cve-2019-10936
Vulnerability from cvelistv5
Published
2019-10-10 00:00
Modified
2024-08-04 22:40
Severity ?
EPSS score ?
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "dk_standard_ethernet_controller_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200_firmware", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ek-ertec_200p_firmware", "vendor": "siemens", "versions": [ { "lessThan": "4.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_cfu_pa", "vendor": "siemens", "versions": [ { "lessThan": "v1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200ecopn_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et200s_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200al_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200m_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200mp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200pro_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200s_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_et_200sp_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_hmi_comfort_outdoor_panels", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0", "vendor": "siemens", "versions": [ { "lessThan": "v4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_profinet_driver", "vendor": "siemens", "versions": [ { "lessThan": "v2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_314_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_315f-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v3.2.17", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_412-2_pn", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_414-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThan": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_cpu_416-3_pn\\/dp", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_h_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "v6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-400_pn\\/dp_v6_firmware", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-410_cpu_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v8.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1200_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_cpu", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_s7-1500_controller", "vendor": "siemens", "versions": [ { "lessThan": "v2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cp51m1_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_tdc_cpu555_firmware", "vendor": "siemens", "versions": [ { "lessThan": "v1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "simatic_winac_rtx_\\(f\\)_2010", "vendor": "siemens", "versions": [ { "lessThan": "v2010_sp3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcm", "vendor": "siemens", "versions": [ { "lessThan": "v1.5_hf1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_dcp", "vendor": "siemens", "versions": [ { "lessThan": "v1.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g110m", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g120", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_sp10_hf5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g130", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_g150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gh150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gl150", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_gm150", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s110", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_s120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sl150", "vendor": "siemens", "versions": [ { "lessThan": "v4.7_hf33", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinamics_sm120", "vendor": "siemens", "versions": [ { "lessThanOrEqual": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_828d", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "sinumerik_840d_sl", "vendor": "siemens", "versions": [ { "lessThan": "v4.8_sp6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "siplus_s7-300_cpu_314", "vendor": "siemens", "versions": [ { "lessThan": "v3.3.17", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2019-10936", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T14:36:59.481395Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T15:59:12.602Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.253Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.6 Patch 01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.9", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M V4.7 PN Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP10 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c 4.8" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF33" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 Control Unit", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP5" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP6" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.4.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.3", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:55.957Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10936", "datePublished": "2019-10-10T00:00:00", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.253Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-25622
Vulnerability from cvelistv5
Published
2022-04-12 00:00
Modified
2025-01-14 10:26
Severity ?
EPSS score ?
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.
This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC CFU DIQ |
Version: 0 < V2.0.0 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:42:50.341Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 MF HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.3", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/MF Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V10.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "lessThan": "V1.5 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G115D", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7 SP14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210 (6SL5...)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF18", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90", "vendor": "Siemens", "versions": [ { "lessThan": "V1.04.04", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4300 CIM4310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2025-01-14T10:26:55.984Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-25622", "datePublished": "2022-04-12T00:00:00", "dateReserved": "2022-02-21T00:00:00", "dateUpdated": "2025-01-14T10:26:55.984Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28400
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-12-10 13:53
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "status": "affected", "version": "0" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p", "vendor": "siemens", "versions": [ { "lessThan": "v4.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ruggedcom_rm1224", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m804pb", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_a", "vendor": "seimens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816_1_adsl_router_annex_a", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816-1_adsl-router_annex_b", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m826-2_shdsl-router", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_2", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_3", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_evdo", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_rok", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_eu", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_nam", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_s615", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w700_ieee_802.11n_family", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1748_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_eec_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2ia_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x200_4p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x202_2p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_202_2p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x204_2", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2fm", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld_ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2020-28400", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T18:59:11.953107Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-24T18:07:44.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3 3G-Router (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IE/PB-LINK", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Power Line Booster PLB, Base Module", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:22.763Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28400", "datePublished": "2021-07-13T11:02:49", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-12-10T13:53:22.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2022-04-12 09:15
Modified
2024-11-21 06:52
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.
This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-446448.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-446448.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cfu_diq_firmware | * | |
siemens | simatic_cfu_diq | - | |
siemens | simatic_cfu_pa_firmware | * | |
siemens | simatic_cfu_pa | - | |
siemens | simatic_s7-300_cpu_firmware | * | |
siemens | simatic_s7-300_cpu | - | |
siemens | simatic_s7-400h_v6_firmware | * | |
siemens | simatic_s7-400h_v6 | - | |
siemens | simatic_s7-400_pn\/dp_v7_firmware | * | |
siemens | simatic_s7-400_pn\/dp_v7 | - | |
siemens | simatic_s7-410_v8_firmware | * | |
siemens | simatic_s7-410_v8 | - | |
siemens | simatic_s7-410_v10_firmware | * | |
siemens | simatic_s7-410_v10 | - | |
siemens | simatic_s7-1500_cpu_firmware | * | |
siemens | simatic_s7-1500_cpu | - | |
siemens | simatic_tdc_cp51m1_firmware | * | |
siemens | simatic_tdc_cp51m1 | - | |
siemens | simatic_tdc_cpu555_firmware | * | |
siemens | simatic_tdc_cpu555 | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx | - | |
siemens | simit_simulation_platform | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CF0CF4BB-3200-4942-ADA2-120D348E03A4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*", "matchCriteriaId": "AF942F59-C13F-40FC-9601-2B4202677CC4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5119182-CB31-466A-AB0F-7956C8B45AE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4872DF2-8C81-45BA-A606-99D0A75464AC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6668A57C-BC46-4008-B174-9E557946ACA2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC44664E-830D-4122-A97A-1AFA61F5BBB5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18E1CA5D-3D7D-49D0-A417-235E2AF6075C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70A009DD-9D8A-4FF3-B65C-D1AF477D5CB5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F240847-0ADC-475C-BDDF-6483A8FF5602", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1ED5EE9B-B05A-4D2A-9FC6-0519E020FFB8", "versionEndExcluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "01048F7F-9C5B-47C0-AE16-321FCA670F3D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3E2689E6-A204-4744-827E-EEFB11B7C334", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*", "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9C7D4A-F989-4B01-8FFD-5B5859F42D43", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2E721F4E-2F84-496D-938D-A27F3E53E543", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*", "matchCriteriaId": "7902D452-4DA8-420E-BD33-5FC112C2F5BE", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, Acoplador SIMATIC PN/MF, Acoplador SIMATIC PN/PN, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 relacionadas y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V10 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V8 (incl. variantes SIPLUS). variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX, SIMIT Simulation Platform, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. variantes SIPLUS), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. variantes SIPLUS), SIMATIC S120 (incl. variantes SIPLUS). variantes SIPLUS), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. La pila PROFINET (PNIO), cuando se integra con la pila IP de Interniche, maneja incorrectamente los recursos internos para los segmentos TCP en los que la longitud m\u00ednima del TCP-Header es inferior a la definida. Esto podr\u00eda permitir a un atacante crear una condici\u00f3n de denegaci\u00f3n de servicio para los servicios TCP en los dispositivos afectados mediante el env\u00edo de segmentos TCP especialmente dise\u00f1ados" } ], "id": "CVE-2022-25622", "lastModified": "2024-11-21T06:52:27.700", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-04-12T09:15:14.483", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-10-10 14:15
Modified
2024-11-21 04:20
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-473245.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-473245.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200_firmware | * | |
siemens | ek-ertec_200 | - | |
siemens | ek-ertec_200p_firmware | * | |
siemens | ek-ertec_200p_firmware | 4.6 | |
siemens | ek-ertec_200p | - | |
siemens | simatic_cfu_pa_firmware | * | |
siemens | simatic_cfu_pa | - | |
siemens | simatic_et_200al_firmware | * | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_im_155-5_pn_ba_firmware | * | |
siemens | simatic_et_200mp_im_155-5_pn_ba | - | |
siemens | simatic_et_200mp_im_155-5_pn_hf_firmware | * | |
siemens | simatic_et_200mp_im_155-5_pn_hf | - | |
siemens | simatic_et_200mp_im_155-5_pn_st_firmware | * | |
siemens | simatic_et_200mp_im_155-5_pn_st | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_im_155-6_pn_ba_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_ba | - | |
siemens | simatic_et_200sp_im_155-6_pn_ha_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_ha | - | |
siemens | simatic_et_200sp_im_155-6_pn_hf_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_hf | - | |
siemens | simatic_et_200sp_im_155-6_pn_hs_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_hs | - | |
siemens | simatic_et_200sp_im_155-6_pn_st_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn_st | - | |
siemens | simatic_et_200sp_im_155-6_pn\/2_hf_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn\/2_hf | - | |
siemens | simatic_et_200sp_im_155-6_pn\/3_hf_firmware | * | |
siemens | simatic_et_200sp_im_155-6_pn\/3_hf | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200pro_firmware | * | |
siemens | simatic_et_200pro | - | |
siemens | simatic_hmi_comfort_outdoor_panels_7\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_7\" | - | |
siemens | simatic_hmi_comfort_outdoor_panels_15\"_firmware | * | |
siemens | simatic_hmi_comfort_outdoor_panels_15\" | - | |
siemens | simatic_hmi_comfort_panels_4\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_4\" | - | |
siemens | simatic_hmi_comfort_panels_22\"_firmware | * | |
siemens | simatic_hmi_comfort_panels_22\" | - | |
siemens | simatic_hmi_ktp_mobile_panels_firmware | * | |
siemens | simatic_hmi_ktp_mobile_panels | - | |
siemens | simatic_pn\/pn_coupler_firmware | * | |
siemens | simatic_pn\/pn_coupler | - | |
siemens | simatic_profinet_driver_firmware | * | |
siemens | simatic_profinet_driver | - | |
siemens | simatic_s7-1200_cpu_firmware | * | |
siemens | simatic_s7-1200_cpu | - | |
siemens | simatic_s7-1200_cpu_1211c_firmware | * | |
siemens | simatic_s7-1200_cpu_1211c | - | |
siemens | simatic_s7-1200_cpu_1212c_firmware | * | |
siemens | simatic_s7-1200_cpu_1212c | - | |
siemens | simatic_s7-1200_cpu_1214c_firmware | * | |
siemens | simatic_s7-1200_cpu_1214c | - | |
siemens | simatic_s7-1500_cpu_firmware | * | |
siemens | simatic_s7-1500_cpu | - | |
siemens | simatic_s7-1500s_cpu_firmware | * | |
siemens | simatic_s7-1500s_cpu | - | |
siemens | simatic_s7-1500t_cpu_firmware | * | |
siemens | simatic_s7-1500t_cpu | - | |
siemens | simatic_s7-1500_cpu_1518_firmware | * | |
siemens | simatic_s7-1500_cpu_1518 | - | |
siemens | simatic_s7-1500_cpu_1511c_firmware | * | |
siemens | simatic_s7-1500_cpu_1511c | - | |
siemens | simatic_s7-1500_cpu_1512c_firmware | * | |
siemens | simatic_s7-1500_cpu_1512c | - | |
siemens | simatic_s7-300_cpu_firmware | * | |
siemens | simatic_s7-300_cpu | - | |
siemens | simatic_s7-300_cpu_312_ifm_firmware | * | |
siemens | simatic_s7-300_cpu_312_ifm | - | |
siemens | simatic_s7-300_cpu_313_firmware | * | |
siemens | simatic_s7-300_cpu_313 | - | |
siemens | simatic_s7-300_cpu_314_firmware | * | |
siemens | simatic_s7-300_cpu_314 | - | |
siemens | simatic_s7-300_cpu_314_ifm_firmware | * | |
siemens | simatic_s7-300_cpu_314_ifm | - | |
siemens | simatic_s7-300_cpu_315_firmware | * | |
siemens | simatic_s7-300_cpu_315 | - | |
siemens | simatic_s7-300_cpu_315-2_dp_firmware | * | |
siemens | simatic_s7-300_cpu_315-2_dp | - | |
siemens | simatic_s7-300_cpu_316-2_dp_firmware | * | |
siemens | simatic_s7-300_cpu_316-2_dp | - | |
siemens | simatic_s7-300_cpu_318-2_firmware | * | |
siemens | simatic_s7-300_cpu_318-2 | - | |
siemens | simatic_s7-400_pn_v7_firmware | * | |
siemens | simatic_s7-400_pn_v7 | - | |
siemens | simatic_s7-400_dp_v7_firmware | * | |
siemens | simatic_s7-400_dp_v7 | - | |
siemens | simatic_s7-400_v6_firmware | * | |
siemens | simatic_s7-400_v6 | - | |
siemens | simatic_s7-400h_v6_firmware | * | |
siemens | simatic_s7-400h_v6 | - | |
siemens | simatic_s7-410_v8_firmware | * | |
siemens | simatic_s7-410_v8 | - | |
siemens | simatic_winac_rtx_\(f\)_firmware | * | |
siemens | simatic_winac_rtx_\(f\)_firmware | 2010 | |
siemens | simatic_winac_rtx_\(f\)_2010 | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.5 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120_firmware | * | |
siemens | sinamics_g120_firmware | 4.7 | |
siemens | sinamics_g120 | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 5.2 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150_firmware | 5.2 | |
siemens | sinamics_g150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.8 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_s110_firmware | * | |
siemens | sinamics_s110 | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 5.2 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 5.2 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.7 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | - | |
siemens | sinamics_sm120 | - | |
siemens | sinumerik_828d | * | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_828d | 4.8 | |
siemens | sinumerik_840d_sl | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E19343EA-5ECA-4263-A568-DAEA04425F86", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "70D5CDF4-A134-402E-A4E9-4BBA19082397", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*", "matchCriteriaId": "B47CF3BB-08E4-4B86-B793-8253C172D846", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2773F4B7-095E-4A33-93F2-765FA58B828C", "versionEndExcluding": "4.6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*", "matchCriteriaId": "9E7753EE-DF23-4838-B3B4-7C43C550519C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ABA8C0E5-E6AA-4BF2-925F-0041C382A416", "versionEndExcluding": "1.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "24E01824-4942-4400-A8C2-43A5772C2968", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B4458E08-9864-452E-B95E-A46C5600D488", "versionEndExcluding": "4.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "9AF349D2-2560-4C60-8729-4B6CCDC52347", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "00743200-D240-4CBC-8652-555F5E89B042", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB9BFB03-D366-4F23-9477-D6133BD021CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACDF9AF3-DDB9-41A8-90C5-2A95A51D5EDE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*", "matchCriteriaId": "4B48C0A4-072A-4744-94A5-FC4741F4A029", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8A1327FC-E785-4AA7-BC73-CC61CEED832D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C0300D2-1A87-4F61-9444-C1D23E3E6033", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "17B7ED41-6AC7-4D34-A94E-61AECFA088EA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*", "matchCriteriaId": "34131306-1591-42B3-B235-4265F918CBDA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67DAE64A-6E78-452E-9812-242769378ED8", "versionEndExcluding": "4.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "527AE806-5C00-4C44-940F-88032AD8120D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AAAA8667-C792-45E4-AE5E-C194B5B76366", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*", "matchCriteriaId": "455EC7E5-236B-43E6-86E7-702FAFCCCB15", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "918CBE10-D912-446B-B8B3-843B0089CB7A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*", "matchCriteriaId": "1DB6FAE7-8598-4673-83A9-7A838BB207C5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6269D1CC-FF57-409F-8284-C95FF4DCEF25", "versionEndExcluding": "4.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "2CBAACFE-CD21-4FAC-9262-1A7F325D6E40", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3FA7253F-17B9-411B-B4C9-FE51DF0DE44D", "versionEndExcluding": "4.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*", "matchCriteriaId": "DCCAFEF7-CA0C-4F20-B98E-DBB8365F1CCF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5F14E991-8DF6-4221-A9BF-E13EEF211220", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE84D161-BA23-422A-8959-CF047834A631", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6230347-9AAE-424F-A46F-4A714BA0823D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A1A44BC-15CC-4CC1-A9D0-4B04233B80CE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "87B14F05-4D54-420F-8393-4AB27EF6A7D1", "versionEndExcluding": "4.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "matchCriteriaId": "49FB85F8-7D45-433E-805B-360725F2980C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05248152-94EB-4978-98A7-B1A393CA1F03", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", "matchCriteriaId": "526493E9-EF74-4836-9A8F-134B625035AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BA63AED-84E4-4F92-A4D4-0713E7F65C4A", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "F2B63726-10CE-46AB-ADBA-A511E770E162", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D81B519-6FE9-405C-8BB1-57D14AF531E5", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "84E0444D-01E0-4F7A-81A0-314C0F7FA623", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B980BB8C-9AFE-45E4-A4D4-AB555B234059", "versionEndExcluding": "4.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BD6FB801-AE4C-4EDF-96CC-33A4CD51165A", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "01048F7F-9C5B-47C0-AE16-321FCA670F3D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D5DE5B3D-13B1-4684-8859-C3FB34FE50CF", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "B82EADBC-AECE-45B4-AF95-6F0D84966E67", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF5E4914-A5EA-451C-9FAF-751B74B8BC69", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "4BE2F683-2A24-4152-9A07-00B0117C5F12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B6777DC-80B5-4B36-B9AA-DA764C8016F7", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*", "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55490E3D-616D-4D21-BAC2-29A51CB067E9", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*", "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45303F50-046B-4621-AC6D-2B6E17D948C3", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C87674A8-B518-4910-B03D-FFF4D5A7B627", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*", "matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7B0C6327-7BF6-4B96-82A8-D750007869EE", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*", "matchCriteriaId": "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E6E900F-63C1-4E50-9DCD-26CE760E5275", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F2F0659-CD37-4AA9-B7D5-44639515533C", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", "matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*", "matchCriteriaId": "8BE7963C-7AFF-495B-9F0B-28FB393443FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F2A0C75-E360-4E3D-85DA-878E39054E26", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3962681-E32E-4BD1-8C71-8768248691D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "488F0774-43DA-455D-905C-C514A0192260", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F103C351-99C9-4F7D-B69A-D8A876F57504", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "644AD6A8-AEDE-4F1C-92F8-836877A81310", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA99549B-5E95-445A-A95B-1CDA7014686B", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "FF58C652-E74D-4B57-A7C5-08D7446863D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72F7B870-35A1-4900-8104-1303F291E29A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7A4C79A5-96BB-4ADB-B28A-C9C48B195F49", "versionEndExcluding": "6.0.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "A6445275-2AEF-4285-BE7A-67F20182481C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EE93A33C-7007-4908-868A-4FBE4D073E57", "versionEndExcluding": "6.0.9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "63EA1886-A72E-48A7-B99F-C236BF6992FA", "versionEndExcluding": "8.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D03BD73-51ED-42E0-A552-C32BB7A935B2", "versionEndExcluding": "2010", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*", "matchCriteriaId": "7151A19C-0AE5-4F66-9E3D-8BF675A8430C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "E6034789-ABD1-4035-8378-F0BA7157B087", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B", "versionEndExcluding": "1.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*", "matchCriteriaId": "F2F99FFB-C312-4080-9580-84AFB7C9FA09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "83803F1C-4842-43BB-B903-C2E91FF7DC08", "versionEndExcluding": "1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*", "matchCriteriaId": "61A60DCE-384B-43A4-A669-973FB8ECA932", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "AD0515D7-829B-4591-95D9-94C3982FD727", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "255A153A-A6A0-46A4-A7CF-01D0D09761C7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "243FFEA3-7193-45EA-B865-E9CA1D6656FE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*", "matchCriteriaId": "6218802E-D3B1-4197-A6B5-7343A50F7D88", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BF989EE-CD8D-450D-90F6-FD15F00B59B9", "versionEndExcluding": "5.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*", "matchCriteriaId": "EFFDE2CB-684D-4ECE-A104-F355254A46B9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30E52510-9306-42B8-A517-A6BBD34B8B9D", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "58A71910-E54F-426B-BAB1-260AEFD8EF6E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "28DB0BC6-E60A-4798-80DC-125EF25B3A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*", "matchCriteriaId": "328F0192-B34D-481C-8964-226317439966", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "C7936CF6-DC07-4550-9FEC-823A2F49096D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*", "matchCriteriaId": "BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*", "matchCriteriaId": "BDBAEDBC-6A76-495D-9BC7-BA687F32EE40", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*", "matchCriteriaId": "45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*", "matchCriteriaId": "48EE5859-5450-4078-94E7-E525B999A837", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*", "matchCriteriaId": "9FFC86D6-F312-4097-91A6-79C78502323F", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Kits de desarrollo/evaluaci\u00f3n para PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS), SIMATIC ET200AL, SIMATIC ET200M (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incl. variantes SIPLUS) SIPLUS), SIMATIC ET200S (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incl. variantes SIPLUS). SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" a 22\" (incl. variantes SIPLUS), paneles m\u00f3viles SIMATIC HMI KTP, acoplador SIMATIC PN/PN (incl. variantes SIPLUS NET), driver SIMATIC PROFINET, familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-1500 (incl. variantes SIPLUS). CPUs ET200 y variantes SIPLUS), SIMATIC S7-1500 Software Controller, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS). SIPLUS), familia de CPU SIMATIC S7-410 V8 (incl. variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4. 7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. variantes SIPLUS), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4. 7, SINAMICS GL150 V4.7, SINAMICS GM150 V4.7, SINAMICS S110, SINAMICS S120 V4.7 (incluidas las variantes SIPLUS), SINAMICS S150, SINAMICS SL150 V4.7, SINAMICS SM120 V4.7, SINUMERIK 828D, SINUMERIK 840D sl. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autenticado desencadenar una condici\u00f3n de denegaci\u00f3n de servicio. La vulnerabilidad puede activarse si se env\u00eda al dispositivo una gran cantidad de paquetes UDP especialmente dise\u00f1ados. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda ninguna explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad" } ], "id": "CVE-2019-10936", "lastModified": "2024-11-21T04:20:11.257", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Secondary" } ] }, "published": "2019-10-10T14:15:14.707", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-07-13 11:15
Modified
2024-12-10 14:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-599968.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-599968.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | dk_standard_ethernet_controller_evaluation_kit_firmware | * | |
siemens | dk_standard_ethernet_controller_evaluation_kit | - | |
siemens | ek-ertec_200_evaulation_kit_firmware | * | |
siemens | ek-ertec_200_evaulation_kit | - | |
siemens | ek-ertec_200p_evaluation_kit_firmware | * | |
siemens | ek-ertec_200p_evaluation_kit | - | |
siemens | ruggedcom_rm1224_firmware | * | |
siemens | ruggedcom_rm1224 | - | |
siemens | scalance_m-800_firmware | * | |
siemens | scalance_m-800 | - | |
siemens | scalance_s615_firmware | * | |
siemens | scalance_s615 | - | |
siemens | scalance_w700_firmware | * | |
siemens | scalance_w700 | - | |
siemens | scalance_w1700_firmware | * | |
siemens | scalance_w1700 | - | |
siemens | scalance_x200-4_p_irt_firmware | * | |
siemens | scalance_x200-4_p_irt | - | |
siemens | scalance_x201-3p_irt_firmware | * | |
siemens | scalance_x201-3p_irt | - | |
siemens | scalance_x201-3p_irt_pro_firmware | * | |
siemens | scalance_x201-3p_irt_pro | - | |
siemens | scalance_x202-2_irt_firmware | * | |
siemens | scalance_x202-2_irt | - | |
siemens | scalance_x202-2p_irt_pro_firmware | * | |
siemens | scalance_x202-2p_irt_pro | - | |
siemens | scalance_x204_irt_firmware | * | |
siemens | scalance_x204_irt | - | |
siemens | scalance_x204_irt_pro_firmware | * | |
siemens | scalance_x204_irt_pro | - | |
siemens | scalance_x204-2_firmware | * | |
siemens | scalance_x204-2_ | - | |
siemens | scalance_x204-2fm_firmware | * | |
siemens | scalance_x204-2fm | - | |
siemens | scalance_x204-2ld_firmware | * | |
siemens | scalance_x204-2ld | - | |
siemens | scalance_x204-2ld_ts_firmware | * | |
siemens | scalance_x204-2ld_ts | - | |
siemens | scalance_x204-2ts_firmware | * | |
siemens | scalance_x204-2ts | - | |
siemens | scalance_x206-1_firmware | * | |
siemens | scalance_x206-1 | - | |
siemens | scalance_x206-1ld_firmware | * | |
siemens | scalance_x206-1ld | - | |
siemens | scalance_x208_firmware | * | |
siemens | scalance_x208 | - | |
siemens | scalance_x208pro_firmware | * | |
siemens | scalance_x208pro | - | |
siemens | scalance_x212-2_firmware | * | |
siemens | scalance_x212-2 | - | |
siemens | scalance_x212-2ld_firmware | * | |
siemens | scalance_x212-2ld | - | |
siemens | scalance_x216_firmware | * | |
siemens | scalance_x216 | - | |
siemens | scalance_x224_firmware | * | |
siemens | scalance_x224 | - | |
siemens | scalance_x302-7eec_firmware | * | |
siemens | scalance_x302-7eec | - | |
siemens | scalance_x304-2fe_firmware | * | |
siemens | scalance_x304-2fe | - | |
siemens | scalance_x306-1ldfe_firmware | * | |
siemens | scalance_x306-1ldfe | - | |
siemens | scalance_x307-2eec_firmware | * | |
siemens | scalance_x307-2eec | - | |
siemens | scalance_x307-3_firmware | * | |
siemens | scalance_x307-3 | - | |
siemens | scalance_x307-3ld_firmware | * | |
siemens | scalance_x307-3ld | - | |
siemens | scalance_x308-2_firmware | * | |
siemens | scalance_x308-2 | - | |
siemens | scalance_x308-2ld_firmware | * | |
siemens | scalance_x308-2ld | - | |
siemens | scalance_x308-2lh_firmware | * | |
siemens | scalance_x308-2lh | - | |
siemens | scalance_x308-2lh\+_firmware | * | |
siemens | scalance_x308-2lh\+ | - | |
siemens | scalance_x308-2m_firmware | * | |
siemens | scalance_x308-2m | - | |
siemens | scalance_x308-2m_poe_firmware | * | |
siemens | scalance_x308-2m_poe | - | |
siemens | scalance_x308-2m_ts_firmware | * | |
siemens | scalance_x308-2m_ts | - | |
siemens | scalance_x310_firmware | * | |
siemens | scalance_x310 | - | |
siemens | scalance_x310fe_firmware | * | |
siemens | scalance_x310fe | - | |
siemens | scalance_x320-1fe_firmware | * | |
siemens | scalance_x320-1fe | - | |
siemens | scalance_x320-3ldfe_firmware | * | |
siemens | scalance_x320-3ldfe | - | |
siemens | scalance_xb-200_firmware | * | |
siemens | scalance_xb-200 | - | |
siemens | scalance_xc-200_firmware | * | |
siemens | scalance_xc-200 | - | |
siemens | scalance_xf201-3p_irt_firmware | * | |
siemens | scalance_xf201-3p_irt | - | |
siemens | scalance_xf202-2p_irt_firmware | * | |
siemens | scalance_xf202-2p_irt | - | |
siemens | scalance_xf204_firmware | * | |
siemens | scalance_xf204 | - | |
siemens | scalance_xf204_irt_firmware | * | |
siemens | scalance_xf204_irt | - | |
siemens | scalance_xf204-2_firmware | * | |
siemens | scalance_xf204-2_ | - | |
siemens | scalance_xf204-2ba_irt_firmware | * | |
siemens | scalance_xf204-2ba_irt | - | |
siemens | scalance_xf206-1_firmware | * | |
siemens | scalance_xf206-1 | - | |
siemens | scalance_xf208_firmware | * | |
siemens | scalance_xf208 | - | |
siemens | scalance_xf-200ba_firmware | * | |
siemens | scalance_xf-200ba | - | |
siemens | scalance_xm400_firmware | * | |
siemens | scalance_xm400 | - | |
siemens | scalance_xp-200_firmware | * | |
siemens | scalance_xp-200 | - | |
siemens | scalance_xr324-4m_eec_firmware | * | |
siemens | scalance_xr324-4m_eec | - | |
siemens | scalance_xr324-4m_poe_firmware | * | |
siemens | scalance_xr324-4m_poe | - | |
siemens | scalance_xr324-4m_poe_ts_firmware | * | |
siemens | scalance_xr324-4m_poe_ts | - | |
siemens | scalance_xr324-12m_firmware | * | |
siemens | scalance_xr324-12m | - | |
siemens | scalance_xr324-12m_ts_firmware | * | |
siemens | scalance_xr324-12m_ts | - | |
siemens | scalance_xr500_firmware | * | |
siemens | scalance_xr500 | - | |
siemens | scalance_xr-300wg_firmware | * | |
siemens | scalance_xr-300wg | - | |
siemens | simatic_cfu_pa_firmware | * | |
siemens | simatic_cfu_pa | - | |
siemens | simatic_ie\/pb-link_v3_firmware | * | |
siemens | simatic_ie\/pb-link_v3 | - | |
siemens | simatic_mv500_firmware | * | |
siemens | simatic_mv500 | - | |
siemens | simatic_net_cm_1542-1_firmware | * | |
siemens | simatic_net_cm_1542-1 | - | |
siemens | simatic_net_cp1616_firmware | * | |
siemens | simatic_net_cp1616 | - | |
siemens | simatic_net_cp1604_firmware | * | |
siemens | simatic_net_cp1604 | - | |
siemens | simatic_net_cp1626_firmware | * | |
siemens | simatic_net_cp1626 | - | |
siemens | simatic_net_dk-16xx_pn_io | * | |
siemens | simatic_power_line_booster_plb_firmware | * | |
siemens | simatic_power_line_booster_plb | - | |
siemens | simatic_profinet_driver_firmware | * | |
siemens | simatic_profinet_driver | - | |
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simocode_prov_ethernet\/ip_firmware | * | |
siemens | simocode_prov_ethernet\/ip | - | |
siemens | simocode_prov_profinet_firmware | * | |
siemens | simocode_prov_profinet | - | |
siemens | softnet-ie_pnio_firmware | * | |
siemens | softnet-ie_pnio | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_evaluation_kit_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1BA1C1FD-EF49-488E-AB49-6F571D9E21B0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller_evaluation_kit:-:*:*:*:*:*:*:*", "matchCriteriaId": "83110E06-CDB2-49AE-B1E6-6785E0801A53", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_evaulation_kit_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "978998A4-C7B5-4D6D-9FAD-3C6F975C8881", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200_evaulation_kit:-:*:*:*:*:*:*:*", "matchCriteriaId": "12C60870-6B8C-4E91-B156-60D87B85543F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_evaluation_kit_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "249935E8-C45B-4586-B6BA-664AF23C7468", "versionEndExcluding": "4.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_evaluation_kit:-:*:*:*:*:*:*:*", "matchCriteriaId": "37176F8D-F1CB-4792-86FF-DA0FF674E0B8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "758CC5D1-F26C-4093-BE09-0583F4CDBBDB", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*", "matchCriteriaId": "284DF779-D900-48B4-A177-7281CD445AB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02BC878B-BF73-4A2C-A9D5-F9FF0F3D418B", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F5AD34D-61AA-47B0-993A-4834984893EA", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60CB864-640E-4BC2-B378-5AF3DCA292D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44B0E5EA-4924-4865-AE6F-2F7BFCE5513B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200-4_p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8FCE9120-8091-41EC-A75E-01ED4AF64E28", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200-4_p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "73E42E20-18CB-40A7-B6D5-751F26303995", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA86FF0D-7B16-4991-B4A5-AF33BF40693A", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "3268CF75-6DAB-416A-B19B-2A8F95C268CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA2326FF-5125-44F5-871C-2DC505E2B299", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "492E8AC1-338B-4AC3-90C7-1FADCD4528C4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x202-2_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A12E0F8-A7BB-48E9-98E5-7DA4962FA8AE", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x202-2_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "577D1E21-717C-4508-AE91-0BC490C89F85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29C03AD0-7A60-4BFB-A0D3-BABB9717F1A1", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4726901-34BF-4F70-80A6-71648A4A29FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "576A1BD5-84DE-4FFC-926D-6C40E5176660", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BC31F0E-389B-4925-88DE-726F2F0D2A23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204_irt_pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFE2ABF4-2996-4671-A5AF-4424FB2537C1", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204_irt_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FF096BA-A6F4-46B3-9B9B-7FCEE7E6A6C3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACE1A821-8F0A-4B96-AC8A-B219215014B1", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2_:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AA16CFF-C01A-4AC0-A20E-50CBD3AA1C3E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54201E08-15E3-4C93-9A0D-DC376B7C8D88", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*", "matchCriteriaId": "1FCBC784-8EA0-4C6C-B504-DFC164028E4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "75220631-DD7D-4E86-8405-F98340FFE27C", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BE27611-53E7-4162-8630-5BC334B02E37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3032A499-DFD5-4FEA-8AC6-E661781387AB", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "1FDEBD6B-6BE4-4FAD-A4E6-BE762595434D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A493C49A-8BF9-43E5-98D5-55E5390A36A5", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5FFC1E9-4326-4F41-A86A-C52AB6A9A674", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2C9747F-BEC3-486E-B553-3339F8B54C3A", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A5BB0F2-DD4C-4AB4-9B8F-B2501B239080", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C8D68AC-8F30-4919-ADB3-A6018458602B", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DFF7FB7-774B-45ED-8400-951230DF0511", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BC1450A-92ED-451F-9890-4E18CA974485", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*", "matchCriteriaId": "B3B574E2-F7BA-496B-887C-D25F386AA5E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "768320F0-10F5-4B36-AEB6-9DEEA43A30E8", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF2C60CF-4089-4993-A2CB-B7FBDAF81D62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31B8367C-5EAC-49F4-83B8-C7E3BD373092", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E716A4E-50A9-4C52-8DA9-098F7506F4B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55F50ABF-3E9A-4435-BAA4-7D11A2047D46", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "C08CDEE3-43EB-475E-8571-6E12824714FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC643617-D0B7-4379-8ADB-2C2BACA4B165", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0C4BAB5-E161-4B59-8A8C-369C7852A66E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0189DF6-DA80-49FE-B09F-0C07D892518E", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2203895-BC4E-4B2F-9110-C2CD88A121F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF92A1A7-ADFB-49E1-AC54-03E32ECB73CE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8E97B3B-1808-45D2-97B7-CF31CA6E7A60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "392D0623-343D-4BF1-BE0B-F2B347A24B62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "0087A1C6-AA76-4FD6-BAA1-D3190D2A0116", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663897D9-82F5-436D-A0CF-BBB9338BF363", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*", "matchCriteriaId": "880CF41B-B25D-4744-8E8B-C4B131932B1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9666E7EA-A298-4972-80F8-765B0F99EB25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "804EE08B-75A1-4CF6-9C30-8CF0CDC39658", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9676DB10-982D-445F-9779-B39AE720AF2F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48D3EB09-6069-4289-A61E-C15B044EA2E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "7737F0C2-43FC-4330-88F2-9B08BA5B35D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "40A1A5F9-4971-4E9D-BBE7-5A0357C56213", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE1909FA-C8C6-46BE-83C6-2635D36FE69B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F53C74B-2154-417E-ACFE-01F0BACD3F15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DDBD94D-5312-4A54-AF76-D9DF791C0292", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D76A2268-5397-466C-98B5-01B46B4840A1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*", "matchCriteriaId": "85153EED-C677-495D-A6BB-72365DE1ED3F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F8888A7-3285-4ACA-A5AD-2B0578050C4C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*", "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C08597D-6190-4C73-9ECF-2535553DECAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2C12934-E79C-41A4-B023-BADD7D68CB55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFCCB68C-A58D-4543-A11F-721B01FFBBA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D288227C-69C1-4248-AB4A-51F44A41FDEA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*", "matchCriteriaId": "7FE3716E-1C0A-4B72-809A-8318E5853FB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FB34E83-83A3-45C3-B040-D8910971D439", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91EDD23A-1DBD-4117-9396-89ADBC705B3A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC54880F-CBF4-4772-A4FB-B07D97287D44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF07B014-1BA3-477E-A405-5DB35F68126A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*", "matchCriteriaId": "80502856-7617-4ED9-A103-681021131EE0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B5557DB0-D3D8-4E53-BBA8-700B2BC336C0", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "41614C70-97B4-44C8-A441-530A413A26F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1A7EDE9-B5F9-4471-8C5D-B1D590CB85FB", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "6751FB7D-C72C-4321-B535-5880FE696FC3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8CD13707-1164-415E-9083-7946D151F1FC", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F1AE867-67B4-4871-BF56-88017533A737", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86FBD0DA-ADA4-4F06-A2D6-11D7312257A2", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "25DDF1EB-80E7-491F-A197-1B220E35CDF1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A09FF2D-F369-47B5-AEE4-A862BEDD9851", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204-2_:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C4207E0-7678-4E35-A79E-A6066D1E8BB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "786738CF-CA6C-4812-BD4D-595E249BFA76", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFCDC84E-0695-409A-844B-D24024CC33F2", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "2B40D2EB-5C69-47FA-801B-DC48407D418C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1DB6C03-71BF-4359-834B-384E78910E64", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*", "matchCriteriaId": "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D589735-017F-4675-8056-CA4FE57360E8", "versionEndExcluding": "6.3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*", "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*", "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32E2B545-326C-4724-90BC-147B57A37F20", "versionEndExcluding": "6.3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5119182-CB31-466A-AB0F-7956C8B45AE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ie\\/pb-link_v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A8C0F9C-AF27-424C-83F0-326EC10C40BE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ie\\/pb-link_v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "939D9324-2A7F-4DBF-8F9F-DB8A379C977A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDEAC63C-E402-4698-B4A8-E9B53D5540DA", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*", "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cm_1542-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "761C2EC9-51B9-482B-8798-7982D265933D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cm_1542-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "40757A32-7347-4975-BC01-A1B28760D2C3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1616_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4575EFA7-C453-466D-9C37-38FEE0B78053", "versionEndIncluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B971242-13BA-4217-8FB0-92ACDCE463CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1604_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9F73267-3A7A-4A38-B999-9877B173B518", "versionEndIncluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "A0DB421E-A774-451F-85AB-E66A4FAA33A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1626_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18143A38-84B8-479E-99FB-93FCA8CB058D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1626:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B0286CB-0566-4306-B069-789E5A4F168F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_net_dk-16xx_pn_io:*:*:*:*:*:*:*:*", "matchCriteriaId": "78430123-6230-4B76-B163-CDA3FA77413C", "versionEndIncluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_power_line_booster_plb_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AAAECA7-6936-48AD-B617-79F4C708E47F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_power_line_booster_plb:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7B52AEC-7A90-49F2-8006-FC146405C3E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE64639F-FC6D-43F6-A300-9B5A62495B27", "versionEndExcluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", "matchCriteriaId": "526493E9-EF74-4836-9A8F-134B625035AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6870C5CC-B7E0-45C3-9D98-F90765EE153F", "versionEndExcluding": "4.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_prov_ethernet\\/ip_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FBDC4FD6-06A6-4728-B8A0-D896CD89FD3E", "versionEndExcluding": "1.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_prov_ethernet\\/ip:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CBAF8CF-6159-46D2-AB92-7CB5BFA7467B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_prov_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27AC468E-63F9-443B-906C-D1794B846744", "versionEndExcluding": "2.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_prov_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "E595680D-555C-4A8E-A409-88CBCE6681E6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:softnet-ie_pnio_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45650D6F-1F5F-4DC8-BF5C-C4FBE3D3E39D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:softnet-ie_pnio:-:*:*:*:*:*:*:*", "matchCriteriaId": "B8673C81-91F5-4E74-8C5F-829040F39E0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." }, { "lang": "es", "value": "Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condici\u00f3n de denegaci\u00f3n de servicio. La vulnerabilidad puede activarse si se env\u00eda una gran cantidad de paquetes de restablecimiento de DCP al dispositivo" } ], "id": "CVE-2020-28400", "lastModified": "2024-12-10T14:15:19.373", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2021-07-13T11:15:08.960", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }