Search criteria
384 vulnerabilities found for rbs750_firmware by netgear
FKIE_CVE-2022-38452
Vulnerability from fkie_nvd - Published: 2023-03-21 18:15 - Updated: 2024-11-21 07:16
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rbs750_firmware | 4.6.8.5 | |
| netgear | rbs750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*",
"matchCriteriaId": "7CE366C8-EEC7-4725-AA02-C4ED5E204E01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability."
}
],
"id": "CVE-2022-38452",
"lastModified": "2024-11-21T07:16:30.377",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-03-21T18:15:12.193",
"references": [
{
"source": "talos-cna@cisco.com",
"url": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-912"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-38458
Vulnerability from fkie_nvd - Published: 2023-03-21 18:15 - Updated: 2024-11-21 07:16
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
Summary
A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rbs750_firmware | 4.6.8.5 | |
| netgear | rbs750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*",
"matchCriteriaId": "7CE366C8-EEC7-4725-AA02-C4ED5E204E01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information."
}
],
"id": "CVE-2022-38458",
"lastModified": "2024-11-21T07:16:31.003",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-03-21T18:15:12.267",
"references": [
{
"source": "talos-cna@cisco.com",
"url": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-311"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-319"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-37337
Vulnerability from fkie_nvd - Published: 2023-03-21 18:15 - Updated: 2024-11-21 07:14
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rbs750_firmware | 4.6.8.5 | |
| netgear | rbs750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*",
"matchCriteriaId": "7CE366C8-EEC7-4725-AA02-C4ED5E204E01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."
}
],
"id": "CVE-2022-37337",
"lastModified": "2024-11-21T07:14:47.110",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 6.0,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-03-21T18:15:12.097",
"references": [
{
"source": "talos-cna@cisco.com",
"url": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-36429
Vulnerability from fkie_nvd - Published: 2023-03-21 18:15 - Updated: 2024-11-21 07:12
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rbs750_firmware | 4.6.8.5 | |
| netgear | rbs750 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*",
"matchCriteriaId": "7CE366C8-EEC7-4725-AA02-C4ED5E204E01",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"id": "CVE-2022-36429",
"lastModified": "2024-11-21T07:12:59.513",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-03-21T18:15:11.970",
"references": [
{
"source": "talos-cna@cisco.com",
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-912"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2021-45671
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rax200_firmware | * | |
| netgear | rax200 | - | |
| netgear | mr60_firmware | * | |
| netgear | mr60 | - | |
| netgear | rax20_firmware | * | |
| netgear | rax20 | - | |
| netgear | rax45_firmware | * | |
| netgear | rax45 | - | |
| netgear | rax80_firmware | * | |
| netgear | rax80 | - | |
| netgear | ms60_firmware | * | |
| netgear | ms60 | - | |
| netgear | rax15_firmware | * | |
| netgear | rax15 | - | |
| netgear | rax50_firmware | * | |
| netgear | rax50 | - | |
| netgear | rax75_firmware | * | |
| netgear | rax75 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | cbr40_firmware | * | |
| netgear | cbr40 | - | |
| netgear | eax80_firmware | * | |
| netgear | eax80 | - | |
| netgear | ex7500_firmware | * | |
| netgear | ex7500 | - | |
| netgear | r7900_firmware | * | |
| netgear | r7900 | - | |
| netgear | r8000_firmware | * | |
| netgear | r8000 | - | |
| netgear | rbs40v_firmware | * | |
| netgear | rbs40v | - | |
| netgear | rbw30_firmware | * | |
| netgear | rbw30 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
"versionEndExcluding": "2.5.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2",
"versionEndExcluding": "1.0.1.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741",
"versionEndExcluding": "1.0.4.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199",
"versionEndExcluding": "1.0.4.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX80 versiones anteriores a 1.0.1.62, EX7500 versiones anteriores a 1.0.0.72, R7900 versiones anteriores a 1.0.4.38, R8000 versiones anteriores a 1.0.4. 68, RAX200 versiones anteriores a 1.0.4.120, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, MR60 versiones anteriores a 1.0.6.110, RAX20 versiones anteriores a 1.0.2.82, RAX45 versiones anteriores a 1.0.2. 72, RAX80 versiones anteriores a 1.0.4.120, MS60 versiones anteriores a 1.0.6.110, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1.0.2.72, RAX75 versiones anteriores a 1.0.4.120, RBR750 versiones anteriores a 3. 2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
}
],
"id": "CVE-2021-45671",
"lastModified": "2024-11-21T06:32:50.550",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 5.3,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:21.057",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45670
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
"versionEndExcluding": "2.5.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B",
"versionEndExcluding": "1.0.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5",
"versionEndExcluding": "1.0.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
"versionEndExcluding": "1.0.0.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
"versionEndExcluding": "1.0.0.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D9F1DAD0-F8B8-48D5-B571-C55636B274C3",
"versionEndExcluding": "1.0.11.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423",
"versionEndExcluding": "1.3.2.126",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "96390A31-03B8-477B-8710-F797CB44E741",
"versionEndExcluding": "1.0.4.38",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D10E41DC-982F-444A-9A4D-82EC2BA64199",
"versionEndExcluding": "1.0.4.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C",
"versionEndExcluding": "1.3.2.126",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7000 before 1.0.11.116, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R7000P before 1.3.2.126, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R6900P before 1.3.2.126, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, R7000 versiones anteriores a 1.0.11 116, R7900 versiones anteriores a 1.0.4.38, R8000 versiones anteriores a 1.0.4.68, RAX200 versiones anteriores a 1.0.3.106, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.6.110, R7000P versiones anteriores a 1.3.2. 126, RAX20 versiones anteriores a 1.0.2.82, RAX45 versiones anteriores a 1.0.2.72, RAX80 versiones anteriores a 1.0.3.106, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.6.110, R6900P versiones anteriores a 1.3.2.126, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1. 0.2.72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
}
],
"id": "CVE-2021-45670",
"lastModified": "2024-11-21T06:32:50.360",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 5.3,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:21.007",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064480/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0255"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45669
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
3.7 (Low) - CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | rax200_firmware | * | |
| netgear | rax200 | - | |
| netgear | mr60_firmware | * | |
| netgear | mr60 | - | |
| netgear | rax20_firmware | * | |
| netgear | rax20 | - | |
| netgear | rax45_firmware | * | |
| netgear | rax45 | - | |
| netgear | rax80_firmware | * | |
| netgear | rax80 | - | |
| netgear | ms60_firmware | * | |
| netgear | ms60 | - | |
| netgear | rax15_firmware | * | |
| netgear | rax15 | - | |
| netgear | rax50_firmware | * | |
| netgear | rax50 | - | |
| netgear | rax75_firmware | * | |
| netgear | rax75 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8B99059-161F-42D4-8AD8-478ABB7DE4B6",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a RAX200 versiones anteriores a 1.0.3.106, al MR60 versiones anteriores a 1.0.6.110, a RAX20 versiones anteriores a 1.0.2.82, a RAX45 versiones anteriores a 1.0.2.72, a RAX80 versiones anteriores a 1.0.3.106, al MS60 versiones anteriores a 1.0.6.110, a RAX15 versiones anteriores a 1.0.2.82, a RAX50 versiones anteriores a 1.0.2.72, a RBK752 versiones anteriores a 3.2.16.6 y a RBK852 versiones anteriores a 3.2.16.6. 0.2.72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6."
}
],
"id": "CVE-2021-45669",
"lastModified": "2024-11-21T06:32:50.190",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 2.7,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:20.960",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45665
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | eax20_firmware | * | |
| netgear | eax20 | - | |
| netgear | eax80_firmware | * | |
| netgear | eax80 | - | |
| netgear | ex3700_firmware | * | |
| netgear | ex3700 | - | |
| netgear | ex3800_firmware | * | |
| netgear | ex3800 | - | |
| netgear | ex6120_firmware | * | |
| netgear | ex6120 | - | |
| netgear | ex6130_firmware | * | |
| netgear | ex6130 | - | |
| netgear | ex7500_firmware | * | |
| netgear | ex7500 | - | |
| netgear | rbw30_firmware | * | |
| netgear | rbw30 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - | |
| netgear | rbs40v_firmware | * | |
| netgear | rbs40v | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62EFA314-85C0-48CC-938E-E2BF42B16746",
"versionEndExcluding": "1.0.0.36",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2",
"versionEndExcluding": "1.0.1.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
"versionEndExcluding": "1.0.0.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
"versionEndExcluding": "1.0.0.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a EAX20 versiones anteriores a 1.0.0.36, EAX80 versiones anteriores a 1.0.1.62, EX3700 versiones anteriores a 1.0.0.90, EX3800 versiones anteriores a 1.0.0.90, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, RBW30 versiones anteriores a 2.6.1.4, RBW40V versiones anteriores a 2.6.1.4. 6.1.4, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4"
}
],
"id": "CVE-2021-45665",
"lastModified": "2024-11-21T06:32:49.553",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 5.3,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:20.780",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064120/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0247"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45667
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
"versionEndExcluding": "2.5.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "42805332-33C3-49EB-9A55-952FA3E76A0B",
"versionEndExcluding": "1.0.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5",
"versionEndExcluding": "1.0.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
"versionEndExcluding": "1.0.0.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
"versionEndExcluding": "1.0.0.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77",
"versionEndExcluding": "1.4.1.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "04513F08-329D-446F-A356-29074C1C0BEA",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F1EBAB4-F713-4AC5-AECC-9E9D61FF3576",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45",
"versionEndExcluding": "1.4.1.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93EF1D39-E084-40E9-86CF-C590763841A0",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7932C371-669C-43C0-94A4-17BD4BDE8C74",
"versionEndExcluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "34D7AF28-F117-4E31-AED8-A3179B1BE182",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9E445DBA-2B45-410C-9288-1A4472452CE1",
"versionEndExcluding": "1.0.6.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA",
"versionEndExcluding": "1.4.1.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ED73C5EC-C8D3-4206-BCAA-0901F786DD98",
"versionEndExcluding": "1.0.2.82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E3DD37BF-8664-412F-9A71-58880AF20242",
"versionEndIncluding": "1.0.2.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C0318AD0-52A7-490F-94C1-D07C97370D2C",
"versionEndExcluding": "1.0.3.106",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.48, EAX80 before 1.0.1.64, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, R7960P before 1.4.1.66, RAX200 before 1.0.3.106, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, EX3700 before 1.0.0.90, MR60 before 1.0.6.110, R8000P before 1.4.1.66, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, EX3800 before 1.0.0.90, MS60 before 1.0.6.110, R7900P before 1.4.1.66, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.48, EAX80 versiones anteriores a 1.0.1.64, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, R7960P versiones anteriores a 1. 4.1.66, RAX200 versiones anteriores a 1.0.3.106, RBS40V versiones anteriores a 2.6.1.4, RBW30 versiones anteriores a 2.6.1.4, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.6.110, R8000P versiones anteriores a 1.4.1.66, RAX20 versiones anteriores a 1.0.2. 82, RAX45 versiones anteriores a 1.0.2.72, RAX80 versiones anteriores a 1.0.3.106, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.6.110, R7900P versiones anteriores a 1.4.1.66, RAX15 versiones anteriores a 1.0.2.82, RAX50 versiones anteriores a 1.0.2. 72, RAX75 versiones anteriores a 1.0.3.106, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
}
],
"id": "CVE-2021-45667",
"lastModified": "2024-11-21T06:32:49.870",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 5.3,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:20.870",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064481/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0256"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45666
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | eax80_firmware | * | |
| netgear | eax80 | - | |
| netgear | ex3700_firmware | * | |
| netgear | ex3700 | - | |
| netgear | ex3800_firmware | * | |
| netgear | ex3800 | - | |
| netgear | ex6120_firmware | * | |
| netgear | ex6120 | - | |
| netgear | ex6130_firmware | * | |
| netgear | ex6130 | - | |
| netgear | ex7500_firmware | * | |
| netgear | ex7500 | - | |
| netgear | rbw30_firmware | * | |
| netgear | rbw30 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - | |
| netgear | rbs40v_firmware | * | |
| netgear | rbs40v | - | |
| netgear | cbr40_firmware | * | |
| netgear | cbr40 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1344C924-0296-4F49-BF9F-113BB643CDD5",
"versionEndExcluding": "1.0.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
"versionEndExcluding": "1.0.0.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
"versionEndExcluding": "1.0.0.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F388398-842E-40B1-9ACC-2D9A15D2BF2A",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E2240C06-A117-48E6-9576-C58F3314A160",
"versionEndExcluding": "2.6.1.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
"versionEndExcluding": "2.5.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.64, EX3700 before 1.0.0.90, EX3800 before 1.0.0.90, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7500 before 1.0.0.72, RBW30 before 2.6.1.4, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, and RBS40V before 2.6.1.4."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS almacenado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX80 versiones anteriores a 1.0.1.64, EX3700 versiones anteriores a 1.0.0.90, EX3800 versiones anteriores a 1.0.0.90, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7500 versiones anteriores a 1.0.0.72, RBW30 versiones anteriores a 2. 6.1.4, RBK752 versiones anteriores a 3.2.16.6, RBR750 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBK852 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6 y RBS40V versiones anteriores a 2.6.1.4"
}
],
"id": "CVE-2021-45666",
"lastModified": "2024-11-21T06:32:49.713",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.7,
"impactScore": 5.3,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:20.827",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064121/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Extenders-and-WiFi-Systems-PSV-2020-0254"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45631
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr40_firmware | * | |
| netgear | cbr40 | - | |
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
"versionEndExcluding": "2.5.0.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45631",
"lastModified": "2024-11-21T06:32:43.630",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.233",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064136/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0504"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45632
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45632",
"lastModified": "2024-11-21T06:32:43.787",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.277",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064137/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0505"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45634
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45634",
"lastModified": "2024-11-21T06:32:44.103",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.367",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064139/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0515"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45639
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
5.2 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2B05686E-7206-4E3B-BDBD-05C8EA6CABB5",
"versionEndExcluding": "2.5.0.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "29F1DCF3-43BE-40C3-9BEF-00D4618611B4",
"versionEndExcluding": "1.0.0.32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C7EE6BC6-DEDA-4005-9E29-D66D0BC7E5C2",
"versionEndExcluding": "1.0.1.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9B9DB22D-0775-48CE-A97D-BA3B5873C9F8",
"versionEndExcluding": "1.0.0.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8C6DFDB6-1D7A-459A-8D30-FD4900ED718B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F747A14B-5331-428E-8B53-724090554E07",
"versionEndExcluding": "1.0.0.44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*",
"matchCriteriaId": "305E295C-9C73-4798-A0BE-7973E1EE5EAB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A2826A7E-990D-455A-8B16-CBCCC4633B97",
"versionEndExcluding": "1.0.1.104",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9F45B620-60B8-40F3-A055-181ADD71EFFF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3A9F4EEE-E2D2-42B2-BC5C-844055677C1C",
"versionEndExcluding": "1.0.0.72",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "82B05B23-A689-4A0A-8569-9FA7972EA663",
"versionEndExcluding": "1.0.11.110",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6364559-B141-43AE-B40A-506B79BCC3AA",
"versionEndExcluding": "1.0.4.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5B717BA8-81B7-470C-BF20-A4318D063D77",
"versionEndExcluding": "1.4.1.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A6C5E300-92E2-447A-822F-B95D1C59530E",
"versionEndExcluding": "1.0.4.62",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "49D5D1E8-637A-4970-8753-6A3FCA8FAC64",
"versionEndExcluding": "1.0.2.102",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D71EDB94-370B-46C3-A14E-3F3FB130DD49",
"versionEndExcluding": "1.0.3.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "20A423A5-04E9-4323-9818-6C9B78065103",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDAA5899-B73C-4690-853E-B5400F034BE1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3E18CCBB-46CD-423D-AA66-36F223EFD6E6",
"versionEndExcluding": "1.0.5.102",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "182AB5A2-5D07-4A5E-A863-4EE216D6F423",
"versionEndExcluding": "1.3.2.126",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "101031E9-479E-4F86-B83A-19376F8C8A45",
"versionEndExcluding": "1.4.1.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33505A97-35DB-4EFD-9D47-EA03057C8FFD",
"versionEndExcluding": "1.0.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61807742-C521-47BA-9285-667C58DDD86B",
"versionEndExcluding": "1.0.2.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "81DF924F-FDA4-4588-B8A3-6F18ABBD4976",
"versionEndExcluding": "1.0.3.102",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "850D0AE9-A57C-47D3-9D44-7EE24E6F594D",
"versionEndExcluding": "1.0.0.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5488D9-651C-4BAB-A141-06B816690D42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07A1D7A9-29E9-4B1D-90DB-24E0967C9BC7",
"versionEndExcluding": "1.0.5.102",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "44801589-B49E-4B00-84DD-EFE47526C70C",
"versionEndExcluding": "1.3.2.126",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "65F881E3-22B3-40D9-A896-51B13FD09EAA",
"versionEndExcluding": "1.4.1.66",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC5225D5-96AD-43EE-BAA3-37B7FEF97E86",
"versionEndExcluding": "1.0.1.64",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "989EB842-6F21-4814-9E03-AF52BBBEA7B9",
"versionEndExcluding": "1.0.2.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ADDF0077-E02C-4DDA-A84E-DF3A0237FC66",
"versionEndExcluding": "1.0.3.102",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "05A46FA9-5DC8-4408-B4C2-AD5F1CABE7C1",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FE13548D-0A26-45C1-8424-D4705EB105EA",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2C144D71-6C10-44CD-BFF9-907A92F0432C",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "041D94DE-78C9-475C-9FAE-0B081C69B55F",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FDD03FFF-ECAF-4527-A195-559DF479A0F2",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B66A716A-7EC5-4F9B-853A-36C0D1AA3BFE",
"versionEndExcluding": "3.2.16.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by reflected XSS. This affects CBR40 before 2.5.0.10, EAX20 before 1.0.0.32, EAX80 before 1.0.1.62, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.72, R7000 before 1.0.11.110, R7900 before 1.0.4.30, R7960P before 1.4.1.66, R8000 before 1.0.4.62, RAX200 before 1.0.2.102, XR300 before 1.0.3.50, EX3700 before 1.0.0.90, MR60 before 1.0.5.102, R7000P before 1.3.2.126, R8000P before 1.4.1.66, RAX20 before 1.0.1.64, RAX50 before 1.0.2.28, RAX80 before 1.0.3.102, EX3800 before 1.0.0.90, MS60 before 1.0.5.102, R6900P before 1.3.2.126, R7900P before 1.4.1.66, RAX15 before 1.0.1.64, RAX45 before 1.0.2.28, RAX75 before 1.0.3.102, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por un ataque de tipo XSS reflejado. Esto afecta a CBR40 versiones anteriores a 2.5.0.10, EAX20 versiones anteriores a 1.0.0.32, EAX80 versiones anteriores a 1.0.1.62, EX6120 versiones anteriores a 1.0.0.64, EX6130 versiones anteriores a 1.0.0.44, EX7000 versiones anteriores a 1.0.1.104, EX7500 versiones anteriores a 1.0.0.72, R7000 versiones anteriores a 1.0.11. 110, R7900 versiones anteriores a 1.0.4.30, R7960P versiones anteriores a 1.4.1.66, R8000 versiones anteriores a 1.0.4.62, RAX200 versiones anteriores a 1.0.2.102, XR300 versiones anteriores a 1.0.3.50, EX3700 versiones anteriores a 1.0.0.90, MR60 versiones anteriores a 1.0.5.102, R7000P versiones anteriores a 1.3.2.126, R8000P versiones anteriores a 1. 4.1.66, RAX20 versiones anteriores a 1.0.1.64, RAX50 versiones anteriores a 1.0.2.28, RAX80 versiones anteriores a 1.0.3.102, EX3800 versiones anteriores a 1.0.0.90, MS60 versiones anteriores a 1.0.5.102, R6900P versiones anteriores a 1.3.2.126, R7900P versiones anteriores a 1.4.1.66, RAX15 versiones anteriores a 1.0.1. 64, RAX45 versiones anteriores a 1.0.2.28, RAX75 versiones anteriores a 1.0.3.102, RBR750 versiones anteriores a 3.2.16.6, RBR850 versiones anteriores a 3.2.16.6, RBS750 versiones anteriores a 3.2.16.6, RBS850 versiones anteriores a 3.2.16.6, RBK752 versiones anteriores a 3.2.16.6 y RBK852 versiones anteriores a 3.2.16.6"
}
],
"id": "CVE-2021-45639",
"lastModified": "2024-11-21T06:32:44.890",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 2.7,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.597",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064460/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0121"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45635
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45635",
"lastModified": "2024-11-21T06:32:44.260",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.413",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064134/Security-Advisory-for-Pre-Authentication-Command-Injection-on-WiFi-Systems-PSV-2020-0491"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45630
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr40_firmware | * | |
| netgear | cbr40 | - | |
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
"versionEndExcluding": "2.5.0.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45630",
"lastModified": "2024-11-21T06:32:43.477",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.187",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064135/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0498"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45628
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr40_firmware | * | |
| netgear | cbr40 | - | |
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - | |
| netgear | rbs40v_firmware | * | |
| netgear | rbs40v_firmware | 2.6.2.4 | |
| netgear | rbs40v | - | |
| netgear | rbw30_firmware | * | |
| netgear | rbw30 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
"versionEndExcluding": "2.5.0.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DCDDC785-6FEC-4D94-86D1-8E55FB0CA6C1",
"versionEndExcluding": "3.2.18.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1CA086E1-DB23-4130-B746-D56F5A188C3B",
"versionEndExcluding": "2.6.2.4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:netgear:rbs40v_firmware:2.6.2.4:*:*:*:*:*:*:*",
"matchCriteriaId": "62E0BEB9-020B-49C0-AF0D-A874CE9AD8B3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs40v:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F0D05F28-47A2-46AE-992E-132B34F6194B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbw30_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8EF8E22-9DC7-4A42-99E0-A6822F647DF7",
"versionEndExcluding": "2.6.2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbw30:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FEA73D22-970D-45F2-81F3-9576C04CCC94",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBS40V before 2.6.2.4, and RBW30 before 2.6.2.2."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 3.2.18.2, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2. 17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBS40V versiones anteriores a 2.6.2.4 y RBW30 versiones anteriores a 2.6.2.2"
}
],
"id": "CVE-2021-45628",
"lastModified": "2024-11-21T06:32:43.157",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.097",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064125/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0472"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45633
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, and RBK852 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RBK752 versiones anteriores a 3.2.17.12 y RBK852 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45633",
"lastModified": "2024-11-21T06:32:43.943",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.323",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064511/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0514"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45629
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR750 versiones anteriores a 4.6.3.6, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45629",
"lastModified": "2024-11-21T06:32:43.320",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:19.143",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45613
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
"versionEndExcluding": "2.5.0.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:d7000v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C2D1C234-22F1-4837-9D04-059170A97072",
"versionEndExcluding": "1.0.0.74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:d7000v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6DC6BD34-1A2C-4247-A20C-0B44C0F56E0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0",
"versionEndExcluding": "1.1.6.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467",
"versionEndExcluding": "1.0.6.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*",
"matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465",
"versionEndExcluding": "1.0.6.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38",
"versionEndExcluding": "1.0.6.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*",
"matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38",
"versionEndExcluding": "1.0.0.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "29757651-068E-4646-AAD8-2CF8FD08B34C",
"versionEndExcluding": "1.1.2.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2A086E76-3F23-4C21-AC96-F11372A8A186",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1582E16D-ACEE-4E33-9D52-9DD25C035EA8",
"versionEndExcluding": "1.1.2.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE1A0669-790A-4EE7-A0DC-6E1023D6B4F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, D7000v2 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, MR80 before 1.1.2.20, MS80 before 1.1.2.20, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX43 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX35v2 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, and XR1000 before 1.0.0.58."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, D7000v2 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6. 116, MS60 versiones anteriores a 1.0.6.116, MR80 versiones anteriores a 1.1.2.20, MS80 versiones anteriores a 1.1.2.20, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX45 versiones anteriores a 1.0.3. 96, RAX50 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX35v2 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1.0.4.120, RBK752 versiones anteriores a 3. 2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, y XR1000 versiones anteriores a 1.0.0.58"
}
],
"id": "CVE-2021-45613",
"lastModified": "2024-11-21T06:32:40.303",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:18.383",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064138/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0508"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45615
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | cbr40_firmware | * | |
| netgear | cbr40 | - | |
| netgear | cbr750_firmware | * | |
| netgear | cbr750 | - | |
| netgear | r7900p_firmware | * | |
| netgear | r7900p | - | |
| netgear | r7960p_firmware | * | |
| netgear | r7960p | - | |
| netgear | r8000p_firmware | * | |
| netgear | r8000p | - | |
| netgear | r8300_firmware | * | |
| netgear | r8300 | - | |
| netgear | r8500_firmware | * | |
| netgear | r8500 | - | |
| netgear | rbk752_firmware | * | |
| netgear | rbk752 | - | |
| netgear | rbk852_firmware | * | |
| netgear | rbk852 | - | |
| netgear | rbr750_firmware | * | |
| netgear | rbr750 | - | |
| netgear | rbr850_firmware | * | |
| netgear | rbr850 | - | |
| netgear | rbs750_firmware | * | |
| netgear | rbs750 | - | |
| netgear | rbs850_firmware | * | |
| netgear | rbs850 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
"versionEndExcluding": "2.5.0.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19",
"versionEndExcluding": "1.4.2.84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA",
"versionEndExcluding": "1.4.2.84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E",
"versionEndExcluding": "1.4.2.84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "68D7FF2D-210A-4B16-B871-394413F64F3A",
"versionEndExcluding": "1.0.2.154",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7A9B77E7-7439-48C6-989F-5E22CB4D3044",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "45ADC486-2457-496D-B887-EAAB9833E160",
"versionEndExcluding": "1.0.2.154",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "63500DE4-BDBD-4F86-AB99-7DB084D0B912",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000P versiones anteriores a 1.4.2.84, R8300 versiones anteriores a 1.0.2.154, R8500 versiones anteriores a 1. 0.2.154, RBK752 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12 y RBS850 versiones anteriores a 3.2.17.12"
}
],
"id": "CVE-2021-45615",
"lastModified": "2024-11-21T06:32:40.773",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:18.473",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064514/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0521"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-45612
Vulnerability from fkie_nvd - Published: 2021-12-26 01:15 - Updated: 2024-11-21 06:32
Severity ?
9.6 (Critical) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr40_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7483E92A-5858-49B5-9499-E132941F5ACD",
"versionEndExcluding": "2.5.0.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr40:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE0F7E9E-196C-4106-B1C9-C16FA5910A0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:cbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A87D3ACB-B5A3-4F1F-BF46-73C0AD690D8C",
"versionEndExcluding": "4.6.3.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:cbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CBD14EFC-C6EF-485B-A594-73B8525704A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FCA48F47-FC18-4953-BA90-1F4F3695A2BE",
"versionEndExcluding": "1.0.0.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9D3B54B-33C0-4E50-AD2B-2097C612F288",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:eax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AC9EE9DE-DD58-46A9-87FB-D284EBE0ACC1",
"versionEndExcluding": "1.0.1.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:eax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97740F5D-063E-424F-A0FE-09EBE1100975",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ex7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0EB8CD19-4963-42A8-B9E6-63ED5EC35119",
"versionEndExcluding": "1.0.0.74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ex7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "44336289-F9DA-4779-8C1A-0221E29E2E2F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:lax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "48709EA4-81F3-4CF1-B9A8-5379309914B0",
"versionEndExcluding": "1.1.6.28",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:lax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "491CEB8D-22F3-4F86-96F0-03C5C58BA295",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mk62_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AE40C2D0-0863-4E0F-B3E7-6FD043B46467",
"versionEndExcluding": "1.0.6.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mk62:-:*:*:*:*:*:*:*",
"matchCriteriaId": "69A79475-37BE-47BD-A629-DCEF22500B0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:mr60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EA438541-75AE-4D6B-AB56-02760D08D465",
"versionEndExcluding": "1.0.6.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:mr60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65BB3ECD-2F0B-4625-A1DB-F6CEFC46E277",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:ms60_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2234C485-F411-48CC-9A0B-AA49B6961E38",
"versionEndExcluding": "1.0.6.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:ms60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F003F064-591C-4D7C-9EC4-D0E553BC6683",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6400v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0095B9D4-E161-4050-B283-2166CB86CB24",
"versionEndExcluding": "1.0.4.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6400v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AFE6B3A8-0601-44EA-AD9B-3BDDE6654FDF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6700v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0702F9B6-2DAC-4308-8737-9F85AD28E847",
"versionEndExcluding": "1.0.4.118",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6700v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C88DA385-5FAE-49EC-80D6-78F81E7EEC16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "94795476-184B-4E7D-9D8B-ECB45609108E",
"versionEndExcluding": "1.3.3.140",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A0E06EFF-9D71-43DB-A304-9A41998FD68A",
"versionEndExcluding": "1.0.11.126",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C3A7E8BF-8CC3-4806-89F5-FBE01A36A1FD",
"versionEndExcluding": "1.3.3.140",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8491F80C-E57A-4862-B969-F43799A47D06",
"versionEndExcluding": "1.0.5.74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DAF94D73-B6D0-4334-9A41-83AA92B7C6DF",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4195BC65-A849-4C3A-B726-E013CEB57F32",
"versionEndExcluding": "1.0.4.46",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C484840F-AF30-4B5C-821A-4DB9BE407BDB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7900p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EA344C08-94F1-47F8-9607-3D854B890E19",
"versionEndExcluding": "1.4.2.84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7900p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F3D6A70D-66AF-4064-9F1B-4358D4B1F016",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r7960p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33B2293C-09AD-4B5A-B2A0-923E2B9923AA",
"versionEndExcluding": "1.4.2.84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r7960p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "091CEDB5-0069-4253-86D8-B9FE17CB9F24",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A662FDCF-DC41-4DC9-B77E-BE1D636AC0B3",
"versionEndExcluding": "1.0.4.74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5B39F095-8FE8-43FD-A866-7B613B495984",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:r8000p_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4905D866-2326-487F-AAA5-96ABA0DBD56E",
"versionEndExcluding": "1.4.2.84",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:r8000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F7EF872D-2537-4FEB-8799-499FC9D44339",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax15_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2268D5EF-E7FA-4112-A468-507417E18FFF",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax15:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B624B4D3-BCF4-4F95-B401-A88BEC3145A5",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax20_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "31289572-2197-4A38-8353-CA4AAD491160",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax20:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7038703C-C79D-4DD4-8B16-E1A5FC6694C0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6334DE4D-E78B-4582-9C6F-6123DA5192C7",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "58EB0F2F-FB5C-47D9-9AE6-087AE517B3F9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax35v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "841D857C-3387-43E0-A3AF-0E81CBEE3E40",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax35v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9358B2F2-D24E-434D-AEE5-6CE093598793",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax40v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4FF0E5B9-8D2D-4A3F-881E-2E3122B3577C",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax40v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3CEAD12D-6D90-4CFB-9E59-2CEBD400C567",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax43_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8AC89EAA-344C-438E-A5A5-2C34CF699743",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax43:-:*:*:*:*:*:*:*",
"matchCriteriaId": "178BB386-F66C-4CE8-9283-37D22B304691",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax45_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0706367A-3F60-4564-8689-E0A46DDC31C2",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax45:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4B08BD69-CDCC-4CEB-B887-4E47D2B45D26",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax50_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "679C4EC5-D17E-469B-A28F-BF5E231CED3D",
"versionEndExcluding": "1.0.3.96",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax50:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C430976E-24C0-4EA7-BF54-F9C188AB9C01",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax75_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BDF9F3BA-4239-4F4D-A65E-A6752A5420F6",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax75:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1BAA74D7-36A1-4494-96A2-BD0D2D6BF22F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rax80_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "334BB384-5C29-4D24-9F82-B8EE8D0CA8BF",
"versionEndExcluding": "1.0.4.120",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rax80:-:*:*:*:*:*:*:*",
"matchCriteriaId": "06B5A85C-3588-4263-B9AD-4E56D3F6CB16",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk752_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D8D90FF3-F5CE-43DF-ACF7-C64DBDCCA185",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk752:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A45832BD-114D-42F1-B9F1-7532496D30A6",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbk852_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "845C1FCC-F54B-452A-B121-1CD1A7867027",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbk852:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14F257FE-31CE-4F74-829D-29407D74ADF7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6AE1767-9D9A-4E9E-B088-6727FACFDE5C",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C13F5C69-FA9B-472A-9036-0C2967BDCDE9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbr850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "01E0EF50-145F-407A-8915-4EFFCD833505",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbr850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D92E4C8E-222A-476C-8273-F7171FC61F0B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs750_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F614A1AB-F0C0-45D7-8D91-ECA3C1AA9165",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs750:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B529194C-C440-4BC3-850F-0613FC548F86",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rbs850_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0DC5A075-0619-409C-B057-41015B8C54B3",
"versionEndExcluding": "3.2.17.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rbs850:-:*:*:*:*:*:*:*",
"matchCriteriaId": "221CA950-E984-44CD-9E1B-3AADE3CEBE52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:rs400_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "95AF0FA9-F2C5-4D84-BF37-AA8CB6EC3C4A",
"versionEndExcluding": "1.5.1.80",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:rs400:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2700644E-0940-4D05-B3CA-904D91739E58",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr1000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "F615F516-29EF-4C15-9E18-C5D4F6291A38",
"versionEndExcluding": "1.0.0.58",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr1000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FD4ED11-4130-47DA-8A9D-55B8F6E3E213",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:xr300_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3AE70236-D1C6-4B58-8385-1FA5F71916AF",
"versionEndExcluding": "1.0.3.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:xr300:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5590CF28-B88A-4755-904B-1BC1778FBEDD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a CBR40 versiones anteriores a 2.5.0.24, CBR750 versiones anteriores a 4.6.3.6, EAX20 versiones anteriores a 1.0.0.58, EAX80 versiones anteriores a 1.0.1.68, EX7500 versiones anteriores a 1.0.0.74, LAX20 versiones anteriores a 1.1.6.28, MK62 versiones anteriores a 1.0.6.116, MR60 versiones anteriores a 1.0.6.116, MS60 versiones anteriores a 1.0.6.116, R6400v2 versiones anteriores a 1.0. 4.118, R6700v3 versiones anteriores a 1.0.4.118, R6900P versiones anteriores a 1.3.3.140, R7000 versiones anteriores a 1.0.11.126, R7000P versiones anteriores a 1.3.3.140, R7850 versiones anteriores a 1.0.5.74, R7900 versiones anteriores a 1.0.4.46, R7900P versiones anteriores a 1.4.2.84, R7960P versiones anteriores a 1.4.2.84, R8000 versiones anteriores a 1.0.4.74, R8000P versiones anteriores a 1. 4.2.84, RAX15 versiones anteriores a 1.0.3.96, RAX20 versiones anteriores a 1.0.3.96, RAX200 versiones anteriores a 1.0.4.120, RAX35v2 versiones anteriores a 1.0.3.96, RAX40v2 versiones anteriores a 1.0.3.96, RAX43 versiones anteriores a 1.0.3.96, RAX45 versiones anteriores a 1.0.3.96, RAX50 versiones anteriores a 1.0.3.96, RAX75 versiones anteriores a 1.0.4.120, RAX80 versiones anteriores a 1. 0.4.120, RBK752 versiones anteriores a 3.2.17.12, RBK852 versiones anteriores a 3.2.17.12, RBR750 versiones anteriores a 3.2.17.12, RBR850 versiones anteriores a 3.2.17.12, RBS750 versiones anteriores a 3.2.17.12, RBS850 versiones anteriores a 3.2.17.12, RS400 versiones anteriores a 1.5.1.80, XR1000 versiones anteriores a 1.0.0.58 y XR300 versiones anteriores a 1.0.3.68"
}
],
"id": "CVE-2021-45612",
"lastModified": "2024-11-21T06:32:40.110",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-12-26T01:15:18.337",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000064515/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Router-Extenders-and-WiFi-Systems-PSV-2020-0524"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2022-37337 (GCVE-0-2022-37337)
Vulnerability from cvelistv5 – Published: 2023-03-21 17:41 – Updated: 2025-02-26 16:12
VLAI?
Summary
A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
Severity ?
9.1 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Router RBR750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:29:20.981Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"name": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-37337",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T16:11:58.643713Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T16:12:07.056Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Router RBR750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:14:11.453Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"name": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187",
"url": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-37337",
"datePublished": "2023-03-21T17:41:26.101Z",
"dateReserved": "2022-08-23T17:48:50.665Z",
"dateUpdated": "2025-02-26T16:12:07.056Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38452 (GCVE-0-2022-38452)
Vulnerability from cvelistv5 – Published: 2023-03-21 17:41 – Updated: 2025-02-26 16:38
VLAI?
Summary
A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
Severity ?
7.2 (High)
CWE
- CWE-912 - Hidden Functionality
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Router RBR750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:54:03.510Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"name": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38452",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T16:37:53.257184Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T16:38:11.731Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Router RBR750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:13:38.314Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"name": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186",
"url": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-38452",
"datePublished": "2023-03-21T17:41:26.484Z",
"dateReserved": "2022-08-19T18:57:28.943Z",
"dateUpdated": "2025-02-26T16:38:11.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36429 (GCVE-0-2022-36429)
Vulnerability from cvelistv5 – Published: 2023-03-21 17:41 – Updated: 2024-08-03 10:07
VLAI?
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Severity ?
7.2 (High)
CWE
- CWE-912 - Hidden Functionality
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Satellite RBS750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:07:33.896Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rbs750_firmware",
"vendor": "netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36429",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T15:42:46.126213Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:52:41.065Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Satellite RBS750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:14:37.184Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-36429",
"datePublished": "2023-03-21T17:41:25.748Z",
"dateReserved": "2022-08-23T17:55:12.245Z",
"dateUpdated": "2024-08-03T10:07:33.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38458 (GCVE-0-2022-38458)
Vulnerability from cvelistv5 – Published: 2023-03-21 17:41 – Updated: 2025-02-26 16:16
VLAI?
Summary
A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information.
Severity ?
6.5 (Medium)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Router RBR750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:54:03.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"name": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38458",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T16:16:11.945127Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T16:16:18.651Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Router RBR750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-28T14:49:38.892Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"name": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189",
"url": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-38458",
"datePublished": "2023-03-21T17:41:25.364Z",
"dateReserved": "2022-08-23T17:57:51.673Z",
"dateUpdated": "2025-02-26T16:16:18.651Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-37337 (GCVE-0-2022-37337)
Vulnerability from nvd – Published: 2023-03-21 17:41 – Updated: 2025-02-26 16:12
VLAI?
Summary
A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability.
Severity ?
9.1 (Critical)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Router RBR750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:29:20.981Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"name": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-37337",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T16:11:58.643713Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T16:12:07.056Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Router RBR750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the access control functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:14:11.453Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1596"
},
{
"name": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187",
"url": "https://kb.netgear.com/000065417/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0187"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-37337",
"datePublished": "2023-03-21T17:41:26.101Z",
"dateReserved": "2022-08-23T17:48:50.665Z",
"dateUpdated": "2025-02-26T16:12:07.056Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38452 (GCVE-0-2022-38452)
Vulnerability from nvd – Published: 2023-03-21 17:41 – Updated: 2025-02-26 16:38
VLAI?
Summary
A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability.
Severity ?
7.2 (High)
CWE
- CWE-912 - Hidden Functionality
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Router RBR750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:54:03.510Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"name": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38452",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T16:37:53.257184Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T16:38:11.731Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Router RBR750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the hidden telnet service functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted network request can lead to arbitrary command execution. An attacker can send a network request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:13:38.314Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1595"
},
{
"name": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186",
"url": "https://kb.netgear.com/000065567/Security-Advisory-for-Post-authentication-Command-Injection-on-the-RBR750-PSV-2022-0186"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-38452",
"datePublished": "2023-03-21T17:41:26.484Z",
"dateReserved": "2022-08-19T18:57:28.943Z",
"dateUpdated": "2025-02-26T16:38:11.731Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-36429 (GCVE-0-2022-36429)
Vulnerability from nvd – Published: 2023-03-21 17:41 – Updated: 2024-08-03 10:07
VLAI?
Summary
A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability.
Severity ?
7.2 (High)
CWE
- CWE-912 - Hidden Functionality
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Satellite RBS750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:07:33.896Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:netgear:rbs750_firmware:4.6.8.5:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "rbs750_firmware",
"vendor": "netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-36429",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T15:42:46.126213Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T15:52:41.065Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Satellite RBS750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A command execution vulnerability exists in the ubus backend communications functionality of Netgear Orbi Satellite RBS750 4.6.8.5. A specially-crafted JSON object can lead to arbitrary command execution. An attacker can send a sequence of malicious packets to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-912",
"description": "CWE-912: Hidden Functionality",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-29T10:14:37.184Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1597"
},
{
"name": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188",
"url": "https://kb.netgear.com/000065424/Security-Advisory-for-Command-Injection-on-Some-Orbi-WiFi-Systems-PSV-2022-0188"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-36429",
"datePublished": "2023-03-21T17:41:25.748Z",
"dateReserved": "2022-08-23T17:55:12.245Z",
"dateUpdated": "2024-08-03T10:07:33.896Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38458 (GCVE-0-2022-38458)
Vulnerability from nvd – Published: 2023-03-21 17:41 – Updated: 2025-02-26 16:16
VLAI?
Summary
A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information.
Severity ?
6.5 (Medium)
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Netgear | Orbi Router RBR750 |
Affected:
4.6.8.5
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:54:03.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"name": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189",
"tags": [
"x_transferred"
],
"url": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38458",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-26T16:16:11.945127Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-26T16:16:18.651Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Orbi Router RBR750",
"vendor": "Netgear",
"versions": [
{
"status": "affected",
"version": "4.6.8.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A cleartext transmission vulnerability exists in the Remote Management functionality of Netgear Orbi Router RBR750 4.6.8.5. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-28T14:49:38.892Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1598"
},
{
"name": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189",
"url": "https://kb.netgear.com/000065428/Security-Advisory-for-Cleartext-Transmission-on-Some-Orbi-WiFi-Systems-PSV-2022-0189"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-38458",
"datePublished": "2023-03-21T17:41:25.364Z",
"dateReserved": "2022-08-23T17:57:51.673Z",
"dateUpdated": "2025-02-26T16:16:18.651Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}