All the vulnerabilites related to siemens - ruggedcom_apr1808
Vulnerability from fkie_nvd
Published
2021-06-16 16:15
Modified
2024-11-21 05:21
Summary
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A8D4515-2E1D-4C69-B561-6F42B54FFD74",
              "versionEndExcluding": "5.34.44",
              "versionStartIncluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "38BBAD45-A06D-41D6-A1CC-5AD560E9DCB8",
              "versionEndExcluding": "5.25.44",
              "versionStartIncluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "816E66FC-0597-4442-9257-69B97D27D815",
              "versionEndExcluding": "5.16.25",
              "versionStartIncluding": "5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A889306B-C22C-4F29-BDBC-08B86252A584",
              "versionEndExcluding": "5.42.44",
              "versionStartIncluding": "5.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C47A7464-4682-474D-B094-CB6F2BD3B6B4",
              "versionEndExcluding": "5.35.25",
              "versionStartIncluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AECE476-8649-4928-9702-9E9737E1A764",
              "versionEndExcluding": "5.26.25",
              "versionStartIncluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C8173E6-4FED-481D-BF5E-3CABDF13CA61",
              "versionEndExcluding": "5.43.25",
              "versionStartIncluding": "5.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_apr1808_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08DFAD2-130C-4B75-B7EF-602C4B3324F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_apr1808:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD56E8B2-232B-4E1C-BB3F-41B0C1E31D7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75AE72A3-05C6-4564-81CC-67865D03D106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2ED11E5B-E60C-4359-B87C-E373DED77677",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1865061F-CF02-410B-B01B-2088F7104867",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68215EEF-243A-4B02-BEAB-C162A3564D60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62751FE8-48D7-4D7B-A7DD-4977DE539660",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EC3A82C-1380-4B21-BB17-3760A0B6A027",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2558478-44E0-4D42-A6DC-D4262D15A92A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AD30972-8CE2-46B4-A4B8-B209F6B616AC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFFA7953-DC4C-489A-B5A4-B832FAF3C143",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC414E9-5DBD-4D60-B0EA-6FB48207B628",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "193BF353-5D85-4F2E-94D0-329ED823FF07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8CE311F-98F9-4E58-9E52-BAFAF87C0819",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64538703-AE66-4D4A-B4A1-C88039B9543D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
    },
    {
      "lang": "es",
      "value": "En el kernel de Insyde InsydeH2O 5.x, algunos controladores SMM no validaban correctamente los par\u00e1metros CommBuffer y CommBufferSize, lo que permit\u00eda a los llamantes corromper el firmware o la memoria del sistema operativo. Las versiones corregidas para este problema en los controladores AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe y SdMcDeviceDxe son 05.16.25, 05.26.25, 05.35.25, 05.43.25 y 05.51.25 (para los n\u00facleos 5.1 a 5.5)"
    }
  ],
  "id": "CVE-2020-27339",
  "lastModified": "2024-11-21T05:21:01.897",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 6.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 0.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-06-16T16:15:07.897",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2021001"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2021001"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-10-01 03:15
Modified
2024-11-21 06:09
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A8D4515-2E1D-4C69-B561-6F42B54FFD74",
              "versionEndExcluding": "5.34.44",
              "versionStartIncluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "38BBAD45-A06D-41D6-A1CC-5AD560E9DCB8",
              "versionEndExcluding": "5.25.44",
              "versionStartIncluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "816E66FC-0597-4442-9257-69B97D27D815",
              "versionEndExcluding": "5.16.25",
              "versionStartIncluding": "5.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A889306B-C22C-4F29-BDBC-08B86252A584",
              "versionEndExcluding": "5.42.44",
              "versionStartIncluding": "5.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C47A7464-4682-474D-B094-CB6F2BD3B6B4",
              "versionEndExcluding": "5.35.25",
              "versionStartIncluding": "5.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AECE476-8649-4928-9702-9E9737E1A764",
              "versionEndExcluding": "5.26.25",
              "versionStartIncluding": "5.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:insyde:insydeh2o:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C8173E6-4FED-481D-BF5E-3CABDF13CA61",
              "versionEndExcluding": "5.43.25",
              "versionStartIncluding": "5.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_apr1808_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E08DFAD2-130C-4B75-B7EF-602C4B3324F0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_apr1808:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD56E8B2-232B-4E1C-BB3F-41B0C1E31D7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m5_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75AE72A3-05C6-4564-81CC-67865D03D106",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m5:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "506DEE00-30D2-4E29-9645-757EB8778C0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_field_pg_m6_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECC5341D-9982-4F18-9C8D-2912DDB8EF9A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_field_pg_m6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F3C3E60-7C36-4F5D-B454-97C9D0FD9459",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc127e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "846EE524-BC53-4DE5-81C5-6B5EB2DD8BEA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc127e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F63C0B17-60E2-4240-92FD-4B7C7D8F2C8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc227g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2ED11E5B-E60C-4359-B87C-E373DED77677",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc227g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D1E85AC-1305-4C5E-AD8B-39B2654F6057",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc277g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1865061F-CF02-410B-B01B-2088F7104867",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc277g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "320F5752-86B3-4C08-89D0-02272753A6D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc327g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68215EEF-243A-4B02-BEAB-C162A3564D60",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc327g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC7303D1-CC95-42C7-B843-C3B3B3336669",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc377g_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "62751FE8-48D7-4D7B-A7DD-4977DE539660",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc377g:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDD6F034-BC50-4223-AE5D-319F04C866A8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc427e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4EC3A82C-1380-4B21-BB17-3760A0B6A027",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc427e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A40D0CDB-7BE6-491F-B730-3B4E10CA159A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2558478-44E0-4D42-A6DC-D4262D15A92A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FDF9D4C3-1892-48FA-95B4-835B636A4005",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc477e_pro_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AD30972-8CE2-46B4-A4B8-B209F6B616AC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc477e_pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FC5CE20-7D08-4496-A857-C3A4BD0AB1AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc627e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFFA7953-DC4C-489A-B5A4-B832FAF3C143",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc627e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D9AF082-8345-4BE1-B1FC-6E0316BB833B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc647e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC414E9-5DBD-4D60-B0EA-6FB48207B628",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc647e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E430C4C5-D887-47C6-B50F-66EEE9519151",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc677e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "193BF353-5D85-4F2E-94D0-329ED823FF07",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc677e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F9FA42D-B2F0-456F-89B7-6A5789787FBA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_ipc847e_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8CE311F-98F9-4E58-9E52-BAFAF87C0819",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_ipc847e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1157418C-14C4-43C4-B63E-7E98D868A94F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_itp1000_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "64538703-AE66-4D4A-B4A1-C88039B9543D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_itp1000:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "187C6D51-5B86-484D-AE0F-26D1C9465580",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
    },
    {
      "lang": "es",
      "value": "Existe una vulnerabilidad en la rama SMM (System Management Mode) que registra un manejador SWSMI que no comprueba o valida suficientemente el puntero del buffer asignado (valores QWORD para CommBuffer). Esto puede ser utilizado por un atacante para corromper los datos en la memoria SMRAM e incluso llevar a la ejecuci\u00f3n de c\u00f3digo arbitrario"
    }
  ],
  "id": "CVE-2021-33626",
  "lastModified": "2024-11-21T06:09:13.410",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-10-01T03:15:06.593",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2021001"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.insyde.com/security-pledge/SA-2021001"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-829"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2020-27339
Vulnerability from cvelistv5
Published
2021-06-16 15:49
Modified
2024-08-04 16:11
Severity ?
Summary
In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:11:36.601Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge/SA-2021001"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T19:07:12",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2021001"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-27339",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In the kernel in Insyde InsydeH2O 5.x, certain SMM drivers did not correctly validate the CommBuffer and CommBufferSize parameters, allowing callers to corrupt either the firmware or the OS memory. The fixed versions for this issue in the AhciBusDxe, IdeBusDxe, NvmExpressDxe, SdHostDriverDxe, and SdMmcDeviceDxe drivers are 05.16.25, 05.26.25, 05.35.25, 05.43.25, and 05.51.25 (for Kernel 5.1 through 5.5)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.insyde.com/security-pledge/SA-2021001",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge/SA-2021001"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220216-0005/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220216-0005/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-27339",
    "datePublished": "2021-06-16T15:49:34",
    "dateReserved": "2020-10-20T00:00:00",
    "dateUpdated": "2024-08-04T16:11:36.601Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-33626
Vulnerability from cvelistv5
Published
2021-10-01 02:21
Modified
2024-08-03 23:58
Severity ?
Summary
A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:58:21.523Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.insyde.com/security-pledge/SA-2021001"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-22T19:07:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.insyde.com/security-pledge/SA-2021001"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-33626",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability exists in SMM (System Management Mode) branch that registers a SWSMI handler that does not sufficiently check or validate the allocated buffer pointer(QWORD values for CommBuffer). This can be used by an attacker to corrupt data in SMRAM memory and even lead to arbitrary code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.insyde.com/security-pledge",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "name": "https://www.insyde.com/security-pledge/SA-2021001",
              "refsource": "MISC",
              "url": "https://www.insyde.com/security-pledge/SA-2021001"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20220216-0006/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20220216-0006/"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ]
        },
        "source": {
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-33626",
    "datePublished": "2021-10-01T02:21:29",
    "dateReserved": "2021-05-28T00:00:00",
    "dateUpdated": "2024-08-03T23:58:21.523Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}