All the vulnerabilites related to siemens - simatic_rtu3041c_firmware
Vulnerability from fkie_nvd
Published
2021-09-14 11:15
Modified
2024-11-21 06:14
Summary
A vulnerability has been identified in LOGO! CMR2020 (All versions < V2.2), LOGO! CMR2040 (All versions < V2.2), SIMATIC RTU3010C (All versions < V4.0.9), SIMATIC RTU3030C (All versions < V4.0.9), SIMATIC RTU3031C (All versions < V4.0.9), SIMATIC RTU3041C (All versions < V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2020_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE9FB0B2-71ED-4208-B908-1C78CB15E372",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2020:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8E5F42B-63E3-4B2D-A03F-983F51EE0648",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2040_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECD83A4C-DB7F-425C-882C-0DC809AD4A21",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2040:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ED47A12-5637-40E2-BE39-B76B789C0DFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3010c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "74470D59-9DA5-434A-893F-A3E2EC5E18F8",
              "versionEndExcluding": "4.0.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3010c:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3279084C-DCED-41B0-BCA1-684877FB66CC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3030c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0761C6A3-BDE5-4009-9EEA-B86770636267",
              "versionEndExcluding": "4.0.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3030c:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C36A82A5-9E25-4166-9A26-2172DEEE3F34",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3031c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2DF2794C-D474-41AA-BF54-53B52F446F13",
              "versionEndExcluding": "4.0.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3031c:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "11CF1847-8D15-44C3-8D90-2172C09DE8C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3041c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "74F400D8-9118-41FC-AAF5-D945EE62FF67",
              "versionEndExcluding": "4.0.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3041c:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E493A416-E988-4697-81B3-B0AA27531F13",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in LOGO! CMR2020 (All versions \u003c V2.2), LOGO! CMR2040 (All versions \u003c V2.2), SIMATIC RTU3010C (All versions \u003c V4.0.9), SIMATIC RTU3030C (All versions \u003c V4.0.9), SIMATIC RTU3031C (All versions \u003c V4.0.9), SIMATIC RTU3041C (All versions \u003c V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en LOGO! CMR2020 (Todas las versiones anteriores a la versi\u00f3n V2.2), LOGO! CMR2040 (Todas las versiones anteriores a la versi\u00f3n V2.2), SIMATIC RTU3010C (Todas las versiones anteriores a la versi\u00f3n V4.0.9), SIMATIC RTU3030C (Todas las versiones anteriores a la versi\u00f3n V4.0.9), SIMATIC RTU3031C (Todas las versiones anteriores a la versi\u00f3n V4.0.9), SIMATIC RTU3041C (Todas las versiones anteriores a la versi\u00f3n V4.0.9). La pila TCP/IP subyacente no calcula apropiadamente los n\u00fameros aleatorios usados como ISN (Initial Sequence Numbers). Un atacante adyacente con acceso a la red de la interfaz LAN podr\u00eda interferir en el tr\u00e1fico, falsear la conexi\u00f3n y conseguir acceso a informaci\u00f3n confidencial"
    }
  ],
  "id": "CVE-2021-37186",
  "lastModified": "2024-11-21T06:14:49.183",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 4.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.4,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.5,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-09-14T11:15:25.850",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-330"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-08-23 02:15
Modified
2024-11-21 05:29
Summary
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). A NULL algorithm parameters entry looks identical to an array of REAL (size zero) and thus the certificate is considered valid. However, if the parameters do not match in any way, then the certificate should be considered invalid.
References
cve@mitre.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdfPatch, Third Party Advisory
cve@mitre.orghttps://github.com/ARMmbed/mbedtls/issues/3629Exploit, Third Party Advisory
cve@mitre.orghttps://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9Release Notes, Third Party Advisory
cve@mitre.orghttps://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0Release Notes, Third Party Advisory
cve@mitre.orghttps://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18Release Notes, Third Party Advisory
cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2021/11/msg00021.htmlMailing List, Third Party Advisory
cve@mitre.orghttps://lists.debian.org/debian-lts-announce/2022/12/msg00036.htmlMailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdfPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://github.com/ARMmbed/mbedtls/issues/3629Exploit, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9Release Notes, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0Release Notes, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18Release Notes, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/11/msg00021.htmlMailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2022/12/msg00036.htmlMailing List, Third Party Advisory



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1399656-491A-428C-B290-5303A59B7C0E",
              "versionEndExcluding": "2.7.18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DD8F7D9-7E6F-4C31-A38C-D4B246F713FF",
              "versionEndExcluding": "2.16.9",
              "versionStartIncluding": "2.8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57294BAA-C692-4C66-96E9-7B653E32D88C",
              "versionEndExcluding": "2.25.0",
              "versionStartIncluding": "2.17.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2020_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE9FB0B2-71ED-4208-B908-1C78CB15E372",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2020:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8E5F42B-63E3-4B2D-A03F-983F51EE0648",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2040_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECD83A4C-DB7F-425C-882C-0DC809AD4A21",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2040:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ED47A12-5637-40E2-BE39-B76B789C0DFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3031c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64954FA1-0F30-4D1D-8218-C3BA84C5AAF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3031c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48F0595C-286F-4EB1-8C25-D20FB92A95A0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3041c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0307A2DD-B616-4551-8C31-0B0EBE4A4B12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3041c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E57561E2-DC49-4D11-BBF1-40E7B14A6873",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3030c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61C3C191-5CEE-46F7-9231-BD2E246130E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3030c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A66DD04-4C58-45D8-A8C5-6817B05DBA14",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3000c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B3325EA-59B3-4BB6-923D-0D89CB8AAC25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3000c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E902CE-D319-4FC9-BC9B-7D8DB83FAD9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). A NULL algorithm parameters entry looks identical to an array of REAL (size zero) and thus the certificate is considered valid. However, if the parameters do not match in any way, then the certificate should be considered invalid."
    },
    {
      "lang": "es",
      "value": "Se ha detectado un problema en Mbed TLS versiones anteriores a 2.25.0 (y versiones anteriores a 2.16.9 LTS y versiones anteriores a 2.7.18 LTS). Una entrada de par\u00e1metros de algoritmo NULL parece id\u00e9ntica a una matriz de REAL (tama\u00f1o cero) y, por tanto, el certificado es considerado v\u00e1lido. Sin embargo, si los par\u00e1metros no coinciden de ninguna manera, el certificado debe considerarse no v\u00e1lido."
    }
  ],
  "id": "CVE-2020-36478",
  "lastModified": "2024-11-21T05:29:38.247",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-23T02:15:07.097",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/issues/3629"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/issues/3629"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-295"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-08-23 02:15
Modified
2024-11-21 05:29
Summary
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1399656-491A-428C-B290-5303A59B7C0E",
              "versionEndExcluding": "2.7.18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DD8F7D9-7E6F-4C31-A38C-D4B246F713FF",
              "versionEndExcluding": "2.16.9",
              "versionStartIncluding": "2.8.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:arm:mbed_tls:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "57294BAA-C692-4C66-96E9-7B653E32D88C",
              "versionEndExcluding": "2.25.0",
              "versionStartIncluding": "2.17.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2020_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE9FB0B2-71ED-4208-B908-1C78CB15E372",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2020:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8E5F42B-63E3-4B2D-A03F-983F51EE0648",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:logo\\!_cmr2040_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ECD83A4C-DB7F-425C-882C-0DC809AD4A21",
              "versionEndExcluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:logo\\!_cmr2040:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ED47A12-5637-40E2-BE39-B76B789C0DFD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3031c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64954FA1-0F30-4D1D-8218-C3BA84C5AAF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3031c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48F0595C-286F-4EB1-8C25-D20FB92A95A0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3041c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0307A2DD-B616-4551-8C31-0B0EBE4A4B12",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3041c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E57561E2-DC49-4D11-BBF1-40E7B14A6873",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3030c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61C3C191-5CEE-46F7-9231-BD2E246130E1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3030c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A66DD04-4C58-45D8-A8C5-6817B05DBA14",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rtu3000c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B3325EA-59B3-4BB6-923D-0D89CB8AAC25",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rtu3000c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E902CE-D319-4FC9-BC9B-7D8DB83FAD9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs."
    },
    {
      "lang": "es",
      "value": "Se ha detectado un problema en Mbed TLS versiones anteriores a 2.25.0 (y versiones anteriores a 2.16.9 LTS y versiones anteriores a 2.7.18 LTS). Los c\u00e1lculos llevado a cabo por la funci\u00f3n  mbedtls_mpi_exp_mod no est\u00e1n limitados; por lo tanto, el suministro de par\u00e1metros demasiado grandes podr\u00eda conllevar a una denegaci\u00f3n de servicio cuando se generan pares de claves Diffie-Hellman."
    }
  ],
  "id": "CVE-2020-36475",
  "lastModified": "2024-11-21T05:29:37.603",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-23T02:15:06.930",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Release Notes",
        "Third Party Advisory"
      ],
      "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-131"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2020-36478
Vulnerability from cvelistv5
Published
2021-08-23 00:00
Modified
2024-08-04 17:30
Severity ?
Summary
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). A NULL algorithm parameters entry looks identical to an array of REAL (size zero) and thus the certificate is considered valid. However, if the parameters do not match in any way, then the certificate should be considered invalid.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:30:07.313Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/issues/3629"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
          },
          {
            "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
          },
          {
            "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). A NULL algorithm parameters entry looks identical to an array of REAL (size zero) and thus the certificate is considered valid. However, if the parameters do not match in any way, then the certificate should be considered invalid."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
        },
        {
          "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
        },
        {
          "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
        },
        {
          "url": "https://github.com/ARMmbed/mbedtls/issues/3629"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
        },
        {
          "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
        },
        {
          "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-36478",
    "datePublished": "2021-08-23T00:00:00",
    "dateReserved": "2021-08-23T00:00:00",
    "dateUpdated": "2024-08-04T17:30:07.313Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2020-36475
Vulnerability from cvelistv5
Published
2021-08-23 00:00
Modified
2024-08-04 17:30
Severity ?
Summary
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:30:08.223Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
          },
          {
            "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
          },
          {
            "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-26T00:00:00",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.25.0"
        },
        {
          "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.16.9"
        },
        {
          "url": "https://github.com/ARMmbed/mbedtls/releases/tag/v2.7.18"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-756638.pdf"
        },
        {
          "name": "[debian-lts-announce] 20211123 [SECURITY] [DLA 2826-1] mbedtls security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/11/msg00021.html"
        },
        {
          "name": "[debian-lts-announce] 20221225 [SECURITY] [DLA 3249-1] mbedtls security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/12/msg00036.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-36475",
    "datePublished": "2021-08-23T00:00:00",
    "dateReserved": "2021-08-23T00:00:00",
    "dateUpdated": "2024-08-04T17:30:08.223Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-37186
Vulnerability from cvelistv5
Published
2021-09-14 10:47
Modified
2024-08-04 01:16
Severity ?
Summary
A vulnerability has been identified in LOGO! CMR2020 (All versions < V2.2), LOGO! CMR2040 (All versions < V2.2), SIMATIC RTU3010C (All versions < V4.0.9), SIMATIC RTU3030C (All versions < V4.0.9), SIMATIC RTU3031C (All versions < V4.0.9), SIMATIC RTU3041C (All versions < V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information.
Impacted products
Vendor Product Version
Siemens LOGO! CMR2040 Version: All versions < V2.2
Siemens SIMATIC RTU3010C Version: All versions < V4.0.9
Siemens SIMATIC RTU3030C Version: All versions < V4.0.9
Siemens SIMATIC RTU3031C Version: All versions < V4.0.9
Siemens SIMATIC RTU3041C Version: All versions < V4.0.9
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.873Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LOGO! CMR2020",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2"
            }
          ]
        },
        {
          "product": "LOGO! CMR2040",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2"
            }
          ]
        },
        {
          "product": "SIMATIC RTU3010C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0.9"
            }
          ]
        },
        {
          "product": "SIMATIC RTU3030C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0.9"
            }
          ]
        },
        {
          "product": "SIMATIC RTU3031C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0.9"
            }
          ]
        },
        {
          "product": "SIMATIC RTU3041C",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0.9"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in LOGO! CMR2020 (All versions \u003c V2.2), LOGO! CMR2040 (All versions \u003c V2.2), SIMATIC RTU3010C (All versions \u003c V4.0.9), SIMATIC RTU3030C (All versions \u003c V4.0.9), SIMATIC RTU3031C (All versions \u003c V4.0.9), SIMATIC RTU3041C (All versions \u003c V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-330",
              "description": "CWE-330: Use of Insufficiently Random Values",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-02-09T15:16:46",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-37186",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LOGO! CMR2020",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "LOGO! CMR2040",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RTU3010C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RTU3030C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RTU3031C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.0.9"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC RTU3041C",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.0.9"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in LOGO! CMR2020 (All versions \u003c V2.2), LOGO! CMR2040 (All versions \u003c V2.2), SIMATIC RTU3010C (All versions \u003c V4.0.9), SIMATIC RTU3030C (All versions \u003c V4.0.9), SIMATIC RTU3031C (All versions \u003c V4.0.9), SIMATIC RTU3041C (All versions \u003c V4.0.9). The underlying TCP/IP stack does not properly calculate the random numbers used as ISN (Initial Sequence Numbers). An adjacent attacker with network access to the LAN interface could interfere with traffic, spoof the connection and gain access to sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-330: Use of Insufficiently Random Values"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-316383.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37186",
    "datePublished": "2021-09-14T10:47:49",
    "dateReserved": "2021-07-21T00:00:00",
    "dateUpdated": "2024-08-04T01:16:03.873Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}