FKIE_CVE-2013-4651
Vulnerability from fkie_nvd - Published: 2013-08-01 13:32 - Updated: 2025-04-11 00:51
Severity ?
Summary
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w700_series_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80AFB6C8-3330-4E4B-840C-72AB3C25B005",
"versionEndIncluding": "4.4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w744-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0F42D479-A09D-467E-A078-56AC8964FF0A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w744-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AA38FD9E-6351-4799-9ED9-5C3613304B0D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w746-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BF4620B2-80DA-492E-A3C5-030728AA31E5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w746-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "73BF204A-FB9B-442B-973B-CFC7400AC88D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w747-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AF3D4CCA-26A3-4676-93C0-51C81C878E60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w747-1rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "972DB709-ECDB-4997-B580-68576C9BB068",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w784-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BF75780-5A9F-4D46-A057-1A39E06CBA9F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w784-1rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC7D8B71-AC38-4723-A87C-2EE4A3DEB827",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE3D27B5-CE66-4C4B-96F5-0F6F1E4AD6D5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-2pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9753A6CE-3792-4865-B506-FAD5F9E4F91B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-2rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D056894-E0D7-4086-BCBA-817ECB6DD806",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-3pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E76465BC-A22F-44C8-8474-1848EF0BCFA1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBFF410E-82DA-4B80-92A5-091970E969FB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-1rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3F5F0171-F7D9-4657-9CF9-C32CA4FA0902",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-2pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0AB8DD7E-9CA8-46C4-9CEB-6A5B4E8A8B21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-2rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17A32A22-8C02-47C3-9969-B730C9114691",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
},
{
"lang": "es",
"value": "Los dispositivos Siemens Scalance W7xx con firmware anterior a 4.5.4 utiliza el certificado X.509 embebido (hardcoded) para distintas instalaciones, lo que facilita a atacantes remotos llevar a cabo ataques man-in-the-middle contra las sesiones SSL aprovechando las relaciones de confianza del certificado."
}
],
"id": "CVE-2013-4651",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:N/C:P/I:P/A:C",
"version": "2.0"
},
"exploitabilityScore": 4.9,
"impactScore": 8.5,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-08-01T13:32:26.067",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-255"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2013-4652
Vulnerability from fkie_nvd - Published: 2013-08-01 13:32 - Updated: 2025-04-11 00:51
Severity ?
Summary
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:scalance_w700_series_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "80AFB6C8-3330-4E4B-840C-72AB3C25B005",
"versionEndIncluding": "4.4.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:scalance_w744-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0F42D479-A09D-467E-A078-56AC8964FF0A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w744-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AA38FD9E-6351-4799-9ED9-5C3613304B0D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w746-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BF4620B2-80DA-492E-A3C5-030728AA31E5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w746-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "73BF204A-FB9B-442B-973B-CFC7400AC88D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w747-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AF3D4CCA-26A3-4676-93C0-51C81C878E60",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w747-1rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "972DB709-ECDB-4997-B580-68576C9BB068",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w784-1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3BF75780-5A9F-4D46-A057-1A39E06CBA9F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w784-1rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BC7D8B71-AC38-4723-A87C-2EE4A3DEB827",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE3D27B5-CE66-4C4B-96F5-0F6F1E4AD6D5",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-2pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9753A6CE-3792-4865-B506-FAD5F9E4F91B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-2rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0D056894-E0D7-4086-BCBA-817ECB6DD806",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w786-3pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E76465BC-A22F-44C8-8474-1848EF0BCFA1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-1pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FBFF410E-82DA-4B80-92A5-091970E969FB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-1rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3F5F0171-F7D9-4657-9CF9-C32CA4FA0902",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-2pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "0AB8DD7E-9CA8-46C4-9CEB-6A5B4E8A8B21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:h:siemens:scalance_w788-2rr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "17A32A22-8C02-47C3-9969-B730C9114691",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
},
{
"lang": "es",
"value": "Vulnerabilidad sin especificar en el interfaz de gesti\u00f3n de los dispositivos Siemens Scalance W7xx con firmware anterior a 4.5.4, permite a atacantes remotos evitar la autenticaci\u00f3n y ejecutar c\u00f3digo arbitrario a trav\u00e9s de conexiones (1)SSH o (2)Telnet."
}
],
"id": "CVE-2013-4652",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2013-08-01T13:32:26.093",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2013-4652 (GCVE-0-2013-4652)
Vulnerability from cvelistv5 – Published: 2013-07-31 18:00 – Updated: 2024-09-16 22:26
VLAI?
Summary
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.124Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4652",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4652",
"datePublished": "2013-07-31T18:00:00Z",
"dateReserved": "2013-06-24T00:00:00Z",
"dateUpdated": "2024-09-16T22:26:37.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4651 (GCVE-0-2013-4651)
Vulnerability from cvelistv5 – Published: 2013-07-31 18:00 – Updated: 2024-09-17 03:32
VLAI?
Summary
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:26.502Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4651",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4651",
"datePublished": "2013-07-31T18:00:00Z",
"dateReserved": "2013-06-24T00:00:00Z",
"dateUpdated": "2024-09-17T03:32:39.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4652 (GCVE-0-2013-4652)
Vulnerability from nvd – Published: 2013-07-31 18:00 – Updated: 2024-09-16 22:26
VLAI?
Summary
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.124Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4652",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4652",
"datePublished": "2013-07-31T18:00:00Z",
"dateReserved": "2013-06-24T00:00:00Z",
"dateUpdated": "2024-09-16T22:26:37.770Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4651 (GCVE-0-2013-4651)
Vulnerability from nvd – Published: 2013-07-31 18:00 – Updated: 2024-09-17 03:32
VLAI?
Summary
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:26.502Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T18:00:00Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4651",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers\u0027 installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate\u0027s trust relationship."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-120908.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4651",
"datePublished": "2013-07-31T18:00:00Z",
"dateReserved": "2013-06-24T00:00:00Z",
"dateUpdated": "2024-09-17T03:32:39.448Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}