Vulnerabilites related to siemens - scalance_x-414-3e_firmware
Vulnerability from fkie_nvd
Published
2019-06-12 14:29
Modified
2024-11-21 04:46
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf | Patch, Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | scalance_x-200_firmware | * | |
siemens | scalance_x-200 | - | |
siemens | scalance_x-200irt_firmware | * | |
siemens | scalance_x-200irt | - | |
siemens | scalance_x-300_firmware | * | |
siemens | scalance_x-300 | - | |
siemens | scalance_x-414-3e_firmware | * | |
siemens | scalance_x-414-3e | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "443B5E7B-A491-4883-9853-A88D3B24E220", "versionEndExcluding": "5.2.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "6FEF9F9F-4066-483B-BF95-3BA5625284DF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "602CAF2E-2276-455C-82E5-A05BBFC198C5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "94C7BE35-D3A6-488C-BB3D-D17D65DF4B80", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3F2C50BB-CC63-40BE-A5F0-0F0C342586CA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x-414-3e_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9B3E06E-8822-406C-907A-40AE328B311C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x-414-3e:-:*:*:*:*:*:*:*", "matchCriteriaId": "CE7762EE-1253-4A4B-81CF-1A6423135AB6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.2.4), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.5.0), familia de switches SCALANCE X-300 (incluyendo X408 y las variantes SIPLUS NET) (Todas las versiones anteriores a V4.1.3), SCALANCE X-414-3E (Todas las versiones). Los dispositivos afectados almacenan contrase\u00f1as en un formato recuperable. Un atacante puede extraer y recuperar contrase\u00f1as de dispositivos desde la configuraci\u00f3n del dispositivo. La explotaci\u00f3n exitosa requiere acceso a una copia de seguridad de la configuraci\u00f3n del dispositivo e impacta la confidencialidad de las contrase\u00f1as almacenadas. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda la explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad" } ], "id": "CVE-2019-6567", "lastModified": "2024-11-21T04:46:42.633", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "LOW", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 2.1, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-06-12T14:29:04.820", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-257" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-522" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2019-6567
Vulnerability from cvelistv5
Published
2019-06-12 13:47
Modified
2024-08-04 20:23
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SCALANCE X-200 switch family (incl. SIPLUS NET variants) |
Version: All Versions < V5.2.4 |
||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T20:23:22.108Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.2.4" } ] }, { "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.5.0" } ] }, { "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.3" } ] }, { "product": "SCALANCE X-414-3E", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-257", "description": "CWE-257: Storing Passwords in a Recoverable Format", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-02-09T15:38:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-6567", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All Versions \u003c V5.2.4" } ] } }, { "product_name": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V5.5.0" } ] } }, { "product_name": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V4.1.3" } ] } }, { "product_name": "SCALANCE X-414-3E", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions \u003c V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-257: Storing Passwords in a Recoverable Format" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-6567", "datePublished": "2019-06-12T13:47:56", "dateReserved": "2019-01-22T00:00:00", "dateUpdated": "2024-08-04T20:23:22.108Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }