All the vulnerabilites related to mitsubishielectric - rd78g4
cve-2020-14523
Vulnerability from cvelistv5
Published
2022-02-11 17:40
Modified
2024-09-16 23:36
Severity ?
EPSS score ?
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | x_refsource_MISC | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | x_refsource_MISC | |
https://jvn.jp/vu/JVNVU90224831/ | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Mitsubishi Electric | CW Configurator |
Version: unspecified < |
||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.640Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU90224831/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "CW Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.010L", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "FR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.22Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "GX Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.595V", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "GX Works3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.063R", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSOFT iQ AppPortal", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.17T", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSOFT Navigator", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version2.70Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MI Configurator", "vendor": "Mitsubishi Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "product": "MR Configurator2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 1.110Q", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MT Works2", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.156N", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MX Component", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Version 4.20W", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "RT ToolBox3", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 1.70Y", "status": "affected", "version": "unspecified", "versionType": "custom" } ] }, { "product": "MELSEC iQ-R Series Motion Module", "vendor": "Mitsubishi Electric", "versions": [ { "lessThanOrEqual": "Versions 10", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "datePublic": "2020-07-30T00:00:00", "descriptions": [ { "lang": "en", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-02-18T23:17:23", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU90224831/" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" }, "title": "Mitsubishi Electric Factory Automation Products Path Traversal", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-30T16:50:00.000Z", "ID": "CVE-2020-14523", "STATE": "PUBLIC", "TITLE": "Mitsubishi Electric Factory Automation Products Path Traversal" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "CW Configurator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.010L" } ] } }, { "product_name": "FR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.22Y" } ] } }, { "product_name": "GX Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.595V" } ] } }, { "product_name": "GX Works3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.063R" } ] } }, { "product_name": "MELSOFT iQ AppPortal", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.17T" } ] } }, { "product_name": "MELSOFT Navigator", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version2.70Y" } ] } }, { "product_name": "MI Configurator", "version": { "version_data": [ { "version_affected": "=", "version_value": "All Versions" } ] } }, { "product_name": "MR Configurator2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 1.110Q" } ] } }, { "product_name": "MT Works2", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 1.156N" } ] } }, { "product_name": "MX Component", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Version 4.20W" } ] } }, { "product_name": "RT ToolBox3", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 1.70Y" } ] } }, { "product_name": "MELSEC iQ-R Series Motion Module", "version": { "version_data": [ { "version_affected": "\u003c=", "version_value": "Versions 10" } ] } } ] }, "vendor_name": "Mitsubishi Electric" } ] } }, "credit": [ { "lang": "eng", "value": "Mashav Sapir of Claroty reported this vulnerability to CISA" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "name": "https://jvn.jp/vu/JVNVU90224831/", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU90224831/" } ] }, "solution": [ { "lang": "en" } ], "source": { "advisory": "ICSA-20-212-03", "discovery": "UNKNOWN" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14523", "datePublished": "2022-02-11T17:40:29.187685Z", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-09-16T23:36:20.299Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-02-11 18:15
Modified
2024-11-21 05:03
Severity ?
8.3 (High) - CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://jvn.jp/vu/JVNVU90224831/ | Third Party Advisory | |
ics-cert@hq.dhs.gov | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | Patch, Third Party Advisory, US Government Resource | |
ics-cert@hq.dhs.gov | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU90224831/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03 | Patch, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf | Vendor Advisory |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:mitsubishielectric:cw_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "892E3CDC-AFC4-4EF1-AF46-3F161603DDB1", "versionEndIncluding": "1.010l", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "87549502-D224-408D-8C66-41F5E8F7743A", "versionEndIncluding": "1.22y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "015EB163-A5D6-4C55-8038-59823B7FF49F", "versionEndIncluding": "1.595v", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*", "matchCriteriaId": "AE537EF6-72AE-4091-AF6E-9959C3F45632", "versionEndIncluding": "1.063r", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iu_configuration_tool:*:*:*:*:*:*:*:*", "matchCriteriaId": "83B09E17-9CFF-4231-AE28-FB9D99332BCB", "versionEndIncluding": "1.04", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:iu_developer2:*:*:*:*:*:*:*:*", "matchCriteriaId": "D449D560-C64A-48B0-B1BB-31800FF3062E", "versionEndIncluding": "1.08", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_iq_appportal:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F2EA556-367B-4F32-99D2-C685742CCAEE", "versionEndIncluding": "1.17t", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*", "matchCriteriaId": "FF88C6B0-5641-488E-9AE2-6AF479EB10BF", "versionEndIncluding": "2.70y", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mi_configurator:*:*:*:*:*:*:*:*", "matchCriteriaId": "A661B972-912C-4DAA-9518-CC01E0EB1A81", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mr_configurator2:*:*:*:*:*:*:*:*", "matchCriteriaId": "50DAB8A0-E2F3-496A-B6B6-22E4243D104C", "versionEndIncluding": "1.110q", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*", "matchCriteriaId": "04FF09A2-B1C0-4A65-A420-22A044B7F2CD", "versionEndIncluding": "1.156n", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0C9B5B3-D4F6-4E00-89B4-964516BB989B", "versionEndIncluding": "4.20w", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:rt_toolbox3:*:*:*:*:*:*:*:*", "matchCriteriaId": "463E3740-A618-45A6-9C30-6FBC28077123", "versionEndIncluding": "1.70y", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BEAB1838-A2E2-4D12-A216-68DD9E4624CF", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g4:-:*:*:*:*:*:*:*", "matchCriteriaId": "B9B1BA74-5B02-400C-AA98-AFB29E848299", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E213C893-9C88-42C1-BE32-634D7BB84AD6", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g8:-:*:*:*:*:*:*:*", "matchCriteriaId": "8467C47A-2798-43FA-B132-A774B1148FC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g16_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "389EBE60-F4CF-4E82-975D-44DCBAC74929", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g16:-:*:*:*:*:*:*:*", "matchCriteriaId": "5F671BBC-41EE-41FF-87B1-36DBFA7A4BAD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g32_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2325BC60-32F9-46CA-8035-7E88360C15A1", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g32:-:*:*:*:*:*:*:*", "matchCriteriaId": "81DD3BFA-9E3A-4FAB-AB7B-6CC365628877", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78g64_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DC759E3E-6D0A-4BA5-AB2E-38947331C5B2", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78g64:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0A92E26-C302-4285-BED1-7B8637E252DA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D70552B7-C943-43B0-B5BD-ED43A853657E", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghv:-:*:*:*:*:*:*:*", "matchCriteriaId": "12E5533D-15A8-471B-899B-FE9F9655EE8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:mitsubishielectric:rd78ghw_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA2C0DCD-65E6-4B93-B92F-E4FE46CCA58C", "versionEndIncluding": "10", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:mitsubishielectric:rd78ghw:-:*:*:*:*:*:*:*", "matchCriteriaId": "8B5C3119-7579-4623-8513-65A281BDF0D1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code." }, { "lang": "es", "value": "diversos productos de Mitsubishi Electric Factory Automation presentan una vulnerabilidad que permite a un atacante ejecutar c\u00f3digo arbitrario" } ], "id": "CVE-2020-14523", "lastModified": "2024-11-21T05:03:27.300", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.6, "impactScore": 6.0, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-02-11T18:15:08.577", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU90224831/" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "https://jvn.jp/vu/JVNVU90224831/" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-212-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-008_en.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-22" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }