FKIE_CVE-2021-45671

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7",
              "versionEndExcluding": "1.0.4.120",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
              "versionEndExcluding": "1.0.6.110",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
              "versionEndExcluding": "1.0.2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
              "versionEndExcluding": "1.0.2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF",
              "versionEndExcluding": "1.0.4.120",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
              "versionEndExcluding": "1.0.6.110",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
              "versionEndExcluding": "1.0.2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6",
              "versionEndExcluding": "1.0.2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6",
              "versionEndExcluding": "1.0.4.120",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
              "versionEndExcluding": "2.5.0.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2",
              "versionEndExcluding": "1.0.1.62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741",
              "versionEndExcluding": "1.0.4.38",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199",
              "versionEndExcluding": "1.0.4.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX80 versiones anteriores a 1.0.1.62, EX7500 versiones anteriores a 1.0.0.72, R7900 versiones anteriores a 1.0.4.38, R8000 versiones anteriores a 1.0.4. 68, RAX200 versiones anteriores a 1.0.4.120, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, MR60 versiones anteriores a 1.0.6.110, RAX20 versiones anteriores a 1.0.2.82, RAX45 versiones anteriores a 1.0.2. 72, RAX80 versiones anteriores a 1.0.4.120, MS60 versiones anteriores a 1.0.6.110, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1.0.2.72, RAX75 versiones anteriores a 1.0.4.120, RBR750 versiones anteriores a 3. 2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
    }
  ],
  "id": "CVE-2021-45671",
  "lastModified": "2024-11-21T06:32:50.550",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.3,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:21.057",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45670

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA",
              "versionEndExcluding": "1.0.3.106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
              "versionEndExcluding": "1.0.6.110",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
              "versionEndExcluding": "1.0.2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
              "versionEndExcluding": "1.0.2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182",
              "versionEndExcluding": "1.0.3.106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
              "versionEndExcluding": "1.0.6.110",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
              "versionEndExcluding": "1.0.2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6",
              "versionEndExcluding": "1.0.2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C",
              "versionEndExcluding": "1.0.3.106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
              "versionEndExcluding": "2.5.0.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B",
              "versionEndExcluding": "1.0.0.48",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5",
              "versionEndExcluding": "1.0.1.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
              "versionEndExcluding": "1.0.0.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
              "versionEndExcluding": "1.0.0.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3",
              "versionEndExcluding": "1.0.11.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423",
              "versionEndExcluding": "1.3.2.126",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741",
              "versionEndExcluding": "1.0.4.38",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199",
              "versionEndExcluding": "1.0.4.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C",
              "versionEndExcluding": "1.3.2.126",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, R7000 versiones anteriores a 1.0.11 116, R7900 versiones anteriores a 1.0.4.38, R8000 versiones anteriores a 1.0.4.68, RAX200 versiones anteriores a 1.0.3.106, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.6.110, R7000P versiones anteriores a 1.3.2. 126, RAX20 versiones anteriores a 1.0.2.82, RAX45 versiones anteriores a 1.0.2.72, RAX80 versiones anteriores a 1.0.3.106, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.6.110, R6900P versiones anteriores a 1.3.2.126, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1. 0.2.72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
    }
  ],
  "id": "CVE-2021-45670",
  "lastModified": "2024-11-21T06:32:50.360",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.3,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:21.007",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45666

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5",
              "versionEndExcluding": "1.0.1.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
              "versionEndExcluding": "1.0.0.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
              "versionEndExcluding": "1.0.0.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
              "versionEndExcluding": "2.5.0.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX80 versiones anteriores a 1.0.1.64, EX3700 versiones anteriores a 1.0.0.90, EX3800 versiones anteriores a 1.0.0.90, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, RBW30 versiones anteriores a 2. 6.1.4, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4"
    }
  ],
  "id": "CVE-2021-45666",
  "lastModified": "2024-11-21T06:32:49.713",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.3,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:20.827",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45667

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
              "versionEndExcluding": "2.5.0.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B",
              "versionEndExcluding": "1.0.0.48",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5",
              "versionEndExcluding": "1.0.1.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
              "versionEndExcluding": "1.0.0.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
              "versionEndExcluding": "1.0.0.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77",
              "versionEndExcluding": "1.4.1.66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA",
              "versionEndExcluding": "1.0.3.106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
              "versionEndExcluding": "1.0.6.110",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45",
              "versionEndExcluding": "1.4.1.66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
              "versionEndExcluding": "1.0.2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
              "versionEndExcluding": "1.0.2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182",
              "versionEndExcluding": "1.0.3.106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
              "versionEndExcluding": "1.0.6.110",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA",
              "versionEndExcluding": "1.4.1.66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
              "versionEndExcluding": "1.0.2.82",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3DD37BF-8664-412F-9A71-58880AF20242",
              "versionEndIncluding": "1.0.2.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C",
              "versionEndExcluding": "1.0.3.106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, R7960P versiones anteriores a 1. 4.1.66, RAX200 versiones anteriores a 1.0.3.106, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.6.110, R8000P versiones anteriores a 1.4.1.66, RAX20 versiones anteriores a 1.0.2. 82, RAX45 versiones anteriores a 1.0.2.72, RAX80 versiones anteriores a 1.0.3.106, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.6.110, R7900P versiones anteriores a 1.4.1.66, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1.0.2. 72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
    }
  ],
  "id": "CVE-2021-45667",
  "lastModified": "2024-11-21T06:32:49.870",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.3,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:20.870",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45665

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746",
              "versionEndExcluding": "1.0.0.36",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2",
              "versionEndExcluding": "1.0.1.62",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
              "versionEndExcluding": "1.0.0.90",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
              "versionEndExcluding": "1.0.0.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
              "versionEndExcluding": "1.0.0.44",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
              "versionEndExcluding": "3.2.16.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a EAX20 versiones anteriores a 1.0.0.36, EAX80 versiones anteriores a 1.0.1.62, EX3700 versiones anteriores a 1.0.0.90, EX3800 versiones anteriores a 1.0.0.90, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, RBW30 versiones anteriores a 2.6.1.4, RBW40V versiones anteriores a 2.6.1.4. 6.1.4, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4"
    }
  ],
  "id": "CVE-2021-45665",
  "lastModified": "2024-11-21T06:32:49.553",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 0.7,
        "impactScore": 5.3,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 1.7,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:20.780",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45628

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
              "versionEndExcluding": "2.5.0.24",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCDDC785-6FEC-4D94-86D1-8E55FB0CA6C1",
              "versionEndExcluding": "3.2.18.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B",
              "versionEndExcluding": "2.6.2.4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:2.6.2.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "62E0BEB9-020B-49C0-AF0D-A874CE9AD8B3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7",
              "versionEndExcluding": "2.6.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 3.2.18.2, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2. 17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBS40V versiones anteriores a 2.6.2.4 y RBW30 versiones anteriores a 2.6.2.2"
    }
  ],
  "id": "CVE-2021-45628",
  "lastModified": "2024-11-21T06:32:43.157",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.6,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 6.0,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:19.097",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45638

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADF65DC4-51D5-4C38-B28D-7EA93B1734A3",
              "versionEndExcluding": "1.0.0.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "888A8E0F-93DD-436D-B00C-F469C3BD6E5B",
              "versionEndExcluding": "1.0.0.102",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2D1C234-22F1-4837-9D04-059170A97072",
              "versionEndExcluding": "1.0.0.74",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "160F53B0-8430-4D85-8ABC-0A64B27DDFBD",
              "versionEndExcluding": "1.0.3.60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E0F22CB-81AF-4721-B5D0-426A0B356EBA",
              "versionEndExcluding": "1.0.0.56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FC74970-ACD5-482D-91C7-C46246E0BDC0",
              "versionEndExcluding": "1.0.4.50",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "930E739E-EFDC-49AB-9155-A71C2B25FCD6",
              "versionEndExcluding": "1.0.1.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3",
              "versionEndExcluding": "1.0.11.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "133FB073-4947-4146-974D-65347F6FA178",
              "versionEndExcluding": "1.0.0.70",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EAF3EA40-79FB-4D2C-A8AF-A04820745C4D",
              "versionEndExcluding": "1.3.2.132",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E56DEEC-4A36-4B33-951A-049D2582F7A4",
              "versionEndExcluding": "2.6.2.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7",
              "versionEndExcluding": "2.6.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A",
              "versionEndExcluding": "1.5.1.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "839A9EBE-5F14-4695-8040-7D5607F8E248",
              "versionEndExcluding": "1.3.2.132",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un atacante no autenticado. Esto afecta a D6220 versiones anteriores a 1.0.0.68, D6400 versiones anteriores a 1.0.0.102, D7000v2 versiones anteriores a 1.0.0.74, D8500 versiones anteriores a 1.0.3.60, DC112A versiones anteriores a 1.0.0.56, R6300v2 versiones anteriores a 1.0.4.50, R6400 versiones anteriores a 1.0. 1.68, R7000 versiones anteriores a 1.0.11.116, R7100LG versiones anteriores a 1.0.0.70, RBS40V versiones anteriores a 2.6.2.8, RBW30 versiones anteriores a 2.6.2.2, RS400 versiones anteriores a 1.5.1.80, R7000P versiones anteriores a 1.3.2.132 y R6900P versiones anteriores a 1.3.2.132"
    }
  ],
  "id": "CVE-2021-45638",
  "lastModified": "2024-11-21T06:32:44.717",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.6,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 6.0,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:19.550",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45527

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
Impacted products
Vendor Product Version
netgear rbk752_firmware *
netgear rbk752 -
netgear rbr750_firmware *
netgear rbr750 -
netgear rbs750_firmware *
netgear rbs750 -
netgear rbk852_firmware *
netgear rbk852 -
netgear rbr850_firmware *
netgear rbr850 -
netgear rbs850_firmware *
netgear rbs850 -
netgear d6220_firmware *
netgear d6220 -
netgear d6400_firmware *
netgear d6400 -
netgear d7000v2_firmware *
netgear d7000v2 -
netgear d8500_firmware *
netgear d8500 -
netgear dc112a_firmware *
netgear dc112a -
netgear ex7000_firmware *
netgear ex7000 -
netgear ex7500_firmware *
netgear ex7500 -
netgear r6250_firmware *
netgear r6250 -
netgear r6300v2_firmware *
netgear r6300v2 -
netgear r6400_firmware *
netgear r6400 -
netgear r6400v2_firmware *
netgear r6400v2 -
netgear r6700v3_firmware *
netgear r6700v3 -
netgear r7000_firmware *
netgear r7000 -
netgear r7100lg_firmware *
netgear r7100lg -
netgear r7850_firmware *
netgear r7850 -
netgear r7900_firmware *
netgear r7900 -
netgear r7960p_firmware *
netgear r7960p -
netgear r8000_firmware *
netgear r8000 -
netgear rax200_firmware *
netgear rax200 -
netgear rax75_firmware *
netgear rax75 -
netgear rax80_firmware *
netgear rax80 -
netgear rbs40v_firmware *
netgear rbs40v -
netgear xr300_firmware *
netgear xr300 -
netgear rs400_firmware *
netgear rs400 -
netgear r7000p_firmware *
netgear r7000p -
netgear r8000p_firmware *
netgear r8000p -
netgear r8500_firmware *
netgear r8500 -
netgear r6900p_firmware *
netgear r6900p -
netgear r7900p_firmware *
netgear r7900p -
netgear r8300_firmware *
netgear r8300 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d6220_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADF65DC4-51D5-4C38-B28D-7EA93B1734A3",
              "versionEndExcluding": "1.0.0.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d6220:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3EEA190-2E9C-4586-BF81-B115532FBA23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "888A8E0F-93DD-436D-B00C-F469C3BD6E5B",
              "versionEndExcluding": "1.0.0.102",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d6400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D30939B-86E3-4C78-9B05-686B4994C8B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB6EE3C6-6BA3-4D37-B43B-B98E6EDFDD41",
              "versionEndExcluding": "1.0.0.66",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:d8500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E1D0A84-92A5-4E07-B2BB-ED4431E64457",
              "versionEndExcluding": "1.0.3.58",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:d8500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "814A0114-9A1D-4EA0-9AF4-6968514E4F01",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:dc112a_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A59578F-1A3F-428B-A995-572C8E93C15C",
              "versionEndExcluding": "1.0.0.54",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:dc112a:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F87FFC46-137D-45B8-B437-F15565FB33D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5E273CF7-2DB6-4641-8753-810949D631B0",
              "versionEndExcluding": "1.0.1.94",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6250_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "049629DD-9E4F-4F47-98B0-C9FD457B74A0",
              "versionEndExcluding": "1.0.4.48",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6250:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "321BE843-52C4-4638-A321-439CA7B3A6F2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6300v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E00ABB7-A3E9-4E41-82CB-3AADC276C3AC",
              "versionEndExcluding": "1.0.4.52",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6300v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7909744D-FE9B-49D1-ADB3-029CCC432A47",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA1BB56F-20B5-4A79-AE9D-429A011EAA4C",
              "versionEndExcluding": "1.0.1.70",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E4CDF6B-3829-44D0-9675-71D7BE83CAA2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "19E991D4-ADE8-4EFC-A405-DBAF07FFEB21",
              "versionEndExcluding": "1.0.4.102",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "611768C9-4B1D-42CC-97CF-78D05EA332AC",
              "versionEndExcluding": "1.0.4.102",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3",
              "versionEndExcluding": "1.0.11.116",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1AC36017-5BCF-4CF6-91D0-278279943847",
              "versionEndExcluding": "1.0.0.64",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF7A1DF8-E9A0-4312-AC37-DEB46E37EE50",
              "versionEndExcluding": "1.0.5.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6364559-B141-43AE-B40A-506B79BCC3AA",
              "versionEndExcluding": "1.0.4.30",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0ECEE38A-B0BB-43F8-AB4D-26572B789BFB",
              "versionEndExcluding": "1.4.1.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D444B09-82DA-4225-A292-B28232408A7B",
              "versionEndExcluding": "1.0.4.52",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "609B0EC8-FCD3-4522-A06A-7CB521586A22",
              "versionEndExcluding": "1.0.2.88",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66",
              "versionEndExcluding": "1.0.3.102",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976",
              "versionEndExcluding": "1.0.3.102",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B",
              "versionEndExcluding": "2.6.2.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AF96D62-1D28-4FE5-AFC3-FB93A1BB4D45",
              "versionEndExcluding": "1.0.3.56",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A",
              "versionEndExcluding": "1.5.1.80",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C6F506A-464D-4BDE-8F9B-D537D3C7E137",
              "versionEndExcluding": "1.3.2.124",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61DF6302-36B7-49CF-8F2C-4C2247112EB9",
              "versionEndExcluding": "1.4.1.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8E565CF-8408-4502-97BD-01CEF15D0744",
              "versionEndExcluding": "1.0.2.144",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61DE3850-1661-43D1-9E52-31E2E01979EE",
              "versionEndExcluding": "1.3.2.124",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAB3F350-9094-4B64-8ED9-517069EB56F4",
              "versionEndExcluding": "1.4.1.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "60634A15-B02A-4C33-A1A4-F6340CFD6B8B",
              "versionEndExcluding": "1.0.2.144",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer por parte de un usuario autenticado. Esto afecta a D6220 versiones anteriores a 1.0.0.68, al D6400 versiones anteriores a 1.0.0.102, a D7000v2 versiones anteriores a 1.0.0.66, al D8500 versiones anteriores a 1.0.3.58, al DC112A versiones anteriores a 1.0.0.54, a EX7000 versiones anteriores a 1.0.1.94, a EX7500 versiones anteriores a 1.0.0.72, a R6250 versiones anteriores a 1.0.4.48, a R6300v2 versiones anteriores a 1. 0.4.52, R6400 versiones anteriores a 1.0.1.70, R6400v2 versiones anteriores a 1.0.4.102, R6700v3 versiones anteriores a 1.0.4.102, R7000 versiones anteriores a 1.0.11.116, R7100LG versiones anteriores a 1.0.0.64, R7850 versiones anteriores a 1.0.5.68, R7900 versiones anteriores a 1.0.4.30, R7960P versiones anteriores a 1.4.1.68, R8000 versiones anteriores a 1.0.4. 52, RAX200 versiones anteriores a 1.0.2.88, RBS40V versiones anteriores a 2.6.2.4, RS400 versiones anteriores a 1.5.1.80, XR300 versiones anteriores a 1.0.3.56, R7000P versiones anteriores a 1.3.2.124, R8000P versiones anteriores a 1.4.1.68, R8500 versiones anteriores a 1.0.2.144, RAX80 versiones anteriores a 1.0.3.102, R6900P versiones anteriores a 1.3.2. 124, R7900P versiones anteriores a 1.4.1.68, R8300 versiones anteriores a 1.0.2.144, RAX75 versiones anteriores a 1.0.3.102, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3.2.17.12 y RBK852 versiones anteriores a 3.2.17.12"
    }
  ],
  "id": "CVE-2021-45527",
  "lastModified": "2024-11-21T06:32:25.610",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.6,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 6.0,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:14.207",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45507

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
              "versionEndExcluding": "2.5.0.24",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
              "versionEndExcluding": "4.6.3.6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7",
              "versionEndExcluding": "2.6.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E56DEEC-4A36-4B33-951A-049D2582F7A4",
              "versionEndExcluding": "2.6.2.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBW30 versiones anteriores a 2.6.2.2, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17. 12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12 y RBS40V versiones anteriores a 2.6.2.8"
    }
  ],
  "id": "CVE-2021-45507",
  "lastModified": "2024-11-21T06:32:22.423",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.6,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 6.0,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:13.230",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2021-45515

Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Summary
Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
              "versionEndExcluding": "1.0.0.72",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
              "versionEndExcluding": "2.6.1.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbke963_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D52E6698-739A-4CD2-9FF4-37BB26641A84",
              "versionEndExcluding": "6.0.3.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbke963:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A373427-186D-4741-9751-211FA26DA3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbre960_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "49A5CF62-650B-4579-8527-F1D876D7D8B7",
              "versionEndExcluding": "6.0.3.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbre960:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "314FF95E-5A0C-4A6B-B8D6-28546F2C1A12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbse960_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A33F65C-6916-479C-B5F7-FCA5C158A213",
              "versionEndExcluding": "6.0.3.68",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbse960:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "419AF785-61C6-4911-A170-6A06D7991948",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
              "versionEndExcluding": "3.2.17.12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una denegaci\u00f3n de servicio. Esto afecta a EX7500 versiones anteriores a 1.0.0.72, a RBS40V versiones anteriores a 2.6.1.4, a RBW30 versiones anteriores a 2.6.1.4, a RBRE960 versiones anteriores a 6.0.3.68, a RBSE960 versiones anteriores a 6.0.3.68, a RBR750 versiones anteriores a 3.2.17.12, a RBR850 versiones anteriores a 3.2.10.11. 2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3.2.17.12 y RBK852 versiones anteriores a 3.2.17.12"
    }
  ],
  "id": "CVE-2021-45515",
  "lastModified": "2024-11-21T06:32:23.680",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 3.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "cve@mitre.org",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-12-26T01:15:13.627",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2021-45507 (GCVE-0-2021-45507)

Vulnerability from cvelistv5 – Published: 2021-12-26 01:02 – Updated: 2024-08-04 04:39
VLAI?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.394Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T01:02:10",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45507",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45507",
    "datePublished": "2021-12-26T01:02:10",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45515 (GCVE-0-2021-45515)

Vulnerability from cvelistv5 – Published: 2021-12-26 01:00 – Updated: 2024-08-04 04:39
VLAI?
Summary
Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.461Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T01:00:39",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45515",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45515",
    "datePublished": "2021-12-26T01:00:39",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.461Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45527 (GCVE-0-2021-45527)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:58 – Updated: 2024-08-04 04:39
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:58:02",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45527",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45527",
    "datePublished": "2021-12-26T00:58:02",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45628 (GCVE-0-2021-45628)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:33 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.676Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:33:39",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45628",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45628",
    "datePublished": "2021-12-26T00:33:39",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45638 (GCVE-0-2021-45638)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:31 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.775Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:31:28",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45638",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45638",
    "datePublished": "2021-12-26T00:31:28",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45665 (GCVE-0-2021-45665)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:26 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.863Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:26:16",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45665",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45665",
    "datePublished": "2021-12-26T00:26:16",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.863Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45666 (GCVE-0-2021-45666)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:26 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:26:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45666",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45666",
    "datePublished": "2021-12-26T00:26:06",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.842Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45667 (GCVE-0-2021-45667)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:25 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.865Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:25:53",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45667",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45667",
    "datePublished": "2021-12-26T00:25:53",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.865Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45670 (GCVE-0-2021-45670)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:25 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.773Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:25:17",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45670",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45670",
    "datePublished": "2021-12-26T00:25:17",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45671 (GCVE-0-2021-45671)

Vulnerability from cvelistv5 – Published: 2021-12-26 00:25 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.877Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:25:07",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45671",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45671",
    "datePublished": "2021-12-26T00:25:07",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.877Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45507 (GCVE-0-2021-45507)

Vulnerability from nvd – Published: 2021-12-26 01:02 – Updated: 2024-08-04 04:39
VLAI?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.394Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T01:02:10",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45507",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBW30 before 2.6.2.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and RBS40V before 2.6.2.8."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064131/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0487"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45507",
    "datePublished": "2021-12-26T01:02:10",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45515 (GCVE-0-2021-45515)

Vulnerability from nvd – Published: 2021-12-26 01:00 – Updated: 2024-08-04 04:39
VLAI?
Summary
Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.461Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T01:00:39",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45515",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by denial of service. This affects EX7500 before 1.0.0.72, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, RBRE960 before 6.0.3.68, RBSE960 before 6.0.3.68, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:N/I:N/PR:N/S:U/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064484/Security-Advisory-for-Denial-of-Service-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0286"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45515",
    "datePublished": "2021-12-26T01:00:39",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.461Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45527 (GCVE-0-2021-45527)

Vulnerability from nvd – Published: 2021-12-26 00:58 – Updated: 2024-08-04 04:39
VLAI?
Summary
Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:39:21.497Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:58:02",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45527",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.66, D8500 before 1.0.3.58, DC112A before 1.0.0.54, EX7000 before 1.0.1.94, EX7500 before 1.0.0.72, R6250 before 1.0.4.48, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.102, R6700v3 before 1.0.4.102, R7000 before 1.0.11.116, R7100LG before 1.0.0.64, R7850 before 1.0.5.68, R7900 before 1.0.4.30, R7960P before 1.4.1.68, R8000 before 1.0.4.52, RAX200 before 1.0.2.88, RBS40V before 2.6.2.4, RS400 before 1.5.1.80, XR300 before 1.0.3.56, R7000P before 1.3.2.124, R8000P before 1.4.1.68, R8500 before 1.0.2.144, RAX80 before 1.0.3.102, R6900P before 1.3.2.124, R7900P before 1.4.1.68, R8300 before 1.0.2.144, RAX75 before 1.0.3.102, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064493/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0437"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45527",
    "datePublished": "2021-12-26T00:58:02",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:39:21.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45628 (GCVE-0-2021-45628)

Vulnerability from nvd – Published: 2021-12-26 00:33 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.676Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:33:39",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45628",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45628",
    "datePublished": "2021-12-26T00:33:39",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.676Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45638 (GCVE-0-2021-45638)

Vulnerability from nvd – Published: 2021-12-26 00:31 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.775Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.6,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:31:28",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45638",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an unauthenticated attacker. This affects D6220 before 1.0.0.68, D6400 before 1.0.0.102, D7000v2 before 1.0.0.74, D8500 before 1.0.3.60, DC112A before 1.0.0.56, R6300v2 before 1.0.4.50, R6400 before 1.0.1.68, R7000 before 1.0.11.116, R7100LG before 1.0.0.70, RBS40V before 2.6.2.8, RBW30 before 2.6.2.2, RS400 before 1.5.1.80, R7000P before 1.3.2.132, and R6900P before 1.3.2.132."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:C/UI:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064496/Security-Advisory-for-Pre-Authentication-Stack-Overflow-on-Some-Routers-PSV-2020-0464"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45638",
    "datePublished": "2021-12-26T00:31:28",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.775Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45665 (GCVE-0-2021-45665)

Vulnerability from nvd – Published: 2021-12-26 00:26 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.863Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:26:16",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45665",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45665",
    "datePublished": "2021-12-26T00:26:16",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.863Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45666 (GCVE-0-2021-45666)

Vulnerability from nvd – Published: 2021-12-26 00:26 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:26:06",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45666",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45666",
    "datePublished": "2021-12-26T00:26:06",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.842Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45667 (GCVE-0-2021-45667)

Vulnerability from nvd – Published: 2021-12-26 00:25 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.865Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:25:53",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45667",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45667",
    "datePublished": "2021-12-26T00:25:53",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.865Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45670 (GCVE-0-2021-45670)

Vulnerability from nvd – Published: 2021-12-26 00:25 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.773Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:25:17",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45670",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45670",
    "datePublished": "2021-12-26T00:25:17",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.773Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-45671 (GCVE-0-2021-45671)

Vulnerability from nvd – Published: 2021-12-26 00:25 – Updated: 2024-08-04 04:47
VLAI?
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:47:01.877Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-26T00:25:07",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-45671",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AC:H/AV:A/A:L/C:L/I:H/PR:H/S:C/UI:R",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261",
              "refsource": "MISC",
              "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-45671",
    "datePublished": "2021-12-26T00:25:07",
    "dateReserved": "2021-12-25T00:00:00",
    "dateUpdated": "2024-08-04T04:47:01.877Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}