All the vulnerabilites related to netgear - rbr850
cve-2021-45616
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.869Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064527/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0576" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:35:57", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064527/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0576" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45616", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064527/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0576", "refsource": "MISC", "url": "https://kb.netgear.com/000064527/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0576" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45616", "datePublished": "2021-12-26T00:35:57", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.869Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45576
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.917Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:44:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45576", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084", "refsource": "MISC", "url": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45576", "datePublished": "2021-12-26T00:44:30", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.917Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26906
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.867Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062348/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0048" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:32:57", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062348/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0048" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26906", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062348/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0048", "refsource": "MISC", "url": "https://kb.netgear.com/000062348/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0048" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26906", "datePublished": "2020-10-09T06:32:57", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.867Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45614
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:02.115Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0520" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:36:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0520" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45614", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0520", "refsource": "MISC", "url": "https://kb.netgear.com/000064141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0520" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45614", "datePublished": "2021-12-26T00:36:20", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:02.115Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45634
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.761Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:32:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45634", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515", "refsource": "MISC", "url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45634", "datePublished": "2021-12-26T00:32:18", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.761Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45592
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.301Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064114/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0100" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:41:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064114/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0100" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45592", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064114/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0100", "refsource": "MISC", "url": "https://kb.netgear.com/000064114/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0100" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45592", "datePublished": "2021-12-26T00:41:39", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.301Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45569
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.335Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064091/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0077" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:46:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064091/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0077" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45569", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064091/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0077", "refsource": "MISC", "url": "https://kb.netgear.com/000064091/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0077" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45569", "datePublished": "2021-12-26T00:46:56", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.335Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29067
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.518Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29067", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492", "refsource": "MISC", "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29067", "datePublished": "2021-03-23T07:00:28", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.518Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45536
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.467Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:54:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45536", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056", "refsource": "MISC", "url": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45536", "datePublished": "2021-12-26T00:54:41", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.467Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29074
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.649Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:37", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29074", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467", "refsource": "MISC", "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29074", "datePublished": "2021-03-23T06:59:37", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.649Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38516
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:44:23.403Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063780/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2020-0273" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects D6220 before 1.0.0.48, D6400 before 1.0.0.82, D7000v2 before 1.0.0.52, D7800 before 1.0.1.44, D8500 before 1.0.3.43, DC112A before 1.0.0.40, DGN2200v4 before 1.0.0.108, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, R6020 before 1.0.0.34, R6080 before 1.0.0.34, R6120 before 1.0.0.44, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6250 before 1.0.4.34, R6260 before 1.1.0.40, R6850 before 1.1.0.40, R6350 before 1.1.0.40, R6400v2 before 1.0.2.62, R6700v3 before 1.0.2.62, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7000 before 1.0.9.34, R6900P before 1.3.1.44, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7200 before 1.2.0.48, R7350 before 1.2.0.48, R7400 before 1.2.0.48, R7450 before 1.2.0.36, AC2100 before 1.2.0.36, AC2400 before 1.2.0.36, AC2600 before 1.2.0.36, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, R7900 before 1.0.3.8, R7960P before 1.4.1.44, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RAX120 before 1.0.0.74, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, WNR3500Lv2 before 1.2.0.56, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-11T00:03:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063780/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2020-0273" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-38516", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects D6220 before 1.0.0.48, D6400 before 1.0.0.82, D7000v2 before 1.0.0.52, D7800 before 1.0.1.44, D8500 before 1.0.3.43, DC112A before 1.0.0.40, DGN2200v4 before 1.0.0.108, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, R6020 before 1.0.0.34, R6080 before 1.0.0.34, R6120 before 1.0.0.44, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6250 before 1.0.4.34, R6260 before 1.1.0.40, R6850 before 1.1.0.40, R6350 before 1.1.0.40, R6400v2 before 1.0.2.62, R6700v3 before 1.0.2.62, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7000 before 1.0.9.34, R6900P before 1.3.1.44, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7200 before 1.2.0.48, R7350 before 1.2.0.48, R7400 before 1.2.0.48, R7450 before 1.2.0.36, AC2100 before 1.2.0.36, AC2400 before 1.2.0.36, AC2600 before 1.2.0.36, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, R7900 before 1.0.3.8, R7960P before 1.4.1.44, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RAX120 before 1.0.0.74, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, WNR3500Lv2 before 1.2.0.56, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063780/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2020-0273", "refsource": "MISC", "url": "https://kb.netgear.com/000063780/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2020-0273" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-38516", "datePublished": "2021-08-11T00:03:18", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-08-04T01:44:23.403Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45670
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.773Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:25:17", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45670", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255", "refsource": "MISC", "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45670", "datePublished": "2021-12-26T00:25:17", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.773Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45509
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.208Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064148/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0564" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:01:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064148/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0564" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45509", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064148/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0564", "refsource": "MISC", "url": "https://kb.netgear.com/000064148/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0564" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45509", "datePublished": "2021-12-26T01:01:52", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.208Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14442
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.605Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:40:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14442", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14442", "datePublished": "2020-06-18T16:40:19", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.605Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45588
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.885Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064110/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0096" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:42:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064110/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0096" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45588", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064110/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0096", "refsource": "MISC", "url": "https://kb.netgear.com/000064110/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0096" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45588", "datePublished": "2021-12-26T00:42:19", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.885Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14437
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.680Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:37:40", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14437", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14437", "datePublished": "2020-06-18T16:37:40", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.680Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35794
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.224Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:39:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35794", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034", "refsource": "MISC", "url": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35794", "datePublished": "2020-12-29T23:39:06", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.224Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26899
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:23.044Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:34:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26899", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030", "refsource": "MISC", "url": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26899", "datePublished": "2020-10-09T06:34:09", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:23.044Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45667
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.865Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:25:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45667", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256", "refsource": "MISC", "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45667", "datePublished": "2021-12-26T00:25:53", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.865Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14436
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.600Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:35:43", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14436", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14436", "datePublished": "2020-06-18T16:35:43", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.600Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45572
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.124Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064094/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0080" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:46:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064094/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0080" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45572", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064094/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0080", "refsource": "MISC", "url": "https://kb.netgear.com/000064094/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0080" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45572", "datePublished": "2021-12-26T00:46:18", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.124Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45633
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.817Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:32:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45633", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514", "refsource": "MISC", "url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45633", "datePublished": "2021-12-26T00:32:28", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.817Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14430
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.455Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:26:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14430", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14430", "datePublished": "2020-06-18T16:26:18", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.455Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45568
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.169Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064090/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0076" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:47:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064090/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0076" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45568", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064090/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0076", "refsource": "MISC", "url": "https://kb.netgear.com/000064090/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0076" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45568", "datePublished": "2021-12-26T00:47:05", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.169Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45629
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.819Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:33:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45629", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488", "refsource": "MISC", "url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45629", "datePublished": "2021-12-26T00:33:18", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.819Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45591
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.454Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064113/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0099" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:41:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064113/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0099" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45591", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064113/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0099", "refsource": "MISC", "url": "https://kb.netgear.com/000064113/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0099" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45591", "datePublished": "2021-12-26T00:41:49", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.454Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26900
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.937Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062354/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0032" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:33:58", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062354/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0032" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26900", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062354/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0032", "refsource": "MISC", "url": "https://kb.netgear.com/000062354/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0032" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26900", "datePublished": "2020-10-09T06:33:58", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.937Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45570
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.365Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064092/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0078" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:46:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064092/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0078" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45570", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064092/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0078", "refsource": "MISC", "url": "https://kb.netgear.com/000064092/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0078" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45570", "datePublished": "2021-12-26T00:46:46", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.365Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45565
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.109Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064086/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0069" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:48:19", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064086/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0069" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45565", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064086/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0069", "refsource": "MISC", "url": "https://kb.netgear.com/000064086/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0069" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45565", "datePublished": "2021-12-26T00:48:19", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.109Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45635
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.751Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:32:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45635", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491", "refsource": "MISC", "url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45635", "datePublished": "2021-12-26T00:32:07", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.751Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45630
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.872Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:32:59", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45630", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498", "refsource": "MISC", "url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45630", "datePublished": "2021-12-26T00:32:59", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.872Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45561
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.453Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064165/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0059" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:50:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064165/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0059" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45561", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064165/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0059", "refsource": "MISC", "url": "https://kb.netgear.com/000064165/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0059" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45561", "datePublished": "2021-12-26T00:50:01", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.453Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45615
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.370Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:36:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45615", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521", "refsource": "MISC", "url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45615", "datePublished": "2021-12-26T00:36:07", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.370Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45574
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.113Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064096/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0082" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:45:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064096/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0082" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45574", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064096/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0082", "refsource": "MISC", "url": "https://kb.netgear.com/000064096/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0082" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45574", "datePublished": "2021-12-26T00:45:01", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.113Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26901
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.806Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062353/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0036" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:33:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062353/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0036" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26901", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062353/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0036", "refsource": "MISC", "url": "https://kb.netgear.com/000062353/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0036" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26901", "datePublished": "2020-10-09T06:33:49", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.806Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45566
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.533Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064087/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0070" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:48:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064087/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0070" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45566", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064087/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0070", "refsource": "MISC", "url": "https://kb.netgear.com/000064087/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0070" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45566", "datePublished": "2021-12-26T00:48:09", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.533Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14429
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.531Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:25:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14429", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14429", "datePublished": "2020-06-18T16:25:30", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.531Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45564
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.372Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064085/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0067" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:48:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064085/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0067" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45564", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064085/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0067", "refsource": "MISC", "url": "https://kb.netgear.com/000064085/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0067" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45564", "datePublished": "2021-12-26T00:48:30", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.372Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26907
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.905Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:32:03", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26907", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264", "refsource": "MISC", "url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26907", "datePublished": "2020-10-09T06:32:03", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.905Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45586
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.090Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064108/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0094" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:42:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064108/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0094" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45586", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064108/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0094", "refsource": "MISC", "url": "https://kb.netgear.com/000064108/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0094" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45586", "datePublished": "2021-12-26T00:42:41", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.090Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14433
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.580Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:33:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14433", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14433", "datePublished": "2020-06-18T16:33:53", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.580Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29076
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.657Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:23", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29076", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485", "refsource": "MISC", "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29076", "datePublished": "2021-03-23T06:59:23", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.657Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45575
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.302Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064097/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0083" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:44:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064097/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0083" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45575", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064097/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0083", "refsource": "MISC", "url": "https://kb.netgear.com/000064097/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0083" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45575", "datePublished": "2021-12-26T00:44:46", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.302Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29080
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.513Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:58:53", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29080", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150", "refsource": "MISC", "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29080", "datePublished": "2021-03-23T06:58:53", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.513Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26897
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.779Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062357/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0045" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:34:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062357/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0045" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26897", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062357/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0045", "refsource": "MISC", "url": "https://kb.netgear.com/000062357/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0045" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26897", "datePublished": "2020-10-09T06:34:28", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.779Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45542
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.481Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064143/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0540" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:53:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064143/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0540" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45542", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064143/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0540", "refsource": "MISC", "url": "https://kb.netgear.com/000064143/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0540" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45542", "datePublished": "2021-12-26T00:53:42", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.481Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45628
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.676Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:33:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45628", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472", "refsource": "MISC", "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45628", "datePublished": "2021-12-26T00:33:39", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.676Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45507
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.394Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:02:10", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45507", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487", "refsource": "MISC", "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45507", "datePublished": "2021-12-26T01:02:10", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.394Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45612
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.915Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:36:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45612", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524", "refsource": "MISC", "url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45612", "datePublished": "2021-12-26T00:36:39", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.915Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35795
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.223Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:29:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35795", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154", "refsource": "MISC", "url": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35795", "datePublished": "2020-12-29T23:29:56", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.223Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26910
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.926Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062343/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0031" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:31:34", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062343/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0031" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26910", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062343/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0031", "refsource": "MISC", "url": "https://kb.netgear.com/000062343/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0031" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26910", "datePublished": "2020-10-09T06:31:34", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.926Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14434
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.525Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:34:38", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14434", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14434", "datePublished": "2020-06-18T16:34:38", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.525Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45545
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.524Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064522/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0557" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:53:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064522/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0557" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45545", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064522/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0557", "refsource": "MISC", "url": "https://kb.netgear.com/000064522/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0557" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45545", "datePublished": "2021-12-26T00:53:06", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.524Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45547
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.514Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064525/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0567" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:52:46", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064525/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0567" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45547", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064525/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0567", "refsource": "MISC", "url": "https://kb.netgear.com/000064525/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0567" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45547", "datePublished": "2021-12-26T00:52:46", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.514Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45541
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.491Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:53:54", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45541", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246", "refsource": "MISC", "url": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45541", "datePublished": "2021-12-26T00:53:54", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.491Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29070
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.605Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29070", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530", "refsource": "MISC", "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29070", "datePublished": "2021-03-23T07:00:05", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.605Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45571
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.455Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064093/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0079" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:46:35", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064093/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0079" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45571", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064093/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0079", "refsource": "MISC", "url": "https://kb.netgear.com/000064093/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0079" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45571", "datePublished": "2021-12-26T00:46:35", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.455Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45671
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.877Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:25:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45671", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261", "refsource": "MISC", "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45671", "datePublished": "2021-12-26T00:25:07", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.877Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29078
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.616Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29078", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511", "refsource": "MISC", "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29078", "datePublished": "2021-03-23T06:59:09", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.616Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45560
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.249Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064081/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0057" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:50:14", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064081/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0057" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45560", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064081/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0057", "refsource": "MISC", "url": "https://kb.netgear.com/000064081/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0057" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45560", "datePublished": "2021-12-26T00:50:14", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.249Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45543
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.501Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064517/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0541" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R8000 before 1.0.4.74, RAX200 before 1.0.4.120, R8000P before 1.4.2.84, R7900P before 1.4.2.84, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBK852 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:53:32", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064517/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0541" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45543", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R8000 before 1.0.4.74, RAX200 before 1.0.4.120, R8000P before 1.4.2.84, R7900P before 1.4.2.84, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBK852 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064517/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0541", "refsource": "MISC", "url": "https://kb.netgear.com/000064517/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0541" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45543", "datePublished": "2021-12-26T00:53:32", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.501Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29082
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.631Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:58:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29082", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037", "refsource": "MISC", "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29082", "datePublished": "2021-03-23T06:58:28", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.631Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29075
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.479Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29075", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466", "refsource": "MISC", "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29075", "datePublished": "2021-03-23T06:59:31", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.479Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45613
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.168Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:36:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45613", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508", "refsource": "MISC", "url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45613", "datePublished": "2021-12-26T00:36:29", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.168Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29068
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.644Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:L/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:04:52", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29068", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:L/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155", "refsource": "MISC", "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29068", "datePublished": "2021-03-23T06:57:00", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.644Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45546
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.417Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:52:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45546", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566", "refsource": "MISC", "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45546", "datePublished": "2021-12-26T00:52:56", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.417Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14426
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.252Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:20:03", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14426", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14426", "datePublished": "2020-06-18T16:20:03", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.252Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45516
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.393Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064060/Security-Advisory-for-Denial-of-Service-on-Some-Routers-and-WiFi-Systems-PSV-2019-0115" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6400 before 1.0.1.70, R7000 before 1.0.11.126, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R8000 before 1.0.4.74, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:L/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:00:30", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064060/Security-Advisory-for-Denial-of-Service-on-Some-Routers-and-WiFi-Systems-PSV-2019-0115" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45516", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6400 before 1.0.1.70, R7000 before 1.0.11.126, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R8000 before 1.0.4.74, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:L/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064060/Security-Advisory-for-Denial-of-Service-on-Some-Routers-and-WiFi-Systems-PSV-2019-0115", "refsource": "MISC", "url": "https://kb.netgear.com/000064060/Security-Advisory-for-Denial-of-Service-on-Some-Routers-and-WiFi-Systems-PSV-2019-0115" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45516", "datePublished": "2021-12-26T01:00:30", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.393Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14427
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.311Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:21:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14427", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14427", "datePublished": "2020-06-18T16:21:05", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.311Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45599
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.290Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064145/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0546" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:39:23", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064145/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0546" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45599", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064145/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0546", "refsource": "MISC", "url": "https://kb.netgear.com/000064145/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0546" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45599", "datePublished": "2021-12-26T00:39:23", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.290Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29077
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.666Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:16", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29077", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486", "refsource": "MISC", "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29077", "datePublished": "2021-03-23T06:59:16", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.666Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35802
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.188Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:37:56", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35802", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:N/C:H/I:N/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331", "refsource": "MISC", "url": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35802", "datePublished": "2020-12-29T23:37:56", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.188Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45582
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.962Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064104/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0090" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:43:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064104/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0090" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45582", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064104/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0090", "refsource": "MISC", "url": "https://kb.netgear.com/000064104/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0090" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45582", "datePublished": "2021-12-26T00:43:31", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.962Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45559
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.434Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064079/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0055" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:50:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064079/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0055" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45559", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064079/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0055", "refsource": "MISC", "url": "https://kb.netgear.com/000064079/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0055" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45559", "datePublished": "2021-12-26T00:50:27", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.434Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45601
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.817Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064147/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0563" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:38:59", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064147/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0563" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45601", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064147/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0563", "refsource": "MISC", "url": "https://kb.netgear.com/000064147/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0563" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45601", "datePublished": "2021-12-26T00:38:59", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.817Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45584
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.754Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0092" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:43:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0092" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45584", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0092", "refsource": "MISC", "url": "https://kb.netgear.com/000064106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0092" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45584", "datePublished": "2021-12-26T00:43:01", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.754Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29081
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.508Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:58:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29081", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465", "refsource": "MISC", "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29081", "datePublished": "2021-03-23T06:58:41", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.508Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14431
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.563Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:26:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14431", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14431", "datePublished": "2020-06-18T16:26:41", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.563Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29072
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.619Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29072", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493", "refsource": "MISC", "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29072", "datePublished": "2021-03-23T06:59:51", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.619Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45503
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.197Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064127/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0474" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:02:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064127/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0474" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45503", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064127/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0474", "refsource": "MISC", "url": "https://kb.netgear.com/000064127/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0474" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45503", "datePublished": "2021-12-26T01:02:51", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.197Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45579
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.111Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:43:58", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45579", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087", "refsource": "MISC", "url": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45579", "datePublished": "2021-12-26T00:43:58", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.111Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45600
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.693Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:39:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45600", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555", "refsource": "MISC", "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45600", "datePublished": "2021-12-26T00:39:12", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.693Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14439
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.372Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:38:47", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14439", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14439", "datePublished": "2020-06-18T16:38:47", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.372Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26904
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:23.152Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062350/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0046" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:33:21", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062350/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0046" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26904", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062350/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0046", "refsource": "MISC", "url": "https://kb.netgear.com/000062350/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0046" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26904", "datePublished": "2020-10-09T06:33:21", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:23.152Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45537
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.427Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:54:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45537", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061", "refsource": "MISC", "url": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45537", "datePublished": "2021-12-26T00:54:31", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.427Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26928
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:23.151Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062324/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0027" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:27:03", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062324/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0027" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26928", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062324/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0027", "refsource": "MISC", "url": "https://kb.netgear.com/000062324/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0027" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26928", "datePublished": "2020-10-09T06:27:03", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:23.151Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45544
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.475Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064518/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0556" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:53:18", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064518/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0556" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45544", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064518/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0556", "refsource": "MISC", "url": "https://kb.netgear.com/000064518/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0556" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45544", "datePublished": "2021-12-26T00:53:18", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.475Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45627
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.675Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064124/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0471" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:33:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064124/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0471" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45627", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064124/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0471", "refsource": "MISC", "url": "https://kb.netgear.com/000064124/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0471" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45627", "datePublished": "2021-12-26T00:33:49", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.675Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45580
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.587Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064102/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0088" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:43:50", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064102/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0088" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45580", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064102/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0088", "refsource": "MISC", "url": "https://kb.netgear.com/000064102/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0088" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45580", "datePublished": "2021-12-26T00:43:50", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.587Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29071
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.613Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:58", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29071", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476", "refsource": "MISC", "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29071", "datePublished": "2021-03-23T06:59:58", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.613Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45596
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.336Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064140/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0516" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:39:57", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064140/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0516" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45596", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064140/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0516", "refsource": "MISC", "url": "https://kb.netgear.com/000064140/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0516" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45596", "datePublished": "2021-12-26T00:39:57", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.336Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14441
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.611Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:39:36", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14441", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14441", "datePublished": "2020-06-18T16:39:36", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.611Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29065
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.614Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "NETGEAR RBR850 devices before 3.2.10.11 are affected by authentication bypass." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:43", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29065", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "NETGEAR RBR850 devices before 3.2.10.11 are affected by authentication bypass." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029", "refsource": "MISC", "url": "https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29065", "datePublished": "2021-03-23T07:00:43", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.614Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45562
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.400Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:49:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45562", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060", "refsource": "MISC", "url": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45562", "datePublished": "2021-12-26T00:49:51", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.400Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14440
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.308Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:39:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14440", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14440", "datePublished": "2020-06-18T16:39:13", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.308Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45578
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.282Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:44:08", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45578", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086", "refsource": "MISC", "url": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45578", "datePublished": "2021-12-26T00:44:08", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.282Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38513
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:44:23.496Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063777/Security-Advisory-for-Authentication-Bypass-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0008" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, MK62 before 1.0.6.110, MR60 before 1.0.6.110, MS60 before 1.0.6.110, RBK752 before 3.2.10.10, RBR750 before 3.2.10.10, and RBS750 before 3.2.10.10." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-11T00:03:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063777/Security-Advisory-for-Authentication-Bypass-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0008" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-38513", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, MK62 before 1.0.6.110, MR60 before 1.0.6.110, MS60 before 1.0.6.110, RBK752 before 3.2.10.10, RBR750 before 3.2.10.10, and RBS750 before 3.2.10.10." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063777/Security-Advisory-for-Authentication-Bypass-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0008", "refsource": "MISC", "url": "https://kb.netgear.com/000063777/Security-Advisory-for-Authentication-Bypass-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0008" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-38513", "datePublished": "2021-08-11T00:03:49", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-08-04T01:44:23.496Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45590
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.795Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0098" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:41:59", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0098" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45590", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0098", "refsource": "MISC", "url": "https://kb.netgear.com/000064112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0098" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45590", "datePublished": "2021-12-26T00:41:59", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.795Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45515
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:00:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45515", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286", "refsource": "MISC", "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45515", "datePublished": "2021-12-26T01:00:39", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45535
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.498Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064457/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0052" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.3.106, RAX80 before 1.0.3.106, RAX75 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:54:50", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064457/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0052" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45535", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.3.106, RAX80 before 1.0.3.106, RAX75 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064457/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0052", "refsource": "MISC", "url": "https://kb.netgear.com/000064457/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0052" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45535", "datePublished": "2021-12-26T00:54:50", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.498Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35800
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.177Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062733/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0112" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D6000 before 1.0.0.80, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D7800 before 1.0.3.48, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, DM200 before 1.0.0.66, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX2700 before 1.0.1.58, EX3110 before 1.0.1.68, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100v2 before 1.0.1.94, EX6110 before 1.0.1.68, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150v1 before 1.0.0.46, EX6150v2 before 1.0.1.94, EX6200v1 before 1.0.3.94, EX6250 before 1.0.0.128, EX6400 before 1.0.2.152, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7300 before 1.0.2.152, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, EX7500 before 1.0.0.68, EX7700 before 1.0.0.210, EX8000 before 1.0.1.224, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.42, R6260 before 1.1.0.76, R6300v2 before 1.0.4.42, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400v1 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v1 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900 before 1.0.2.16, R6900P before 1.3.2.124, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7500v2 before 1.0.3.48, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.5.24, RAX35 before 1.0.3.80, RAX40 before 1.0.3.80, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.38, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.5.1.6, RBS40V-200 before 1.0.0.46, RBS50Y before 2.6.1.40, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3000RPv3 before 1.0.2.86, WN3500RPv1 before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:L/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:29:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062733/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0112" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35800", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D6000 before 1.0.0.80, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D7800 before 1.0.3.48, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, DM200 before 1.0.0.66, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX2700 before 1.0.1.58, EX3110 before 1.0.1.68, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100v2 before 1.0.1.94, EX6110 before 1.0.1.68, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150v1 before 1.0.0.46, EX6150v2 before 1.0.1.94, EX6200v1 before 1.0.3.94, EX6250 before 1.0.0.128, EX6400 before 1.0.2.152, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7300 before 1.0.2.152, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, EX7500 before 1.0.0.68, EX7700 before 1.0.0.210, EX8000 before 1.0.1.224, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.42, R6260 before 1.1.0.76, R6300v2 before 1.0.4.42, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400v1 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v1 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900 before 1.0.2.16, R6900P before 1.3.2.124, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7500v2 before 1.0.3.48, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.5.24, RAX35 before 1.0.3.80, RAX40 before 1.0.3.80, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.38, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.5.1.6, RBS40V-200 before 1.0.0.46, RBS50Y before 2.6.1.40, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3000RPv3 before 1.0.2.86, WN3500RPv1 before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:L/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062733/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0112", "refsource": "MISC", "url": "https://kb.netgear.com/000062733/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0112" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35800", "datePublished": "2020-12-29T23:29:39", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.177Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26905
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.926Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062349/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0047" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:33:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062349/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0047" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26905", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062349/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0047", "refsource": "MISC", "url": "https://kb.netgear.com/000062349/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0047" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26905", "datePublished": "2020-10-09T06:33:13", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.926Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45598
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.334Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064144/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0544" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:39:33", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064144/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0544" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45598", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064144/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0544", "refsource": "MISC", "url": "https://kb.netgear.com/000064144/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0544" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45598", "datePublished": "2021-12-26T00:39:33", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.334Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45620
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.265Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064510/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0509" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:35:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064510/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0509" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45620", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064510/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0509", "refsource": "MISC", "url": "https://kb.netgear.com/000064510/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0509" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45620", "datePublished": "2021-12-26T00:35:01", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.265Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45632
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.517Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:32:38", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45632", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505", "refsource": "MISC", "url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45632", "datePublished": "2021-12-26T00:32:38", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.517Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38527
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:44:23.463Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063778/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Extenders-Routers-and-WiFi-Systems-PSV-2020-0025" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-11T00:01:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063778/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Extenders-Routers-and-WiFi-Systems-PSV-2020-0025" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-38527", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063778/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Extenders-Routers-and-WiFi-Systems-PSV-2020-0025", "refsource": "MISC", "url": "https://kb.netgear.com/000063778/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Extenders-Routers-and-WiFi-Systems-PSV-2020-0025" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-38527", "datePublished": "2021-08-11T00:01:06", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-08-04T01:44:23.463Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26902
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.747Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062352/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0041" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:33:42", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062352/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0041" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26902", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062352/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0041", "refsource": "MISC", "url": "https://kb.netgear.com/000062352/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0041" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26902", "datePublished": "2020-10-09T06:33:42", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.747Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45597
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.266Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064142/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0539" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:39:43", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064142/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0539" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45597", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064142/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0539", "refsource": "MISC", "url": "https://kb.netgear.com/000064142/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0539" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45597", "datePublished": "2021-12-26T00:39:43", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.266Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14428
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.682Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:21:45", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14428", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14428", "datePublished": "2020-06-18T16:21:45", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.682Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45527
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.497Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:58:02", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45527", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437", "refsource": "MISC", "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45527", "datePublished": "2021-12-26T00:58:02", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45504
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.195Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064128/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0475" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:02:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064128/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0475" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45504", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064128/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0475", "refsource": "MISC", "url": "https://kb.netgear.com/000064128/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0475" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45504", "datePublished": "2021-12-26T01:02:41", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.195Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45622
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.216Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064509/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extender-WiFi-Systems-PSV-2020-0506" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:34:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064509/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extender-WiFi-Systems-PSV-2020-0506" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45622", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064509/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extender-WiFi-Systems-PSV-2020-0506", "refsource": "MISC", "url": "https://kb.netgear.com/000064509/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extender-WiFi-Systems-PSV-2020-0506" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45622", "datePublished": "2021-12-26T00:34:41", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.216Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45577
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.375Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064099/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0085" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:44:17", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064099/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0085" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45577", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064099/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0085", "refsource": "MISC", "url": "https://kb.netgear.com/000064099/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0085" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45577", "datePublished": "2021-12-26T00:44:17", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.375Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29066
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.497Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T07:00:35", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29066", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484", "refsource": "MISC", "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29066", "datePublished": "2021-03-23T07:00:35", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.497Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45502
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.180Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:03:05", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45502", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473", "refsource": "MISC", "url": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45502", "datePublished": "2021-12-26T01:03:05", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.180Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45587
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.070Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:42:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45587", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095", "refsource": "MISC", "url": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45587", "datePublished": "2021-12-26T00:42:28", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.070Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45585
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.947Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064107/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0093" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:42:51", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064107/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0093" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45585", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064107/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0093", "refsource": "MISC", "url": "https://kb.netgear.com/000064107/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0093" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45585", "datePublished": "2021-12-26T00:42:51", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.947Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45631
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.576Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:32:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45631", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504", "refsource": "MISC", "url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45631", "datePublished": "2021-12-26T00:32:49", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.576Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45508
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.286Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064133/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0490" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, and RBR850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:02:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064133/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0490" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45508", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, and RBR850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064133/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0490", "refsource": "MISC", "url": "https://kb.netgear.com/000064133/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0490" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45508", "datePublished": "2021-12-26T01:02:00", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.286Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45567
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.409Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064089/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0075" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:47:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064089/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0075" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45567", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064089/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0075", "refsource": "MISC", "url": "https://kb.netgear.com/000064089/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0075" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45567", "datePublished": "2021-12-26T00:47:20", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.409Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45589
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.276Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064111/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0097" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:42:09", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064111/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0097" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45589", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064111/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0097", "refsource": "MISC", "url": "https://kb.netgear.com/000064111/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0097" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45589", "datePublished": "2021-12-26T00:42:09", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.276Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-38518
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T01:44:22.826Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-11T00:02:50", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-38518", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528", "refsource": "MISC", "url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-38518", "datePublished": "2021-08-11T00:02:50", "dateReserved": "2021-08-10T00:00:00", "dateUpdated": "2024-08-04T01:44:22.826Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45505
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.275Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064129/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0477" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:02:31", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064129/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0477" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45505", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064129/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0477", "refsource": "MISC", "url": "https://kb.netgear.com/000064129/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0477" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45505", "datePublished": "2021-12-26T01:02:31", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.275Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45604
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.868Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064526/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2020-0572" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects CBR750 before 3.2.18.2, D6220 before 1.0.0.68, D6400 before 1.0.0.102, D8500 before 1.0.3.60, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:38:12", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064526/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2020-0572" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45604", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects CBR750 before 3.2.18.2, D6220 before 1.0.0.68, D6400 before 1.0.0.102, D8500 before 1.0.3.60, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:H/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064526/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2020-0572", "refsource": "MISC", "url": "https://kb.netgear.com/000064526/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2020-0572" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45604", "datePublished": "2021-12-26T00:38:12", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.868Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45621
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.926Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:34:50", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45621", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562", "refsource": "MISC", "url": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45621", "datePublished": "2021-12-26T00:34:50", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.926Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45563
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.382Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064084/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0066" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:48:39", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064084/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0066" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45563", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064084/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0066", "refsource": "MISC", "url": "https://kb.netgear.com/000064084/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0066" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45563", "datePublished": "2021-12-26T00:48:39", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.382Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14438
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.524Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:38:07", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14438", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14438", "datePublished": "2020-06-18T16:38:07", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.524Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-29079
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T21:55:12.662Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-23T06:59:01", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-29079", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470", "refsource": "MISC", "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-29079", "datePublished": "2021-03-23T06:59:01", "dateReserved": "2021-03-23T00:00:00", "dateUpdated": "2024-08-03T21:55:12.662Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45533
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.495Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects EX6120 before 1.0.0.66, EX6130 before 1.0.0.46, EX7000 before 1.0.1.106, EX7500 before 1.0.1.76, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, RBR850 before 4.6.3.9, RBS850 before 4.6.3.9, and RBK852 before 4.6.3.9." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:55:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45533", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects EX6120 before 1.0.0.66, EX6130 before 1.0.0.46, EX7000 before 1.0.1.106, EX7500 before 1.0.1.76, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, RBR850 before 4.6.3.9, RBS850 before 4.6.3.9, and RBK852 before 4.6.3.9." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062", "refsource": "MISC", "url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45533", "datePublished": "2021-12-26T00:55:13", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.495Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26926
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:23.102Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:27:22", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26926", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028", "refsource": "MISC", "url": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26926", "datePublished": "2020-10-09T06:27:22", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:23.102Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45665
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.863Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:26:16", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45665", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247", "refsource": "MISC", "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45665", "datePublished": "2021-12-26T00:26:16", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.863Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45558
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.456Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:50:36", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45558", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053", "refsource": "MISC", "url": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45558", "datePublished": "2021-12-26T00:50:36", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.456Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45669
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.783Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 3.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:25:28", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45669", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:N/C:L/I:L/PR:H/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210", "refsource": "MISC", "url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45669", "datePublished": "2021-12-26T00:25:28", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.783Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45617
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.873Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064505/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0156" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:35:36", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064505/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0156" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45617", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064505/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0156", "refsource": "MISC", "url": "https://kb.netgear.com/000064505/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0156" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45617", "datePublished": "2021-12-26T00:35:36", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.873Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45581
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.990Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064103/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0089" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:43:41", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064103/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0089" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45581", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064103/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0089", "refsource": "MISC", "url": "https://kb.netgear.com/000064103/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0089" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45581", "datePublished": "2021-12-26T00:43:41", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.990Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45583
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:00.593Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:43:13", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45583", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091", "refsource": "MISC", "url": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45583", "datePublished": "2021-12-26T00:43:13", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:00.593Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-26903
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T16:03:22.937Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062351/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0043" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-10-09T06:33:34", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062351/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0043" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-26903", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:L/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062351/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0043", "refsource": "MISC", "url": "https://kb.netgear.com/000062351/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0043" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-26903", "datePublished": "2020-10-09T06:33:34", "dateReserved": "2020-10-09T00:00:00", "dateUpdated": "2024-08-04T16:03:22.937Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27239
Vulnerability from cvelistv5
Vendor | Product | Version | |
---|---|---|---|
▼ | NETGEAR | Multiple Routers |
Version: firmware version 1.0.4.98 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.140Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-206/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062820/Security-Advisory-for-Stack-based-Buffer-Overflow-Remote-Code-Execution-Vulnerability-on-Some-Routers-PSV-2020-0432" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Multiple Routers", "vendor": "NETGEAR", "versions": [ { "status": "affected", "version": "firmware version 1.0.4.98" } ] } ], "credits": [ { "lang": "en", "value": "Anonymous" } ], "descriptions": [ { "lang": "en", "value": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6400 and R6700 firmware version 1.0.4.98 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the upnpd service, which listens on UDP port 1900 by default. A crafted MX header field in an SSDP message can trigger an overflow of a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-11851." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-03-29T21:05:29", "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "shortName": "zdi" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-206/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062820/Security-Advisory-for-Stack-based-Buffer-Overflow-Remote-Code-Execution-Vulnerability-on-Some-Routers-PSV-2020-0432" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "zdi-disclosures@trendmicro.com", "ID": "CVE-2021-27239", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Multiple Routers", "version": { "version_data": [ { "version_value": "firmware version 1.0.4.98" } ] } } ] }, "vendor_name": "NETGEAR" } ] } }, "credit": "Anonymous", "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6400 and R6700 firmware version 1.0.4.98 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the upnpd service, which listens on UDP port 1900 by default. A crafted MX header field in an SSDP message can trigger an overflow of a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-11851." } ] }, "impact": { "cvss": { "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-121: Stack-based Buffer Overflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-206/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-206/" }, { "name": "https://kb.netgear.com/000062820/Security-Advisory-for-Stack-based-Buffer-Overflow-Remote-Code-Execution-Vulnerability-on-Some-Routers-PSV-2020-0432", "refsource": "MISC", "url": "https://kb.netgear.com/000062820/Security-Advisory-for-Stack-based-Buffer-Overflow-Remote-Code-Execution-Vulnerability-on-Some-Routers-PSV-2020-0432" } ] } } } }, "cveMetadata": { "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e", "assignerShortName": "zdi", "cveId": "CVE-2021-27239", "datePublished": "2021-03-29T21:05:29", "dateReserved": "2021-02-16T00:00:00", "dateUpdated": "2024-08-03T20:48:16.140Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45666
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.842Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:26:06", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45666", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "ADJACENT", "availabilityImpact": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254", "refsource": "MISC", "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45666", "datePublished": "2021-12-26T00:26:06", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.842Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45506
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.518Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T01:02:20", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45506", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483", "refsource": "MISC", "url": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45506", "datePublished": "2021-12-26T01:02:20", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.518Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35796
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.177Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062717/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2020-0201" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects CBR40 before 2.5.0.10, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100 before 1.0.2.28, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150 before 1.0.0.46, EX6200 before 1.0.3.94, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6250 before 1.0.4.42, R6300v2 before 1.0.4.42, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v3 before 1.0.4.98, R6700 before 1.0.2.16, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.32, RAX50 before 1.0.2.32, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V-200 before 1.0.0.46, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3500RP before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, WNR3500Lv2 before 1.2.0.62, and XR300 before 1.0.3.50." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:29:49", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062717/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2020-0201" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35796", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects CBR40 before 2.5.0.10, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100 before 1.0.2.28, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150 before 1.0.0.46, EX6200 before 1.0.3.94, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6250 before 1.0.4.42, R6300v2 before 1.0.4.42, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v3 before 1.0.4.98, R6700 before 1.0.2.16, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.32, RAX50 before 1.0.2.32, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V-200 before 1.0.0.46, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3500RP before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, WNR3500Lv2 before 1.2.0.62, and XR300 before 1.0.3.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062717/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2020-0201", "refsource": "MISC", "url": "https://kb.netgear.com/000062717/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2020-0201" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35796", "datePublished": "2020-12-29T23:29:49", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.177Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45639
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:47:01.688Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:31:15", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45639", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "NONE", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121", "refsource": "MISC", "url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45639", "datePublished": "2021-12-26T00:31:15", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:47:01.688Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-45538
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T04:39:21.518Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000064088/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0074" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-12-26T00:54:22", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000064088/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0074" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-45538", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000064088/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0074", "refsource": "MISC", "url": "https://kb.netgear.com/000064088/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0074" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-45538", "datePublished": "2021-12-26T00:54:22", "dateReserved": "2021-12-25T00:00:00", "dateUpdated": "2024-08-04T04:39:21.518Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-35798
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T17:09:15.203Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://kb.netgear.com/000062715/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2019-0218" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6900P before 1.3.2.124, R7000 before 1.0.11.100, R7000P before 1.3.2.124, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7960P before 1.4.1.50, R8000 before 1.0.4.52, R7900P before 1.4.1.50, R8000P before 1.4.1.50, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.1.12, RAX45 before 1.0.2.66, RAX50 before 1.0.2.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RS400 before 1.5.0.48, and XR300 before 1.0.3.50." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 9.3, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-12-29T23:38:37", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://kb.netgear.com/000062715/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2019-0218" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-35798", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6900P before 1.3.2.124, R7000 before 1.0.11.100, R7000P before 1.3.2.124, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7960P before 1.4.1.50, R8000 before 1.0.4.52, R7900P before 1.4.1.50, R8000P before 1.4.1.50, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.1.12, RAX45 before 1.0.2.66, RAX50 before 1.0.2.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RS400 before 1.5.0.48, and XR300 before 1.0.3.50." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AC:L/AV:L/A:H/C:H/I:H/PR:N/S:C/UI:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000062715/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2019-0218", "refsource": "MISC", "url": "https://kb.netgear.com/000062715/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2019-0218" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-35798", "datePublished": "2020-12-29T23:38:37", "dateReserved": "2020-12-29T00:00:00", "dateUpdated": "2024-08-04T17:09:15.203Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-14432
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.433Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-18T16:33:29", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2020-14432", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." } ] }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT", "availabilityImpact": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049", "refsource": "CONFIRM", "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2020-14432", "datePublished": "2020-06-18T16:33:29", "dateReserved": "2020-06-18T00:00:00", "dateUpdated": "2024-08-04T12:46:34.433Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202103-1285
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1285", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29066" } ] }, "cve": "CVE-2021-29066", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-29066", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004914", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29066", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29066", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1362", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29066", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "VULMON", "id": "CVE-2021-29066" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29066", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004914", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1362", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29066", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "id": "VAR-202103-1285", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2023-12-18T13:27:48.054000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0484", "trust": 0.8, "url": "https://kb.netgear.com/000063014/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0484" }, { "title": "Netgear NETGEAR Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145683" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063014/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0484" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29066" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29066" }, { "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "db": "NVD", "id": "CVE-2021-29066" }, { "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29066" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "date": "2021-03-23T07:15:13.157000", "db": "NVD", "id": "CVE-2021-29066" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29066" }, { "date": "2021-12-02T07:31:00", "db": "JVNDB", "id": "JVNDB-2021-004914" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-29066" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1362" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1362" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Product authentication vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004914" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1362" } ], "trust": 0.6 } }
var-202112-2372
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2372", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "NVD", "id": "CVE-2021-45576" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45576" } ] }, "cve": "CVE-2021-45576", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45576", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45576", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45576", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45576", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2305", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45576", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45576" }, { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "NVD", "id": "CVE-2021-45576" }, { "db": "NVD", "id": "CVE-2021-45576" }, { "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45576" }, { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "VULMON", "id": "CVE-2021-45576" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45576", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016886", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2305", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45576", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45576" }, { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "NVD", "id": "CVE-2021-45576" }, { "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "id": "VAR-202112-2372", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:37:09.620000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0084", "trust": 0.8, "url": "https://kb.netgear.com/000064098/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0084" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177066" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "NVD", "id": "CVE-2021-45576" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064098/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0084" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45576" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45576" }, { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "NVD", "id": "CVE-2021-45576" }, { "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45576" }, { "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "db": "NVD", "id": "CVE-2021-45576" }, { "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45576" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "date": "2021-12-26T01:15:16.597000", "db": "NVD", "id": "CVE-2021-45576" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45576" }, { "date": "2022-12-26T05:57:00", "db": "JVNDB", "id": "JVNDB-2021-016886" }, { "date": "2022-01-04T20:42:33.217000", "db": "NVD", "id": "CVE-2021-45576" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2305" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2305" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016886" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2305" } ], "trust": 0.6 } }
var-202103-0938
Vulnerability from variot
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6400 and R6700 firmware version 1.0.4.98 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the upnpd service, which listens on UDP port 1900 by default. A crafted MX header field in an SSDP message can trigger an overflow of a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-11851. NETGEAR R6400 and R6700 A stack-based buffer overflow vulnerability exists in the firmware. Zero Day Initiative To this vulnerability ZDI-CAN-11851 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-0938", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.132" }, { "model": "wndr3400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.38" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.102" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.68" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.68" }, { "model": "r8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.88" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "r8300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.132" }, { "model": "wnr3500l", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.66" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.68" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.60" }, { "model": "r6300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.50" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "d7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.102" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.48" }, { "model": "rs400", "scope": "lte", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.68" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.56" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.94" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.54" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.102" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "ex7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6250", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dc112a", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "multiple routers", "scope": null, "trust": 0.7, "vendor": "netgear", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "NVD", "id": "CVE-2021-27239" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.5.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-27239" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Anonymous", "sources": [ { "db": "ZDI", "id": "ZDI-21-206" } ], "trust": 0.7 }, "cve": "CVE-2021-27239", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-27239", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "zdi-disclosures@trendmicro.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-27239", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-27239", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "NONE", "vectorString": "AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-27239", "trust": 1.8, "value": "HIGH" }, { "author": "zdi-disclosures@trendmicro.com", "id": "CVE-2021-27239", "trust": 1.0, "value": "HIGH" }, { "author": "ZDI", "id": "CVE-2021-27239", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1618", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-27239", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "VULMON", "id": "CVE-2021-27239" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "NVD", "id": "CVE-2021-27239" }, { "db": "NVD", "id": "CVE-2021-27239" }, { "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6400 and R6700 firmware version 1.0.4.98 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the upnpd service, which listens on UDP port 1900 by default. A crafted MX header field in an SSDP message can trigger an overflow of a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-11851. NETGEAR R6400 and R6700 A stack-based buffer overflow vulnerability exists in the firmware. Zero Day Initiative To this vulnerability ZDI-CAN-11851 Was numbered.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2021-27239" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "VULMON", "id": "CVE-2021-27239" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-27239", "trust": 3.2 }, { "db": "ZDI", "id": "ZDI-21-206", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2021-005006", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-11851", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202103-1618", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-27239", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "VULMON", "id": "CVE-2021-27239" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "NVD", "id": "CVE-2021-27239" }, { "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "id": "VAR-202103-0938", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35569712545454546 }, "last_update_date": "2023-12-18T12:49:18.489000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stack-based\u00a0Buffer\u00a0Overflow\u00a0Remote\u00a0Code\u00a0Execution\u00a0Vulnerability\u00a0on\u00a0Some\u00a0Routers,\u00a0PSV-2020-0432", "trust": 1.5, "url": "https://kb.netgear.com/000062820/security-advisory-for-stack-based-buffer-overflow-remote-code-execution-vulnerability-on-some-routers-psv-2020-0432" }, { "title": "Netgear NETGEAR R6400 and NETGEAR R6700 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=146570" }, { "title": "", "trust": 0.1, "url": "https://github.com/wizardsoftheinternet/cve-2021-27239 " } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "VULMON", "id": "CVE-2021-27239" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 }, { "problemtype": "Stack-based buffer overflow (CWE-121) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "NVD", "id": "CVE-2021-27239" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.6, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-206/" }, { "trust": 2.4, "url": "https://kb.netgear.com/000062820/security-advisory-for-stack-based-buffer-overflow-remote-code-execution-vulnerability-on-some-routers-psv-2020-0432" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27239" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/121.html" }, { "trust": 0.1, "url": "https://github.com/wizardsoftheinternet/cve-2021-27239" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "VULMON", "id": "CVE-2021-27239" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "NVD", "id": "CVE-2021-27239" }, { "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-206" }, { "db": "VULMON", "id": "CVE-2021-27239" }, { "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "db": "NVD", "id": "CVE-2021-27239" }, { "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-02-24T00:00:00", "db": "ZDI", "id": "ZDI-21-206" }, { "date": "2021-03-29T00:00:00", "db": "VULMON", "id": "CVE-2021-27239" }, { "date": "2021-12-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "date": "2021-03-29T21:15:12.377000", "db": "NVD", "id": "CVE-2021-27239" }, { "date": "2021-03-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-02-24T00:00:00", "db": "ZDI", "id": "ZDI-21-206" }, { "date": "2021-04-02T00:00:00", "db": "VULMON", "id": "CVE-2021-27239" }, { "date": "2021-12-06T05:23:00", "db": "JVNDB", "id": "JVNDB-2021-005006" }, { "date": "2021-04-02T14:03:08.407000", "db": "NVD", "id": "CVE-2021-27239" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1618" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1618" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR\u00a0R6400\u00a0 and \u00a0R6700\u00a0 Stack-based buffer overflow vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005006" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1618" } ], "trust": 0.6 } }
var-202112-2410
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2410", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "NVD", "id": "CVE-2021-45538" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45538" } ] }, "cve": "CVE-2021-45538", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45538", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45538", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45538", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45538", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2354", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45538", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45538" }, { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "NVD", "id": "CVE-2021-45538" }, { "db": "NVD", "id": "CVE-2021-45538" }, { "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45538" }, { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "VULMON", "id": "CVE-2021-45538" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45538", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016923", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2354", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45538", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45538" }, { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "NVD", "id": "CVE-2021-45538" }, { "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "id": "VAR-202112-2410", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:01:00.031000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0074", "trust": 0.8, "url": "https://kb.netgear.com/000064088/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0074" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177069" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "NVD", "id": "CVE-2021-45538" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064088/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0074" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45538" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45538" }, { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "NVD", "id": "CVE-2021-45538" }, { "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45538" }, { "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "db": "NVD", "id": "CVE-2021-45538" }, { "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45538" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "date": "2021-12-26T01:15:14.793000", "db": "NVD", "id": "CVE-2021-45538" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45538" }, { "date": "2022-12-27T03:00:00", "db": "JVNDB", "id": "JVNDB-2021-016923" }, { "date": "2022-01-04T22:11:21.620000", "db": "NVD", "id": "CVE-2021-45538" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2354" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2354" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016923" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2354" } ], "trust": 0.6 } }
var-202112-2385
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2385", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "NVD", "id": "CVE-2021-45563" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45563" } ] }, "cve": "CVE-2021-45563", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45563", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45563", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45563", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45563", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2287", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45563", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45563" }, { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "NVD", "id": "CVE-2021-45563" }, { "db": "NVD", "id": "CVE-2021-45563" }, { "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45563" }, { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "VULMON", "id": "CVE-2021-45563" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45563", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016898", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2287", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45563", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45563" }, { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "NVD", "id": "CVE-2021-45563" }, { "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "id": "VAR-202112-2385", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:22:38.138000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0066", "trust": 0.8, "url": "https://kb.netgear.com/000064084/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0066" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177050" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "NVD", "id": "CVE-2021-45563" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064084/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0066" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45563" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45563" }, { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "NVD", "id": "CVE-2021-45563" }, { "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45563" }, { "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "db": "NVD", "id": "CVE-2021-45563" }, { "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45563" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "date": "2021-12-26T01:15:15.993000", "db": "NVD", "id": "CVE-2021-45563" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45563" }, { "date": "2022-12-26T08:00:00", "db": "JVNDB", "id": "JVNDB-2021-016898" }, { "date": "2022-01-04T19:34:52.370000", "db": "NVD", "id": "CVE-2021-45563" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2287" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2287" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016898" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2287" } ], "trust": 0.6 } }
var-202112-2310
Vulnerability from variot
Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.32, EAX80 prior to 1.0.1.62, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7000 prior to 1.0.1.104, EX7500 prior to 1.0.0.72, R7000 prior to 1.0.11.110, R7900 prior to 1.0.4.30, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.62, RAX200 prior to 1.0.2.102, XR300 prior to 1.0.3.50, EX3700 prior to 1.0.0.90, MR60 prior to 1.0.5.102, R7000P prior to 1.3.2.126, R8000P prior to 1.4.1.66, RAX20 prior to 1.0.1.64, RAX50 prior to 1.0.2.28, RAX80 prior to 1.0.3.102, EX3800 prior to 1.0.0.90, MS60 prior to 1.0.5.102, R6900P prior to 1.3.2.126, R7900P prior to 1.4.1.66, RAX15 prior to 1.0.1.64, RAX45 prior to 1.0.2.28, RAX75 prior to 1.0.3.102, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2310", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.32" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.30" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.102" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.104" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.28" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.110" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.28" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.62" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6130", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "NVD", "id": "CVE-2021-45639" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.104", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.30", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45639" } ] }, "cve": "CVE-2021-45639", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "exploitabilityScore": 8.6, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45639", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.1, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.1, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45639", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45639", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45639", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2435", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45639", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45639" }, { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "NVD", "id": "CVE-2021-45639" }, { "db": "NVD", "id": "CVE-2021-45639" }, { "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.32, EAX80 prior to 1.0.1.62, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7000 prior to 1.0.1.104, EX7500 prior to 1.0.0.72, R7000 prior to 1.0.11.110, R7900 prior to 1.0.4.30, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.62, RAX200 prior to 1.0.2.102, XR300 prior to 1.0.3.50, EX3700 prior to 1.0.0.90, MR60 prior to 1.0.5.102, R7000P prior to 1.3.2.126, R8000P prior to 1.4.1.66, RAX20 prior to 1.0.1.64, RAX50 prior to 1.0.2.28, RAX80 prior to 1.0.3.102, EX3800 prior to 1.0.0.90, MS60 prior to 1.0.5.102, R6900P prior to 1.3.2.126, R7900P prior to 1.4.1.66, RAX15 prior to 1.0.1.64, RAX45 prior to 1.0.2.28, RAX75 prior to 1.0.3.102, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45639" }, { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "VULMON", "id": "CVE-2021-45639" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45639", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017174", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2435", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45639", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45639" }, { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "NVD", "id": "CVE-2021-45639" }, { "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "id": "VAR-202112-2310", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.31718036470588234 }, "last_update_date": "2023-12-18T12:26:30.362000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Reflected\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0121", "trust": 0.8, "url": "https://kb.netgear.com/000064460/security-advisory-for-reflected-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0121" }, { "title": "Netgear RBR750 and NETGEAR Fixes for cross-site scripting vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176673" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "NVD", "id": "CVE-2021-45639" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064460/security-advisory-for-reflected-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0121" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45639" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45639" }, { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "NVD", "id": "CVE-2021-45639" }, { "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45639" }, { "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "db": "NVD", "id": "CVE-2021-45639" }, { "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45639" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "date": "2021-12-26T01:15:19.597000", "db": "NVD", "id": "CVE-2021-45639" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45639" }, { "date": "2023-01-06T06:05:00", "db": "JVNDB", "id": "JVNDB-2021-017174" }, { "date": "2022-01-06T14:53:06.103000", "db": "NVD", "id": "CVE-2021-45639" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2435" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2435" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017174" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2435" } ], "trust": 0.6 } }
var-202010-0918
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0918", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "NVD", "id": "CVE-2020-26928" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26928" } ] }, "cve": "CVE-2020-26928", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26928", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-012205", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26928", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2020-26928", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-359", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "NVD", "id": "CVE-2020-26928" }, { "db": "NVD", "id": "CVE-2020-26928" }, { "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26928" }, { "db": "JVNDB", "id": "JVNDB-2020-012205" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26928", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012205", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-359", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "NVD", "id": "CVE-2020-26928" }, { "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "id": "VAR-202010-0918", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:27:12.878000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0027", "trust": 0.8, "url": "https://kb.netgear.com/000062324/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0027" }, { "title": "Multiple NETGEAR Product Authorization Issue Vulnerability Fixing Measures", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131143" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "NVD", "id": "CVE-2020-26928" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062324/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0027" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26928" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "NVD", "id": "CVE-2020-26928" }, { "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "db": "NVD", "id": "CVE-2020-26928" }, { "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "date": "2020-10-09T07:15:18.403000", "db": "NVD", "id": "CVE-2020-26928" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:37:00", "db": "JVNDB", "id": "JVNDB-2020-012205" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26928" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-359" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-359" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Authentication vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012205" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-359" } ], "trust": 0.6 } }
var-202103-1279
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1279", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29076" } ] }, "cve": "CVE-2021-29076", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29076", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004909", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29076", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29076", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1347", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29076", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "VULMON", "id": "CVE-2021-29076" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29076", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004909", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1347", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29076", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "id": "VAR-202103-1279", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2023-12-18T13:07:16.007000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0485", "trust": 0.8, "url": "https://kb.netgear.com/000063015/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0485" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145677" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063015/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0485" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29076" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29076" }, { "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "db": "NVD", "id": "CVE-2021-29076" }, { "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29076" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "date": "2021-03-23T07:15:13.920000", "db": "NVD", "id": "CVE-2021-29076" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29076" }, { "date": "2021-12-02T06:23:00", "db": "JVNDB", "id": "JVNDB-2021-004909" }, { "date": "2021-03-26T14:07:06.697000", "db": "NVD", "id": "CVE-2021-29076" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1347" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1347" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004909" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1347" } ], "trust": 0.6 } }
var-202112-2328
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 3.2.18.2, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX3700 prior to 1.0.0.94, EX3800 prior to 1.0.0.94, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7000 prior to 1.0.1.104, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6300v2 prior to 1.0.4.52, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.106, R6700v3 prior to 1.0.4.106, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7100LG prior to 1.0.0.72, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, R8300 prior to 1.0.2.154, R8500 prior to 1.0.2.154, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2328", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.106" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.18.2" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.94" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "r8300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.154" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.68" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.46" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.94" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.104" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "r8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.154" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r6300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.52" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.126" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.106" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax35v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax40v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax15", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax43", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "NVD", "id": "CVE-2021-45621" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.104", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45621" } ] }, "cve": "CVE-2021-45621", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45621", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45621", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45621", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45621", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2417", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "NVD", "id": "CVE-2021-45621" }, { "db": "NVD", "id": "CVE-2021-45621" }, { "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 3.2.18.2, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX3700 prior to 1.0.0.94, EX3800 prior to 1.0.0.94, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7000 prior to 1.0.1.104, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6300v2 prior to 1.0.4.52, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.106, R6700v3 prior to 1.0.4.106, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7100LG prior to 1.0.0.72, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, R8300 prior to 1.0.2.154, R8500 prior to 1.0.2.154, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68", "sources": [ { "db": "NVD", "id": "CVE-2021-45621" }, { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "VULMON", "id": "CVE-2021-45621" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45621", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017547", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2417", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45621", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45621" }, { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "NVD", "id": "CVE-2021-45621" }, { "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "id": "VAR-202112-2328", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3619391425925926 }, "last_update_date": "2023-12-18T12:42:08.989000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0562", "trust": 0.8, "url": "https://kb.netgear.com/000064523/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0562" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176396" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "NVD", "id": "CVE-2021-45621" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064523/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0562" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45621" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45621" }, { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "NVD", "id": "CVE-2021-45621" }, { "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45621" }, { "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "db": "NVD", "id": "CVE-2021-45621" }, { "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45621" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "date": "2021-12-26T01:15:18.757000", "db": "NVD", "id": "CVE-2021-45621" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45621" }, { "date": "2023-01-25T02:07:00", "db": "JVNDB", "id": "JVNDB-2021-017547" }, { "date": "2022-01-10T15:54:42.697000", "db": "NVD", "id": "CVE-2021-45621" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2417" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2417" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017547" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2417" } ], "trust": 0.6 } }
var-202006-0586
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0586", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14428" } ] }, "cve": "CVE-2020-14428", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006749", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-62723", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006749", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14428", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14428", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006749", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-62723", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1241", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNVD", "id": "CNVD-2021-62723" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14428", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006749", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-62723", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1241", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "id": "VAR-202006-0586", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" } ] }, "last_update_date": "2023-12-18T12:27:27.714000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0044", "trust": 0.8, "url": "https://kb.netgear.com/000061936/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0044" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-62723)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275116" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121990" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14428" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061936/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0044" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14428" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-62723" }, { "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "db": "NVD", "id": "CVE-2020-14428" }, { "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-62723" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "date": "2020-06-18T17:15:12", "db": "NVD", "id": "CVE-2020-14428" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-17T00:00:00", "db": "CNVD", "id": "CNVD-2021-62723" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006749" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14428" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1241" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1241" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006749" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1241" } ], "trust": 0.6 } }
var-202112-2314
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2314", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "NVD", "id": "CVE-2021-45635" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45635" } ] }, "cve": "CVE-2021-45635", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45635", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45635", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45635", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45635", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2430", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45635", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45635" }, { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "NVD", "id": "CVE-2021-45635" }, { "db": "NVD", "id": "CVE-2021-45635" }, { "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45635" }, { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "VULMON", "id": "CVE-2021-45635" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45635", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017036", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2430", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45635", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45635" }, { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "NVD", "id": "CVE-2021-45635" }, { "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "id": "VAR-202112-2314", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:27:28.921000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0491", "trust": 0.8, "url": "https://kb.netgear.com/000064134/security-advisory-for-pre-authentication-command-injection-on-wifi-systems-psv-2020-0491" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176668" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "NVD", "id": "CVE-2021-45635" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064134/security-advisory-for-pre-authentication-command-injection-on-wifi-systems-psv-2020-0491" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45635" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45635" }, { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "NVD", "id": "CVE-2021-45635" }, { "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45635" }, { "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "db": "NVD", "id": "CVE-2021-45635" }, { "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45635" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "date": "2021-12-26T01:15:19.413000", "db": "NVD", "id": "CVE-2021-45635" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45635" }, { "date": "2022-12-28T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017036" }, { "date": "2022-01-05T17:40:34.343000", "db": "NVD", "id": "CVE-2021-45635" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2430" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2430" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017036" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2430" } ], "trust": 0.6 } }
var-202112-2365
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2365", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "NVD", "id": "CVE-2021-45583" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45583" } ] }, "cve": "CVE-2021-45583", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45583", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45583", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45583", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45583", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2379", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45583", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45583" }, { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "NVD", "id": "CVE-2021-45583" }, { "db": "NVD", "id": "CVE-2021-45583" }, { "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45583" }, { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "VULMON", "id": "CVE-2021-45583" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45583", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016914", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2379", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45583", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45583" }, { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "NVD", "id": "CVE-2021-45583" }, { "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "id": "VAR-202112-2365", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:17:34.440000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0091", "trust": 0.8, "url": "https://kb.netgear.com/000064105/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0091" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177091" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "NVD", "id": "CVE-2021-45583" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064105/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0091" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45583" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45583" }, { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "NVD", "id": "CVE-2021-45583" }, { "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45583" }, { "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "db": "NVD", "id": "CVE-2021-45583" }, { "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45583" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "date": "2021-12-26T01:15:16.933000", "db": "NVD", "id": "CVE-2021-45583" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45583" }, { "date": "2022-12-27T02:13:00", "db": "JVNDB", "id": "JVNDB-2021-016914" }, { "date": "2022-01-04T20:34:26.323000", "db": "NVD", "id": "CVE-2021-45583" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2379" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2379" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016914" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2379" } ], "trust": 0.6 } }
var-202010-0563
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The product contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0563", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "NVD", "id": "CVE-2020-26897" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26897" } ] }, "cve": "CVE-2020-26897", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-26897", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26897", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26897", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26897", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-327", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "NVD", "id": "CVE-2020-26897" }, { "db": "NVD", "id": "CVE-2020-26897" }, { "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The product contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26897" }, { "db": "JVNDB", "id": "JVNDB-2020-012470" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26897", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012470", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-327", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "NVD", "id": "CVE-2020-26897" }, { "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "id": "VAR-202010-0563", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:27:13.239000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0045", "trust": 0.8, "url": "https://kb.netgear.com/000062357/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0045" }, { "title": "NETGEAR RBR750 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=129622" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "NVD", "id": "CVE-2020-26897" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062357/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0045" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26897" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "NVD", "id": "CVE-2020-26897" }, { "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "db": "NVD", "id": "CVE-2020-26897" }, { "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "date": "2020-10-09T07:15:12.450000", "db": "NVD", "id": "CVE-2020-26897" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-05-10T05:45:00", "db": "JVNDB", "id": "JVNDB-2020-012470" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26897" }, { "date": "2020-10-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-327" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-327" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials in products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012470" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-327" } ], "trust": 0.6 } }
var-202103-1282
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1282", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29079" } ] }, "cve": "CVE-2021-29079", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29079", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004584", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29079", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29079", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1344", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29079", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "VULMON", "id": "CVE-2021-29079" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29079", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004584", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1344", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29079", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "id": "VAR-202103-1282", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2023-12-18T13:17:54.168000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0470", "trust": 0.8, "url": "https://kb.netgear.com/000063020/security-advisory-for-pre-authentication-command-injection-some-wifi-routers-psv-2020-0470" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145160" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063020/security-advisory-for-pre-authentication-command-injection-some-wifi-routers-psv-2020-0470" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29079" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29079" }, { "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "db": "NVD", "id": "CVE-2021-29079" }, { "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29079" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "date": "2021-03-23T07:15:14.157000", "db": "NVD", "id": "CVE-2021-29079" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29079" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004584" }, { "date": "2021-03-24T19:14:30.177000", "db": "NVD", "id": "CVE-2021-29079" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1344" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1344" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004584" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1344" } ], "trust": 0.6 } }
var-202112-2217
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBR852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2217", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45504" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45504" } ] }, "cve": "CVE-2021-45504", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-45504", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "HIGH", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-45504", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45504", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2348", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45504", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45504" }, { "db": "CNNVD", "id": "CNNVD-202112-2348" }, { "db": "NVD", "id": "CVE-2021-45504" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBR852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45504" }, { "db": "VULMON", "id": "CVE-2021-45504" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45504", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2348", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45504", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45504" }, { "db": "CNNVD", "id": "CNNVD-202112-2348" }, { "db": "NVD", "id": "CVE-2021-45504" } ] }, "id": "VAR-202112-2217", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.23069138 }, "last_update_date": "2022-05-04T10:07:01.182000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176146" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2348" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45504" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064128/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0475" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45504" }, { "db": "CNNVD", "id": "CNNVD-202112-2348" }, { "db": "NVD", "id": "CVE-2021-45504" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45504" }, { "db": "CNNVD", "id": "CNNVD-202112-2348" }, { "db": "NVD", "id": "CVE-2021-45504" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45504" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2348" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45504" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45504" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2348" }, { "date": "2022-01-05T13:29:00", "db": "NVD", "id": "CVE-2021-45504" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2348" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Authorization problem vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2348" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2348" } ], "trust": 0.6 } }
var-202112-2333
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 3.2.18.2, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, and XR1000 prior to 1.0.0.58
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2333", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.18.2" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.68" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.126" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.46" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "NVD", "id": "CVE-2021-45616" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45616" } ] }, "cve": "CVE-2021-45616", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45616", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45616", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45616", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45616", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2415", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45616", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45616" }, { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "NVD", "id": "CVE-2021-45616" }, { "db": "NVD", "id": "CVE-2021-45616" }, { "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 3.2.18.2, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, and XR1000 prior to 1.0.0.58", "sources": [ { "db": "NVD", "id": "CVE-2021-45616" }, { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "VULMON", "id": "CVE-2021-45616" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45616", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017551", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2415", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45616", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45616" }, { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "NVD", "id": "CVE-2021-45616" }, { "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "id": "VAR-202112-2333", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.30832592928571423 }, "last_update_date": "2023-12-18T13:42:20.146000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0576", "trust": 0.8, "url": "https://kb.netgear.com/000064527/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0576" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176394" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "NVD", "id": "CVE-2021-45616" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064527/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0576" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45616" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45616" }, { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "NVD", "id": "CVE-2021-45616" }, { "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45616" }, { "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "db": "NVD", "id": "CVE-2021-45616" }, { "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45616" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "date": "2021-12-26T01:15:18.520000", "db": "NVD", "id": "CVE-2021-45616" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-07T00:00:00", "db": "VULMON", "id": "CVE-2021-45616" }, { "date": "2023-01-25T05:10:00", "db": "JVNDB", "id": "JVNDB-2021-017551" }, { "date": "2022-01-07T19:45:36.140000", "db": "NVD", "id": "CVE-2021-45616" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2415" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2415" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017551" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2415" } ], "trust": 0.6 } }
var-202112-2387
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2387", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "NVD", "id": "CVE-2021-45561" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45561" } ] }, "cve": "CVE-2021-45561", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45561", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45561", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45561", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45561", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2292", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45561", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45561" }, { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "NVD", "id": "CVE-2021-45561" }, { "db": "NVD", "id": "CVE-2021-45561" }, { "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45561" }, { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "VULMON", "id": "CVE-2021-45561" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45561", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016904", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2292", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45561", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45561" }, { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "NVD", "id": "CVE-2021-45561" }, { "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "id": "VAR-202112-2387", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:34:42.179000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0059", "trust": 0.8, "url": "https://kb.netgear.com/000064165/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0059" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177054" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "NVD", "id": "CVE-2021-45561" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064165/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0059" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45561" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45561" }, { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "NVD", "id": "CVE-2021-45561" }, { "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45561" }, { "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "db": "NVD", "id": "CVE-2021-45561" }, { "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45561" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "date": "2021-12-26T01:15:15.893000", "db": "NVD", "id": "CVE-2021-45561" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45561" }, { "date": "2022-12-26T08:51:00", "db": "JVNDB", "id": "JVNDB-2021-016904" }, { "date": "2022-01-04T20:05:34.997000", "db": "NVD", "id": "CVE-2021-45561" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2292" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2292" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016904" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2292" } ], "trust": 0.6 } }
var-202006-0930
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0930", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14433" } ] }, "cve": "CVE-2020-14433", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006744", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2021-44778", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006744", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14433", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-14433", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-006744", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-44778", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1248", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNVD", "id": "CNVD-2021-44778" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14433", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006744", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44778", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1248", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "id": "VAR-202006-0930", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" } ] }, "last_update_date": "2023-12-18T12:35:29.918000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Command Injection on Some WiFi Systems, PSV-2020-0035", "trust": 0.8, "url": "https://kb.netgear.com/000061932/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0035" }, { "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44778)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275096" }, { "title": "Multiple NETGEAR Product Command Injection Vulnerability Fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121996" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14433" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061932/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0035" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14433" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44778" }, { "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "db": "NVD", "id": "CVE-2020-14433" }, { "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44778" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "date": "2020-06-18T17:15:12.453000", "db": "NVD", "id": "CVE-2020-14433" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44778" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006744" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14433" }, { "date": "2020-06-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1248" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1248" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006744" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1248" } ], "trust": 0.6 } }
var-202006-0938
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands on the system with a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0938", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14441" } ] }, "cve": "CVE-2020-14441", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006682", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44786", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14441", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006682", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14441", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14441", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006682", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44786", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1260", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14441", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands on the system with a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14441", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2020-006682", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44786", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1260", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14441", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "id": "VAR-202006-0938", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" } ] }, "last_update_date": "2024-02-13T23:00:56.963000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0071", "trust": 0.8, "url": "https://kb.netgear.com/000061946/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0071" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44786)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275051" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14441" }, { "trust": 1.7, "url": "https://kb.netgear.com/000061946/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0071" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14441" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44786" }, { "db": "VULMON", "id": "CVE-2020-14441" }, { "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "db": "NVD", "id": "CVE-2020-14441" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44786" }, { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14441" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "date": "2020-06-18T17:15:13.233000", "db": "NVD", "id": "CVE-2020-14441" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44786" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14441" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006682" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1260" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14441" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1260" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006682" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1260" } ], "trust": 0.6 } }
var-202012-1193
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1193", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "NVD", "id": "CVE-2020-35794" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-35794" } ] }, "cve": "CVE-2020-35794", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-35794", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-35794", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-35794", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-35794", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202012-1765", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "NVD", "id": "CVE-2020-35794" }, { "db": "NVD", "id": "CVE-2020-35794" }, { "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-35794" }, { "db": "JVNDB", "id": "JVNDB-2020-014792" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35794", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-014792", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1765", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "NVD", "id": "CVE-2020-35794" }, { "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "id": "VAR-202012-1193", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:49:23.047000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0034", "trust": 0.8, "url": "https://kb.netgear.com/000062629/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0034" }, { "title": "Multiple Netgear Product Command Injection Vulnerability Fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138272" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "NVD", "id": "CVE-2020-35794" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062629/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0034" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35794" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "NVD", "id": "CVE-2020-35794" }, { "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "db": "NVD", "id": "CVE-2020-35794" }, { "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-31T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "date": "2020-12-30T00:15:14.017000", "db": "NVD", "id": "CVE-2020-35794" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-31T05:13:00", "db": "JVNDB", "id": "JVNDB-2020-014792" }, { "date": "2020-12-30T21:23:57.013000", "db": "NVD", "id": "CVE-2020-35794" }, { "date": "2021-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1765" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1765" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014792" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1765" } ], "trust": 0.6 } }
var-202010-0576
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0576", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "NVD", "id": "CVE-2020-26910" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26910" } ] }, "cve": "CVE-2020-26910", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26910", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26910", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26910", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-26910", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202010-341", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "NVD", "id": "CVE-2020-26910" }, { "db": "NVD", "id": "CVE-2020-26910" }, { "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26910" }, { "db": "JVNDB", "id": "JVNDB-2020-012218" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26910", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012218", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-341", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "NVD", "id": "CVE-2020-26910" }, { "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "id": "VAR-202010-0576", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:23:08.052000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0031", "trust": 0.8, "url": "https://kb.netgear.com/000062343/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0031" }, { "title": "Multiple NETGEAR Product Command Injection Vulnerability Fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131128" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "NVD", "id": "CVE-2020-26910" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062343/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0031" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26910" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "NVD", "id": "CVE-2020-26910" }, { "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "db": "NVD", "id": "CVE-2020-26910" }, { "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "date": "2020-10-09T07:15:16.857000", "db": "NVD", "id": "CVE-2020-26910" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:42:00", "db": "JVNDB", "id": "JVNDB-2020-012218" }, { "date": "2020-10-16T18:10:17.637000", "db": "NVD", "id": "CVE-2020-26910" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-341" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-341" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012218" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-341" } ], "trust": 0.6 } }
var-202012-1194
Vulnerability from variot
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1194", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "cbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "r7400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.60" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "r6700v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.74" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.106" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.136" }, { "model": "r6260", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "r6900v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.102" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "ac2400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r7450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "rbr10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "r6800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.48" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "r7350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "r6330", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "r6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "ac2100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.58" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.58" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbs10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "ac2600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r7200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "r6350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk12", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "ac2400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbk40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ac2600", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ac2100", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "NVD", "id": "CVE-2020-35795" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbk40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6330:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk12:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-35795" } ] }, "cve": "CVE-2020-35795", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-35795", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-015039", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-35795", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2020-35795", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202012-1750", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "NVD", "id": "CVE-2020-35795" }, { "db": "NVD", "id": "CVE-2020-35795" }, { "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-35795" }, { "db": "JVNDB", "id": "JVNDB-2020-015039" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35795", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-015039", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1750", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "NVD", "id": "CVE-2020-35795" }, { "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "id": "VAR-202012-1194", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.33538940590909083 }, "last_update_date": "2023-12-18T12:16:40.737000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Range\u00a0Extenders,\u00a0and\u00a0Orbi\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0154", "trust": 0.8, "url": "https://kb.netgear.com/000062735/security-advisory-for-pre-authentication-buffer-overflow-on-some-routers-range-extenders-and-orbi-wifi-systems-psv-2020-0154" }, { "title": "Certain NETGEAR devices Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138129" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "NVD", "id": "CVE-2020-35795" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062735/security-advisory-for-pre-authentication-buffer-overflow-on-some-routers-range-extenders-and-orbi-wifi-systems-psv-2020-0154" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35795" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "NVD", "id": "CVE-2020-35795" }, { "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "db": "NVD", "id": "CVE-2020-35795" }, { "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "date": "2020-12-30T00:15:14.080000", "db": "NVD", "id": "CVE-2020-35795" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-08T08:43:00", "db": "JVNDB", "id": "JVNDB-2020-015039" }, { "date": "2021-01-04T14:43:53.907000", "db": "NVD", "id": "CVE-2020-35795" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1750" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1750" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015039" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1750" } ], "trust": 0.6 } }
var-202112-2280
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2280", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax15", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax45", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "NVD", "id": "CVE-2021-45669" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45669" } ] }, "cve": "CVE-2021-45669", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45669", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 3.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "exploitabilityScore": 0.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45669", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45669", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45669", "trust": 1.0, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202112-2470", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45669", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45669" }, { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "NVD", "id": "CVE-2021-45669" }, { "db": "NVD", "id": "CVE-2021-45669" }, { "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45669" }, { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "VULMON", "id": "CVE-2021-45669" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45669", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017170", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2470", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45669", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45669" }, { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "NVD", "id": "CVE-2021-45669" }, { "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "id": "VAR-202112-2280", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26652449666666667 }, "last_update_date": "2023-12-18T13:22:38.263000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0210", "trust": 0.8, "url": "https://kb.netgear.com/000064478/security-advisory-for-stored-cross-site-scripting-on-some-routers-and-wifi-systems-psv-2020-0210" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=175895" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "NVD", "id": "CVE-2021-45669" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064478/security-advisory-for-stored-cross-site-scripting-on-some-routers-and-wifi-systems-psv-2020-0210" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45669" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45669" }, { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "NVD", "id": "CVE-2021-45669" }, { "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45669" }, { "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "db": "NVD", "id": "CVE-2021-45669" }, { "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45669" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "date": "2021-12-26T01:15:20.960000", "db": "NVD", "id": "CVE-2021-45669" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45669" }, { "date": "2023-01-06T05:15:00", "db": "JVNDB", "id": "JVNDB-2021-017170" }, { "date": "2022-01-06T14:52:19.623000", "db": "NVD", "id": "CVE-2021-45669" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2470" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2470" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017170" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2470" } ], "trust": 0.6 } }
var-202010-0566
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0566", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "NVD", "id": "CVE-2020-26900" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26900" } ] }, "cve": "CVE-2020-26900", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26900", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26900", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26900", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26900", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-330", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "NVD", "id": "CVE-2020-26900" }, { "db": "NVD", "id": "CVE-2020-26900" }, { "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26900" }, { "db": "JVNDB", "id": "JVNDB-2020-012225" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26900", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012225", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-330", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "NVD", "id": "CVE-2020-26900" }, { "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "id": "VAR-202010-0566", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:42:46.269000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0032", "trust": 0.8, "url": "https://kb.netgear.com/000062354/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0032" }, { "title": "Multiple NETGEAR Repair measures for device security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131119" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "NVD", "id": "CVE-2020-26900" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062354/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0032" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26900" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "NVD", "id": "CVE-2020-26900" }, { "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "db": "NVD", "id": "CVE-2020-26900" }, { "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "date": "2020-10-09T07:15:14.370000", "db": "NVD", "id": "CVE-2020-26900" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:46:00", "db": "JVNDB", "id": "JVNDB-2020-012225" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26900" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-330" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-330" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials on devices Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012225" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-330" } ], "trust": 0.6 } }
var-202112-2403
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2403", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "NVD", "id": "CVE-2021-45545" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45545" } ] }, "cve": "CVE-2021-45545", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45545", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45545", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45545", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45545", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2362", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45545", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45545" }, { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "NVD", "id": "CVE-2021-45545" }, { "db": "NVD", "id": "CVE-2021-45545" }, { "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45545" }, { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "VULMON", "id": "CVE-2021-45545" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45545", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016926", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2362", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45545", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45545" }, { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "NVD", "id": "CVE-2021-45545" }, { "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "id": "VAR-202112-2403", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3106649133333334 }, "last_update_date": "2023-12-18T13:32:23.517000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0557", "trust": 0.8, "url": "https://kb.netgear.com/000064522/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0557" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177071" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "NVD", "id": "CVE-2021-45545" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064522/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0557" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45545" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45545" }, { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "NVD", "id": "CVE-2021-45545" }, { "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45545" }, { "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "db": "NVD", "id": "CVE-2021-45545" }, { "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45545" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "date": "2021-12-26T01:15:15.133000", "db": "NVD", "id": "CVE-2021-45545" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45545" }, { "date": "2022-12-27T03:09:00", "db": "JVNDB", "id": "JVNDB-2021-016926" }, { "date": "2022-01-04T22:09:07.277000", "db": "NVD", "id": "CVE-2021-45545" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2362" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2362" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016926" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2362" } ], "trust": 0.6 } }
var-202112-2377
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2377", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "NVD", "id": "CVE-2021-45571" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45571" } ] }, "cve": "CVE-2021-45571", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45571", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45571", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45571", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45571", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2299", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45571", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45571" }, { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "NVD", "id": "CVE-2021-45571" }, { "db": "NVD", "id": "CVE-2021-45571" }, { "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45571" }, { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "VULMON", "id": "CVE-2021-45571" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45571", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016890", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2299", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45571", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45571" }, { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "NVD", "id": "CVE-2021-45571" }, { "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "id": "VAR-202112-2377", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:42:20.075000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0079", "trust": 0.8, "url": "https://kb.netgear.com/000064093/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0079" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177061" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "NVD", "id": "CVE-2021-45571" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064093/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0079" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45571" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45571" }, { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "NVD", "id": "CVE-2021-45571" }, { "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45571" }, { "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "db": "NVD", "id": "CVE-2021-45571" }, { "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45571" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "date": "2021-12-26T01:15:16.370000", "db": "NVD", "id": "CVE-2021-45571" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45571" }, { "date": "2022-12-26T07:11:00", "db": "JVNDB", "id": "JVNDB-2021-016890" }, { "date": "2022-01-04T19:47:38.853000", "db": "NVD", "id": "CVE-2021-45571" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2299" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2299" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016890" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2299" } ], "trust": 0.6 } }
var-202010-0571
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0571", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "NVD", "id": "CVE-2020-26905" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26905" } ] }, "cve": "CVE-2020-26905", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26905", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26905", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26905", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26905", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-336", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "NVD", "id": "CVE-2020-26905" }, { "db": "NVD", "id": "CVE-2020-26905" }, { "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26905" }, { "db": "JVNDB", "id": "JVNDB-2020-012223" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26905", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012223", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-336", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "NVD", "id": "CVE-2020-26905" }, { "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "id": "VAR-202010-0571", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:07:26.910000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0047", "trust": 0.8, "url": "https://kb.netgear.com/000062349/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0047" }, { "title": "Multiple NETGEAR Repair measures for device security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131123" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "NVD", "id": "CVE-2020-26905" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062349/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0047" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26905" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "NVD", "id": "CVE-2020-26905" }, { "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "db": "NVD", "id": "CVE-2020-26905" }, { "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "date": "2020-10-09T07:15:16.293000", "db": "NVD", "id": "CVE-2020-26905" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:44:00", "db": "JVNDB", "id": "JVNDB-2020-012223" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26905" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-336" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-336" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials on devices Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012223" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-336" } ], "trust": 0.6 } }
var-202103-1283
Vulnerability from variot
Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126. plural NETGEAR A vulnerability exists in the device regarding the password management function.Information may be obtained and information may be tampered with. This affects RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR854 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, R7000 prior to 1.0.11.116, R6900P prior to 1.3.2.126, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, R7900P prior to 1.4.1.66, R8000P prior to 1.4.1.66, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, and R7000P prior to 1.3.2.126
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1283", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "rbr854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.66" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29080" } ] }, "cve": "CVE-2021-29080", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 4.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29080", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 8.1, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004585", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29080", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29080", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1343", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29080", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126. plural NETGEAR A vulnerability exists in the device regarding the password management function.Information may be obtained and information may be tampered with. This affects RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR854 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, R7000 prior to 1.0.11.116, R6900P prior to 1.3.2.126, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, R7900P prior to 1.4.1.66, R8000P prior to 1.4.1.66, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, and R7000P prior to 1.3.2.126", "sources": [ { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "VULMON", "id": "CVE-2021-29080" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29080", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004585", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1343", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29080", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "id": "VAR-202103-1283", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.33196480249999993 }, "last_update_date": "2023-12-18T12:26:55.653000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-authentication\u00a0Password\u00a0Reset\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0150", "trust": 0.8, "url": "https://kb.netgear.com/000063007/security-advisory-for-pre-authentication-password-reset-on-some-routers-and-wifi-systems-psv-2019-0150" }, { "title": "Certain NETGEAR Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145159" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-640", "trust": 1.0 }, { "problemtype": "Weak password recovery mechanism when you forget your password (CWE-640) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063007/security-advisory-for-pre-authentication-password-reset-on-some-routers-and-wifi-systems-psv-2019-0150" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29080" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/640.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29080" }, { "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "db": "NVD", "id": "CVE-2021-29080" }, { "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29080" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "date": "2021-03-23T07:15:14.217000", "db": "NVD", "id": "CVE-2021-29080" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29080" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004585" }, { "date": "2021-03-24T19:13:48.800000", "db": "NVD", "id": "CVE-2021-29080" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1343" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1343" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerability related to password management function in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004585" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1343" } ], "trust": 0.6 } }
var-202010-0569
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0569", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "NVD", "id": "CVE-2020-26903" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26903" } ] }, "cve": "CVE-2020-26903", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26903", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26903", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26903", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26903", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-334", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "NVD", "id": "CVE-2020-26903" }, { "db": "NVD", "id": "CVE-2020-26903" }, { "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26903" }, { "db": "JVNDB", "id": "JVNDB-2020-012226" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26903", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012226", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-334", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "NVD", "id": "CVE-2020-26903" }, { "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "id": "VAR-202010-0569", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:16:49.425000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0043", "trust": 0.8, "url": "https://kb.netgear.com/000062351/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0043" }, { "title": "Multiple NETGEAR Repair measures for device security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131122" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "NVD", "id": "CVE-2020-26903" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062351/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0043" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26903" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "NVD", "id": "CVE-2020-26903" }, { "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "db": "NVD", "id": "CVE-2020-26903" }, { "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "date": "2020-10-09T07:15:15.807000", "db": "NVD", "id": "CVE-2020-26903" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:46:00", "db": "JVNDB", "id": "JVNDB-2020-012226" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26903" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-334" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-334" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials on devices Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012226" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-334" } ], "trust": 0.6 } }
var-202112-2406
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2406", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45542" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45542" } ] }, "cve": "CVE-2021-45542", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CVE-2021-45542", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "id": "CVE-2021-45542", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45542", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2360", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45542", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45542" }, { "db": "CNNVD", "id": "CNNVD-202112-2360" }, { "db": "NVD", "id": "CVE-2021-45542" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45542" }, { "db": "VULMON", "id": "CVE-2021-45542" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45542", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2360", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45542", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45542" }, { "db": "CNNVD", "id": "CNNVD-202112-2360" }, { "db": "NVD", "id": "CVE-2021-45542" } ] }, "id": "VAR-202112-2406", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.2019032275 }, "last_update_date": "2022-05-04T10:07:01.008000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177070" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2360" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45542" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064143/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0540" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45542" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45542" }, { "db": "CNNVD", "id": "CNNVD-202112-2360" }, { "db": "NVD", "id": "CVE-2021-45542" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45542" }, { "db": "CNNVD", "id": "CNNVD-202112-2360" }, { "db": "NVD", "id": "CVE-2021-45542" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45542" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2360" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45542" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45542" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2360" }, { "date": "2022-01-04T22:09:00", "db": "NVD", "id": "CVE-2021-45542" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2360" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2360" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2360" } ], "trust": 0.6 } }
var-202112-2369
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2369", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "NVD", "id": "CVE-2021-45579" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45579" } ] }, "cve": "CVE-2021-45579", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45579", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45579", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45579", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45579", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2373", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45579", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45579" }, { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "NVD", "id": "CVE-2021-45579" }, { "db": "NVD", "id": "CVE-2021-45579" }, { "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45579" }, { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "VULMON", "id": "CVE-2021-45579" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45579", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016889", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2373", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45579", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45579" }, { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "NVD", "id": "CVE-2021-45579" }, { "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "id": "VAR-202112-2369", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:16:02.163000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0087", "trust": 0.8, "url": "https://kb.netgear.com/000064101/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0087" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177080" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "NVD", "id": "CVE-2021-45579" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064101/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0087" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45579" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45579" }, { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "NVD", "id": "CVE-2021-45579" }, { "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45579" }, { "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "db": "NVD", "id": "CVE-2021-45579" }, { "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45579" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "date": "2021-12-26T01:15:16.747000", "db": "NVD", "id": "CVE-2021-45579" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45579" }, { "date": "2022-12-26T06:09:00", "db": "JVNDB", "id": "JVNDB-2021-016889" }, { "date": "2022-01-04T20:40:17.043000", "db": "NVD", "id": "CVE-2021-45579" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2373" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2373" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016889" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2373" } ], "trust": 0.6 } }
var-202112-2335
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7000v2 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX35v2 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and XR1000 prior to 1.0.0.58
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2335", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax45", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax15", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "NVD", "id": "CVE-2021-45614" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45614" } ] }, "cve": "CVE-2021-45614", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45614", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45614", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45614", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45614", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2414", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "NVD", "id": "CVE-2021-45614" }, { "db": "NVD", "id": "CVE-2021-45614" }, { "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D7000v2 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX35v2 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and XR1000 prior to 1.0.0.58", "sources": [ { "db": "NVD", "id": "CVE-2021-45614" }, { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "VULMON", "id": "CVE-2021-45614" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45614", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017550", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2414", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45614", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45614" }, { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "NVD", "id": "CVE-2021-45614" }, { "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "id": "VAR-202112-2335", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35409547 }, "last_update_date": "2023-12-18T13:27:28.896000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0520", "trust": 0.8, "url": "https://kb.netgear.com/000064141/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0520" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176393" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "NVD", "id": "CVE-2021-45614" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064141/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0520" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45614" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45614" }, { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "NVD", "id": "CVE-2021-45614" }, { "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45614" }, { "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "db": "NVD", "id": "CVE-2021-45614" }, { "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45614" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "date": "2021-12-26T01:15:18.427000", "db": "NVD", "id": "CVE-2021-45614" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45614" }, { "date": "2023-01-25T05:10:00", "db": "JVNDB", "id": "JVNDB-2021-017550" }, { "date": "2022-01-10T16:16:06.890000", "db": "NVD", "id": "CVE-2021-45614" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2414" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2414" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017550" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2414" } ], "trust": 0.6 } }
var-202112-2379
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2379", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "NVD", "id": "CVE-2021-45569" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45569" } ] }, "cve": "CVE-2021-45569", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45569", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45569", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45569", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45569", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2300", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45569", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45569" }, { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "NVD", "id": "CVE-2021-45569" }, { "db": "NVD", "id": "CVE-2021-45569" }, { "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45569" }, { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "VULMON", "id": "CVE-2021-45569" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45569", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016896", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2300", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45569", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45569" }, { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "NVD", "id": "CVE-2021-45569" }, { "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "id": "VAR-202112-2379", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T14:04:08.828000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0077", "trust": 0.8, "url": "https://kb.netgear.com/000064091/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0077" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177062" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "NVD", "id": "CVE-2021-45569" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064091/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0077" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45569" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45569" }, { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "NVD", "id": "CVE-2021-45569" }, { "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45569" }, { "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "db": "NVD", "id": "CVE-2021-45569" }, { "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45569" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "date": "2021-12-26T01:15:16.277000", "db": "NVD", "id": "CVE-2021-45569" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45569" }, { "date": "2022-12-26T07:49:00", "db": "JVNDB", "id": "JVNDB-2021-016896" }, { "date": "2022-01-04T17:12:39.200000", "db": "NVD", "id": "CVE-2021-45569" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2300" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2300" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016896" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2300" } ], "trust": 0.6 } }
var-202112-2279
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.48, EAX80 prior to 1.0.1.64, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, R7000 prior to 1.0.11.116, R7900 prior to 1.0.4.38, R8000 prior to 1.0.4.68, RAX200 prior to 1.0.3.106, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, EX3700 prior to 1.0.0.90, MR60 prior to 1.0.6.110, R7000P prior to 1.3.2.126, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, EX3800 prior to 1.0.0.90, MS60 prior to 1.0.6.110, R6900P prior to 1.3.2.126, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2279", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.126" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax15", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax45", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "NVD", "id": "CVE-2021-45670" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45670" } ] }, "cve": "CVE-2021-45670", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45670", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 0.7, "impactScore": 5.3, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45670", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45670", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45670", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2469", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45670", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45670" }, { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "NVD", "id": "CVE-2021-45670" }, { "db": "NVD", "id": "CVE-2021-45670" }, { "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.48, EAX80 prior to 1.0.1.64, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, R7000 prior to 1.0.11.116, R7900 prior to 1.0.4.38, R8000 prior to 1.0.4.68, RAX200 prior to 1.0.3.106, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, EX3700 prior to 1.0.0.90, MR60 prior to 1.0.6.110, R7000P prior to 1.3.2.126, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, EX3800 prior to 1.0.0.90, MS60 prior to 1.0.6.110, R6900P prior to 1.3.2.126, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45670" }, { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "VULMON", "id": "CVE-2021-45670" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45670", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017168", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2469", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45670", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45670" }, { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "NVD", "id": "CVE-2021-45670" }, { "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "id": "VAR-202112-2279", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3099130713333333 }, "last_update_date": "2023-12-18T11:56:47.677000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0255", "trust": 0.8, "url": "https://kb.netgear.com/000064480/security-advisory-for-stored-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0255" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=175892" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "NVD", "id": "CVE-2021-45670" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064480/security-advisory-for-stored-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0255" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45670" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45670" }, { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "NVD", "id": "CVE-2021-45670" }, { "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45670" }, { "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "db": "NVD", "id": "CVE-2021-45670" }, { "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45670" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "date": "2021-12-26T01:15:21.007000", "db": "NVD", "id": "CVE-2021-45670" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45670" }, { "date": "2023-01-06T05:10:00", "db": "JVNDB", "id": "JVNDB-2021-017168" }, { "date": "2022-01-06T15:22:07.113000", "db": "NVD", "id": "CVE-2021-45670" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2469" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2469" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017168" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2469" } ], "trust": 0.6 } }
var-202006-0928
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0928", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14431" } ] }, "cve": "CVE-2020-14431", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006743", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44776", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006743", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14431", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14431", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006743", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44776", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1245", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNVD", "id": "CNVD-2021-44776" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14431", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006743", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44776", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1245", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "id": "VAR-202006-0928", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" } ] }, "last_update_date": "2023-12-18T13:37:47.354000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0068", "trust": 0.8, "url": "https://kb.netgear.com/000061944/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0068" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44776)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275106" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121993" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14431" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061944/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0068" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14431" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44776" }, { "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "db": "NVD", "id": "CVE-2020-14431" }, { "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44776" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "date": "2020-06-18T17:15:12.250000", "db": "NVD", "id": "CVE-2020-14431" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44776" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006743" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14431" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1245" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1245" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006743" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1245" } ], "trust": 0.6 } }
var-202112-2350
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2350", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45599" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45599" } ] }, "cve": "CVE-2021-45599", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45599", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-45599", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45599", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2394", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45599", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45599" }, { "db": "CNNVD", "id": "CNNVD-202112-2394" }, { "db": "NVD", "id": "CVE-2021-45599" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45599" }, { "db": "VULMON", "id": "CVE-2021-45599" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45599", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2394", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45599", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45599" }, { "db": "CNNVD", "id": "CNNVD-202112-2394" }, { "db": "NVD", "id": "CVE-2021-45599" } ] }, "id": "VAR-202112-2350", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T09:27:27.423000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177114" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2394" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45599" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064145/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0546" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45599" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45599" }, { "db": "CNNVD", "id": "CNNVD-202112-2394" }, { "db": "NVD", "id": "CVE-2021-45599" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45599" }, { "db": "CNNVD", "id": "CNNVD-202112-2394" }, { "db": "NVD", "id": "CVE-2021-45599" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45599" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2394" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45599" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45599" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2394" }, { "date": "2022-01-05T21:39:00", "db": "NVD", "id": "CVE-2021-45599" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2394" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2394" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2394" } ], "trust": 0.6 } }
var-202112-2352
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2352", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45597" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45597" } ] }, "cve": "CVE-2021-45597", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45597", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-45597", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45597", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2392", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45597", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45597" }, { "db": "CNNVD", "id": "CNNVD-202112-2392" }, { "db": "NVD", "id": "CVE-2021-45597" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45597" }, { "db": "VULMON", "id": "CVE-2021-45597" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45597", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2392", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45597", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45597" }, { "db": "CNNVD", "id": "CNNVD-202112-2392" }, { "db": "NVD", "id": "CVE-2021-45597" } ] }, "id": "VAR-202112-2352", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T10:02:58.375000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177111" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2392" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45597" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064142/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0539" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45597" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45597" }, { "db": "CNNVD", "id": "CNNVD-202112-2392" }, { "db": "NVD", "id": "CVE-2021-45597" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45597" }, { "db": "CNNVD", "id": "CNNVD-202112-2392" }, { "db": "NVD", "id": "CVE-2021-45597" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45597" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2392" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45597" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45597" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2392" }, { "date": "2022-01-05T21:14:00", "db": "NVD", "id": "CVE-2021-45597" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2392" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2392" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2392" } ], "trust": 0.6 } }
var-202112-2383
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2383", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "NVD", "id": "CVE-2021-45565" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45565" } ] }, "cve": "CVE-2021-45565", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45565", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45565", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45565", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45565", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2298", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45565", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45565" }, { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "NVD", "id": "CVE-2021-45565" }, { "db": "NVD", "id": "CVE-2021-45565" }, { "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45565" }, { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "VULMON", "id": "CVE-2021-45565" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45565", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016900", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2298", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45565", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45565" }, { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "NVD", "id": "CVE-2021-45565" }, { "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "id": "VAR-202112-2383", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:55:36.478000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0069", "trust": 0.8, "url": "https://kb.netgear.com/000064086/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0069" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177060" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "NVD", "id": "CVE-2021-45565" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064086/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0069" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45565" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45565" }, { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "NVD", "id": "CVE-2021-45565" }, { "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45565" }, { "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "db": "NVD", "id": "CVE-2021-45565" }, { "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45565" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "date": "2021-12-26T01:15:16.083000", "db": "NVD", "id": "CVE-2021-45565" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45565" }, { "date": "2022-12-26T08:08:00", "db": "JVNDB", "id": "JVNDB-2021-016900" }, { "date": "2022-01-04T19:34:00.987000", "db": "NVD", "id": "CVE-2021-45565" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2298" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2298" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016900" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2298" } ], "trust": 0.6 } }
var-202112-2215
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2215", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "NVD", "id": "CVE-2021-45506" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45506" } ] }, "cve": "CVE-2021-45506", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45506", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45506", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45506", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45506", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2324", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45506", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45506" }, { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "NVD", "id": "CVE-2021-45506" }, { "db": "NVD", "id": "CVE-2021-45506" }, { "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45506" }, { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "VULMON", "id": "CVE-2021-45506" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45506", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017144", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2324", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45506", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45506" }, { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "NVD", "id": "CVE-2021-45506" }, { "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "id": "VAR-202112-2215", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:55:39.824000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0483", "trust": 0.8, "url": "https://kb.netgear.com/000064130/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0483" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176058" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "NVD", "id": "CVE-2021-45506" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064130/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0483" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45506" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45506" }, { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "NVD", "id": "CVE-2021-45506" }, { "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45506" }, { "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "db": "NVD", "id": "CVE-2021-45506" }, { "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45506" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "date": "2021-12-26T01:15:13.183000", "db": "NVD", "id": "CVE-2021-45506" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45506" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017144" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45506" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2324" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2324" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017144" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2324" } ], "trust": 0.6 } }
var-202012-1195
Vulnerability from variot
Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects CBR40 before 2.5.0.10, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100 before 1.0.2.28, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150 before 1.0.0.46, EX6200 before 1.0.3.94, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6250 before 1.0.4.42, R6300v2 before 1.0.4.42, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v3 before 1.0.4.98, R6700 before 1.0.2.16, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.32, RAX50 before 1.0.2.32, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V-200 before 1.0.0.46, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3500RP before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, WNR3500Lv2 before 1.2.0.62, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1195", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "wnr3500lv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.62" }, { "model": "r8300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.134" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.84" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.62" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.42" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.60" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.32" }, { "model": "rbs40v-200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "wnr1000v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.78" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.4" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex6000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "r8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.134" }, { "model": "r6300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.42" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.54" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.106" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.58" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.56" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.94" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.102" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "wnr2000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.12" }, { "model": "rx45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.32" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "ex6150", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "ex6920", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.54" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "wndr3400v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.32" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "ex6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.28" }, { "model": "ex6200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.94" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.90" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "dgn2200v4", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.114" }, { "model": "ex3920", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.84" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.84" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "wn3500rp", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "wn2500rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.48" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6220", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex3700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dc112a", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "dgn2200v4", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "NVD", "id": "CVE-2020-35796" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dgn2200v4_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.114", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dgn2200v4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3920_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3920:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6920_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6920:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rx45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rx45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wn2500rpv2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wn2500rpv2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wn3500rp_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wn3500rp:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wndr3400v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wndr3400v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr1000v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr1000v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr2000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr2000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr3500lv2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr3500lv2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-35796" } ] }, "cve": "CVE-2020-35796", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-35796", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-35796", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-35796", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2020-35796", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202012-1747", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "NVD", "id": "CVE-2020-35796" }, { "db": "NVD", "id": "CVE-2020-35796" }, { "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects CBR40 before 2.5.0.10, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100 before 1.0.2.28, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150 before 1.0.0.46, EX6200 before 1.0.3.94, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6250 before 1.0.4.42, R6300v2 before 1.0.4.42, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v3 before 1.0.4.98, R6700 before 1.0.2.16, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.32, RAX50 before 1.0.2.32, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V-200 before 1.0.0.46, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3500RP before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, WNR3500Lv2 before 1.2.0.62, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-35796" }, { "db": "JVNDB", "id": "JVNDB-2020-015040" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35796", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-015040", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1747", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "NVD", "id": "CVE-2020-35796" }, { "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "id": "VAR-202012-1195", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.4330196662222223 }, "last_update_date": "2023-12-18T13:42:43.324000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Range\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0201", "trust": 0.8, "url": "https://kb.netgear.com/000062717/security-advisory-for-pre-authentication-buffer-overflow-on-some-routers-range-extenders-and-wifi-systems-psv-2020-0201" }, { "title": "Certain NETGEAR devices Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138126" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "NVD", "id": "CVE-2020-35796" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062717/security-advisory-for-pre-authentication-buffer-overflow-on-some-routers-range-extenders-and-wifi-systems-psv-2020-0201" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35796" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "NVD", "id": "CVE-2020-35796" }, { "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "db": "NVD", "id": "CVE-2020-35796" }, { "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "date": "2020-12-30T00:15:14.160000", "db": "NVD", "id": "CVE-2020-35796" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-08T08:43:00", "db": "JVNDB", "id": "JVNDB-2020-015040" }, { "date": "2021-01-04T14:42:20.860000", "db": "NVD", "id": "CVE-2020-35796" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1747" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1747" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015040" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1747" } ], "trust": 0.6 } }
var-202010-0565
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0565", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "NVD", "id": "CVE-2020-26899" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26899" } ] }, "cve": "CVE-2020-26899", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26899", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26899", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26899", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-26899", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-329", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "NVD", "id": "CVE-2020-26899" }, { "db": "NVD", "id": "CVE-2020-26899" }, { "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11", "sources": [ { "db": "NVD", "id": "CVE-2020-26899" }, { "db": "JVNDB", "id": "JVNDB-2020-012224" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26899", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012224", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-329", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "NVD", "id": "CVE-2020-26899" }, { "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "id": "VAR-202010-0565", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:12:49.373000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0030", "trust": 0.8, "url": "https://kb.netgear.com/000062355/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0030" }, { "title": "Multiple NETGEAR Repair measures for device information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131118" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "NVD", "id": "CVE-2020-26899" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062355/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0030" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26899" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "NVD", "id": "CVE-2020-26899" }, { "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "db": "NVD", "id": "CVE-2020-26899" }, { "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "date": "2020-10-09T07:15:13.870000", "db": "NVD", "id": "CVE-2020-26899" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:46:00", "db": "JVNDB", "id": "JVNDB-2020-012224" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26899" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-329" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-329" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Information leakage vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012224" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-329" } ], "trust": 0.6 } }
var-202112-2284
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects EAX20 prior to 1.0.0.36, EAX80 prior to 1.0.1.62, EX3700 prior to 1.0.0.90, EX3800 prior to 1.0.0.90, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, RBW30 prior to 2.6.1.4, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, and RBS40V prior to 2.6.1.4
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2284", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6130", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex3700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "NVD", "id": "CVE-2021-45665" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45665" } ] }, "cve": "CVE-2021-45665", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45665", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 0.7, "impactScore": 5.3, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45665", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45665", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45665", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2461", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45665", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45665" }, { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "NVD", "id": "CVE-2021-45665" }, { "db": "NVD", "id": "CVE-2021-45665" }, { "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects EAX20 prior to 1.0.0.36, EAX80 prior to 1.0.1.62, EX3700 prior to 1.0.0.90, EX3800 prior to 1.0.0.90, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, RBW30 prior to 2.6.1.4, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, and RBS40V prior to 2.6.1.4", "sources": [ { "db": "NVD", "id": "CVE-2021-45665" }, { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "VULMON", "id": "CVE-2021-45665" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45665", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017029", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2461", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45665", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45665" }, { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "NVD", "id": "CVE-2021-45665" }, { "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "id": "VAR-202112-2284", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.282379965 }, "last_update_date": "2023-12-18T13:01:00.172000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Extenders\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0247", "trust": 0.8, "url": "https://kb.netgear.com/000064120/security-advisory-for-stored-cross-site-scripting-on-some-extenders-and-wifi-systems-psv-2020-0247" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176223" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "NVD", "id": "CVE-2021-45665" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064120/security-advisory-for-stored-cross-site-scripting-on-some-extenders-and-wifi-systems-psv-2020-0247" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45665" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45665" }, { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "NVD", "id": "CVE-2021-45665" }, { "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45665" }, { "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "db": "NVD", "id": "CVE-2021-45665" }, { "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45665" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "date": "2021-12-26T01:15:20.780000", "db": "NVD", "id": "CVE-2021-45665" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45665" }, { "date": "2022-12-28T00:40:00", "db": "JVNDB", "id": "JVNDB-2021-017029" }, { "date": "2022-01-05T21:11:54.300000", "db": "NVD", "id": "CVE-2021-45665" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2461" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2461" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017029" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2461" } ], "trust": 0.6 } }
var-202112-2336
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, D7000v2 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, MR80 prior to 1.1.2.20, MS80 prior to 1.1.2.20, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX35v2 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and XR1000 prior to 1.0.0.58
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2336", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "mr80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.2.20" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "ms80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.2.20" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax15", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "NVD", "id": "CVE-2021-45613" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45613" } ] }, "cve": "CVE-2021-45613", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45613", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45613", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45613", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45613", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2409", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45613", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45613" }, { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "NVD", "id": "CVE-2021-45613" }, { "db": "NVD", "id": "CVE-2021-45613" }, { "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, D7000v2 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, MR80 prior to 1.1.2.20, MS80 prior to 1.1.2.20, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX35v2 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and XR1000 prior to 1.0.0.58", "sources": [ { "db": "NVD", "id": "CVE-2021-45613" }, { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "VULMON", "id": "CVE-2021-45613" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45613", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017549", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2409", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45613", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45613" }, { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "NVD", "id": "CVE-2021-45613" }, { "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "id": "VAR-202112-2336", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35409547 }, "last_update_date": "2023-12-18T13:12:15.390000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0508", "trust": 0.8, "url": "https://kb.netgear.com/000064138/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0508" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176388" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "NVD", "id": "CVE-2021-45613" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064138/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0508" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45613" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45613" }, { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "NVD", "id": "CVE-2021-45613" }, { "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45613" }, { "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "db": "NVD", "id": "CVE-2021-45613" }, { "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45613" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "date": "2021-12-26T01:15:18.383000", "db": "NVD", "id": "CVE-2021-45613" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-07T00:00:00", "db": "VULMON", "id": "CVE-2021-45613" }, { "date": "2023-01-25T05:10:00", "db": "JVNDB", "id": "JVNDB-2021-017549" }, { "date": "2022-01-07T19:55:56.960000", "db": "NVD", "id": "CVE-2021-45613" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2409" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2409" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017549" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2409" } ], "trust": 0.6 } }
var-202108-1622
Vulnerability from variot
Certain NETGEAR devices are affected by lack of access control at the function level. This affects D6220 before 1.0.0.48, D6400 before 1.0.0.82, D7000v2 before 1.0.0.52, D7800 before 1.0.1.44, D8500 before 1.0.3.43, DC112A before 1.0.0.40, DGN2200v4 before 1.0.0.108, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, R6020 before 1.0.0.34, R6080 before 1.0.0.34, R6120 before 1.0.0.44, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6250 before 1.0.4.34, R6260 before 1.1.0.40, R6850 before 1.1.0.40, R6350 before 1.1.0.40, R6400v2 before 1.0.2.62, R6700v3 before 1.0.2.62, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7000 before 1.0.9.34, R6900P before 1.3.1.44, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7200 before 1.2.0.48, R7350 before 1.2.0.48, R7400 before 1.2.0.48, R7450 before 1.2.0.36, AC2100 before 1.2.0.36, AC2400 before 1.2.0.36, AC2600 before 1.2.0.36, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, R7900 before 1.0.3.8, R7960P before 1.4.1.44, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RAX120 before 1.0.0.74, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, WNR3500Lv2 before 1.2.0.56, XR450 before 2.3.2.32, and XR500 before 2.3.2.32. This affects D6220 prior to 1.0.0.48, D6400 prior to 1.0.0.82, D7000v2 prior to 1.0.0.52, D7800 prior to 1.0.1.44, D8500 prior to 1.0.3.43, DC112A prior to 1.0.0.40, DGN2200v4 prior to 1.0.0.108, RBK50 prior to 2.3.0.32, RBR50 prior to 2.3.0.32, RBS50 prior to 2.3.0.32, RBK20 prior to 2.3.0.28, RBR20 prior to 2.3.0.28, RBS20 prior to 2.3.0.28, RBK40 prior to 2.3.0.28, RBR40 prior to 2.3.0.28, RBS40 prior to 2.3.0.28, R6020 prior to 1.0.0.34, R6080 prior to 1.0.0.34, R6120 prior to 1.0.0.44, R6220 prior to 1.1.0.80, R6230 prior to 1.1.0.80, R6250 prior to 1.0.4.34, R6260 prior to 1.1.0.40, R6850 prior to 1.1.0.40, R6350 prior to 1.1.0.40, R6400v2 prior to 1.0.2.62, R6700v3 prior to 1.0.2.62, R6700v2 prior to 1.2.0.36, R6800 prior to 1.2.0.36, R6900v2 prior to 1.2.0.36, R7000 prior to 1.0.9.34, R6900P prior to 1.3.1.44, R7000P prior to 1.3.1.44, R7100LG prior to 1.0.0.48, R7200 prior to 1.2.0.48, R7350 prior to 1.2.0.48, R7400 prior to 1.2.0.48, R7450 prior to 1.2.0.36, AC2100 prior to 1.2.0.36, AC2400 prior to 1.2.0.36, AC2600 prior to 1.2.0.36, R7500v2 prior to 1.0.3.38, R7800 prior to 1.0.2.58, R7900 prior to 1.0.3.8, R7960P prior to 1.4.1.44, R8000 prior to 1.0.4.28, R7900P prior to 1.4.1.30, R8000P prior to 1.4.1.30, R8900 prior to 1.0.4.2, R9000 prior to 1.0.4.2, RAX120 prior to 1.0.0.74, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, WNR3500Lv2 prior to 1.2.0.56, XR450 prior to 2.3.2.32, and XR500 prior to 2.3.2.32
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1622", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "ac2600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.58" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r7200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.48" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.82" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "ac2400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.1.44" }, { "model": "r7450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "r6080", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.34" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "r6850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.40" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r6800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.62" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.80" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.43" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.40" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.28" }, { "model": "r7350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.48" }, { "model": "r6020", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.34" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.80" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.32" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.8" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.9.34" }, { "model": "dgn2200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.108" }, { "model": "r6260", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.40" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.62" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.1.44" }, { "model": "r7400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.48" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "ac2100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.36" }, { "model": "r7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.38" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.2" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.30" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.2" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "wnr3500l", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.56" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.32" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.34" }, { "model": "r6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "d7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.52" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.44" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "r6350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.40" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.30" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.28" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.44" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.0.32" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38516" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.43", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.9.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.8", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.30", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.30", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38516" } ] }, "cve": "CVE-2021-38516", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CVE-2021-38516", "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "HIGH", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-38516", "trust": 1.0, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-38516", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202108-961", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-38516", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38516" }, { "db": "NVD", "id": "CVE-2021-38516" }, { "db": "NVD", "id": "CVE-2021-38516" }, { "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects D6220 before 1.0.0.48, D6400 before 1.0.0.82, D7000v2 before 1.0.0.52, D7800 before 1.0.1.44, D8500 before 1.0.3.43, DC112A before 1.0.0.40, DGN2200v4 before 1.0.0.108, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, R6020 before 1.0.0.34, R6080 before 1.0.0.34, R6120 before 1.0.0.44, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6250 before 1.0.4.34, R6260 before 1.1.0.40, R6850 before 1.1.0.40, R6350 before 1.1.0.40, R6400v2 before 1.0.2.62, R6700v3 before 1.0.2.62, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7000 before 1.0.9.34, R6900P before 1.3.1.44, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7200 before 1.2.0.48, R7350 before 1.2.0.48, R7400 before 1.2.0.48, R7450 before 1.2.0.36, AC2100 before 1.2.0.36, AC2400 before 1.2.0.36, AC2600 before 1.2.0.36, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, R7900 before 1.0.3.8, R7960P before 1.4.1.44, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RAX120 before 1.0.0.74, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, WNR3500Lv2 before 1.2.0.56, XR450 before 2.3.2.32, and XR500 before 2.3.2.32. This affects D6220 prior to 1.0.0.48, D6400 prior to 1.0.0.82, D7000v2 prior to 1.0.0.52, D7800 prior to 1.0.1.44, D8500 prior to 1.0.3.43, DC112A prior to 1.0.0.40, DGN2200v4 prior to 1.0.0.108, RBK50 prior to 2.3.0.32, RBR50 prior to 2.3.0.32, RBS50 prior to 2.3.0.32, RBK20 prior to 2.3.0.28, RBR20 prior to 2.3.0.28, RBS20 prior to 2.3.0.28, RBK40 prior to 2.3.0.28, RBR40 prior to 2.3.0.28, RBS40 prior to 2.3.0.28, R6020 prior to 1.0.0.34, R6080 prior to 1.0.0.34, R6120 prior to 1.0.0.44, R6220 prior to 1.1.0.80, R6230 prior to 1.1.0.80, R6250 prior to 1.0.4.34, R6260 prior to 1.1.0.40, R6850 prior to 1.1.0.40, R6350 prior to 1.1.0.40, R6400v2 prior to 1.0.2.62, R6700v3 prior to 1.0.2.62, R6700v2 prior to 1.2.0.36, R6800 prior to 1.2.0.36, R6900v2 prior to 1.2.0.36, R7000 prior to 1.0.9.34, R6900P prior to 1.3.1.44, R7000P prior to 1.3.1.44, R7100LG prior to 1.0.0.48, R7200 prior to 1.2.0.48, R7350 prior to 1.2.0.48, R7400 prior to 1.2.0.48, R7450 prior to 1.2.0.36, AC2100 prior to 1.2.0.36, AC2400 prior to 1.2.0.36, AC2600 prior to 1.2.0.36, R7500v2 prior to 1.0.3.38, R7800 prior to 1.0.2.58, R7900 prior to 1.0.3.8, R7960P prior to 1.4.1.44, R8000 prior to 1.0.4.28, R7900P prior to 1.4.1.30, R8000P prior to 1.4.1.30, R8900 prior to 1.0.4.2, R9000 prior to 1.0.4.2, RAX120 prior to 1.0.0.74, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, WNR3500Lv2 prior to 1.2.0.56, XR450 prior to 2.3.2.32, and XR500 prior to 2.3.2.32", "sources": [ { "db": "NVD", "id": "CVE-2021-38516" }, { "db": "VULMON", "id": "CVE-2021-38516" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-38516", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202108-961", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-38516", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38516" }, { "db": "NVD", "id": "CVE-2021-38516" }, { "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "id": "VAR-202108-1622", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.33163068799999995 }, "last_update_date": "2023-12-18T13:51:26.066000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Multiple Netgear Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159355" }, { "title": "CVE-2021-38516", "trust": 0.1, "url": "https://github.com/alaial90/cve-2021-38516 " } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38516" }, { "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-Other", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38516" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063780/security-advisory-for-missing-function-level-access-control-on-some-routers-gateways-and-wifi-systems-psv-2020-0273" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38516" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/863.html" }, { "trust": 0.1, "url": "https://github.com/alaial90/cve-2021-38516" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38516" }, { "db": "NVD", "id": "CVE-2021-38516" }, { "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-38516" }, { "db": "NVD", "id": "CVE-2021-38516" }, { "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-11T00:00:00", "db": "VULMON", "id": "CVE-2021-38516" }, { "date": "2021-08-11T00:15:25.580000", "db": "NVD", "id": "CVE-2021-38516" }, { "date": "2021-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-19T00:00:00", "db": "VULMON", "id": "CVE-2021-38516" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-38516" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-961" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-961" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Multiple Netgear Product security vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-961" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-961" } ], "trust": 0.6 } }
var-202112-2212
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2212", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "NVD", "id": "CVE-2021-45509" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45509" } ] }, "cve": "CVE-2021-45509", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45509", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45509", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45509", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45509", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2320", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45509", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45509" }, { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "NVD", "id": "CVE-2021-45509" }, { "db": "NVD", "id": "CVE-2021-45509" }, { "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45509" }, { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "VULMON", "id": "CVE-2021-45509" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45509", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017147", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2320", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45509", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45509" }, { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "NVD", "id": "CVE-2021-45509" }, { "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "id": "VAR-202112-2212", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:46:52.366000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0564", "trust": 0.8, "url": "https://kb.netgear.com/000064148/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0564" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176042" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "NVD", "id": "CVE-2021-45509" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064148/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0564" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45509" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45509" }, { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "NVD", "id": "CVE-2021-45509" }, { "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45509" }, { "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "db": "NVD", "id": "CVE-2021-45509" }, { "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45509" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "date": "2021-12-26T01:15:13.333000", "db": "NVD", "id": "CVE-2021-45509" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45509" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017147" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45509" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2320" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2320" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017147" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2320" } ], "trust": 0.6 } }
var-202112-2382
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2382", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "NVD", "id": "CVE-2021-45566" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45566" } ] }, "cve": "CVE-2021-45566", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45566", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45566", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45566", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45566", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2294", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45566", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45566" }, { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "NVD", "id": "CVE-2021-45566" }, { "db": "NVD", "id": "CVE-2021-45566" }, { "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45566" }, { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "VULMON", "id": "CVE-2021-45566" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45566", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016901", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2294", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45566", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45566" }, { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "NVD", "id": "CVE-2021-45566" }, { "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "id": "VAR-202112-2382", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:32:23.541000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0070", "trust": 0.8, "url": "https://kb.netgear.com/000064087/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0070" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177056" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "NVD", "id": "CVE-2021-45566" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064087/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0070" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45566" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45566" }, { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "NVD", "id": "CVE-2021-45566" }, { "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45566" }, { "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "db": "NVD", "id": "CVE-2021-45566" }, { "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45566" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "date": "2021-12-26T01:15:16.130000", "db": "NVD", "id": "CVE-2021-45566" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45566" }, { "date": "2022-12-26T08:10:00", "db": "JVNDB", "id": "JVNDB-2021-016901" }, { "date": "2022-01-04T19:32:07.923000", "db": "NVD", "id": "CVE-2021-45566" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2294" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2294" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016901" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2294" } ], "trust": 0.6 } }
var-202103-1281
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1281", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29078" } ] }, "cve": "CVE-2021-29078", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29078", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004583", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29078", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29078", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1345", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29078", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "VULMON", "id": "CVE-2021-29078" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29078", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004583", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1345", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29078", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "id": "VAR-202103-1281", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35096342999999997 }, "last_update_date": "2023-12-18T13:37:28.476000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0511", "trust": 0.8, "url": "https://kb.netgear.com/000063009/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0511" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145161" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063009/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0511" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29078" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29078" }, { "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "db": "NVD", "id": "CVE-2021-29078" }, { "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29078" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "date": "2021-03-23T07:15:14.077000", "db": "NVD", "id": "CVE-2021-29078" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29078" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004583" }, { "date": "2021-03-24T19:35:13.467000", "db": "NVD", "id": "CVE-2021-29078" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1345" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1345" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004583" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1345" } ], "trust": 0.6 } }
var-202103-1271
Vulnerability from variot
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects R6700v3 prior to 1.0.4.98, R6400v2 prior to 1.0.4.98, R7000 prior to 1.0.11.106, R6900P prior to 1.3.2.124, R7000P prior to 1.3.2.124, R7900 prior to 1.0.4.26, R7850 prior to 1.0.5.60, R8000 prior to 1.0.4.58, RS400 prior to 1.5.0.48, R6400 prior to 1.0.1.62, R6700 prior to 1.0.2.16, R6900 prior to 1.0.2.16, MK60 prior to 1.0.5.102, MR60 prior to 1.0.5.102, MS60 prior to 1.0.5.102, CBR40 prior to 2.5.0.10, R8000P prior to 1.4.1.62, R7960P prior to 1.4.1.62, R7900P prior to 1.4.1.62, RAX15 prior to 1.0.1.64, RAX20 prior to 1.0.1.64, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, RAX200 prior to 1.0.2.102, RAX45 prior to 1.0.2.64, RAX50 prior to 1.0.2.64, EX7500 prior to 1.0.0.68, EAX80 prior to 1.0.1.62, EAX20 prior to 1.0.0.36, RBK752 prior to 3.2.16.6, RBK753 prior to 3.2.16.6, RBK753S prior to 3.2.16.6, RBK754 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBK853 prior to 3.2.16.6, RBK854 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBR840 prior to 3.2.16.6, RBS840 prior to 3.2.16.6, R6120 prior to 1.0.0.70, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6260 prior to 1.1.0.76, R6850 prior to 1.1.0.76, R6350 prior to 1.1.0.76, R6330 prior to 1.1.0.76, D7800 prior to 1.0.1.58, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK40 prior to 2.6.1.36, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK23 prior to 2.6.1.36, RBR20 prior to 2.6.1.38, RBS20 prior to 2.6.1.38, RBK12 prior to 2.6.1.44, RBK13 prior to 2.6.1.44, RBK14 prior to 2.6.1.44, RBK15 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, R6800 prior to 1.2.0.72, R6900v2 prior to 1.2.0.72, R6700v2 prior to 1.2.0.72, R7200 prior to 1.2.0.72, R7350 prior to 1.2.0.72, R7400 prior to 1.2.0.72, R7450 prior to 1.2.0.72, AC2100 prior to 1.2.0.72, AC2400 prior to 1.2.0.72, AC2600 prior to 1.2.0.72, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.24, R9000 prior to 1.0.5.24, RAX120 prior to 1.0.1.136, XR450 prior to 2.3.2.66, XR500 prior to 2.3.2.66, XR700 prior to 1.0.1.34, and XR300 prior to 1.0.3.50
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1271", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "r7400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.60" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.74" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.106" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.136" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "r6260", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.102" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "ac2400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbr10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "r7450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "r6800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.48" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "r7350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk23", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "mk60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "r6330", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "r6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "ac2100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.58" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "rbk14", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.58" }, { "model": "rbs10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ac2600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r7200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "r6350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk13", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbk12", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk60:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6120:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6220:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6230:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6260:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6850:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6350:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6330:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7800:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk50:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr50:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk40:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr40:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk23_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk23:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr20:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs20:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk12:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk13_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk13:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk14_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk14:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk15:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr10:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs10:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6800:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7200:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7350:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7400:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7450:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2100:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2400:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2600:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8900:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r9000:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax120:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr450:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr500:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr700:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29068" } ] }, "cve": "CVE-2021-29068", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29068", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.1, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29068", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29068", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29068", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1360", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29068", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects R6700v3 prior to 1.0.4.98, R6400v2 prior to 1.0.4.98, R7000 prior to 1.0.11.106, R6900P prior to 1.3.2.124, R7000P prior to 1.3.2.124, R7900 prior to 1.0.4.26, R7850 prior to 1.0.5.60, R8000 prior to 1.0.4.58, RS400 prior to 1.5.0.48, R6400 prior to 1.0.1.62, R6700 prior to 1.0.2.16, R6900 prior to 1.0.2.16, MK60 prior to 1.0.5.102, MR60 prior to 1.0.5.102, MS60 prior to 1.0.5.102, CBR40 prior to 2.5.0.10, R8000P prior to 1.4.1.62, R7960P prior to 1.4.1.62, R7900P prior to 1.4.1.62, RAX15 prior to 1.0.1.64, RAX20 prior to 1.0.1.64, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, RAX200 prior to 1.0.2.102, RAX45 prior to 1.0.2.64, RAX50 prior to 1.0.2.64, EX7500 prior to 1.0.0.68, EAX80 prior to 1.0.1.62, EAX20 prior to 1.0.0.36, RBK752 prior to 3.2.16.6, RBK753 prior to 3.2.16.6, RBK753S prior to 3.2.16.6, RBK754 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBK853 prior to 3.2.16.6, RBK854 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBR840 prior to 3.2.16.6, RBS840 prior to 3.2.16.6, R6120 prior to 1.0.0.70, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6260 prior to 1.1.0.76, R6850 prior to 1.1.0.76, R6350 prior to 1.1.0.76, R6330 prior to 1.1.0.76, D7800 prior to 1.0.1.58, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK40 prior to 2.6.1.36, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK23 prior to 2.6.1.36, RBR20 prior to 2.6.1.38, RBS20 prior to 2.6.1.38, RBK12 prior to 2.6.1.44, RBK13 prior to 2.6.1.44, RBK14 prior to 2.6.1.44, RBK15 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, R6800 prior to 1.2.0.72, R6900v2 prior to 1.2.0.72, R6700v2 prior to 1.2.0.72, R7200 prior to 1.2.0.72, R7350 prior to 1.2.0.72, R7400 prior to 1.2.0.72, R7450 prior to 1.2.0.72, AC2100 prior to 1.2.0.72, AC2400 prior to 1.2.0.72, AC2600 prior to 1.2.0.72, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.24, R9000 prior to 1.0.5.24, RAX120 prior to 1.0.1.136, XR450 prior to 2.3.2.66, XR500 prior to 2.3.2.66, XR700 prior to 1.0.1.34, and XR300 prior to 1.0.3.50", "sources": [ { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "VULMON", "id": "CVE-2021-29068" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29068", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-005326", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1360", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29068", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "id": "VAR-202103-1271", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.32033295292682923 }, "last_update_date": "2023-12-18T13:51:35.075000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems\u00a0,\u00a0PSV-2020-0155", "trust": 0.8, "url": "https://kb.netgear.com/000063021/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-extenders-and-wifi-systems-psv-2020-0155" }, { "title": "Netgear NETGEAR Buffer error vulnerability fix", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145681" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063021/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-extenders-and-wifi-systems-psv-2020-0155" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29068" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/120.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29068" }, { "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "db": "NVD", "id": "CVE-2021-29068" }, { "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29068" }, { "date": "2021-12-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "date": "2021-03-23T07:15:13.297000", "db": "NVD", "id": "CVE-2021-29068" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-27T00:00:00", "db": "VULMON", "id": "CVE-2021-29068" }, { "date": "2021-12-13T01:53:00", "db": "JVNDB", "id": "JVNDB-2021-005326" }, { "date": "2021-03-27T01:23:02.573000", "db": "NVD", "id": "CVE-2021-29068" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1360" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1360" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-005326" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1360" } ], "trust": 0.6 } }
var-202112-2401
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2401", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "NVD", "id": "CVE-2021-45547" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45547" } ] }, "cve": "CVE-2021-45547", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45547", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45547", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45547", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45547", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2363", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45547", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45547" }, { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "NVD", "id": "CVE-2021-45547" }, { "db": "NVD", "id": "CVE-2021-45547" }, { "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45547" }, { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "VULMON", "id": "CVE-2021-45547" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45547", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017184", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2363", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45547", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45547" }, { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "NVD", "id": "CVE-2021-45547" }, { "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "id": "VAR-202112-2401", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.268308725 }, "last_update_date": "2023-12-18T13:46:51.863000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0567", "trust": 0.8, "url": "https://kb.netgear.com/000064525/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0567" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176376" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "NVD", "id": "CVE-2021-45547" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064525/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0567" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45547" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45547" }, { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "NVD", "id": "CVE-2021-45547" }, { "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45547" }, { "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "db": "NVD", "id": "CVE-2021-45547" }, { "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45547" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "date": "2021-12-26T01:15:15.227000", "db": "NVD", "id": "CVE-2021-45547" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45547" }, { "date": "2023-01-06T06:53:00", "db": "JVNDB", "id": "JVNDB-2021-017184" }, { "date": "2022-01-06T19:13:20.593000", "db": "NVD", "id": "CVE-2021-45547" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2363" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2363" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017184" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2363" } ], "trust": 0.6 } }
var-202112-2413
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.3.106, RAX80 before 1.0.3.106, RAX75 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX200 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RAX75 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2413", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": null }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "NVD", "id": "CVE-2021-45535" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45535" } ] }, "cve": "CVE-2021-45535", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45535", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45535", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45535", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45535", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2349", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45535", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45535" }, { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "NVD", "id": "CVE-2021-45535" }, { "db": "NVD", "id": "CVE-2021-45535" }, { "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.3.106, RAX80 before 1.0.3.106, RAX75 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX200 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RAX75 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45535" }, { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "VULMON", "id": "CVE-2021-45535" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45535", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016937", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2349", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45535", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45535" }, { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "NVD", "id": "CVE-2021-45535" }, { "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "id": "VAR-202112-2413", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:48:55.604000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0052", "trust": 0.8, "url": "https://kb.netgear.com/000064457/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0052" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177109" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "NVD", "id": "CVE-2021-45535" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064457/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0052" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45535" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45535" }, { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "NVD", "id": "CVE-2021-45535" }, { "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45535" }, { "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "db": "NVD", "id": "CVE-2021-45535" }, { "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45535" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "date": "2021-12-26T01:15:14.647000", "db": "NVD", "id": "CVE-2021-45535" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45535" }, { "date": "2022-12-27T04:40:00", "db": "JVNDB", "id": "JVNDB-2021-016937" }, { "date": "2022-01-04T20:44:31.313000", "db": "NVD", "id": "CVE-2021-45535" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2349" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2349" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016937" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2349" } ], "trust": 0.6 } }
var-202112-2359
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2359", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "NVD", "id": "CVE-2021-45590" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45590" } ] }, "cve": "CVE-2021-45590", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45590", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45590", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45590", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45590", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2384", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45590", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45590" }, { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "NVD", "id": "CVE-2021-45590" }, { "db": "NVD", "id": "CVE-2021-45590" }, { "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45590" }, { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "VULMON", "id": "CVE-2021-45590" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45590", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016971", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2384", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45590", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45590" }, { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "NVD", "id": "CVE-2021-45590" }, { "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "id": "VAR-202112-2359", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:46:51.917000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0098", "trust": 0.8, "url": "https://kb.netgear.com/000064112/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0098" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177099" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "NVD", "id": "CVE-2021-45590" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064112/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0098" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45590" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45590" }, { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "NVD", "id": "CVE-2021-45590" }, { "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45590" }, { "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "db": "NVD", "id": "CVE-2021-45590" }, { "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45590" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "date": "2021-12-26T01:15:17.257000", "db": "NVD", "id": "CVE-2021-45590" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45590" }, { "date": "2022-12-27T05:37:00", "db": "JVNDB", "id": "JVNDB-2021-016971" }, { "date": "2022-01-04T20:26:07.880000", "db": "NVD", "id": "CVE-2021-45590" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2384" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2384" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016971" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2384" } ], "trust": 0.6 } }
var-202112-2378
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2378", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "NVD", "id": "CVE-2021-45570" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45570" } ] }, "cve": "CVE-2021-45570", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45570", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45570", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45570", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45570", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2301", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45570", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45570" }, { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "NVD", "id": "CVE-2021-45570" }, { "db": "NVD", "id": "CVE-2021-45570" }, { "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45570" }, { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "VULMON", "id": "CVE-2021-45570" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45570", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016897", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2301", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45570", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45570" }, { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "NVD", "id": "CVE-2021-45570" }, { "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "id": "VAR-202112-2378", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:12:15.340000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0078", "trust": 0.8, "url": "https://kb.netgear.com/000064092/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0078" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177063" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "NVD", "id": "CVE-2021-45570" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064092/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0078" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45570" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45570" }, { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "NVD", "id": "CVE-2021-45570" }, { "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45570" }, { "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "db": "NVD", "id": "CVE-2021-45570" }, { "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45570" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "date": "2021-12-26T01:15:16.327000", "db": "NVD", "id": "CVE-2021-45570" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45570" }, { "date": "2022-12-26T07:51:00", "db": "JVNDB", "id": "JVNDB-2021-016897" }, { "date": "2022-01-04T19:57:37.717000", "db": "NVD", "id": "CVE-2021-45570" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2301" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2301" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016897" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2301" } ], "trust": 0.6 } }
var-202012-1197
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6900P before 1.3.2.124, R7000 before 1.0.11.100, R7000P before 1.3.2.124, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7960P before 1.4.1.50, R8000 before 1.0.4.52, R7900P before 1.4.1.50, R8000P before 1.4.1.50, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.1.12, RAX45 before 1.0.2.66, RAX50 before 1.0.2.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RS400 before 1.5.0.48, and XR300 before 1.0.3.50. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1197", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.84" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.66" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.100" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.66" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.52" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.60" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.12" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.84" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.74" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.48" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.50" }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700v3", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "NVD", "id": "CVE-2020-35798" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-35798" } ] }, "cve": "CVE-2020-35798", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.2, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-35798", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.3, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.5, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-35798", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-35798", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-35798", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202012-1738", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "NVD", "id": "CVE-2020-35798" }, { "db": "NVD", "id": "CVE-2020-35798" }, { "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6900P before 1.3.2.124, R7000 before 1.0.11.100, R7000P before 1.3.2.124, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7960P before 1.4.1.50, R8000 before 1.0.4.52, R7900P before 1.4.1.50, R8000P before 1.4.1.50, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.1.12, RAX45 before 1.0.2.66, RAX50 before 1.0.2.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RS400 before 1.5.0.48, and XR300 before 1.0.3.50. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-35798" }, { "db": "JVNDB", "id": "JVNDB-2020-015041" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35798", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-015041", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1738", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "NVD", "id": "CVE-2020-35798" }, { "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "id": "VAR-202012-1197", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.349676052 }, "last_update_date": "2023-12-18T12:42:39.364000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0218", "trust": 0.8, "url": "https://kb.netgear.com/000062715/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2019-0218" }, { "title": "Certain NETGEAR devices Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138119" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "NVD", "id": "CVE-2020-35798" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062715/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2019-0218" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35798" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "NVD", "id": "CVE-2020-35798" }, { "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "db": "NVD", "id": "CVE-2020-35798" }, { "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "date": "2020-12-30T00:15:14.267000", "db": "NVD", "id": "CVE-2020-35798" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-08T08:43:00", "db": "JVNDB", "id": "JVNDB-2020-015041" }, { "date": "2021-01-04T15:07:25.333000", "db": "NVD", "id": "CVE-2020-35798" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1738" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1738" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015041" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1738" } ], "trust": 0.6 } }
var-202112-2370
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2370", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "NVD", "id": "CVE-2021-45578" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45578" } ] }, "cve": "CVE-2021-45578", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45578", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45578", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45578", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45578", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2377", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45578", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45578" }, { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "NVD", "id": "CVE-2021-45578" }, { "db": "NVD", "id": "CVE-2021-45578" }, { "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45578" }, { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "VULMON", "id": "CVE-2021-45578" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45578", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016888", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2377", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45578", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45578" }, { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "NVD", "id": "CVE-2021-45578" }, { "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "id": "VAR-202112-2370", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:42:08.938000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0086", "trust": 0.8, "url": "https://kb.netgear.com/000064100/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0086" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177087" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "NVD", "id": "CVE-2021-45578" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064100/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0086" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45578" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45578" }, { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "NVD", "id": "CVE-2021-45578" }, { "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45578" }, { "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "db": "NVD", "id": "CVE-2021-45578" }, { "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45578" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "date": "2021-12-26T01:15:16.697000", "db": "NVD", "id": "CVE-2021-45578" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45578" }, { "date": "2022-12-26T06:07:00", "db": "JVNDB", "id": "JVNDB-2021-016888" }, { "date": "2022-01-04T20:40:54.553000", "db": "NVD", "id": "CVE-2021-45578" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2377" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2377" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016888" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2377" } ], "trust": 0.6 } }
var-202112-2402
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2402", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "NVD", "id": "CVE-2021-45546" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45546" } ] }, "cve": "CVE-2021-45546", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45546", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45546", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45546", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45546", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2361", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45546", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45546" }, { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "NVD", "id": "CVE-2021-45546" }, { "db": "NVD", "id": "CVE-2021-45546" }, { "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45546" }, { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "VULMON", "id": "CVE-2021-45546" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45546", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017188", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2361", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45546", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45546" }, { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "NVD", "id": "CVE-2021-45546" }, { "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "id": "VAR-202112-2402", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.268308725 }, "last_update_date": "2023-12-18T12:55:16.628000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0566", "trust": 0.8, "url": "https://kb.netgear.com/000064524/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0566" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176374" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "NVD", "id": "CVE-2021-45546" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064524/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0566" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45546" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45546" }, { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "NVD", "id": "CVE-2021-45546" }, { "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45546" }, { "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "db": "NVD", "id": "CVE-2021-45546" }, { "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45546" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "date": "2021-12-26T01:15:15.177000", "db": "NVD", "id": "CVE-2021-45546" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45546" }, { "date": "2023-01-06T07:14:00", "db": "JVNDB", "id": "JVNDB-2021-017188" }, { "date": "2022-01-06T18:58:56.933000", "db": "NVD", "id": "CVE-2021-45546" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2361" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2361" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017188" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2361" } ], "trust": 0.6 } }
var-202010-0568
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0568", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "NVD", "id": "CVE-2020-26902" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26902" } ] }, "cve": "CVE-2020-26902", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-26902", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26902", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26902", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26902", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-332", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "NVD", "id": "CVE-2020-26902" }, { "db": "NVD", "id": "CVE-2020-26902" }, { "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26902" }, { "db": "JVNDB", "id": "JVNDB-2020-012228" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26902", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012228", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-332", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "NVD", "id": "CVE-2020-26902" }, { "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "id": "VAR-202010-0568", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:55:52.310000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0041", "trust": 0.8, "url": "https://kb.netgear.com/000062352/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0041" }, { "title": "Multiple NETGEAR Fixes for device command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131121" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "NVD", "id": "CVE-2020-26902" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062352/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0041" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26902" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "NVD", "id": "CVE-2020-26902" }, { "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "db": "NVD", "id": "CVE-2020-26902" }, { "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "date": "2020-10-09T07:15:15.463000", "db": "NVD", "id": "CVE-2020-26902" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:46:00", "db": "JVNDB", "id": "JVNDB-2020-012228" }, { "date": "2020-10-16T19:01:05.520000", "db": "NVD", "id": "CVE-2020-26902" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-332" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-332" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012228" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-332" } ], "trust": 0.6 } }
var-202103-1284
Vulnerability from variot
NETGEAR RBR850 devices before 3.2.10.11 are affected by authentication bypass. NETGEAR RBR850 There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1284", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": "rbr850 firmware 3.2.10.11" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "NVD", "id": "CVE-2021-29065" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29065" } ] }, "cve": "CVE-2021-29065", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "id": "CVE-2021-29065", "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "HIGH", "trust": 1.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-29065", "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004915", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29065", "trust": 1.8, "value": "Critical" }, { "author": "CNNVD", "id": "CNNVD-202103-1363", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29065", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29065" }, { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "CNNVD", "id": "CNNVD-202103-1363" }, { "db": "NVD", "id": "CVE-2021-29065" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR RBR850 devices before 3.2.10.11 are affected by authentication bypass. NETGEAR RBR850 There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2021-29065" }, { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "VULMON", "id": "CVE-2021-29065" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29065", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004915", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1363", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29065", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29065" }, { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "CNNVD", "id": "CNNVD-202103-1363" }, { "db": "NVD", "id": "CVE-2021-29065" } ] }, "id": "VAR-202103-1284", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22886528 }, "last_update_date": "2022-05-04T09:32:29.510000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0RBR850,\u00a0PSV-2020-0029", "trust": 0.8, "url": "https://kb.netgear.com/000063006/security-advisory-for-authentication-bypass-on-rbr850-psv-2020-0029" }, { "title": "Netgear NETGEAR RBR850 Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145684" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "CNNVD", "id": "CNNVD-202103-1363" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-287", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "NVD", "id": "CVE-2021-29065" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063006/security-advisory-for-authentication-bypass-on-rbr850-psv-2020-0029" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29065" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29065" }, { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "CNNVD", "id": "CNNVD-202103-1363" }, { "db": "NVD", "id": "CVE-2021-29065" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29065" }, { "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "db": "CNNVD", "id": "CNNVD-202103-1363" }, { "db": "NVD", "id": "CVE-2021-29065" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29065" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1363" }, { "date": "2021-03-23T07:15:00", "db": "NVD", "id": "CVE-2021-29065" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29065" }, { "date": "2021-12-02T07:59:00", "db": "JVNDB", "id": "JVNDB-2021-004915" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1363" }, { "date": "2021-03-26T14:23:00", "db": "NVD", "id": "CVE-2021-29065" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1363" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "NETGEAR\u00a0RBR850\u00a0 Authentication vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004915" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1363" } ], "trust": 0.6 } }
var-202112-2407
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2407", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax45", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "NVD", "id": "CVE-2021-45541" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45541" } ] }, "cve": "CVE-2021-45541", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45541", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45541", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45541", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45541", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2359", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45541", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45541" }, { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "NVD", "id": "CVE-2021-45541" }, { "db": "NVD", "id": "CVE-2021-45541" }, { "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45541" }, { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "VULMON", "id": "CVE-2021-45541" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45541", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017288", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2359", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45541", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45541" }, { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "NVD", "id": "CVE-2021-45541" }, { "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "id": "VAR-202112-2407", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.30184840857142864 }, "last_update_date": "2023-12-18T13:17:34.388000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0246", "trust": 0.8, "url": "https://kb.netgear.com/000064479/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0246" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176372" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "NVD", "id": "CVE-2021-45541" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064479/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0246" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45541" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45541" }, { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "NVD", "id": "CVE-2021-45541" }, { "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45541" }, { "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "db": "NVD", "id": "CVE-2021-45541" }, { "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45541" }, { "date": "2023-01-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "date": "2021-12-26T01:15:14.937000", "db": "NVD", "id": "CVE-2021-45541" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-07T00:00:00", "db": "VULMON", "id": "CVE-2021-45541" }, { "date": "2023-01-13T05:03:00", "db": "JVNDB", "id": "JVNDB-2021-017288" }, { "date": "2022-01-07T19:18:03.920000", "db": "NVD", "id": "CVE-2021-45541" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2359" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2359" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017288" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2359" } ], "trust": 0.6 } }
var-202112-2205
Vulnerability from variot
Certain NETGEAR devices are affected by denial of service. This affects R6400 before 1.0.1.70, R7000 before 1.0.11.126, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R8000 before 1.0.4.74, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an unspecified vulnerability in the device.Service operation interruption (DoS) It may be in a state. This affects R6400 prior to 1.0.1.70, R7000 prior to 1.0.11.126, R6900P prior to 1.3.3.140, R7000P prior to 1.3.3.140, R8000 prior to 1.0.4.74, RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, and RBS850 prior to 3.2.10.11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2205", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.126" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "r6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "NVD", "id": "CVE-2021-45516" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45516" } ] }, "cve": "CVE-2021-45516", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 2.7, "confidentialityImpact": "NONE", "exploitabilityScore": 5.1, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 2.7, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45516", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 0.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 6.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 1.7, "impactScore": 4.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 4.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45516", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45516", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45516", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2330", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45516", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45516" }, { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "NVD", "id": "CVE-2021-45516" }, { "db": "NVD", "id": "CVE-2021-45516" }, { "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by denial of service. This affects R6400 before 1.0.1.70, R7000 before 1.0.11.126, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R8000 before 1.0.4.74, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an unspecified vulnerability in the device.Service operation interruption (DoS) It may be in a state. This affects R6400 prior to 1.0.1.70, R7000 prior to 1.0.11.126, R6900P prior to 1.3.3.140, R7000P prior to 1.3.3.140, R8000 prior to 1.0.4.74, RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, and RBS850 prior to 3.2.10.11", "sources": [ { "db": "NVD", "id": "CVE-2021-45516" }, { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "VULMON", "id": "CVE-2021-45516" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45516", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017113", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2330", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45516", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45516" }, { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "NVD", "id": "CVE-2021-45516" }, { "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "id": "VAR-202112-2205", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.34795435399999997 }, "last_update_date": "2023-12-18T13:42:20.303000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Denial\u00a0of\u00a0Service\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0115", "trust": 0.8, "url": "https://kb.netgear.com/000064060/security-advisory-for-denial-of-service-on-some-routers-and-wifi-systems-psv-2019-0115" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177076" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "NVD", "id": "CVE-2021-45516" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064060/security-advisory-for-denial-of-service-on-some-routers-and-wifi-systems-psv-2019-0115" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45516" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45516" }, { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "NVD", "id": "CVE-2021-45516" }, { "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45516" }, { "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "db": "NVD", "id": "CVE-2021-45516" }, { "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45516" }, { "date": "2023-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "date": "2021-12-26T01:15:13.670000", "db": "NVD", "id": "CVE-2021-45516" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45516" }, { "date": "2023-01-04T06:53:00", "db": "JVNDB", "id": "JVNDB-2021-017113" }, { "date": "2022-01-05T16:30:05.773000", "db": "NVD", "id": "CVE-2021-45516" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2330" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2330" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017113" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2330" } ], "trust": 0.6 } }
var-202112-2214
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBW30 prior to 2.6.2.2, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and RBS40V prior to 2.6.2.8
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2214", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.8" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "NVD", "id": "CVE-2021-45507" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.8", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45507" } ] }, "cve": "CVE-2021-45507", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45507", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45507", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45507", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45507", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2489", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45507", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45507" }, { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "NVD", "id": "CVE-2021-45507" }, { "db": "NVD", "id": "CVE-2021-45507" }, { "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBW30 prior to 2.6.2.2, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and RBS40V prior to 2.6.2.8", "sources": [ { "db": "NVD", "id": "CVE-2021-45507" }, { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "VULMON", "id": "CVE-2021-45507" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45507", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017145", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2489", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45507", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45507" }, { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "NVD", "id": "CVE-2021-45507" }, { "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "id": "VAR-202112-2214", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.16585818000000002 }, "last_update_date": "2023-12-18T13:32:23.726000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0487", "trust": 0.8, "url": "https://kb.netgear.com/000064131/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0487" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=175929" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "NVD", "id": "CVE-2021-45507" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064131/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0487" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45507" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45507" }, { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "NVD", "id": "CVE-2021-45507" }, { "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45507" }, { "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "db": "NVD", "id": "CVE-2021-45507" }, { "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45507" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "date": "2021-12-26T01:15:13.230000", "db": "NVD", "id": "CVE-2021-45507" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45507" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017145" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45507" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2489" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2489" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017145" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2489" } ], "trust": 0.6 } }
var-202112-2351
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2351", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45598" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45598" } ] }, "cve": "CVE-2021-45598", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45598", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-45598", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45598", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2393", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45598", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45598" }, { "db": "CNNVD", "id": "CNNVD-202112-2393" }, { "db": "NVD", "id": "CVE-2021-45598" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45598" }, { "db": "VULMON", "id": "CVE-2021-45598" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45598", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2393", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45598", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45598" }, { "db": "CNNVD", "id": "CNNVD-202112-2393" }, { "db": "NVD", "id": "CVE-2021-45598" } ] }, "id": "VAR-202112-2351", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T10:25:10.403000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177113" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2393" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45598" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064144/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0544" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45598" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45598" }, { "db": "CNNVD", "id": "CNNVD-202112-2393" }, { "db": "NVD", "id": "CVE-2021-45598" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45598" }, { "db": "CNNVD", "id": "CNNVD-202112-2393" }, { "db": "NVD", "id": "CVE-2021-45598" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45598" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2393" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45598" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45598" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2393" }, { "date": "2022-01-05T21:30:00", "db": "NVD", "id": "CVE-2021-45598" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2393" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2393" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2393" } ], "trust": 0.6 } }
var-202012-1177
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR An unspecified vulnerability exists in the device.Information may be obtained
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1177", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs840v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.14" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "NVD", "id": "CVE-2020-35802" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.14", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-35802" } ] }, "cve": "CVE-2020-35802", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-35802", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-014795", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-35802", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-35802", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202012-1767", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "NVD", "id": "CVE-2020-35802" }, { "db": "NVD", "id": "CVE-2020-35802" }, { "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR An unspecified vulnerability exists in the device.Information may be obtained", "sources": [ { "db": "NVD", "id": "CVE-2020-35802" }, { "db": "JVNDB", "id": "JVNDB-2020-014795" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35802", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-014795", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1767", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "NVD", "id": "CVE-2020-35802" }, { "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "id": "VAR-202012-1177", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.35919061999999996 }, "last_update_date": "2023-12-18T13:27:52.634000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0331", "trust": 0.8, "url": "https://kb.netgear.com/000062720/security-advisory-for-sensitive-information-disclosure-on-some-routers-and-wifi-systems-psv-2020-0331" }, { "title": "Multiple Netgear Product information disclosure vulnerability repair measures", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138274" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "NVD", "id": "CVE-2020-35802" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062720/security-advisory-for-sensitive-information-disclosure-on-some-routers-and-wifi-systems-psv-2020-0331" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35802" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "NVD", "id": "CVE-2020-35802" }, { "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "db": "NVD", "id": "CVE-2020-35802" }, { "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-31T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "date": "2020-12-30T00:15:14.517000", "db": "NVD", "id": "CVE-2020-35802" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-31T05:14:00", "db": "JVNDB", "id": "JVNDB-2020-014795" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-35802" }, { "date": "2021-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1767" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1767" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-014795" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1767" } ], "trust": 0.6 } }
var-202010-0916
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0916", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "NVD", "id": "CVE-2020-26926" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26926" } ] }, "cve": "CVE-2020-26926", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26926", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-012204", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26926", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2020-26926", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-358", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "NVD", "id": "CVE-2020-26926" }, { "db": "NVD", "id": "CVE-2020-26926" }, { "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26926" }, { "db": "JVNDB", "id": "JVNDB-2020-012204" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26926", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012204", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-358", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "NVD", "id": "CVE-2020-26926" }, { "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "id": "VAR-202010-0916", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:51:45.315000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0028", "trust": 0.8, "url": "https://kb.netgear.com/000062326/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0028" }, { "title": "Multiple NETGEAR Product access control error vulnerability fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=129650" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "NVD", "id": "CVE-2020-26926" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062326/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0028" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26926" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "NVD", "id": "CVE-2020-26926" }, { "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "db": "NVD", "id": "CVE-2020-26926" }, { "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "date": "2020-10-09T07:15:18.247000", "db": "NVD", "id": "CVE-2020-26926" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:37:00", "db": "JVNDB", "id": "JVNDB-2020-012204" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26926" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-358" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-358" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Authentication vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012204" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-358" } ], "trust": 0.6 } }
var-202112-2329
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, LAX20 prior to 1.1.6.28, MR60 prior to 1.0.6.116, MR80 prior to 1.1.2.20, MS60 prior to 1.0.6.116, MS80 prior to 1.1.2.20, MK62 prior to 1.0.6.116, MK83 prior to 1.1.2.20, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.106, R6700v3 prior to 1.0.4.106, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2329", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "mr80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.2.20" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.68" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.46" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "mk83", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.2.20" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.126" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "ms80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.2.20" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r6400v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6700v3", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "NVD", "id": "CVE-2021-45620" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk83_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk83:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45620" } ] }, "cve": "CVE-2021-45620", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45620", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45620", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45620", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45620", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2416", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45620", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45620" }, { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "NVD", "id": "CVE-2021-45620" }, { "db": "NVD", "id": "CVE-2021-45620" }, { "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, LAX20 prior to 1.1.6.28, MR60 prior to 1.0.6.116, MR80 prior to 1.1.2.20, MS60 prior to 1.0.6.116, MS80 prior to 1.1.2.20, MK62 prior to 1.0.6.116, MK83 prior to 1.1.2.20, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.106, R6700v3 prior to 1.0.4.106, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68", "sources": [ { "db": "NVD", "id": "CVE-2021-45620" }, { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "VULMON", "id": "CVE-2021-45620" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45620", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017546", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2416", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45620", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45620" }, { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "NVD", "id": "CVE-2021-45620" }, { "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "id": "VAR-202112-2329", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.31989969777777777 }, "last_update_date": "2023-12-18T12:48:55.696000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0509", "trust": 0.8, "url": "https://kb.netgear.com/000064510/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0509" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176395" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "NVD", "id": "CVE-2021-45620" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064510/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0509" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45620" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45620" }, { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "NVD", "id": "CVE-2021-45620" }, { "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45620" }, { "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "db": "NVD", "id": "CVE-2021-45620" }, { "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45620" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "date": "2021-12-26T01:15:18.703000", "db": "NVD", "id": "CVE-2021-45620" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-07T00:00:00", "db": "VULMON", "id": "CVE-2021-45620" }, { "date": "2023-01-25T02:07:00", "db": "JVNDB", "id": "JVNDB-2021-017546" }, { "date": "2022-01-07T19:54:30.073000", "db": "NVD", "id": "CVE-2021-45620" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2416" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2416" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017546" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2416" } ], "trust": 0.6 } }
var-202112-2283
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX80 prior to 1.0.1.64, EX3700 prior to 1.0.0.90, EX3800 prior to 1.0.0.90, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, RBW30 prior to 2.6.1.4, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, and RBS40V prior to 2.6.1.4
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2283", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6130", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex3700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "NVD", "id": "CVE-2021-45666" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45666" } ] }, "cve": "CVE-2021-45666", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45666", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 0.7, "impactScore": 5.3, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45666", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45666", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45666", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2462", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45666", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45666" }, { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "NVD", "id": "CVE-2021-45666" }, { "db": "NVD", "id": "CVE-2021-45666" }, { "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX80 prior to 1.0.1.64, EX3700 prior to 1.0.0.90, EX3800 prior to 1.0.0.90, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, RBW30 prior to 2.6.1.4, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, and RBS40V prior to 2.6.1.4", "sources": [ { "db": "NVD", "id": "CVE-2021-45666" }, { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "VULMON", "id": "CVE-2021-45666" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45666", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017028", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2462", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45666", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45666" }, { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "NVD", "id": "CVE-2021-45666" }, { "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "id": "VAR-202112-2283", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.2810532942857143 }, "last_update_date": "2023-12-18T13:06:53.647000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Extenders\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0254", "trust": 0.8, "url": "https://kb.netgear.com/000064121/security-advisory-for-stored-cross-site-scripting-on-some-extenders-and-wifi-systems-psv-2020-0254" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176224" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "NVD", "id": "CVE-2021-45666" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064121/security-advisory-for-stored-cross-site-scripting-on-some-extenders-and-wifi-systems-psv-2020-0254" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45666" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45666" }, { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "NVD", "id": "CVE-2021-45666" }, { "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45666" }, { "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "db": "NVD", "id": "CVE-2021-45666" }, { "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45666" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "date": "2021-12-26T01:15:20.827000", "db": "NVD", "id": "CVE-2021-45666" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45666" }, { "date": "2022-12-28T00:25:00", "db": "JVNDB", "id": "JVNDB-2021-017028" }, { "date": "2022-01-05T21:19:17.127000", "db": "NVD", "id": "CVE-2021-45666" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2462" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2462" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017028" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2462" } ], "trust": 0.6 } }
var-202112-2411
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX200 prior to 1.0.3.106, RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2411", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": null }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "NVD", "id": "CVE-2021-45537" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45537" } ] }, "cve": "CVE-2021-45537", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45537", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45537", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45537", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45537", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2353", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45537", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45537" }, { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "NVD", "id": "CVE-2021-45537" }, { "db": "NVD", "id": "CVE-2021-45537" }, { "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX200 prior to 1.0.3.106, RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45537" }, { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "VULMON", "id": "CVE-2021-45537" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45537", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016942", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2353", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45537", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45537" }, { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "NVD", "id": "CVE-2021-45537" }, { "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "id": "VAR-202112-2411", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:16:02.118000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0061", "trust": 0.8, "url": "https://kb.netgear.com/000064083/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0061" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177115" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "NVD", "id": "CVE-2021-45537" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064083/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0061" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45537" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45537" }, { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "NVD", "id": "CVE-2021-45537" }, { "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45537" }, { "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "db": "NVD", "id": "CVE-2021-45537" }, { "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45537" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "date": "2021-12-26T01:15:14.747000", "db": "NVD", "id": "CVE-2021-45537" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45537" }, { "date": "2022-12-27T04:48:00", "db": "JVNDB", "id": "JVNDB-2021-016942" }, { "date": "2022-01-04T20:44:15.830000", "db": "NVD", "id": "CVE-2021-45537" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2353" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2353" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016942" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2353" } ], "trust": 0.6 } }
var-202103-1278
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1278", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29075" } ] }, "cve": "CVE-2021-29075", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29075", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004581", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29075", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29075", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1352", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29075", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "VULMON", "id": "CVE-2021-29075" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29075", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004581", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1352", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29075", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "id": "VAR-202103-1278", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.318865984 }, "last_update_date": "2023-12-18T12:49:18.165000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0466", "trust": 0.8, "url": "https://kb.netgear.com/000063010/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-systems-psv-2020-0466" }, { "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=144970" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063010/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-systems-psv-2020-0466" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29075" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29075" }, { "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "db": "NVD", "id": "CVE-2021-29075" }, { "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29075" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "date": "2021-03-23T07:15:13.857000", "db": "NVD", "id": "CVE-2021-29075" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29075" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004581" }, { "date": "2021-03-24T20:18:42.890000", "db": "NVD", "id": "CVE-2021-29075" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1352" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1352" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004581" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1352" } ], "trust": 0.6 } }
var-202112-2361
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2361", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "NVD", "id": "CVE-2021-45588" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45588" } ] }, "cve": "CVE-2021-45588", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45588", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45588", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45588", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45588", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2385", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45588", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45588" }, { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "NVD", "id": "CVE-2021-45588" }, { "db": "NVD", "id": "CVE-2021-45588" }, { "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45588" }, { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "VULMON", "id": "CVE-2021-45588" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45588", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016910", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2385", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45588", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45588" }, { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "NVD", "id": "CVE-2021-45588" }, { "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "id": "VAR-202112-2361", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:32:23.564000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0096", "trust": 0.8, "url": "https://kb.netgear.com/000064110/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0096" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177101" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "NVD", "id": "CVE-2021-45588" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064110/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0096" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45588" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45588" }, { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "NVD", "id": "CVE-2021-45588" }, { "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45588" }, { "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "db": "NVD", "id": "CVE-2021-45588" }, { "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45588" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "date": "2021-12-26T01:15:17.163000", "db": "NVD", "id": "CVE-2021-45588" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45588" }, { "date": "2022-12-27T01:44:00", "db": "JVNDB", "id": "JVNDB-2021-016910" }, { "date": "2022-01-04T20:27:56.343000", "db": "NVD", "id": "CVE-2021-45588" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2385" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2385" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016910" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2385" } ], "trust": 0.6 } }
var-202108-1619
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, MK62 before 1.0.6.110, MR60 before 1.0.6.110, MS60 before 1.0.6.110, RBK752 before 3.2.10.10, RBR750 before 3.2.10.10, and RBS750 before 3.2.10.10. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Netgear RBR750 is a home WiFi system from Netgear.
Several NETGEAR devices have an access control error vulnerability that stems from the product not properly restricting access from unauthorized roles. No detailed vulnerability details are currently provided. This affects RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.48, MK62 prior to 1.0.6.110, MR60 prior to 1.0.6.110, MS60 prior to 1.0.6.110, RBK752 prior to 3.2.10.10, RBR750 prior to 3.2.10.10, and RBS750 prior to 3.2.10.10
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1619", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "cbr40", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "mk62", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "mr60", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "ms60", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "eax20", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.10.10" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.10.10" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.10.10" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "NVD", "id": "CVE-2021-38513" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38513" } ] }, "cve": "CVE-2021-38513", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-38513", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2022-06698", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-38513", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-38513", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-38513", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2022-06698", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202108-963", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-38513", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "VULMON", "id": "CVE-2021-38513" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "NVD", "id": "CVE-2021-38513" }, { "db": "NVD", "id": "CVE-2021-38513" }, { "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, MK62 before 1.0.6.110, MR60 before 1.0.6.110, MS60 before 1.0.6.110, RBK752 before 3.2.10.10, RBR750 before 3.2.10.10, and RBS750 before 3.2.10.10. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Netgear RBR750 is a home WiFi system from Netgear. \n\r\n\r\nSeveral NETGEAR devices have an access control error vulnerability that stems from the product not properly restricting access from unauthorized roles. No detailed vulnerability details are currently provided. This affects RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.48, MK62 prior to 1.0.6.110, MR60 prior to 1.0.6.110, MS60 prior to 1.0.6.110, RBK752 prior to 3.2.10.10, RBR750 prior to 3.2.10.10, and RBS750 prior to 3.2.10.10", "sources": [ { "db": "NVD", "id": "CVE-2021-38513" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "VULMON", "id": "CVE-2021-38513" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-38513", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2021-010413", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-06698", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202108-963", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-38513", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "VULMON", "id": "CVE-2021-38513" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "NVD", "id": "CVE-2021-38513" }, { "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "id": "VAR-202108-1619", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" } ], "trust": 0.86324803 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" } ] }, "last_update_date": "2023-12-18T13:37:19.055000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0Extenders\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0008", "trust": 0.8, "url": "https://kb.netgear.com/000063777/security-advisory-for-authentication-bypass-on-some-extenders-and-wifi-systems-psv-2020-0008" }, { "title": "Patch for Netgear RBR750 Access Control Error Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/316041" }, { "title": "Netgear RBR750 Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159357" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inappropriate authentication (CWE-287) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "NVD", "id": "CVE-2021-38513" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38513" }, { "trust": 1.7, "url": "https://kb.netgear.com/000063777/security-advisory-for-authentication-bypass-on-some-extenders-and-wifi-systems-psv-2020-0008" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "VULMON", "id": "CVE-2021-38513" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "NVD", "id": "CVE-2021-38513" }, { "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-06698" }, { "db": "VULMON", "id": "CVE-2021-38513" }, { "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "db": "NVD", "id": "CVE-2021-38513" }, { "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2022-06698" }, { "date": "2021-08-11T00:00:00", "db": "VULMON", "id": "CVE-2021-38513" }, { "date": "2022-07-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "date": "2021-08-11T00:15:10.787000", "db": "NVD", "id": "CVE-2021-38513" }, { "date": "2021-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2022-06698" }, { "date": "2021-08-18T00:00:00", "db": "VULMON", "id": "CVE-2021-38513" }, { "date": "2022-07-01T01:56:00", "db": "JVNDB", "id": "JVNDB-2021-010413" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-38513" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-963" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-963" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Authentication vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010413" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-963" } ], "trust": 0.6 } }
var-202006-0584
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, RBK842 prior to 3.2.10.11, RBR840 prior to 3.2.10.11, and RBS840 prior to 3.2.10.11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0584", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk842", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 0.6, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14426" } ] }, "cve": "CVE-2020-14426", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006747", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44773", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14426", "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "LOW", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006747", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14426", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14426", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006747", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44773", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1239", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14426", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, RBK842 prior to 3.2.10.11, RBR840 prior to 3.2.10.11, and RBS840 prior to 3.2.10.11", "sources": [ { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14426", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2020-006747", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44773", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1239", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14426", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "id": "VAR-202006-0584", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" } ] }, "last_update_date": "2023-12-18T13:33:02.339000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some Wifi Systems, PSV-2020-0033", "trust": 0.8, "url": "https://kb.netgear.com/000061931/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0033" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44773)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275071" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121988" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14426" }, { "trust": 1.7, "url": "https://kb.netgear.com/000061931/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0033" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14426" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44773" }, { "db": "VULMON", "id": "CVE-2020-14426" }, { "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "db": "NVD", "id": "CVE-2020-14426" }, { "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44773" }, { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14426" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "date": "2020-06-18T17:15:11.813000", "db": "NVD", "id": "CVE-2020-14426" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44773" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14426" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006747" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14426" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1239" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1239" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006747" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1239" } ], "trust": 0.6 } }
var-202112-2384
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2384", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "NVD", "id": "CVE-2021-45564" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45564" } ] }, "cve": "CVE-2021-45564", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45564", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45564", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45564", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45564", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2296", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45564", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45564" }, { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "NVD", "id": "CVE-2021-45564" }, { "db": "NVD", "id": "CVE-2021-45564" }, { "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45564" }, { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "VULMON", "id": "CVE-2021-45564" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45564", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016899", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2296", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45564", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45564" }, { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "NVD", "id": "CVE-2021-45564" }, { "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "id": "VAR-202112-2384", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T11:56:47.558000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0067", "trust": 0.8, "url": "https://kb.netgear.com/000064085/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0067" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177058" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "NVD", "id": "CVE-2021-45564" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064085/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0067" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45564" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45564" }, { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "NVD", "id": "CVE-2021-45564" }, { "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45564" }, { "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "db": "NVD", "id": "CVE-2021-45564" }, { "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45564" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "date": "2021-12-26T01:15:16.040000", "db": "NVD", "id": "CVE-2021-45564" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45564" }, { "date": "2022-12-26T08:05:00", "db": "JVNDB", "id": "JVNDB-2021-016899" }, { "date": "2022-01-04T19:34:25.520000", "db": "NVD", "id": "CVE-2021-45564" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2296" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2296" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016899" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2296" } ], "trust": 0.6 } }
var-202112-2386
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Netgear NETGEAR is a router from Netgear. A hardware device that connects two or more networks and acts as a gateway between the networks.
A security vulnerability exists in some NETGEAR devices. Attackers can exploit this vulnerability to perform command injection. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2386", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.6, "vendor": "netgear", "version": null } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "NVD", "id": "CVE-2021-45562" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45562" } ] }, "cve": "CVE-2021-45562", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45562", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "id": "CNVD-2022-06686", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45562", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45562", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45562", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2022-06686", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2293", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45562", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "VULMON", "id": "CVE-2021-45562" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "NVD", "id": "CVE-2021-45562" }, { "db": "NVD", "id": "CVE-2021-45562" }, { "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Netgear NETGEAR is a router from Netgear. A hardware device that connects two or more networks and acts as a gateway between the networks. \n\r\n\r\nA security vulnerability exists in some NETGEAR devices. Attackers can exploit this vulnerability to perform command injection. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45562" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "VULMON", "id": "CVE-2021-45562" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45562", "trust": 3.9 }, { "db": "JVNDB", "id": "JVNDB-2021-016905", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-06686", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202112-2293", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45562", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "VULMON", "id": "CVE-2021-45562" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "NVD", "id": "CVE-2021-45562" }, { "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "id": "VAR-202112-2386", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" } ], "trust": 0.74124016 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" } ] }, "last_update_date": "2023-12-18T13:17:34.413000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0060", "trust": 0.8, "url": "https://kb.netgear.com/000064082/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0060" }, { "title": "Patch for NETGEAR RBR750 Command Injection Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/315986" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177055" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "NVD", "id": "CVE-2021-45562" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45562" }, { "trust": 1.7, "url": "https://kb.netgear.com/000064082/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0060" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "VULMON", "id": "CVE-2021-45562" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "NVD", "id": "CVE-2021-45562" }, { "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-06686" }, { "db": "VULMON", "id": "CVE-2021-45562" }, { "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "db": "NVD", "id": "CVE-2021-45562" }, { "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2022-06686" }, { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45562" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "date": "2021-12-26T01:15:15.940000", "db": "NVD", "id": "CVE-2021-45562" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-25T00:00:00", "db": "CNVD", "id": "CNVD-2022-06686" }, { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45562" }, { "date": "2022-12-26T08:53:00", "db": "JVNDB", "id": "JVNDB-2021-016905" }, { "date": "2022-01-04T19:39:12.397000", "db": "NVD", "id": "CVE-2021-45562" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2293" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2293" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016905" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2293" } ], "trust": 0.6 } }
var-202112-2374
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2374", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "NVD", "id": "CVE-2021-45574" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45574" } ] }, "cve": "CVE-2021-45574", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45574", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45574", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45574", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45574", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2303", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45574", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45574" }, { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "NVD", "id": "CVE-2021-45574" }, { "db": "NVD", "id": "CVE-2021-45574" }, { "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45574" }, { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "VULMON", "id": "CVE-2021-45574" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45574", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016892", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2303", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45574", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45574" }, { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "NVD", "id": "CVE-2021-45574" }, { "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "id": "VAR-202112-2374", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:59:53.798000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0082", "trust": 0.8, "url": "https://kb.netgear.com/000064096/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0082" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177065" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "NVD", "id": "CVE-2021-45574" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064096/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0082" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45574" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45574" }, { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "NVD", "id": "CVE-2021-45574" }, { "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45574" }, { "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "db": "NVD", "id": "CVE-2021-45574" }, { "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45574" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "date": "2021-12-26T01:15:16.507000", "db": "NVD", "id": "CVE-2021-45574" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45574" }, { "date": "2022-12-26T07:29:00", "db": "JVNDB", "id": "JVNDB-2021-016892" }, { "date": "2022-01-04T20:42:10.813000", "db": "NVD", "id": "CVE-2021-45574" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2303" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2303" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016892" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2303" } ], "trust": 0.6 } }
var-202010-0570
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0570", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "db": "NVD", "id": "CVE-2020-26904" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26904" } ] }, "cve": "CVE-2020-26904", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26904", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26904", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26904", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26904", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-335", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "db": "NVD", "id": "CVE-2020-26904" }, { "db": "NVD", "id": "CVE-2020-26904" }, { "db": "CNNVD", "id": "CNNVD-202010-335" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26904" }, { "db": "JVNDB", "id": "JVNDB-2020-012222" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26904", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012222", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-335", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "db": "NVD", "id": "CVE-2020-26904" }, { "db": "CNNVD", "id": "CNNVD-202010-335" } ] }, "id": "VAR-202010-0570", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:42:49.505000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0046", "trust": 0.8, "url": "https://kb.netgear.com/000062350/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0046" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "db": "NVD", "id": "CVE-2020-26904" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062350/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0046" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26904" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "db": "NVD", "id": "CVE-2020-26904" }, { "db": "CNNVD", "id": "CNNVD-202010-335" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "db": "NVD", "id": "CVE-2020-26904" }, { "db": "CNNVD", "id": "CNNVD-202010-335" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "date": "2020-10-09T07:15:16.107000", "db": "NVD", "id": "CVE-2020-26904" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-335" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:44:00", "db": "JVNDB", "id": "JVNDB-2020-012222" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26904" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-335" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-335" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials on devices Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012222" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-335" } ], "trust": 0.6 } }
var-202112-2316
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2316", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "NVD", "id": "CVE-2021-45633" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45633" } ] }, "cve": "CVE-2021-45633", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45633", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45633", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45633", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45633", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2433", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45633", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45633" }, { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "NVD", "id": "CVE-2021-45633" }, { "db": "NVD", "id": "CVE-2021-45633" }, { "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45633" }, { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "VULMON", "id": "CVE-2021-45633" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45633", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017039", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2433", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45633", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45633" }, { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "NVD", "id": "CVE-2021-45633" }, { "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "id": "VAR-202112-2316", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T14:04:08.898000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0514", "trust": 0.8, "url": "https://kb.netgear.com/000064511/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0514" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176671" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "NVD", "id": "CVE-2021-45633" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064511/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0514" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45633" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45633" }, { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "NVD", "id": "CVE-2021-45633" }, { "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45633" }, { "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "db": "NVD", "id": "CVE-2021-45633" }, { "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45633" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "date": "2021-12-26T01:15:19.323000", "db": "NVD", "id": "CVE-2021-45633" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45633" }, { "date": "2022-12-28T02:43:00", "db": "JVNDB", "id": "JVNDB-2021-017039" }, { "date": "2022-01-05T18:22:54.557000", "db": "NVD", "id": "CVE-2021-45633" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2433" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2433" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017039" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2433" } ], "trust": 0.6 } }
var-202006-0933
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
Injection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0933", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14436" } ] }, "cve": "CVE-2020-14436", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006741", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44781", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006741", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14436", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14436", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006741", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44781", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1252", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "CNVD", "id": "CNVD-2021-44781" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14436", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006741", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44781", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1252", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" } ] }, "id": "VAR-202006-0933", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" } ] }, "last_update_date": "2023-12-18T13:51:53.574000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentication Command Injection on Some WiFi Systems, PSV-2020-0039", "trust": 0.8, "url": "https://kb.netgear.com/000061933/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0039" }, { "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44781)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275081" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14436" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061933/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0039" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14436" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44781" }, { "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "db": "NVD", "id": "CVE-2020-14436" }, { "db": "CNNVD", "id": "CNNVD-202006-1252" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44781" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "date": "2020-06-18T17:15:12.750000", "db": "NVD", "id": "CVE-2020-14436" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1252" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44781" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006741" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14436" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1252" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1252" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006741" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1252" } ], "trust": 0.6 } }
var-202103-1274
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBR752 prior to 3.2.17.12, RBR753 prior to 3.2.17.12, RBR753S prior to 3.2.17.12, RBR754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1274", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29071" } ] }, "cve": "CVE-2021-29071", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29071", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.3, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.0, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29071", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29071", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29071", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1355", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29071", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBR752 prior to 3.2.17.12, RBR753 prior to 3.2.17.12, RBR753S prior to 3.2.17.12, RBR754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "VULMON", "id": "CVE-2021-29071" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29071", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004577", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1355", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29071", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "id": "VAR-202103-1274", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.25306323 }, "last_update_date": "2023-12-18T14:00:11.923000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0476", "trust": 0.8, "url": "https://kb.netgear.com/000063008/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0476" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=144973" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063008/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0476" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29071" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29071" }, { "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "db": "NVD", "id": "CVE-2021-29071" }, { "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29071" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "date": "2021-03-23T07:15:13.560000", "db": "NVD", "id": "CVE-2021-29071" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29071" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004577" }, { "date": "2021-03-24T19:40:11.363000", "db": "NVD", "id": "CVE-2021-29071" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1355" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1355" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004577" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1355" } ], "trust": 0.6 } }
var-202108-1624
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1624", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38518" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38518" } ] }, "cve": "CVE-2021-38518", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-38518", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "id": "CVE-2021-38518", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-38518", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202108-958", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-38518", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38518" }, { "db": "CNNVD", "id": "CNNVD-202108-958" }, { "db": "NVD", "id": "CVE-2021-38518" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-38518" }, { "db": "VULMON", "id": "CVE-2021-38518" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-38518", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202108-958", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-38518", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38518" }, { "db": "CNNVD", "id": "CNNVD-202108-958" }, { "db": "NVD", "id": "CVE-2021-38518" } ] }, "id": "VAR-202108-1624", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.2019032275 }, "last_update_date": "2022-05-04T09:41:58.436000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159352" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-958" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38518" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063783/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0528" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38518" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38518" }, { "db": "CNNVD", "id": "CNNVD-202108-958" }, { "db": "NVD", "id": "CVE-2021-38518" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-38518" }, { "db": "CNNVD", "id": "CNNVD-202108-958" }, { "db": "NVD", "id": "CVE-2021-38518" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-11T00:00:00", "db": "VULMON", "id": "CVE-2021-38518" }, { "date": "2021-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-958" }, { "date": "2021-08-11T00:15:00", "db": "NVD", "id": "CVE-2021-38518" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-18T00:00:00", "db": "VULMON", "id": "CVE-2021-38518" }, { "date": "2021-08-19T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-958" }, { "date": "2021-08-18T19:37:00", "db": "NVD", "id": "CVE-2021-38518" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-958" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-958" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-958" } ], "trust": 0.6 } }
var-202108-1633
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.14, EX6100v2 prior to 1.0.1.98, EX6150v2 prior to 1.0.1.98, EX6250 prior to 1.0.0.132, EX6400 prior to 1.0.2.158, EX6400v2 prior to 1.0.0.132, EX6410 prior to 1.0.0.132, EX6420 prior to 1.0.0.132, EX7300 prior to 1.0.2.158, EX7300v2 prior to 1.0.0.132, EX7320 prior to 1.0.0.132, EX7700 prior to 1.0.0.216, EX8000 prior to 1.0.1.232, R7800 prior to 1.0.2.78, RBK12 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, RBK20 prior to 2.6.1.38, RBR20 prior to 2.6.1.36, RBS20 prior to 2.6.1.38, RBK40 prior to 2.6.1.38, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBS40V prior to 2.6.2.4, RBS50Y prior to 2.6.1.40, RBW30 prior to 2.6.2.2, and XR500 prior to 2.3.2.114
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202108-1633", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbs10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "ex6150", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.98" }, { "model": "ex7700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.216" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.14" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.132" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "ex6100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.98" }, { "model": "ex8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.232" }, { "model": "ex6420", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.132" }, { "model": "ex7300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.158" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.78" }, { "model": "ex6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.158" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.114" }, { "model": "ex7320", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.132" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "ex6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.132" }, { "model": "ex6410", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.132" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk12", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs50y", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "ex7300", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6100", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7320", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6410", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6150", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6250", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6420", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "NVD", "id": "CVE-2021-38527" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.14", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.158", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6400:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6420_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6420:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.158", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.158", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7300:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.216", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.232", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk12:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.114", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-38527" } ] }, "cve": "CVE-2021-38527", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-38527", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-38527", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-38527", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-38527", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202108-993", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-38527", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38527" }, { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "NVD", "id": "CVE-2021-38527" }, { "db": "NVD", "id": "CVE-2021-38527" }, { "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.14, EX6100v2 prior to 1.0.1.98, EX6150v2 prior to 1.0.1.98, EX6250 prior to 1.0.0.132, EX6400 prior to 1.0.2.158, EX6400v2 prior to 1.0.0.132, EX6410 prior to 1.0.0.132, EX6420 prior to 1.0.0.132, EX7300 prior to 1.0.2.158, EX7300v2 prior to 1.0.0.132, EX7320 prior to 1.0.0.132, EX7700 prior to 1.0.0.216, EX8000 prior to 1.0.1.232, R7800 prior to 1.0.2.78, RBK12 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, RBK20 prior to 2.6.1.38, RBR20 prior to 2.6.1.36, RBS20 prior to 2.6.1.38, RBK40 prior to 2.6.1.38, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBS40V prior to 2.6.2.4, RBS50Y prior to 2.6.1.40, RBW30 prior to 2.6.2.2, and XR500 prior to 2.3.2.114", "sources": [ { "db": "NVD", "id": "CVE-2021-38527" }, { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "VULMON", "id": "CVE-2021-38527" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-38527", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-010445", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202108-993", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-38527", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38527" }, { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "NVD", "id": "CVE-2021-38527" }, { "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "id": "VAR-202108-1633", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26302805312500005 }, "last_update_date": "2023-12-18T13:12:25.502000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Extenders,\u00a0Routers,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0025", "trust": 0.8, "url": "https://kb.netgear.com/000063778/security-advisory-for-pre-authentication-command-injection-on-some-extenders-routers-and-wifi-systems-psv-2020-0025" }, { "title": "Netgear RBR750 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=159380" }, { "title": "CVE-2021-38527", "trust": 0.1, "url": "https://github.com/alaial90/cve-2021-38527 " } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38527" }, { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "NVD", "id": "CVE-2021-38527" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063778/security-advisory-for-pre-authentication-command-injection-on-some-extenders-routers-and-wifi-systems-psv-2020-0025" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-38527" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://github.com/alaial90/cve-2021-38527" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-38527" }, { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "NVD", "id": "CVE-2021-38527" }, { "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-38527" }, { "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "db": "NVD", "id": "CVE-2021-38527" }, { "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-11T00:00:00", "db": "VULMON", "id": "CVE-2021-38527" }, { "date": "2022-07-01T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "date": "2021-08-11T00:16:18.947000", "db": "NVD", "id": "CVE-2021-38527" }, { "date": "2021-08-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-08-19T00:00:00", "db": "VULMON", "id": "CVE-2021-38527" }, { "date": "2022-07-01T06:12:00", "db": "JVNDB", "id": "JVNDB-2021-010445" }, { "date": "2021-08-19T18:37:36.557000", "db": "NVD", "id": "CVE-2021-38527" }, { "date": "2022-03-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202108-993" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-993" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-010445" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202108-993" } ], "trust": 0.6 } }
var-202112-2334
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000P prior to 1.4.2.84, R8300 prior to 1.0.2.154, R8500 prior to 1.0.2.154, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2334", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.154" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "r8300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.154" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8300", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "NVD", "id": "CVE-2021-45615" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45615" } ] }, "cve": "CVE-2021-45615", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45615", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45615", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45615", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45615", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2410", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45615", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45615" }, { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "NVD", "id": "CVE-2021-45615" }, { "db": "NVD", "id": "CVE-2021-45615" }, { "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000P prior to 1.4.2.84, R8300 prior to 1.0.2.154, R8500 prior to 1.0.2.154, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45615" }, { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "VULMON", "id": "CVE-2021-45615" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45615", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017087", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2410", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45615", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45615" }, { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "NVD", "id": "CVE-2021-45615" }, { "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "id": "VAR-202112-2334", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.337142476 }, "last_update_date": "2023-12-18T13:51:16.302000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0521", "trust": 0.8, "url": "https://kb.netgear.com/000064514/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0521" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176389" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "NVD", "id": "CVE-2021-45615" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064514/security-advisory-for-pre-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0521" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45615" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45615" }, { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "NVD", "id": "CVE-2021-45615" }, { "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45615" }, { "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "db": "NVD", "id": "CVE-2021-45615" }, { "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45615" }, { "date": "2023-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "date": "2021-12-26T01:15:18.473000", "db": "NVD", "id": "CVE-2021-45615" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45615" }, { "date": "2023-01-04T01:52:00", "db": "JVNDB", "id": "JVNDB-2021-017087" }, { "date": "2022-01-05T19:18:51.920000", "db": "NVD", "id": "CVE-2021-45615" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2410" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2410" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017087" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2410" } ], "trust": 0.6 } }
var-202112-2315
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2315", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "NVD", "id": "CVE-2021-45634" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45634" } ] }, "cve": "CVE-2021-45634", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45634", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45634", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45634", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45634", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2429", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45634", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45634" }, { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "NVD", "id": "CVE-2021-45634" }, { "db": "NVD", "id": "CVE-2021-45634" }, { "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45634" }, { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "VULMON", "id": "CVE-2021-45634" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45634", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017037", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2429", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45634", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45634" }, { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "NVD", "id": "CVE-2021-45634" }, { "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "id": "VAR-202112-2315", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:12:15.414000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0515", "trust": 0.8, "url": "https://kb.netgear.com/000064139/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0515" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176667" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "NVD", "id": "CVE-2021-45634" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064139/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0515" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45634" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45634" }, { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "NVD", "id": "CVE-2021-45634" }, { "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45634" }, { "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "db": "NVD", "id": "CVE-2021-45634" }, { "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45634" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "date": "2021-12-26T01:15:19.367000", "db": "NVD", "id": "CVE-2021-45634" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45634" }, { "date": "2022-12-28T02:32:00", "db": "JVNDB", "id": "JVNDB-2021-017037" }, { "date": "2022-01-05T18:23:15.287000", "db": "NVD", "id": "CVE-2021-45634" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2429" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2429" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017037" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2429" } ], "trust": 0.6 } }
var-202112-2363
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2363", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "NVD", "id": "CVE-2021-45586" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45586" } ] }, "cve": "CVE-2021-45586", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45586", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45586", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45586", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45586", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2383", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45586", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45586" }, { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "NVD", "id": "CVE-2021-45586" }, { "db": "NVD", "id": "CVE-2021-45586" }, { "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45586" }, { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "VULMON", "id": "CVE-2021-45586" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45586", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016908", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2383", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45586", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45586" }, { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "NVD", "id": "CVE-2021-45586" }, { "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "id": "VAR-202112-2363", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T11:56:47.581000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0094", "trust": 0.8, "url": "https://kb.netgear.com/000064108/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0094" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177098" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "NVD", "id": "CVE-2021-45586" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064108/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0094" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45586" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45586" }, { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "NVD", "id": "CVE-2021-45586" }, { "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45586" }, { "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "db": "NVD", "id": "CVE-2021-45586" }, { "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45586" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "date": "2021-12-26T01:15:17.070000", "db": "NVD", "id": "CVE-2021-45586" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45586" }, { "date": "2022-12-27T01:39:00", "db": "JVNDB", "id": "JVNDB-2021-016908" }, { "date": "2022-01-04T20:31:43.563000", "db": "NVD", "id": "CVE-2021-45586" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2383" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2383" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016908" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2383" } ], "trust": 0.6 } }
var-202112-2376
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2376", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "NVD", "id": "CVE-2021-45572" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45572" } ] }, "cve": "CVE-2021-45572", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45572", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45572", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45572", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45572", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2302", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45572", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45572" }, { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "NVD", "id": "CVE-2021-45572" }, { "db": "NVD", "id": "CVE-2021-45572" }, { "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45572" }, { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "VULMON", "id": "CVE-2021-45572" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45572", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016891", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2302", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45572", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45572" }, { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "NVD", "id": "CVE-2021-45572" }, { "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "id": "VAR-202112-2376", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:12:15.363000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0080", "trust": 0.8, "url": "https://kb.netgear.com/000064094/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0080" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177064" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "NVD", "id": "CVE-2021-45572" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064094/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0080" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45572" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45572" }, { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "NVD", "id": "CVE-2021-45572" }, { "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45572" }, { "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "db": "NVD", "id": "CVE-2021-45572" }, { "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45572" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "date": "2021-12-26T01:15:16.417000", "db": "NVD", "id": "CVE-2021-45572" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45572" }, { "date": "2022-12-26T07:26:00", "db": "JVNDB", "id": "JVNDB-2021-016891" }, { "date": "2022-01-04T19:41:45.047000", "db": "NVD", "id": "CVE-2021-45572" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2302" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2302" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016891" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2302" } ], "trust": 0.6 } }
var-202112-2360
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2360", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "NVD", "id": "CVE-2021-45589" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45589" } ] }, "cve": "CVE-2021-45589", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45589", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45589", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45589", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45589", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2382", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45589", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45589" }, { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "NVD", "id": "CVE-2021-45589" }, { "db": "NVD", "id": "CVE-2021-45589" }, { "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45589" }, { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "VULMON", "id": "CVE-2021-45589" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45589", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016972", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2382", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45589", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45589" }, { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "NVD", "id": "CVE-2021-45589" }, { "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "id": "VAR-202112-2360", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:55:16.674000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0097", "trust": 0.8, "url": "https://kb.netgear.com/000064111/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0097" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177095" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "NVD", "id": "CVE-2021-45589" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064111/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0097" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45589" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45589" }, { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "NVD", "id": "CVE-2021-45589" }, { "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45589" }, { "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "db": "NVD", "id": "CVE-2021-45589" }, { "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45589" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "date": "2021-12-26T01:15:17.210000", "db": "NVD", "id": "CVE-2021-45589" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45589" }, { "date": "2022-12-27T05:39:00", "db": "JVNDB", "id": "JVNDB-2021-016972" }, { "date": "2022-01-04T20:26:51.037000", "db": "NVD", "id": "CVE-2021-45589" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2382" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2382" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016972" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2382" } ], "trust": 0.6 } }
var-202103-1277
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1277", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29074" } ] }, "cve": "CVE-2021-29074", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29074", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004580", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29074", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29074", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1350", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29074", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "VULMON", "id": "CVE-2021-29074" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29074", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004580", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1350", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29074", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "id": "VAR-202103-1277", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.318865984 }, "last_update_date": "2023-12-18T13:32:43.158000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0467", "trust": 0.8, "url": "https://kb.netgear.com/000063011/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-routers-psv-2020-0467" }, { "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145889" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063011/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-routers-psv-2020-0467" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29074" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29074" }, { "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "db": "NVD", "id": "CVE-2021-29074" }, { "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29074" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "date": "2021-03-23T07:15:13.797000", "db": "NVD", "id": "CVE-2021-29074" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29074" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004580" }, { "date": "2021-03-24T20:27:30.243000", "db": "NVD", "id": "CVE-2021-29074" }, { "date": "2021-03-31T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1350" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1350" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004580" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1350" } ], "trust": 0.6 } }
var-202112-2364
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2364", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "NVD", "id": "CVE-2021-45585" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45585" } ] }, "cve": "CVE-2021-45585", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45585", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45585", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45585", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45585", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2381", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45585", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45585" }, { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "NVD", "id": "CVE-2021-45585" }, { "db": "NVD", "id": "CVE-2021-45585" }, { "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45585" }, { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "VULMON", "id": "CVE-2021-45585" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45585", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016907", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2381", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45585", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45585" }, { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "NVD", "id": "CVE-2021-45585" }, { "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "id": "VAR-202112-2364", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:22:38.162000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0093", "trust": 0.8, "url": "https://kb.netgear.com/000064107/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0093" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177094" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "NVD", "id": "CVE-2021-45585" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064107/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0093" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45585" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45585" }, { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "NVD", "id": "CVE-2021-45585" }, { "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45585" }, { "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "db": "NVD", "id": "CVE-2021-45585" }, { "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45585" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "date": "2021-12-26T01:15:17.027000", "db": "NVD", "id": "CVE-2021-45585" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45585" }, { "date": "2022-12-27T01:37:00", "db": "JVNDB", "id": "JVNDB-2021-016907" }, { "date": "2022-01-04T20:32:34.070000", "db": "NVD", "id": "CVE-2021-45585" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2381" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2381" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016907" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2381" } ], "trust": 0.6 } }
var-202112-2367
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2367", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "NVD", "id": "CVE-2021-45581" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45581" } ] }, "cve": "CVE-2021-45581", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45581", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45581", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45581", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45581", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2375", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45581", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45581" }, { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "NVD", "id": "CVE-2021-45581" }, { "db": "NVD", "id": "CVE-2021-45581" }, { "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45581" }, { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "VULMON", "id": "CVE-2021-45581" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45581", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016912", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2375", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45581", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45581" }, { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "NVD", "id": "CVE-2021-45581" }, { "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "id": "VAR-202112-2367", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:06:53.556000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0089", "trust": 0.8, "url": "https://kb.netgear.com/000064103/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0089" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177083" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "NVD", "id": "CVE-2021-45581" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064103/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0089" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45581" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45581" }, { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "NVD", "id": "CVE-2021-45581" }, { "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45581" }, { "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "db": "NVD", "id": "CVE-2021-45581" }, { "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45581" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "date": "2021-12-26T01:15:16.843000", "db": "NVD", "id": "CVE-2021-45581" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45581" }, { "date": "2022-12-27T02:08:00", "db": "JVNDB", "id": "JVNDB-2021-016912" }, { "date": "2022-01-04T20:35:07.787000", "db": "NVD", "id": "CVE-2021-45581" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2375" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2375" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016912" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2375" } ], "trust": 0.6 } }
var-202006-0931
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0931", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14434" } ] }, "cve": "CVE-2020-14434", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.7, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "JVNDB-2020-006745", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 5.1, "id": "CNVD-2021-44779", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006745", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14434", "trust": 1.0, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-14434", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-006745", "trust": 0.8, "value": "Medium" }, { "author": "CNVD", "id": "CNVD-2021-44779", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202006-1250", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "CNVD", "id": "CNVD-2021-44779" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14434", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006745", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44779", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1250", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" } ] }, "id": "VAR-202006-0931", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" } ] }, "last_update_date": "2023-12-18T14:04:41.978000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Post-Authentication Command Injection on Some WiFi Systems, PSV-2020-0040", "trust": 0.8, "url": "https://kb.netgear.com/000061934/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0040" }, { "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44779)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275091" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-74", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14434" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061934/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0040" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14434" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44779" }, { "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "db": "NVD", "id": "CVE-2020-14434" }, { "db": "CNNVD", "id": "CNNVD-202006-1250" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44779" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "date": "2020-06-18T17:15:12.547000", "db": "NVD", "id": "CVE-2020-14434" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1250" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44779" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006745" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14434" }, { "date": "2020-06-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1250" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1250" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006745" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1250" } ], "trust": 0.6 } }
var-202112-2415
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects EX6120 before 1.0.0.66, EX6130 before 1.0.0.46, EX7000 before 1.0.1.106, EX7500 before 1.0.1.76, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, RBR850 before 4.6.3.9, RBS850 before 4.6.3.9, and RBK852 before 4.6.3.9. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects EX6120 prior to 1.0.0.66, EX6130 prior to 1.0.0.46, EX7000 prior to 1.0.1.106, EX7500 prior to 1.0.1.76, EX3700 prior to 1.0.0.94, EX3800 prior to 1.0.0.94, RBR850 prior to 4.6.3.9, RBS850 prior to 4.6.3.9, and RBK852 prior to 4.6.3.9
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2415", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.9" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.94" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.76" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.9" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.9" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.94" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.106" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex3800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex3700", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6130", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "NVD", "id": "CVE-2021-45533" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.9", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.9", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.9", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45533" } ] }, "cve": "CVE-2021-45533", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45533", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45533", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45533", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45533", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2352", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45533", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45533" }, { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "NVD", "id": "CVE-2021-45533" }, { "db": "NVD", "id": "CVE-2021-45533" }, { "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects EX6120 before 1.0.0.66, EX6130 before 1.0.0.46, EX7000 before 1.0.1.106, EX7500 before 1.0.1.76, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, RBR850 before 4.6.3.9, RBS850 before 4.6.3.9, and RBK852 before 4.6.3.9. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects EX6120 prior to 1.0.0.66, EX6130 prior to 1.0.0.46, EX7000 prior to 1.0.1.106, EX7500 prior to 1.0.1.76, EX3700 prior to 1.0.0.94, EX3800 prior to 1.0.0.94, RBR850 prior to 4.6.3.9, RBS850 prior to 4.6.3.9, and RBK852 prior to 4.6.3.9", "sources": [ { "db": "NVD", "id": "CVE-2021-45533" }, { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "VULMON", "id": "CVE-2021-45533" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45533", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017116", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2352", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45533", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45533" }, { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "NVD", "id": "CVE-2021-45533" }, { "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "id": "VAR-202112-2415", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.33499898833333336 }, "last_update_date": "2023-12-18T12:26:30.236000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Extenders\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0062", "trust": 0.8, "url": "https://kb.netgear.com/000064458/security-advisory-for-post-authentication-command-injection-on-some-extenders-and-wifi-systems-psv-2020-0062" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176385" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "NVD", "id": "CVE-2021-45533" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064458/security-advisory-for-post-authentication-command-injection-on-some-extenders-and-wifi-systems-psv-2020-0062" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45533" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45533" }, { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "NVD", "id": "CVE-2021-45533" }, { "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45533" }, { "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "db": "NVD", "id": "CVE-2021-45533" }, { "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45533" }, { "date": "2023-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "date": "2021-12-26T01:15:14.553000", "db": "NVD", "id": "CVE-2021-45533" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45533" }, { "date": "2023-01-04T06:53:00", "db": "JVNDB", "id": "JVNDB-2021-017116" }, { "date": "2022-01-05T15:41:58.363000", "db": "NVD", "id": "CVE-2021-45533" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2352" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2352" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017116" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2352" } ], "trust": 0.6 } }
var-202112-2219
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2219", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "NVD", "id": "CVE-2021-45502" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45502" } ] }, "cve": "CVE-2021-45502", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45502", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45502", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45502", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45502", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2319", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45502", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45502" }, { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "NVD", "id": "CVE-2021-45502" }, { "db": "NVD", "id": "CVE-2021-45502" }, { "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45502" }, { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "VULMON", "id": "CVE-2021-45502" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45502", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017140", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2319", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45502", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45502" }, { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "NVD", "id": "CVE-2021-45502" }, { "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "id": "VAR-202112-2219", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:01:00.262000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0473", "trust": 0.8, "url": "https://kb.netgear.com/000064126/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0473" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176038" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "NVD", "id": "CVE-2021-45502" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064126/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0473" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45502" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45502" }, { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "NVD", "id": "CVE-2021-45502" }, { "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45502" }, { "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "db": "NVD", "id": "CVE-2021-45502" }, { "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45502" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "date": "2021-12-26T01:15:12.983000", "db": "NVD", "id": "CVE-2021-45502" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45502" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017140" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45502" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2319" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2319" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017140" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2319" } ], "trust": 0.6 } }
var-202112-2345
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects CBR750 before 3.2.18.2, D6220 before 1.0.0.68, D6400 before 1.0.0.102, D8500 before 1.0.3.60, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58. plural NETGEAR The device contains a vulnerability related to out-of-bounds writes.Service operation interruption (DoS) It may be in a state. This affects CBR750 prior to 3.2.18.2, D6220 prior to 1.0.0.68, D6400 prior to 1.0.0.102, D8500 prior to 1.0.3.60, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6300v2 prior to 1.0.4.50, R6400 prior to 1.0.1.68, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.116, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, and XR1000 prior to 1.0.0.58
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2345", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.18.2" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.60" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax35", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r6300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.50" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r6700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.102" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6300", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6220", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "NVD", "id": "CVE-2021-45604" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40:v2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45604" } ] }, "cve": "CVE-2021-45604", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 2.7, "confidentialityImpact": "NONE", "exploitabilityScore": 5.1, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 2.7, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45604", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 0.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 4.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-017178", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45604", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45604", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2400", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45604", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45604" }, { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "NVD", "id": "CVE-2021-45604" }, { "db": "NVD", "id": "CVE-2021-45604" }, { "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects CBR750 before 3.2.18.2, D6220 before 1.0.0.68, D6400 before 1.0.0.102, D8500 before 1.0.3.60, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58. plural NETGEAR The device contains a vulnerability related to out-of-bounds writes.Service operation interruption (DoS) It may be in a state. This affects CBR750 prior to 3.2.18.2, D6220 prior to 1.0.0.68, D6400 prior to 1.0.0.102, D8500 prior to 1.0.3.60, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6300v2 prior to 1.0.4.50, R6400 prior to 1.0.1.68, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.116, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, and XR1000 prior to 1.0.0.58", "sources": [ { "db": "NVD", "id": "CVE-2021-45604" }, { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "VULMON", "id": "CVE-2021-45604" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45604", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017178", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2400", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45604", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45604" }, { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "NVD", "id": "CVE-2021-45604" }, { "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "id": "VAR-202112-2345", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3284446809523809 }, "last_update_date": "2023-12-18T12:34:42.554000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0572", "trust": 0.8, "url": "https://kb.netgear.com/000064526/security-advisory-for-post-authentication-stack-overflow-on-some-routers-and-wifi-systems-psv-2020-0572" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177121" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "NVD", "id": "CVE-2021-45604" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064526/security-advisory-for-post-authentication-stack-overflow-on-some-routers-and-wifi-systems-psv-2020-0572" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45604" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45604" }, { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "NVD", "id": "CVE-2021-45604" }, { "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45604" }, { "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "db": "NVD", "id": "CVE-2021-45604" }, { "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45604" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "date": "2021-12-26T01:15:17.900000", "db": "NVD", "id": "CVE-2021-45604" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45604" }, { "date": "2023-01-06T06:15:00", "db": "JVNDB", "id": "JVNDB-2021-017178" }, { "date": "2022-01-06T14:57:14.883000", "db": "NVD", "id": "CVE-2021-45604" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2400" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2400" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017178" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2400" } ], "trust": 0.6 } }
var-202112-2381
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2381", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "NVD", "id": "CVE-2021-45567" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45567" } ] }, "cve": "CVE-2021-45567", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45567", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45567", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45567", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45567", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2297", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45567", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45567" }, { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "NVD", "id": "CVE-2021-45567" }, { "db": "NVD", "id": "CVE-2021-45567" }, { "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45567" }, { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "VULMON", "id": "CVE-2021-45567" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45567", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016894", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2297", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45567", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45567" }, { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "NVD", "id": "CVE-2021-45567" }, { "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "id": "VAR-202112-2381", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:55:16.651000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0075", "trust": 0.8, "url": "https://kb.netgear.com/000064089/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0075" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177059" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "NVD", "id": "CVE-2021-45567" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064089/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0075" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45567" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45567" }, { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "NVD", "id": "CVE-2021-45567" }, { "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45567" }, { "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "db": "NVD", "id": "CVE-2021-45567" }, { "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45567" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "date": "2021-12-26T01:15:16.177000", "db": "NVD", "id": "CVE-2021-45567" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45567" }, { "date": "2022-12-26T07:42:00", "db": "JVNDB", "id": "JVNDB-2021-016894" }, { "date": "2022-01-04T19:31:37.103000", "db": "NVD", "id": "CVE-2021-45567" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2297" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2297" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016894" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2297" } ], "trust": 0.6 } }
var-202112-2353
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2353", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "NVD", "id": "CVE-2021-45596" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45596" } ] }, "cve": "CVE-2021-45596", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45596", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45596", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45596", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45596", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2396", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45596", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45596" }, { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "NVD", "id": "CVE-2021-45596" }, { "db": "NVD", "id": "CVE-2021-45596" }, { "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45596" }, { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "VULMON", "id": "CVE-2021-45596" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45596", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017081", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2396", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45596", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45596" }, { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "NVD", "id": "CVE-2021-45596" }, { "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "id": "VAR-202112-2353", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:59:56.968000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0516", "trust": 0.8, "url": "https://kb.netgear.com/000064140/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0516" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177117" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "NVD", "id": "CVE-2021-45596" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064140/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0516" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45596" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45596" }, { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "NVD", "id": "CVE-2021-45596" }, { "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45596" }, { "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "db": "NVD", "id": "CVE-2021-45596" }, { "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45596" }, { "date": "2023-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "date": "2021-12-26T01:15:17.533000", "db": "NVD", "id": "CVE-2021-45596" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45596" }, { "date": "2023-01-04T01:51:00", "db": "JVNDB", "id": "JVNDB-2021-017081" }, { "date": "2022-01-05T20:41:40.327000", "db": "NVD", "id": "CVE-2021-45596" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2396" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2396" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017081" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2396" } ], "trust": 0.6 } }
var-202006-0934
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0934", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14437" } ] }, "cve": "CVE-2020-14437", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006684", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44782", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006684", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14437", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14437", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006684", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44782", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1253", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "CNVD", "id": "CNVD-2021-44782" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14437", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006684", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44782", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1253", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" } ] }, "id": "VAR-202006-0934", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" } ] }, "last_update_date": "2023-12-18T11:58:20.493000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0054", "trust": 0.8, "url": "https://kb.netgear.com/000061940/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0054" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44782)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275021" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14437" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061940/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0054" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14437" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44782" }, { "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "db": "NVD", "id": "CVE-2020-14437" }, { "db": "CNNVD", "id": "CNNVD-202006-1253" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44782" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "date": "2020-06-18T17:15:12.860000", "db": "NVD", "id": "CVE-2020-14437" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1253" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44782" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006684" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14437" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1253" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1253" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006684" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1253" } ], "trust": 0.6 } }
var-202112-2404
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2404", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r8000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "NVD", "id": "CVE-2021-45544" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45544" } ] }, "cve": "CVE-2021-45544", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45544", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45544", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45544", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45544", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2358", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45544", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45544" }, { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "NVD", "id": "CVE-2021-45544" }, { "db": "NVD", "id": "CVE-2021-45544" }, { "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45544" }, { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "VULMON", "id": "CVE-2021-45544" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45544", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017189", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2358", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45544", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45544" }, { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "NVD", "id": "CVE-2021-45544" }, { "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "id": "VAR-202112-2404", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3106649133333334 }, "last_update_date": "2023-12-18T13:55:36.455000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0556", "trust": 0.8, "url": "https://kb.netgear.com/000064518/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0556" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176371" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "NVD", "id": "CVE-2021-45544" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064518/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0556" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45544" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45544" }, { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "NVD", "id": "CVE-2021-45544" }, { "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45544" }, { "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "db": "NVD", "id": "CVE-2021-45544" }, { "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45544" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "date": "2021-12-26T01:15:15.087000", "db": "NVD", "id": "CVE-2021-45544" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45544" }, { "date": "2023-01-06T07:18:00", "db": "JVNDB", "id": "JVNDB-2021-017189" }, { "date": "2022-01-06T16:49:36.393000", "db": "NVD", "id": "CVE-2021-45544" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2358" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2358" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017189" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2358" } ], "trust": 0.6 } }
var-202010-0573
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. NETGEAR RBK852 , RBR850 , RBS850 A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0573", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "NVD", "id": "CVE-2020-26907" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26907" } ] }, "cve": "CVE-2020-26907", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.7, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-26907", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 1.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2020-26907", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26907", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26907", "trust": 1.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202010-338", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "CNNVD", "id": "CNNVD-202010-338" }, { "db": "NVD", "id": "CVE-2020-26907" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. NETGEAR RBK852 , RBR850 , RBS850 A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state", "sources": [ { "db": "NVD", "id": "CVE-2020-26907" }, { "db": "JVNDB", "id": "JVNDB-2020-012221" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26907", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012221", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-338", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "CNNVD", "id": "CNNVD-202010-338" }, { "db": "NVD", "id": "CVE-2020-26907" } ] }, "id": "VAR-202010-0573", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T10:03:25.397000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0264", "trust": 0.8, "url": "https://kb.netgear.com/000062347/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0264" }, { "title": "Multiple NETGEAR Product Command Injection Vulnerability Fixes", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131125" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "CNNVD", "id": "CNNVD-202010-338" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "NVD", "id": "CVE-2020-26907" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062347/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0264" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26907" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "CNNVD", "id": "CNNVD-202010-338" }, { "db": "NVD", "id": "CVE-2020-26907" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "db": "CNNVD", "id": "CNNVD-202010-338" }, { "db": "NVD", "id": "CVE-2020-26907" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-338" }, { "date": "2020-10-09T07:15:00", "db": "NVD", "id": "CVE-2020-26907" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:44:00", "db": "JVNDB", "id": "JVNDB-2020-012221" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-338" }, { "date": "2020-10-16T18:46:00", "db": "NVD", "id": "CVE-2020-26907" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-338" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012221" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-338" } ], "trust": 0.6 } }
var-202006-0935
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0935", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14438" } ] }, "cve": "CVE-2020-14438", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006685", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "HIGH", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.2, "id": "CNVD-2021-44783", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14438", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006685", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14438", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14438", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006685", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44783", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1254", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14438", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14438", "trust": 3.1 }, { "db": "JVNDB", "id": "JVNDB-2020-006685", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44783", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1254", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14438", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" } ] }, "id": "VAR-202006-0935", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" } ] }, "last_update_date": "2023-12-18T13:23:12.752000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0063", "trust": 0.8, "url": "https://kb.netgear.com/000061941/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0063" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44783)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/274926" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14438" }, { "trust": 1.7, "url": "https://kb.netgear.com/000061941/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0063" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14438" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44783" }, { "db": "VULMON", "id": "CVE-2020-14438" }, { "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "db": "NVD", "id": "CVE-2020-14438" }, { "db": "CNNVD", "id": "CNNVD-202006-1254" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44783" }, { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14438" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "date": "2020-06-18T17:15:12.953000", "db": "NVD", "id": "CVE-2020-14438" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1254" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44783" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14438" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006685" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14438" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1254" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1254" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006685" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1254" } ], "trust": 0.6 } }
var-202112-2368
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2368", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "NVD", "id": "CVE-2021-45580" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45580" } ] }, "cve": "CVE-2021-45580", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45580", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45580", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45580", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45580", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2374", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45580", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45580" }, { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "NVD", "id": "CVE-2021-45580" }, { "db": "NVD", "id": "CVE-2021-45580" }, { "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45580" }, { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "VULMON", "id": "CVE-2021-45580" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45580", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016911", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2374", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45580", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45580" }, { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "NVD", "id": "CVE-2021-45580" }, { "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "id": "VAR-202112-2368", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:01:00.077000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0088", "trust": 0.8, "url": "https://kb.netgear.com/000064102/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0088" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177082" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "NVD", "id": "CVE-2021-45580" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064102/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0088" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45580" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45580" }, { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "NVD", "id": "CVE-2021-45580" }, { "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45580" }, { "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "db": "NVD", "id": "CVE-2021-45580" }, { "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45580" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "date": "2021-12-26T01:15:16.793000", "db": "NVD", "id": "CVE-2021-45580" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45580" }, { "date": "2022-12-27T01:54:00", "db": "JVNDB", "id": "JVNDB-2021-016911" }, { "date": "2022-01-04T20:39:38.540000", "db": "NVD", "id": "CVE-2021-45580" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2374" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2374" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016911" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2374" } ], "trust": 0.6 } }
var-202112-2358
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2358", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "NVD", "id": "CVE-2021-45591" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45591" } ] }, "cve": "CVE-2021-45591", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45591", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45591", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45591", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45591", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2387", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45591", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45591" }, { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "NVD", "id": "CVE-2021-45591" }, { "db": "NVD", "id": "CVE-2021-45591" }, { "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45591" }, { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "VULMON", "id": "CVE-2021-45591" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45591", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016970", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2387", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45591", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45591" }, { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "NVD", "id": "CVE-2021-45591" }, { "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "id": "VAR-202112-2358", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T14:04:08.851000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0099", "trust": 0.8, "url": "https://kb.netgear.com/000064113/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0099" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177104" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "NVD", "id": "CVE-2021-45591" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064113/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0099" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45591" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45591" }, { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "NVD", "id": "CVE-2021-45591" }, { "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45591" }, { "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "db": "NVD", "id": "CVE-2021-45591" }, { "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45591" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "date": "2021-12-26T01:15:17.300000", "db": "NVD", "id": "CVE-2021-45591" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45591" }, { "date": "2022-12-27T05:33:00", "db": "JVNDB", "id": "JVNDB-2021-016970" }, { "date": "2022-01-04T20:25:22.927000", "db": "NVD", "id": "CVE-2021-45591" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2387" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2387" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016970" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2387" } ], "trust": 0.6 } }
var-202112-2216
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2216", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "NVD", "id": "CVE-2021-45505" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45505" } ] }, "cve": "CVE-2021-45505", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45505", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45505", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45505", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45505", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2323", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45505", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45505" }, { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "NVD", "id": "CVE-2021-45505" }, { "db": "NVD", "id": "CVE-2021-45505" }, { "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45505" }, { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "VULMON", "id": "CVE-2021-45505" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45505", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017143", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2323", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45505", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45505" }, { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "NVD", "id": "CVE-2021-45505" }, { "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "id": "VAR-202112-2216", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:17:34.616000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0477", "trust": 0.8, "url": "https://kb.netgear.com/000064129/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0477" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176054" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "NVD", "id": "CVE-2021-45505" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064129/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0477" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45505" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45505" }, { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "NVD", "id": "CVE-2021-45505" }, { "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45505" }, { "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "db": "NVD", "id": "CVE-2021-45505" }, { "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45505" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "date": "2021-12-26T01:15:13.133000", "db": "NVD", "id": "CVE-2021-45505" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45505" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017143" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45505" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2323" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2323" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017143" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2323" } ], "trust": 0.6 } }
var-202103-1280
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1280", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29077" } ] }, "cve": "CVE-2021-29077", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29077", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004582", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29077", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29077", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1346", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29077", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "VULMON", "id": "CVE-2021-29077" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29077", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004582", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1346", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29077", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "id": "VAR-202103-1280", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.318865984 }, "last_update_date": "2023-12-18T11:57:29.886000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0486", "trust": 0.8, "url": "https://kb.netgear.com/000063016/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0486" }, { "title": "NETGEAR Repair measures for command injection vulnerabilities in multiple products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145162" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063016/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0486" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29077" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29077" }, { "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "db": "NVD", "id": "CVE-2021-29077" }, { "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29077" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "date": "2021-03-23T07:15:14.013000", "db": "NVD", "id": "CVE-2021-29077" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29077" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004582" }, { "date": "2021-03-24T19:34:40.230000", "db": "NVD", "id": "CVE-2021-29077" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1346" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1346" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004582" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1346" } ], "trust": 0.6 } }
var-202112-2357
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2357", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "NVD", "id": "CVE-2021-45592" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45592" } ] }, "cve": "CVE-2021-45592", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45592", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45592", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45592", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45592", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2388", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45592", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45592" }, { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "NVD", "id": "CVE-2021-45592" }, { "db": "NVD", "id": "CVE-2021-45592" }, { "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45592" }, { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "VULMON", "id": "CVE-2021-45592" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45592", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016969", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2388", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45592", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45592" }, { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "NVD", "id": "CVE-2021-45592" }, { "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "id": "VAR-202112-2357", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:51:16.249000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0100", "trust": 0.8, "url": "https://kb.netgear.com/000064114/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0100" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177106" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "NVD", "id": "CVE-2021-45592" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064114/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0100" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45592" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45592" }, { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "NVD", "id": "CVE-2021-45592" }, { "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45592" }, { "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "db": "NVD", "id": "CVE-2021-45592" }, { "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45592" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "date": "2021-12-26T01:15:17.347000", "db": "NVD", "id": "CVE-2021-45592" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45592" }, { "date": "2022-12-27T05:30:00", "db": "JVNDB", "id": "JVNDB-2021-016969" }, { "date": "2022-01-04T20:24:05.520000", "db": "NVD", "id": "CVE-2021-45592" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2388" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2388" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016969" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2388" } ], "trust": 0.6 } }
var-202112-2389
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2389", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "NVD", "id": "CVE-2021-45559" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45559" } ] }, "cve": "CVE-2021-45559", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45559", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45559", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45559", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45559", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2289", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45559", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45559" }, { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "NVD", "id": "CVE-2021-45559" }, { "db": "NVD", "id": "CVE-2021-45559" }, { "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45559" }, { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "VULMON", "id": "CVE-2021-45559" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45559", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016902", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2289", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45559", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45559" }, { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "NVD", "id": "CVE-2021-45559" }, { "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "id": "VAR-202112-2389", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:01:00.054000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0055", "trust": 0.8, "url": "https://kb.netgear.com/000064079/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0055" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177052" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "NVD", "id": "CVE-2021-45559" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064079/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0055" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45559" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45559" }, { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "NVD", "id": "CVE-2021-45559" }, { "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45559" }, { "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "db": "NVD", "id": "CVE-2021-45559" }, { "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45559" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "date": "2021-12-26T01:15:15.803000", "db": "NVD", "id": "CVE-2021-45559" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45559" }, { "date": "2022-12-26T08:45:00", "db": "JVNDB", "id": "JVNDB-2021-016902" }, { "date": "2022-01-04T20:11:45.377000", "db": "NVD", "id": "CVE-2021-45559" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2289" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2289" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016902" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2289" } ], "trust": 0.6 } }
var-202006-0585
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0585", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14427" } ] }, "cve": "CVE-2020-14427", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006748", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44774", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006748", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14427", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14427", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006748", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44774", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1240", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNVD", "id": "CNVD-2021-44774" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14427", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006748", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44774", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1240", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "id": "VAR-202006-0585", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" } ] }, "last_update_date": "2023-12-18T13:42:54.256000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0042", "trust": 0.8, "url": "https://kb.netgear.com/000061935/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0042" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44774)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275076" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121989" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14427" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061935/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0042" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14427" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44774" }, { "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "db": "NVD", "id": "CVE-2020-14427" }, { "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44774" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "date": "2020-06-18T17:15:11.920000", "db": "NVD", "id": "CVE-2020-14427" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44774" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006748" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14427" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1240" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1240" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006748" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1240" } ], "trust": 0.6 } }
var-202103-1273
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1273", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29070" } ] }, "cve": "CVE-2021-29070", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29070", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004910", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29070", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29070", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1358", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29070", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR The product contains a command injection vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "VULMON", "id": "CVE-2021-29070" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29070", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004910", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1358", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29070", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "id": "VAR-202103-1273", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2023-12-18T13:01:20.630000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0530", "trust": 0.8, "url": "https://kb.netgear.com/000063019/security-advisory-for-post-authentication-command-injection-on-some-wifi-routers-psv-2020-0530" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145680" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063019/security-advisory-for-post-authentication-command-injection-on-some-wifi-routers-psv-2020-0530" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29070" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29070" }, { "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "db": "NVD", "id": "CVE-2021-29070" }, { "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29070" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "date": "2021-03-23T07:15:13.483000", "db": "NVD", "id": "CVE-2021-29070" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29070" }, { "date": "2021-12-02T06:31:00", "db": "JVNDB", "id": "JVNDB-2021-004910" }, { "date": "2021-03-26T18:19:12.843000", "db": "NVD", "id": "CVE-2021-29070" }, { "date": "2021-03-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1358" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1358" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004910" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1358" } ], "trust": 0.6 } }
var-202112-2317
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2317", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "NVD", "id": "CVE-2021-45632" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45632" } ] }, "cve": "CVE-2021-45632", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45632", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45632", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45632", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45632", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2428", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45632", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45632" }, { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "NVD", "id": "CVE-2021-45632" }, { "db": "NVD", "id": "CVE-2021-45632" }, { "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45632" }, { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "VULMON", "id": "CVE-2021-45632" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45632", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017041", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2428", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45632", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45632" }, { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "NVD", "id": "CVE-2021-45632" }, { "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "id": "VAR-202112-2317", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:46:51.964000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0505", "trust": 0.8, "url": "https://kb.netgear.com/000064137/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0505" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176666" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "NVD", "id": "CVE-2021-45632" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064137/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0505" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45632" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45632" }, { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "NVD", "id": "CVE-2021-45632" }, { "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45632" }, { "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "db": "NVD", "id": "CVE-2021-45632" }, { "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45632" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "date": "2021-12-26T01:15:19.277000", "db": "NVD", "id": "CVE-2021-45632" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45632" }, { "date": "2022-12-28T02:47:00", "db": "JVNDB", "id": "JVNDB-2021-017041" }, { "date": "2022-01-05T18:22:28.797000", "db": "NVD", "id": "CVE-2021-45632" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2428" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2428" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017041" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2428" } ], "trust": 0.6 } }
var-202112-2337
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2337", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.74" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.68" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.46" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.126" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "NVD", "id": "CVE-2021-45612" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45612" } ] }, "cve": "CVE-2021-45612", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45612", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45612", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45612", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45612", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2408", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45612", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45612" }, { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "NVD", "id": "CVE-2021-45612" }, { "db": "NVD", "id": "CVE-2021-45612" }, { "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68", "sources": [ { "db": "NVD", "id": "CVE-2021-45612" }, { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "VULMON", "id": "CVE-2021-45612" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45612", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017558", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2408", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45612", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45612" }, { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "NVD", "id": "CVE-2021-45612" }, { "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "id": "VAR-202112-2337", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3063449172222222 }, "last_update_date": "2023-12-18T14:04:08.873000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Router,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0524", "trust": 0.8, "url": "https://kb.netgear.com/000064515/security-advisory-for-pre-authentication-command-injection-on-some-router-extenders-and-wifi-systems-psv-2020-0524" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176387" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "NVD", "id": "CVE-2021-45612" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064515/security-advisory-for-pre-authentication-command-injection-on-some-router-extenders-and-wifi-systems-psv-2020-0524" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45612" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45612" }, { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "NVD", "id": "CVE-2021-45612" }, { "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45612" }, { "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "db": "NVD", "id": "CVE-2021-45612" }, { "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45612" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "date": "2021-12-26T01:15:18.337000", "db": "NVD", "id": "CVE-2021-45612" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-07T00:00:00", "db": "VULMON", "id": "CVE-2021-45612" }, { "date": "2023-01-25T05:23:00", "db": "JVNDB", "id": "JVNDB-2021-017558" }, { "date": "2022-01-07T20:04:34.457000", "db": "NVD", "id": "CVE-2021-45612" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2408" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2408" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017558" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2408" } ], "trust": 0.6 } }
var-202010-0572
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects CBR40 prior to 2.5.0.10, RBK752 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, and RBS850 prior to 3.2.10.11
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0572", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.10.11" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26906" } ] }, "cve": "CVE-2020-26906", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-26906", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26906", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26906", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-26906", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-337", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-26906", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR The device contains a vulnerability related to insufficient protection of credentials.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects CBR40 prior to 2.5.0.10, RBK752 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, and RBS850 prior to 3.2.10.11", "sources": [ { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "VULMON", "id": "CVE-2020-26906" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26906", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-012276", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-337", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-26906", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "id": "VAR-202010-0572", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:32:53.823000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Admin\u00a0Credential\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0048", "trust": 0.8, "url": "https://kb.netgear.com/000062348/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0048" }, { "title": "Multiple NETGEAR Repair measures for device security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131124" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Inadequate protection of credentials (CWE-522) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000062348/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0048" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26906" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-26906" }, { "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "db": "NVD", "id": "CVE-2020-26906" }, { "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-10-09T00:00:00", "db": "VULMON", "id": "CVE-2020-26906" }, { "date": "2021-04-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "date": "2020-10-09T07:15:16.463000", "db": "NVD", "id": "CVE-2020-26906" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-26906" }, { "date": "2021-04-28T07:36:00", "db": "JVNDB", "id": "JVNDB-2020-012276" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26906" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-337" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-337" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Inadequate protection of credentials on devices Vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012276" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-337" } ], "trust": 0.6 } }
var-202112-2278
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX80 prior to 1.0.1.62, EX7500 prior to 1.0.0.72, R7900 prior to 1.0.4.38, R8000 prior to 1.0.4.68, RAX200 prior to 1.0.4.120, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.4.120, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.4.120, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2278", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax15", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax45", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax50", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "NVD", "id": "CVE-2021-45671" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45671" } ] }, "cve": "CVE-2021-45671", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45671", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 0.7, "impactScore": 5.3, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45671", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45671", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45671", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2465", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45671", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45671" }, { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "NVD", "id": "CVE-2021-45671" }, { "db": "NVD", "id": "CVE-2021-45671" }, { "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX80 prior to 1.0.1.62, EX7500 prior to 1.0.0.72, R7900 prior to 1.0.4.38, R8000 prior to 1.0.4.68, RAX200 prior to 1.0.4.120, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.4.120, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.4.120, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45671" }, { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "VULMON", "id": "CVE-2021-45671" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45671", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017027", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2465", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45671", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45671" }, { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "NVD", "id": "CVE-2021-45671" }, { "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "id": "VAR-202112-2278", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.26996275571428574 }, "last_update_date": "2023-12-18T13:55:39.777000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0261", "trust": 0.8, "url": "https://kb.netgear.com/000064482/security-advisory-for-stored-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0261" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=175884" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "NVD", "id": "CVE-2021-45671" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064482/security-advisory-for-stored-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0261" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45671" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45671" }, { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "NVD", "id": "CVE-2021-45671" }, { "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45671" }, { "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "db": "NVD", "id": "CVE-2021-45671" }, { "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45671" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "date": "2021-12-26T01:15:21.057000", "db": "NVD", "id": "CVE-2021-45671" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45671" }, { "date": "2022-12-28T00:05:00", "db": "JVNDB", "id": "JVNDB-2021-017027" }, { "date": "2022-01-05T21:10:11.100000", "db": "NVD", "id": "CVE-2021-45671" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2465" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2465" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017027" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2465" } ], "trust": 0.6 } }
var-202112-2373
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2373", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "NVD", "id": "CVE-2021-45575" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45575" } ] }, "cve": "CVE-2021-45575", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45575", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45575", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45575", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45575", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2286", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45575", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45575" }, { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "NVD", "id": "CVE-2021-45575" }, { "db": "NVD", "id": "CVE-2021-45575" }, { "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45575" }, { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "VULMON", "id": "CVE-2021-45575" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45575", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016893", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2286", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45575", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45575" }, { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "NVD", "id": "CVE-2021-45575" }, { "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "id": "VAR-202112-2373", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:26:30.286000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0083", "trust": 0.8, "url": "https://kb.netgear.com/000064097/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0083" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177049" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "NVD", "id": "CVE-2021-45575" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064097/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0083" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45575" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45575" }, { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "NVD", "id": "CVE-2021-45575" }, { "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45575" }, { "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "db": "NVD", "id": "CVE-2021-45575" }, { "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45575" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "date": "2021-12-26T01:15:16.553000", "db": "NVD", "id": "CVE-2021-45575" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45575" }, { "date": "2022-12-26T07:32:00", "db": "JVNDB", "id": "JVNDB-2021-016893" }, { "date": "2022-01-04T20:42:21.607000", "db": "NVD", "id": "CVE-2021-45575" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2286" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2286" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016893" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2286" } ], "trust": 0.6 } }
var-202112-2348
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2348", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45601" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45601" } ] }, "cve": "CVE-2021-45601", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45601", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "id": "CVE-2021-45601", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45601", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2397", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45601", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45601" }, { "db": "CNNVD", "id": "CNNVD-202112-2397" }, { "db": "NVD", "id": "CVE-2021-45601" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45601" }, { "db": "VULMON", "id": "CVE-2021-45601" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45601", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2397", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45601", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45601" }, { "db": "CNNVD", "id": "CNNVD-202112-2397" }, { "db": "NVD", "id": "CVE-2021-45601" } ] }, "id": "VAR-202112-2348", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T09:49:42.490000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177118" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2397" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45601" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064147/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0563" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45601" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45601" }, { "db": "CNNVD", "id": "CNNVD-202112-2397" }, { "db": "NVD", "id": "CVE-2021-45601" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45601" }, { "db": "CNNVD", "id": "CNNVD-202112-2397" }, { "db": "NVD", "id": "CVE-2021-45601" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45601" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2397" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45601" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45601" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2397" }, { "date": "2022-01-05T20:57:00", "db": "NVD", "id": "CVE-2021-45601" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2397" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2397" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2397" } ], "trust": 0.6 } }
var-202006-0937
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0937", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14440" } ] }, "cve": "CVE-2020-14440", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006681", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44785", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006681", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14440", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14440", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006681", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44785", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1259", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "CNVD", "id": "CNVD-2021-44785" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14440", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006681", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44785", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1259", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" } ] }, "id": "VAR-202006-0937", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" } ] }, "last_update_date": "2023-12-18T13:56:13.111000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0065", "trust": 0.8, "url": "https://kb.netgear.com/000061943/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0065" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44785)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275041" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14440" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061943/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0065" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14440" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44785" }, { "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "db": "NVD", "id": "CVE-2020-14440" }, { "db": "CNNVD", "id": "CNNVD-202006-1259" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44785" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "date": "2020-06-18T17:15:13.140000", "db": "NVD", "id": "CVE-2020-14440" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1259" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44785" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006681" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14440" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1259" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1259" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006681" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1259" } ], "trust": 0.6 } }
var-202112-2412
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. (DoS) It may be in a state. This affects RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2412", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax75", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "NVD", "id": "CVE-2021-45536" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45536" } ] }, "cve": "CVE-2021-45536", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45536", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45536", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45536", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45536", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2350", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45536", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45536" }, { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "NVD", "id": "CVE-2021-45536" }, { "db": "NVD", "id": "CVE-2021-45536" }, { "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. (DoS) It may be in a state. This affects RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45536" }, { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "VULMON", "id": "CVE-2021-45536" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45536", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017102", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2350", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45536", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45536" }, { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "NVD", "id": "CVE-2021-45536" }, { "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "id": "VAR-202112-2412", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:37:09.596000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0056", "trust": 0.8, "url": "https://kb.netgear.com/000064080/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0056" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176383" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "NVD", "id": "CVE-2021-45536" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064080/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0056" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45536" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45536" }, { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "NVD", "id": "CVE-2021-45536" }, { "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45536" }, { "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "db": "NVD", "id": "CVE-2021-45536" }, { "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45536" }, { "date": "2023-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "date": "2021-12-26T01:15:14.697000", "db": "NVD", "id": "CVE-2021-45536" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45536" }, { "date": "2023-01-04T06:51:00", "db": "JVNDB", "id": "JVNDB-2021-017102" }, { "date": "2022-01-05T15:40:46.863000", "db": "NVD", "id": "CVE-2021-45536" }, { "date": "2022-01-10T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2350" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2350" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command Injection Vulnerability in Command Injection Vulnerability in Devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017102" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2350" } ], "trust": 0.6 } }
var-202112-2322
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2322", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45627" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45627" } ] }, "cve": "CVE-2021-45627", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CVE-2021-45627", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "HIGH", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "id": "CVE-2021-45627", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45627", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2421", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45627", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45627" }, { "db": "CNNVD", "id": "CNNVD-202112-2421" }, { "db": "NVD", "id": "CVE-2021-45627" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45627" }, { "db": "VULMON", "id": "CVE-2021-45627" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45627", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2421", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45627", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45627" }, { "db": "CNNVD", "id": "CNNVD-202112-2421" }, { "db": "NVD", "id": "CVE-2021-45627" } ] }, "id": "VAR-202112-2322", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T10:07:01.094000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177129" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2421" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45627" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064124/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0471" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45627" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45627" }, { "db": "CNNVD", "id": "CNNVD-202112-2421" }, { "db": "NVD", "id": "CVE-2021-45627" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45627" }, { "db": "CNNVD", "id": "CNNVD-202112-2421" }, { "db": "NVD", "id": "CVE-2021-45627" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45627" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2421" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45627" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45627" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2421" }, { "date": "2022-01-04T20:54:00", "db": "NVD", "id": "CVE-2021-45627" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2421" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2421" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2421" } ], "trust": 0.6 } }
var-202103-1267
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR The device contains a vulnerability related to information leakage.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.1.4, RBS40V prior to 2.6.1.4, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBK754 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBK854 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1267", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29082" } ] }, "cve": "CVE-2021-29082", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29082", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "LOW", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.3, "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "Low", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-29082", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29082", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29082", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1341", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29082", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR The device contains a vulnerability related to information leakage.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.1.4, RBS40V prior to 2.6.1.4, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBK754 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBK854 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "VULMON", "id": "CVE-2021-29082" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29082", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004587", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1341", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29082", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "id": "VAR-202103-1267", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.318865984 }, "last_update_date": "2023-12-18T13:22:57.460000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0037", "trust": 0.8, "url": "https://kb.netgear.com/000063005/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0037" }, { "title": "NETGEAR Repair measures for information disclosure vulnerabilities of various products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145157" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063005/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0037" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29082" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/200.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29082" }, { "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "db": "NVD", "id": "CVE-2021-29082" }, { "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29082" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "date": "2021-03-23T07:15:14.390000", "db": "NVD", "id": "CVE-2021-29082" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29082" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004587" }, { "date": "2022-06-28T14:11:45.273000", "db": "NVD", "id": "CVE-2021-29082" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1341" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1341" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Information leakage vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004587" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1341" } ], "trust": 0.6 } }
var-202112-2321
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 3.2.18.2, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBS40V prior to 2.6.2.4, and RBW30 prior to 2.6.2.2
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2321", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.18.2" }, { "model": "rbs40v", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "NVD", "id": "CVE-2021-45628" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.4", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:2.6.2.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45628" } ] }, "cve": "CVE-2021-45628", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45628", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45628", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45628", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45628", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2424", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45628", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45628" }, { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "NVD", "id": "CVE-2021-45628" }, { "db": "NVD", "id": "CVE-2021-45628" }, { "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 3.2.18.2, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBS40V prior to 2.6.2.4, and RBW30 prior to 2.6.2.2", "sources": [ { "db": "NVD", "id": "CVE-2021-45628" }, { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "VULMON", "id": "CVE-2021-45628" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45628", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017047", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2424", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45628", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45628" }, { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "NVD", "id": "CVE-2021-45628" }, { "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "id": "VAR-202112-2321", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.16585818000000002 }, "last_update_date": "2023-12-18T11:56:47.630000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0472", "trust": 0.8, "url": "https://kb.netgear.com/000064125/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0472" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176403" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "NVD", "id": "CVE-2021-45628" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064125/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0472" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45628" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45628" }, { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "NVD", "id": "CVE-2021-45628" }, { "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45628" }, { "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "db": "NVD", "id": "CVE-2021-45628" }, { "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45628" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "date": "2021-12-26T01:15:19.097000", "db": "NVD", "id": "CVE-2021-45628" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45628" }, { "date": "2022-12-28T03:06:00", "db": "JVNDB", "id": "JVNDB-2021-017047" }, { "date": "2022-01-05T18:20:40.293000", "db": "NVD", "id": "CVE-2021-45628" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2424" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2424" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017047" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2424" } ], "trust": 0.6 } }
var-202112-2349
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2349", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45600" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45600" } ] }, "cve": "CVE-2021-45600", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CVE-2021-45600", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 1.1, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.2, "id": "CVE-2021-45600", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45600", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2395", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45600", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45600" }, { "db": "CNNVD", "id": "CNNVD-202112-2395" }, { "db": "NVD", "id": "CVE-2021-45600" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. This affects CBR750 prior to 4.6.3.6, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45600" }, { "db": "VULMON", "id": "CVE-2021-45600" } ], "trust": 0.99 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45600", "trust": 1.7 }, { "db": "CNNVD", "id": "CNNVD-202112-2395", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45600", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45600" }, { "db": "CNNVD", "id": "CNNVD-202112-2395" }, { "db": "NVD", "id": "CVE-2021-45600" } ] }, "id": "VAR-202112-2349", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.22985245333333335 }, "last_update_date": "2022-05-04T08:51:47.602000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177116" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2395" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45600" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064146/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0555" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45600" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45600" }, { "db": "CNNVD", "id": "CNNVD-202112-2395" }, { "db": "NVD", "id": "CVE-2021-45600" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45600" }, { "db": "CNNVD", "id": "CNNVD-202112-2395" }, { "db": "NVD", "id": "CVE-2021-45600" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45600" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2395" }, { "date": "2021-12-26T01:15:00", "db": "NVD", "id": "CVE-2021-45600" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45600" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2395" }, { "date": "2022-01-04T20:50:00", "db": "NVD", "id": "CVE-2021-45600" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2395" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Netgear NETGEAR Command injection vulnerability", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2395" } ], "trust": 0.6 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2395" } ], "trust": 0.6 } }
var-202112-2388
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2388", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "NVD", "id": "CVE-2021-45560" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45560" } ] }, "cve": "CVE-2021-45560", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45560", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45560", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45560", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45560", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2288", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45560", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45560" }, { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "NVD", "id": "CVE-2021-45560" }, { "db": "NVD", "id": "CVE-2021-45560" }, { "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45560" }, { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "VULMON", "id": "CVE-2021-45560" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45560", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016903", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2288", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45560", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45560" }, { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "NVD", "id": "CVE-2021-45560" }, { "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "id": "VAR-202112-2388", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:06:53.533000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0057", "trust": 0.8, "url": "https://kb.netgear.com/000064081/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0057" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177051" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "NVD", "id": "CVE-2021-45560" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064081/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0057" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45560" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45560" }, { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "NVD", "id": "CVE-2021-45560" }, { "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45560" }, { "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "db": "NVD", "id": "CVE-2021-45560" }, { "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45560" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "date": "2021-12-26T01:15:15.847000", "db": "NVD", "id": "CVE-2021-45560" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45560" }, { "date": "2022-12-26T08:48:00", "db": "JVNDB", "id": "JVNDB-2021-016903" }, { "date": "2022-01-04T20:11:16.060000", "db": "NVD", "id": "CVE-2021-45560" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2288" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2288" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016903" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2288" } ], "trust": 0.6 } }
var-202112-2421
Vulnerability from variot
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D6220 prior to 1.0.0.68, D6400 prior to 1.0.0.102, D7000v2 prior to 1.0.0.66, D8500 prior to 1.0.3.58, DC112A prior to 1.0.0.54, EX7000 prior to 1.0.1.94, EX7500 prior to 1.0.0.72, R6250 prior to 1.0.4.48, R6300v2 prior to 1.0.4.52, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.102, R6700v3 prior to 1.0.4.102, R7000 prior to 1.0.11.116, R7100LG prior to 1.0.0.64, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.30, R7960P prior to 1.4.1.68, R8000 prior to 1.0.4.52, RAX200 prior to 1.0.2.88, RBS40V prior to 2.6.2.4, RS400 prior to 1.5.1.80, XR300 prior to 1.0.3.56, R7000P prior to 1.3.2.124, R8000P prior to 1.4.1.68, R8500 prior to 1.0.2.144, RAX80 prior to 1.0.3.102, R6900P prior to 1.3.2.124, R7900P prior to 1.4.1.68, R8300 prior to 1.0.2.144, RAX75 prior to 1.0.3.102, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2421", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.58" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.102" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.30" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.68" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.88" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "r8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.68" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "r8300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.144" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.68" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.52" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.102" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "r6300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.52" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.48" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.56" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.94" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.68" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.54" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.102" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d8500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6220", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "NVD", "id": "CVE-2021-45527" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.30", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45527" } ] }, "cve": "CVE-2021-45527", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45527", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45527", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45527", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45527", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2341", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "NVD", "id": "CVE-2021-45527" }, { "db": "NVD", "id": "CVE-2021-45527" }, { "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR A classic buffer overflow vulnerability exists on the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects D6220 prior to 1.0.0.68, D6400 prior to 1.0.0.102, D7000v2 prior to 1.0.0.66, D8500 prior to 1.0.3.58, DC112A prior to 1.0.0.54, EX7000 prior to 1.0.1.94, EX7500 prior to 1.0.0.72, R6250 prior to 1.0.4.48, R6300v2 prior to 1.0.4.52, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.102, R6700v3 prior to 1.0.4.102, R7000 prior to 1.0.11.116, R7100LG prior to 1.0.0.64, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.30, R7960P prior to 1.4.1.68, R8000 prior to 1.0.4.52, RAX200 prior to 1.0.2.88, RBS40V prior to 2.6.2.4, RS400 prior to 1.5.1.80, XR300 prior to 1.0.3.56, R7000P prior to 1.3.2.124, R8000P prior to 1.4.1.68, R8500 prior to 1.0.2.144, RAX80 prior to 1.0.3.102, R6900P prior to 1.3.2.124, R7900P prior to 1.4.1.68, R8300 prior to 1.0.2.144, RAX75 prior to 1.0.3.102, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45527" }, { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "VULMON", "id": "CVE-2021-45527" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45527", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017285", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2341", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45527", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45527" }, { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "NVD", "id": "CVE-2021-45527" }, { "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "id": "VAR-202112-2421", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3803990326086956 }, "last_update_date": "2023-12-18T13:42:20.002000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0437", "trust": 0.8, "url": "https://kb.netgear.com/000064493/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-extenders-and-wifi-systems-psv-2020-0437" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177093" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-120", "trust": 1.0 }, { "problemtype": "Classic buffer overflow (CWE-120) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "NVD", "id": "CVE-2021-45527" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064493/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-extenders-and-wifi-systems-psv-2020-0437" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45527" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45527" }, { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "NVD", "id": "CVE-2021-45527" }, { "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45527" }, { "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "db": "NVD", "id": "CVE-2021-45527" }, { "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45527" }, { "date": "2023-01-13T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "date": "2021-12-26T01:15:14.207000", "db": "NVD", "id": "CVE-2021-45527" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45527" }, { "date": "2023-01-13T05:03:00", "db": "JVNDB", "id": "JVNDB-2021-017285" }, { "date": "2022-01-10T15:07:55.177000", "db": "NVD", "id": "CVE-2021-45527" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2341" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2341" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017285" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2341" } ], "trust": 0.6 } }
var-202006-0587
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. This affects MK62 prior to 1.0.4.92, MK63 prior to 1.0.4.92, MR60 prior to 1.0.4.92, MS60 prior to 1.0.4.92, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0587", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "mk63", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "mk62", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "mk63", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "mr60", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "ms60", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "1.0.4.92" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk63_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk63:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14429" } ] }, "cve": "CVE-2020-14429", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006746", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "VULMON", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CVE-2020-14429", "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "MEDIUM", "trust": 0.1, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006746", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14429", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14429", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006746", "trust": 0.8, "value": "High" }, { "author": "CNNVD", "id": "CNNVD-202006-1243", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2020-14429", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. This affects MK62 prior to 1.0.4.92, MK63 prior to 1.0.4.92, MR60 prior to 1.0.4.92, MS60 prior to 1.0.4.92, RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "VULMON", "id": "CVE-2020-14429" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14429", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2020-006746", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202006-1243", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2020-14429", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "id": "VAR-202006-0587", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.37514237899999997 }, "last_update_date": "2024-02-13T22:58:46.794000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0050", "trust": 0.8, "url": "https://kb.netgear.com/000061938/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0050" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121991" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000061938/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0050" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14429" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14429" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2020-14429" }, { "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "db": "NVD", "id": "CVE-2020-14429" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-18T00:00:00", "db": "VULMON", "id": "CVE-2020-14429" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "date": "2020-06-18T17:15:12.077000", "db": "NVD", "id": "CVE-2020-14429" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2020-14429" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006746" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1243" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14429" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1243" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006746" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1243" } ], "trust": 0.6 } }
var-202112-1861
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-1861", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "NVD", "id": "CVE-2021-45584" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45584" } ] }, "cve": "CVE-2021-45584", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45584", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-016677", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45584", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45584", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2380", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45584", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45584" }, { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "NVD", "id": "CVE-2021-45584" }, { "db": "NVD", "id": "CVE-2021-45584" }, { "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45584" }, { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "VULMON", "id": "CVE-2021-45584" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45584", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016677", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2380", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45584", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45584" }, { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "NVD", "id": "CVE-2021-45584" }, { "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "id": "VAR-202112-1861", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:06:57.508000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0092", "trust": 0.8, "url": "https://kb.netgear.com/000064106/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0092" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176665" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "NVD", "id": "CVE-2021-45584" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064106/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0092" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45584" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45584" }, { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "NVD", "id": "CVE-2021-45584" }, { "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45584" }, { "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "db": "NVD", "id": "CVE-2021-45584" }, { "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45584" }, { "date": "2022-12-21T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "date": "2021-12-26T01:15:16.977000", "db": "NVD", "id": "CVE-2021-45584" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-30T00:00:00", "db": "VULMON", "id": "CVE-2021-45584" }, { "date": "2022-12-21T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-016677" }, { "date": "2021-12-30T14:55:43.303000", "db": "NVD", "id": "CVE-2021-45584" }, { "date": "2021-12-31T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2380" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2380" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016677" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2380" } ], "trust": 0.6 } }
var-202103-1275
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1275", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29072" } ] }, "cve": "CVE-2021-29072", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29072", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004578", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29072", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29072", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1354", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29072", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "VULMON", "id": "CVE-2021-29072" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29072", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004578", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1354", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29072", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "id": "VAR-202103-1275", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3648863 }, "last_update_date": "2023-12-18T13:12:34.713000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0493", "trust": 0.8, "url": "https://kb.netgear.com/000063018/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0493" }, { "title": "Certain NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=144972" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063018/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0493" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29072" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29072" }, { "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "db": "NVD", "id": "CVE-2021-29072" }, { "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29072" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "date": "2021-03-23T07:15:13.640000", "db": "NVD", "id": "CVE-2021-29072" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29072" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004578" }, { "date": "2021-03-24T20:20:00.353000", "db": "NVD", "id": "CVE-2021-29072" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1354" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1354" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004578" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1354" } ], "trust": 0.6 } }
var-202112-2380
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2380", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "NVD", "id": "CVE-2021-45568" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45568" } ] }, "cve": "CVE-2021-45568", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45568", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45568", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45568", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45568", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2295", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45568", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45568" }, { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "NVD", "id": "CVE-2021-45568" }, { "db": "NVD", "id": "CVE-2021-45568" }, { "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45568" }, { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "VULMON", "id": "CVE-2021-45568" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45568", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016895", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2295", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45568", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45568" }, { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "NVD", "id": "CVE-2021-45568" }, { "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "id": "VAR-202112-2380", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:46:51.887000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0076", "trust": 0.8, "url": "https://kb.netgear.com/000064090/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0076" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177057" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "NVD", "id": "CVE-2021-45568" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064090/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0076" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45568" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45568" }, { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "NVD", "id": "CVE-2021-45568" }, { "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45568" }, { "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "db": "NVD", "id": "CVE-2021-45568" }, { "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45568" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "date": "2021-12-26T01:15:16.220000", "db": "NVD", "id": "CVE-2021-45568" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45568" }, { "date": "2022-12-26T07:46:00", "db": "JVNDB", "id": "JVNDB-2021-016895" }, { "date": "2022-01-04T19:31:04.083000", "db": "NVD", "id": "CVE-2021-45568" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2295" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2295" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016895" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2295" } ], "trust": 0.6 } }
var-202112-2362
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2362", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "NVD", "id": "CVE-2021-45587" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45587" } ] }, "cve": "CVE-2021-45587", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45587", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45587", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45587", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45587", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2386", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45587", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45587" }, { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "NVD", "id": "CVE-2021-45587" }, { "db": "NVD", "id": "CVE-2021-45587" }, { "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45587" }, { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "VULMON", "id": "CVE-2021-45587" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45587", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016909", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2386", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45587", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45587" }, { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "NVD", "id": "CVE-2021-45587" }, { "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "id": "VAR-202112-2362", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:55:36.501000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0095", "trust": 0.8, "url": "https://kb.netgear.com/000064109/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0095" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177102" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "NVD", "id": "CVE-2021-45587" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064109/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0095" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45587" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45587" }, { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "NVD", "id": "CVE-2021-45587" }, { "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45587" }, { "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "db": "NVD", "id": "CVE-2021-45587" }, { "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45587" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "date": "2021-12-26T01:15:17.117000", "db": "NVD", "id": "CVE-2021-45587" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45587" }, { "date": "2022-12-27T01:41:00", "db": "JVNDB", "id": "JVNDB-2021-016909" }, { "date": "2022-01-04T20:31:17.723000", "db": "NVD", "id": "CVE-2021-45587" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2386" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2386" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016909" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2386" } ], "trust": 0.6 } }
var-202103-1286
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1286", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.4" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29067" } ] }, "cve": "CVE-2021-29067", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 6.5, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 8.3, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-29067", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.6, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004913", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29067", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-29067", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202103-1361", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-29067", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The product contains an authentication vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBS40V prior to 2.6.2.4, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "VULMON", "id": "CVE-2021-29067" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29067", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004913", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1361", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29067", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "id": "VAR-202103-1286", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.318865984 }, "last_update_date": "2023-12-18T12:16:30.158000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0492", "trust": 0.8, "url": "https://kb.netgear.com/000063017/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0492" }, { "title": "Netgear NETGEAR Remediation measures for authorization problem vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145682" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063017/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0492" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29067" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29067" }, { "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "db": "NVD", "id": "CVE-2021-29067" }, { "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29067" }, { "date": "2021-12-02T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "date": "2021-03-23T07:15:13.233000", "db": "NVD", "id": "CVE-2021-29067" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-26T00:00:00", "db": "VULMON", "id": "CVE-2021-29067" }, { "date": "2021-12-02T07:19:00", "db": "JVNDB", "id": "JVNDB-2021-004913" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-29067" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1361" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1361" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Product authentication vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004913" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1361" } ], "trust": 0.6 } }
var-202112-2318
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2318", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "NVD", "id": "CVE-2021-45631" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45631" } ] }, "cve": "CVE-2021-45631", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45631", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45631", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45631", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45631", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2427", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45631", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45631" }, { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "NVD", "id": "CVE-2021-45631" }, { "db": "NVD", "id": "CVE-2021-45631" }, { "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45631" }, { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "VULMON", "id": "CVE-2021-45631" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45631", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017042", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2427", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45631", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45631" }, { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "NVD", "id": "CVE-2021-45631" }, { "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "id": "VAR-202112-2318", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:55:16.721000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0504", "trust": 0.8, "url": "https://kb.netgear.com/000064136/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0504" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176406" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "NVD", "id": "CVE-2021-45631" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064136/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0504" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45631" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45631" }, { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "NVD", "id": "CVE-2021-45631" }, { "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45631" }, { "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "db": "NVD", "id": "CVE-2021-45631" }, { "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45631" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "date": "2021-12-26T01:15:19.233000", "db": "NVD", "id": "CVE-2021-45631" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45631" }, { "date": "2022-12-28T02:52:00", "db": "JVNDB", "id": "JVNDB-2021-017042" }, { "date": "2022-01-05T18:21:49.057000", "db": "NVD", "id": "CVE-2021-45631" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2427" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2427" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017042" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2427" } ], "trust": 0.6 } }
var-202103-1266
Vulnerability from variot
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1266", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk854", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk754", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk753s", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk853", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.2.2" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753s", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk853", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk854", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk753", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk754", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-29081" } ] }, "cve": "CVE-2021-29081", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-29081", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 8.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-004586", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-29081", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-29081", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202103-1342", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-29081", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "VULMON", "id": "CVE-2021-29081" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-29081", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2021-004586", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202103-1342", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-29081", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "id": "VAR-202103-1266", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.318865984 }, "last_update_date": "2023-12-18T12:55:37.841000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0465", "trust": 0.8, "url": "https://kb.netgear.com/000063012/security-advisory-for-pre-authentication-stack-overflow-on-some-wifi-systems-psv-2020-0465" }, { "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=145158" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000063012/security-advisory-for-pre-authentication-stack-overflow-on-some-wifi-systems-psv-2020-0465" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29081" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-29081" }, { "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "db": "NVD", "id": "CVE-2021-29081" }, { "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-23T00:00:00", "db": "VULMON", "id": "CVE-2021-29081" }, { "date": "2021-11-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "date": "2021-03-23T07:15:14.310000", "db": "NVD", "id": "CVE-2021-29081" }, { "date": "2021-03-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-03-24T00:00:00", "db": "VULMON", "id": "CVE-2021-29081" }, { "date": "2021-11-25T03:10:00", "db": "JVNDB", "id": "JVNDB-2021-004586" }, { "date": "2021-03-24T19:15:48.220000", "db": "NVD", "id": "CVE-2021-29081" }, { "date": "2021-08-16T00:00:00", "db": "CNNVD", "id": "CNNVD-202103-1342" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1342" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-004586" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202103-1342" } ], "trust": 0.6 } }
var-202112-2319
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2319", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "NVD", "id": "CVE-2021-45630" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45630" } ] }, "cve": "CVE-2021-45630", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45630", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45630", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45630", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45630", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2426", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45630", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45630" }, { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "NVD", "id": "CVE-2021-45630" }, { "db": "NVD", "id": "CVE-2021-45630" }, { "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45630" }, { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "VULMON", "id": "CVE-2021-45630" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45630", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017044", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2426", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45630", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45630" }, { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "NVD", "id": "CVE-2021-45630" }, { "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "id": "VAR-202112-2319", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:32:23.611000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0498", "trust": 0.8, "url": "https://kb.netgear.com/000064135/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0498" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176405" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "NVD", "id": "CVE-2021-45630" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064135/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0498" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45630" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45630" }, { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "NVD", "id": "CVE-2021-45630" }, { "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45630" }, { "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "db": "NVD", "id": "CVE-2021-45630" }, { "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45630" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "date": "2021-12-26T01:15:19.187000", "db": "NVD", "id": "CVE-2021-45630" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45630" }, { "date": "2022-12-28T02:57:00", "db": "JVNDB", "id": "JVNDB-2021-017044" }, { "date": "2022-01-05T18:21:29.863000", "db": "NVD", "id": "CVE-2021-45630" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2426" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2426" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017044" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2426" } ], "trust": 0.6 } }
var-202012-1175
Vulnerability from variot
plural NETGEAR An unspecified vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state.
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1175", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "d6000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.80" }, { "model": "ex7300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "ex3110", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "rbr20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.36" }, { "model": "rbr50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "cbk40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "r7400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "ex7300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.152" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "d7000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.62" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rbs20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "dc112a", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.60" }, { "model": "rbs840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "wn3500rpv1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.28" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "rbs40v-200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "r6700v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "ex6150v1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.46" }, { "model": "r7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.74" }, { "model": "xr700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.34" }, { "model": "ex6110", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "rax35", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.80" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.134" }, { "model": "r6300v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.42" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.106" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "r6900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "rbk20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "rax120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.136" }, { "model": "d6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.94" }, { "model": "r6260", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "xr450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "ex8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.224" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.98" }, { "model": "wnr2000v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.12" }, { "model": "ex6150v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.94" }, { "model": "ex2700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.58" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "ex7700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.210" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "dm200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.66" }, { "model": "rbs50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.62" }, { "model": "ex6100v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.94" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "wndr3400v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.32" }, { "model": "ac2400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r7450", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.26" }, { "model": "rbr10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "rbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "wn3000rpv3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.86" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.84" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "r6230", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "r6800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.124" }, { "model": "d8500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.0.48" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "rbs50y", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "r7350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "ex6200v1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.94" }, { "model": "r6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.100" }, { "model": "r8300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.134" }, { "model": "r6400v1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.62" }, { "model": "ex7320", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.102" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.36" }, { "model": "r6330", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "ex6410", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "ac2100", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.84" }, { "model": "d7800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.48" }, { "model": "r6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.70" }, { "model": "r7500v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.48" }, { "model": "r6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.42" }, { "model": "r6850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.1.6" }, { "model": "rax40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.80" }, { "model": "rbk50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.40" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.68" }, { "model": "ex6250", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "wnr1000v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.78" }, { "model": "r8900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbr840", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.102" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.4" }, { "model": "ex6000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "rbk842", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.54" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.58" }, { "model": "r9000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "rbs10", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r7100lg", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.56" }, { "model": "rbs40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.38" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.24" }, { "model": "ac2600", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r7200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.50" }, { "model": "ex6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.152" }, { "model": "ex6920", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.54" }, { "model": "d6220", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.60" }, { "model": "ex7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.90" }, { "model": "dgn2200v4", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.114" }, { "model": "ex3920", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.84" }, { "model": "ex6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.128" }, { "model": "wn2500rpv2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.56" }, { "model": "r6350", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.0.76" }, { "model": "xr500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.3.2.66" }, { "model": "r6900v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.2.0.72" }, { "model": "rbk12", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.44" }, { "model": "r6700v1", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.16" }, { "model": "d6000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ac2600", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7000v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ac2400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6220", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d7800", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ac2100", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbk40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "d6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "NVD", "id": "CVE-2020-35800" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbk40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dgn2200v4_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.114", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dgn2200v4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3110_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3110:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3920_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3920:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6100v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6100v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6110_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6110:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6150v1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6150v1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6150v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6150v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6200v1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.94", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6200v1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.152", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6920_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6920:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.152", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7300v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7300v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.210", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.224", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6330:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk12:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs10:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.1.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v-200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v-200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wn2500rpv2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wn2500rpv2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.86", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wn3500rpv1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wn3500rpv1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wndr3400v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wndr3400v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr1000v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr1000v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:wnr2000v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:wnr2000v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-35800" } ] }, "cve": "CVE-2020-35800", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 9.7, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 9.5, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 9.7, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2020-35800", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "LOW", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.5, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "Low", "baseScore": 9.4, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-015016", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-35800", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2020-35800", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202012-1740", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "NVD", "id": "CVE-2020-35800" }, { "db": "NVD", "id": "CVE-2020-35800" }, { "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR An unspecified vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state.", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" } ], "trust": 0.8 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-35800", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-015016", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202012-1740", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "NVD", "id": "CVE-2020-35800" }, { "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "id": "VAR-202012-1175", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.40763064986486497 }, "last_update_date": "2023-12-18T12:27:05.432000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Security\u00a0Misconfiguration\u00a0on\u00a0Some\u00a0Routers,\u00a0Range\u00a0Extenders,\u00a0and\u00a0Orbi\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0112", "trust": 0.8, "url": "https://kb.netgear.com/000062733/security-advisory-for-security-misconfiguration-on-some-routers-range-extenders-and-orbi-wifi-systems-psv-2020-0112" }, { "title": "Certain NETGEAR devices Repair measures for default configuration problems", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=138265" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "NVD", "id": "CVE-2020-35800" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062733/security-advisory-for-security-misconfiguration-on-some-routers-range-extenders-and-orbi-wifi-systems-psv-2020-0112" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35800" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "NVD", "id": "CVE-2020-35800" }, { "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "db": "NVD", "id": "CVE-2020-35800" }, { "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "date": "2020-12-30T00:15:14.410000", "db": "NVD", "id": "CVE-2020-35800" }, { "date": "2020-12-29T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-07T09:06:00", "db": "JVNDB", "id": "JVNDB-2020-015016" }, { "date": "2021-01-04T14:55:12.933000", "db": "NVD", "id": "CVE-2020-35800" }, { "date": "2021-01-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202012-1740" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1740" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-015016" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Default configuration problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202012-1740" } ], "trust": 0.6 } }
var-202112-2371
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2371", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "NVD", "id": "CVE-2021-45577" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45577" } ] }, "cve": "CVE-2021-45577", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45577", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45577", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45577", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45577", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2378", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45577", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45577" }, { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "NVD", "id": "CVE-2021-45577" }, { "db": "NVD", "id": "CVE-2021-45577" }, { "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45577" }, { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "VULMON", "id": "CVE-2021-45577" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45577", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016887", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2378", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45577", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45577" }, { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "NVD", "id": "CVE-2021-45577" }, { "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "id": "VAR-202112-2371", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:48:55.651000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0085", "trust": 0.8, "url": "https://kb.netgear.com/000064099/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0085" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177088" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "NVD", "id": "CVE-2021-45577" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064099/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0085" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45577" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45577" }, { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "NVD", "id": "CVE-2021-45577" }, { "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45577" }, { "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "db": "NVD", "id": "CVE-2021-45577" }, { "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45577" }, { "date": "2022-12-26T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "date": "2021-12-26T01:15:16.650000", "db": "NVD", "id": "CVE-2021-45577" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45577" }, { "date": "2022-12-26T06:04:00", "db": "JVNDB", "id": "JVNDB-2021-016887" }, { "date": "2022-01-04T20:41:25.223000", "db": "NVD", "id": "CVE-2021-45577" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2378" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2378" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016887" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2378" } ], "trust": 0.6 } }
var-202006-0588
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.
There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0588", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14430" } ] }, "cve": "CVE-2020-14430", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006742", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44775", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "LOW", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006742", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14430", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14430", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006742", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44775", "trust": 0.6, "value": "LOW" }, { "author": "CNNVD", "id": "CNNVD-202006-1244", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials", "sources": [ { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNVD", "id": "CNVD-2021-44775" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14430", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006742", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44775", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1244", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "id": "VAR-202006-0588", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" } ] }, "last_update_date": "2023-12-18T12:27:27.688000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0051", "trust": 0.8, "url": "https://kb.netgear.com/000061939/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0051" }, { "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44775)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275111" }, { "title": "Multiple NETGEAR Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121992" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "CWE-522", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14430" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061939/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0051" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14430" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44775" }, { "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "db": "NVD", "id": "CVE-2020-14430" }, { "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44775" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "date": "2020-06-18T17:15:12.170000", "db": "NVD", "id": "CVE-2020-14430" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-07-04T00:00:00", "db": "CNVD", "id": "CNVD-2021-44775" }, { "date": "2020-07-16T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006742" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14430" }, { "date": "2020-06-22T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1244" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1244" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Inadequate protection of credentials on devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006742" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1244" } ], "trust": 0.6 } }
var-202112-2320
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2320", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "NVD", "id": "CVE-2021-45629" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45629" } ] }, "cve": "CVE-2021-45629", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45629", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45629", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45629", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45629", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2425", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45629", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45629" }, { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "NVD", "id": "CVE-2021-45629" }, { "db": "NVD", "id": "CVE-2021-45629" }, { "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45629" }, { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "VULMON", "id": "CVE-2021-45629" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45629", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017045", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2425", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45629", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45629" }, { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "NVD", "id": "CVE-2021-45629" }, { "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "id": "VAR-202112-2320", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:55:36.546000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0488", "trust": 0.8, "url": "https://kb.netgear.com/000064132/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0488" }, { "title": "NETGEAR Repair measures for device security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176404" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "NVD", "id": "CVE-2021-45629" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064132/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0488" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45629" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45629" }, { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "NVD", "id": "CVE-2021-45629" }, { "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45629" }, { "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "db": "NVD", "id": "CVE-2021-45629" }, { "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45629" }, { "date": "2022-12-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "date": "2021-12-26T01:15:19.143000", "db": "NVD", "id": "CVE-2021-45629" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45629" }, { "date": "2022-12-28T03:02:00", "db": "JVNDB", "id": "JVNDB-2021-017045" }, { "date": "2022-01-05T18:21:01.007000", "db": "NVD", "id": "CVE-2021-45629" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2425" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2425" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017045" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2425" } ], "trust": 0.6 } }
var-202010-0567
Vulnerability from variot
Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0567", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "NVD", "id": "CVE-2020-26901" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-26901" } ] }, "cve": "CVE-2020-26901", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.3, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2020-26901", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2020-26901", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-26901", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2020-26901", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202010-331", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "NVD", "id": "CVE-2020-26901" }, { "db": "NVD", "id": "CVE-2020-26901" }, { "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25", "sources": [ { "db": "NVD", "id": "CVE-2020-26901" }, { "db": "JVNDB", "id": "JVNDB-2020-012227" } ], "trust": 1.62 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-26901", "trust": 2.4 }, { "db": "JVNDB", "id": "JVNDB-2020-012227", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202010-331", "trust": 0.6 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "NVD", "id": "CVE-2020-26901" }, { "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "id": "VAR-202010-0567", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T14:04:34.033000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0036", "trust": 0.8, "url": "https://kb.netgear.com/000062353/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0036" }, { "title": "Multiple NETGEAR Repair measures for device information disclosure vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=131120" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "NVD", "id": "CVE-2020-26901" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://kb.netgear.com/000062353/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0036" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26901" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "NVD", "id": "CVE-2020-26901" }, { "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "db": "NVD", "id": "CVE-2020-26901" }, { "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "date": "2020-10-09T07:15:14.730000", "db": "NVD", "id": "CVE-2020-26901" }, { "date": "2020-10-09T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-04-27T05:46:00", "db": "JVNDB", "id": "JVNDB-2020-012227" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-26901" }, { "date": "2020-10-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202010-331" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-331" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Information leakage vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-012227" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-202010-331" } ], "trust": 0.6 } }
var-202112-2327
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.116, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2327", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "xr1000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "lax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.1.6.28" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rax35v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.68" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.70" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.118" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.74" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.68" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "rax43", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.3.140" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "r7850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.5.68" }, { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.58" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rax40v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.96" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.116" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400v2", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mr60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "lax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ms60", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "mk62", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "NVD", "id": "CVE-2021-45622" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45622" } ] }, "cve": "CVE-2021-45622", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45622", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45622", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45622", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45622", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2418", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "NVD", "id": "CVE-2021-45622" }, { "db": "NVD", "id": "CVE-2021-45622" }, { "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.116, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68", "sources": [ { "db": "NVD", "id": "CVE-2021-45622" }, { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "VULMON", "id": "CVE-2021-45622" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45622", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017541", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2418", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45622", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45622" }, { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "NVD", "id": "CVE-2021-45622" }, { "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "id": "VAR-202112-2327", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3107383099999999 }, "last_update_date": "2023-12-18T12:16:02.210000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0506", "trust": 0.8, "url": "https://kb.netgear.com/000064499/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0506" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176397" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "NVD", "id": "CVE-2021-45622" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064509/security-advisory-for-pre-authentication-command-injection-on-some-routers-extender-wifi-systems-psv-2020-0506" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45622" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45622" }, { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "NVD", "id": "CVE-2021-45622" }, { "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45622" }, { "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "db": "NVD", "id": "CVE-2021-45622" }, { "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45622" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "date": "2021-12-26T01:15:18.810000", "db": "NVD", "id": "CVE-2021-45622" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45622" }, { "date": "2023-01-25T02:01:00", "db": "JVNDB", "id": "JVNDB-2021-017541" }, { "date": "2022-01-10T15:54:09.950000", "db": "NVD", "id": "CVE-2021-45622" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2418" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2418" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017541" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2418" } ], "trust": 0.6 } }
var-202112-2405
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R8000 before 1.0.4.74, RAX200 before 1.0.4.120, R8000P before 1.4.2.84, R7900P before 1.4.2.84, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R8000 prior to 1.0.4.74, RAX200 prior to 1.0.4.120, R8000P prior to 1.4.2.84, R7900P prior to 1.4.2.84, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2405", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.120" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.74" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "r7900p", "scope": "eq", "trust": 1.0, "vendor": "netgear", "version": "1.4.2.84" }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r8000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "NVD", "id": "CVE-2021-45543" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:1.4.2.84:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45543" } ] }, "cve": "CVE-2021-45543", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45543", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45543", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45543", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45543", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2357", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45543", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45543" }, { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "NVD", "id": "CVE-2021-45543" }, { "db": "NVD", "id": "CVE-2021-45543" }, { "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R8000 before 1.0.4.74, RAX200 before 1.0.4.120, R8000P before 1.4.2.84, R7900P before 1.4.2.84, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R8000 prior to 1.0.4.74, RAX200 prior to 1.0.4.120, R8000P prior to 1.4.2.84, R7900P prior to 1.4.2.84, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45543" }, { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "VULMON", "id": "CVE-2021-45543" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45543", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017198", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2357", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45543", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45543" }, { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "NVD", "id": "CVE-2021-45543" }, { "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "id": "VAR-202112-2405", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.3106649133333334 }, "last_update_date": "2023-12-18T11:56:47.536000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0541", "trust": 0.8, "url": "https://kb.netgear.com/000064517/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0541" }, { "title": "Netgear NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176370" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "NVD", "id": "CVE-2021-45543" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064517/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0541" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45543" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45543" }, { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "NVD", "id": "CVE-2021-45543" }, { "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45543" }, { "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "db": "NVD", "id": "CVE-2021-45543" }, { "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45543" }, { "date": "2023-01-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "date": "2021-12-26T01:15:15.037000", "db": "NVD", "id": "CVE-2021-45543" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45543" }, { "date": "2023-01-10T00:56:00", "db": "JVNDB", "id": "JVNDB-2021-017198" }, { "date": "2022-01-06T14:03:57.403000", "db": "NVD", "id": "CVE-2021-45543" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2357" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2357" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017198" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2357" } ], "trust": 0.6 } }
var-202112-2366
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2366", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "NVD", "id": "CVE-2021-45582" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45582" } ] }, "cve": "CVE-2021-45582", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45582", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45582", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45582", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45582", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2376", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45582", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45582" }, { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "NVD", "id": "CVE-2021-45582" }, { "db": "NVD", "id": "CVE-2021-45582" }, { "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45582" }, { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "VULMON", "id": "CVE-2021-45582" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45582", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016913", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2376", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45582", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45582" }, { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "NVD", "id": "CVE-2021-45582" }, { "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "id": "VAR-202112-2366", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:34:42.528000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0090", "trust": 0.8, "url": "https://kb.netgear.com/000064104/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0090" }, { "title": "Netgear RBR750 and NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177085" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "NVD", "id": "CVE-2021-45582" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064104/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0090" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45582" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45582" }, { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "NVD", "id": "CVE-2021-45582" }, { "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45582" }, { "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "db": "NVD", "id": "CVE-2021-45582" }, { "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45582" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "date": "2021-12-26T01:15:16.890000", "db": "NVD", "id": "CVE-2021-45582" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45582" }, { "date": "2022-12-27T02:11:00", "db": "JVNDB", "id": "JVNDB-2021-016913" }, { "date": "2022-01-04T20:33:07.980000", "db": "NVD", "id": "CVE-2021-45582" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2376" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2376" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016913" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2376" } ], "trust": 0.6 } }
var-202112-2213
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, and RBR850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, and RBR850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2213", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "NVD", "id": "CVE-2021-45508" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45508" } ] }, "cve": "CVE-2021-45508", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45508", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45508", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45508", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45508", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2491", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2021-45508", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45508" }, { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "NVD", "id": "CVE-2021-45508" }, { "db": "NVD", "id": "CVE-2021-45508" }, { "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, and RBR850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, and RBR850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45508" }, { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "VULMON", "id": "CVE-2021-45508" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45508", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017146", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2491", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45508", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45508" }, { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "NVD", "id": "CVE-2021-45508" }, { "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "id": "VAR-202112-2213", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:55:16.812000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0490", "trust": 0.8, "url": "https://kb.netgear.com/000064133/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0490" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=175933" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "NVD", "id": "CVE-2021-45508" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064133/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0490" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45508" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45508" }, { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "NVD", "id": "CVE-2021-45508" }, { "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45508" }, { "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "db": "NVD", "id": "CVE-2021-45508" }, { "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45508" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "date": "2021-12-26T01:15:13.280000", "db": "NVD", "id": "CVE-2021-45508" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45508" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017146" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45508" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2491" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2491" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017146" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2491" } ], "trust": 0.6 } }
var-202006-0936
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0936", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14439" } ] }, "cve": "CVE-2020-14439", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006686", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44784", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006686", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14439", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14439", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006686", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44784", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1256", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request", "sources": [ { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "CNVD", "id": "CNVD-2021-44784" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14439", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006686", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44784", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1256", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" } ] }, "id": "VAR-202006-0936", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" } ] }, "last_update_date": "2023-12-18T12:17:01.750000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0064", "trust": 0.8, "url": "https://kb.netgear.com/000061942/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0064" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44784)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275031" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14439" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061942/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0064" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14439" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44784" }, { "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "db": "NVD", "id": "CVE-2020-14439" }, { "db": "CNNVD", "id": "CNNVD-202006-1256" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44784" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "date": "2020-06-18T17:15:13.047000", "db": "NVD", "id": "CVE-2020-14439" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1256" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44784" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006686" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14439" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1256" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1256" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006686" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1256" } ], "trust": 0.6 } }
var-202112-2332
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, EAX20 prior to 1.0.0.48, EAX80 prior to 1.0.1.64, EX7500 prior to 1.0.0.72, R6400 prior to 1.0.1.68, R6900P prior to 1.3.2.132, R7000 prior to 1.0.11.116, R7000P prior to 1.3.2.132, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, RAX200 prior to 1.0.3.106, RS400 prior to 1.5.1.80, XR300 prior to 1.0.3.68, MK62 prior to 1.0.6.110, MR60 prior to 1.0.6.110, R6400v2 prior to 1.0.4.106, R8000P prior to 1.4.1.66, RAX20 prior to 1.0.2.64, RAX45 prior to 1.0.2.82, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, R6700v3 prior to 1.0.4.106, R7900P prior to 1.4.1.66, RAX15 prior to 1.0.2.64, RAX50 prior to 1.0.2.82, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.22, RBR850 prior to 3.2.16.22, RBS750 prior to 3.2.16.22, RBS850 prior to 3.2.16.22, RBK752 prior to 3.2.16.22, and RBK852 prior to 3.2.16.22
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2332", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "r6400v2", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.106" }, { "model": "r6900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.132" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.22" }, { "model": "r8000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.66" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rs400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.5.1.80" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "r7900", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.38" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.22" }, { "model": "r7000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.3.2.132" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.22" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.22" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "r6400", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.68" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.22" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.64" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.24" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "mk62", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "r6700v3", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.4.106" }, { "model": "xr300", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.68" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rax50", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "r7000", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.11.116" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.22" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7900", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6900p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r6400", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7000p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "NVD", "id": "CVE-2021-45617" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45617" } ] }, "cve": "CVE-2021-45617", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 10.0, "confidentialityImpact": "Complete", "exploitabilityScore": null, "id": "CVE-2021-45617", "impactScore": null, "integrityImpact": "Complete", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-017552", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45617", "trust": 1.8, "value": "CRITICAL" }, { "author": "cve@mitre.org", "id": "CVE-2021-45617", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2411", "trust": 0.6, "value": "CRITICAL" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "NVD", "id": "CVE-2021-45617" }, { "db": "NVD", "id": "CVE-2021-45617" }, { "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, EAX20 prior to 1.0.0.48, EAX80 prior to 1.0.1.64, EX7500 prior to 1.0.0.72, R6400 prior to 1.0.1.68, R6900P prior to 1.3.2.132, R7000 prior to 1.0.11.116, R7000P prior to 1.3.2.132, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, RAX200 prior to 1.0.3.106, RS400 prior to 1.5.1.80, XR300 prior to 1.0.3.68, MK62 prior to 1.0.6.110, MR60 prior to 1.0.6.110, R6400v2 prior to 1.0.4.106, R8000P prior to 1.4.1.66, RAX20 prior to 1.0.2.64, RAX45 prior to 1.0.2.82, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, R6700v3 prior to 1.0.4.106, R7900P prior to 1.4.1.66, RAX15 prior to 1.0.2.64, RAX50 prior to 1.0.2.82, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.22, RBR850 prior to 3.2.16.22, RBS750 prior to 3.2.16.22, RBS850 prior to 3.2.16.22, RBK752 prior to 3.2.16.22, and RBK852 prior to 3.2.16.22", "sources": [ { "db": "NVD", "id": "CVE-2021-45617" }, { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "VULMON", "id": "CVE-2021-45617" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45617", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017552", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2411", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45617", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45617" }, { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "NVD", "id": "CVE-2021-45617" }, { "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "id": "VAR-202112-2332", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.29766340529411767 }, "last_update_date": "2023-12-18T13:59:56.992000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0156", "trust": 0.8, "url": "https://kb.netgear.com/000064505/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0156" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176390" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "NVD", "id": "CVE-2021-45617" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064505/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0156" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45617" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45617" }, { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "NVD", "id": "CVE-2021-45617" }, { "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45617" }, { "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "db": "NVD", "id": "CVE-2021-45617" }, { "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45617" }, { "date": "2023-01-25T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "date": "2021-12-26T01:15:18.567000", "db": "NVD", "id": "CVE-2021-45617" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-27T00:00:00", "db": "VULMON", "id": "CVE-2021-45617" }, { "date": "2023-01-25T05:10:00", "db": "JVNDB", "id": "JVNDB-2021-017552" }, { "date": "2022-01-10T16:18:25.997000", "db": "NVD", "id": "CVE-2021-45617" }, { "date": "2022-01-11T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2411" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2411" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017552" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2411" } ], "trust": 0.6 } }
var-202112-2206
Vulnerability from variot
Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Service operation interruption (DoS) It may be in a state. This affects EX7500 prior to 1.0.0.72, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, RBRE960 prior to 6.0.3.68, RBSE960 prior to 6.0.3.68, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2206", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbre960", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "6.0.3.68" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "rbse960", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "6.0.3.68" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbke963", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "6.0.3.68" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbke963", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbse960", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbre960", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "NVD", "id": "CVE-2021-45515" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbke963_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbke963:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbre960_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbre960:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbse960_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "6.0.3.68", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbse960:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45515" } ] }, "cve": "CVE-2021-45515", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "exploitabilityScore": 6.5, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 3.3, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45515", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "OTHER", "availabilityImpact": "High", "baseScore": 6.5, "baseSeverity": "Medium", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "JVNDB-2021-017112", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45515", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45515", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2329", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45515", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45515" }, { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "NVD", "id": "CVE-2021-45515" }, { "db": "NVD", "id": "CVE-2021-45515" }, { "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Service operation interruption (DoS) It may be in a state. This affects EX7500 prior to 1.0.0.72, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, RBRE960 prior to 6.0.3.68, RBSE960 prior to 6.0.3.68, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, and RBK852 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45515" }, { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "VULMON", "id": "CVE-2021-45515" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45515", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017112", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2329", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45515", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45515" }, { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "NVD", "id": "CVE-2021-45515" }, { "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "id": "VAR-202112-2206", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.15918323 }, "last_update_date": "2023-12-18T13:59:57.113000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Denial\u00a0of\u00a0Service\u00a0on\u00a0Some\u00a0Extenders\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0286", "trust": 0.8, "url": "https://kb.netgear.com/000064484/security-advisory-for-denial-of-service-on-some-extenders-and-wifi-systems-psv-2020-0286" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177074" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "NVD", "id": "CVE-2021-45515" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064484/security-advisory-for-denial-of-service-on-some-extenders-and-wifi-systems-psv-2020-0286" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45515" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45515" }, { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "NVD", "id": "CVE-2021-45515" }, { "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45515" }, { "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "db": "NVD", "id": "CVE-2021-45515" }, { "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45515" }, { "date": "2023-01-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "date": "2021-12-26T01:15:13.627000", "db": "NVD", "id": "CVE-2021-45515" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45515" }, { "date": "2023-01-04T06:53:00", "db": "JVNDB", "id": "JVNDB-2021-017112" }, { "date": "2022-01-05T16:54:10.490000", "db": "NVD", "id": "CVE-2021-45515" }, { "date": "2022-01-06T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2329" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2329" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017112" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2329" } ], "trust": 0.6 } }
var-202006-0929
Vulnerability from variot
Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A cross-site request forgery vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. The vulnerability stems from the fact that the WEB application does not fully verify whether the request comes from a trusted user. An attacker can use this vulnerability to send unexpected requests to the server through the affected client
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0929", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14432" } ] }, "cve": "CVE-2020-14432", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006797", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "CNVD-2021-44777", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006797", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14432", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14432", "trust": 1.0, "value": "HIGH" }, { "author": "NVD", "id": "JVNDB-2020-006797", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44777", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1247", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A cross-site request forgery vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. The vulnerability stems from the fact that the WEB application does not fully verify whether the request comes from a trusted user. An attacker can use this vulnerability to send unexpected requests to the server through the affected client", "sources": [ { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNVD", "id": "CNVD-2021-44777" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14432", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006797", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44777", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1247", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "id": "VAR-202006-0929", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" } ] }, "last_update_date": "2023-12-18T13:07:31.902000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Cross Site Request Forgery on Some WiFi Systems, PSV-2020-0049", "trust": 0.8, "url": "https://kb.netgear.com/000061937/security-advisory-for-cross-site-request-forgery-on-some-wifi-systems-psv-2020-0049" }, { "title": "Patch for Cross-site request forgery vulnerabilities in multiple NETGEAR products (CNVD-2021-44777)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275101" }, { "title": "Multiple NETGEAR Repair measures for product cross-site request forgery vulnerability", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=121995" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-352", "trust": 1.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14432" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061937/security-advisory-for-cross-site-request-forgery-on-some-wifi-systems-psv-2020-0049" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14432" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44777" }, { "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "db": "NVD", "id": "CVE-2020-14432" }, { "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44777" }, { "date": "2020-07-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "date": "2020-06-18T17:15:12.327000", "db": "NVD", "id": "CVE-2020-14432" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44777" }, { "date": "2020-07-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006797" }, { "date": "2020-06-22T17:28:47.637000", "db": "NVD", "id": "CVE-2020-14432" }, { "date": "2020-06-30T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1247" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1247" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR Cross-site request forgery vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006797" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "cross-site request forgery", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1247" } ], "trust": 0.6 } }
var-202112-2282
Vulnerability from variot
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.48, EAX80 prior to 1.0.1.64, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, R7960P prior to 1.4.1.66, RAX200 prior to 1.0.3.106, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, EX3700 prior to 1.0.0.90, MR60 prior to 1.0.6.110, R8000P prior to 1.4.1.66, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, EX3800 prior to 1.0.0.90, MS60 prior to 1.0.6.110, R7900P prior to 1.4.1.66, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2282", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "eax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.1.64" }, { "model": "ex6130", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.44" }, { "model": "ex3800", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "ms60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "r7900p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex6120", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.64" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "r7960p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax200", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "mr60", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.6.110" }, { "model": "cbr40", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.5.0.10" }, { "model": "rax80", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "ex3700", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.90" }, { "model": "rax50", "scope": "lte", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "eax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.48" }, { "model": "ex7500", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.0.72" }, { "model": "rax20", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "rbw30", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rax15", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.82" }, { "model": "r8000p", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.4.1.66" }, { "model": "rax75", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.3.106" }, { "model": "rbs40v", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "2.6.1.4" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rax45", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "1.0.2.72" }, { "model": "ex7500", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6120", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "r7960p", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax20", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "eax80", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "ex6130", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs40v", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbw30", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr40", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rax200", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "NVD", "id": "CVE-2021-45667" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.0.2.72", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45667" } ] }, "cve": "CVE-2021-45667", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "exploitabilityScore": 6.8, "impactScore": 2.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "LOW", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "None", "baseScore": 3.5, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-45667", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Low", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 1.7, "impactScore": 2.7, "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 0.7, "impactScore": 5.3, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 4.8, "baseSeverity": "Medium", "confidentialityImpact": "Low", "exploitabilityScore": null, "id": "CVE-2021-45667", "impactScore": null, "integrityImpact": "Low", "privilegesRequired": "High", "scope": "Changed", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45667", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45667", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202112-2463", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45667", "trust": 0.1, "value": "LOW" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45667" }, { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "NVD", "id": "CVE-2021-45667" }, { "db": "NVD", "id": "CVE-2021-45667" }, { "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX20 prior to 1.0.0.48, EAX80 prior to 1.0.1.64, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7500 prior to 1.0.0.72, R7960P prior to 1.4.1.66, RAX200 prior to 1.0.3.106, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, EX3700 prior to 1.0.0.90, MR60 prior to 1.0.6.110, R8000P prior to 1.4.1.66, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, EX3800 prior to 1.0.0.90, MS60 prior to 1.0.6.110, R7900P prior to 1.4.1.66, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45667" }, { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "VULMON", "id": "CVE-2021-45667" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45667", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017172", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2463", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45667", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45667" }, { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "NVD", "id": "CVE-2021-45667" }, { "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "id": "VAR-202112-2282", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.28974017916666667 }, "last_update_date": "2023-12-18T12:34:42.631000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Router,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0256", "trust": 0.8, "url": "https://kb.netgear.com/000064481/security-advisory-for-stored-cross-site-scripting-on-some-router-extenders-and-wifi-systems-psv-2020-0256" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=176225" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-79", "trust": 1.0 }, { "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "NVD", "id": "CVE-2021-45667" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064481/security-advisory-for-stored-cross-site-scripting-on-some-router-extenders-and-wifi-systems-psv-2020-0256" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45667" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/79.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45667" }, { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "NVD", "id": "CVE-2021-45667" }, { "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45667" }, { "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "db": "NVD", "id": "CVE-2021-45667" }, { "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45667" }, { "date": "2023-01-06T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "date": "2021-12-26T01:15:20.870000", "db": "NVD", "id": "CVE-2021-45667" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-06T00:00:00", "db": "VULMON", "id": "CVE-2021-45667" }, { "date": "2023-01-06T05:40:00", "db": "JVNDB", "id": "JVNDB-2021-017172" }, { "date": "2022-01-06T14:49:43.127000", "db": "NVD", "id": "CVE-2021-45667" }, { "date": "2022-01-07T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2463" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2463" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017172" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "XSS", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2463" } ], "trust": 0.6 } }
var-202112-2390
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2390", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.16.6" }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "NVD", "id": "CVE-2021-45558" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45558" } ] }, "cve": "CVE-2021-45558", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 5.1, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "Single", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.2, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45558", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "exploitabilityScore": 0.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.7, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 6.8, "baseSeverity": "Medium", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45558", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "High", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45558", "trust": 1.8, "value": "MEDIUM" }, { "author": "cve@mitre.org", "id": "CVE-2021-45558", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202112-2291", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-45558", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45558" }, { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "NVD", "id": "CVE-2021-45558" }, { "db": "NVD", "id": "CVE-2021-45558" }, { "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6", "sources": [ { "db": "NVD", "id": "CVE-2021-45558" }, { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "VULMON", "id": "CVE-2021-45558" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45558", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-016921", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2291", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45558", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45558" }, { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "NVD", "id": "CVE-2021-45558" }, { "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "id": "VAR-202112-2390", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T12:16:02.141000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0053", "trust": 0.8, "url": "https://kb.netgear.com/000064078/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0053" }, { "title": "Netgear NETGEAR Fixes for command injection vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=177053" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "Command injection (CWE-77) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "NVD", "id": "CVE-2021-45558" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064078/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0053" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45558" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/77.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45558" }, { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "NVD", "id": "CVE-2021-45558" }, { "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45558" }, { "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "db": "NVD", "id": "CVE-2021-45558" }, { "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45558" }, { "date": "2022-12-27T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "date": "2021-12-26T01:15:15.757000", "db": "NVD", "id": "CVE-2021-45558" }, { "date": "2021-12-25T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-04T00:00:00", "db": "VULMON", "id": "CVE-2021-45558" }, { "date": "2022-12-27T02:56:00", "db": "JVNDB", "id": "JVNDB-2021-016921" }, { "date": "2022-01-04T20:38:57.500000", "db": "NVD", "id": "CVE-2021-45558" }, { "date": "2022-01-05T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2291" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2291" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-016921" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "command injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2291" } ], "trust": 0.6 } }
var-202112-2218
Vulnerability from variot
Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2218", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbr850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk852", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "cbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "4.6.3.6" }, { "model": "rbs850", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbr750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbs750", "scope": "lt", "trust": 1.0, "vendor": "netgear", "version": "3.2.17.12" }, { "model": "rbk752", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbs750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "cbr750", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbk852", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null }, { "model": "rbr850", "scope": null, "trust": 0.8, "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "NVD", "id": "CVE-2021-45503" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-45503" } ] }, "cve": "CVE-2021-45503", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-45503", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-45503", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-45503", "trust": 1.8, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2021-45503", "trust": 1.0, "value": "CRITICAL" }, { "author": "CNNVD", "id": "CNNVD-202112-2490", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2021-45503", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45503" }, { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "NVD", "id": "CVE-2021-45503" }, { "db": "NVD", "id": "CVE-2021-45503" }, { "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12", "sources": [ { "db": "NVD", "id": "CVE-2021-45503" }, { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "VULMON", "id": "CVE-2021-45503" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-45503", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2021-017141", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202112-2490", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-45503", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45503" }, { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "NVD", "id": "CVE-2021-45503" }, { "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "id": "VAR-202112-2218", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.14124016 }, "last_update_date": "2023-12-18T13:17:34.589000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0474", "trust": 0.8, "url": "https://kb.netgear.com/000064127/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0474" }, { "title": "Netgear RBR750 and NETGEAR Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=175931" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "NVD", "id": "CVE-2021-45503" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://kb.netgear.com/000064127/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0474" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45503" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/287.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-45503" }, { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "NVD", "id": "CVE-2021-45503" }, { "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-45503" }, { "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "db": "NVD", "id": "CVE-2021-45503" }, { "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-12-26T00:00:00", "db": "VULMON", "id": "CVE-2021-45503" }, { "date": "2023-01-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "date": "2021-12-26T01:15:13.033000", "db": "NVD", "id": "CVE-2021-45503" }, { "date": "2021-12-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-01-05T00:00:00", "db": "VULMON", "id": "CVE-2021-45503" }, { "date": "2023-01-05T02:24:00", "db": "JVNDB", "id": "JVNDB-2021-017141" }, { "date": "2022-07-12T17:42:04.277000", "db": "NVD", "id": "CVE-2021-45503" }, { "date": "2022-07-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202112-2490" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2490" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-017141" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "authorization issue", "sources": [ { "db": "CNNVD", "id": "CNNVD-202112-2490" } ], "trust": 0.6 } }
var-202006-0901
Vulnerability from variot
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands with the help of specially crafted requests
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0901", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "rbk752", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs850", "scope": "lt", "trust": 1.6, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk752", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk753s", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk842", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk852", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbk853", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbr840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs750", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" }, { "model": "rbs840", "scope": "eq", "trust": 0.8, "vendor": "netgear", "version": "3.2.15.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2020-14442" } ] }, "cve": "CVE-2020-14442", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Adjacent Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "JVNDB-2020-006683", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 6.5, "id": "CNVD-2021-44787", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "cve@mitre.org", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 6.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 8.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2020-006683", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2020-14442", "trust": 1.0, "value": "HIGH" }, { "author": "cve@mitre.org", "id": "CVE-2020-14442", "trust": 1.0, "value": "CRITICAL" }, { "author": "NVD", "id": "JVNDB-2020-006683", "trust": 0.8, "value": "High" }, { "author": "CNVD", "id": "CNVD-2021-44787", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-202006-1266", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands with the help of specially crafted requests", "sources": [ { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "CNVD", "id": "CNVD-2021-44787" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2020-14442", "trust": 3.0 }, { "db": "JVNDB", "id": "JVNDB-2020-006683", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2021-44787", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202006-1266", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" } ] }, "id": "VAR-202006-0901", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" } ], "trust": 1.0097272085714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" } ] }, "last_update_date": "2023-12-18T14:00:29.366000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0103", "trust": 0.8, "url": "https://kb.netgear.com/000061947/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0103" }, { "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44787)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/275066" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-77", "trust": 1.0 }, { "problemtype": "CWE-78", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14442" }, { "trust": 1.6, "url": "https://kb.netgear.com/000061947/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0103" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14442" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2021-44787" }, { "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "db": "NVD", "id": "CVE-2020-14442" }, { "db": "CNNVD", "id": "CNNVD-202006-1266" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44787" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "date": "2020-06-18T17:15:13.327000", "db": "NVD", "id": "CVE-2020-14442" }, { "date": "2020-06-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1266" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-24T00:00:00", "db": "CNVD", "id": "CNVD-2021-44787" }, { "date": "2020-07-15T00:00:00", "db": "JVNDB", "id": "JVNDB-2020-006683" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2020-14442" }, { "date": "2020-07-02T00:00:00", "db": "CNNVD", "id": "CNNVD-202006-1266" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1266" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural NETGEAR On the device OS Command injection vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2020-006683" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "operating system commend injection", "sources": [ { "db": "CNNVD", "id": "CNNVD-202006-1266" } ], "trust": 0.6 } }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado.\u0026#xa0;Esto afecta a RBS40V versiones anteriores a 2.6.1.4, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25." } ], "id": "CVE-2020-35794", "lastModified": "2024-11-21T05:28:07.223", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.017", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062629/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0034" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45635", "lastModified": "2024-11-21T06:32:44.260", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.413", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14427", "lastModified": "2024-11-21T05:03:14.637", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:11.920", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061935/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0042" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45598", "lastModified": "2024-11-21T06:32:37.700", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.623", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064144/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0544" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064144/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0544" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C1280B1-A2DF-4CAB-AB19-6B463206AA3D", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", "matchCriteriaId": "A80B06A1-81B5-4C33-89F6-EC3F6E3068B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76C658A4-BF82-40CE-A5E1-C9F3DA1A9B0B", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B25A18F-DD96-45FE-B098-71E60CB0FFFE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A3A6655-B468-46FB-84D7-2294D4243C91", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BFCD9A8-1846-48C4-9F14-3866E983FB74", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C3B3284-B11F-4752-9C6A-0B5BECA3DB2B", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "E526746E-1ED6-492E-B28C-A1CA8235D9FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACEAC1F2-EEAE-4880-B6C0-FFAAA29685F1", "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B59B0C17-2714-48E8-8911-E72488CE32E3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7658849-0743-487B-803F-D49680EDF185", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F898DC9-9250-47DF-844C-F7308365135B", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79B24229-6AC2-489D-B542-4DAA7E630180", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5B842D-2275-4968-997B-A70A67CBDBEC", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "matchCriteriaId": "C91CADFA-59DB-4B6C-A914-848884F4A4BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23D4F7E6-C042-434E-87B8-55DB18B08B0A", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "matchCriteriaId": "3C395D49-57F9-4BC1-8619-57127355B86B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6524B85E-23AC-4983-8331-96E12899B773", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6330:-:*:*:*:*:*:*:*", "matchCriteriaId": "D621D26D-B144-424A-A9CB-19488399ACC1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F105F6F-ECD3-411D-924E-94BCF036C1EA", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B302909-29CF-4E53-9CCB-8664D3FCB03A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "478CE991-5E30-438D-94B0-0E15A29E27BD", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E32C097-6EDF-4C81-A375-028DB67B6231", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "19D625E4-17F4-44EF-9A51-DA0BAD4835F2", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C5AB644-B80D-48A3-B794-C483FEFAFDED", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9793286-86D2-43BF-B9B8-823C05BCAE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCCFD041-9413-4E37-8C4D-F50D1B10582B", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8956A99-1071-42A7-8984-D7134E755CBF", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3408536D-FC77-48C5-AD15-C5A170D7417C", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", "matchCriteriaId": "598B48C5-4706-4431-8C5A-DA496DD1052F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1D59AC0-2859-46C0-B050-3BB8E3E9CB06", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02672757-31FD-4338-AF2C-63FD1D7C1A19", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9FC6398-60A5-4003-A294-C96AE6DBCED5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D208F2CA-DB20-4C82-8FFF-B99EBFE29713", "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02279B20-D951-46CE-B339-452BC585A4F3", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", "matchCriteriaId": "FECB83F9-D417-4FD3-B293-87BC177E3AEB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B452611A-43C5-401B-95BD-189020B5C65C", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFD1A65C-F10F-4C52-8B6D-69992E512EB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "237C68C0-C2A9-4F71-9E08-547F2A317CBC", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F68AC3B-A31F-4AB0-89E9-BFFDE427AD3B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63697E3A-AAA3-42E7-8116-93C6548D3AB7", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DA5420D-DD64-4A9C-9B5F-784F0ED2B464", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C393DBF4-8281-4611-B591-CDB9DF0AA958", "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4171EB00-3664-43D5-9B62-A3538C358142", "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9800CB2-C14A-406B-B1FF-B1B62862EBDB", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44537647-E0B2-477D-98A5-7EA850BF3321", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA8D0327-0A72-44EC-9CC2-6CAF6A0C08B2", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F030129E-95C6-4C31-92A6-DABCDC1B534B", "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B377E02-0228-4A2F-90F3-A82E7E964B37", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57314D03-64B1-4973-9D36-5D22A71DBCBB", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DCE56F2-5A45-4B31-99EF-1D8455C71E5C", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B697A877-214C-4701-AA9B-FE9C23FDBCEB", "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49D5D1E8-637A-4970-8753-6A3FCA8FAC64", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A3B894E-E712-477A-9960-30AFAB2C35CF", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71AE85C-74C4-42C1-BF54-89B6EC38C707", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EC30751-F447-45A7-8C57-B73042869EA5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk12:-:*:*:*:*:*:*:*", "matchCriteriaId": "D5465A78-4826-4F72-9CBE-528CBF286A79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8246B8D3-8455-43B1-B0FA-F677B8FF84F5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr10:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DADAA79-9A5C-4B6F-A58D-704ACD1C3334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28DA498C-B466-422E-BAD2-A1F9A15B157F", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs10:-:*:*:*:*:*:*:*", "matchCriteriaId": "32BAB5C0-F645-4A90-833F-6345335FA1AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E72FDDB4-0802-467B-A255-06C8CE1A0B92", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C80BEFF8-7094-4F21-B9E7-EE5C8B9DF3B3", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04F03BE5-1440-4BC4-B902-97E702ED0ADF", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09631703-25CD-40CB-80A8-AADD43939507", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E21623E-9977-486F-93B1-858FC407E9D1", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A32769CF-7D0A-4A3F-AF20-6202CA0C6870", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E3BFCB-BFF8-4722-BE48-5FA93CACD3AD", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "39D6318D-F5A2-4469-B508-075F2825F0FA", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F44708A-C946-4E0F-9D6C-A91AFB4C9EF3", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5C6DF5F-FEFB-4A30-87CC-379E726AE181", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "451C5603-927A-4EB9-BF9D-150FE16A48F8", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B22B149-BD16-42A0-BB1D-DEF483F6B5E1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "921A8CFC-D86E-4674-998E-31F4F956B5DC", "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "051E8D2A-0EB0-43A7-9AAA-8519B8CC7FE0", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BCFB551-95C6-4EEF-83F0-4246F67E6668", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89AB672D-DD24-483E-B69D-7E46AF199483", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "matchCriteriaId": "E12892C8-5E01-49A6-BF47-09D630377093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a AC2100 versiones anteriores a 1.2.0.72, AC2400 versiones anteriores a 1.2.0.72, AC2600 versiones anteriores a 1.2.0.72, CBK40 versiones anteriores a 2.5.0.10, CBR40 versiones anteriores a 2.5.0.10, D7800 versiones anteriores a 1.0.1.58, EAX20 versiones anteriores a 1.0.0.36, EAX80 versiones anteriores a 1.0.1.62, EX7500 versiones anteriores a 1.0.0.68, MK62 versiones anteriores a 1.0.5.102, MR60 versiones anteriores a 1.0.5.102, MS60 versiones anteriores a 1.0.5.102, R6120 versiones anteriores a 1.0.0.70, R6220 versiones anteriores a 1.1.0.100, R6230 versiones anteriores a 1.1.0.100, R6260 versiones anteriores a 1.1.0.76, R6330 versiones anteriores a 1.1.0.76, R6350 versiones anteriores a 1.1.0.76, R6400 versiones anteriores a 1.0.1.62, R6400v2 versiones anteriores a 1.0.4.98, R6700 versiones anteriores a 1.0.2.16, R6700v2 versiones anteriores a 1.2.0.72, R6700v3 versiones anteriores a 1.0.4.98, R6800 versiones anteriores a 1.2.0.72, R6850 versiones anteriores a 1.1. 0.76, R6900P versiones anteriores a 1.3.2.124, R6900 versiones anteriores a 1.0.2.16, R6900v2 versiones anteriores a 1.2.0.72, R7000 versiones anteriores a 1.0.11.106, R7000P versiones anteriores a 1.3.2.124, R7200 versiones anteriores a 1.2.0.72, R7350 versiones anteriores a 1.2.0.72, R7400 versiones anteriores a 1.2.0.72, R7450 versiones anteriores a 1.2.0.72, R7800 versiones anteriores a 1.0.2.74, R7850 versiones anteriores a 1.0.5.60, R7900 versiones anteriores a 1.0.4.26, R7900P versiones anteriores a 1.4.1.62, R7960P versiones anteriores a 1.4.1.62, R8000 versiones anteriores a 1.0.4.58, R8000P versiones anteriores a 1.4.1.62, R8900 versiones anteriores a 1.0.5.24, R9000 versiones anteriores a 1.0.5.24, RAX120 versiones anteriores a 1.0.1.136, RAX15 versiones anteriores a 1.0.1.64, RAX20 versiones anteriores a 1.0.1.64, RAX200 versiones anteriores a 1.0. 2.102, RAX45 versiones anteriores a 1.0.2.64, RAX50 versiones anteriores a 1.0.2.64, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102, RBK12 versiones anteriores a 2.6.1.44, RBR10 versiones anteriores a 2.6.1.44, RBS10 versiones anteriores a 2.6.1.44, RBK20 versiones anteriores a 2.6.1.38, RBR20 versiones anteriores a 2.6.1.36, RBS20 versiones anteriores a 2.6.1.38, RBK40 versiones anteriores a 2.6.1.38, RBR40 versiones anteriores a 2.6.1.36, RBS40 versiones anteriores a 2.6.1.38, RBK50 versiones anteriores a 2.6.1.40, RBR50 versiones anteriores a 2.6.1.40, RBS50 versiones anteriores a 2.6.1.40, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK842 versiones anteriores a 3.2.16.6, RBR840 versiones anteriores a 3.2.16.6, RBS840 versiones anteriores a 3.2. 16.6, RBK852 versiones anteriores a 3. 2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RS400 versiones anteriores a 1.5.0.48, XR300 versiones anteriores a 1.0.3.50, XR450 versiones anteriores a 2.3.2.66, XR500 versiones anteriores a 2.3.2.66 y XR700 versiones anteriores a 1.0.1.34." } ], "id": "CVE-2020-35795", "lastModified": "2024-11-21T05:28:07.420", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.080", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45506", "lastModified": "2024-11-21T06:32:22.267", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.183", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45569", "lastModified": "2024-11-21T06:32:32.893", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064091/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0077" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064091/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0077" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12.\n" } ], "id": "CVE-2021-45600", "lastModified": "2024-11-21T06:32:38.010", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.713", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064146/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0555" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17. 12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29081", "lastModified": "2024-11-21T06:00:40.503", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.310", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063012/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0465" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6." } ], "id": "CVE-2021-45584", "lastModified": "2024-11-21T06:32:35.447", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.977", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0092" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064106/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0092" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rbk752 | - | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado . Esto afecta a RAX200 versiones anteriores a 1.0.3.106, RAX75 versiones anteriores a 1.0.3.106, RAX80 versiones anteriores a 1.0.3.106, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45537", "lastModified": "2024-11-21T06:32:27.310", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.747", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | ex6120_firmware | * | |
netgear | ex6120 | - | |
netgear | ex6130_firmware | * | |
netgear | ex6130 | - | |
netgear | ex7000_firmware | * | |
netgear | ex7000 | - | |
netgear | ex7500_firmware | * | |
netgear | ex7500 | - | |
netgear | ex3700_firmware | * | |
netgear | ex3700 | - | |
netgear | ex3800_firmware | * | |
netgear | ex3800 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8ECBE89E-3C81-470A-80C0-F742D7ABC66D", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D32948E-0E3F-4F1E-9BF8-AA159659B248", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C2D1A25A-22F9-49BF-8335-61EC6D0D1951", "versionEndExcluding": "1.0.1.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CAFA0844-677F-4753-9289-DFEB4B59D689", "versionEndExcluding": "1.0.1.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A65EE9FC-A015-4D92-8DA3-40C8594D843D", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED72FFCA-F5A8-480D-8A29-C14FFC490B33", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "532EF10D-71E1-476B-A9EA-4454F2BB9B34", "versionEndExcluding": "4.6.3.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C2F2D01-7924-42D2-A07E-15AB1D37810F", "versionEndExcluding": "4.6.3.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0772693C-678C-4AB3-9E7B-D2B4DB7770D9", "versionEndExcluding": "4.6.3.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects EX6120 before 1.0.0.66, EX6130 before 1.0.0.46, EX7000 before 1.0.1.106, EX7500 before 1.0.1.76, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, RBR850 before 4.6.3.9, RBS850 before 4.6.3.9, and RBK852 before 4.6.3.9." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a los dispositivos EX6120 versiones anteriores a 1.0.0.66, EX6130 versiones anteriores a 1.0.0.46, EX7000 versiones anteriores a 1.0.1.106, EX7500 versiones anteriores a 1.0.1.76, EX3700 versiones anteriores a 1.0.0.94, EX3800 versiones anteriores a 1.0.0.94, RBR850 versiones anteriores a 4.6.3.9, RBS850 versiones anteriores a 4.6.3.9 y RBK852 versiones anteriores a 4.6.3.9" } ], "id": "CVE-2021-45533", "lastModified": "2024-11-21T06:32:26.620", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.553", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064458/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0062" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14431", "lastModified": "2024-11-21T05:03:15.320", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.250", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061944/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0068" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14442", "lastModified": "2024-11-21T05:03:17.260", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.327", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061947/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0103" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45586", "lastModified": "2024-11-21T06:32:35.763", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.070", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064108/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0094" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064108/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0094" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | r6400_firmware | * | |
netgear | r6400 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA1BB56F-20B5-4A79-AE9D-429A011EAA4C", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E06EFF-9D71-43DB-A304-9A41998FD68A", "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects R6400 before 1.0.1.70, R7000 before 1.0.11.126, R6900P before 1.3.3.140, R7000P before 1.3.3.140, R8000 before 1.0.4.74, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a R6400 versiones anteriores a 1.0.1.70, a R7000 versiones anteriores a 1.0.11.126, a R6900P versiones anteriores a 1.3.3.140, a R7000P versiones anteriores a 1.3.3.140, a R8000 versiones anteriores a 1.0.4.74, a RBK852 versiones anteriores a 3.2.10.11, a RBR850 versiones anteriores a 3.2.10.11 y a RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2021-45516", "lastModified": "2024-11-21T06:32:23.850", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 2.7, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:N/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 4.7, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.670", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064060/Security-Advisory-for-Denial-of-Service-on-Some-Routers-and-WiFi-Systems-PSV-2019-0115" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064060/Security-Advisory-for-Denial-of-Service-on-Some-Routers-and-WiFi-Systems-PSV-2019-0115" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F2A04BB9-E816-49B5-B539-4B36A5CFFA22", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F4BC21D-8354-4C71-BE68-9D1A14A9471F", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3DCFE88-1262-43BF-88BB-B26658EDEDF1", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F3F88DD-CE38-45A8-990A-4770A480D1BF", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D989E9B-5626-4238-877A-FFB0FC1C6352", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200v4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE1AC249-D64C-4E61-A22A-1498712D2758", "versionEndExcluding": "1.0.0.114", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200v4:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BE59214-C8A1-4337-A54C-E4E8C149B241", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "953A4436-6F98-494C-B184-354E577F8E59", "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF7B1DD1-E197-461C-9537-C6D1DF2F6D7D", "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3920_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33BDAF99-3E64-427E-ACAF-AEFB75401C72", "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3920:-:*:*:*:*:*:*:*", "matchCriteriaId": "E576341B-2426-4F4D-8DF4-0A6D462656A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDB99B74-2E41-4986-96BB-B728ED32405B", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "02E7CA7E-E6CA-4BAB-8F40-4731EA523D91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8491DCE-15CC-42F2-B253-68FEDF731DF5", "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB84CD03-765C-4D4F-A176-364F8E72A4E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1AA1E29-118C-4299-91FA-2C8584EC6F6C", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B845CEBF-A8A2-474B-9094-43AA53560150", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "22C12B59-DF06-4133-9F30-24EB02CECB9C", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*", "matchCriteriaId": "46452E97-9347-4788-9570-1EECECC7255E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9CB304C9-D59C-4FAB-A034-1B2B7B41AA71", "versionEndExcluding": "1.0.3.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*", "matchCriteriaId": "3186CC67-B567-4A0C-BD2C-0433716FBD1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6920_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FF964D1-1FCE-467B-8B7F-8189CDF728D4", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6920:-:*:*:*:*:*:*:*", "matchCriteriaId": "65914D7F-39EA-489B-8DE7-8547AFC05F64", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A096742-1FFA-4C19-B697-EC5154411CF2", "versionEndExcluding": "1.0.1.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B59B0C17-2714-48E8-8911-E72488CE32E3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7658849-0743-487B-803F-D49680EDF185", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2CE369F2-053B-4F67-B295-54EE41C6C4DA", "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD8455EE-AFAD-445D-910B-E8D9F02E8B1B", "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "478CE991-5E30-438D-94B0-0E15A29E27BD", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E32C097-6EDF-4C81-A375-028DB67B6231", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCCFD041-9413-4E37-8C4D-F50D1B10582B", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "19D625E4-17F4-44EF-9A51-DA0BAD4835F2", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:-:*:*:*:*:*:*:*", "matchCriteriaId": "21B27F11-4262-4CE1-8107-B365A7C152F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1D59AC0-2859-46C0-B050-3BB8E3E9CB06", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D208F2CA-DB20-4C82-8FFF-B99EBFE29713", "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8841DA90-D1B1-40EB-809D-14C014337AAB", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4171EB00-3664-43D5-9B62-A3538C358142", "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9800CB2-C14A-406B-B1FF-B1B62862EBDB", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44537647-E0B2-477D-98A5-7EA850BF3321", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA8D0327-0A72-44EC-9CC2-6CAF6A0C08B2", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F030129E-95C6-4C31-92A6-DABCDC1B534B", "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B377E02-0228-4A2F-90F3-A82E7E964B37", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6324787-AE71-423A-B853-8B22CA3A5294", "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72C4B203-565A-43BC-9800-274060CE23F2", "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49D5D1E8-637A-4970-8753-6A3FCA8FAC64", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rx45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "867CC271-D1F9-4289-9859-7FE084C2BB5C", "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rx45:-:*:*:*:*:*:*:*", "matchCriteriaId": "20AD88BE-1321-4029-8C31-E558DCBDE9E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "41D61A7C-BF7E-4A84-A08B-C9FF449AF952", "versionEndExcluding": "1.0.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5C6DF5F-FEFB-4A30-87CC-379E726AE181", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "451C5603-927A-4EB9-BF9D-150FE16A48F8", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B22B149-BD16-42A0-BB1D-DEF483F6B5E1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCFCED24-A687-4C5E-BE2E-60C2189254CF", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "935C7519-678D-4C40-BD35-3F281890C7C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "993FD563-493C-460C-B379-E02A90295434", "versionEndExcluding": "2.5.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "921A8CFC-D86E-4674-998E-31F4F956B5DC", "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9FCAF1C-DB77-402B-98D2-8C3FE7DBA8FF", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "65FACC9E-3E0E-4416-9280-706F4FCE436A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3500rp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D0EEFD6D-A6DC-4F91-9A6A-4F96712ED151", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3500rp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A98880D5-40DF-41A2-9924-9CACF78701EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6803A2E5-5BCE-4DE6-A0EB-3463C81FAD0C", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "37F227D8-332F-4D24-BAEA-AA5DB3E3EC95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5464DA45-2B33-430F-A16E-B1FE072B1376", "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "252E5C7B-EF02-4374-A43E-02FAA9E697D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01374C4A-4D12-4E77-AF7C-459C32C3579B", "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "31247E55-E754-46D0-9A46-B0D319C21221", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500lv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F667392E-F63E-4186-9BA3-7F9A4AA3EC67", "versionEndExcluding": "1.2.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500lv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "FC3F6D58-D900-41B4-8626-58928866208A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects CBR40 before 2.5.0.10, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100 before 1.0.2.28, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150 before 1.0.0.46, EX6200 before 1.0.3.94, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6250 before 1.0.4.42, R6300v2 before 1.0.4.42, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v3 before 1.0.4.98, R6700 before 1.0.2.16, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.32, RAX50 before 1.0.2.32, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V-200 before 1.0.0.46, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3500RP before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, WNR3500Lv2 before 1.2.0.62, and XR300 before 1.0.3.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, D6220 versiones anteriores a 1.0.0.60, D6400 versiones anteriores a 1.0.0.94, D7000v2 versiones anteriores a 1.0.0.62, D8500 versiones anteriores a 1.0.3.50, DC112A versiones anteriores a 1.0.0.48, DGN2200v4 versiones anteriores a 1.0.0.114, EAX20 versiones anteriores a 1.0.0.36, EAX80 versiones anteriores a 1.0.1.62, EX3700 versiones anteriores a 1.0.0.84, EX3800 versiones anteriores a 1.0.0.84, EX3920 versiones anteriores a 1.0.0.84, EX6000 versiones anteriores a 1.0.0.44, EX6100 versiones anteriores a 1.0.2.28, EX6120 versiones anteriores a 1.0.0.54, EX6130 versiones anteriores a 1.0.0.36, EX6150 versiones anteriores a 1.0.0.46, EX6200 versiones anteriores a 1.0.3.94, EX6920 versiones anteriores a 1.0.0.54, EX7000 versiones anteriores a 1.0.1.90, EX7500 versiones anteriores a 1.0.0.68, MK62 versiones anteriores a 1.0.5.102, MR60 versiones anteriores a 1.0.5.102, MS60 versiones anteriores a 1.0.5.102, R6250 versiones anteriores a 1.0.4.42, R6300v2 versiones anteriores a 1.0.4.42, R6400 versiones anteriores a 1.0.1.62, R6400v2 versiones anteriores a 1.0.4.98, R6700v3 versiones anteriores a 1.0.4.98, R6700 versiones anteriores a 1.0.2.16, R6900P versiones anteriores a 1.3.2.124, R6900 versiones anteriores a 1.0.2.16, R7000 versiones anteriores a 1.0.11.106, R7000P versiones anteriores a 1.3.2.124, R7100LG versiones anteriores a 1.0.0.56, R7850 versiones anteriores a 1.0.5.60, R7900 versiones anteriores a 1.0.4.26, R7900P versiones anteriores a 1.4. 1.62, R7960P versiones anteriores a 1.4.1.62, R8000 versiones anteriores a 1.0.4.58, R8000P versiones anteriores a 1.4.1.62, R8300 versiones anteriores a 1.0.2.134, R8500 versiones anteriores a 1.0.2.134, RAX15 versiones anteriores a 1.0.1.64, RAX20 versiones anteriores a 1.0.1.64, RAX200 versiones anteriores a 1.0.2.102, RAX45 versiones anteriores a 1.0.2.32, RAX50 versiones anteriores a 1.0.2.32, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK842 versiones anteriores a 3.2.16.6, RBR840 versiones anteriores a 3.2.16.6, RBS840 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBS40V-200 versiones anteriores a 1.0.0.46, RBW30 versiones anteriores a 2.5.0.4, RS400 versiones anteriores a 1.5.0.48, WN2500RPv2 versiones anteriores a 1.0 .1.56, WN3500RP versiones anteriores a 1.0.0.28, WNDR3400v3 versiones anteriores a 1.0.1.32, WNR1000v3 versiones anteriores a 1.0.2.78, WNR2000v2 versiones anteriores a 1.2.0.12, WNR3500Lv2 versiones anteriores a 1.2.0.62 y XR300 versiones anteriores a 1.0.3.50." } ], "id": "CVE-2020-35796", "lastModified": "2024-11-21T05:28:07.700", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.160", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062717/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2020-0201" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062717/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-WiFi-Systems-PSV-2020-0201" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45631", "lastModified": "2024-11-21T06:32:43.630", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.233", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C2D1C234-22F1-4837-9D04-059170A97072", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29757651-068E-4646-AAD8-2CF8FD08B34C", "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr80:-:*:*:*:*:*:*:*", "matchCriteriaId": "2A086E76-3F23-4C21-AC96-F11372A8A186", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1582E16D-ACEE-4E33-9D52-9DD25C035EA8", "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms80:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE1A0669-790A-4EE7-A0DC-6E1023D6B4F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, D7000v2 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6. 116, MS60 versiones anteriores a 1.0.6.116, MR80 versiones anteriores a 1.1.2.20, MS80 versiones anteriores a 1.1.2.20, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX45 versiones anteriores a 1.0.3. 96, RAX50 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX35v2 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3. 2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, y XR1000 versiones anteriores a 1.0.0.58" } ], "id": "CVE-2021-45613", "lastModified": "2024-11-21T06:32:40.303", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.383", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45630", "lastModified": "2024-11-21T06:32:43.477", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.187", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17. 12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29074", "lastModified": "2024-11-21T06:00:39.400", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.797", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26899", "lastModified": "2024-11-21T05:20:26.647", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:13.870", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45509", "lastModified": "2024-11-21T06:32:22.730", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.333", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064148/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0564" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064148/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0564" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA48F47-FC18-4953-BA90-1F4F3695A2BE", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC9EE9DE-DD58-46A9-87FB-D284EBE0ACC1", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EB8CD19-4963-42A8-B9E6-63ED5EC35119", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0095B9D4-E161-4050-B283-2166CB86CB24", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0702F9B6-2DAC-4308-8737-9F85AD28E847", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E06EFF-9D71-43DB-A304-9A41998FD68A", "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4195BC65-A849-4C3A-B726-E013CEB57F32", "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3AE70236-D1C6-4B58-8385-1FA5F71916AF", "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, EAX20 versiones anteriores a 1.0.0.58, EAX80 versiones anteriores a 1.0.1.68, EX7500 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0.6.116, R6400v2 versiones anteriores a 1.0. 4.118, R6700v3 versiones anteriores a 1.0.4.118, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11.126, R7000P versiones anteriores a 1.3.3.140, R7850 versiones anteriores a 1.0.5.74, R7900 versiones anteriores a 1.0.4.46, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000 versiones anteriores a 1.0.4.74, R8000P versiones anteriores a 1. 4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1. 0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80, XR1000 versiones anteriores a 1.0.0.58 y XR300 versiones anteriores a 1.0.3.68" } ], "id": "CVE-2021-45612", "lastModified": "2024-11-21T06:32:40.110", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.337", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbr852_firmware | * | |
netgear | rbr852 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "914BA8A0-4D5A-4DFE-BD47-E5CC32EAC2FB", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr852:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2538467-3383-4666-B8C7-D2DB1448D102", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBR852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45504", "lastModified": "2024-11-21T06:32:21.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.083", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064128/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0475" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064128/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0475" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45560", "lastModified": "2024-11-21T06:32:31.343", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.847", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064081/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0057" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064081/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0057" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3DD37BF-8664-412F-9A71-58880AF20242", "versionEndIncluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, R7960P versiones anteriores a 1. 4.1.66, RAX200 versiones anteriores a 1.0.3.106, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.6.110, R8000P versiones anteriores a 1.4.1.66, RAX20 versiones anteriores a 1.0.2. 82, RAX45 versiones anteriores a 1.0.2.72, RAX80 versiones anteriores a 1.0.3.106, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.6.110, R7900P versiones anteriores a 1.4.1.66, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1.0.2. 72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45667", "lastModified": "2024-11-21T06:32:49.870", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.7, "impactScore": 5.3, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:20.870", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45597", "lastModified": "2024-11-21T06:32:37.540", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.580", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064142/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0539" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064142/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0539" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25 y RBS840 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14436", "lastModified": "2024-11-21T05:03:16.207", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.750", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061933/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0039" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial.\u0026#xa0;Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-26901", "lastModified": "2024-11-21T05:20:26.950", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:14.730", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062353/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0036" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062353/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0036" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-26900", "lastModified": "2024-11-21T05:20:26.793", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:14.370", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062354/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0032" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062354/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0032" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14441", "lastModified": "2024-11-21T05:03:17.100", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.233", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061946/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0071" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45565", "lastModified": "2024-11-21T06:32:32.250", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.083", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064086/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0069" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064086/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0069" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2020-26907", "lastModified": "2024-11-21T05:20:27.897", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:16.653", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062347/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0264" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45582", "lastModified": "2024-11-21T06:32:35.073", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.890", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064104/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0090" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064104/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0090" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDC785-6FEC-4D94-86D1-8E55FB0CA6C1", "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E06EFF-9D71-43DB-A304-9A41998FD68A", "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50", "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4195BC65-A849-4C3A-B726-E013CEB57F32", "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 3.2.18.2, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 3.2.18.2, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0.6.116, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11.126, R7000P versiones anteriores a 1. 3.3.140, R7850 versiones anteriores a 1.0.5.68, R7900 versiones anteriores a 1.0.4.46, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000 versiones anteriores a 1.0.4.68, R8000P versiones anteriores a 1.4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3. 96, RAX200 versiones anteriores a 1.0.4.120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4. 120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80 y XR1000 versiones anteriores a 1.0.0.58" } ], "id": "CVE-2021-45616", "lastModified": "2024-11-21T06:32:40.943", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.520", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064527/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0576" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064527/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0576" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45559", "lastModified": "2024-11-21T06:32:31.163", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.803", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064079/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0055" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064079/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0055" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45581", "lastModified": "2024-11-21T06:32:34.910", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.843", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064103/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0089" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064103/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0089" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autentificado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29070", "lastModified": "2024-11-21T06:00:38.747", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.483", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063019/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Routers-PSV-2020-0530" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45634", "lastModified": "2024-11-21T06:32:44.103", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.367", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | r7850_firmware | * | |
netgear | r7850 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R7850 versiones anteriores a 1.0.5.74, a R7900P versiones anteriores a 1.4.2.84, a R7960P versiones anteriores a 1.4.2.84, a R8000 versiones anteriores a 1.0.4.74, a R8000P versiones anteriores a 1.4.2.84, a RAX200 versiones anteriores a 1. 0.4.120, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45544", "lastModified": "2024-11-21T06:32:28.503", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.087", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064518/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0556" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064518/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0556" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADF65DC4-51D5-4C38-B28D-7EA93B1734A3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "888A8E0F-93DD-436D-B00C-F469C3BD6E5B", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08668CFE-EE8B-4EE9-8B9D-FFCB45EE27D2", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "160F53B0-8430-4D85-8ABC-0A64B27DDFBD", "versionEndExcluding": "1.0.3.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A59578F-1A3F-428B-A995-572C8E93C15C", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E273CF7-2DB6-4641-8753-810949D631B0", "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "049629DD-9E4F-4F47-98B0-C9FD457B74A0", "versionEndExcluding": "1.0.4.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "685E2CA4-AA89-4574-8DB1-7C06D9F0FF2D", "versionEndExcluding": "1.0.4.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "930E739E-EFDC-49AB-9155-A71C2B25FCD6", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E02F15FF-76B1-43DD-85E0-A34E764E638D", "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "357EDE1B-75BA-4515-B0E9-2B70EF993244", "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5A09A9E8-8C77-4EDB-9483-B3C540EF083A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "839A9EBE-5F14-4695-8040-7D5607F8E248", "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EAF3EA40-79FB-4D2C-A8AF-A04820745C4D", "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AC36017-5BCF-4CF6-91D0-278279943847", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50", "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAB3F350-9094-4B64-8ED9-517069EB56F4", "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0ECEE38A-B0BB-43F8-AB4D-26572B789BFB", "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DF6302-36B7-49CF-8F2C-4C2247112EB9", "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "60634A15-B02A-4C33-A1A4-F6340CFD6B8B", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8E565CF-8408-4502-97BD-01CEF15D0744", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "609B0EC8-FCD3-4522-A06A-7CB521586A22", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8509E165-B497-4483-95E6-7BEB2AB40946", "versionEndIncluding": "1.5.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "065AE552-7268-45C5-92CA-B56602C9313D", "versionEndExcluding": "1.0.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400:v3:*:*:*:*:*:*:*", "matchCriteriaId": "1992E44C-122C-41BC-8FDC-5F9EBEE1FB7C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2FCE2862-B111-45A9-85D9-8BABEFE4F856", "versionEndExcluding": "1.2.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4AF96D62-1D28-4FE5-AFC3-FB93A1BB4D45", "versionEndExcluding": "1.0.3.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR R6400 and R6700 firmware version 1.0.4.98 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the upnpd service, which listens on UDP port 1900 by default. A crafted MX header field in an SSDP message can trigger an overflow of a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-11851." }, { "lang": "es", "value": "Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar c\u00f3digo arbitrario en las instalaciones afectadas de los enrutadores NETGEAR R6400 y R6700 versi\u00f3n de firmware 1.0.4.98.\u0026#xa0;No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad.\u0026#xa0;El fallo espec\u00edfico se presenta dentro del servicio upnpd, que escucha en el puerto UDP 1900 por defecto.\u0026#xa0;Un campo de encabezado MX dise\u00f1ado en un mensaje SSDP puede desencadenar un desbordamiento de un b\u00fafer en la regi\u00f3n stack de la memoria de longitud corregida.\u0026#xa0;Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto de root.\u0026#xa0;Era ZDI-CAN-11851" } ], "id": "CVE-2021-27239", "lastModified": "2024-11-21T05:57:39.813", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "zdi-disclosures@trendmicro.com", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-29T21:15:12.377", "references": [ { "source": "zdi-disclosures@trendmicro.com", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062820/Security-Advisory-for-Stack-based-Buffer-Overflow-Remote-Code-Execution-Vulnerability-on-Some-Routers-PSV-2020-0432" }, { "source": "zdi-disclosures@trendmicro.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-206/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062820/Security-Advisory-for-Stack-based-Buffer-Overflow-Remote-Code-Execution-Vulnerability-on-Some-Routers-PSV-2020-0432" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-206/" } ], "sourceIdentifier": "zdi-disclosures@trendmicro.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-121" } ], "source": "zdi-disclosures@trendmicro.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14440", "lastModified": "2024-11-21T05:03:16.930", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.140", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45632", "lastModified": "2024-11-21T06:32:43.787", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.277", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.0 (Critical) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbr752_firmware | * | |
netgear | rbr752 | - | |
netgear | rbr753_firmware | * | |
netgear | rbr753 | - | |
netgear | rbr753s_firmware | * | |
netgear | rbr753s | - | |
netgear | rbr754_firmware | * | |
netgear | rbr754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CCE2E74C-7472-41C9-B48B-4F6D09819694", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr752:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A727637-4CB0-4CDF-86D6-91B72E8F1A67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B8A2AE8-D24F-4FE9-BCB5-629F879CD921", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr753:-:*:*:*:*:*:*:*", "matchCriteriaId": "749C2A47-CC43-433F-8FC7-EAC9853E32AB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "725B56D3-FE36-4A77-B723-A7A3D8DD0443", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C08A0E20-90A3-4D49-8E06-97944C3EF312", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EAC29540-B53A-4033-B998-8E6BAB033FF5", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr754:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE7FE0A5-16D7-4AEC-A3B1-940F44E5492F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBR752 before 3.2.17.12, RBR753 before 3.2.17.12, RBR753S before 3.2.17.12, RBR754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autentificado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBR752 versiones anteriores a 3. 2.17.12, RBR753 versiones anteriores a 3.2.17.12, RBR753S versiones anteriores a 3.2.17.12, RBR754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29071", "lastModified": "2024-11-21T06:00:38.910", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.3, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.560", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063008/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0476" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDC785-6FEC-4D94-86D1-8E55FB0CA6C1", "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADF65DC4-51D5-4C38-B28D-7EA93B1734A3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "888A8E0F-93DD-436D-B00C-F469C3BD6E5B", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "160F53B0-8430-4D85-8ABC-0A64B27DDFBD", "versionEndExcluding": "1.0.3.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "685E2CA4-AA89-4574-8DB1-7C06D9F0FF2D", "versionEndExcluding": "1.0.4.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "10938043-F7DF-42C3-8C16-F92CAF8E5576", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "930E739E-EFDC-49AB-9155-A71C2B25FCD6", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87F3EAAB-C4C2-47BA-B87A-3CFF0C52EF21", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57A029C8-4DE3-4393-BD61-E9562C4E17D8", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5A09A9E8-8C77-4EDB-9483-B3C540EF083A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50", "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "255508E6-628A-4C83-BA39-90C9D05197B7", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35:v2:*:*:*:*:*:*:*", "matchCriteriaId": "972BB714-8869-42C6-95F6-2C15AFA65716", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68163CF2-4781-4B87-8E39-62B4DF82A44A", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40:v2:*:*:*:*:*:*:*", "matchCriteriaId": "DD5F8B3F-C0D0-496C-A235-A467EA578C28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects CBR750 before 3.2.18.2, D6220 before 1.0.0.68, D6400 before 1.0.0.102, D8500 before 1.0.3.60, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, and XR1000 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a CBR750 versiones anteriores a 3.2.18.2, D6220 versiones anteriores a 1.0.0.68, D6400 versiones anteriores a 1.0.0.102, D8500 versiones anteriores a 1.0.3.60, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0.6.116, R6300v2 versiones anteriores a 1.0.4.50, R6400 versiones anteriores a 1.0. 1.68, R6400v2 versiones anteriores a 1.0.4.118, R6700v3 versiones anteriores a 1.0.4.118, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11.116, R7000P versiones anteriores a 1.3.3.140, R7850 versiones anteriores a 1.0.5.68, R7900 versiones anteriores a 1.0.4.38, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000 versiones anteriores a 1. 0.4.68, R8000P versiones anteriores a 1.4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1. 0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80 y XR1000 versiones anteriores a 1.0.0.58" } ], "id": "CVE-2021-45604", "lastModified": "2024-11-21T06:32:38.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 2.7, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:S/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 4.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.900", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064526/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2020-0572" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064526/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-and-WiFi-Systems-PSV-2020-0572" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA48F47-FC18-4953-BA90-1F4F3695A2BE", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC9EE9DE-DD58-46A9-87FB-D284EBE0ACC1", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EB8CD19-4963-42A8-B9E6-63ED5EC35119", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0095B9D4-E161-4050-B283-2166CB86CB24", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0702F9B6-2DAC-4308-8737-9F85AD28E847", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50", "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3AE70236-D1C6-4B58-8385-1FA5F71916AF", "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA1BB56F-20B5-4A79-AE9D-429A011EAA4C", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, EAX20 versiones anteriores a 1.0.0.58, EAX80 versiones anteriores a 1.0.1.68, EX7500 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0.6.116, R6400 versiones anteriores a 1.0.1. 70, R6400v2 versiones anteriores a 1.0.4.118, R6700v3 versiones anteriores a 1.0.4.118, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11.116, R7000P versiones anteriores a 1.3.3.140, R7850 versiones anteriores a 1.0.5.68, R7900 versiones anteriores a 1.0.4.38, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000 versiones anteriores a 1.0.4. 68, R8000P versiones anteriores a 1.4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4. 120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80, XR1000 versiones anteriores a 1.0.0.58 y XR300 versiones anteriores a 1.0.3.68" } ], "id": "CVE-2021-45622", "lastModified": "2024-11-21T06:32:42.160", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.810", "references": [ { "source": "cve@mitre.org", "tags": [ "Broken Link" ], "url": "https://kb.netgear.com/000064509/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extender-WiFi-Systems-PSV-2020-0506" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://kb.netgear.com/000064509/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extender-WiFi-Systems-PSV-2020-0506" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45599", "lastModified": "2024-11-21T06:32:37.853", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.667", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064145/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0546" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064145/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0546" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45564", "lastModified": "2024-11-21T06:32:32.060", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.040", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064085/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0067" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064085/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0067" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14437", "lastModified": "2024-11-21T05:03:16.423", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.860", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061940/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0054" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbs840v_firmware | * | |
netgear | rbs840v | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7001C735-233D-49D6-8289-38E5CCE6E8BA", "versionEndExcluding": "2.5.0.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5C6DF5F-FEFB-4A30-87CC-379E726AE181", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "451C5603-927A-4EB9-BF9D-150FE16A48F8", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B22B149-BD16-42A0-BB1D-DEF483F6B5E1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3C62A0E-8B8F-49BE-B953-E6C0D293ED55", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840v:-:*:*:*:*:*:*:*", "matchCriteriaId": "2C720141-11EF-4BBC-B74D-986BC36518B4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.14, RBW30 versiones anteriores a 2.6.1.4, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK842 versiones anteriores a 3.2.16.6, RBR840 versiones anteriores a 3.2.16.6, RBS840 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4." } ], "id": "CVE-2020-35802", "lastModified": "2024-11-21T05:28:09.167", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.517", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45591", "lastModified": "2024-11-21T06:32:36.560", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.300", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064113/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0099" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064113/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0099" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "930E739E-EFDC-49AB-9155-A71C2B25FCD6", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "839A9EBE-5F14-4695-8040-7D5607F8E248", "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EAF3EA40-79FB-4D2C-A8AF-A04820745C4D", "versionEndExcluding": "1.3.2.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F5A371E-41CA-4C5A-8DDC-3BD197F49096", "versionEndExcluding": "1.0.4.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3AE70236-D1C6-4B58-8385-1FA5F71916AF", "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "525B767F-5A8A-4E6C-8585-BCBB05948B2D", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A95F7AFD-13E8-49B7-BA80-D8BC61C254FE", "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AA18981F-7951-4BD5-9471-B4CD0D51D20B", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3C502A5-DE6F-4807-817C-7D097D4058A6", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A33291E-18F7-452C-A5EF-7B3C2D087704", "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6233EAE2-4B6F-417A-84DB-32F2D2B8316E", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B1506EC-709B-4A5D-9CA9-4038C5F0B150", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "312443FE-741B-4D78-8ACE-B21758D34769", "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23F1DF08-6E1C-43F5-A7F4-98A3C4B3ACE0", "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C2D9DA7-7408-4076-B596-5ADB2E990FA3", "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "430F3059-40B9-45DC-B62B-2C657478CA3E", "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C44212CB-5096-4330-A252-E0A1D9E0D291", "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2E64953-F629-462E-AE4B-30DE927FBFF1", "versionEndExcluding": "3.2.16.22", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX7500 before 1.0.0.72, R6400 before 1.0.1.68, R6900P before 1.3.2.132, R7000 before 1.0.11.116, R7000P before 1.3.2.132, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, RAX200 before 1.0.3.106, RS400 before 1.5.1.80, XR300 before 1.0.3.68, MK62 before 1.0.6.110, MR60 before 1.0.6.110, R6400v2 before 1.0.4.106, R8000P before 1.4.1.66, RAX20 before 1.0.2.64, RAX45 before 1.0.2.82, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, R6700v3 before 1.0.4.106, R7900P before 1.4.1.66, RAX15 before 1.0.2.64, RAX50 before 1.0.2.82, RAX75 before 1.0.3.106, RBR750 before 3.2.16.22, RBR850 before 3.2.16.22, RBS750 before 3.2.16.22, RBS850 before 3.2.16.22, RBK752 before 3.2.16.22, and RBK852 before 3.2.16.22." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX7500 versiones anteriores a 1.0.0.72, R6400 versiones anteriores a 1.0.1.68, R6900P versiones anteriores a 1.3.2.132, R7000 versiones anteriores a 1.0.11.116, R7000P versiones anteriores a 1.3.2. 132, R7900 versiones anteriores a 1.0.4.38, R7960P versiones anteriores a 1.4.1.66, R8000 versiones anteriores a 1.0.4.66, RAX200 versiones anteriores a 1.0.3.106, RS400 versiones anteriores a 1.5.1.80, XR300 versiones anteriores a 1.0.3.68, MK62 versiones anteriores a 1.0.6.110, MR60 versiones anteriores a 1.0.6.110, R6400v2 versiones anteriores a 1. 0.4.106, R8000P versiones anteriores a 1.4.1.66, RAX20 versiones anteriores a 1.0.2.64, RAX45 versiones anteriores a 1.0.2.82, RAX80 versiones anteriores a 1.0.3.106, MS60 versiones anteriores a 1.0.6.110, R6700v3 versiones anteriores a 1.0.4.106, R7900P versiones anteriores a 1.4.1.66, RAX15 versiones anteriores a 1.0.2. 64, RAX50 versiones anteriores a 1.0.2.82, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.22, RBR850 versiones anteriores a 3.2.16.22, RBS750 versiones anteriores a 3.2.16.22, RBS850 versiones anteriores a 3.2.16.22, RBK752 versiones anteriores a 3.2.16.22 y RBK852 versiones anteriores a 3.2.16.22" } ], "id": "CVE-2021-45617", "lastModified": "2024-11-21T06:32:41.140", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.567", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064505/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0156" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064505/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0156" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26928", "lastModified": "2024-11-21T05:20:31.087", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:18.403", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062324/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0027" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062324/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0027" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45592", "lastModified": "2024-11-21T06:32:36.713", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.347", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064114/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0100" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064114/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0100" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E99E8C5-D88D-409C-8233-944E254D587F", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5A09A9E8-8C77-4EDB-9483-B3C540EF083A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B80222E-C65C-4AA5-9399-E2017D844117", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D208F2CA-DB20-4C82-8FFF-B99EBFE29713", "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5A29C8A-71C1-477F-9D17-CD2E74784BB8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:*:*:*:*:*:*:*:*", "matchCriteriaId": "3524A509-D0CF-40EB-93FE-9538169CEF53", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:*:*:*:*:*:*:*:*", "matchCriteriaId": "8DC381A4-BDC7-4F40-AD68-F9EEE5370AC1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9800CB2-C14A-406B-B1FF-B1B62862EBDB", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F35362B-CF27-4C04-AD15-8579F1F6B949", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4171EB00-3664-43D5-9B62-A3538C358142", "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:*:*:*:*:*:*:*:*", "matchCriteriaId": "7780F243-8E08-4E1F-A819-24386B05F817", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F030129E-95C6-4C31-92A6-DABCDC1B534B", "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:*:*:*:*:*:*:*:*", "matchCriteriaId": "41BA56D3-4429-43DA-9988-A83CC92D323D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "921A8CFC-D86E-4674-998E-31F4F956B5DC", "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE56058F-FE7A-43D3-A362-2043B74FAE81", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "478CE991-5E30-438D-94B0-0E15A29E27BD", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:*:*:*:*:*:*:*:*", "matchCriteriaId": "09DF14C8-CE32-47AB-B087-D8D6C84C8F98", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "19D625E4-17F4-44EF-9A51-DA0BAD4835F2", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0D05E55-6C70-419A-9A5D-D89AA8F19499", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1D59AC0-2859-46C0-B050-3BB8E3E9CB06", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5B64473-5409-419B-967A-E4D7922D7010", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "99DA73AE-E82E-4886-9237-291B6B32BE9E", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk60:*:*:*:*:*:*:*:*", "matchCriteriaId": "F2581D68-BF67-43E9-9465-A510DC80C236", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:*:*:*:*:*:*:*:*", "matchCriteriaId": "D651DEF9-CC2F-4ADB-9FEE-5C43A8366A75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:*:*:*:*:*:*:*:*", "matchCriteriaId": "7467498D-EEFE-4B57-8031-B9F99751D556", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACAD2041-9A20-444A-BB81-8764610D6F00", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B377E02-0228-4A2F-90F3-A82E7E964B37", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:*:*:*:*:*:*:*:*", "matchCriteriaId": "2982807D-D17B-49B8-B0D7-80662EDFC306", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA8D0327-0A72-44EC-9CC2-6CAF6A0C08B2", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C64BD39-F245-47DB-981D-36613AD40BFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44537647-E0B2-477D-98A5-7EA850BF3321", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:*:*:*:*:*:*:*:*", "matchCriteriaId": "67C27B00-2FD3-4AE9-90B7-AEFA2631C9E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:*:*:*:*:*:*:*:*", "matchCriteriaId": "3DED03C1-00A1-49B3-BD19-DCCC489E7FE2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:*:*:*:*:*:*:*:*", "matchCriteriaId": "B881D3AF-6D5B-4AC9-BB36-E673D88BDC54", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCF91BA6-DF2A-4121-9246-83C6DAA89C11", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4EAEF0F-DCED-4ECC-B8DF-4E91AA030D8E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49D5D1E8-637A-4970-8753-6A3FCA8FAC64", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:*:*:*:*:*:*:*:*", "matchCriteriaId": "497D21B1-4F55-408F-8D05-18B2B9F55291", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A3B894E-E712-477A-9960-30AFAB2C35CF", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:*:*:*:*:*:*:*:*", "matchCriteriaId": "80FD45DF-A29E-46C7-99DC-09EE74F5A276", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71AE85C-74C4-42C1-BF54-89B6EC38C707", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:*:*:*:*:*:*:*:*", "matchCriteriaId": "12DA6A42-4064-4884-9D8C-7273CA8F0498", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B59B0C17-2714-48E8-8911-E72488CE32E3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:*:*:*:*:*:*:*:*", "matchCriteriaId": "111905EF-0E9E-4321-837F-D7E7C146E9FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:*:*:*:*:*:*:*:*", "matchCriteriaId": "06EC4DE7-7424-4D7C-9979-88C58CBB0978", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:*:*:*:*:*:*:*:*", "matchCriteriaId": "24022452-B0A3-4101-875A-46D0B5E60D48", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:*:*:*:*:*:*:*:*", "matchCriteriaId": "31427F8E-7D14-4DE1-AF03-7487073040B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E391711-0D34-4CBB-9022-BF809C435616", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:*:*:*:*:*:*:*:*", "matchCriteriaId": "57204B6D-6D87-4616-91ED-446894C24A3A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C348EA7B-1226-4745-9961-A5B253BE8235", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:*:*:*:*:*:*:*:*", "matchCriteriaId": "DFFAC263-BF84-404C-9A4F-BF9D1D4134E5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "85D95CCB-7E4A-4CA5-A503-FB79DBC08DDE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:*:*:*:*:*:*:*:*", "matchCriteriaId": "2731D467-A9C2-4801-9D41-BBECF0F4C585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:*:*:*:*:*:*:*:*", "matchCriteriaId": "C6CB2B42-ADFE-42A7-8A9D-B5C2ED6F2E7F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB5309A5-3F84-46F4-BB50-754E9C52FA88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B06308A-9862-4B1E-A100-B9A8B47311B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02781FF1-A884-44D3-8364-FF8371D47FCA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:*:*:*:*:*:*:*:*", "matchCriteriaId": "530F895F-0061-441F-A2BD-CC51A8C13BE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FAA417FF-DB33-477B-9D73-003CE56C5D78", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9217A7B-0410-4E57-BD91-8E20237FB52B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:*:*:*:*:*:*:*:*", "matchCriteriaId": "A77C093D-AF25-4757-880C-698A7902D507", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A92FEE8-77A2-49DE-BCF7-9416F64E5F28", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5C6DF5F-FEFB-4A30-87CC-379E726AE181", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AC8A705-F376-4B1F-B5AD-024CE43EB997", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "451C5603-927A-4EB9-BF9D-150FE16A48F8", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:*:*:*:*:*:*:*:*", "matchCriteriaId": "057CD043-7ACD-4284-9CC0-171F437B1501", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B22B149-BD16-42A0-BB1D-DEF483F6B5E1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D633C05-5C85-490D-8692-BBA04C36F450", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F898DC9-9250-47DF-844C-F7308365135B", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1B44D10-8A75-4643-8937-9157C7C1014D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0754CB8B-A9D4-4444-8426-E1DDBBD2A9D1", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:*:*:*:*:*:*:*:*", "matchCriteriaId": "D00B9746-B4B1-4473-8417-BF1B10831B50", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D35F61B-5E8F-483B-9F31-A312AB8C717F", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8C14B49-D069-41E3-94C3-A49E06022D60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23D4F7E6-C042-434E-87B8-55DB18B08B0A", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6260:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E2353F3-A93F-4477-9E2E-4E23EAA5F51C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3408536D-FC77-48C5-AD15-C5A170D7417C", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6850:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4F77BFF-3640-4906-ABCF-E3C6945050E3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F105F6F-ECD3-411D-924E-94BCF036C1EA", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6350:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B54BEAD-CF85-48AB-87EE-F09FAAF1F3D6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6524B85E-23AC-4983-8331-96E12899B773", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6330:*:*:*:*:*:*:*:*", "matchCriteriaId": "D552EC52-5DB8-45BF-BD1B-0554FCEBCD24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACEAC1F2-EEAE-4880-B6C0-FFAAA29685F1", "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C82317F-0843-4B4F-9FE0-8A44BA651D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E3BFCB-BFF8-4722-BE48-5FA93CACD3AD", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:*:*:*:*:*:*:*:*", "matchCriteriaId": "4660355E-74B6-40E5-86E0-3BA55589C557", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "39D6318D-F5A2-4469-B508-075F2825F0FA", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D9688E5-D944-437C-81AC-03CA64087DC3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F44708A-C946-4E0F-9D6C-A91AFB4C9EF3", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:*:*:*:*:*:*:*:*", "matchCriteriaId": "00C4E1D7-94CB-4A0B-9E74-89880CBFF11C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAC56D3D-B697-4C9D-ADBB-A45845A3B5D4", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:*:*:*:*:*:*:*:*", "matchCriteriaId": "AADEEDB6-C8F5-41D3-93C8-AB94605554C9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E21623E-9977-486F-93B1-858FC407E9D1", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:*:*:*:*:*:*:*:*", "matchCriteriaId": "5428D4B4-DEEC-4A14-BF24-EB480A614FA8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A32769CF-7D0A-4A3F-AF20-6202CA0C6870", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:*:*:*:*:*:*:*:*", "matchCriteriaId": "772CF322-9944-4243-BFBB-8F133AE5A373", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk23_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "675E9C59-D39B-47B0-ABEC-32D548650AB7", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk23:*:*:*:*:*:*:*:*", "matchCriteriaId": "752FA3EA-C87D-4402-ACFF-11E1DE15501B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1612C65-9BA0-4CAF-93B3-D528287B0790", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE1E01AE-DE82-4F20-BCFB-E5A48CCE28AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04F03BE5-1440-4BC4-B902-97E702ED0ADF", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:*:*:*:*:*:*:*:*", "matchCriteriaId": "B12E8664-5D49-4377-A8C4-175F15E94083", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EC30751-F447-45A7-8C57-B73042869EA5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk12:*:*:*:*:*:*:*:*", "matchCriteriaId": "D26AB2BC-061D-4142-9E37-A22368398876", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk13_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E7758BF-0AE4-46DB-A014-734F68AEEAA0", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk13:*:*:*:*:*:*:*:*", "matchCriteriaId": "52BB59CE-7024-4F7C-B49B-C2444FAA923E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk14_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B7CD38DB-B4A3-460E-8F89-E85A0E0F5BD3", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk14:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0CD88D0-E4F4-4695-A2BE-44758F6CA4C4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E25990D-C38A-44E7-A301-AB9E80A9D5CA", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk15:*:*:*:*:*:*:*:*", "matchCriteriaId": "87232E4A-7821-4A7A-8D31-67C91DCCA5B2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8246B8D3-8455-43B1-B0FA-F677B8FF84F5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr10:*:*:*:*:*:*:*:*", "matchCriteriaId": "69E984D9-C35E-4925-A3C3-695BCEF56C75", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28DA498C-B466-422E-BAD2-A1F9A15B157F", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs10:*:*:*:*:*:*:*:*", "matchCriteriaId": "B0242C44-637E-4984-B830-9148E265E74B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8956A99-1071-42A7-8984-D7134E755CBF", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F3127F5-9624-4002-B8F8-D76A01676ADA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A660042D-27F6-4110-AB03-BCAFAC194557", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFA2C5B9-92C2-4E70-B166-87AD9973F80E", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02279B20-D951-46CE-B339-452BC585A4F3", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7200:*:*:*:*:*:*:*:*", "matchCriteriaId": "E330A8C5-1D91-4743-A35C-430CB5EAA0A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B452611A-43C5-401B-95BD-189020B5C65C", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7350:*:*:*:*:*:*:*:*", "matchCriteriaId": "F27FB281-6C22-45E6-A3A1-DE90C3F2B608", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "237C68C0-C2A9-4F71-9E08-547F2A317CBC", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7400:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE8F6B4F-5995-40A4-89B4-325BACA086A2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63697E3A-AAA3-42E7-8116-93C6548D3AB7", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7450:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB5E5161-10A9-41A9-9FC4-9A5F6B4536AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C1280B1-A2DF-4CAB-AB19-6B463206AA3D", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2100:*:*:*:*:*:*:*:*", "matchCriteriaId": "DDFA0025-8657-4A20-A282-D1034D8BBEF3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76C658A4-BF82-40CE-A5E1-C9F3DA1A9B0B", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2400:*:*:*:*:*:*:*:*", "matchCriteriaId": "710011A1-F633-4B5D-9C09-04E518C71DE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A3A6655-B468-46FB-84D7-2294D4243C91", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2600:*:*:*:*:*:*:*:*", "matchCriteriaId": "474A7CEB-7133-40FA-8FC5-BC85D712DABF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C393DBF4-8281-4611-B591-CDB9DF0AA958", "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:*:*:*:*:*:*:*:*", "matchCriteriaId": "01CF301B-9DF5-4960-BD62-06E56EDF1031", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57314D03-64B1-4973-9D36-5D22A71DBCBB", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CD4841B-0F5C-4B7B-9764-F37605BF7AD9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DCE56F2-5A45-4B31-99EF-1D8455C71E5C", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4AAEB70-4F97-4044-B897-86020787DE01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B697A877-214C-4701-AA9B-FE9C23FDBCEB", "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:*:*:*:*:*:*:*:*", "matchCriteriaId": "B302272A-8BCE-47B7-B7DB-026B22A39367", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "051E8D2A-0EB0-43A7-9AAA-8519B8CC7FE0", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA83AEEB-FBEB-40A9-9F61-814596C00922", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BCFB551-95C6-4EEF-83F0-4246F67E6668", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F284951-6DAA-4AA4-A189-44CDB44878A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89AB672D-DD24-483E-B69D-7E46AF199483", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AF919EF-8893-4E1A-A854-3FB932682504", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:*:*:*:*:*:*:*:*", "matchCriteriaId": "AED2DE10-EC70-4A50-9C17-2C02569BD149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta al R6700v3 versiones anteriores a 1.0.4.98, al R6400v2 versiones anteriores a 1.0.4.98, al R7000 versiones anteriores a 1.0.11.106, al R6900P versiones anteriores a 1.3.2.124, al R7000P versiones anteriores a 1.3.2.124, al R7900 versiones anteriores a 1.0.4.26, al R7850 versiones anteriores a 1.0.5.60, al R8000 versiones anteriores a 1.0.4.58, al RS400 versiones anteriores a 1.5.0.48, al R6400 versiones anteriores a 1.0.1. 62, R6700 versiones anteriores a 1.0.2.16, R6900 versiones anteriores a 1.0.2.16, MK60 versiones anteriores a 1.0.5.102, MR60 versiones anteriores a 1.0.5.102, MS60 versiones anteriores a 1.0.5.102, CBR40 versiones anteriores a 2.5.0.10, R8000P versiones anteriores a 1.4.1.62, R7960P versiones anteriores a 1.4.1.62, R7900P versiones anteriores a 1.4.1.62, RAX15 versiones anteriores a 1.0.1.64, RAX20 versiones anteriores a 1. 0.1.64, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102, RAX200 versiones anteriores a 1.0.2.102, RAX45 versiones anteriores a 1.0.2.64, RAX50 versiones anteriores a 1.0.2.64, EX7500 versiones anteriores a 1.0.0.68, EAX80 versiones anteriores a 1.0.1.62, EAX20 versiones anteriores a 1.0.0.36, RBK752 versiones anteriores a 3.2.16.6, RBK753 versiones anteriores a 3.2.16. 6, RBK753S versiones anteriores a 3.2.16.6, RBK754 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16. 6, RBK853 versiones anteriores a 3.2.16.6, RBK854 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBR840 versiones anteriores a 3.2.16. 6, RBS840 versiones anteriores a 3.2.16.6, R6120 versiones anteriores a 1.0.0.70, R6220 versiones anteriores a 1.1.0.100, R6230 versiones anteriores a 1.1.0.100, R6260 versiones anteriores a 1.1.0.76, R6850 versiones anteriores a 1.1.0.76, R6350 versiones anteriores a 1.1.0.76, R6330 versiones anteriores a 1.1.0.76, D7800 versiones anteriores a 1.0.1.58, RBK50 versiones anteriores a 2.6.1.40, RBR50 versiones anteriores a 2. 6.1.40, RBS50 versiones anteriores a 2.6.1.40, RBK40 versiones anteriores a 2.6.1.36, RBR40 versiones anteriores a 2.6.1.36, RBS40 versiones anteriores a 2.6.1.38, RBK23 versiones anteriores a 2.6.1.36, RBR20 versiones anteriores a 2.6.1.38, RBS20 versiones anteriores a 2.6.1.38, RBK12 versiones anteriores a 2.6.1.44, RBK13 versiones anteriores a 2.6.1.44, RBK14 versiones anteriores a 2.6.1. 44, RBK15 versiones anteriores a 2.6.1.44, RBR10 versiones anteriores a 2.6.1.44, RBS10 versiones anteriores a 2.6.1.44, R6800 versiones anteriores a 1.2.0.72, R6900v2 versiones anteriores a 1.2.0. 72, R6700v2 versiones anteriores a 1.2.0.72, R7200 versiones anteriores a 1.2.0.72, R7350 versiones anteriores a 1.2.0.72, R7400 versiones anteriores a 1.2.0.72, R7450 versiones anteriores a 1.2.0.72, AC2100 versiones anteriores a 1. 2.0.72, AC2400 versiones anteriores a 1.2.0.72, AC2600 versiones anteriores a 1.2.0.72, R7800 versiones anteriores a 1.0.2.74, R8900 versiones anteriores a 1.0.5.24, R9000 versiones anteriores a 1.0.5.24, RAX120 versiones anteriores a 1.0.1.136, XR450 versiones anteriores a 2.3.2.66, XR500 versiones anteriores a 2.3.2.66, XR700 versiones anteriores a 1.0.1.34 y XR300 versiones anteriores a 1.0.3.50" } ], "id": "CVE-2021-29068", "lastModified": "2024-11-21T06:00:38.353", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.9, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.297", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | rax20_firmware | * | |
netgear | rax20 | - | |
netgear | rax45_firmware | * | |
netgear | rax45 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rax15_firmware | * | |
netgear | rax15 | - | |
netgear | rax50_firmware | * | |
netgear | rax50 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | eax80_firmware | * | |
netgear | eax80 | - | |
netgear | ex7500_firmware | * | |
netgear | ex7500 | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX80 versiones anteriores a 1.0.1.62, EX7500 versiones anteriores a 1.0.0.72, R7900 versiones anteriores a 1.0.4.38, R8000 versiones anteriores a 1.0.4. 68, RAX200 versiones anteriores a 1.0.4.120, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, MR60 versiones anteriores a 1.0.6.110, RAX20 versiones anteriores a 1.0.2.82, RAX45 versiones anteriores a 1.0.2. 72, RAX80 versiones anteriores a 1.0.4.120, MS60 versiones anteriores a 1.0.6.110, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1.0.2.72, RAX75 versiones anteriores a 1.0.4.120, RBR750 versiones anteriores a 3. 2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45671", "lastModified": "2024-11-21T06:32:50.550", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.7, "impactScore": 5.3, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:21.057", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta al RBK852 versiones anteriores a 3.2.17.12, al RBK853 versiones anteriores a 3.2.17.12, al RBK854 versiones anteriores a 3.2.17.12, al RBR850 versiones anteriores a 3.2.17.12 y al RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29066", "lastModified": "2024-11-21T06:00:37.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.157", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063014/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0484" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45587", "lastModified": "2024-11-21T06:32:35.937", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.117", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | rax20_firmware | * | |
netgear | rax20 | - | |
netgear | rax45_firmware | * | |
netgear | rax45 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rax15_firmware | * | |
netgear | rax15 | - | |
netgear | rax50_firmware | * | |
netgear | rax50 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a RAX200 versiones anteriores a 1.0.3.106, al MR60 versiones anteriores a 1.0.6.110, a RAX20 versiones anteriores a 1.0.2.82, a RAX45 versiones anteriores a 1.0.2.72, a RAX80 versiones anteriores a 1.0.3.106, al MS60 versiones anteriores a 1.0.6.110, a RAX15 versiones anteriores a 1.0.2.82, a RAX50 versiones anteriores a 1.0.2.72, a RBK752 versiones anteriores a 3.2.16.6 y a RBK852 versiones anteriores a 3.2.16.6. 0.2.72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6." } ], "id": "CVE-2021-45669", "lastModified": "2024-11-21T06:32:50.190", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 3.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 0.7, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:20.960", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rbk752 | - | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.3.106, RAX80 before 1.0.3.106, RAX75 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RAX200 versiones anteriores a 1.0.3.106, RAX80 versiones anteriores a 1.0.3.106, RAX75 versiones anteriores a 1.0.3.106, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45535", "lastModified": "2024-11-21T06:32:26.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.647", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064457/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0052" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064457/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0052" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | d7000v2_firmware | * | |
netgear | d7000v2 | - | |
netgear | lax20_firmware | * | |
netgear | lax20 | - | |
netgear | mk62_firmware | * | |
netgear | mk62 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rax15_firmware | * | |
netgear | rax15 | - | |
netgear | rax20_firmware | * | |
netgear | rax20 | - | |
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax45_firmware | * | |
netgear | rax45 | - | |
netgear | rax50_firmware | * | |
netgear | rax50 | - | |
netgear | rax43_firmware | * | |
netgear | rax43 | - | |
netgear | rax40v2_firmware | * | |
netgear | rax40v2 | - | |
netgear | rax35v2_firmware | * | |
netgear | rax35v2 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | xr1000_firmware | * | |
netgear | xr1000 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C2D1C234-22F1-4837-9D04-059170A97072", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D7000v2 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0.6. 116, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3. 96, RAX40v2 versiones anteriores a 1.0.3.96, RAX35v2 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3. 2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12 y XR1000 versiones anteriores a 1.0.0.58" } ], "id": "CVE-2021-45614", "lastModified": "2024-11-21T06:32:40.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.427", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0520" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064141/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0520" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26903", "lastModified": "2024-11-21T05:20:27.257", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:15.807", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062351/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0043" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062351/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0043" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45505", "lastModified": "2024-11-21T06:32:22.110", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.133", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064129/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0477" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064129/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0477" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25 y RBS840 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14434", "lastModified": "2024-11-21T05:03:15.850", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "COMPLETE", "baseScore": 7.7, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.547", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26904", "lastModified": "2024-11-21T05:20:27.410", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:16.107", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062350/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0046" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062350/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0046" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26906", "lastModified": "2024-11-21T05:20:27.713", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:16.463", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062348/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0048" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062348/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0048" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45589", "lastModified": "2024-11-21T06:32:36.263", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.210", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064111/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0097" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064111/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0097" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14439", "lastModified": "2024-11-21T05:03:16.763", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:13.047", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061942/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0064" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por un usuario autenticado. Esto afecta a RAX200 versiones anteriores a 1.0.4.120, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-38518", "lastModified": "2024-11-21T06:17:18.670", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.2, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-11T00:15:35.397", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063783/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0528" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45590", "lastModified": "2024-11-21T06:32:36.403", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.257", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0098" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064112/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0098" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45558", "lastModified": "2024-11-21T06:32:30.990", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.757", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45567", "lastModified": "2024-11-21T06:32:32.560", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.177", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064089/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0075" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064089/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0075" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14430", "lastModified": "2024-11-21T05:03:15.150", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.170", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26897", "lastModified": "2024-11-21T05:20:26.343", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:12.450", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062357/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0045" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062357/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0045" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45571", "lastModified": "2024-11-21T06:32:33.220", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.370", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064093/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0079" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064093/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0079" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F36AC74-11DB-4805-9B73-302F86A8C240", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E84B61C3-54CA-4127-AE6B-E63AB51E0C85", "versionEndExcluding": "1.0.0.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A0D49BA-4843-4F7E-984A-FF7BDF292F56", "versionEndExcluding": "1.0.0.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000:v2:*:*:*:*:*:*:*", "matchCriteriaId": "D8780623-F362-4FA5-8B33-37E9CB3FEE12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0A6C9089-563D-4345-90C7-D2D512382BF1", "versionEndExcluding": "1.0.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6DF302FA-84AA-4863-B30F-7E4364CD098C", "versionEndExcluding": "1.0.3.43", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7587473-93CA-4998-9D73-0E936E425F23", "versionEndExcluding": "1.0.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "373DD028-D307-4B4A-9C35-DDC9366F481F", "versionEndExcluding": "1.0.0.108", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200:v4:*:*:*:*:*:*:*", "matchCriteriaId": "099184A0-F1C6-4C3F-9C3B-F0B9AC0D4D14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA9F2B44-4114-495A-B200-B703FDFC3F8F", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A25B8627-D325-493B-8B7D-4F900334F0D8", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81ED6C61-2A7C-49EC-BD3D-466442EF715C", "versionEndExcluding": "2.3.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "448D7EA1-A7BB-4AA5-8260-1D533D6A99AC", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1525B9D0-B147-437D-ACAE-58819A1F4FC6", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4515F985-B714-480C-8FBA-2499A29F29FA", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CC5263E-71E4-4B63-AD77-D1E72DC704B0", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D130E198-E9F5-4250-9C52-E39DF5C96711", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08426AC6-4811-43E8-87EB-204A2729C49B", "versionEndExcluding": "2.3.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6020_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "973CBC26-395C-407F-937B-4E9D2DBE282C", "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6020:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DDA7ABF-4C4B-4945-993A-F93BD8FCB55E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6080_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "38FE855A-C695-4D0B-98C8-1D09265F0092", "versionEndExcluding": "1.0.0.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6080:-:*:*:*:*:*:*:*", "matchCriteriaId": "1CEB5C49-53CF-44AE-9A7D-E7E6201BFE62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A26A8815-5A8C-499B-8B30-90ADA47DA3C6", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "220EBC67-69DA-43D6-8B09-EBEEEF29679D", "versionEndExcluding": "1.1.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9466A450-0351-4B2D-B816-6A1B6F4F34B9", "versionEndExcluding": "1.1.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "matchCriteriaId": "C91CADFA-59DB-4B6C-A914-848884F4A4BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1DD1F7D-7556-4B95-A33F-E389948D20AA", "versionEndExcluding": "1.0.4.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF20BDF1-ADE3-4C82-8E11-C720DA0BCD26", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "matchCriteriaId": "3C395D49-57F9-4BC1-8619-57127355B86B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0BC2E51-CD2D-43F2-B4BF-D2487673487D", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", "matchCriteriaId": "598B48C5-4706-4431-8C5A-DA496DD1052F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "256D5AB2-9B04-4569-84F3-ACA6B8283176", "versionEndExcluding": "1.1.0.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B302909-29CF-4E53-9CCB-8664D3FCB03A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91532716-831D-401C-8707-86785F0A4E16", "versionEndExcluding": "1.0.2.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "52AE9AD2-BC8D-477D-A3D3-891AE52FA5F3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "73CE0588-37C3-48C1-B013-3277CCE4EF98", "versionEndExcluding": "1.0.2.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v3:*:*:*:*:*:*:*", "matchCriteriaId": "5A09A9E8-8C77-4EDB-9483-B3C540EF083A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A4FB8A1-D380-4234-88EB-91BFF6D215C7", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700:v2:*:*:*:*:*:*:*", "matchCriteriaId": "9F9706E6-CA53-43E4-91B0-D52655C86860", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3C39CE79-6433-47E2-A439-9AB1DFBD843C", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB6992BA-B0F5-4E00-84F4-0B0336910AFA", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E8EB69B-6619-47B6-A073-D0B840D4EB0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E453D3AE-A218-4791-BB19-79C2CF6EC6F8", "versionEndExcluding": "1.0.9.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52A6DEB2-3A33-4184-866D-9C8D9DD991C6", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90805FFE-E59D-43D2-BF1E-D55458CF05BF", "versionEndExcluding": "1.3.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B484FA9-17B9-4829-9152-83691EE6A9BB", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6DC5CA05-2101-4C3A-9E04-D977EBEA9B0B", "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", "matchCriteriaId": "FECB83F9-D417-4FD3-B293-87BC177E3AEB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E355B76-0211-452E-8A1B-F5C7B8CD4782", "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFD1A65C-F10F-4C52-8B6D-69992E512EB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08D8DE61-6C45-48DC-9914-10CDB3273FFA", "versionEndExcluding": "1.2.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F68AC3B-A31F-4AB0-89E9-BFFDE427AD3B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "153A698C-B517-4B5B-B7AB-D2A50F461213", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DA5420D-DD64-4A9C-9B5F-784F0ED2B464", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E46DF93A-4331-4AC2-A45F-7A729441C395", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", "matchCriteriaId": "A80B06A1-81B5-4C33-89F6-EC3F6E3068B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE12CDFB-D0CD-451A-A52F-90F907ADDAEF", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B25A18F-DD96-45FE-B098-71E60CB0FFFE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "38297D93-B613-4E6C-9C35-2C3A45E72A2F", "versionEndExcluding": "1.2.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BFCD9A8-1846-48C4-9F14-3866E983FB74", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "536487B8-FF04-4526-BE91-44437256525C", "versionEndExcluding": "1.0.3.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*", "matchCriteriaId": "2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F9D54BE2-47EB-48F1-A6D0-FB0A2F5094C4", "versionEndExcluding": "1.0.2.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845CF217-8361-4D5B-811D-B9CEB68880CB", "versionEndExcluding": "1.0.3.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "24B5561C-CB98-45BE-A39D-0C1CD8DFFA1A", "versionEndExcluding": "1.4.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "98FAEBDA-5FBA-402D-9BA1-25E5DF4EF55F", "versionEndExcluding": "1.0.4.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8BBB7E16-D31C-49EA-9D82-D3BACED95441", "versionEndExcluding": "1.4.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6791754E-E5F9-42EA-AFDA-F93E8227A7C8", "versionEndExcluding": "1.4.1.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F52E74FF-6E04-4F96-966C-4355B38CF4DE", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2110965C-E19B-48D2-954D-145C45D0E7EF", "versionEndExcluding": "1.0.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79E7E940-B043-40A7-9347-331DF006656E", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr3500l_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0960178A-5EC8-4C53-8AA2-060025782DC0", "versionEndExcluding": "1.2.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr3500l:v2:*:*:*:*:*:*:*", "matchCriteriaId": "C8DE4BFA-41DE-4748-ACC7-14362333A059", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "804E18F1-4621-4650-9015-49A9137A0C39", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29216B3A-9A3B-4752-99C2-4A9CFA8E5E26", "versionEndExcluding": "2.3.2.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by lack of access control at the function level. This affects D6220 before 1.0.0.48, D6400 before 1.0.0.82, D7000v2 before 1.0.0.52, D7800 before 1.0.1.44, D8500 before 1.0.3.43, DC112A before 1.0.0.40, DGN2200v4 before 1.0.0.108, RBK50 before 2.3.0.32, RBR50 before 2.3.0.32, RBS50 before 2.3.0.32, RBK20 before 2.3.0.28, RBR20 before 2.3.0.28, RBS20 before 2.3.0.28, RBK40 before 2.3.0.28, RBR40 before 2.3.0.28, RBS40 before 2.3.0.28, R6020 before 1.0.0.34, R6080 before 1.0.0.34, R6120 before 1.0.0.44, R6220 before 1.1.0.80, R6230 before 1.1.0.80, R6250 before 1.0.4.34, R6260 before 1.1.0.40, R6850 before 1.1.0.40, R6350 before 1.1.0.40, R6400v2 before 1.0.2.62, R6700v3 before 1.0.2.62, R6700v2 before 1.2.0.36, R6800 before 1.2.0.36, R6900v2 before 1.2.0.36, R7000 before 1.0.9.34, R6900P before 1.3.1.44, R7000P before 1.3.1.44, R7100LG before 1.0.0.48, R7200 before 1.2.0.48, R7350 before 1.2.0.48, R7400 before 1.2.0.48, R7450 before 1.2.0.36, AC2100 before 1.2.0.36, AC2400 before 1.2.0.36, AC2600 before 1.2.0.36, R7500v2 before 1.0.3.38, R7800 before 1.0.2.58, R7900 before 1.0.3.8, R7960P before 1.4.1.44, R8000 before 1.0.4.28, R7900P before 1.4.1.30, R8000P before 1.4.1.30, R8900 before 1.0.4.2, R9000 before 1.0.4.2, RAX120 before 1.0.0.74, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, WNR3500Lv2 before 1.2.0.56, XR450 before 2.3.2.32, and XR500 before 2.3.2.32." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una falta de control de acceso a nivel de funci\u00f3n. Esto afecta a D6220 versiones anteriores a 1.0.0.48, D6400 versiones anteriores a 1.0.0.82, D7000v2 versiones anteriores a 1.0.0.52, D7800 versiones anteriores a 1.0.1.44, D8500 versiones anteriores a 1.0.3.43, DC112A versiones anteriores a 1.0.0.40, DGN2200v4 versiones anteriores a 1.0.0.108, RBK50 versiones anteriores a 2.3.0.32, RBR50 versiones anteriores a 2.3.0.32, RBS50 versiones anteriores a 2.3.0.32, RBK20 versiones anteriores a 2.3.0.28, RBR20 versiones anteriores a 2.3.0.28, RBS20 versiones anteriores a 2.3.0.28, RBK40 versiones anteriores a 2.3.0.28, RBR40 versiones anteriores a 2.3.0.28, RBS40 versiones anteriores a 2.3.0.28, R6020 versiones anteriores a 1.0.0.34, R6080 versiones anteriores a 1.0.0.34, R6120 versiones anteriores a 1.0.0.44, R6220 versiones anteriores a 1.1.0.80, R6230 versiones anteriores a 1.1.0.80, R6250 versiones anteriores a 1.0.4.34, R6260 versiones anteriores a 1.1.0.40, R6850 versiones anteriores a 1.1.0.40, R6350 versiones anteriores a 1.1.0.40, R6400v2 versiones anteriores a 1.0.2.62, R6700v3 versiones anteriores a 1.0.2.62, R6700v2 versiones anteriores a 1.2.0.36, R6800 versiones anteriores a 1.2.0.36, R6900v2 versiones anteriores a 1.2.0.36, R7000 versiones anteriores a 1.0.9.34, R6900P versiones anteriores a 1.3.1.44, R7000P versiones anteriores a 1.3.1.44, R7100LG versiones anteriores a 1.0.0.48, R7200 versiones anteriores a 1.2.0.48, R7350 versiones anteriores a 1.2.0.48, R7400 versiones anteriores a 1.2.0.48, R7450 versiones anteriores a 1.2.0.36, AC2100 versiones anteriores a 1.2.0.36, AC2400 versiones anteriores a 1.2.0.36, AC2600 versiones anteriores a 1.2.0.36, R7500v2 versiones anteriores a 1.0.3.38, R7800 versiones anteriores a 1.0.2.58, R7900 versiones anteriores a 1.0.3.8, R7960P versiones anteriores a 1.4.1.44, R8000 versiones anteriores a 1.0.4.28, R7900P versiones anteriores a 1.4.1.30, R8000P versiones anteriores a 1.4.1.30, R8900 versiones anteriores a 1.0.4.2, R9000 versiones anteriores a 1.0.4.2, RAX120 versiones anteriores a 1.0.0.74, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, WNR3500Lv2 versiones anteriores a 1.2.0.56, XR450 versiones anteriores a 2.3.2.32, and XR500 versiones anteriores a 2.3.2.32" } ], "id": "CVE-2021-38516", "lastModified": "2024-11-21T06:17:18.220", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10.0, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-11T00:15:25.580", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063780/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2020-0273" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063780/Security-Advisory-for-Missing-Function-Level-Access-Control-on-Some-Routers-Gateways-and-WiFi-Systems-PSV-2020-0273" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | r7850_firmware | * | |
netgear | r7850 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R7850 versiones anteriores a 1.0.5.74, a R7900P versiones anteriores a 1.4.2.84, a R7960P versiones anteriores a 1.4.2.84, a R8000 versiones anteriores a 1.0.4.74, a R8000P versiones anteriores a 1.4.2.84, a RAX200 versiones anteriores a 1. 0.4.120, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45545", "lastModified": "2024-11-21T06:32:28.667", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.133", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064522/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0557" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064522/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0557" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA48F47-FC18-4953-BA90-1F4F3695A2BE", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC9EE9DE-DD58-46A9-87FB-D284EBE0ACC1", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0095B9D4-E161-4050-B283-2166CB86CB24", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0702F9B6-2DAC-4308-8737-9F85AD28E847", "versionEndExcluding": "1.0.4.118", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E06EFF-9D71-43DB-A304-9A41998FD68A", "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4195BC65-A849-4C3A-B726-E013CEB57F32", "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3AE70236-D1C6-4B58-8385-1FA5F71916AF", "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA1BB56F-20B5-4A79-AE9D-429A011EAA4C", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29757651-068E-4646-AAD8-2CF8FD08B34C", "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr80:-:*:*:*:*:*:*:*", "matchCriteriaId": "2A086E76-3F23-4C21-AC96-F11372A8A186", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1582E16D-ACEE-4E33-9D52-9DD25C035EA8", "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms80:-:*:*:*:*:*:*:*", "matchCriteriaId": "DE1A0669-790A-4EE7-A0DC-6E1023D6B4F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk83_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6934383-3E7A-46A5-8147-16C595604ADA", "versionEndExcluding": "1.1.2.20", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk83:-:*:*:*:*:*:*:*", "matchCriteriaId": "7C6C7ABC-87BF-4F20-8DAF-D9B9ACA4A273", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MR80 before 1.1.2.20, MS60 before 1.0.6.116, MS80 before 1.1.2.20, MK62 before 1.0.6.116, MK83 before 1.1.2.20, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, EAX20 versiones anteriores a 1.0.0.58, EAX80 versiones anteriores a 1.0.1.68, LAX20 versiones anteriores a 1.1.6.28, MR60 versiones anteriores a 1.0.6.116, MR80 versiones anteriores a 1.1.2.20, MS60 versiones anteriores a 1.0.6.116, MS80 versiones anteriores a 1.1.2.20, MK62 versiones anteriores a 1.0.6.116, MK83 versiones anteriores a 1. 1.2.20, R6400 versiones anteriores a 1.0.1.70, R6400v2 versiones anteriores a 1.0.4.106, R6700v3 versiones anteriores a 1.0.4.106, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1. 0.11.126, R7000P versiones anteriores a 1.3.3.140, R7850 versiones anteriores a 1.0.5.74, R7900 versiones anteriores a 1.0.4.46, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2. 84, R8000 versiones anteriores a 1.0.4.74, R8000P versiones anteriores a 1.4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4. 120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1. 0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17. 12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80, XR1000 versiones anteriores a 1.0.0.58 y XR300 versiones anteriores a 1.0.3.68" } ], "id": "CVE-2021-45620", "lastModified": "2024-11-21T06:32:41.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.703", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064510/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0509" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064510/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0509" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo CSRF. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14432", "lastModified": "2024-11-21T05:03:15.507", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.327", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061937/Security-Advisory-for-Cross-Site-Request-Forgery-on-Some-WiFi-Systems-PSV-2020-0049" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-352" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v_firmware | 2.6.2.4 | |
netgear | rbs40v | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDC785-6FEC-4D94-86D1-8E55FB0CA6C1", "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true }, { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:2.6.2.4:*:*:*:*:*:*:*", "matchCriteriaId": "62E0BEB9-020B-49C0-AF0D-A874CE9AD8B3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 3.2.18.2, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2. 17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBS40V versiones anteriores a 2.6.2.4 y RBW30 versiones anteriores a 2.6.2.2" } ], "id": "CVE-2021-45628", "lastModified": "2024-11-21T06:32:43.157", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.097", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45503", "lastModified": "2024-11-21T06:32:21.797", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.033", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064127/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0474" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064127/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0474" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29076", "lastModified": "2024-11-21T06:00:39.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.920", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063015/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0485" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98", "versionEndExcluding": "1.0.2.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, R7000 versiones anteriores a 1.0.11 116, R7900 versiones anteriores a 1.0.4.38, R8000 versiones anteriores a 1.0.4.68, RAX200 versiones anteriores a 1.0.3.106, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.6.110, R7000P versiones anteriores a 1.3.2. 126, RAX20 versiones anteriores a 1.0.2.82, RAX45 versiones anteriores a 1.0.2.72, RAX80 versiones anteriores a 1.0.3.106, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.6.110, R6900P versiones anteriores a 1.3.2.126, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1. 0.2.72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45670", "lastModified": "2024-11-21T06:32:50.360", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.7, "impactScore": 5.3, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:21.007", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-26910", "lastModified": "2024-11-21T05:20:28.393", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:16.857", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062343/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0031" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062343/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0031" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | eax80_firmware | * | |
netgear | eax80 | - | |
netgear | ex3700_firmware | * | |
netgear | ex3700 | - | |
netgear | ex3800_firmware | * | |
netgear | ex3800 | - | |
netgear | ex6120_firmware | * | |
netgear | ex6120 | - | |
netgear | ex6130_firmware | * | |
netgear | ex6130 | - | |
netgear | ex7500_firmware | * | |
netgear | ex7500 | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | cbr40_firmware | * | |
netgear | cbr40 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX80 versiones anteriores a 1.0.1.64, EX3700 versiones anteriores a 1.0.0.90, EX3800 versiones anteriores a 1.0.0.90, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, RBW30 versiones anteriores a 2. 6.1.4, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4" } ], "id": "CVE-2021-45666", "lastModified": "2024-11-21T06:32:49.713", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.7, "impactScore": 5.3, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:20.827", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29F1DCF3-43BE-40C3-9BEF-00D4618611B4", "versionEndExcluding": "1.0.0.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2826A7E-990D-455A-8B16-CBCCC4633B97", "versionEndExcluding": "1.0.1.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82B05B23-A689-4A0A-8569-9FA7972EA663", "versionEndExcluding": "1.0.11.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6364559-B141-43AE-B40A-506B79BCC3AA", "versionEndExcluding": "1.0.4.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6C5E300-92E2-447A-822F-B95D1C59530E", "versionEndExcluding": "1.0.4.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49D5D1E8-637A-4970-8753-6A3FCA8FAC64", "versionEndExcluding": "1.0.2.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61807742-C521-47BA-9285-667C58DDD86B", "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "989EB842-6F21-4814-9E03-AF52BBBEA7B9", "versionEndExcluding": "1.0.2.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS reflejado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.32, EAX80 versiones anteriores a 1.0.1.62, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7000 versiones anteriores a 1.0.1.104, EX7500 versiones anteriores a 1.0.0.72, R7000 versiones anteriores a 1.0.11. 110, R7900 versiones anteriores a 1.0.4.30, R7960P versiones anteriores a 1.4.1.66, R8000 versiones anteriores a 1.0.4.62, RAX200 versiones anteriores a 1.0.2.102, XR300 versiones anteriores a 1.0.3.50, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.5.102, R7000P versiones anteriores a 1.3.2.126, R8000P versiones anteriores a 1. 4.1.66, RAX20 versiones anteriores a 1.0.1.64, RAX50 versiones anteriores a 1.0.2.28, RAX80 versiones anteriores a 1.0.3.102, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.5.102, R6900P versiones anteriores a 1.3.2.126, R7900P versiones anteriores a 1.4.1.66, RAX15 versiones anteriores a 1.0.1. 64, RAX45 versiones anteriores a 1.0.2.28, RAX75 versiones anteriores a 1.0.3.102, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45639", "lastModified": "2024-11-21T06:32:44.890", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.1, "impactScore": 2.7, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.597", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45572", "lastModified": "2024-11-21T06:32:33.380", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.417", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064094/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0080" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064094/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0080" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "13C16392-F041-4A90-90C0-C291C0CD545E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C76041B8-E676-4E29-BE18-E1B9C4735D5C", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects RBW30 before 2.6.1.4, RBS40V before 2.6.1.4, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBK754 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK854 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de informaci\u00f3n confidencial.\u0026#xa0;Esto afecta a RBW30 versiones anteriores a 2.6.1.4, RBS40V versiones anteriores a 2.6.1.4, RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBK754 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores al 3.2.15.25, RBK853 versiones anteriores al 3.2.15.25, RBK854 versiones anteriores al 3.2.15.25, RBR850 versiones anteriores al 3.2.15.25 y RBS850 versiones anteriores al 3.2.15.25" } ], "id": "CVE-2021-29082", "lastModified": "2024-11-21T06:00:40.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.3, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.390", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063005/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0037" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | mk62_firmware | * | |
netgear | mk62 | - | |
netgear | mk63_firmware | * | |
netgear | mk63 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C17F8372-6149-455C-B48F-4BE45DC92EC7", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk63_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "08087535-0C20-4FB8-9F73-CD4817343459", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk63:-:*:*:*:*:*:*:*", "matchCriteriaId": "3DFA7D26-4286-40B2-94CB-0D2A6E6FCF1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9584E85F-AD4C-46A2-A96A-0FE52E0B4FE9", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63495F09-8D4B-4BAC-96C0-3A15D9019C14", "versionEndExcluding": "1.0.4.92", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects MK62 before 1.0.4.92, MK63 before 1.0.4.92, MR60 before 1.0.4.92, MS60 before 1.0.4.92, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBS750 before 3.2.15.25, RBR750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a MK62 versiones anteriores a 1.0.4.92, MK63 versiones anteriores a 1.0.4.92, MR60 versiones anteriores a 1.0.4.92, MS60 versiones anteriores a 1.0.4.92, RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14429", "lastModified": "2024-11-21T05:03:14.980", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.077", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061938/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0050" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26926", "lastModified": "2024-11-21T05:20:30.790", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:18.247", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3. 2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29078", "lastModified": "2024-11-21T06:00:40.030", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.077", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063009/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0511" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | eax20_firmware | * | |
netgear | eax20 | - | |
netgear | eax80_firmware | * | |
netgear | eax80 | - | |
netgear | ex3700_firmware | * | |
netgear | ex3700 | - | |
netgear | ex3800_firmware | * | |
netgear | ex3800 | - | |
netgear | ex6120_firmware | * | |
netgear | ex6120 | - | |
netgear | ex6130_firmware | * | |
netgear | ex6130 | - | |
netgear | ex7500_firmware | * | |
netgear | ex7500 | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D", "versionEndExcluding": "1.0.0.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a EAX20 versiones anteriores a 1.0.0.36, EAX80 versiones anteriores a 1.0.1.62, EX3700 versiones anteriores a 1.0.0.90, EX3800 versiones anteriores a 1.0.0.90, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, RBW30 versiones anteriores a 2.6.1.4, RBW40V versiones anteriores a 2.6.1.4. 6.1.4, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4" } ], "id": "CVE-2021-45665", "lastModified": "2024-11-21T06:32:49.553", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "NONE", "baseScore": 3.5, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.8, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 0.7, "impactScore": 5.3, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 4.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 2.7, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:20.780", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45562", "lastModified": "2024-11-21T06:32:31.677", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.940", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | ex7500_firmware | * | |
netgear | ex7500 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbke963_firmware | * | |
netgear | rbke963 | - | |
netgear | rbre960_firmware | * | |
netgear | rbre960 | - | |
netgear | rbse960_firmware | * | |
netgear | rbse960 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A", "versionEndExcluding": "2.6.1.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbke963_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D52E6698-739A-4CD2-9FF4-37BB26641A84", "versionEndExcluding": "6.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbke963:-:*:*:*:*:*:*:*", "matchCriteriaId": "2A373427-186D-4741-9751-211FA26DA3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbre960_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "49A5CF62-650B-4579-8527-F1D876D7D8B7", "versionEndExcluding": "6.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbre960:-:*:*:*:*:*:*:*", "matchCriteriaId": "314FF95E-5A0C-4A6B-B8D6-28546F2C1A12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbse960_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A33F65C-6916-479C-B5F7-FCA5C158A213", "versionEndExcluding": "6.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbse960:-:*:*:*:*:*:*:*", "matchCriteriaId": "419AF785-61C6-4911-A170-6A06D7991948", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a EX7500 versiones anteriores a 1.0.0.72, a RBS40V versiones anteriores a 2.6.1.4, a RBW30 versiones anteriores a 2.6.1.4, a RBRE960 versiones anteriores a 6.0.3.68, a RBSE960 versiones anteriores a 6.0.3.68, a RBR750 versiones anteriores a 3.2.17.12, a RBR850 versiones anteriores a 3.2.10.11. 2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3.2.17.12 y RBK852 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45515", "lastModified": "2024-11-21T06:32:23.680", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 3.3, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.627", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBK852 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17. 12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29075", "lastModified": "2024-11-21T06:00:39.567", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.857", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063010/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Systems-PSV-2020-0466" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7001C735-233D-49D6-8289-38E5CCE6E8BA", "versionEndExcluding": "2.5.0.14", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "831DEEB8-5BA1-48E6-882E-F31466516452", "versionEndExcluding": "1.0.1.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*", "matchCriteriaId": "88DD070C-7CBD-48A5-8D77-7C3D1C502D65", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EF79426-64C8-4FAB-A199-AB7CB82FCD53", "versionEndExcluding": "1.0.1.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*", "matchCriteriaId": "49846803-C6FB-4DD3-ADA7-78B9923536F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D22C6800-451D-472D-9E14-CBFBFD3BC6EC", "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7694D0C-2CC6-4A6E-A251-5CBFC67D2AA9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A60E332-CA18-4617-B7C1-4BE82470DE34", "versionEndExcluding": "1.0.2.158", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF2A822-3756-4966-BFC2-3C69850023E2", "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:v2:*:*:*:*:*:*:*", "matchCriteriaId": "946947C2-E4B2-4984-9233-4D4890E1BE07", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BD99BE2-29BF-4BB5-A8C0-C5E8ACF37D87", "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*", "matchCriteriaId": "C63267D8-4632-4D14-B39C-BEEC62AD8F87", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6420_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B53ACF6-D0A6-4C2B-AAE4-1FFABA43CE4C", "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6420:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B2C00E1-4A23-4304-B92F-B7D9F4818D90", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "374F6EAA-A607-4A8F-BA86-EA770BA99189", "versionEndExcluding": "1.0.2.158", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "374F6EAA-A607-4A8F-BA86-EA770BA99189", "versionEndExcluding": "1.0.2.158", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:v2:*:*:*:*:*:*:*", "matchCriteriaId": "A44B9FAB-7EC4-4B2B-B3E5-A372645AE661", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16389368-58DD-4EC1-A7F2-398AFF6A1E41", "versionEndExcluding": "1.0.0.132", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1D4DF51-84EA-4296-9E06-CE5E1F4A53D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8DC1B77-994C-473C-AC97-7CC06341C607", "versionEndExcluding": "1.0.0.216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7700:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D140E3B-9AE5-473A-82DE-9B9DBAE4C34A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4F00B47-FFC8-4D45-B49E-8347504A9A4C", "versionEndExcluding": "1.0.1.232", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "973084FA-72C8-4ADB-86B8-57C42FDB6569", "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EC30751-F447-45A7-8C57-B73042869EA5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk12:-:*:*:*:*:*:*:*", "matchCriteriaId": "D5465A78-4826-4F72-9CBE-528CBF286A79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8246B8D3-8455-43B1-B0FA-F677B8FF84F5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr10:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DADAA79-9A5C-4B6F-A58D-704ACD1C3334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28DA498C-B466-422E-BAD2-A1F9A15B157F", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs10:-:*:*:*:*:*:*:*", "matchCriteriaId": "32BAB5C0-F645-4A90-833F-6345335FA1AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E72FDDB4-0802-467B-A255-06C8CE1A0B92", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C80BEFF8-7094-4F21-B9E7-EE5C8B9DF3B3", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04F03BE5-1440-4BC4-B902-97E702ED0ADF", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09631703-25CD-40CB-80A8-AADD43939507", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E21623E-9977-486F-93B1-858FC407E9D1", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A32769CF-7D0A-4A3F-AF20-6202CA0C6870", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E3BFCB-BFF8-4722-BE48-5FA93CACD3AD", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "39D6318D-F5A2-4469-B508-075F2825F0FA", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F44708A-C946-4E0F-9D6C-A91AFB4C9EF3", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9E75105-CB35-4983-8CC0-98699AAA63BE", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*", "matchCriteriaId": "27F93A76-6EFF-4DA6-9129-4792E2C125D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4476F0C6-0A7D-4735-940C-F5C75316EEE9", "versionEndExcluding": "2.3.2.114", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.14, EX6100v2 before 1.0.1.98, EX6150v2 before 1.0.1.98, EX6250 before 1.0.0.132, EX6400 before 1.0.2.158, EX6400v2 before 1.0.0.132, EX6410 before 1.0.0.132, EX6420 before 1.0.0.132, EX7300 before 1.0.2.158, EX7300v2 before 1.0.0.132, EX7320 before 1.0.0.132, EX7700 before 1.0.0.216, EX8000 before 1.0.1.232, R7800 before 1.0.2.78, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.6.2.4, RBS50Y before 2.6.1.40, RBW30 before 2.6.2.2, and XR500 before 2.3.2.114." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.14, EX6100v2 versiones anteriores a 1.0.1.98, EX6150v2 versiones anteriores a 1.0.1.98, EX6250 versiones anteriores a 1.0.0.132, EX6400 versiones anteriores a 1.0.2.158, EX6400v2 versiones anteriores a 1.0.0.132, EX6410 versiones anteriores a 1.0.0.132, EX6420 versiones anteriores a 1.0.0.132, EX7300 versiones anteriores a 1. 0.2.158, EX7300v2 versiones anteriores a 1.0.0.132, EX7320 versiones anteriores a 1.0.0.132, EX7700 versiones anteriores a 1.0.0.216, EX8000 versiones anteriores a 1.0.1.232, R7800 versiones anteriores a 1.0.2.78, RBK12 versiones anteriores a 2.6.1.44, RBR10 versiones anteriores a 2.6.1.44, RBS10 versiones anteriores a 2.6.1.44, RBK20 versiones anteriores a 2. 6.1.38, RBR20 versiones anteriores a 2.6.1.36, RBS20 versiones anteriores a 2.6.1.38, RBK40 versiones anteriores a 2.6.1.38, RBR40 versiones anteriores a 2.6.1.36, RBS40 versiones anteriores a 2.6.1.38, RBK50 versiones anteriores a 2.6.1.40, RBR50 versiones anteriores a 2.6.1.40, RBS50 versiones anteriores a 2.6.1.40, RBK752 versiones anteriores a 3.2.16. 6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBS40V versiones anteriores a 2.6.2.4, RBS50Y versiones anteriores a 2.6.1.40, RBW30 versiones anteriores a 2.6.2.2 y XR500 versiones anteriores a 2.3.2.114" } ], "id": "CVE-2021-38527", "lastModified": "2024-11-21T06:17:20.593", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-11T00:16:18.947", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063778/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Extenders-Routers-and-WiFi-Systems-PSV-2020-0025" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063778/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Extenders-Routers-and-WiFi-Systems-PSV-2020-0025" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADF65DC4-51D5-4C38-B28D-7EA93B1734A3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "888A8E0F-93DD-436D-B00C-F469C3BD6E5B", "versionEndExcluding": "1.0.0.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FB6EE3C6-6BA3-4D37-B43B-B98E6EDFDD41", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E1D0A84-92A5-4E07-B2BB-ED4431E64457", "versionEndExcluding": "1.0.3.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A59578F-1A3F-428B-A995-572C8E93C15C", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5E273CF7-2DB6-4641-8753-810949D631B0", "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "049629DD-9E4F-4F47-98B0-C9FD457B74A0", "versionEndExcluding": "1.0.4.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E00ABB7-A3E9-4E41-82CB-3AADC276C3AC", "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA1BB56F-20B5-4A79-AE9D-429A011EAA4C", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "19E991D4-ADE8-4EFC-A405-DBAF07FFEB21", "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "611768C9-4B1D-42CC-97CF-78D05EA332AC", "versionEndExcluding": "1.0.4.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1AC36017-5BCF-4CF6-91D0-278279943847", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50", "versionEndExcluding": "1.0.5.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6364559-B141-43AE-B40A-506B79BCC3AA", "versionEndExcluding": "1.0.4.30", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0ECEE38A-B0BB-43F8-AB4D-26572B789BFB", "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D444B09-82DA-4225-A292-B28232408A7B", "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "609B0EC8-FCD3-4522-A06A-7CB521586A22", "versionEndExcluding": "1.0.2.88", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4AF96D62-1D28-4FE5-AFC3-FB93A1BB4D45", "versionEndExcluding": "1.0.3.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DF6302-36B7-49CF-8F2C-4C2247112EB9", "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F8E565CF-8408-4502-97BD-01CEF15D0744", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DAB3F350-9094-4B64-8ED9-517069EB56F4", "versionEndExcluding": "1.4.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "60634A15-B02A-4C33-A1A4-F6340CFD6B8B", "versionEndExcluding": "1.0.2.144", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta a D6220 versiones anteriores a 1.0.0.68, al D6400 versiones anteriores a 1.0.0.102, a D7000v2 versiones anteriores a 1.0.0.66, al D8500 versiones anteriores a 1.0.3.58, al DC112A versiones anteriores a 1.0.0.54, a EX7000 versiones anteriores a 1.0.1.94, a EX7500 versiones anteriores a 1.0.0.72, a R6250 versiones anteriores a 1.0.4.48, a R6300v2 versiones anteriores a 1. 0.4.52, R6400 versiones anteriores a 1.0.1.70, R6400v2 versiones anteriores a 1.0.4.102, R6700v3 versiones anteriores a 1.0.4.102, R7000 versiones anteriores a 1.0.11.116, R7100LG versiones anteriores a 1.0.0.64, R7850 versiones anteriores a 1.0.5.68, R7900 versiones anteriores a 1.0.4.30, R7960P versiones anteriores a 1.4.1.68, R8000 versiones anteriores a 1.0.4. 52, RAX200 versiones anteriores a 1.0.2.88, RBS40V versiones anteriores a 2.6.2.4, RS400 versiones anteriores a 1.5.1.80, XR300 versiones anteriores a 1.0.3.56, R7000P versiones anteriores a 1.3.2.124, R8000P versiones anteriores a 1.4.1.68, R8500 versiones anteriores a 1.0.2.144, RAX80 versiones anteriores a 1.0.3.102, R6900P versiones anteriores a 1.3.2. 124, R7900P versiones anteriores a 1.4.1.68, R8300 versiones anteriores a 1.0.2.144, RAX75 versiones anteriores a 1.0.3.102, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3.2.17.12 y RBK852 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45527", "lastModified": "2024-11-21T06:32:25.610", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.207", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-120" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45579", "lastModified": "2024-11-21T06:32:34.577", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.747", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-26902", "lastModified": "2024-11-21T05:20:27.097", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:15.463", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062352/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0041" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062352/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0041" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | r7850_firmware | * | |
netgear | r7850 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R7850 versiones anteriores a 1.0.5.74, a R7900P versiones anteriores a 1.4.2.84, a R7960P versiones anteriores a 1.4.2.84, a R8000 versiones anteriores a 1.0.4.74, a R8000P versiones anteriores a 1.4.2.84, a RAX200 versiones anteriores a 1.0.4.120, a RAX75 versiones anteriores a 1.0.4. 120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45547", "lastModified": "2024-11-21T06:32:29.000", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.227", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064525/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0567" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064525/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0567" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "003185A9-52A8-42BB-A898-CE9F020AC301", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28A22215-3A55-44B2-906D-10518A24F83C", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "894527F8-4315-4CF0-A3D5-EACC612E0318", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1C6098D-779F-4807-988F-90103E312896", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, RBK842 before 3.2.10.11, RBR840 before 3.2.10.11, and RBS840 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBK853 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11, RBS850 versiones anteriores a 3.2.10.11, RBK842 versiones anteriores a 3.2.10.11, RBR840 versiones anteriores a 3.2.10.11 y RBS840 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-14426", "lastModified": "2024-11-21T05:03:14.453", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:11.813", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061931/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-Wifi-Systems-PSV-2020-0033" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.1 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr854_firmware | * | |
netgear | rbr854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | r7000_firmware | * | |
netgear | r7000 | - | |
netgear | r6900p_firmware | * | |
netgear | r6900p | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | r7000p_firmware | * | |
netgear | r7000p | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "003185A9-52A8-42BB-A898-CE9F020AC301", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "236C92E0-52FF-4639-819E-3EF0615639A9", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr854:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEB30F51-49A4-448E-971F-BC70B389554C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3", "versionEndExcluding": "1.0.11.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F5A371E-41CA-4C5A-8DDC-3BD197F49096", "versionEndExcluding": "1.0.4.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45", "versionEndExcluding": "1.4.1.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423", "versionEndExcluding": "1.3.2.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un restablecimiento de contrase\u00f1a por parte de un atacante no autenticado. Esto afecta al RBK852 versiones anteriores a 3.2.10.11, al RBK853 versiones anteriores a 3.2.10.11, al RBR854 versiones anteriores a 3.2.10.11, al RBR850 versiones anteriores a 3.2.10.11, al RBS850 versiones anteriores a 3.2.10.11, al CBR40 versiones anteriores a 2.5.0.10, al R7000 versiones anteriores a 1.0.11.116, al R6900P versiones anteriores a 1. 3.2.126, R7900 versiones anteriores a 1.0.4.38, R7960P versiones anteriores a 1.4.1.66, R8000 versiones anteriores a 1.0.4.66, R7900P versiones anteriores a 1.4.1.66, R8000P versiones anteriores a 1.4.1.66, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102 y R7000P versiones anteriores a 1.3.2.126" } ], "id": "CVE-2021-29080", "lastModified": "2024-11-21T06:00:40.337", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.217", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-640" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45627", "lastModified": "2024-11-21T06:32:43.000", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.050", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064124/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0471" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064124/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0471" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.4 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2100_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C1280B1-A2DF-4CAB-AB19-6B463206AA3D", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2100:-:*:*:*:*:*:*:*", "matchCriteriaId": "A80B06A1-81B5-4C33-89F6-EC3F6E3068B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "76C658A4-BF82-40CE-A5E1-C9F3DA1A9B0B", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2400:-:*:*:*:*:*:*:*", "matchCriteriaId": "6B25A18F-DD96-45FE-B098-71E60CB0FFFE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ac2600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A3A6655-B468-46FB-84D7-2294D4243C91", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ac2600:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BFCD9A8-1846-48C4-9F14-3866E983FB74", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C3B3284-B11F-4752-9C6A-0B5BECA3DB2B", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "E526746E-1ED6-492E-B28C-A1CA8235D9FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "762CAE87-3C98-4DB8-9B3D-5CCC3D555004", "versionEndExcluding": "1.0.0.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F2A04BB9-E816-49B5-B539-4B36A5CFFA22", "versionEndExcluding": "1.0.0.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F4BC21D-8354-4C71-BE68-9D1A14A9471F", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B3DCFE88-1262-43BF-88BB-B26658EDEDF1", "versionEndExcluding": "1.0.0.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93A32171-41B3-43DF-9027-51382D83158A", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA2D4987-3726-4A72-8D32-592F59FAC46D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F3F88DD-CE38-45A8-990A-4770A480D1BF", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D989E9B-5626-4238-877A-FFB0FC1C6352", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*", "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dgn2200v4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE1AC249-D64C-4E61-A22A-1498712D2758", "versionEndExcluding": "1.0.0.114", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dgn2200v4:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BE59214-C8A1-4337-A54C-E4E8C149B241", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFD91F26-5253-4A05-AB69-94CB2C416F83", "versionEndExcluding": "1.0.0.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*", "matchCriteriaId": "1B048F71-70F1-4D9F-84E2-9F7340F6ADAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F81FC1BC-5186-4642-AD43-459C707B18CB", "versionEndExcluding": "1.0.1.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5341B659-DE7D-43F1-954D-82049CBE18AD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3110_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "16871358-4EF4-4517-BA05-6ED135691566", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3110:-:*:*:*:*:*:*:*", "matchCriteriaId": "3C254694-4C37-4C5E-BF1C-06EC09BDCA1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "953A4436-6F98-494C-B184-354E577F8E59", "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF7B1DD1-E197-461C-9537-C6D1DF2F6D7D", "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3920_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33BDAF99-3E64-427E-ACAF-AEFB75401C72", "versionEndExcluding": "1.0.0.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3920:-:*:*:*:*:*:*:*", "matchCriteriaId": "E576341B-2426-4F4D-8DF4-0A6D462656A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EDB99B74-2E41-4986-96BB-B728ED32405B", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*", "matchCriteriaId": "02E7CA7E-E6CA-4BAB-8F40-4731EA523D91", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6100v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "93543159-8F91-471D-BBE8-2956520DBD71", "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6100v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "4DCFF79A-8ACE-455B-90F3-FFC745E8BAD4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6110_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E7EBD31-5A65-442D-B7BD-B8A20BE37C20", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6110:-:*:*:*:*:*:*:*", "matchCriteriaId": "04329A16-D96D-4E1D-8AC9-EA3882F1DC41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1AA1E29-118C-4299-91FA-2C8584EC6F6C", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B845CEBF-A8A2-474B-9094-43AA53560150", "versionEndExcluding": "1.0.0.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150v1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3141B266-38D7-43DB-B3CD-750D491F0AEA", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150v1:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FD610F2-64B7-4141-A387-69A2A97C20CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6150v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B9B1AB33-CF18-4774-81F9-7ADA5819F8E8", "versionEndExcluding": "1.0.1.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6150v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5828F04B-E373-4E4F-942D-08CCA038418C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6200v1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34961F45-369E-4344-A498-CF822A1503F9", "versionEndExcluding": "1.0.3.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6200v1:-:*:*:*:*:*:*:*", "matchCriteriaId": "AA1A7496-E8F3-48CA-965B-367B3C33F962", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DB1C84E8-B947-4850-9D66-E306557DC316", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7694D0C-2CC6-4A6E-A251-5CBFC67D2AA9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6CFA90DB-6949-4743-9B63-F1E73B28C7D0", "versionEndExcluding": "1.0.2.152", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1289BBB4-1955-46A4-B5FE-BF11153C24F5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "22C5E2C9-E8DA-478A-B3B1-2C0038B5D560", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "5882095F-B22A-4937-BA08-6640140F10AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6410_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DD3A7D2-75CE-4C67-AAE2-75F09653DFA7", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6410:-:*:*:*:*:*:*:*", "matchCriteriaId": "C63267D8-4632-4D14-B39C-BEEC62AD8F87", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6920_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FF964D1-1FCE-467B-8B7F-8189CDF728D4", "versionEndExcluding": "1.0.0.54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6920:-:*:*:*:*:*:*:*", "matchCriteriaId": "65914D7F-39EA-489B-8DE7-8547AFC05F64", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6A096742-1FFA-4C19-B697-EC5154411CF2", "versionEndExcluding": "1.0.1.90", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79610A3C-B1B8-4E1A-B46B-25F58670A759", "versionEndExcluding": "1.0.2.152", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*", "matchCriteriaId": "F285D60D-A5DA-4467-8F79-15EF8135D007", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E3B1295F-3207-4DF4-BA5B-0DE7AB289636", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A88D2A3-3B22-4639-94E9-69CE80F37392", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7320_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EE4BFF4-42DA-4A09-892E-6FBBE72B28A6", "versionEndExcluding": "1.0.0.128", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7320:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1D4DF51-84EA-4296-9E06-CE5E1F4A53D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B59B0C17-2714-48E8-8911-E72488CE32E3", "versionEndExcluding": "1.0.0.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6566C37A-252E-4301-952E-5C6F19F42326", "versionEndExcluding": "1.0.0.210", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7700:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D140E3B-9AE5-473A-82DE-9B9DBAE4C34A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "456DA66C-6B99-4D0D-8F32-952905F9C752", "versionEndExcluding": "1.0.1.224", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D9781C9-799A-4BDA-A027-987627A01633", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D7658849-0743-487B-803F-D49680EDF185", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7", "versionEndExcluding": "1.0.5.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F898DC9-9250-47DF-844C-F7308365135B", "versionEndExcluding": "1.0.0.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "D18D2CCD-424F-41D5-919B-E22B9FA68D36", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6220_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "79B24229-6AC2-489D-B542-4DAA7E630180", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6220:-:*:*:*:*:*:*:*", "matchCriteriaId": "B131B5C8-CB7F-433B-BA32-F05CE0E92A66", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6230_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5B842D-2275-4968-997B-A70A67CBDBEC", "versionEndExcluding": "1.1.0.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6230:-:*:*:*:*:*:*:*", "matchCriteriaId": "C91CADFA-59DB-4B6C-A914-848884F4A4BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2CE369F2-053B-4F67-B295-54EE41C6C4DA", "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*", "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6260_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "23D4F7E6-C042-434E-87B8-55DB18B08B0A", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6260:-:*:*:*:*:*:*:*", "matchCriteriaId": "3C395D49-57F9-4BC1-8619-57127355B86B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD8455EE-AFAD-445D-910B-E8D9F02E8B1B", "versionEndExcluding": "1.0.4.42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6330_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6524B85E-23AC-4983-8331-96E12899B773", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6330:-:*:*:*:*:*:*:*", "matchCriteriaId": "D621D26D-B144-424A-A9CB-19488399ACC1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F105F6F-ECD3-411D-924E-94BCF036C1EA", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6350:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B302909-29CF-4E53-9CCB-8664D3FCB03A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C48E07DA-A6D2-4035-BC2B-DC257148A259", "versionEndExcluding": "1.0.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v1:-:*:*:*:*:*:*:*", "matchCriteriaId": "39608E61-7E2C-49AA-9719-A40095B1C8A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6E32C097-6EDF-4C81-A375-028DB67B6231", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "715A8158-B6A6-43FF-A0C0-0871EAB07667", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v1:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4187FD4-8045-4C00-A8F2-D37B5549E716", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9C5AB644-B80D-48A3-B794-C483FEFAFDED", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9793286-86D2-43BF-B9B8-823C05BCAE4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCCFD041-9413-4E37-8C4D-F50D1B10582B", "versionEndExcluding": "1.0.4.98", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8956A99-1071-42A7-8984-D7134E755CBF", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8956A99-1071-42A7-8984-D7134E755CBF", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6800:-:*:*:*:*:*:*:*", "matchCriteriaId": "09404083-B00B-4C1F-8085-BC242E625CA3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3408536D-FC77-48C5-AD15-C5A170D7417C", "versionEndExcluding": "1.1.0.76", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6850:-:*:*:*:*:*:*:*", "matchCriteriaId": "598B48C5-4706-4431-8C5A-DA496DD1052F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1D59AC0-2859-46C0-B050-3BB8E3E9CB06", "versionEndExcluding": "1.0.2.16", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0794BB7C-1BCF-4F08-8EB2-9C3B150C105A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02672757-31FD-4338-AF2C-63FD1D7C1A19", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9FC6398-60A5-4003-A294-C96AE6DBCED5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D208F2CA-DB20-4C82-8FFF-B99EBFE29713", "versionEndExcluding": "1.0.11.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8841DA90-D1B1-40EB-809D-14C014337AAB", "versionEndExcluding": "1.0.0.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02279B20-D951-46CE-B339-452BC585A4F3", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7200:-:*:*:*:*:*:*:*", "matchCriteriaId": "FECB83F9-D417-4FD3-B293-87BC177E3AEB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7350_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B452611A-43C5-401B-95BD-189020B5C65C", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7350:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFD1A65C-F10F-4C52-8B6D-69992E512EB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "237C68C0-C2A9-4F71-9E08-547F2A317CBC", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7400:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F68AC3B-A31F-4AB0-89E9-BFFDE427AD3B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63697E3A-AAA3-42E7-8116-93C6548D3AB7", "versionEndExcluding": "1.2.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7450:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DA5420D-DD64-4A9C-9B5F-784F0ED2B464", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7500v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C745B393-CC8D-4F88-A6EB-2788E1A4BAF9", "versionEndExcluding": "1.0.3.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7500v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BCA6487-57EC-4630-884F-820BBFE25843", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C393DBF4-8281-4611-B591-CDB9DF0AA958", "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4171EB00-3664-43D5-9B62-A3538C358142", "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9800CB2-C14A-406B-B1FF-B1B62862EBDB", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44537647-E0B2-477D-98A5-7EA850BF3321", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA8D0327-0A72-44EC-9CC2-6CAF6A0C08B2", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F030129E-95C6-4C31-92A6-DABCDC1B534B", "versionEndExcluding": "1.0.4.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3B377E02-0228-4A2F-90F3-A82E7E964B37", "versionEndExcluding": "1.4.1.62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6324787-AE71-423A-B853-8B22CA3A5294", "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72C4B203-565A-43BC-9800-274060CE23F2", "versionEndExcluding": "1.0.2.134", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "57314D03-64B1-4973-9D36-5D22A71DBCBB", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F859165-8D89-4CDD-9D48-9C7923D2261F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DCE56F2-5A45-4B31-99EF-1D8455C71E5C", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*", "matchCriteriaId": "D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B697A877-214C-4701-AA9B-FE9C23FDBCEB", "versionEndExcluding": "1.0.1.136", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax120:-:*:*:*:*:*:*:*", "matchCriteriaId": "1742BD56-84E4-40E1-8C04-098B3715161E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29FB835A-73C6-4F5D-A0F0-C37914B706E7", "versionEndExcluding": "1.0.5.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CD0FE36F-5D34-4872-8A2F-DC5B4710E807", "versionEndExcluding": "1.0.3.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35:-:*:*:*:*:*:*:*", "matchCriteriaId": "4201E4D6-4DDF-4EF3-902A-960DFFF7C9A4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "785CFF3A-013C-4068-B98E-9B0FAA02BB33", "versionEndExcluding": "1.0.3.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40:-:*:*:*:*:*:*:*", "matchCriteriaId": "13D54346-4B03-4296-B050-04EB8CFCA732", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A3B894E-E712-477A-9960-30AFAB2C35CF", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71AE85C-74C4-42C1-BF54-89B6EC38C707", "versionEndExcluding": "1.0.2.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk12_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9EC30751-F447-45A7-8C57-B73042869EA5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk12:-:*:*:*:*:*:*:*", "matchCriteriaId": "D5465A78-4826-4F72-9CBE-528CBF286A79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8246B8D3-8455-43B1-B0FA-F677B8FF84F5", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr10:-:*:*:*:*:*:*:*", "matchCriteriaId": "5DADAA79-9A5C-4B6F-A58D-704ACD1C3334", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28DA498C-B466-422E-BAD2-A1F9A15B157F", "versionEndExcluding": "2.6.1.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs10:-:*:*:*:*:*:*:*", "matchCriteriaId": "32BAB5C0-F645-4A90-833F-6345335FA1AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E72FDDB4-0802-467B-A255-06C8CE1A0B92", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk20:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6C9F31C-3E12-4787-9C9B-14883D9D152A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C80BEFF8-7094-4F21-B9E7-EE5C8B9DF3B3", "versionEndExcluding": "2.6.1.36", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE5DBD66-9C2A-4EFF-87AB-03E791D584B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04F03BE5-1440-4BC4-B902-97E702ED0ADF", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs20:-:*:*:*:*:*:*:*", "matchCriteriaId": "14FC7F5B-7E4F-4A68-8427-D1F553EBE8CA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "09631703-25CD-40CB-80A8-AADD43939507", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk40:-:*:*:*:*:*:*:*", "matchCriteriaId": "12DDD83C-6FF1-433F-ACA1-7B4B147F9A8C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01A3914A-ABAC-4227-BCA1-DB0AAD559494", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9E20E59-2B1E-4E43-A494-2C20FD716D4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A32769CF-7D0A-4A3F-AF20-6202CA0C6870", "versionEndExcluding": "2.6.1.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FDCDE39-0355-43B9-BF57-F3718DA2988D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E3BFCB-BFF8-4722-BE48-5FA93CACD3AD", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BA66D07-D017-49D6-8E72-5C48E940DE1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "39D6318D-F5A2-4469-B508-075F2825F0FA", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F44708A-C946-4E0F-9D6C-A91AFB4C9EF3", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F5C6DF5F-FEFB-4A30-87CC-379E726AE181", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "451C5603-927A-4EB9-BF9D-150FE16A48F8", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B22B149-BD16-42A0-BB1D-DEF483F6B5E1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4187AE9D-C676-4C41-8DFF-8FDC65D2475C", "versionEndExcluding": "2.5.1.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCFCED24-A687-4C5E-BE2E-60C2189254CF", "versionEndExcluding": "1.0.0.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "935C7519-678D-4C40-BD35-3F281890C7C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs50y_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9E75105-CB35-4983-8CC0-98699AAA63BE", "versionEndExcluding": "2.6.1.40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs50y:-:*:*:*:*:*:*:*", "matchCriteriaId": "27F93A76-6EFF-4DA6-9129-4792E2C125D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "993FD563-493C-460C-B379-E02A90295434", "versionEndExcluding": "2.5.0.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "921A8CFC-D86E-4674-998E-31F4F956B5DC", "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn2500rpv2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9FCAF1C-DB77-402B-98D2-8C3FE7DBA8FF", "versionEndExcluding": "1.0.1.56", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn2500rpv2:-:*:*:*:*:*:*:*", "matchCriteriaId": "65FACC9E-3E0E-4416-9280-706F4FCE436A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3000rpv3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E605C33E-0339-4248-9010-D1728C47861A", "versionEndExcluding": "1.0.2.86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3000rpv3:-:*:*:*:*:*:*:*", "matchCriteriaId": "958243A2-6829-464F-80EA-7DD5B6F0DD7A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wn3500rpv1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F357E3F-EDEB-4110-80AD-2061BB9CA066", "versionEndExcluding": "1.0.0.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wn3500rpv1:-:*:*:*:*:*:*:*", "matchCriteriaId": "F68F9615-B36A-45BA-8296-390321C050C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wndr3400v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6803A2E5-5BCE-4DE6-A0EB-3463C81FAD0C", "versionEndExcluding": "1.0.1.32", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wndr3400v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "37F227D8-332F-4D24-BAEA-AA5DB3E3EC95", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr1000v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5464DA45-2B33-430F-A16E-B1FE072B1376", "versionEndExcluding": "1.0.2.78", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr1000v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "252E5C7B-EF02-4374-A43E-02FAA9E697D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:wnr2000v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01374C4A-4D12-4E77-AF7C-459C32C3579B", "versionEndExcluding": "1.2.0.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:wnr2000v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "31247E55-E754-46D0-9A46-B0D319C21221", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr450_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "051E8D2A-0EB0-43A7-9AAA-8519B8CC7FE0", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr450:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B9CE4D-D1EC-4F55-8226-D159CF5F3AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0BCFB551-95C6-4EEF-83F0-4246F67E6668", "versionEndExcluding": "2.3.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E203D92-F97B-4F5B-B395-3A5DEDBF1C1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "89AB672D-DD24-483E-B69D-7E46AF199483", "versionEndExcluding": "1.0.1.34", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr700:-:*:*:*:*:*:*:*", "matchCriteriaId": "E12892C8-5E01-49A6-BF47-09D630377093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D6000 before 1.0.0.80, D6220 before 1.0.0.60, D6400 before 1.0.0.94, D7000v2 before 1.0.0.62, D7800 before 1.0.3.48, D8500 before 1.0.3.50, DC112A before 1.0.0.48, DGN2200v4 before 1.0.0.114, DM200 before 1.0.0.66, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX2700 before 1.0.1.58, EX3110 before 1.0.1.68, EX3700 before 1.0.0.84, EX3800 before 1.0.0.84, EX3920 before 1.0.0.84, EX6000 before 1.0.0.44, EX6100v2 before 1.0.1.94, EX6110 before 1.0.1.68, EX6120 before 1.0.0.54, EX6130 before 1.0.0.36, EX6150v1 before 1.0.0.46, EX6150v2 before 1.0.1.94, EX6200v1 before 1.0.3.94, EX6250 before 1.0.0.128, EX6400 before 1.0.2.152, EX6400v2 before 1.0.0.128, EX6410 before 1.0.0.128, EX6920 before 1.0.0.54, EX7000 before 1.0.1.90, EX7300 before 1.0.2.152, EX7300v2 before 1.0.0.128, EX7320 before 1.0.0.128, EX7500 before 1.0.0.68, EX7700 before 1.0.0.210, EX8000 before 1.0.1.224, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6250 before 1.0.4.42, R6260 before 1.1.0.76, R6300v2 before 1.0.4.42, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400v1 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700v1 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900 before 1.0.2.16, R6900P before 1.3.2.124, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7100LG before 1.0.0.56, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7500v2 before 1.0.3.48, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8300 before 1.0.2.134, R8500 before 1.0.2.134, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.5.24, RAX35 before 1.0.3.80, RAX40 before 1.0.3.80, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.38, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBS40V before 2.5.1.6, RBS40V-200 before 1.0.0.46, RBS50Y before 2.6.1.40, RBW30 before 2.5.0.4, RS400 before 1.5.0.48, WN2500RPv2 before 1.0.1.56, WN3000RPv3 before 1.0.2.86, WN3500RPv1 before 1.0.0.28, WNDR3400v3 before 1.0.1.32, WNR1000v3 before 1.0.2.78, WNR2000v2 before 1.2.0.12, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad.\u0026#xa0;Esto afecta a AC2100 versiones \u0026lt; 1.2.0.72, AC2400 versiones \u0026lt; 1.2.0.72, AC2600 versiones \u0026lt; 1.2.0.72, CBK40 versiones \u0026lt; 2.5.0.10, CBR40 versiones \u0026lt; 2.5.0.10, D6000 versiones \u0026lt; 1.0.0.80, D6220 versiones \u0026lt; 1.0.0.60, D6400 versiones \u0026lt; 1.0.0.94, D7000v2 versiones \u0026lt; 1.0.0.62, D7800 versiones \u0026lt; 1.0.3.48, D8500 versiones \u0026lt; 1.0.3.50, DC112A versiones \u0026lt; 1.0.0.48, DGN2200v4 versiones \u0026lt; 1.0.0.114, DM200 versiones \u0026lt; 1.0.0.66, EAX20 versiones \u0026lt; 1.0.0.36, EAX80 versiones \u0026lt; 1.0.1.62, EX2700 versiones \u0026lt; 1.0.1.58, EX3110 versiones \u0026lt; 1.0.1.68, EX3700 versiones \u0026lt; 1.0.0.84, EX3800 versiones \u0026lt; 1.0.0.84, EX3920 versiones \u0026lt; 1.0.0.84, EX6000 versiones \u0026lt; 1.0.0.44, EX6100v2 versiones \u0026lt; 1.0.1.94, EX6110 versiones \u0026lt; 1.0.1.68, EX6120 versiones \u0026lt; 1.0. 0.54, EX6130 versiones \u0026lt; 1.0.0.36, EX6150v1 versiones \u0026lt; 1.0.0.46, EX6150v2 versiones \u0026lt; 1.0.1.94, EX6200v1 versiones \u0026lt; 1.0.3.94, EX6250 versiones \u0026lt; 1.0.0.128, EX6400 versiones \u0026lt; 1.0.2.152, EX6400v2 versiones \u0026lt; 1.0.0.128, EX6410 versiones \u0026lt; 1.0.0.128, EX6920 versiones \u0026lt; 1.0.0.54, EX7000 versiones \u0026lt; 1.0.1.90, EX7300 versiones \u0026lt; 1.0.2.152, EX7300v2 versiones \u0026lt; 1.0.0.128, EX7320 versiones \u0026lt; 1.0.0.128, EX7500 versiones \u0026lt; 1.0.0.68, EX7700 versiones \u0026lt; 1.0.0.210, EX8000 antes e 1.0.1.224, MK62 versiones \u0026lt; 1.0.5.102, MR60 versiones \u0026lt; 1.0.5.102, MS60 versiones \u0026lt; 1.0.5.102, R6120 versiones \u0026lt; 1.0.0.70, R6220 versiones \u0026lt; 1.1.0.100, R6230 versiones \u0026lt; 1.1.0.100, R6250 versiones \u0026lt; 1.0.4.42, R6260 versiones \u0026lt; 1.1 .0.76, R6300v2 versiones \u0026lt; 1.0.4.42, R6330 versiones \u0026lt; 1.1.0.76, R6350 versiones \u0026lt; 1.1.0.76, R6400v1 versiones \u0026lt; 1.0.1.62, R6400v2 versiones \u0026lt; 1.0.4.98, R6700v1 versiones \u0026lt; 1.0.2.16, R6700v2 versiones \u0026lt; 1.2.0.72, R6700v3 versiones \u0026lt; 1.0.4.98, R6800 versiones \u0026lt; 1.2.0.72, R6800 antes 1.2.0.72, R6850 versiones \u0026lt; 1.1.0.76, R6900 versiones \u0026lt; 1.0.2.16, R6900P versiones \u0026lt; 1.3.2.124, R6900v2 versiones \u0026lt; 1.2.0.72, R7000 versiones \u0026lt; 1.0.11.106, R7000P versiones \u0026lt; 1.3.2.124, R7100LG versiones \u0026lt; 1.0.0.56, R7200 versiones \u0026lt; 1.2. 0.72, R7350 versiones \u0026lt; 1.2.0.72, R7400 versiones \u0026lt; 1.2.0.72, R7450 versiones \u0026lt; 1.2.0.72, R7500v2 versiones \u0026lt; 1.0.3.48, R7800 versiones \u0026lt; 1.0.2.74, R7850 versiones \u0026lt; 1.0.5.60, R7900 versiones \u0026lt; 1.0.4.26, R7900P versiones \u0026lt; 1.4.1.62, R7960P versiones \u0026lt; 1.4.1.62, R8000 versiones \u0026lt; 1.0.4.58, R8000P versiones \u0026lt; 1.4.1.62, R8300 versiones \u0026lt; 1.0.2.134, R8500 versiones \u0026lt; 1.0.2.134, R8900 versiones \u0026lt; 1.0.5.24, R9000 versiones \u0026lt; 1.0.5.24, RAX120 versiones \u0026lt; 1.0.1.136, RAX15 versiones \u0026lt; 1.0.1.64, RAX20 versiones \u0026lt; 1.0.1.64, RAX200 versiones \u0026lt; 1.0.5.24, RAX35 versiones \u0026lt; 1.0.3.80, RAX40 versiones \u0026lt; 1.0.3.80, RAX45 versiones \u0026lt; 1.0.2.64, RAX50 versiones \u0026lt; 1.0.2.64, RAX75 versiones \u0026lt; 1.0.3.102, RAX80 versiones \u0026lt; 1.0. 3.102, RB K12 versiones \u0026lt; 2.6.1.44, RBR10 versiones \u0026lt; 2.6.1.44, RBS10 versiones \u0026lt; 2.6.1.44, RBK20 versiones \u0026lt; 2.6.1.38, RBR20 versiones \u0026lt; 2.6.1.36, RBS20 versiones \u0026lt; 2.6.1.38, RBK40 versiones \u0026lt; 2.6.1.38, RBR40 versiones \u0026lt; 2.6.1.38, RBS40 antes 2.6.1.38, RBK50 versiones \u0026lt; 2.6.1.40, RBR50 versiones \u0026lt; 2.6.1.40, RBS50 versiones \u0026lt; 2.6.1.40, RBK752 versiones \u0026lt; 3.2.16.6, RBR750 versiones \u0026lt; 3.2.16.6, RBS750 versiones \u0026lt; 3.2.16.6, RBK842 versiones \u0026lt; 3.2.16.6, RBR840 versiones \u0026lt; 3.2. 16.6, RBS840 versiones \u0026lt; 3.2.16.6, RBK852 versiones \u0026lt; 3.2.16.6, RBR850 versiones \u0026lt; 3.2.16.6, RBS850 versiones \u0026lt; 3.2.16.6, RBS40V versiones \u0026lt; 2.5.1.6, RBS40V-200 versiones \u0026lt; 1.0.0.46, RBS50Y versiones \u0026lt; 2.6.1.40, RBW30 versiones \u0026lt; 2.5. 0.4, RS400 versiones \u0026lt; 1.5.0.48, WN2500RPv2 versiones \u0026lt; 1.0.1.56, WN3000RPv3 versiones \u0026lt; 1.0.2.86, WN3500RPv1 versiones \u0026lt; 1.0.0.28, WNDR3400v3 versiones \u0026lt; 1.0.1.32, WNR1000v3 versiones \u0026lt; 1.0.2.78, WNR2000v2 versiones \u0026lt; 1.2.0.12, XR30" } ], "id": "CVE-2020-35800", "lastModified": "2024-11-21T05:28:08.620", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 9.7, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 9.5, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.5, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 9.4, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.5, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.410", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062733/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0112" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062733/Security-Advisory-for-Security-Misconfiguration-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0112" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45588", "lastModified": "2024-11-21T06:32:36.107", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.163", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064110/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0096" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064110/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0096" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45629", "lastModified": "2024-11-21T06:32:43.320", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.143", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E56DEEC-4A36-4B33-951A-049D2582F7A4", "versionEndExcluding": "2.6.2.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBW30 versiones anteriores a 2.6.2.2, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17. 12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12 y RBS40V versiones anteriores a 2.6.2.8" } ], "id": "CVE-2021-45507", "lastModified": "2024-11-21T06:32:22.423", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.230", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RAX200 versiones anteriores a 1.0.4.120, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45542", "lastModified": "2024-11-21T06:32:28.170", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.987", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064143/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0540" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064143/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0540" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas.\u0026#xa0;Esto afecta a CBR40 versiones anteriores a 2.5.0.10, RBK752 versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11 y RBS850 versiones anteriores a 3.2.10.11" } ], "id": "CVE-2020-26905", "lastModified": "2024-11-21T05:20:27.563", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-10-09T07:15:16.293", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062349/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0047" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062349/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0047" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45596", "lastModified": "2024-11-21T06:32:37.363", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.533", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064140/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0516" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064140/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0516" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | eax20_firmware | * | |
netgear | eax20 | - | |
netgear | mk62_firmware | * | |
netgear | mk62 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "971A9859-C378-4DEC-9432-364930E662B7", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D842A92-6063-4CF5-B73B-2FD9FCE4225A", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5", "versionEndExcluding": "2.5.0.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B", "versionEndExcluding": "1.0.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "525B767F-5A8A-4E6C-8585-BCBB05948B2D", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*", "matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "78982D53-7AF1-4443-BE50-BF8F3FC9BF16", "versionEndExcluding": "3.2.10.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A06599B3-A691-4496-8043-118F1E8AE304", "versionEndExcluding": "3.2.10.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E2FF118-6526-4F4E-B98A-2DEEE1BC3548", "versionEndExcluding": "3.2.10.10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, MK62 before 1.0.6.110, MR60 before 1.0.6.110, MS60 before 1.0.6.110, RBK752 before 3.2.10.10, RBR750 before 3.2.10.10, and RBS750 before 3.2.10.10." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de la autenticaci\u00f3n. Esto afecta a RBK852 versiones anteriores a 3.2.10.11, RBR850 versiones anteriores a 3.2.10.11, a RBS850 versiones anteriores a 3.2.10.11, CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, MK62 versiones anteriores a 1. 0.6.110, MR60 versiones anteriores a 1.0.6.110, MS60 versiones anteriores a 1.0.6.110, RBK752 versiones anteriores a 3.2.10.10, RBR750 versiones anteriores a 3.2.10.10 y RBS750 versiones anteriores a 3.2.10.10" } ], "id": "CVE-2021-38513", "lastModified": "2024-11-21T06:17:17.480", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-08-11T00:15:10.787", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063777/Security-Advisory-for-Authentication-Bypass-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0008" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063777/Security-Advisory-for-Authentication-Bypass-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0008" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45583", "lastModified": "2024-11-21T06:32:35.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.933", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | r8300_firmware | * | |
netgear | r8300 | - | |
netgear | r8500_firmware | * | |
netgear | r8500 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68D7FF2D-210A-4B16-B871-394413F64F3A", "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45ADC486-2457-496D-B887-EAAB9833E160", "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000P versiones anteriores a 1.4.2.84, R8300 versiones anteriores a 1.0.2.154, R8500 versiones anteriores a 1. 0.2.154, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45615", "lastModified": "2024-11-21T06:32:40.773", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.473", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45570", "lastModified": "2024-11-21T06:32:33.060", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.327", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064092/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0078" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064092/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0078" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RAX75 versiones anteriores a 1.0.3.106, RAX80 versiones anteriores a 1.0.3.106, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45536", "lastModified": "2024-11-21T06:32:27.143", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.697", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45575", "lastModified": "2024-11-21T06:32:33.893", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.553", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064097/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0083" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064097/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0083" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29079", "lastModified": "2024-11-21T06:00:40.187", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.157", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063020/Security-Advisory-for-Pre-Authentication-Command-Injection-Some-WiFi-Routers-PSV-2020-0470" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45585", "lastModified": "2024-11-21T06:32:35.617", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.027", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064107/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0093" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064107/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0093" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45561", "lastModified": "2024-11-21T06:32:31.513", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.893", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064165/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0059" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064165/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0059" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45566", "lastModified": "2024-11-21T06:32:32.407", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.130", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064087/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0070" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064087/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0070" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45574", "lastModified": "2024-11-21T06:32:33.713", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.507", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064096/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0082" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064096/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0082" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBS40V versiones anteriores a 2.6.2.4, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3. 2.17.12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29077", "lastModified": "2024-11-21T06:00:39.877", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:14.013", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063016/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0486" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45577", "lastModified": "2024-11-21T06:32:34.223", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.650", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064099/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0085" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064099/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0085" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2DC48DC1-23F3-4924-AC51-A046FDD68169", "versionEndExcluding": "1.0.4.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8E9DCA2-ED8E-446A-ABE7-8CB6C851FE9A", "versionEndExcluding": "1.0.4.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21A17053-15C7-4B22-AC52-549530A908F3", "versionEndExcluding": "1.0.11.100", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137", "versionEndExcluding": "1.3.2.124", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C393DBF4-8281-4611-B591-CDB9DF0AA958", "versionEndExcluding": "1.0.2.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*", "matchCriteriaId": "17CF7445-6950-45FE-9D1A-E23F63316329", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4171EB00-3664-43D5-9B62-A3538C358142", "versionEndExcluding": "1.0.5.60", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D9800CB2-C14A-406B-B1FF-B1B62862EBDB", "versionEndExcluding": "1.0.4.26", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2B5218F1-2A51-4B1E-A57F-534B74A8FEE2", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D444B09-82DA-4225-A292-B28232408A7B", "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8B02CB0A-BBB8-4A64-93B3-7CA1DF7B7299", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D3F1622-F2B7-41F0-87F0-61F4ACB270C8", "versionEndExcluding": "1.4.1.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD", "versionEndExcluding": "1.0.1.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0950BA50-E185-4091-99F7-D8837F9023F0", "versionEndExcluding": "1.0.1.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9AA26738-7B2A-4774-868D-5CA005C4326D", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFD74459-51B3-4F82-9B1B-72C41BAAD607", "versionEndExcluding": "1.0.2.66", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976", "versionEndExcluding": "1.0.3.102", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "921A8CFC-D86E-4674-998E-31F4F956B5DC", "versionEndExcluding": "1.5.0.48", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49", "versionEndExcluding": "1.0.3.50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects R6400v2 before 1.0.4.84, R6700v3 before 1.0.4.84, R6900P before 1.3.2.124, R7000 before 1.0.11.100, R7000P before 1.3.2.124, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7960P before 1.4.1.50, R8000 before 1.0.4.52, R7900P before 1.4.1.50, R8000P before 1.4.1.50, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.1.12, RAX45 before 1.0.2.66, RAX50 before 1.0.2.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RS400 before 1.5.0.48, and XR300 before 1.0.3.50." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado.\u0026#xa0;Esto afecta a R6400v2 versiones anteriores a 1.0.4.84, R6700v3 versiones anteriores a 1.0.4.84, R6900P versiones anteriores a 1.3.2.124, R7000 versiones anteriores a 1.0.11.100, R7000P versiones anteriores a 1.3.2.124, R7800 versiones anteriores a 1.0.2.74, R7850 versiones anteriores a 1.0.5.60, R7900 versiones anteriores a 1.0.4.26, R7960P versiones anteriores a 1.4.1.50, R8000 versiones anteriores a 1.0.4.52, R7900P versiones anteriores a 1.4.1.50, R8000P versiones anteriores a 1.4.1.50, RAX15 versiones anteriores a 1.0.1.64, RAX20 versiones anteriores a 1.0.1.64, RAX200 versiones anteriores a 1.0.1.12, RAX45 versiones anteriores a 1.0.2.66, RAX50 versiones anteriores a 1.0.2.66, RAX75 versiones anteriores a 1.0.3.102, RAX80 versiones anteriores a 1.0.3.102, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2. 15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RS400 versiones anteriores a 1.5.0.48 y XR300 versiones anteriores a 1.0.3.50." } ], "id": "CVE-2020-35798", "lastModified": "2024-11-21T05:28:08.150", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 9.3, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.5, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-12-30T00:15:14.267", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062715/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2019-0218" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000062715/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2019-0218" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45580", "lastModified": "2024-11-21T06:32:34.743", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.793", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064102/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0088" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064102/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0088" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DCDDC785-6FEC-4D94-86D1-8E55FB0CA6C1", "versionEndExcluding": "3.2.18.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCA48F47-FC18-4953-BA90-1F4F3695A2BE", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC9EE9DE-DD58-46A9-87FB-D284EBE0ACC1", "versionEndExcluding": "1.0.1.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*", "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*", "matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D", "versionEndExcluding": "1.0.3.96", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A", "versionEndExcluding": "1.5.1.80", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*", "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38", "versionEndExcluding": "1.0.0.58", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3AE70236-D1C6-4B58-8385-1FA5F71916AF", "versionEndExcluding": "1.0.3.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*", "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A65EE9FC-A015-4D92-8DA3-40C8594D843D", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ED72FFCA-F5A8-480D-8A29-C14FFC490B33", "versionEndExcluding": "1.0.0.94", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8", "versionEndExcluding": "1.0.0.64", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*", "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07", "versionEndExcluding": "1.0.0.44", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*", "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2826A7E-990D-455A-8B16-CBCCC4633B97", "versionEndExcluding": "1.0.1.104", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EB8CD19-4963-42A8-B9E6-63ED5EC35119", "versionEndExcluding": "1.0.0.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*", "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0", "versionEndExcluding": "1.1.6.28", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*", "matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38", "versionEndExcluding": "1.0.6.116", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E00ABB7-A3E9-4E41-82CB-3AADC276C3AC", "versionEndExcluding": "1.0.4.52", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA1BB56F-20B5-4A79-AE9D-429A011EAA4C", "versionEndExcluding": "1.0.1.70", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A95F7AFD-13E8-49B7-BA80-D8BC61C254FE", "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A33291E-18F7-452C-A5EF-7B3C2D087704", "versionEndExcluding": "1.0.4.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0E06EFF-9D71-43DB-A304-9A41998FD68A", "versionEndExcluding": "1.0.11.126", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD", "versionEndExcluding": "1.3.3.140", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F445F83B-1CFC-41E9-9446-72E1FCE5A222", "versionEndExcluding": "1.0.0.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*", "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4195BC65-A849-4C3A-B726-E013CEB57F32", "versionEndExcluding": "1.0.4.46", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "68D7FF2D-210A-4B16-B871-394413F64F3A", "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45ADC486-2457-496D-B887-EAAB9833E160", "versionEndExcluding": "1.0.2.154", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*", "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 3.2.18.2, EAX20 versiones anteriores a 1.0.0.58, EAX80 versiones anteriores a 1.0.1.68, EX3700 versiones anteriores a 1.0.0.94, EX3800 versiones anteriores a 1.0.0. 94, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7000 versiones anteriores a 1.0.1.104, EX7500 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0. 6.116, R6300v2 versiones anteriores a 1.0.4.52, R6400 versiones anteriores a 1.0.1.70, R6400v2 versiones anteriores a 1.0.4.106, R6700v3 versiones anteriores a 1.0.4.106, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11. 126, R7000P versiones anteriores a 1.3.3.140, R7100LG versiones anteriores a 1.0.0.72, R7850 versiones anteriores a 1.0.5.74, R7900 versiones anteriores a 1.0.4.46, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000 versiones anteriores a 1. 0.4.74, R8000P versiones anteriores a 1.4.2.84, R8300 versiones anteriores a 1.0.2.154, R8500 versiones anteriores a 1.0.2.154, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4. 120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1. 0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2. 17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80, XR1000 versiones anteriores a 1.0.0.58 y XR300 versiones anteriores a 1.0.3.68" } ], "id": "CVE-2021-45621", "lastModified": "2024-11-21T06:32:41.920", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:18.757", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | r7900p_firmware | 1.4.2.84 | |
netgear | r7900p | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:1.4.2.84:*:*:*:*:*:*:*", "matchCriteriaId": "EC6AECC6-7572-4307-AC8C-A59D36A1FDC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R8000 before 1.0.4.74, RAX200 before 1.0.4.120, R8000P before 1.4.2.84, R7900P before 1.4.2.84, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBK852 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R8000 versiones anteriores a 1.0.4.74, a RAX200 versiones anteriores a 1.0.4.120, a R8000P versiones anteriores a 1.4.2.84, a R7900P versiones anteriores a 1.4.2.84, a RBR850 versiones anteriores a 3.2.17.12, a RBS850 versiones anteriores a 3.2.17.12 y a RBK852 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45543", "lastModified": "2024-11-21T06:32:28.333", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.037", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064517/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0541" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064517/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0541" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbw30_firmware | * | |
netgear | rbw30 | - | |
netgear | rbs40v_firmware | * | |
netgear | rbs40v | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbk754_firmware | * | |
netgear | rbk754 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7", "versionEndExcluding": "2.6.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*", "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B", "versionEndExcluding": "2.6.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E1723D5F-FFDB-4E4D-80B7-4B28598D5895", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D041B9F-37E4-48A9-9841-85EFFF7FA1D1", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk754_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6E6FDC1-BB17-454A-9B3A-5FB1F705C56B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk754:-:*:*:*:*:*:*:*", "matchCriteriaId": "F8BF464E-63DB-4AC4-9B5D-E3ECDC000305", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects RBW30 before 2.6.2.2, RBS40V before 2.6.2.4, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a RBW30 versiones anteriores a 2.6.2.2, RBS40V versiones anteriores a 2.6.2.4, RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3. 2.17.12, RBK752 versiones anteriores a 3.2.17.12, RBK753 versiones anteriores a 3.2.17.12, RBK753S versiones anteriores a 3.2.17.12, RBK754 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12 y RBS750 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29067", "lastModified": "2024-11-21T06:00:38.160", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.233", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063017/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0492" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.4 (High) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk854_firmware | * | |
netgear | rbk854 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "64DF0B69-B591-47B6-88C1-82544AA3DE9B", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk854_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "106863FF-9BE9-4C18-9A86-C458FF9EBDD6", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk854:-:*:*:*:*:*:*:*", "matchCriteriaId": "01D12702-8B86-419C-8636-1259FD2D5844", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autentificado. Esto afecta a RBK852 versiones anteriores a 3.2.17.12, RBK853 versiones anteriores a 3.2.17.12, RBK854 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-29072", "lastModified": "2024-11-21T06:00:39.080", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:13.640", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45601", "lastModified": "2024-11-21T06:32:38.167", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:17.757", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064147/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0563" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064147/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0563" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr40_firmware | * | |
netgear | cbr40 | - | |
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD", "versionEndExcluding": "2.5.0.24", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, and RBR850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12 y RBR850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45508", "lastModified": "2024-11-21T06:32:22.573", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:13.280", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064133/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0490" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064133/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0490" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14438", "lastModified": "2024-11-21T05:03:16.597", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.953", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45576", "lastModified": "2024-11-21T06:32:34.057", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.597", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45563", "lastModified": "2024-11-21T06:32:31.873", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.993", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064084/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0066" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064084/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0066" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | r7850_firmware | * | |
netgear | r7850 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r7960p_firmware | * | |
netgear | r7960p | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - | |
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06", "versionEndExcluding": "1.0.5.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*", "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3", "versionEndExcluding": "1.0.4.74", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF", "versionEndExcluding": "1.0.4.120", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R7850 versiones anteriores a 1.0.5.74, a R7900P versiones anteriores a 1.4.2.84, a R7960P versiones anteriores a 1.4.2.84, a R8000 versiones anteriores a 1.0.4.74, a R8000P versiones anteriores a 1.4.2.84, a RAX200 versiones anteriores a 1.0.4.120, a RAX75 versiones anteriores a 1.0.4. 120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45546", "lastModified": "2024-11-21T06:32:28.830", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:15.177", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax200_firmware | * | |
netgear | rax200 | - | |
netgear | mr60_firmware | * | |
netgear | mr60 | - | |
netgear | rax45_firmware | * | |
netgear | rax45 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | ms60_firmware | * | |
netgear | ms60 | - | |
netgear | rax50_firmware | * | |
netgear | rax50 | - | |
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | r7900_firmware | * | |
netgear | r7900 | - | |
netgear | r8000_firmware | * | |
netgear | r8000 | - | |
netgear | r7900p_firmware | * | |
netgear | r7900p | - | |
netgear | r8000p_firmware | * | |
netgear | r8000p | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*", "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1", "versionEndExcluding": "1.0.6.110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*", "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6", "versionEndExcluding": "1.0.2.72", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*", "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741", "versionEndExcluding": "1.0.4.38", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*", "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199", "versionEndExcluding": "1.0.4.68", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E", "versionEndExcluding": "1.4.2.84", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*", "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a R7900 versiones anteriores a 1.0.4.38, a R7900P versiones anteriores a 1.4.2.84, a R8000 versiones anteriores a 1.0.4.68, a R8000P versiones anteriores a 1.4.2.84, a RAX200 versiones anteriores a 1.0.3.106, al MR60 versiones anteriores a 1.0.6.110, a RAX45 versiones anteriores a 1.0.2.72, a RAX80 versiones anteriores a 1.0.3.106, al MS60 versiones anteriores a 1. 0.6.110, RAX50 versiones anteriores a 1.0.2.72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45541", "lastModified": "2024-11-21T06:32:27.987", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.937", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una divulgaci\u00f3n de credenciales administrativas. Esto afecta a RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25, RBS750 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25 y RBS850 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14428", "lastModified": "2024-11-21T05:03:14.810", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 3.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "LOW", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L", "version": "3.0" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.000", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061936/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0044" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbk853_firmware | * | |
netgear | rbk853 | - | |
netgear | rbk842_firmware | * | |
netgear | rbk842 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - | |
netgear | rbr840_firmware | * | |
netgear | rbr840 | - | |
netgear | rbs840_firmware | * | |
netgear | rbs840 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbk753_firmware | * | |
netgear | rbk753 | - | |
netgear | rbk753s_firmware | * | |
netgear | rbk753s | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7300226F-8997-4142-8DAC-682F0E313072", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk853_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A553C5A2-EB80-4314-A623-8F489A4E74E2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk853:-:*:*:*:*:*:*:*", "matchCriteriaId": "4479CEAD-3B87-4993-80C8-1AE59242CFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk842_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "754ACE12-E256-4B21-ABD5-CB5F3DA4BDC7", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk842:-:*:*:*:*:*:*:*", "matchCriteriaId": "0E9B19B2-5FF1-4C85-8504-C33C34F072B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86A9DFB9-8429-45DB-84E8-30F37535145E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4FC4E2F-711C-432A-91FE-27CB1EE41A33", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D19A1E4D-30F2-4263-B4BE-273EED14702E", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr840:-:*:*:*:*:*:*:*", "matchCriteriaId": "4489CB05-A1C0-408C-8D8C-56EE98CA20E8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs840_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44ED0285-F862-44B9-B0EE-C2FDC42706A2", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs840:-:*:*:*:*:*:*:*", "matchCriteriaId": "84AEA27B-8BEA-4E83-819A-FDAC1881928F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE271234-71E6-4F3A-8F39-DA86D1275331", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "436BED04-0FD2-499B-9D42-F9E0AAA6CB97", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753:-:*:*:*:*:*:*:*", "matchCriteriaId": "56AE9F2F-50F1-4917-BB21-FAEE6AACB14E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk753s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F35DDDEC-A64B-400E-ABF8-E13F432BD261", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk753s:-:*:*:*:*:*:*:*", "matchCriteriaId": "192647CA-5BFC-4021-A91D-7CB8761FA137", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "905C4D26-8575-429C-B1D2-FC35C773B129", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60A549C-0D76-4A83-BBCD-C1D04075809B", "versionEndExcluding": "3.2.15.25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK852 versiones anteriores a 3.2.15.25, RBK853 versiones anteriores a 3.2.15.25, RBK842 versiones anteriores a 3.2.15.25, RBR850 versiones anteriores a 3.2.15.25, RBS850 versiones anteriores a 3.2.15.25, RBR840 versiones anteriores a 3.2.15.25, RBS840 versiones anteriores a 3.2.15.25, RBK752 versiones anteriores a 3.2.15.25, RBK753 versiones anteriores a 3.2.15.25, RBK753S versiones anteriores a 3.2.15.25, RBR750 versiones anteriores a 3.2.15.25 y RBS750 versiones anteriores a 3.2.15.25" } ], "id": "CVE-2020-14433", "lastModified": "2024-11-21T05:03:15.677", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.0" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-06-18T17:15:12.453", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000061932/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0035" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45578", "lastModified": "2024-11-21T06:32:34.410", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.697", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45502", "lastModified": "2024-11-21T06:32:21.600", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:12.983", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | cbr750_firmware | * | |
netgear | cbr750 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C", "versionEndExcluding": "4.6.3.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3", "versionEndExcluding": "3.2.17.12", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3.2.17.12 y RBK852 versiones anteriores a 3.2.17.12" } ], "id": "CVE-2021-45633", "lastModified": "2024-11-21T06:32:43.943", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:19.323", "references": [ { "source": "cve@mitre.org", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rax75_firmware | * | |
netgear | rax75 | - | |
netgear | rax80_firmware | * | |
netgear | rax80 | - | |
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182", "versionEndExcluding": "1.0.3.106", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*", "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RAX75 versiones anteriores a 1.0.3.106, RAX80 versiones anteriores a 1.0.3.106, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45538", "lastModified": "2024-11-21T06:32:27.467", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:14.793", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064088/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0074" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064088/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0074" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
6.8 (Medium) - CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbk752_firmware | * | |
netgear | rbk752 | - | |
netgear | rbr750_firmware | * | |
netgear | rbr750 | - | |
netgear | rbs750_firmware | * | |
netgear | rbs750 | - | |
netgear | rbk852_firmware | * | |
netgear | rbk852 | - | |
netgear | rbr850_firmware | * | |
netgear | rbr850 | - | |
netgear | rbs850_firmware | * | |
netgear | rbs850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*", "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*", "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*", "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*", "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F", "versionEndExcluding": "3.2.16.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*", "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6." }, { "lang": "es", "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado. Esto afecta a RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6 y RBS850 versiones anteriores a 3.2.16.6" } ], "id": "CVE-2021-45568", "lastModified": "2024-11-21T06:32:32.723", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "SINGLE", "availabilityImpact": "PARTIAL", "baseScore": 5.2, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 5.1, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.7, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-12-26T01:15:16.220", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064090/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0076" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000064090/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0076" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-77" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Vendor | Product | Version | |
---|---|---|---|
netgear | rbr850_firmware | * | |
netgear | rbr850 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0B05A46-1FD0-4F51-857C-DA4F838C1A87", "versionEndExcluding": "3.2.10.11", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*", "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "NETGEAR RBR850 devices before 3.2.10.11 are affected by authentication bypass." }, { "lang": "es", "value": "Los dispositivos NETGEAR RBR850 versiones anteriores a 3.2.10.11, est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n" } ], "id": "CVE-2021-29065", "lastModified": "2024-11-21T06:00:37.803", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 8.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:A/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "cve@mitre.org", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.6, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 6.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-03-23T07:15:12.873", "references": [ { "source": "cve@mitre.org", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://kb.netgear.com/000063006/Security-Advisory-for-Authentication-Bypass-on-RBR850-PSV-2020-0029" } ], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }