All the vulnerabilites related to siemens - scalance_x-300poe
Vulnerability from fkie_nvd
Published
2015-01-21 17:59
Modified
2024-11-21 02:19
Severity ?
Summary
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-408_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9B53C2F-04E1-4EE7-A052-2F141179DB8E",
              "versionEndIncluding": "3.9.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-408:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED518CFA-AFD5-4ACA-ACFD-C7E527EC4E04",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_series_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75396A33-A4A6-46D9-A6CF-11BB86221B60",
              "versionEndIncluding": "3.9.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2F32466-A411-4D69-864A-4434D3D5DB54",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBE436EC-0C06-4635-BF0A-24A01A3C94C5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets."
    },
    {
      "lang": "es",
      "value": "El servidor FTP Siemens en los switches SCALANCE X-300 con firmware anterior a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a usuarios remotos autenticados causar una denegaci\u00f3n de servicio (reinicio) a trav\u00e9s de paquetes FTP modificados."
    }
  ],
  "id": "CVE-2014-8479",
  "lastModified": "2024-11-21T02:19:08.900",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2015-01-21T17:59:01.323",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2015-01-21 17:59
Modified
2024-11-21 02:19
Severity ?
Summary
The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_series_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75396A33-A4A6-46D9-A6CF-11BB86221B60",
              "versionEndIncluding": "3.9.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2F32466-A411-4D69-864A-4434D3D5DB54",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FBE436EC-0C06-4635-BF0A-24A01A3C94C5",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-408_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9B53C2F-04E1-4EE7-A052-2F141179DB8E",
              "versionEndIncluding": "3.9.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-408:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED518CFA-AFD5-4ACA-ACFD-C7E527EC4E04",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests."
    },
    {
      "lang": "es",
      "value": "El servidor web en los switches SCALANCE X-300 con firmware anteriores a 4.0 y los switches SCALANCE X 408 con firmware anterior a 4.0 permite a atacantes remotos causar una denegaci\u00f3n de servicio (reinicio) a trav\u00e9s de peticiones HTTP mal formadas."
    }
  ],
  "id": "CVE-2014-8478",
  "lastModified": "2024-11-21T02:19:08.760",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2015-01-21T17:59:00.060",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2014-8479
Vulnerability from cvelistv5
Published
2015-01-21 17:00
Modified
2024-08-06 13:18
Severity ?
Summary
The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.283Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-01-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T14:06:13",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8479",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8479",
    "datePublished": "2015-01-21T17:00:00",
    "dateReserved": "2014-10-24T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2014-8478
Vulnerability from cvelistv5
Published
2015-01-21 17:00
Modified
2024-08-06 13:18
Severity ?
Summary
The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:18:48.325Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-01-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T14:06:14",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2014-8478",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-321046.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-321046.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2014-8478",
    "datePublished": "2015-01-21T17:00:00",
    "dateReserved": "2014-10-24T00:00:00",
    "dateUpdated": "2024-08-06T13:18:48.325Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}