All the vulnerabilites related to siemens - scalance_s_firmware
Vulnerability from fkie_nvd
Published
2012-04-18 10:33
Modified
2024-11-21 01:37
Severity ?
Summary
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EACCA49-A75D-440B-BA66-95BCAD097A55",
              "versionEndIncluding": "2.3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_s_firmware:2.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E451FF6-96D0-4F3F-A1D3-DAC0D31B9180",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_s_firmware:2.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDC7B3EB-62BC-427A-AFF9-4A51378FA9B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s602:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBC68DCB-4A60-475F-92EC-8103EA916A48",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s612:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "66827C00-1929-4576-88DD-C146C15D7DB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s613:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6CCF33D-C441-42FB-9C97-7BFBE56BC00F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de b\u00fafer basado en pila en la implementaci\u00f3n del protocolo Profinet DCP en Siemens Scalance S Security Module firewall  S602 V2, S612 V2, S613 V2 con el firmware anterior a v2.3.0.3, permite a atacantes remotos causar una denegaci\u00f3n de servicio (interrupci\u00f3n del dispositivo) o ejecutar, posiblemente, c\u00f3digo arbitrario a trav\u00e9s de un marco de DCP manipulado."
    }
  ],
  "id": "CVE-2012-1800",
  "lastModified": "2024-11-21T01:37:48.413",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2012-04-18T10:33:34.933",
  "references": [
    {
      "source": "cret@cert.org",
      "url": "http://osvdb.org/81034"
    },
    {
      "source": "cret@cert.org",
      "url": "http://support.automation.siemens.com/WW/view/en/59869684"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://osvdb.org/81034"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://support.automation.siemens.com/WW/view/en/59869684"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2012-04-18 10:33
Modified
2024-11-21 01:37
Severity ?
Summary
The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EACCA49-A75D-440B-BA66-95BCAD097A55",
              "versionEndIncluding": "2.3.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_s_firmware:2.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E451FF6-96D0-4F3F-A1D3-DAC0D31B9180",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_s_firmware:2.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDC7B3EB-62BC-427A-AFF9-4A51378FA9B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s602:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBC68DCB-4A60-475F-92EC-8103EA916A48",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s612:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "66827C00-1929-4576-88DD-C146C15D7DB4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s613:v2:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6CCF33D-C441-42FB-9C97-7BFBE56BC00F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password."
    },
    {
      "lang": "es",
      "value": "Ell servidor web en el cortafuegos Siemens Scalance S Security Module S602 V2, S612 V2, and S613 V2 con el firmware anterior a v2.3.0.3 no limita la tasa de intentos de autenticaci\u00f3n, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos obtener acceso a trav\u00e9s de un ataque de fuerza bruta sobre la contrase\u00f1a administrativa."
    }
  ],
  "id": "CVE-2012-1799",
  "lastModified": "2024-11-21T01:37:48.300",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2012-04-18T10:33:34.887",
  "references": [
    {
      "source": "cret@cert.org",
      "url": "http://osvdb.org/81033"
    },
    {
      "source": "cret@cert.org",
      "url": "http://support.automation.siemens.com/WW/view/en/59869684"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://osvdb.org/81033"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://support.automation.siemens.com/WW/view/en/59869684"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-287"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2012-1799
Vulnerability from cvelistv5
Published
2012-04-18 10:00
Modified
2024-08-06 19:08
Severity ?
Summary
The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.518Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.automation.siemens.com/WW/view/en/59869684"
          },
          {
            "name": "81033",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://osvdb.org/81033"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-04-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-12-06T10:00:00",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/59869684"
        },
        {
          "name": "81033",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://osvdb.org/81033"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1799",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 does not limit the rate of authentication attempts, which makes it easier for remote attackers to obtain access via a brute-force attack on the administrative password."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.automation.siemens.com/WW/view/en/59869684",
              "refsource": "CONFIRM",
              "url": "http://support.automation.siemens.com/WW/view/en/59869684"
            },
            {
              "name": "81033",
              "refsource": "OSVDB",
              "url": "http://osvdb.org/81033"
            },
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1799",
    "datePublished": "2012-04-18T10:00:00",
    "dateReserved": "2012-03-21T00:00:00",
    "dateUpdated": "2024-08-06T19:08:38.518Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2012-1800
Vulnerability from cvelistv5
Published
2012-04-18 10:00
Modified
2024-08-06 19:08
Severity ?
Summary
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:08:38.674Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://support.automation.siemens.com/WW/view/en/59869684"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
          },
          {
            "name": "81034",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://osvdb.org/81034"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-04-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-11-20T10:00:00",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://support.automation.siemens.com/WW/view/en/59869684"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
        },
        {
          "name": "81034",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://osvdb.org/81034"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2012-1800",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://support.automation.siemens.com/WW/view/en/59869684",
              "refsource": "CONFIRM",
              "url": "http://support.automation.siemens.com/WW/view/en/59869684"
            },
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-268149.pdf"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-05.pdf"
            },
            {
              "name": "81034",
              "refsource": "OSVDB",
              "url": "http://osvdb.org/81034"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2012-1800",
    "datePublished": "2012-04-18T10:00:00",
    "dateReserved": "2012-03-21T00:00:00",
    "dateUpdated": "2024-08-06T19:08:38.674Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}