Vulnerabilites related to siemens - scalance_xc216-4c_g_\(e\/ip\)
CVE-2022-36324 (GCVE-0-2022-36324)
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: All versions < V7.1.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M804PB Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE S615 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XP208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-03T10:00:04.354Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM RM1224 LTE(4G) EU",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM RM1224 LTE(4G) NAM",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M804PB",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M812-1 ADSL-Router (Annex A)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M812-1 ADSL-Router (Annex B)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M816-1 ADSL-Router (Annex A)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M816-1 ADSL-Router (Annex B)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M826-2 SHDSL-Router",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M874-2",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M874-3",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-3 (EVDO)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-3 (ROK)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-4 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-4 (NAM)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM853-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM856-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM856-1 (RoW)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE S615",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC622-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC626-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC632-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC636-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC642-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC646-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2 EEC M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2IA M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W721-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W721-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45 (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W738-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W738-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W761-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W761-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45 (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12 EEC (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2IA RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2IA RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 EEC (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 EEC (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM766-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM766-1 (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3LD (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3LD (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB208 (E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB208 (PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (ST, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3LD (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3LD (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB216 (E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB216 (PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2 (SC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2 (ST/BFOC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE EEC (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G (EIP DEF.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G (EIP def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-3G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-3G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G (EIP Def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G (EIP Def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204 DNA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204-2BA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204-2BA DNA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-4C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-8C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-8C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM416-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM416-4C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208 (Ethernet/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208PoE EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216 (Ethernet/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216POE EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR324WG (24 x FE, AC 230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR324WG (24 X FE, DC 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR326-2C PoE WG",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR326-2C PoE WG (without UL)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (28xGE, AC 230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (28xGE, DC 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 1x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 1x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 24V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 24V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 2x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 2x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 1x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 1x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 24V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 24V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 2x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 2x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (2HR2, L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2, L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC206-2",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC206-2SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC216-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.5,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-770",
                     description: "CWE-770: Allocation of Resources Without Limits or Throttling",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-10-10T10:21:02.321Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2022-36324",
      datePublished: "2022-08-10T11:18:39",
      dateReserved: "2022-07-20T00:00:00",
      dateUpdated: "2024-08-03T10:00:04.354Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

CVE-2020-28391 (GCVE-0-2020-28391)
Vulnerability from cvelistv5
Published
2021-01-12 00:00
Modified
2024-08-04 16:33
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-04T16:33:59.106Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf",
               },
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.2.5",
                  },
               ],
            },
            {
               product: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.5.0",
                  },
               ],
            },
            {
               product: "SCALANCE X-200RNA switch family",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V3.2.7",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-321",
                     description: "CWE-321: Use of Hard-coded Cryptographic Key",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2022-12-13T00:00:00",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf",
            },
            {
               url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2020-28391",
      datePublished: "2021-01-12T00:00:00",
      dateReserved: "2020-11-10T00:00:00",
      dateUpdated: "2024-08-04T16:33:59.106Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

CVE-2020-15800 (GCVE-0-2020-15800)
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 13:30
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-04T13:30:21.877Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.2.5",
                  },
               ],
            },
            {
               product: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.5.0",
                  },
               ],
            },
            {
               product: "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.1.0",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-122",
                     description: "CWE-122: Heap-based Buffer Overflow",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2021-09-14T10:47:09",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               tags: [
                  "x_refsource_MISC",
               ],
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "productcert@siemens.com",
               ID: "CVE-2020-15800",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V5.2.5",
                                       },
                                    ],
                                 },
                              },
                              {
                                 product_name: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V5.5.0",
                                       },
                                    ],
                                 },
                              },
                              {
                                 product_name: "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V4.1.0",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "Siemens",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "CWE-122: Heap-based Buffer Overflow",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
                     refsource: "MISC",
                     url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2020-15800",
      datePublished: "2021-01-12T20:18:33",
      dateReserved: "2020-07-15T00:00:00",
      dateUpdated: "2024-08-04T13:30:21.877Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

CVE-2022-36323 (GCVE-0-2022-36323)
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: All versions < V7.1.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M804PB Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE S615 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XP208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-03T10:00:04.366Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM RM1224 LTE(4G) EU",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM RM1224 LTE(4G) NAM",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M804PB",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M812-1 ADSL-Router (Annex A)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M812-1 ADSL-Router (Annex B)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M816-1 ADSL-Router (Annex A)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M816-1 ADSL-Router (Annex B)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M826-2 SHDSL-Router",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M874-2",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M874-3",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-3 (EVDO)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-3 (ROK)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-4 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-4 (NAM)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM853-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM856-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM856-1 (RoW)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE S615",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC622-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC626-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC632-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC636-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC642-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC646-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2 EEC M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2IA M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W721-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W721-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45 (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W738-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W738-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W761-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W761-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45 (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12 EEC (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2IA RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2IA RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 EEC (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 EEC (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM766-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM766-1 (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3LD (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3LD (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB208 (E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB208 (PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (ST, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3LD (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3LD (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB216 (E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB216 (PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2 (SC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2 (ST/BFOC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE EEC (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G (EIP DEF.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G (EIP def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-3G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-3G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G (EIP Def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G (EIP Def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204 DNA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204-2BA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204-2BA DNA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-4C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-8C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-8C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM416-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM416-4C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208 (Ethernet/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208PoE EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216 (Ethernet/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216POE EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR324WG (24 x FE, AC 230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR324WG (24 X FE, DC 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR326-2C PoE WG",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR326-2C PoE WG (without UL)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (28xGE, AC 230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (28xGE, DC 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 1x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 1x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 24V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 24V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 2x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 2x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 1x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 1x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 24V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 24V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 2x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 2x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (2HR2, L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2, L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC206-2",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC206-2SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC216-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 9.1,
                  baseSeverity: "CRITICAL",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-74",
                     description: "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-10-10T10:20:59.701Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2022-36323",
      datePublished: "2022-08-10T11:18:33",
      dateReserved: "2022-07-20T00:00:00",
      dateUpdated: "2024-08-03T10:00:04.366Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

CVE-2020-15799 (GCVE-0-2020-15799)
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 13:30
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-04T13:30:21.812Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.2.5",
                  },
               ],
            },
            {
               product: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.5.0",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-306",
                     description: "CWE-306: Missing Authentication for Critical Function",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2021-09-14T10:47:08",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               tags: [
                  "x_refsource_MISC",
               ],
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "productcert@siemens.com",
               ID: "CVE-2020-15799",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V5.2.5",
                                       },
                                    ],
                                 },
                              },
                              {
                                 product_name: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V5.5.0",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "Siemens",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "CWE-306: Missing Authentication for Critical Function",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
                     refsource: "MISC",
                     url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2020-15799",
      datePublished: "2021-01-12T20:18:33",
      dateReserved: "2020-07-15T00:00:00",
      dateUpdated: "2024-08-04T13:30:21.812Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

CVE-2020-25226 (GCVE-0-2020-25226)
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 15:33
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-04T15:33:04.885Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.2.5",
                  },
               ],
            },
            {
               product: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V5.5.0",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-122",
                     description: "CWE-122: Heap-based Buffer Overflow",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2021-09-14T10:47:10",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               tags: [
                  "x_refsource_MISC",
               ],
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "productcert@siemens.com",
               ID: "CVE-2020-25226",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V5.2.5",
                                       },
                                    ],
                                 },
                              },
                              {
                                 product_name: "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V5.5.0",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "Siemens",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "CWE-122: Heap-based Buffer Overflow",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
                     refsource: "MISC",
                     url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2020-25226",
      datePublished: "2021-01-12T20:18:33",
      dateReserved: "2020-09-10T00:00:00",
      dateUpdated: "2024-08-04T15:33:04.885Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

CVE-2022-36325 (GCVE-0-2022-36325)
Vulnerability from cvelistv5
Published
2022-08-10 11:18
Modified
2024-08-03 10:00
Summary
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Impacted products
Vendor Product Version
Siemens RUGGEDCOM RM1224 LTE(4G) EU Version: All versions < V7.1.2
Create a notification for this product.
   Siemens RUGGEDCOM RM1224 LTE(4G) NAM Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M804PB Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M812-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router (Annex A) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M816-1 ADSL-Router (Annex B) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M826-2 SHDSL-Router Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M874-2 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M874-3 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (EVDO) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-3 (ROK) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE M876-4 (NAM) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM853-1 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (EU) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE MUM856-1 (RoW) Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE S615 Version: All versions < V7.1.2
Create a notification for this product.
   Siemens SCALANCE SC622-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC626-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC632-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC636-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC642-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE SC646-2C Version: All versions < V2.3.1
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2 EEC M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W1788-2IA M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W721-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W722-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W734-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W738-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W748-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W761-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W774-1 RJ45 (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W778-1 M12 EEC (USA) Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2 SFP Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W786-2IA RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-1 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 M12 EEC Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE W788-2 RJ45 Version: All versions
Create a notification for this product.
   Siemens SCALANCE WAM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WAM766-1 EEC (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM763-1 Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (EU) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE WUM766-1 (US) Version: All versions < V2.0
Create a notification for this product.
   Siemens SCALANCE XB205-3 (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3 (ST, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB205-3LD (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB208 (PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3 (ST, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB213-3LD (SC, PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (E/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XB216 (PN) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (SC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2 (ST/BFOC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2G PoE EEC (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G (EIP DEF.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC206-2SFP G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G (EIP def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC208G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-3G PoE (54 V DC) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G (EIP Def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216-4C G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC216EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G (EIP Def.) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XC224-4C G EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204 DNA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XF204-2BA DNA Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XM408-4C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-4C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM408-8C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XM416-4C (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XP208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208 (Ethernet/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP208PoE EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216 (Ethernet/IP) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XP216POE EEC Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 x FE, AC 230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR324WG (24 X FE, DC 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR326-2C PoE WG (without UL) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) Version: All versions < V4.4
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 1x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 24V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR524-8C, 2x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 1x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 24V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR526-8C, 2x230V (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2, L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR528-6M (L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2, L3 int.) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SCALANCE XR552-12M (2HR2) Version: All versions < V6.6
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2 Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC206-2SFP Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC208 Version: All versions < V4.4
Create a notification for this product.
   Siemens SIPLUS NET SCALANCE XC216-4C Version: All versions < V4.4
Create a notification for this product.
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-03T10:00:04.293Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM RM1224 LTE(4G) EU",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "RUGGEDCOM RM1224 LTE(4G) NAM",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M804PB",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M812-1 ADSL-Router (Annex A)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M812-1 ADSL-Router (Annex B)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M816-1 ADSL-Router (Annex A)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M816-1 ADSL-Router (Annex B)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M826-2 SHDSL-Router",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M874-2",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M874-3",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-3 (EVDO)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-3 (ROK)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-4 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE M876-4 (NAM)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM853-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM856-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE MUM856-1 (RoW)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE S615",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V7.1.2",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC622-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC626-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC632-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC636-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC642-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE SC646-2C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.3.1",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2 EEC M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W1788-2IA M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W721-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W721-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W722-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W734-1 RJ45 (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W738-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W738-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W748-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W761-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W761-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W774-1 RJ45 (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W778-1 M12 EEC (USA)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2 SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2IA RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W786-2IA RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-1 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 M12 EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE W788-2 RJ45",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 EEC (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WAM766-1 EEC (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM763-1",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM766-1 (EU)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE WUM766-1 (US)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V2.0",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3 (ST, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3LD (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB205-3LD (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB208 (E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB208 (PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (ST, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3 (ST, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3LD (SC, E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB213-3LD (SC, PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB216 (E/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XB216 (PN)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2 (SC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2 (ST/BFOC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2G PoE EEC (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G (EIP DEF.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC206-2SFP G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G (EIP def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC208G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-3G PoE",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-3G PoE (54 V DC)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G (EIP Def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216-4C G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC216EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G (EIP Def.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XC224-4C G EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204 DNA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204-2BA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XF204-2BA DNA",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-4C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-8C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM408-8C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM416-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XM416-4C (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208 (Ethernet/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP208PoE EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216 (Ethernet/IP)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XP216POE EEC",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR324WG (24 x FE, AC 230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR324WG (24 X FE, DC 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR326-2C PoE WG",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR326-2C PoE WG (without UL)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (28xGE, AC 230V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR328-4C WG (28xGE, DC 24V)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 1x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 1x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 24V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 24V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 2x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR524-8C, 2x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 1x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 1x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 24V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 24V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 2x230V",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR526-8C, 2x230V (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (2HR2, L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR528-6M (L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2, L3 int.)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SCALANCE XR552-12M (2HR2)",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V6.6",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC206-2",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC206-2SFP",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC208",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "SIPLUS NET SCALANCE XC216-4C",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V4.4",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 6.8,
                  baseSeverity: "MEDIUM",
                  vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
                  version: "3.1",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-80",
                     description: "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2023-10-10T10:21:04.880Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2022-36325",
      datePublished: "2022-08-10T11:18:45",
      dateReserved: "2022-07-20T00:00:00",
      dateUpdated: "2024-08-03T10:00:04.293Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

Vulnerability from fkie_nvd
Published
2021-01-12 21:15
Modified
2024-11-21 05:17
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.
Impacted products
Vendor Product Version
siemens scalance_x200-4pirt_firmware *
siemens scalance_x200-4pirt -
siemens scalance_x201-3pirt_firmware *
siemens scalance_x201-3pirt -
siemens scalance_x202-2irt_firmware *
siemens scalance_x202-2irt -
siemens scalance_x202-2pirt_firmware *
siemens scalance_x202-2pirt -
siemens scalance_x202-2pirt_siplus_net_firmware *
siemens scalance_x202-2pirt_siplus_net -
siemens scalance_x204irt_firmware *
siemens scalance_x204irt -
siemens scalance_x307-3_firmware *
siemens scalance_x307-3 -
siemens scalance_x307-3ld_firmware *
siemens scalance_x307-3ld -
siemens scalance_x308-2_firmware *
siemens scalance_x308-2 -
siemens scalance_x308-2ld_firmware *
siemens scalance_x308-2ld -
siemens scalance_x308-2lh_firmware *
siemens scalance_x308-2lh -
siemens scalance_x308-2lh\+_firmware *
siemens scalance_x308-2lh\+ -
siemens scalance_x308-2m_firmware *
siemens scalance_x308-2m -
siemens scalance_x308-2m_ts_firmware *
siemens scalance_x308-2m_ts -
siemens scalance_x310_firmware *
siemens scalance_x310 -
siemens scalance_x310fe_firmware *
siemens scalance_x310fe -
siemens scalance_x320-1fe_firmware *
siemens scalance_x320-1fe -
siemens scalance_x320-3ldfe_firmware *
siemens scalance_x320-3ldfe -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware *
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xf201-3p_irt_firmware *
siemens scalance_xf201-3p_irt -
siemens scalance_xf202-2p_irt_firmware *
siemens scalance_xf202-2p_irt -
siemens scalance_xf204_firmware *
siemens scalance_xf204 -
siemens scalance_xf204-2_firmware *
siemens scalance_xf204-2 -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xf204_dna_firmware *
siemens scalance_xf204_dna -
siemens scalance_xf204irt_firmware *
siemens scalance_xf204irt -
siemens scalance_xf206-1_firmware *
siemens scalance_xf206-1 -
siemens scalance_xf208_firmware *
siemens scalance_xf208 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "43B261ED-08C4-4A0D-8BAC-221006AB6F93",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FDCB432-1AD0-4BF1-839F-8091D9871831",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "53F56390-77CB-42D5-A603-5FB29EE5DAA5",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "47498977-D642-4864-BB94-4CE077EDEB82",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "666FACCE-89EB-4E5D-A718-F1D4945F7DF4",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A8B1D979-038F-42F4-AB7D-E0664D051B4E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B79AD48F-2B99-4BE5-B3D7-440E2D3BC699",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7819B14-7E93-4D0F-AAD5-049BE3B36D07",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CD18B3BE-E98D-46D1-AA10-89EB89BAFFEB",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DABC3436-E04E-4B6C-9EF4-47B08C57B166",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C94D093-9D17-47C9-A7F6-28FF241BF874",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9676DB10-982D-445F-9779-B39AE720AF2F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "48D3EB09-6069-4289-A61E-C15B044EA2E2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7737F0C2-43FC-4330-88F2-9B08BA5B35D7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "40A1A5F9-4971-4E9D-BBE7-5A0357C56213",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FE1909FA-C8C6-46BE-83C6-2635D36FE69B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F53C74B-2154-417E-ACFE-01F0BACD3F15",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6DDBD94D-5312-4A54-AF76-D9DF791C0292",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D76A2268-5397-466C-98B5-01B46B4840A1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "85153EED-C677-495D-A6BB-72365DE1ED3F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2F8888A7-3285-4ACA-A5AD-2B0578050C4C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC54911E-C432-48FA-9551-9644422FFE14",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A2C12934-E79C-41A4-B023-BADD7D68CB55",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFCCB68C-A58D-4543-A11F-721B01FFBBA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D288227C-69C1-4248-AB4A-51F44A41FDEA",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FE3716E-1C0A-4B72-809A-8318E5853FB1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FB34E83-83A3-45C3-B040-D8910971D439",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "91EDD23A-1DBD-4117-9396-89ADBC705B3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC54880F-CBF4-4772-A4FB-B07D97287D44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AF07B014-1BA3-477E-A405-5DB35F68126A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "80502856-7617-4ED9-A103-681021131EE0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7178F049-8E48-4175-AE8C-818128205D33",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7327CDF-EF0D-443B-A822-D69669C3B80C",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C7DDB0D1-21AC-43AC-9DDF-C6D89D3F1AA1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FAB9D2E-94BC-4C90-ADF3-27FB34FC23A9",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3003D9C7-A979-4289-AADD-190A55434F31",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1A0E6F26-15BE-4586-8ACD-1DAF9492A7D7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED3A29A7-F1B0-4A2C-AB63-6E4A57A6864D",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4EFEB827-71F1-4DDF-B156-949AF8E39A34",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1B191270-07F7-4173-833A-7F4929F643BF",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC590D4F-C818-4CD8-A8E9-E2A951E5D768",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "804E37AB-9EE4-4931-A874-4FBD427252D1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6AABE919-D289-43CB-A285-3212E630B313",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CA08C94B-BE44-49D1-AB10-7512F65D6DF1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "578CE1DA-BA53-4EA5-AB2D-4670321DDF81",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFEA3FDE-9575-4E9B-BE5F-6BEB005381D8",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "5FC77B9E-9081-44E0-82AF-0411940B0684",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED6AD6D3-75AC-4C7E-9471-8288FB7AABA4",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D51DCE8E-2E29-4969-A26B-A1A10220CA83",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F4F3FB17-F6E8-4BB1-B910-C9F03B936C32",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DF97E576-EBD2-4F1F-BE8F-4254D134565B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0378595B-379F-4775-B5D9-CCAC4042F635",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8A03BBB2-9650-4C8A-A137-0C8AC6CDAD66",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BCD1CF2-F24A-4C47-9C88-340E67C77871",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4DAD438B-DABE-4B9A-9CDB-9BAC16313F0F",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E1F3FE19-E279-4280-8F67-0C085B083E10",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED7BCCB2-CE77-45A3-A6E1-D591894847C7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7C43419-B7AA-40EB-A40D-840F975BE2EC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "580A5BD5-2E8E-4801-BFE8-7476088F4214",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FFAC6598-DDAC-4873-9545-39B0EF21D478",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "561064E3-FC05-4028-B75D-4D2519FEFD24",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4303ED83-6610-458F-BEE9-B99BA31DD962",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "475E5069-C120-4D49-AB9D-D3C3F94BD093",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "41614C70-97B4-44C8-A441-530A413A26F9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "274E5C49-CA32-44D2-A864-C99A48CAA869",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6751FB7D-C72C-4321-B535-5880FE696FC3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CD13707-1164-415E-9083-7946D151F1FC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0F1AE867-67B4-4871-BF56-88017533A737",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3A09FF2D-F369-47B5-AEE4-A862BEDD9851",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "69285324-4C0B-4BDC-B60D-F653679DD52D",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0BBC3005-41D0-4BA0-A146-E48E612CAF58",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "85B917B7-81E1-4419-B493-1D321027017E",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FCBEE10A-7E96-4239-AE6C-5FA9A6A32196",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "42288C48-A2AA-4AA1-B5A2-F83C5A3689AE",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "57E5489B-277A-4D02-B4AB-4DB65969EED2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFCDC84E-0695-409A-844B-D24024CC33F2",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B40D2EB-5C69-47FA-801B-DC48407D418C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1DB6C03-71BF-4359-834B-384E78910E64",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8082D4C1-C59E-43B6-B11F-C814ACD00321",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34349AEF-170F-432F-8D64-347F08536D3A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EACF7493-4FE6-4902-9EE7-76F1B4AB118A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3237051D-0342-4DB8-B4A1-40A3B33A67BB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4969C410-25DF-4BFA-9125-53D63B33691B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B4A2ED6E-6632-4DD9-A359-73EB28BB306B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3B54DF8C-BB5A-46AF-862D-DC8E984A05AB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF74FFD-81C8-4E63-8B7B-AEBD98AB34F7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The web server of the affected devices contains a vulnerability that may lead to a buffer overflow condition. An attacker could cause this condition on the webserver by sending a specially crafted request. The webserver could stop and not recover anymore.",
      },
      {
         lang: "es",
         value: "Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluyendo Variantes SIPLUS NET) (Todas las versiones anteriores a la versiónV5.2.5), familia de switches SCALANCE X-200IRT (incluyendo Variantes SIPLUS NET) (Todas las versiones anteriores a la versiónV5.5.0). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conllevar una condición de desbordamiento del búfer. Un atacante podría causar esta condición en el servidor web enviando una petición especialmente diseñada. El servidor web podría detenerse y no recuperarse más",
      },
   ],
   id: "CVE-2020-25226",
   lastModified: "2024-11-21T05:17:42.257",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "LOW",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "COMPLETE",
               baseScore: 10,
               confidentialityImpact: "COMPLETE",
               integrityImpact: "COMPLETE",
               vectorString: "AV:N/AC:L/Au:N/C:C/I:C/A:C",
               version: "2.0",
            },
            exploitabilityScore: 10,
            impactScore: 10,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2021-01-12T21:15:16.543",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-122",
            },
         ],
         source: "productcert@siemens.com",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-787",
            },
         ],
         source: "nvd@nist.gov",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2021-01-12 21:15
Modified
2024-11-21 05:22
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Impacted products
Vendor Product Version
siemens scalance_x200-4pirt_firmware *
siemens scalance_x200-4pirt -
siemens scalance_x201-3pirt_firmware *
siemens scalance_x201-3pirt -
siemens scalance_x202-2irt_firmware *
siemens scalance_x202-2irt -
siemens scalance_x202-2pirt_firmware *
siemens scalance_x202-2pirt -
siemens scalance_x202-2pirt_siplus_net_firmware *
siemens scalance_x202-2pirt_siplus_net -
siemens scalance_x204irt_firmware *
siemens scalance_x204irt -
siemens scalance_x307-3_firmware *
siemens scalance_x307-3 -
siemens scalance_x307-3ld_firmware *
siemens scalance_x307-3ld -
siemens scalance_x308-2_firmware *
siemens scalance_x308-2 -
siemens scalance_x308-2ld_firmware *
siemens scalance_x308-2ld -
siemens scalance_x308-2lh_firmware *
siemens scalance_x308-2lh -
siemens scalance_x308-2lh\+_firmware *
siemens scalance_x308-2lh\+ -
siemens scalance_x308-2m_firmware *
siemens scalance_x308-2m -
siemens scalance_x308-2m_ts_firmware *
siemens scalance_x308-2m_ts -
siemens scalance_x310_firmware *
siemens scalance_x310 -
siemens scalance_x310fe_firmware *
siemens scalance_x310fe -
siemens scalance_x320-1fe_firmware *
siemens scalance_x320-1fe -
siemens scalance_x320-3ldfe_firmware *
siemens scalance_x320-3ldfe -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware *
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xf201-3p_irt_firmware *
siemens scalance_xf201-3p_irt -
siemens scalance_xf202-2p_irt_firmware *
siemens scalance_xf202-2p_irt -
siemens scalance_xf204_firmware *
siemens scalance_xf204 -
siemens scalance_xf204-2_firmware *
siemens scalance_xf204-2 -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xf204_dna_firmware *
siemens scalance_xf204_dna -
siemens scalance_xf204irt_firmware *
siemens scalance_xf204irt -
siemens scalance_xf206-1_firmware *
siemens scalance_xf206-1 -
siemens scalance_xf208_firmware *
siemens scalance_xf208 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "43B261ED-08C4-4A0D-8BAC-221006AB6F93",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FDCB432-1AD0-4BF1-839F-8091D9871831",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "53F56390-77CB-42D5-A603-5FB29EE5DAA5",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "47498977-D642-4864-BB94-4CE077EDEB82",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "666FACCE-89EB-4E5D-A718-F1D4945F7DF4",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A8B1D979-038F-42F4-AB7D-E0664D051B4E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B79AD48F-2B99-4BE5-B3D7-440E2D3BC699",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7819B14-7E93-4D0F-AAD5-049BE3B36D07",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CD18B3BE-E98D-46D1-AA10-89EB89BAFFEB",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DABC3436-E04E-4B6C-9EF4-47B08C57B166",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C94D093-9D17-47C9-A7F6-28FF241BF874",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9676DB10-982D-445F-9779-B39AE720AF2F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "48D3EB09-6069-4289-A61E-C15B044EA2E2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7737F0C2-43FC-4330-88F2-9B08BA5B35D7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "40A1A5F9-4971-4E9D-BBE7-5A0357C56213",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FE1909FA-C8C6-46BE-83C6-2635D36FE69B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F53C74B-2154-417E-ACFE-01F0BACD3F15",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6DDBD94D-5312-4A54-AF76-D9DF791C0292",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D76A2268-5397-466C-98B5-01B46B4840A1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "85153EED-C677-495D-A6BB-72365DE1ED3F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2F8888A7-3285-4ACA-A5AD-2B0578050C4C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC54911E-C432-48FA-9551-9644422FFE14",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A2C12934-E79C-41A4-B023-BADD7D68CB55",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFCCB68C-A58D-4543-A11F-721B01FFBBA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D288227C-69C1-4248-AB4A-51F44A41FDEA",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FE3716E-1C0A-4B72-809A-8318E5853FB1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FB34E83-83A3-45C3-B040-D8910971D439",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "91EDD23A-1DBD-4117-9396-89ADBC705B3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC54880F-CBF4-4772-A4FB-B07D97287D44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AF07B014-1BA3-477E-A405-5DB35F68126A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "80502856-7617-4ED9-A103-681021131EE0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7178F049-8E48-4175-AE8C-818128205D33",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7327CDF-EF0D-443B-A822-D69669C3B80C",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C7DDB0D1-21AC-43AC-9DDF-C6D89D3F1AA1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FAB9D2E-94BC-4C90-ADF3-27FB34FC23A9",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3003D9C7-A979-4289-AADD-190A55434F31",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1A0E6F26-15BE-4586-8ACD-1DAF9492A7D7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED3A29A7-F1B0-4A2C-AB63-6E4A57A6864D",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4EFEB827-71F1-4DDF-B156-949AF8E39A34",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1B191270-07F7-4173-833A-7F4929F643BF",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC590D4F-C818-4CD8-A8E9-E2A951E5D768",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "804E37AB-9EE4-4931-A874-4FBD427252D1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6AABE919-D289-43CB-A285-3212E630B313",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CA08C94B-BE44-49D1-AB10-7512F65D6DF1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "578CE1DA-BA53-4EA5-AB2D-4670321DDF81",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFEA3FDE-9575-4E9B-BE5F-6BEB005381D8",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "5FC77B9E-9081-44E0-82AF-0411940B0684",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED6AD6D3-75AC-4C7E-9471-8288FB7AABA4",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D51DCE8E-2E29-4969-A26B-A1A10220CA83",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F4F3FB17-F6E8-4BB1-B910-C9F03B936C32",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DF97E576-EBD2-4F1F-BE8F-4254D134565B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0378595B-379F-4775-B5D9-CCAC4042F635",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8A03BBB2-9650-4C8A-A137-0C8AC6CDAD66",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BCD1CF2-F24A-4C47-9C88-340E67C77871",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4DAD438B-DABE-4B9A-9CDB-9BAC16313F0F",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E1F3FE19-E279-4280-8F67-0C085B083E10",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED7BCCB2-CE77-45A3-A6E1-D591894847C7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7C43419-B7AA-40EB-A40D-840F975BE2EC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "580A5BD5-2E8E-4801-BFE8-7476088F4214",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FFAC6598-DDAC-4873-9545-39B0EF21D478",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "561064E3-FC05-4028-B75D-4D2519FEFD24",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4303ED83-6610-458F-BEE9-B99BA31DD962",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "475E5069-C120-4D49-AB9D-D3C3F94BD093",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "41614C70-97B4-44C8-A441-530A413A26F9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "274E5C49-CA32-44D2-A864-C99A48CAA869",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6751FB7D-C72C-4321-B535-5880FE696FC3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CD13707-1164-415E-9083-7946D151F1FC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0F1AE867-67B4-4871-BF56-88017533A737",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3A09FF2D-F369-47B5-AEE4-A862BEDD9851",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "69285324-4C0B-4BDC-B60D-F653679DD52D",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0BBC3005-41D0-4BA0-A146-E48E612CAF58",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "85B917B7-81E1-4419-B493-1D321027017E",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FCBEE10A-7E96-4239-AE6C-5FA9A6A32196",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "42288C48-A2AA-4AA1-B5A2-F83C5A3689AE",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "57E5489B-277A-4D02-B4AB-4DB65969EED2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFCDC84E-0695-409A-844B-D24024CC33F2",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B40D2EB-5C69-47FA-801B-DC48407D418C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1DB6C03-71BF-4359-834B-384E78910E64",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8082D4C1-C59E-43B6-B11F-C814ACD00321",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34349AEF-170F-432F-8D64-347F08536D3A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EACF7493-4FE6-4902-9EE7-76F1B4AB118A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3237051D-0342-4DB8-B4A1-40A3B33A67BB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4969C410-25DF-4BFA-9125-53D63B33691B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B4A2ED6E-6632-4DD9-A359-73EB28BB306B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3B54DF8C-BB5A-46AF-862D-DC8E984A05AB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF74FFD-81C8-4E63-8B7B-AEBD98AB34F7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.",
      },
      {
         lang: "es",
         value: "Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluyendo Variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.2.5), familia de switches SCALANCE X-200IRT (incluyendo la variante SIPLUS NET) (Todas las versiones anteriores a la versión V5.5.0). Los dispositivos crean una nueva clave única tras el restablecimiento de fábrica, excepto cuando se usan con C-PLUG. Cuando se usa con C-PLUG, los dispositivos usan la clave RSA privada embebida que se envía con la imagen del firmware. Un atacante podría aprovechar esta situación en una situación de man-in-the-middle y descifrar el tráfico capturado previamente",
      },
   ],
   id: "CVE-2020-28391",
   lastModified: "2024-11-21T05:22:42.433",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "MEDIUM",
            cvssData: {
               accessComplexity: "MEDIUM",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "NONE",
               baseScore: 4.3,
               confidentialityImpact: "PARTIAL",
               integrityImpact: "NONE",
               vectorString: "AV:N/AC:M/Au:N/C:P/I:N/A:N",
               version: "2.0",
            },
            exploitabilityScore: 8.6,
            impactScore: 2.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "HIGH",
               attackVector: "NETWORK",
               availabilityImpact: "NONE",
               baseScore: 5.9,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "HIGH",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
               version: "3.1",
            },
            exploitabilityScore: 2.2,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2021-01-12T21:15:18.120",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf",
      },
      {
         source: "productcert@siemens.com",
         tags: [
            "Third Party Advisory",
            "US Government Resource",
            "Vendor Advisory",
         ],
         url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Third Party Advisory",
            "US Government Resource",
            "Vendor Advisory",
         ],
         url: "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-321",
            },
         ],
         source: "productcert@siemens.com",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-798",
            },
         ],
         source: "nvd@nist.gov",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 07:12
Summary
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.
Impacted products
Vendor Product Version
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_sc-600_firmware *
siemens scalance_sc-600 -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w700_ieee_802.11ax_firmware *
siemens scalance_w700_ieee_802.11ax -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_w700_ieee_802.11ac_firmware *
siemens scalance_w700_ieee_802.11ac -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xm408-4c_firmware *
siemens scalance_xm408-4c -
siemens scalance_xm408-4c_l3_firmware *
siemens scalance_xm408-4c_l3 -
siemens scalance_xm408-8c_firmware *
siemens scalance_xm408-8c -
siemens scalance_xm408-8c_l3_firmware *
siemens scalance_xm408-8c_l3 -
siemens scalance_xm416-4c_firmware *
siemens scalance_xm416-4c -
siemens scalance_xm416-4c_l3_firmware *
siemens scalance_xm416-4c_l3 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -
siemens scalance_xr-300_firmware *
siemens scalance_xr-300 -
siemens scalance_xr-300eec_firmware *
siemens scalance_xr-300eec -
siemens scalance_xr-300poe_firmware *
siemens scalance_xr-300poe -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324wg_firmware *
siemens scalance_xr324wg -
siemens scalance_xr326-2c_poe_wg_firmware *
siemens scalance_xr326-2c_poe_wg -
siemens scalance_xr328-4c_wg_firmware *
siemens scalance_xr328-4c_wg -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr524-8c_l3_firmware *
siemens scalance_xr524-8c_l3 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr526-8c_l3_firmware *
siemens scalance_xr526-8c_l3 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr528-6m_2hr2_firmware *
siemens scalance_xr528-6m_2hr2 -
siemens scalance_xr528-6m_2hr2_l3_firmware *
siemens scalance_xr528-6m_2hr2_l3 -
siemens scalance_xr528-6m_l3_firmware *
siemens scalance_xr528-6m_l3 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens scalance_xr552-12m_firmware *
siemens scalance_xr552-12m -
siemens scalance_xr552-12m_2hr2_firmware *
siemens scalance_xr552-12m_2hr2 -
siemens scalance_xr552-12m_2hr2_l3_firmware *
siemens scalance_xr552-12m_2hr2_l3 -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A43ECBDD-F831-4364-8869-C696D1AC531A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFB9921A-5204-40A3-88AB-B7755F5C6875",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E917CBBB-EF41-4113-B0CA-EB91889235E7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "269D399D-1B5B-46FE-A05F-90405CBC81B1",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6A728A54-3FCD-46C8-89C7-D145484BF8DF",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "50FEE5FA-B141-4E5F-8673-363089262530",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "67B6AD24-FB63-4779-BFA0-B6849254A45C",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "780BDF7D-4E7F-4A45-9E7B-D261031DA24D",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F28978FB-B7F0-4D0E-9498-86F0E6B291DE",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "10C7D54A-27B4-4195-8131-DD5380472A75",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4CDE958F-2E63-4870-A9CD-6A0E0224B590",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E54AF1E6-0E52-447C-8946-18716D30EBE2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "09908B6A-6655-42F0-A20B-79FFBF81937A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F05D6764-79B4-4787-B2D2-E685910453C3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "880644DA-9280-4498-AD72-5CBD59CC8142",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C93984BD-70E6-496C-BA20-18464B0E84B3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E673B450-C436-49F3-B2F3-872B704FE075",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D0113244-9647-4E95-B1E4-DBD26ADD3786",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "692B60D5-696D-4680-BB38-3C0EC0F2D034",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C08F92C8-0A5D-470E-8CFC-F622C3014336",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1C93B717-35A4-4824-9B85-DB046E38DA33",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "82708B62-47F9-4909-A52C-D96BC3AA567D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "316A0742-A32F-453E-922A-F084D9BEAA19",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "62C9A709-2AB4-4836-B925-988D78AEB278",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "429647B3-1C26-42EF-94DC-B9630AA627CD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D2F04D78-74F0-4471-9AF6-54EA822F1992",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "09F27730-5DB8-4736-B6ED-A46C3888F48D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2EA0205D-A280-4903-927A-AC4FEC051E2A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFF36832-3023-4AEA-800E-ED4D87271E3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9089DA8-FEF8-4927-B56A-139B67571671",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34F19168-C521-4D67-BF88-1551F079859E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "58377C58-F660-4C17-A3CB-BFC2F28848CD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4F316894-3BBB-4B72-8636-23868BF557AB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "813D5C37-C5CF-4B50-920A-38C9CF042966",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2AA81823-013F-4990-B62D-86C404F04BCB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "24722F13-7DA7-4CA6-A141-293DE72B15B4",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFE568ED-3604-428E-82E7-4027CB2DDD62",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78562689-B494-4500-9725-B418F1EC3CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "F9102A41-5812-4014-BC07-E571E815ED49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "04B56011-74F9-4760-A4AD-850F0CCF0B62",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3491A486-47F3-4B30-B613-DCC412F6EF5B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "54BB088B-67FC-4C34-98A0-EC05B67B2396",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E5AAC31E-42DE-423E-8F43-A5600E24160F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7E0BC528-5B72-48AB-A70A-B116770A8587",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "18D7E470-D872-4C37-8669-B66328F173D6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F51CE85F-16D1-4E49-83C7-70C90233E294",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B357AD42-1806-4BE5-B76D-F798E475F659",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "889CF2C0-EE6C-447F-85F1-005730EAD232",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "18537338-DF5C-4F7A-995E-7F953B380657",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "36C9AE74-4683-4ED0-A605-3A6B065C230E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4356417E-B4CB-45B0-B395-CE9D423FAB44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F952542-6B79-4681-A236-15C188AAEB1E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "664D9C76-BC13-4874-939C-A8211DA33903",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "82D18854-D803-40C6-BB14-A28594C37CDB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E767C461-8FA6-4700-98CB-734AFD309140",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CBD19EFB-12D2-4401-B87A-91873528E474",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "080E722F-FCD4-4967-86EE-151ADC5702E7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1509C8A-89FC-445D-BB22-BF9A811E853B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8709D27F-90B9-4AF8-8784-E974CE859518",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "756A07F8-4F9F-4A76-942E-82CB92216943",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "554455C1-19FF-4F71-BC36-13DDE7FE0087",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67661569-6233-4C74-9C72-88BD14B257FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "10F66ADC-91EC-4ED0-B768-03F94241B300",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "3E048C4A-A414-4C87-A865-4D4218AE32EE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "03DFEC43-5E84-460A-A50E-6BF378E83A70",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "64CCA458-1F7F-44ED-ACD5-E9355B112194",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "81355370-BE69-434F-ABAC-8611F9909E46",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AB16A0BE-5AF3-4168-B755-D023E497A35F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B490BBD4-458F-4077-8404-9208499226E7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "09743616-31C9-4E47-8A4A-B15D76204BE7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "87B35693-9D07-4507-8070-43B8F756F772",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B05DE63D-186B-46CC-B3CE-66923F290B6B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA9921B1-38FD-4404-9986-3023C577FE5C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "Affected devices do not properly sanitize an input field.  This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.",
      },
      {
         lang: "es",
         value: "Los dispositivos afectados no sanean correctamente un campo de entrada. Esto podría permitir a un atacante remoto autenticado con privilegios administrativos inyectar código o generar un shell de raíz del sistema",
      },
   ],
   id: "CVE-2022-36323",
   lastModified: "2024-11-21T07:12:47.000",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.1,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "HIGH",
               scope: "CHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 2.3,
            impactScore: 6,
            source: "productcert@siemens.com",
            type: "Primary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 7.2,
               baseSeverity: "HIGH",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "HIGH",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 1.2,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Secondary",
         },
      ],
   },
   published: "2022-08-10T12:15:12.863",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Patch",
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Patch",
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-74",
            },
         ],
         source: "productcert@siemens.com",
         type: "Secondary",
      },
      {
         description: [
            {
               lang: "en",
               value: "NVD-CWE-Other",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 07:12
Summary
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
Impacted products
Vendor Product Version
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_sc-600_firmware *
siemens scalance_sc-600 -
siemens scalance_sc622-2c_firmware *
siemens scalance_sc622-2c -
siemens scalance_sc632-2c_firmware *
siemens scalance_sc632-2c -
siemens scalance_sc636-2c_firmware *
siemens scalance_sc636-2c -
siemens scalance_sc642-2c_firmware *
siemens scalance_sc642-2c -
siemens scalance_sc646-2c_firmware *
siemens scalance_sc646-2c -
siemens scalance_w700_ieee_802.11ax_firmware *
siemens scalance_w700_ieee_802.11ax -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_w700_ieee_802.11ac_firmware *
siemens scalance_w700_ieee_802.11ac -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xm408-4c_firmware *
siemens scalance_xm408-4c -
siemens scalance_xm408-4c_l3_firmware *
siemens scalance_xm408-4c_l3 -
siemens scalance_xm408-8c_firmware *
siemens scalance_xm408-8c -
siemens scalance_xm408-8c_l3_firmware *
siemens scalance_xm408-8c_l3 -
siemens scalance_xm416-4c_firmware *
siemens scalance_xm416-4c -
siemens scalance_xm416-4c_l3_firmware *
siemens scalance_xm416-4c_l3 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -
siemens scalance_xr-300_firmware *
siemens scalance_xr-300 -
siemens scalance_xr-300eec_firmware *
siemens scalance_xr-300eec -
siemens scalance_xr-300poe_firmware *
siemens scalance_xr-300poe -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324wg_firmware *
siemens scalance_xr324wg -
siemens scalance_xr326-2c_poe_wg_firmware *
siemens scalance_xr326-2c_poe_wg -
siemens scalance_xr328-4c_wg_firmware *
siemens scalance_xr328-4c_wg -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr524-8c_l3_firmware *
siemens scalance_xr524-8c_l3 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr526-8c_l3_firmware *
siemens scalance_xr526-8c_l3 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr528-6m_2hr2_firmware *
siemens scalance_xr528-6m_2hr2 -
siemens scalance_xr528-6m_2hr2_l3_firmware *
siemens scalance_xr528-6m_2hr2_l3 -
siemens scalance_xr528-6m_l3_firmware *
siemens scalance_xr528-6m_l3 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens scalance_xr552-12m_firmware *
siemens scalance_xr552-12m -
siemens scalance_xr552-12m_2hr2_firmware *
siemens scalance_xr552-12m_2hr2 -
siemens scalance_xr552-12m_2hr2_l3_firmware *
siemens scalance_xr552-12m_2hr2_l3 -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A43ECBDD-F831-4364-8869-C696D1AC531A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFB9921A-5204-40A3-88AB-B7755F5C6875",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E917CBBB-EF41-4113-B0CA-EB91889235E7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "269D399D-1B5B-46FE-A05F-90405CBC81B1",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc622-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6A728A54-3FCD-46C8-89C7-D145484BF8DF",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc622-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "50FEE5FA-B141-4E5F-8673-363089262530",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc632-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "67B6AD24-FB63-4779-BFA0-B6849254A45C",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc632-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8A79836B-5EC1-40AF-8A57-9657EF6758E5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc636-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "780BDF7D-4E7F-4A45-9E7B-D261031DA24D",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc636-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FCB9BD17-7F1F-42E9-831F-EB907F9BC214",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc642-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F28978FB-B7F0-4D0E-9498-86F0E6B291DE",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc642-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "10C7D54A-27B4-4195-8131-DD5380472A75",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_sc646-2c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4CDE958F-2E63-4870-A9CD-6A0E0224B590",
                     versionEndExcluding: "2.3.1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_sc646-2c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E54AF1E6-0E52-447C-8946-18716D30EBE2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "09908B6A-6655-42F0-A20B-79FFBF81937A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F05D6764-79B4-4787-B2D2-E685910453C3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "880644DA-9280-4498-AD72-5CBD59CC8142",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C93984BD-70E6-496C-BA20-18464B0E84B3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E673B450-C436-49F3-B2F3-872B704FE075",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D0113244-9647-4E95-B1E4-DBD26ADD3786",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "692B60D5-696D-4680-BB38-3C0EC0F2D034",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C08F92C8-0A5D-470E-8CFC-F622C3014336",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1C93B717-35A4-4824-9B85-DB046E38DA33",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "82708B62-47F9-4909-A52C-D96BC3AA567D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "316A0742-A32F-453E-922A-F084D9BEAA19",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "62C9A709-2AB4-4836-B925-988D78AEB278",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "429647B3-1C26-42EF-94DC-B9630AA627CD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D2F04D78-74F0-4471-9AF6-54EA822F1992",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "09F27730-5DB8-4736-B6ED-A46C3888F48D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2EA0205D-A280-4903-927A-AC4FEC051E2A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFF36832-3023-4AEA-800E-ED4D87271E3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9089DA8-FEF8-4927-B56A-139B67571671",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34F19168-C521-4D67-BF88-1551F079859E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "58377C58-F660-4C17-A3CB-BFC2F28848CD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4F316894-3BBB-4B72-8636-23868BF557AB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "813D5C37-C5CF-4B50-920A-38C9CF042966",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2AA81823-013F-4990-B62D-86C404F04BCB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "24722F13-7DA7-4CA6-A141-293DE72B15B4",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFE568ED-3604-428E-82E7-4027CB2DDD62",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78562689-B494-4500-9725-B418F1EC3CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "F9102A41-5812-4014-BC07-E571E815ED49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "04B56011-74F9-4760-A4AD-850F0CCF0B62",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3491A486-47F3-4B30-B613-DCC412F6EF5B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "54BB088B-67FC-4C34-98A0-EC05B67B2396",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E5AAC31E-42DE-423E-8F43-A5600E24160F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7E0BC528-5B72-48AB-A70A-B116770A8587",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "18D7E470-D872-4C37-8669-B66328F173D6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F51CE85F-16D1-4E49-83C7-70C90233E294",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B357AD42-1806-4BE5-B76D-F798E475F659",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "889CF2C0-EE6C-447F-85F1-005730EAD232",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "18537338-DF5C-4F7A-995E-7F953B380657",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "36C9AE74-4683-4ED0-A605-3A6B065C230E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4356417E-B4CB-45B0-B395-CE9D423FAB44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F952542-6B79-4681-A236-15C188AAEB1E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "664D9C76-BC13-4874-939C-A8211DA33903",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "82D18854-D803-40C6-BB14-A28594C37CDB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E767C461-8FA6-4700-98CB-734AFD309140",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CBD19EFB-12D2-4401-B87A-91873528E474",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "080E722F-FCD4-4967-86EE-151ADC5702E7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1509C8A-89FC-445D-BB22-BF9A811E853B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8709D27F-90B9-4AF8-8784-E974CE859518",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "756A07F8-4F9F-4A76-942E-82CB92216943",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "554455C1-19FF-4F71-BC36-13DDE7FE0087",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67661569-6233-4C74-9C72-88BD14B257FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "10F66ADC-91EC-4ED0-B768-03F94241B300",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "3E048C4A-A414-4C87-A865-4D4218AE32EE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "03DFEC43-5E84-460A-A50E-6BF378E83A70",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "64CCA458-1F7F-44ED-ACD5-E9355B112194",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "81355370-BE69-434F-ABAC-8611F9909E46",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AB16A0BE-5AF3-4168-B755-D023E497A35F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B490BBD4-458F-4077-8404-9208499226E7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "09743616-31C9-4E47-8A4A-B15D76204BE7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "87B35693-9D07-4507-8070-43B8F756F772",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B05DE63D-186B-46CC-B3CE-66923F290B6B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA9921B1-38FD-4404-9986-3023C577FE5C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.",
      },
      {
         lang: "es",
         value: "Los dispositivos afectados no sanean correctamente los datos introducidos por un usuario al renderizar la interfaz web. Esto podría permitir a un atacante remoto autenticado con privilegios administrativos inyectar código y llevar a un XSS basado en el DOM",
      },
   ],
   id: "CVE-2022-36325",
   lastModified: "2024-11-21T07:12:47.637",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 6.8,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "HIGH",
               scope: "UNCHANGED",
               userInteraction: "REQUIRED",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 0.9,
            impactScore: 5.9,
            source: "productcert@siemens.com",
            type: "Secondary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "NONE",
               baseScore: 4.8,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "LOW",
               integrityImpact: "LOW",
               privilegesRequired: "HIGH",
               scope: "CHANGED",
               userInteraction: "REQUIRED",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
               version: "3.1",
            },
            exploitabilityScore: 1.7,
            impactScore: 2.7,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2022-08-10T12:15:12.997",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Mitigation",
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Mitigation",
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-80",
            },
         ],
         source: "productcert@siemens.com",
         type: "Secondary",
      },
      {
         description: [
            {
               lang: "en",
               value: "NVD-CWE-Other",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2021-01-12 21:15
Modified
2024-11-21 05:06
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
Impacted products
Vendor Product Version
siemens scalance_x200-4pirt_firmware *
siemens scalance_x200-4pirt -
siemens scalance_x201-3pirt_firmware *
siemens scalance_x201-3pirt -
siemens scalance_x202-2irt_firmware *
siemens scalance_x202-2irt -
siemens scalance_x202-2pirt_firmware *
siemens scalance_x202-2pirt -
siemens scalance_x202-2pirt_siplus_net_firmware *
siemens scalance_x202-2pirt_siplus_net -
siemens scalance_x204irt_firmware *
siemens scalance_x204irt -
siemens scalance_x307-3_firmware *
siemens scalance_x307-3 -
siemens scalance_x307-3ld_firmware *
siemens scalance_x307-3ld -
siemens scalance_x308-2_firmware *
siemens scalance_x308-2 -
siemens scalance_x308-2ld_firmware *
siemens scalance_x308-2ld -
siemens scalance_x308-2lh_firmware *
siemens scalance_x308-2lh -
siemens scalance_x308-2lh\+_firmware *
siemens scalance_x308-2lh\+ -
siemens scalance_x308-2m_firmware *
siemens scalance_x308-2m -
siemens scalance_x308-2m_ts_firmware *
siemens scalance_x308-2m_ts -
siemens scalance_x310_firmware *
siemens scalance_x310 -
siemens scalance_x310fe_firmware *
siemens scalance_x310fe -
siemens scalance_x320-1fe_firmware *
siemens scalance_x320-1fe -
siemens scalance_x320-3ldfe_firmware *
siemens scalance_x320-3ldfe -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware *
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xf201-3p_irt_firmware *
siemens scalance_xf201-3p_irt -
siemens scalance_xf202-2p_irt_firmware *
siemens scalance_xf202-2p_irt -
siemens scalance_xf204_firmware *
siemens scalance_xf204 -
siemens scalance_xf204-2_firmware *
siemens scalance_xf204-2 -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xf204_dna_firmware *
siemens scalance_xf204_dna -
siemens scalance_xf204irt_firmware *
siemens scalance_xf204irt -
siemens scalance_xf206-1_firmware *
siemens scalance_xf206-1 -
siemens scalance_xf208_firmware *
siemens scalance_xf208 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "43B261ED-08C4-4A0D-8BAC-221006AB6F93",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FDCB432-1AD0-4BF1-839F-8091D9871831",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "53F56390-77CB-42D5-A603-5FB29EE5DAA5",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "47498977-D642-4864-BB94-4CE077EDEB82",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "666FACCE-89EB-4E5D-A718-F1D4945F7DF4",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A8B1D979-038F-42F4-AB7D-E0664D051B4E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B79AD48F-2B99-4BE5-B3D7-440E2D3BC699",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7819B14-7E93-4D0F-AAD5-049BE3B36D07",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CD18B3BE-E98D-46D1-AA10-89EB89BAFFEB",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DABC3436-E04E-4B6C-9EF4-47B08C57B166",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C94D093-9D17-47C9-A7F6-28FF241BF874",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9676DB10-982D-445F-9779-B39AE720AF2F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "48D3EB09-6069-4289-A61E-C15B044EA2E2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7737F0C2-43FC-4330-88F2-9B08BA5B35D7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "40A1A5F9-4971-4E9D-BBE7-5A0357C56213",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FE1909FA-C8C6-46BE-83C6-2635D36FE69B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F53C74B-2154-417E-ACFE-01F0BACD3F15",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6DDBD94D-5312-4A54-AF76-D9DF791C0292",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D76A2268-5397-466C-98B5-01B46B4840A1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "85153EED-C677-495D-A6BB-72365DE1ED3F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2F8888A7-3285-4ACA-A5AD-2B0578050C4C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC54911E-C432-48FA-9551-9644422FFE14",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A2C12934-E79C-41A4-B023-BADD7D68CB55",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFCCB68C-A58D-4543-A11F-721B01FFBBA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D288227C-69C1-4248-AB4A-51F44A41FDEA",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FE3716E-1C0A-4B72-809A-8318E5853FB1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FB34E83-83A3-45C3-B040-D8910971D439",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "91EDD23A-1DBD-4117-9396-89ADBC705B3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC54880F-CBF4-4772-A4FB-B07D97287D44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AF07B014-1BA3-477E-A405-5DB35F68126A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "80502856-7617-4ED9-A103-681021131EE0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7178F049-8E48-4175-AE8C-818128205D33",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7327CDF-EF0D-443B-A822-D69669C3B80C",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C7DDB0D1-21AC-43AC-9DDF-C6D89D3F1AA1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FAB9D2E-94BC-4C90-ADF3-27FB34FC23A9",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3003D9C7-A979-4289-AADD-190A55434F31",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1A0E6F26-15BE-4586-8ACD-1DAF9492A7D7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED3A29A7-F1B0-4A2C-AB63-6E4A57A6864D",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4EFEB827-71F1-4DDF-B156-949AF8E39A34",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1B191270-07F7-4173-833A-7F4929F643BF",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC590D4F-C818-4CD8-A8E9-E2A951E5D768",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "804E37AB-9EE4-4931-A874-4FBD427252D1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6AABE919-D289-43CB-A285-3212E630B313",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CA08C94B-BE44-49D1-AB10-7512F65D6DF1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "578CE1DA-BA53-4EA5-AB2D-4670321DDF81",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFEA3FDE-9575-4E9B-BE5F-6BEB005381D8",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "5FC77B9E-9081-44E0-82AF-0411940B0684",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED6AD6D3-75AC-4C7E-9471-8288FB7AABA4",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D51DCE8E-2E29-4969-A26B-A1A10220CA83",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F4F3FB17-F6E8-4BB1-B910-C9F03B936C32",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DF97E576-EBD2-4F1F-BE8F-4254D134565B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0378595B-379F-4775-B5D9-CCAC4042F635",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8A03BBB2-9650-4C8A-A137-0C8AC6CDAD66",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BCD1CF2-F24A-4C47-9C88-340E67C77871",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4DAD438B-DABE-4B9A-9CDB-9BAC16313F0F",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E1F3FE19-E279-4280-8F67-0C085B083E10",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED7BCCB2-CE77-45A3-A6E1-D591894847C7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7C43419-B7AA-40EB-A40D-840F975BE2EC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "580A5BD5-2E8E-4801-BFE8-7476088F4214",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FFAC6598-DDAC-4873-9545-39B0EF21D478",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "561064E3-FC05-4028-B75D-4D2519FEFD24",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4303ED83-6610-458F-BEE9-B99BA31DD962",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "475E5069-C120-4D49-AB9D-D3C3F94BD093",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "41614C70-97B4-44C8-A441-530A413A26F9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "274E5C49-CA32-44D2-A864-C99A48CAA869",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6751FB7D-C72C-4321-B535-5880FE696FC3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CD13707-1164-415E-9083-7946D151F1FC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0F1AE867-67B4-4871-BF56-88017533A737",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3A09FF2D-F369-47B5-AEE4-A862BEDD9851",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "69285324-4C0B-4BDC-B60D-F653679DD52D",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0BBC3005-41D0-4BA0-A146-E48E612CAF58",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "85B917B7-81E1-4419-B493-1D321027017E",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FCBEE10A-7E96-4239-AE6C-5FA9A6A32196",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "42288C48-A2AA-4AA1-B5A2-F83C5A3689AE",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "57E5489B-277A-4D02-B4AB-4DB65969EED2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFCDC84E-0695-409A-844B-D24024CC33F2",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B40D2EB-5C69-47FA-801B-DC48407D418C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1DB6C03-71BF-4359-834B-384E78910E64",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8082D4C1-C59E-43B6-B11F-C814ACD00321",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34349AEF-170F-432F-8D64-347F08536D3A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EACF7493-4FE6-4902-9EE7-76F1B4AB118A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3237051D-0342-4DB8-B4A1-40A3B33A67BB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4969C410-25DF-4BFA-9125-53D63B33691B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B4A2ED6E-6632-4DD9-A359-73EB28BB306B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3B54DF8C-BB5A-46AF-862D-DC8E984A05AB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF74FFD-81C8-4E63-8B7B-AEBD98AB34F7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.",
      },
      {
         lang: "es",
         value: "Se ha identificado una vulnerabilidad en la familia de switches (incluyendo las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.2.5), familia de switches SCALANCE X-200IRT (incluyendo las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.5.0). La vulnerabilidad podría permitir a un atacante no autenticado reiniciar el dispositivo a través de la red mediante el uso de direcciones URL especiales del servidor web integrado de los productos afectados",
      },
   ],
   id: "CVE-2020-15799",
   lastModified: "2024-11-21T05:06:12.267",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "MEDIUM",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "COMPLETE",
               baseScore: 7.1,
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               vectorString: "AV:N/AC:M/Au:N/C:N/I:N/A:C",
               version: "2.0",
            },
            exploitabilityScore: 8.6,
            impactScore: 6.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: true,
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 6.5,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "REQUIRED",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
               version: "3.1",
            },
            exploitabilityScore: 2.8,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2021-01-12T21:15:16.370",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-306",
            },
         ],
         source: "productcert@siemens.com",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-306",
            },
         ],
         source: "nvd@nist.gov",
         type: "Secondary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2022-08-10 12:15
Modified
2024-11-21 07:12
Summary
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
Impacted products
Vendor Product Version
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_w700_ieee_802.11ax_firmware *
siemens scalance_w700_ieee_802.11ax -
siemens scalance_w700_ieee_802.11n_firmware *
siemens scalance_w700_ieee_802.11n -
siemens scalance_w700_ieee_802.11ac_firmware *
siemens scalance_w700_ieee_802.11ac -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xm400_firmware *
siemens scalance_xm400 -
siemens scalance_xm408-4c_firmware *
siemens scalance_xm408-4c -
siemens scalance_xm408-4c_l3_firmware *
siemens scalance_xm408-4c_l3 -
siemens scalance_xm408-8c_firmware *
siemens scalance_xm408-8c -
siemens scalance_xm408-8c_l3_firmware *
siemens scalance_xm408-8c_l3 -
siemens scalance_xm416-4c_firmware *
siemens scalance_xm416-4c -
siemens scalance_xm416-4c_l3_firmware *
siemens scalance_xm416-4c_l3 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -
siemens scalance_xr-300_firmware *
siemens scalance_xr-300 -
siemens scalance_xr-300eec_firmware *
siemens scalance_xr-300eec -
siemens scalance_xr-300poe_firmware *
siemens scalance_xr-300poe -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr324-12m_firmware *
siemens scalance_xr324-12m -
siemens scalance_xr324-12m_ts_firmware *
siemens scalance_xr324-12m_ts -
siemens scalance_xr324-4m_eec_firmware *
siemens scalance_xr324-4m_eec -
siemens scalance_xr324-4m_poe_firmware *
siemens scalance_xr324-4m_poe -
siemens scalance_xr324-4m_poe_ts_firmware *
siemens scalance_xr324-4m_poe_ts -
siemens scalance_xr324wg_firmware *
siemens scalance_xr324wg -
siemens scalance_xr326-2c_poe_wg_firmware *
siemens scalance_xr326-2c_poe_wg -
siemens scalance_xr328-4c_wg_firmware *
siemens scalance_xr328-4c_wg -
siemens scalance_xr500_firmware *
siemens scalance_xr500 -
siemens scalance_xr524_firmware *
siemens scalance_xr524 -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr524-8c_l3_firmware *
siemens scalance_xr524-8c_l3 -
siemens scalance_xr526_firmware *
siemens scalance_xr526 -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr526-8c_l3_firmware *
siemens scalance_xr526-8c_l3 -
siemens scalance_xr528_firmware *
siemens scalance_xr528 -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr528-6m_2hr2_firmware *
siemens scalance_xr528-6m_2hr2 -
siemens scalance_xr528-6m_2hr2_l3_firmware *
siemens scalance_xr528-6m_2hr2_l3 -
siemens scalance_xr528-6m_l3_firmware *
siemens scalance_xr528-6m_l3 -
siemens scalance_xr552_firmware *
siemens scalance_xr552 -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens scalance_xr552-12m_firmware *
siemens scalance_xr552-12m -
siemens scalance_xr552-12m_2hr2_firmware *
siemens scalance_xr552-12m_2hr2 -
siemens scalance_xr552-12m_2hr2_l3_firmware *
siemens scalance_xr552-12m_2hr2_l3 -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A43ECBDD-F831-4364-8869-C696D1AC531A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFB9921A-5204-40A3-88AB-B7755F5C6875",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6EF65A06-2222-47D2-83B5-4C61E6D8731E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E917CBBB-EF41-4113-B0CA-EB91889235E7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ax_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "23DDDAEC-C0B4-4E14-9840-101B6F24DBE5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ax:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "09908B6A-6655-42F0-A20B-79FFBF81937A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11n_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F05D6764-79B4-4787-B2D2-E685910453C3",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11n:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "880644DA-9280-4498-AD72-5CBD59CC8142",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_w700_ieee_802.11ac_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8D7CF655-D174-4CE8-A2AC-C14967A8283B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_w700_ieee_802.11ac:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C93984BD-70E6-496C-BA20-18464B0E84B3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E673B450-C436-49F3-B2F3-872B704FE075",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CB0BE85-4A96-45EB-9EAA-A2D9E5D45508",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9E6A2AB-7F15-4ABB-B00A-F5667B615ABE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "713ADE75-1915-4DBB-9FC3-59E9A03AB5A8",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D0113244-9647-4E95-B1E4-DBD26ADD3786",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "692B60D5-696D-4680-BB38-3C0EC0F2D034",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D83C08F3-C6F7-46D1-B3F6-0173F9B7E983",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C08F92C8-0A5D-470E-8CFC-F622C3014336",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1C93B717-35A4-4824-9B85-DB046E38DA33",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4F02CFE9-6058-4B0D-9FD5-6C84ED4A3EAD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C4EA7C54-4200-4E33-B2EA-0F82AA3ECD9D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4B9CA045-5DB1-422C-ABE2-AC89F5A27847",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "81AD4EB0-A125-4E4B-9348-AA6E670061B2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "82708B62-47F9-4909-A52C-D96BC3AA567D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "49EBEDA9-A826-45DD-A5BB-D5B55FB47B60",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "822CB559-BAFC-4674-A64B-BDCF1AAFDD0E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "316A0742-A32F-453E-922A-F084D9BEAA19",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "62C9A709-2AB4-4836-B925-988D78AEB278",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "17E1B7ED-A272-43C6-9CA5-4CF370F8ED1C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1ABF1FC1-2FB5-42D8-867C-0B93AB67C096",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "429647B3-1C26-42EF-94DC-B9630AA627CD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D2F04D78-74F0-4471-9AF6-54EA822F1992",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "00C80C92-FC92-4B96-8B80-6F7E0B07EBAD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AA3B23C3-8880-4640-A6B2-EA870A85AAFE",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2765D0D-9A77-45E5-9F58-BF877E6F94B7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "09F27730-5DB8-4736-B6ED-A46C3888F48D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A5A04F9F-133C-4C02-BA65-CABA47E1F329",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2EA0205D-A280-4903-927A-AC4FEC051E2A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFF36832-3023-4AEA-800E-ED4D87271E3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "33C3BB4B-63C9-4770-9CC0-053A0B655ED7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9089DA8-FEF8-4927-B56A-139B67571671",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34F19168-C521-4D67-BF88-1551F079859E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "58377C58-F660-4C17-A3CB-BFC2F28848CD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A6C7A93D-B629-4A56-B961-5D4FD012E6E6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4F316894-3BBB-4B72-8636-23868BF557AB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6BF5436-1BCB-4945-8F2D-68F766D3567F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9FC408A8-903F-43A2-9D05-65AD4482FDBB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "813D5C37-C5CF-4B50-920A-38C9CF042966",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2AA81823-013F-4990-B62D-86C404F04BCB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-4c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0DFCB811-4CE6-4FA9-A722-86ED0D434FD9",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-4c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2FB222B-0414-4A1E-8BBD-6470CDB3BFF8",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "24722F13-7DA7-4CA6-A141-293DE72B15B4",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7096DBA5-95BB-44D7-B7CA-B1845C87F70E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm408-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFE568ED-3604-428E-82E7-4027CB2DDD62",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm408-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78562689-B494-4500-9725-B418F1EC3CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm416-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "616BB0A9-47FB-4F72-8241-0ADF50E6E236",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm416-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "F9102A41-5812-4014-BC07-E571E815ED49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xm416-4c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "04B56011-74F9-4760-A4AD-850F0CCF0B62",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xm416-4c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "86A2A766-9046-484F-9D49-4A1F4F0F96A4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3491A486-47F3-4B30-B613-DCC412F6EF5B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "54BB088B-67FC-4C34-98A0-EC05B67B2396",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BF3C7B31-25AA-4D74-AB2D-5C7F1D8025C1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DCFA1A9B-1130-46BC-9A5F-FFBB527517FF",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E5AAC31E-42DE-423E-8F43-A5600E24160F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7D5F9D33-F74A-4FFB-9327-5CE691F0C1D6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7E0BC528-5B72-48AB-A70A-B116770A8587",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "18D7E470-D872-4C37-8669-B66328F173D6",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F51CE85F-16D1-4E49-83C7-70C90233E294",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B357AD42-1806-4BE5-B76D-F798E475F659",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "889CF2C0-EE6C-447F-85F1-005730EAD232",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "17115730-97BF-473F-A4A7-03D5AE0F1A6D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF41E9F-4627-49EE-BCF1-08B5AADE964A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "18537338-DF5C-4F7A-995E-7F953B380657",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC118867-1A6C-4C3B-AD75-5D24551DB0BC",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "64A47C63-7150-4F8D-BFD9-2F5C2761DBDF",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0AC751E0-FC87-4DEB-85E8-C3E028B76482",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "36C9AE74-4683-4ED0-A605-3A6B065C230E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EB09860F-9DC8-476B-9AF7-6FFE57101D6C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4356417E-B4CB-45B0-B395-CE9D423FAB44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F952542-6B79-4681-A236-15C188AAEB1E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "664D9C76-BC13-4874-939C-A8211DA33903",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4834A67B-7B0B-4F88-BBFB-25667FD68EC5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr324wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "82D18854-D803-40C6-BB14-A28594C37CDB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr324wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E767C461-8FA6-4700-98CB-734AFD309140",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr326-2c_poe_wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4B7EC611-120E-4002-BF1E-4B45E431B7FC",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr326-2c_poe_wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CBD19EFB-12D2-4401-B87A-91873528E474",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr328-4c_wg_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AFA83BBC-C6F3-4F98-A92B-2611EACBC093",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr328-4c_wg:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A5B7DEDC-66BD-4701-BBDD-16273263ADC9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC8637DA-CA1E-46C6-AD1D-4F90B2A0BB35",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "080E722F-FCD4-4967-86EE-151ADC5702E7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA8C39A2-1989-49ED-91FC-7BCE7002F250",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7DEEA300-16C3-4FEE-88A8-674DE2AEEC95",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA970560-8AE2-49B1-BCD0-E7913DEA50ED",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr524-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC7CB42C-666C-4DFD-B3CB-DD9509363E94",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr524-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1509C8A-89FC-445D-BB22-BF9A811E853B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr526_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8709D27F-90B9-4AF8-8784-E974CE859518",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "756A07F8-4F9F-4A76-942E-82CB92216943",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "554455C1-19FF-4F71-BC36-13DDE7FE0087",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67661569-6233-4C74-9C72-88BD14B257FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "10F66ADC-91EC-4ED0-B768-03F94241B300",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr526-8c_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0921AD23-44BA-4F5C-9DC8-A5F90753C977",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F41F6AE6-0E43-4D12-B379-FCF3A2A104DB",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FDE5E54D-FFED-4C2C-B89D-E085E61D44E4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B0630BF0-8EFD-425A-A371-E1B0E5074D4D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "3E048C4A-A414-4C87-A865-4D4218AE32EE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DEAA4C6F-F234-4895-9D0D-B89E3F07F038",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "03DFEC43-5E84-460A-A50E-6BF378E83A70",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "64CCA458-1F7F-44ED-ACD5-E9355B112194",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_2hr2_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FD9EACF0-ECE5-40DD-8280-41707A637E9E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr528-6m_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7B7870B9-F1CF-4503-A64C-6258FFB9D78D",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr528-6m_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "81355370-BE69-434F-ABAC-8611F9909E46",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7319A333-EAA2-4ED2-A814-1AAEDFAC4E04",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AB16A0BE-5AF3-4168-B755-D023E497A35F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B490BBD4-458F-4077-8404-9208499226E7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "09743616-31C9-4E47-8A4A-B15D76204BE7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "87B35693-9D07-4507-8070-43B8F756F772",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4A806691-3F4B-46AA-9718-2F6BF0FD3D7A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B05DE63D-186B-46CC-B3CE-66923F290B6B",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C97B2B53-F40E-4FB1-B3BA-5D0E0F8501F0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xr552-12m_2hr2_l3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EF61A53B-E4AD-4379-B053-1A25FDF65BD0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xr552-12m_2hr2_l3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BA9921B1-38FD-4404-9986-3023C577FE5C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.",
      },
      {
         lang: "es",
         value: "Los dispositivos afectados no manejan adecuadamente la renegociación de los parámetros SSL/TLS. Esto podría permitir a un atacante remoto no autenticado eludir la prevención de fuerza bruta de TCP y provocar una condición de denegación de servicio mientras dure el ataque",
      },
   ],
   id: "CVE-2022-36324",
   lastModified: "2024-11-21T07:12:47.307",
   metrics: {
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "productcert@siemens.com",
            type: "Secondary",
         },
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2022-08-10T12:15:12.930",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Mitigation",
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Mitigation",
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-710008.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-770",
            },
         ],
         source: "productcert@siemens.com",
         type: "Secondary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-770",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

Vulnerability from fkie_nvd
Published
2021-01-12 21:15
Modified
2024-11-21 05:06
Severity ?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.
Impacted products
Vendor Product Version
siemens scalance_x200-4pirt_firmware *
siemens scalance_x200-4pirt -
siemens scalance_x201-3pirt_firmware *
siemens scalance_x201-3pirt -
siemens scalance_x202-2irt_firmware *
siemens scalance_x202-2irt -
siemens scalance_x202-2pirt_firmware *
siemens scalance_x202-2pirt -
siemens scalance_x202-2pirt_siplus_net_firmware *
siemens scalance_x202-2pirt_siplus_net -
siemens scalance_x204irt_firmware *
siemens scalance_x204irt -
siemens scalance_x307-3_firmware *
siemens scalance_x307-3 -
siemens scalance_x307-3ld_firmware *
siemens scalance_x307-3ld -
siemens scalance_x308-2_firmware *
siemens scalance_x308-2 -
siemens scalance_x308-2ld_firmware *
siemens scalance_x308-2ld -
siemens scalance_x308-2lh_firmware *
siemens scalance_x308-2lh -
siemens scalance_x308-2lh\+_firmware *
siemens scalance_x308-2lh\+ -
siemens scalance_x308-2m_firmware *
siemens scalance_x308-2m -
siemens scalance_x308-2m_ts_firmware *
siemens scalance_x308-2m_ts -
siemens scalance_x310_firmware *
siemens scalance_x310 -
siemens scalance_x310fe_firmware *
siemens scalance_x310fe -
siemens scalance_x320-1fe_firmware *
siemens scalance_x320-1fe -
siemens scalance_x320-3ldfe_firmware *
siemens scalance_x320-3ldfe -
siemens scalance_xb205-3_firmware *
siemens scalance_xb205-3 -
siemens scalance_xb205-3ld_firmware *
siemens scalance_xb205-3ld -
siemens scalance_xb208_firmware *
siemens scalance_xb208 -
siemens scalance_xb213-3_firmware *
siemens scalance_xb213-3 -
siemens scalance_xb213-3ld_firmware *
siemens scalance_xb213-3ld -
siemens scalance_xb216_firmware *
siemens scalance_xb216 -
siemens scalance_xc206-2_firmware *
siemens scalance_xc206-2 -
siemens scalance_xc206-2g_poe__firmware *
siemens scalance_xc206-2g_poe_ -
siemens scalance_xc206-2g_poe_eec_firmware *
siemens scalance_xc206-2g_poe_eec -
siemens scalance_xc206-2sfp_firmware *
siemens scalance_xc206-2sfp -
siemens scalance_xc206-2sfp_eec_firmware *
siemens scalance_xc206-2sfp_eec -
siemens scalance_xc206-2sfp_g_firmware *
siemens scalance_xc206-2sfp_g -
siemens scalance_xc206-2sfp_g_\(e\/ip\)_firmware *
siemens scalance_xc206-2sfp_g_\(e\/ip\) -
siemens scalance_xc206-2sfp_g_eec_firmware *
siemens scalance_xc206-2sfp_g_eec -
siemens scalance_xc208_firmware *
siemens scalance_xc208 -
siemens scalance_xc208eec_firmware *
siemens scalance_xc208eec -
siemens scalance_xc208g_firmware *
siemens scalance_xc208g -
siemens scalance_xc208g_\(e\/ip\)_firmware *
siemens scalance_xc208g_\(e\/ip\) -
siemens scalance_xc208g_eec_firmware *
siemens scalance_xc208g_eec -
siemens scalance_xc208g_poe_firmware *
siemens scalance_xc208g_poe -
siemens scalance_xc216_firmware *
siemens scalance_xc216 -
siemens scalance_xc216-4c_firmware *
siemens scalance_xc216-4c -
siemens scalance_xc216-4c_g_firmware *
siemens scalance_xc216-4c_g -
siemens scalance_xc216-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc216-4c_g_\(e\/ip\) -
siemens scalance_xc216-4c_g_eec_firmware *
siemens scalance_xc216-4c_g_eec -
siemens scalance_xc216eec_firmware *
siemens scalance_xc216eec -
siemens scalance_xc224-4c_g__firmware *
siemens scalance_xc224-4c_g_ -
siemens scalance_xc224-4c_g_\(e\/ip\)_firmware *
siemens scalance_xc224-4c_g_\(e\/ip\) -
siemens scalance_xc224-4c_g_eec_firmware *
siemens scalance_xc224-4c_g_eec -
siemens scalance_xc224__firmware *
siemens scalance_xc224_ -
siemens scalance_xf201-3p_irt_firmware *
siemens scalance_xf201-3p_irt -
siemens scalance_xf202-2p_irt_firmware *
siemens scalance_xf202-2p_irt -
siemens scalance_xf204_firmware *
siemens scalance_xf204 -
siemens scalance_xf204-2_firmware *
siemens scalance_xf204-2 -
siemens scalance_xf204-2ba_dna_firmware *
siemens scalance_xf204-2ba_dna -
siemens scalance_xf204-2ba_irt_firmware *
siemens scalance_xf204-2ba_irt -
siemens scalance_xf204_dna_firmware *
siemens scalance_xf204_dna -
siemens scalance_xf204irt_firmware *
siemens scalance_xf204irt -
siemens scalance_xf206-1_firmware *
siemens scalance_xf206-1 -
siemens scalance_xf208_firmware *
siemens scalance_xf208 -
siemens scalance_xp208_firmware *
siemens scalance_xp208 -
siemens scalance_xp208_\(eip\)_firmware *
siemens scalance_xp208_\(eip\) -
siemens scalance_xp208eec_firmware *
siemens scalance_xp208eec -
siemens scalance_xp208poe_eec_firmware *
siemens scalance_xp208poe_eec -
siemens scalance_xp216_firmware *
siemens scalance_xp216 -
siemens scalance_xp216_\(eip\)_firmware *
siemens scalance_xp216_\(eip\) -
siemens scalance_xp216eec_firmware *
siemens scalance_xp216eec -
siemens scalance_xp216poe_eec_firmware *
siemens scalance_xp216poe_eec -



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x200-4pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "43B261ED-08C4-4A0D-8BAC-221006AB6F93",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x200-4pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FDCB432-1AD0-4BF1-839F-8091D9871831",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x201-3pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "53F56390-77CB-42D5-A603-5FB29EE5DAA5",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x201-3pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "47498977-D642-4864-BB94-4CE077EDEB82",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "666FACCE-89EB-4E5D-A718-F1D4945F7DF4",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "A8B1D979-038F-42F4-AB7D-E0664D051B4E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B79AD48F-2B99-4BE5-B3D7-440E2D3BC699",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7819B14-7E93-4D0F-AAD5-049BE3B36D07",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x202-2pirt_siplus_net_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CD18B3BE-E98D-46D1-AA10-89EB89BAFFEB",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x202-2pirt_siplus_net:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DABC3436-E04E-4B6C-9EF4-47B08C57B166",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C94D093-9D17-47C9-A7F6-28FF241BF874",
                     versionEndExcluding: "5.5.0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "9676DB10-982D-445F-9779-B39AE720AF2F",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "48D3EB09-6069-4289-A61E-C15B044EA2E2",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7737F0C2-43FC-4330-88F2-9B08BA5B35D7",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "40A1A5F9-4971-4E9D-BBE7-5A0357C56213",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FE1909FA-C8C6-46BE-83C6-2635D36FE69B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8F53C74B-2154-417E-ACFE-01F0BACD3F15",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6DDBD94D-5312-4A54-AF76-D9DF791C0292",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D76A2268-5397-466C-98B5-01B46B4840A1",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "85153EED-C677-495D-A6BB-72365DE1ED3F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "2F8888A7-3285-4ACA-A5AD-2B0578050C4C",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "AC54911E-C432-48FA-9551-9644422FFE14",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A2C12934-E79C-41A4-B023-BADD7D68CB55",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFCCB68C-A58D-4543-A11F-721B01FFBBA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D288227C-69C1-4248-AB4A-51F44A41FDEA",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FE3716E-1C0A-4B72-809A-8318E5853FB1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8FB34E83-83A3-45C3-B040-D8910971D439",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "91EDD23A-1DBD-4117-9396-89ADBC705B3A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC54880F-CBF4-4772-A4FB-B07D97287D44",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "AF07B014-1BA3-477E-A405-5DB35F68126A",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "80502856-7617-4ED9-A103-681021131EE0",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7178F049-8E48-4175-AE8C-818128205D33",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B9F9F101-6042-4D11-98CE-16A996023B38",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb205-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7327CDF-EF0D-443B-A822-D69669C3B80C",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb205-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "18DC9125-FC41-4BAB-9638-C42DEF40235B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C7DDB0D1-21AC-43AC-9DDF-C6D89D3F1AA1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "5C19D54A-8070-4EC6-9B30-B1B04A8BDABD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "7FAB9D2E-94BC-4C90-ADF3-27FB34FC23A9",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "1FF67A06-D93B-4E4E-A639-29E0E49654FE",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb213-3ld_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3003D9C7-A979-4289-AADD-190A55434F31",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb213-3ld:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0EFCF766-E1D3-4BD5-A70C-3A824B7D45DF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xb216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1A0E6F26-15BE-4586-8ACD-1DAF9492A7D7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xb216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "72EC10EB-0679-4AFE-ABC3-C58A68A0C4DD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED3A29A7-F1B0-4A2C-AB63-6E4A57A6864D",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "49C5CBD8-9799-4EBA-8297-EAE04F43DDD5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4EFEB827-71F1-4DDF-B156-949AF8E39A34",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39310380-7D17-46C5-B91A-DFDF602D56A5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2g_poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "1B191270-07F7-4173-833A-7F4929F643BF",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2g_poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0C21EC27-F0A8-4DCA-88AD-92D07477B5AD",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC590D4F-C818-4CD8-A8E9-E2A951E5D768",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "804E37AB-9EE4-4931-A874-4FBD427252D1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6AABE919-D289-43CB-A285-3212E630B313",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CC286693-55D6-4949-8164-262EB6C022C9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CA08C94B-BE44-49D1-AB10-7512F65D6DF1",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "BC7B235D-0141-46E5-9057-2203555AE58A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "578CE1DA-BA53-4EA5-AB2D-4670321DDF81",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "CB6B6ED1-7057-4240-B1C9-660173BF1A6A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc206-2sfp_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DFEA3FDE-9575-4E9B-BE5F-6BEB005381D8",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc206-2sfp_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6F7D1CCD-4DFD-4037-9BDC-65466D639456",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "5FC77B9E-9081-44E0-82AF-0411940B0684",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E6A2B708-309D-4BE5-BAEE-7AE035A2ADD1",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED6AD6D3-75AC-4C7E-9471-8288FB7AABA4",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B6550B2D-4B8E-414C-B4CB-7B12D6D4EA4A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "D51DCE8E-2E29-4969-A26B-A1A10220CA83",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8E922B78-7951-4115-8985-D824F6DDE41B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "F4F3FB17-F6E8-4BB1-B910-C9F03B936C32",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "62852B4B-AF5A-4967-AFC2-14CEC2F6972C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "DF97E576-EBD2-4F1F-BE8F-4254D134565B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "9CCF0CEF-2E48-472E-9BDE-6E63F4CEA467",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc208g_poe_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0378595B-379F-4775-B5D9-CCAC4042F635",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc208g_poe:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "585424EB-F9AB-45FB-B5C5-78FE45E3341A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8A03BBB2-9650-4C8A-A137-0C8AC6CDAD66",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4ABC0D8D-4F32-487F-835C-DADAB647EC21",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BCD1CF2-F24A-4C47-9C88-340E67C77871",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7668BC0B-A47A-4E05-9933-51CD43F3B7BA",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4DAD438B-DABE-4B9A-9CDB-9BAC16313F0F",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "78645734-50C1-4331-9FC4-AC8A8679B6AF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E1F3FE19-E279-4280-8F67-0C085B083E10",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "22B8B758-9781-474E-93C3-17DDDF263CC2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "ED7BCCB2-CE77-45A3-A6E1-D591894847C7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "323CEAEA-8122-43A5-BB87-97C7133FF510",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7C43419-B7AA-40EB-A40D-840F975BE2EC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6BE498F8-A9D8-4A92-90CE-21BA30234947",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "580A5BD5-2E8E-4801-BFE8-7476088F4214",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "E7806CF9-4DA5-4090-84BD-D098C5FB1178",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_\\(e\\/ip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FFAC6598-DDAC-4873-9545-39B0EF21D478",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_\\(e\\/ip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "EE4E3630-DB15-46EA-B320-E4E457240B9F",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224-4c_g_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "561064E3-FC05-4028-B75D-4D2519FEFD24",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224-4c_g_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0B0A02C9-A7CB-4CB3-B5DC-5FEE20A59208",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xc224__firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4303ED83-6610-458F-BEE9-B99BA31DD962",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xc224_:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "39AB9EB3-0F05-41C2-A32F-27B6D0C9C039",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "475E5069-C120-4D49-AB9D-D3C3F94BD093",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "41614C70-97B4-44C8-A441-530A413A26F9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "274E5C49-CA32-44D2-A864-C99A48CAA869",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "6751FB7D-C72C-4321-B535-5880FE696FC3",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8CD13707-1164-415E-9083-7946D151F1FC",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "0F1AE867-67B4-4871-BF56-88017533A737",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3A09FF2D-F369-47B5-AEE4-A862BEDD9851",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "69285324-4C0B-4BDC-B60D-F653679DD52D",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "0BBC3005-41D0-4BA0-A146-E48E612CAF58",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FAF28152-D6CA-4D20-BDF1-1EF4B7D10429",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "85B917B7-81E1-4419-B493-1D321027017E",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "99E6AFAA-B903-47BB-B0F3-7650B039C0FB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204_dna_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "FCBEE10A-7E96-4239-AE6C-5FA9A6A32196",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204_dna:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "70D62F13-AD59-435E-851A-87A0A6E2FA3B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "42288C48-A2AA-4AA1-B5A2-F83C5A3689AE",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "57E5489B-277A-4D02-B4AB-4DB65969EED2",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "CFCDC84E-0695-409A-844B-D24024CC33F2",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B40D2EB-5C69-47FA-801B-DC48407D418C",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "A1DB6C03-71BF-4359-834B-384E78910E64",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "8082D4C1-C59E-43B6-B11F-C814ACD00321",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "24C7FB09-D247-48F0-B87C-6A478BDC0A5A",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "34349AEF-170F-432F-8D64-347F08536D3A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "17BD41C2-2398-4A03-9C5F-43AEF424261E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "EACF7493-4FE6-4902-9EE7-76F1B4AB118A",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "2B313A4C-D3E7-4964-BA51-3401546B36C5",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp208poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3237051D-0342-4DB8-B4A1-40A3B33A67BB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp208poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D6E888EA-73A7-42B8-A617-621CF192F2A9",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "4969C410-25DF-4BFA-9125-53D63B33691B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "67E4D039-5BF8-469B-A6FE-A391A6D1BDA4",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216_\\(eip\\)_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B4A2ED6E-6632-4DD9-A359-73EB28BB306B",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216_\\(eip\\):-:*:*:*:*:*:*:*",
                     matchCriteriaId: "33D044BD-12AD-42C9-B01C-957BEC6C6790",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "3B54DF8C-BB5A-46AF-862D-DC8E984A05AB",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "12512EC4-FB7D-420F-9A8A-547562BE1B49",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:scalance_xp216poe_eec_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "6FF74FFD-81C8-4E63-8B7B-AEBD98AB34F7",
                     versionEndExcluding: "5.2.5",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:scalance_xp216poe_eec:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C9BACE8C-6C69-4BC4-8F5B-1C74FA7EB339",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). The webserver of the affected devices contains a vulnerability that may lead to a heap overflow condition. An attacker could cause this condition on the webserver by sending specially crafted requests. This could stop the webserver temporarily.",
      },
      {
         lang: "es",
         value: "Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluyendo las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.2.5), SCALANCE X-200IRT switch family (incluyendo las variantes SIPLUS NET) (Todas las versiones anteriores a la versión V5.5.0), familia de switches SCALANCE X-300 (incluyendo Variantes X408 y SIPLUS NET) (Todas las versiones anteriores a la versión V4.1.0). El servidor web de los dispositivos afectados contiene una vulnerabilidad que puede conllevar una condición de desbordamiento de la pila. Un atacante podría causar esta condición en el servidor web enviando peticiones especialmente diseñadas. Esto podría detener el servidor web temporalmente",
      },
   ],
   id: "CVE-2020-15800",
   lastModified: "2024-11-21T05:06:12.450",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "MEDIUM",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "COMPLETE",
               baseScore: 9.3,
               confidentialityImpact: "COMPLETE",
               integrityImpact: "COMPLETE",
               vectorString: "AV:N/AC:M/Au:N/C:C/I:C/A:C",
               version: "2.0",
            },
            exploitabilityScore: 8.6,
            impactScore: 10,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 9.8,
               baseSeverity: "CRITICAL",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
               version: "3.1",
            },
            exploitabilityScore: 3.9,
            impactScore: 5.9,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2021-01-12T21:15:16.480",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-139628.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-122",
            },
         ],
         source: "productcert@siemens.com",
         type: "Primary",
      },
      {
         description: [
            {
               lang: "en",
               value: "CWE-787",
            },
         ],
         source: "nvd@nist.gov",
         type: "Secondary",
      },
   ],
}