"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
CVE-2025-56448 (GCVE-0-2025-56448)
Vulnerability from cvelistv5 – Published: 2025-09-15 00:00 – Updated: 2025-09-15 20:38
VLAI?
Summary
The Positron PX360BT SW REV 8 car alarm system is vulnerable to a replay attack due to a failure in implementing rolling code security. The alarm system does not properly rotate or invalidate used codes, allowing repeated reuse of captured transmissions. This exposes users to significant security risks, including vehicle theft and loss of trust in the alarm's anti-cloning claims.
Severity ?
6.8 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56448",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T20:37:06.637330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T20:38:00.539Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Positron PX360BT SW REV 8 car alarm system is vulnerable to a replay attack due to a failure in implementing rolling code security. The alarm system does not properly rotate or invalidate used codes, allowing repeated reuse of captured transmissions. This exposes users to significant security risks, including vehicle theft and loss of trust in the alarm\u0027s anti-cloning claims."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T20:06:00.822Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://positron.com.br/blog/positron-lanca-alarme-px360bt-starter/"
},
{
"url": "https://medium.com/@wagneralves_87750/cve-2025-56448-replay-attack-vulnerability-in-positron-px360bt-car-alarm-system-c9f1ccea6ebe"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56448",
"datePublished": "2025-09-15T00:00:00.000Z",
"dateReserved": "2025-08-17T00:00:00.000Z",
"dateUpdated": "2025-09-15T20:38:00.539Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-56448 (GCVE-0-2025-56448)
Vulnerability from nvd – Published: 2025-09-15 00:00 – Updated: 2025-09-15 20:38
VLAI?
Summary
The Positron PX360BT SW REV 8 car alarm system is vulnerable to a replay attack due to a failure in implementing rolling code security. The alarm system does not properly rotate or invalidate used codes, allowing repeated reuse of captured transmissions. This exposes users to significant security risks, including vehicle theft and loss of trust in the alarm's anti-cloning claims.
Severity ?
6.8 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-56448",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-15T20:37:06.637330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-294",
"description": "CWE-294 Authentication Bypass by Capture-replay",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T20:38:00.539Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Positron PX360BT SW REV 8 car alarm system is vulnerable to a replay attack due to a failure in implementing rolling code security. The alarm system does not properly rotate or invalidate used codes, allowing repeated reuse of captured transmissions. This exposes users to significant security risks, including vehicle theft and loss of trust in the alarm\u0027s anti-cloning claims."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-15T20:06:00.822Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://positron.com.br/blog/positron-lanca-alarme-px360bt-starter/"
},
{
"url": "https://medium.com/@wagneralves_87750/cve-2025-56448-replay-attack-vulnerability-in-positron-px360bt-car-alarm-system-c9f1ccea6ebe"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-56448",
"datePublished": "2025-09-15T00:00:00.000Z",
"dateReserved": "2025-08-17T00:00:00.000Z",
"dateUpdated": "2025-09-15T20:38:00.539Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}