cve-2019-13945
Vulnerability from cvelistv5
Published
2019-12-12 13:19
Modified
2024-08-05 00:05
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf | x_refsource_MISC |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:05:44.067Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-1200 CPU family \u003c V4.x (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions with Function State (FS) \u003c 11" } ] }, { "product": "SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] }, { "product": "SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] }, { "product": "SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.2.2 and Function State (FS) \u003c= 8" } ] }, { "product": "SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] }, { "product": "SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.2.2 and Function State (FS) \u003c= 10" } ] }, { "product": "SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] }, { "product": "SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 11" } ] }, { "product": "SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10" } ] }, { "product": "SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10" } ] }, { "product": "SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 12" } ] }, { "product": "SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9" } ] }, { "product": "SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9" } ] }, { "product": "SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8" } ] }, { "product": "SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8" } ] }, { "product": "SIMATIC S7-200 SMART CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family \u003c V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) \u003c 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-749", "description": "CWE-749: Exposed Dangerous Method or Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-14T13:18:04", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-13945", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-1200 CPU family \u003c V4.x (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions with Function State (FS) \u003c 11" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.2.2 and Function State (FS) \u003c= 8" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.2.2 and Function State (FS) \u003c= 10" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 11" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 12" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0)", "version": { "version_data": [ { "version_value": "All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8" } ] } }, { "product_name": "SIMATIC S7-200 SMART CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family \u003c V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) \u003c 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-749: Exposed Dangerous Method or Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-13945", "datePublished": "2019-12-12T13:19:51", "dateReserved": "2019-07-18T00:00:00", "dateUpdated": "2024-08-05T00:05:44.067Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-12741
Vulnerability from cvelistv5
Published
2017-12-26 04:00
Modified
2024-08-05 18:51
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
References
▼ | URL | Tags |
---|---|---|
https://www.securityfocus.com/bid/101964 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/html/ssa-346262.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-141614.html |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch 05 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T18:51:06.315Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch 05" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Compact Field Unit", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.03.01" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.16", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P V4.4 and V4.5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF5" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION P V5", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.1 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP9 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP9 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF6" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF29" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.02" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:53.948Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "101964", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "https://www.securityfocus.com/bid/101964" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-12741", "datePublished": "2017-12-26T04:00:00", "dateReserved": "2017-08-09T00:00:00", "dateUpdated": "2024-08-05T18:51:06.315Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-2680
Vulnerability from cvelistv5
Published
2017-05-11 01:00
Modified
2024-09-10 09:33
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | x_refsource_CONFIRM | |
https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_CONFIRM | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
https://cert-portal.siemens.com/productcert/html/ssa-546832.html |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch04 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2680", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T13:26:04.237652Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-09T13:26:15.327Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.270Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 12\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 15\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 19\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "Extension Unit 22\" PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V01.01.01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1242-7 V2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-7 LTE US", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION D4xx V4.4 for SINAMICS SM150i-2 w. PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 HF26" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GH150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP5 HF7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GL150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS GM150 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF31" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.0 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF30" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.4 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SL150 V4.7.5 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS SM120 V4.7 w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 SP2" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:18.492Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2680", "datePublished": "2017-05-11T01:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:18.492Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2013-0700
Vulnerability from cvelistv5
Published
2013-04-22 01:00
Modified
2024-08-06 14:33
Severity ?
EPSS score ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T14:33:05.470Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2012-12-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-10T14:06:52", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2013-0700", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2013-0700", "datePublished": "2013-04-22T01:00:00", "dateReserved": "2012-12-19T00:00:00", "dateUpdated": "2024-08-06T14:33:05.470Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2018-13815
Vulnerability from cvelistv5
Published
2018-12-13 16:00
Modified
2024-08-05 09:14
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/105928 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens AG | SIMATIC S7-1200, SIMATIC S7-1500 |
Version: SIMATIC S7-1200 : All versions Version: SIMATIC S7-1500 : All Versions < V2.6 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T09:14:47.135Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "105928", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/105928" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-1200, SIMATIC S7-1500", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "SIMATIC S7-1200 : All versions" }, { "status": "affected", "version": "SIMATIC S7-1500 : All Versions \u003c V2.6" } ] } ], "datePublic": "2018-12-13T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions \u003c V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-410", "description": "CWE-410: Insufficient Resource Pool", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2018-12-14T10:57:02", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "105928", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/105928" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2018-13815", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-1200, SIMATIC S7-1500", "version": { "version_data": [ { "version_value": "SIMATIC S7-1200 : All versions" }, { "version_value": "SIMATIC S7-1500 : All Versions \u003c V2.6" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions \u003c V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-410: Insufficient Resource Pool" } ] } ] }, "references": { "reference_data": [ { "name": "105928", "refsource": "BID", "url": "http://www.securityfocus.com/bid/105928" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2018-13815", "datePublished": "2018-12-13T16:00:00", "dateReserved": "2018-07-10T00:00:00", "dateUpdated": "2024-08-05T09:14:47.135Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2017-2681
Vulnerability from cvelistv5
Published
2017-05-11 10:00
Modified
2024-09-10 09:33
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
7.1 (High) - CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags |
---|---|---|
http://www.securitytracker.com/id/1038463 | vdb-entry, x_refsource_SECTRACK | |
http://www.securityfocus.com/bid/98369 | vdb-entry, x_refsource_BID | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/html/ssa-293562.html |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions < V4.1.1 Patch04 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2017-2681", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-23T20:22:19.045364Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-23T20:22:26.181Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-05T14:02:07.386Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.1 Patch04" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1 Patch03" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0 Patch01" } ] }, { "defaultStatus": "unknown", "product": "IE/AS-i Link PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "IE/PB-Link (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.03" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W-700 IEEE 802.11n family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.2.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V5.4.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.1.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X414", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.10.2" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM-400 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR-500 family", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V6.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542SP-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1243-8 IRC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.82" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0.15" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.17" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 443-1 OPC UA", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "lessThan": "V1.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200M (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-3 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-4 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN BA", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.0.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN: IO-Link Master", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200S (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-B Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV420 SR-P Body", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 HR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 SR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV440 UR", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF650R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF680R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF685R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-200 SMART", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V3.X.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.6", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V7.0.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.8", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Advanced", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Basic", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Teleservice Adapter IE Standard", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2010 SP3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMOTION", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.4 SP1 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCP w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP6 HF3" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V4.7: All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4 SP3 HF5" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.7 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 HF27" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150 V4.8 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.8 HF4" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90 w. PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.01" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 828D V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.5 and prior", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.5 SP6 HF2" } ] }, { "defaultStatus": "unknown", "product": "SINUMERIK 840D sl V4.7", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7 SP4 HF1" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS ACT 3SU1 interface module PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.0" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Motor Starter M200D PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIRIUS Soft Starter 3RW44 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SITOP PSU8600 PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.2.0" } ] }, { "defaultStatus": "unknown", "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.2.0" } ] }, { "defaultStatus": "unknown", "product": "Softnet PROFINET IO for PC-based Windows systems", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V14 SP1" } ] } ], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:33:20.658Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "1038463", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1038463" }, { "name": "98369", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/98369" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2017-2681", "datePublished": "2017-05-11T10:00:00", "dateReserved": "2016-12-01T00:00:00", "dateUpdated": "2024-09-10T09:33:20.658Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-28400
Vulnerability from cvelistv5
Published
2021-07-13 11:02
Modified
2024-12-10 13:53
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
8.7 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller |
Version: All versions |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "status": "affected", "version": "0" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_dk_standard_ethernet_controller", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:development_evaluation_kits_for_profinet_io_ek_ertec_200p:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "development_evaluation_kits_for_profinet_io_ek_ertec_200p", "vendor": "siemens", "versions": [ { "lessThan": "v4.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:ruggedcom_rm1224:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "ruggedcom_rm1224", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_m804pb:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m804pb", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_a", "vendor": "seimens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:seimens:scalance_m812-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m812-1_adsl-router_annex_b", "vendor": "seimens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816_1_adsl_router_annex_a:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816_1_adsl_router_annex_a", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m816-1_adsl-router_annex_b:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m816-1_adsl-router_annex_b", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m826-2_shdsl-router:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m826-2_shdsl-router", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_2", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_m874_3:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_m874_3", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_evdo:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_evdo", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_3_rok:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_3_rok", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_eu:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_eu", "vendor": "siemens", "versions": [ { "lessThan": "6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_m876_4_nam:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_m876_4_nam", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_s615", "vendor": "siemens", "versions": [ { "lessThan": "v6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w700_ieee_802.11n_family:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w700_ieee_802.11n_family", "vendor": "siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1748_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1748_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_1_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_1_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_eec_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_eec_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_w1788_2ia_m12:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_w1788_2ia_m12", "vendor": "siemens", "versions": [ { "lessThan": "v3.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x200_4p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x200_4p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt:0.0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalance_x201_3p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalance_x201_3p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x202_2p_irt:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x202_2p_irt", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_202_2p_irt_pro:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_202_2p_irt_pro", "vendor": "siemens", "versions": [ { "lessThan": "v5.5.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalancce_x204_2:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalancce_x204_2", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2fm:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2fm", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ld_ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ld_ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:siemens:scalence_x204_2ts:0:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "scalence_x204_2ts", "vendor": "siemens", "versions": [ { "lessThan": "v5.25", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2020-28400", "options": [ { "Exploitation": "none" }, { "Automatable": "yes" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-06-13T18:59:11.953107Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-24T18:07:44.485Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-04T16:33:59.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.7" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) EU", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "RUGGEDCOM RM1224 LTE(4G) NAM", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M804PB", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M812-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M816-1 ADSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M826-2 SHDSL-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-2", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M874-3 3G-Router (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-3 (ROK)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE M876-4 (NAM)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM853-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (A1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (B1)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (CN)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (EU)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE MUM856-1 (RoW)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 EEC LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE S615 LAN-Router", "vendor": "Siemens", "versions": [ { "lessThan": "V6.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 EEC M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W1788-2IA M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W721-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W722-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W734-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W738-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W748-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W761-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W774-1 RJ45 (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W778-1 M12 EEC (USA)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2 SFP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W786-2IA RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-1 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 M12 EEC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE W788-2 RJ45", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X200-4P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X201-3P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X202-2P IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2FM", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2LD TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204-2TS", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X204IRT PRO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X206-1LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X208PRO", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X212-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X216", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X224", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X302-7 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X304-2FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X306-1LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V, coated)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-2 EEC (2x 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X307-3LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LD", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2LH+", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X308-2M TS", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X310FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1 FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X320-1-2LD FE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE X408-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB205-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB208 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3 (ST, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB213-3LD (SC, PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (E/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XB216 (PN)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (SC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2 (ST/BFOC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2G PoE EEC (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G (EIP DEF.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC206-2SFP G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G (EIP def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC208G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-3G PoE (54 V DC)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G (EIP Def.)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XC224-4C G EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF201-3P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF202-2P IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204 DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA DNA", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204-2BA IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF204IRT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V5.5.0" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF206-1", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XF208", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.5", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM408-8C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XM416-4C (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP208PoE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216 (Ethernet/IP)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XP216POE EEC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-12M TS (24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (230V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE (24V, ports on rear)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 x FE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR324WG (24 X FE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR326-2C PoE WG (without UL)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, AC 230V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR328-4C WG (28xGE, DC 24V)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR524-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 1x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 24V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR526-8C, 2x230V (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR528-6M (L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2, L3 int.)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SCALANCE XR552-12M (2HR2)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CM 1542-1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1604", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1616", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CP 1626", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC IE/PB-LINK", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V3", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV540 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 H", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV550 S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 U", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MV560 X", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC NET DK-16xx PN IO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003e= V2.7" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Power Line Booster PLB, Base Module", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PROFINET Driver", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.3" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All Versions \u003c V4.5" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V1.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.1.3" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE X308-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.1.4", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC206-2SFP", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC208", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET SCALANCE XC216-4C", "vendor": "Siemens", "versions": [ { "lessThan": "V4.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SOFTNET-IE PNIO", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 8.7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-12-10T13:53:22.763Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-28400", "datePublished": "2021-07-13T11:02:49", "dateReserved": "2020-11-10T00:00:00", "dateUpdated": "2024-12-10T13:53:22.763Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2013-2780
Vulnerability from cvelistv5
Published
2013-04-22 01:00
Modified
2024-08-06 15:44
Severity ?
EPSS score ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T15:44:33.607Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2012-12-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-02-10T14:06:51", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2013-2780", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2013-2780", "datePublished": "2013-04-22T01:00:00", "dateReserved": "2013-04-11T00:00:00", "dateUpdated": "2024-08-06T15:44:33.607Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2012-3040
Vulnerability from cvelistv5
Published
2012-10-10 18:00
Modified
2024-08-06 19:50
Severity ?
EPSS score ?
Summary
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
References
▼ | URL | Tags |
---|---|---|
http://secunia.com/advisories/50816 | third-party-advisory, x_refsource_SECUNIA | |
http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf | x_refsource_MISC | |
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf | x_refsource_CONFIRM | |
http://osvdb.org/86130 | vdb-entry, x_refsource_OSVDB | |
http://en.securitylab.ru/lab/PT-2012-50 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.460Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "50816", "tags": [ "third-party-advisory", "x_refsource_SECUNIA", "x_transferred" ], "url": "http://secunia.com/advisories/50816" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf" }, { "name": "86130", "tags": [ "vdb-entry", "x_refsource_OSVDB", "x_transferred" ], "url": "http://osvdb.org/86130" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://en.securitylab.ru/lab/PT-2012-50" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2012-10-09T00:00:00", "descriptions": [ { "lang": "en", "value": "Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2013-02-02T10:00:00", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "name": "50816", "tags": [ "third-party-advisory", "x_refsource_SECUNIA" ], "url": "http://secunia.com/advisories/50816" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf" }, { "name": "86130", "tags": [ "vdb-entry", "x_refsource_OSVDB" ], "url": "http://osvdb.org/86130" }, { "tags": [ "x_refsource_MISC" ], "url": "http://en.securitylab.ru/lab/PT-2012-50" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3040", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "50816", "refsource": "SECUNIA", "url": "http://secunia.com/advisories/50816" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf" }, { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf" }, { "name": "86130", "refsource": "OSVDB", "url": "http://osvdb.org/86130" }, { "name": "http://en.securitylab.ru/lab/PT-2012-50", "refsource": "MISC", "url": "http://en.securitylab.ru/lab/PT-2012-50" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3040", "datePublished": "2012-10-10T18:00:00", "dateReserved": "2012-05-30T00:00:00", "dateUpdated": "2024-08-06T19:50:05.460Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2012-3037
Vulnerability from cvelistv5
Published
2012-09-25 10:00
Modified
2024-09-17 01:26
Severity ?
EPSS score ?
Summary
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf | x_refsource_CONFIRM | |
http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf | x_refsource_MISC | |
http://en.securitylab.ru/lab/PT-2012-48 | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.345Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://en.securitylab.ru/lab/PT-2012-48" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2012-09-25T10:00:00Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://en.securitylab.ru/lab/PT-2012-48" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3037", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf" }, { "name": "http://en.securitylab.ru/lab/PT-2012-48", "refsource": "MISC", "url": "http://en.securitylab.ru/lab/PT-2012-48" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3037", "datePublished": "2012-09-25T10:00:00Z", "dateReserved": "2012-05-30T00:00:00Z", "dateUpdated": "2024-09-17T01:26:53.895Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
Vulnerability from fkie_nvd
Published
2013-04-22 03:27
Modified
2024-11-21 01:52
Severity ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf | Broken Link, Vendor Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf | Broken Link, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1200_cpu_1211c_firmware | * | |
siemens | simatic_s7-1200_cpu_1211c | - | |
siemens | simatic_s7-1200_cpu_1212c_firmware | * | |
siemens | simatic_s7-1200_cpu_1212c | - | |
siemens | simatic_s7-1200_cpu_1212fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1212fc | - | |
siemens | simatic_s7-1200_cpu_1214_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1214_fc | - | |
siemens | simatic_s7-1200_cpu_1214c_firmware | * | |
siemens | simatic_s7-1200_cpu_1214c | - | |
siemens | simatic_s7-1200_cpu_1215_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1215_fc | - | |
siemens | simatic_s7-1200_cpu_1215c_firmware | * | |
siemens | simatic_s7-1200_cpu_1215c | - | |
siemens | simatic_s7-1200_cpu_1217c_firmware | * | |
siemens | simatic_s7-1200_cpu_1217c | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2A37383F-B3F7-423C-B956-87926E38B323", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3D4A8F2-6ACC-4809-8320-7A0305741069", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EBDF670-EA1F-45A4-8C2B-C52B5D2AF565", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EC634AF-318C-4280-B0E3-1DE20C98962C", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4A46E17-22DF-4FEB-B290-E209AF511B8E", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "233B1E82-769D-43AA-A051-CBAB0BD5F496", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CBD5520-7F19-44DE-AA9B-1D00475B987F", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E1B49EF-9276-47C7-ACE7-965B465BF202", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "919785E4-03B8-4BDF-9C3C-90538E24D13E", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port)." }, { "lang": "es", "value": "Siemens SIMATIC S7-1200 PLCs v2.x y v3.x permite a atacantes remotos causar una denegaci\u00f3n de servicio mediante paquetes especialmente creados hacia el puerto UDP 161 (puerto SNMP)" } ], "id": "CVE-2013-2780", "lastModified": "2024-11-21T01:52:21.247", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2013-04-22T03:27:13.063", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2012-10-10 18:55
Modified
2024-11-21 01:40
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://en.securitylab.ru/lab/PT-2012-50 | Third Party Advisory | |
ics-cert@hq.dhs.gov | http://osvdb.org/86130 | Broken Link | |
ics-cert@hq.dhs.gov | http://secunia.com/advisories/50816 | Third Party Advisory | |
ics-cert@hq.dhs.gov | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf | Broken Link, Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf | Broken Link, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://en.securitylab.ru/lab/PT-2012-50 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://osvdb.org/86130 | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://secunia.com/advisories/50816 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf | Broken Link, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf | Broken Link, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1200_cpu_1211c_firmware | * | |
siemens | simatic_s7-1200_cpu_1211c | - | |
siemens | simatic_s7-1200_cpu_1212c_firmware | * | |
siemens | simatic_s7-1200_cpu_1212c | - | |
siemens | simatic_s7-1200_cpu_1212fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1212fc | - | |
siemens | simatic_s7-1200_cpu_1214_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1214_fc | - | |
siemens | simatic_s7-1200_cpu_1214c_firmware | * | |
siemens | simatic_s7-1200_cpu_1214c | - | |
siemens | simatic_s7-1200_cpu_1215_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1215_fc | - | |
siemens | simatic_s7-1200_cpu_1215c_firmware | * | |
siemens | simatic_s7-1200_cpu_1215c | - | |
siemens | simatic_s7-1200_cpu_1217c_firmware | * | |
siemens | simatic_s7-1200_cpu_1217c | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1D6784CC-7FD8-4CD5-979F-0B9F62CE4AA3", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "90523ED2-CE36-4287-9D80-4A508DBD6E17", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0D31C744-AD8E-4E72-9E3E-F9ED8EFE2D8A", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E7EF332E-0725-44BB-8233-66B017D9DB20", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "30F62D4A-8014-4B82-B219-37385F902436", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "021DC100-8C4D-452B-93E1-952AD9DA0954", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6058C37-D10F-498B-80A6-E6608BCAF793", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8339C357-7788-4D44-9075-CA3FFB837453", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D1B4F7D-D7A6-4E79-9EE1-211394B37AA7", "versionEndExcluding": "3.0.2", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI." }, { "lang": "es", "value": "Vulnerabilidad de ejecuci\u00f3n de secuencias de comandos en sitios cruzados (XSS) en el servidor web SIMATIC S7-1200 PLCs v2.x hasta v3.0.1 permite a atacantes remotos inyectar secuencias de comandos web o HTML a trav\u00e9s de una URI espec\u00edficamente construida." } ], "id": "CVE-2012-3040", "lastModified": "2024-11-21T01:40:09.877", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "NONE", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": true } ] }, "published": "2012-10-10T18:55:02.080", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory" ], "url": "http://en.securitylab.ru/lab/PT-2012-50" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link" ], "url": "http://osvdb.org/86130" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory" ], "url": "http://secunia.com/advisories/50816" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Third Party Advisory", "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://en.securitylab.ru/lab/PT-2012-50" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "http://osvdb.org/86130" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://secunia.com/advisories/50816" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory", "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-79" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-07-13 11:15
Modified
2024-12-10 14:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-599968.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-599968.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 | Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | dk_standard_ethernet_controller_evaluation_kit_firmware | * | |
siemens | dk_standard_ethernet_controller_evaluation_kit | - | |
siemens | ek-ertec_200_evaulation_kit_firmware | * | |
siemens | ek-ertec_200_evaulation_kit | - | |
siemens | ek-ertec_200p_evaluation_kit_firmware | * | |
siemens | ek-ertec_200p_evaluation_kit | - | |
siemens | ruggedcom_rm1224_firmware | * | |
siemens | ruggedcom_rm1224 | - | |
siemens | scalance_m-800_firmware | * | |
siemens | scalance_m-800 | - | |
siemens | scalance_s615_firmware | * | |
siemens | scalance_s615 | - | |
siemens | scalance_w700_firmware | * | |
siemens | scalance_w700 | - | |
siemens | scalance_w1700_firmware | * | |
siemens | scalance_w1700 | - | |
siemens | scalance_x200-4_p_irt_firmware | * | |
siemens | scalance_x200-4_p_irt | - | |
siemens | scalance_x201-3p_irt_firmware | * | |
siemens | scalance_x201-3p_irt | - | |
siemens | scalance_x201-3p_irt_pro_firmware | * | |
siemens | scalance_x201-3p_irt_pro | - | |
siemens | scalance_x202-2_irt_firmware | * | |
siemens | scalance_x202-2_irt | - | |
siemens | scalance_x202-2p_irt_pro_firmware | * | |
siemens | scalance_x202-2p_irt_pro | - | |
siemens | scalance_x204_irt_firmware | * | |
siemens | scalance_x204_irt | - | |
siemens | scalance_x204_irt_pro_firmware | * | |
siemens | scalance_x204_irt_pro | - | |
siemens | scalance_x204-2_firmware | * | |
siemens | scalance_x204-2_ | - | |
siemens | scalance_x204-2fm_firmware | * | |
siemens | scalance_x204-2fm | - | |
siemens | scalance_x204-2ld_firmware | * | |
siemens | scalance_x204-2ld | - | |
siemens | scalance_x204-2ld_ts_firmware | * | |
siemens | scalance_x204-2ld_ts | - | |
siemens | scalance_x204-2ts_firmware | * | |
siemens | scalance_x204-2ts | - | |
siemens | scalance_x206-1_firmware | * | |
siemens | scalance_x206-1 | - | |
siemens | scalance_x206-1ld_firmware | * | |
siemens | scalance_x206-1ld | - | |
siemens | scalance_x208_firmware | * | |
siemens | scalance_x208 | - | |
siemens | scalance_x208pro_firmware | * | |
siemens | scalance_x208pro | - | |
siemens | scalance_x212-2_firmware | * | |
siemens | scalance_x212-2 | - | |
siemens | scalance_x212-2ld_firmware | * | |
siemens | scalance_x212-2ld | - | |
siemens | scalance_x216_firmware | * | |
siemens | scalance_x216 | - | |
siemens | scalance_x224_firmware | * | |
siemens | scalance_x224 | - | |
siemens | scalance_x302-7eec_firmware | * | |
siemens | scalance_x302-7eec | - | |
siemens | scalance_x304-2fe_firmware | * | |
siemens | scalance_x304-2fe | - | |
siemens | scalance_x306-1ldfe_firmware | * | |
siemens | scalance_x306-1ldfe | - | |
siemens | scalance_x307-2eec_firmware | * | |
siemens | scalance_x307-2eec | - | |
siemens | scalance_x307-3_firmware | * | |
siemens | scalance_x307-3 | - | |
siemens | scalance_x307-3ld_firmware | * | |
siemens | scalance_x307-3ld | - | |
siemens | scalance_x308-2_firmware | * | |
siemens | scalance_x308-2 | - | |
siemens | scalance_x308-2ld_firmware | * | |
siemens | scalance_x308-2ld | - | |
siemens | scalance_x308-2lh_firmware | * | |
siemens | scalance_x308-2lh | - | |
siemens | scalance_x308-2lh\+_firmware | * | |
siemens | scalance_x308-2lh\+ | - | |
siemens | scalance_x308-2m_firmware | * | |
siemens | scalance_x308-2m | - | |
siemens | scalance_x308-2m_poe_firmware | * | |
siemens | scalance_x308-2m_poe | - | |
siemens | scalance_x308-2m_ts_firmware | * | |
siemens | scalance_x308-2m_ts | - | |
siemens | scalance_x310_firmware | * | |
siemens | scalance_x310 | - | |
siemens | scalance_x310fe_firmware | * | |
siemens | scalance_x310fe | - | |
siemens | scalance_x320-1fe_firmware | * | |
siemens | scalance_x320-1fe | - | |
siemens | scalance_x320-3ldfe_firmware | * | |
siemens | scalance_x320-3ldfe | - | |
siemens | scalance_xb-200_firmware | * | |
siemens | scalance_xb-200 | - | |
siemens | scalance_xc-200_firmware | * | |
siemens | scalance_xc-200 | - | |
siemens | scalance_xf201-3p_irt_firmware | * | |
siemens | scalance_xf201-3p_irt | - | |
siemens | scalance_xf202-2p_irt_firmware | * | |
siemens | scalance_xf202-2p_irt | - | |
siemens | scalance_xf204_firmware | * | |
siemens | scalance_xf204 | - | |
siemens | scalance_xf204_irt_firmware | * | |
siemens | scalance_xf204_irt | - | |
siemens | scalance_xf204-2_firmware | * | |
siemens | scalance_xf204-2_ | - | |
siemens | scalance_xf204-2ba_irt_firmware | * | |
siemens | scalance_xf204-2ba_irt | - | |
siemens | scalance_xf206-1_firmware | * | |
siemens | scalance_xf206-1 | - | |
siemens | scalance_xf208_firmware | * | |
siemens | scalance_xf208 | - | |
siemens | scalance_xf-200ba_firmware | * | |
siemens | scalance_xf-200ba | - | |
siemens | scalance_xm400_firmware | * | |
siemens | scalance_xm400 | - | |
siemens | scalance_xp-200_firmware | * | |
siemens | scalance_xp-200 | - | |
siemens | scalance_xr324-4m_eec_firmware | * | |
siemens | scalance_xr324-4m_eec | - | |
siemens | scalance_xr324-4m_poe_firmware | * | |
siemens | scalance_xr324-4m_poe | - | |
siemens | scalance_xr324-4m_poe_ts_firmware | * | |
siemens | scalance_xr324-4m_poe_ts | - | |
siemens | scalance_xr324-12m_firmware | * | |
siemens | scalance_xr324-12m | - | |
siemens | scalance_xr324-12m_ts_firmware | * | |
siemens | scalance_xr324-12m_ts | - | |
siemens | scalance_xr500_firmware | * | |
siemens | scalance_xr500 | - | |
siemens | scalance_xr-300wg_firmware | * | |
siemens | scalance_xr-300wg | - | |
siemens | simatic_cfu_pa_firmware | * | |
siemens | simatic_cfu_pa | - | |
siemens | simatic_ie\/pb-link_v3_firmware | * | |
siemens | simatic_ie\/pb-link_v3 | - | |
siemens | simatic_mv500_firmware | * | |
siemens | simatic_mv500 | - | |
siemens | simatic_net_cm_1542-1_firmware | * | |
siemens | simatic_net_cm_1542-1 | - | |
siemens | simatic_net_cp1616_firmware | * | |
siemens | simatic_net_cp1616 | - | |
siemens | simatic_net_cp1604_firmware | * | |
siemens | simatic_net_cp1604 | - | |
siemens | simatic_net_cp1626_firmware | * | |
siemens | simatic_net_cp1626 | - | |
siemens | simatic_net_dk-16xx_pn_io | * | |
siemens | simatic_power_line_booster_plb_firmware | * | |
siemens | simatic_power_line_booster_plb | - | |
siemens | simatic_profinet_driver_firmware | * | |
siemens | simatic_profinet_driver | - | |
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simocode_prov_ethernet\/ip_firmware | * | |
siemens | simocode_prov_ethernet\/ip | - | |
siemens | simocode_prov_profinet_firmware | * | |
siemens | simocode_prov_profinet | - | |
siemens | softnet-ie_pnio_firmware | * | |
siemens | softnet-ie_pnio | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_evaluation_kit_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1BA1C1FD-EF49-488E-AB49-6F571D9E21B0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller_evaluation_kit:-:*:*:*:*:*:*:*", "matchCriteriaId": "83110E06-CDB2-49AE-B1E6-6785E0801A53", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_evaulation_kit_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "978998A4-C7B5-4D6D-9FAD-3C6F975C8881", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200_evaulation_kit:-:*:*:*:*:*:*:*", "matchCriteriaId": "12C60870-6B8C-4E91-B156-60D87B85543F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_evaluation_kit_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "249935E8-C45B-4586-B6BA-664AF23C7468", "versionEndExcluding": "4.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_evaluation_kit:-:*:*:*:*:*:*:*", "matchCriteriaId": "37176F8D-F1CB-4792-86FF-DA0FF674E0B8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ruggedcom_rm1224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "758CC5D1-F26C-4093-BE09-0583F4CDBBDB", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ruggedcom_rm1224:-:*:*:*:*:*:*:*", "matchCriteriaId": "284DF779-D900-48B4-A177-7281CD445AB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02BC878B-BF73-4A2C-A9D5-F9FF0F3D418B", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4F5AD34D-61AA-47B0-993A-4834984893EA", "versionEndExcluding": "6.4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F60CB864-640E-4BC2-B378-5AF3DCA292D4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44B0E5EA-4924-4865-AE6F-2F7BFCE5513B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*", "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200-4_p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8FCE9120-8091-41EC-A75E-01ED4AF64E28", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200-4_p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "73E42E20-18CB-40A7-B6D5-751F26303995", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EA86FF0D-7B16-4991-B4A5-AF33BF40693A", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "3268CF75-6DAB-416A-B19B-2A8F95C268CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA2326FF-5125-44F5-871C-2DC505E2B299", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "492E8AC1-338B-4AC3-90C7-1FADCD4528C4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x202-2_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A12E0F8-A7BB-48E9-98E5-7DA4962FA8AE", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x202-2_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "577D1E21-717C-4508-AE91-0BC490C89F85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "29C03AD0-7A60-4BFB-A0D3-BABB9717F1A1", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "F4726901-34BF-4F70-80A6-71648A4A29FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "576A1BD5-84DE-4FFC-926D-6C40E5176660", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "0BC31F0E-389B-4925-88DE-726F2F0D2A23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204_irt_pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AFE2ABF4-2996-4671-A5AF-4424FB2537C1", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204_irt_pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FF096BA-A6F4-46B3-9B9B-7FCEE7E6A6C3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "ACE1A821-8F0A-4B96-AC8A-B219215014B1", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2_:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AA16CFF-C01A-4AC0-A20E-50CBD3AA1C3E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54201E08-15E3-4C93-9A0D-DC376B7C8D88", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*", "matchCriteriaId": "1FCBC784-8EA0-4C6C-B504-DFC164028E4B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "75220631-DD7D-4E86-8405-F98340FFE27C", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "2BE27611-53E7-4162-8630-5BC334B02E37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3032A499-DFD5-4FEA-8AC6-E661781387AB", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "1FDEBD6B-6BE4-4FAD-A4E6-BE762595434D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A493C49A-8BF9-43E5-98D5-55E5390A36A5", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5FFC1E9-4326-4F41-A86A-C52AB6A9A674", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E2C9747F-BEC3-486E-B553-3339F8B54C3A", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "0A5BB0F2-DD4C-4AB4-9B8F-B2501B239080", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C8D68AC-8F30-4919-ADB3-A6018458602B", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DFF7FB7-774B-45ED-8400-951230DF0511", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2BC1450A-92ED-451F-9890-4E18CA974485", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*", "matchCriteriaId": "B3B574E2-F7BA-496B-887C-D25F386AA5E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "768320F0-10F5-4B36-AEB6-9DEEA43A30E8", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "DF2C60CF-4089-4993-A2CB-B7FBDAF81D62", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31B8367C-5EAC-49F4-83B8-C7E3BD373092", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "4E716A4E-50A9-4C52-8DA9-098F7506F4B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55F50ABF-3E9A-4435-BAA4-7D11A2047D46", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "C08CDEE3-43EB-475E-8571-6E12824714FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BC643617-D0B7-4379-8ADB-2C2BACA4B165", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0C4BAB5-E161-4B59-8A8C-369C7852A66E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F0189DF6-DA80-49FE-B09F-0C07D892518E", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*", "matchCriteriaId": "D2203895-BC4E-4B2F-9110-C2CD88A121F2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x302-7eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EF92A1A7-ADFB-49E1-AC54-03E32ECB73CE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x302-7eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8E97B3B-1808-45D2-97B7-CF31CA6E7A60", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x304-2fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "392D0623-343D-4BF1-BE0B-F2B347A24B62", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x304-2fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "0087A1C6-AA76-4FD6-BAA1-D3190D2A0116", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x306-1ldfe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "663897D9-82F5-436D-A0CF-BBB9338BF363", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x306-1ldfe:-:*:*:*:*:*:*:*", "matchCriteriaId": "880CF41B-B25D-4744-8E8B-C4B131932B1B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-2eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9666E7EA-A298-4972-80F8-765B0F99EB25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-2eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "804EE08B-75A1-4CF6-9C30-8CF0CDC39658", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9676DB10-982D-445F-9779-B39AE720AF2F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "55EF0738-C9EF-4E4B-A7E7-ECC1B5F0678A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x307-3ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "48D3EB09-6069-4289-A61E-C15B044EA2E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x307-3ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "7737F0C2-43FC-4330-88F2-9B08BA5B35D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F045D6B1-459B-46F0-86DF-F9AA3CCEA9BD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CCED3E4-38EF-4645-B25C-4F2C3D4E091C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2ld_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "40A1A5F9-4971-4E9D-BBE7-5A0357C56213", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2ld:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE1909FA-C8C6-46BE-83C6-2635D36FE69B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F53C74B-2154-417E-ACFE-01F0BACD3F15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh:-:*:*:*:*:*:*:*", "matchCriteriaId": "6DDBD94D-5312-4A54-AF76-D9DF791C0292", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2lh\\+_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D76A2268-5397-466C-98B5-01B46B4840A1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2lh\\+:-:*:*:*:*:*:*:*", "matchCriteriaId": "85153EED-C677-495D-A6BB-72365DE1ED3F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2F8888A7-3285-4ACA-A5AD-2B0578050C4C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*", "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_poe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C08597D-6190-4C73-9ECF-2535553DECAA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_poe:-:*:*:*:*:*:*:*", "matchCriteriaId": "3E22C57C-2BD6-4C39-93D2-5D81A58EA6F0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x308-2m_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A2C12934-E79C-41A4-B023-BADD7D68CB55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x308-2m_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFCCB68C-A58D-4543-A11F-721B01FFBBA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x310_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D288227C-69C1-4248-AB4A-51F44A41FDEA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x310:-:*:*:*:*:*:*:*", "matchCriteriaId": "7FE3716E-1C0A-4B72-809A-8318E5853FB1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x310fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27F765CD-B8A9-45B6-BA3C-C569FF0F8FF0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x310fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "8FB34E83-83A3-45C3-B040-D8910971D439", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x320-1fe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "91EDD23A-1DBD-4117-9396-89ADBC705B3A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x320-1fe:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC54880F-CBF4-4772-A4FB-B07D97287D44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x320-3ldfe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF07B014-1BA3-477E-A405-5DB35F68126A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x320-3ldfe:-:*:*:*:*:*:*:*", "matchCriteriaId": "80502856-7617-4ED9-A103-681021131EE0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B5557DB0-D3D8-4E53-BBA8-700B2BC336C0", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "41614C70-97B4-44C8-A441-530A413A26F9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1A7EDE9-B5F9-4471-8C5D-B1D590CB85FB", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "6751FB7D-C72C-4321-B535-5880FE696FC3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8CD13707-1164-415E-9083-7946D151F1FC", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*", "matchCriteriaId": "0F1AE867-67B4-4871-BF56-88017533A737", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "86FBD0DA-ADA4-4F06-A2D6-11D7312257A2", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "25DDF1EB-80E7-491F-A197-1B220E35CDF1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A09FF2D-F369-47B5-AEE4-A862BEDD9851", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204-2_:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C4207E0-7678-4E35-A79E-A6066D1E8BB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "786738CF-CA6C-4812-BD4D-595E249BFA76", "versionEndExcluding": "5.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "99E6AFAA-B903-47BB-B0F3-7650B039C0FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFCDC84E-0695-409A-844B-D24024CC33F2", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "2B40D2EB-5C69-47FA-801B-DC48407D418C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1DB6C03-71BF-4359-834B-384E78910E64", "versionEndExcluding": "5.2.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*", "matchCriteriaId": "898613B2-4A9D-44B9-A3FC-4347A2AD7CAB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*", "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D589735-017F-4675-8056-CA4FE57360E8", "versionEndExcluding": "6.3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_eec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1E6AB4BE-D669-4A95-8F8A-F2DA146D5FB1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_eec:-:*:*:*:*:*:*:*", "matchCriteriaId": "6F952542-6B79-4681-A236-15C188AAEB1E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1F4B8E2B-DEFF-4F1C-B5A4-0C4671C605C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe:-:*:*:*:*:*:*:*", "matchCriteriaId": "664D9C76-BC13-4874-939C-A8211DA33903", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-4m_poe_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9F4DE2B7-1AB3-4BA5-B261-926B774B01DD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-4m_poe_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "4834A67B-7B0B-4F88-BBFB-25667FD68EC5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0AC751E0-FC87-4DEB-85E8-C3E028B76482", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m:-:*:*:*:*:*:*:*", "matchCriteriaId": "36C9AE74-4683-4ED0-A605-3A6B065C230E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr324-12m_ts_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EB09860F-9DC8-476B-9AF7-6FFE57101D6C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr324-12m_ts:-:*:*:*:*:*:*:*", "matchCriteriaId": "4356417E-B4CB-45B0-B395-CE9D423FAB44", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32E2B545-326C-4724-90BC-147B57A37F20", "versionEndExcluding": "6.3.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4", "versionEndExcluding": "4.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*", "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A5119182-CB31-466A-AB0F-7956C8B45AE0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*", "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_ie\\/pb-link_v3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9A8C0F9C-AF27-424C-83F0-326EC10C40BE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_ie\\/pb-link_v3:-:*:*:*:*:*:*:*", "matchCriteriaId": "939D9324-2A7F-4DBF-8F9F-DB8A379C977A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CDEAC63C-E402-4698-B4A8-E9B53D5540DA", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*", "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cm_1542-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "761C2EC9-51B9-482B-8798-7982D265933D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cm_1542-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "40757A32-7347-4975-BC01-A1B28760D2C3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1616_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4575EFA7-C453-466D-9C37-38FEE0B78053", "versionEndIncluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "0B971242-13BA-4217-8FB0-92ACDCE463CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1604_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C9F73267-3A7A-4A38-B999-9877B173B518", "versionEndIncluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "A0DB421E-A774-451F-85AB-E66A4FAA33A6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_net_cp1626_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18143A38-84B8-479E-99FB-93FCA8CB058D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_net_cp1626:-:*:*:*:*:*:*:*", "matchCriteriaId": "5B0286CB-0566-4306-B069-789E5A4F168F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_net_dk-16xx_pn_io:*:*:*:*:*:*:*:*", "matchCriteriaId": "78430123-6230-4B76-B163-CDA3FA77413C", "versionEndIncluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_power_line_booster_plb_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2AAAECA7-6936-48AD-B617-79F4C708E47F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_power_line_booster_plb:-:*:*:*:*:*:*:*", "matchCriteriaId": "B7B52AEC-7A90-49F2-8006-FC146405C3E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE64639F-FC6D-43F6-A300-9B5A62495B27", "versionEndExcluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*", "matchCriteriaId": "526493E9-EF74-4836-9A8F-134B625035AA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6870C5CC-B7E0-45C3-9D98-F90765EE153F", "versionEndExcluding": "4.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_prov_ethernet\\/ip_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FBDC4FD6-06A6-4728-B8A0-D896CD89FD3E", "versionEndExcluding": "1.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_prov_ethernet\\/ip:-:*:*:*:*:*:*:*", "matchCriteriaId": "6CBAF8CF-6159-46D2-AB92-7CB5BFA7467B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_prov_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "27AC468E-63F9-443B-906C-D1794B846744", "versionEndExcluding": "2.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_prov_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "E595680D-555C-4A8E-A409-88CBCE6681E6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:softnet-ie_pnio_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45650D6F-1F5F-4DC8-BF5C-C4FBE3D3E39D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:softnet-ie_pnio:-:*:*:*:*:*:*:*", "matchCriteriaId": "B8673C81-91F5-4E74-8C5F-829040F39E0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device." }, { "lang": "es", "value": "Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condici\u00f3n de denegaci\u00f3n de servicio. La vulnerabilidad puede activarse si se env\u00eda una gran cantidad de paquetes de restablecimiento de DCP al dispositivo" } ], "id": "CVE-2020-28400", "lastModified": "2024-12-10T14:15:19.373", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2021-07-13T11:15:08.960", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-599968.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-05-11 10:29
Modified
2024-11-21 03:23
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
productcert@siemens.com | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf | Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_343-1_std_firmware | * | |
siemens | simatic_cp_343-1_std | - | |
siemens | simatic_cp_343-1_lean_firmware | * | |
siemens | simatic_cp_343-1_lean | - | |
siemens | simatic_cp_343-1_adv_firmware | * | |
siemens | simatic_cp_343-1_adv | - | |
siemens | simatic_cp_443-1_std_firmware | * | |
siemens | simatic_cp_443-1_std | - | |
siemens | simatic_cp_443-1_adv_firmware | * | |
siemens | simatic_cp_443-1_adv | - | |
siemens | simatic_cp_443-1_opc-ua_firmware | * | |
siemens | simatic_cp_443-1_opc-ua | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cm_1542-1_firmware | * | |
siemens | simatic_cm_1542-1 | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_1543-1_firmware | * | |
siemens | simatic_cp_1543-1 | - | |
siemens | simatic_rf650r_firmware | * | |
siemens | simatic_rf650r | - | |
siemens | simatic_rf680r_firmware | * | |
siemens | simatic_rf680r | - | |
siemens | simatic_rf685r_firmware | * | |
siemens | simatic_rf685r | - | |
siemens | simatic_cp_1616_firmware | * | |
siemens | simatic_cp_1616 | - | |
siemens | simatic_cp_1604_firmware | * | |
siemens | simatic_cp_1604 | - | |
siemens | simatic_dk-16xx_pn_io_firmware | * | |
siemens | simatic_dk-16xx_pn_io | - | |
siemens | scalance_x200_firmware | * | |
siemens | scalance_x200 | - | |
siemens | scalance_x200_irt_firmware | * | |
siemens | scalance_x200_irt | - | |
siemens | scalance_x300_firmware | * | |
siemens | scalance_x300 | - | |
siemens | scalance_x408_firmware | * | |
siemens | scalance_x408 | - | |
siemens | scalance_x414_firmware | * | |
siemens | scalance_x414 | - | |
siemens | scalance_xm400_firmware | * | |
siemens | scalance_xm400 | - | |
siemens | scalance_xr500_firmware | * | |
siemens | scalance_xr500 | - | |
siemens | scalance_w700_firmware | * | |
siemens | scalance_w700 | - | |
siemens | scalance_m-800_firmware | * | |
siemens | scalance_m-800 | - | |
siemens | scalance_s615_firmware | * | |
siemens | scalance_s615 | - | |
siemens | softnet_profinet_io_firmware | * | |
siemens | softnet_profinet_io_firmware | 14 | |
siemens | softnet_profinet_io | - | |
siemens | ie\/pb-link_firmware | * | |
siemens | ie\/pb-link | - | |
siemens | ie\/as-i_link_pn_io_firmware | * | |
siemens | ie\/as-i_link_pn_io | - | |
siemens | simatic_teleservice_adapter_standard_modem_firmware | * | |
siemens | simatic_teleservice_adapter_standard_modem | - | |
siemens | simatic_teleservice_adapter_ie_basic_modem_firmware | * | |
siemens | simatic_teleservice_adapter_ie_basic_modem | - | |
siemens | simatic_teleservice_adapter_ie_advanced_modem_firmware | * | |
siemens | simatic_teleservice_adapter_ie_advanced_modem | - | |
siemens | sitop_psu8600_firmware | * | |
siemens | sitop_psu8600 | - | |
siemens | ups1600_profinet_firmware | * | |
siemens | ups1600_profinet | - | |
siemens | simatic_et_200al_firmware | * | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_firmware | * | |
siemens | simatic_et_200mp | - | |
siemens | simatic_et_200pro_firmware | * | |
siemens | simatic_et_200pro | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_firmware | * | |
siemens | simatic_et_200sp | - | |
siemens | pn\/pn_coupler_firmware | * | |
siemens | pn\/pn_coupler | - | |
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller_firmware | 4.1.1 | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200p_pn_io_firmware | * | |
siemens | ek-ertec_200p_pn_io_firmware | 4.4.0 | |
siemens | ek-ertec_200p_pn_io | - | |
siemens | ek-ertec_200_pn_io_firmware | * | |
siemens | ek-ertec_200_pn_io_firmware | 4.2.1 | |
siemens | ek-ertec_200_pn_io | - | |
siemens | simatic_s7-200_smart_firmware | * | |
siemens | simatic_s7-200_smart | - | |
siemens | simatic_s7-300_firmware | * | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-400_firmware | * | |
siemens | simatic_s7-400 | - | |
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx_firmware | 2010 | |
siemens | simatic_winac_rtx | - | |
siemens | sirius_act_3su1_firmware | * | |
siemens | sirius_act_3su1 | - | |
siemens | sirius_soft_starter_3rw44_pn_firmware | * | |
siemens | sirius_soft_starter_3rw44_pn | - | |
siemens | sirius_motor_starter_m200d_profinet_firmware | * | |
siemens | sirius_motor_starter_m200d_profinet | - | |
siemens | simocode_pro_v_profinet_firmware | * | |
siemens | simocode_pro_v_profinet | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.4 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp_firmware | 1.2 | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120\(c\/p\/d\)_pn_firmware | * | |
siemens | sinamics_g120\(c\/p\/d\)_pn | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 4.7 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150_firmware | 4.7 | |
siemens | sinamics_g150 | - | |
siemens | sinamics_s110_pn_firmware | * | |
siemens | sinamics_s110_pn_firmware | 4.4 | |
siemens | sinamics_s110_pn | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 4.7 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 4.7 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_v90_pn_firmware | * | |
siemens | sinamics_v90_pn | - | |
siemens | simotion_firmware | * | |
siemens | simotion_firmware | 4.5 | |
siemens | simotion | - | |
siemens | sinumerik_828d_firmware | * | |
siemens | sinumerik_828d_firmware | 4.5 | |
siemens | sinumerik_828d | - | |
siemens | sinumerik_840d_sl_firmware | * | |
siemens | sinumerik_840d_sl_firmware | 4.5 | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_hmi_comfort_panels | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_multi_panels | * | |
siemens | simatic_hmi_multi_panels | - | |
siemens | simatic_hmi_mobile_panels | * | |
siemens | simatic_hmi_mobile_panels | - | |
siemens | simatic_cp_1243-1_irc_firmware | * | |
siemens | simatic_cp_1243-1_irc | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_cm_1542sp-1_firmware | * | |
siemens | simatic_cm_1542sp-1 | - | |
siemens | simatic_s7-1500_software_controller | * | |
siemens | sinumerik_828d_firmware | * | |
siemens | sinumerik_828d_firmware | 4.7 | |
siemens | sinumerik_828d | - | |
siemens | sinumerik_840d_sl_firmware | * | |
siemens | sinumerik_840d_sl_firmware | 4.7 | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_tdc_cpu555_firmware | * | |
siemens | simatic_tdc_cpu555 | - | |
siemens | simatic_tdc_cp51m1_firmware | * | |
siemens | simatic_tdc_cp51m1 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFF143FA-311E-4081-805F-BBDB72003556", "versionEndExcluding": "3.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C351559-6D8D-4EA8-87D6-83003844BD97", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A", "versionEndExcluding": "3.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E0622A2-C918-4062-938A-8736469F8286", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*", "matchCriteriaId": "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481", "versionEndExcluding": "3.2.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*", "matchCriteriaId": "BB8C873A-25EB-4787-9F25-DC5852337093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58E4035F-02AB-4B6D-A9AF-556DBE021C30", "versionEndExcluding": "3.2.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*", "matchCriteriaId": "75013961-5B00-42E9-9061-CF2E9A4FC090", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*", "matchCriteriaId": "977E97C8-959F-4146-8BFD-0FCF014B1534", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBE1A019-4BC4-4352-BA16-05629A20F89F", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA3E3782-7F36-4BC3-8D00-E1961E3105E3", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "496E9B17-BD29-4DE9-96B3-B23E3599C766", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12F7A42E-4D63-4A2A-ABF6-CA08BB6C6234", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "37B4E3A9-FE27-4A31-A213-92B461A5C846", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*", "matchCriteriaId": "C82C2C69-D983-4317-968B-D1855DF8AE43", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "177A6E55-8D64-4CB8-B366-AE272E715932", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*", "matchCriteriaId": "450DE127-DFED-4799-B8EA-0F95028E4BC3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72D14DB5-6132-4442-8AB2-3ECE89B1D47C", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*", "matchCriteriaId": "63F70060-0090-4BD7-8BF6-769989879ACD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0424AECD-68D5-45F1-9F55-B72CB4DFE39C", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_dk-16xx_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "26113F2F-8C5E-471B-9E12-AA3B3860B5CF", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_dk-16xx_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA0D867D-737F-4CEC-BAEA-9ADE0BA2303E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45008AE8-8386-4CBA-8C38-10C1A60150C2", "versionEndExcluding": "5.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*", "matchCriteriaId": "A59C91EA-5D1B-4970-8C36-BD76BA420B12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F61995A-2018-4DAA-9529-BADC145B267F", "versionEndExcluding": "5.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "CAF3DA7A-6B80-4F20-835F-BF071197D1B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3", "versionEndExcluding": "4.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3F6299B-D7E3-4750-B016-7DCBC83C2287", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8A4CF89-9DDA-4974-A886-CC0A912017F7", "versionEndExcluding": "4.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*", "matchCriteriaId": "47F713E4-4B75-476E-BC21-92CA10198AE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2CA7C987-779A-4B64-BFAC-73D54618AF04", "versionEndExcluding": "3.10.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA", "versionEndExcluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B9AF696-211F-4CAD-8A0E-402487E8DC50", "versionEndExcluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8763BB9-5DDA-4817-BDA6-63983CD4BC67", "versionEndExcluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5", "versionEndExcluding": "4.03", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE", "versionEndExcluding": "4.03", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9831567D-6528-4ACA-99F9-1EC42CB4A90D", "versionEndExcluding": "14", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*", "matchCriteriaId": "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "E348069A-B809-4DF6-81E9-DC52C6E2C268", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8ED91175-0AF3-424A-8C49-43587BB95EAB", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D43C16C-0719-4648-903F-6CC0FFF1835A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E909C1E-9329-4459-ACE3-AD906CD4A968", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "317863B6-0B71-4D03-83FE-FC59EBB5307C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_standard_modem_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9F37323-B072-470B-B770-9735B84CACFE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_standard_modem:-:*:*:*:*:*:*:*", "matchCriteriaId": "610DF0CA-D0FA-4CBE-8383-6F038E7AC4C3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_modem_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B366E4A-4223-4A42-9A05-52EB23BCF209", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic_modem:-:*:*:*:*:*:*:*", "matchCriteriaId": "98FB86B6-DB8A-42EF-BA60-68D96B6FE8B6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_modem_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7CD7CAEE-9C1A-4520-8F85-FD9BFB0A57D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF513598-C3FA-4555-8133-A7276DDAFAC8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC", "versionEndExcluding": "1.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E", "versionEndExcluding": "2.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "ECC84D6F-F5E0-47CF-B11E-1C43F866D972", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C9D0595-53CD-48C0-82E3-DB0B2EC17721", "versionEndExcluding": "1.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55BE63B0-F44E-4FCD-B00C-77595BACC62E", "versionEndExcluding": "4.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3237684A-3BEA-462F-A91D-ABC94C90D15A", "versionEndExcluding": "4.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32BD232D-A6BB-4D7B-BD00-1085D08D8A77", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0", "versionEndExcluding": "4.1.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*", "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9329BF4-D00A-4138-AA4C-93022002C0B9", "versionEndExcluding": "4.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*", "matchCriteriaId": "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "E62802E3-AFA3-4023-9671-95C220397956", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C46E084-9732-4920-86C2-3A91830CBCE3", "versionEndExcluding": "4.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*", "matchCriteriaId": "18C8B2FB-87C3-4DBB-9960-53FA545F26CB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5", "versionEndExcluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*", "matchCriteriaId": "598EEFC9-5240-4011-9017-A9557585AA19", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9461CADE-1624-4D1B-8CF2-CF65F75071C0", "versionEndExcluding": "3.3.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2570E321-C28E-46FA-8693-1230B3B5FD1B", "versionEndExcluding": "6.0.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "582B49BD-4565-4D19-BBE6-A193BDFCE8B0", "versionEndExcluding": "4.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D24953B-B3DF-4150-810C-64A94A55E829", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", "versionEndExcluding": "2010", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*", "matchCriteriaId": "8582A3E8-C05E-4D0B-851D-8C3181ED61CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F84A65E6-4672-4B62-826E-6FAAE0B4A89D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D42184E-8998-4C40-9612-5C9DE193CC06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "98FDB53A-8F5D-46AA-9366-F6480B12D744", "versionEndExcluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD2943F3-C46C-462E-9062-EE7B3E56CF72", "versionEndExcluding": "1.4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*", "matchCriteriaId": "975EFBBB-33E1-4D04-9E06-93553D45539C", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D7A7140-62A2-434F-AB79-1D47C918F1FE", "versionEndExcluding": "1.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*", "matchCriteriaId": "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21ED7835-5D9B-4AF0-8E71-A4E7377FAD9F", "versionEndExcluding": "4.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "64E77B7F-3E48-4C2C-9E2E-4AAEA6BCA71A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC731378-CB83-4C15-BC6A-5A86DF9B62F1", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "51A78A0B-5D75-418A-98AC-6EBF50D89A8A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "35B36BC1-EE75-48D5-B511-C79891DA0F86", "versionEndExcluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s110_pn_firmware:4.4:-:*:*:*:*:*:*", "matchCriteriaId": "8C21EF20-693C-425F-A370-E84722856212", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s110_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "A4D7197E-C921-42CA-BE43-C96A4223F443", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "772FF972-2193-4639-B454-F92762E49C39", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8EE54303-4FDA-42C7-B33B-BA884CD31339", "versionEndExcluding": "1.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "D870F289-F2BC-4105-A8F0-30E47CDE9FEF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "92A7198A-D6C5-4FBF-8860-5C8EA864718B", "versionEndExcluding": "4.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*", "matchCriteriaId": "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*", "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1", "versionEndExcluding": "4.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*", "matchCriteriaId": "AEB948AA-7BD7-4A0F-B86E-38ECD722C086", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28E3AB24-86B4-485D-8D3A-131E5C7F0108", "versionEndExcluding": "4.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*", "matchCriteriaId": "40AC387B-B799-4A34-8C9E-73D05B86801D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE53BC8E-CDA7-476A-87CA-532F365C79A7", "versionEndExcluding": "15.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1150AED-CDBE-492C-95FF-3E02B3B447F1", "versionEndExcluding": "15.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AAE6A83-737B-47A9-86BB-652C7F6A8013", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*", "matchCriteriaId": "42E8D21B-9CF4-4C2E-B33C-212BA29C7124", "versionEndExcluding": "15.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02610368-4B97-4B3F-8592-64CF8F65D8AD", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cm_1542sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8BF91884-7532-4E15-A754-EBC430FD0E9D", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cm_1542sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "921D7568-9FE9-4491-B099-A922984351DC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*", "matchCriteriaId": "64D5B21D-0DC1-479B-810B-21E78F34A80A", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45B42950-8BD9-4933-9615-27FCC67C03A1", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "86ADBE36-CC1F-4F3C-81CA-ABA0F40AC212", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6377EA6B-8EE3-4208-8FB0-175684A77B3F", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "D5AE6E9A-02B9-4A69-ACC4-EFBE1767E51E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642", "versionEndExcluding": "1.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B", "versionEndExcluding": "1.1.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*", "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected." }, { "lang": "es", "value": "Los paquetes PROFINET DCP especialmente dise\u00f1ados que se env\u00edan en un segmento Ethernet local (capa 2) a un producto afectado podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de ese producto. Se requiere la interacci\u00f3n humana para recuperar el sistema. Las interfaces PROFIBUS no est\u00e1n afectadas. Esta vulnerabilidad s\u00f3lo afecta a los SIMATIC HMI Multi Panels y HMI Mobile Panels, y a los dispositivos S7-300/S7-400" } ], "id": "CVE-2017-2681", "lastModified": "2024-11-21T03:23:57.917", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "ADJACENT", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2017-05-11T10:29:00.180", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98369" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securitytracker.com/id/1038463" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Broken Link" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98369" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securitytracker.com/id/1038463" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-12-26 04:29
Modified
2024-11-21 03:10
Severity ?
Summary
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-141614.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-346262.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | ||
productcert@siemens.com | https://www.securityfocus.com/bid/101964 | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-141614.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-346262.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | ||
af854a3a-2127-422b-91ae-364da2661108 | https://www.securityfocus.com/bid/101964 |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-200_firmware | * | |
siemens | simatic_s7-200 | - | |
siemens | simatic_s7-400pn_v6_firmware | * | |
siemens | simatic_s7-400pn_v6 | - | |
siemens | simatic_s7-400h_v6_firmware | * | |
siemens | simatic_s7-400h_v6 | - | |
siemens | simatic_s7-400pn\/dp_v7_firmware | - | |
siemens | simatic_s7-400pn\/dp_v7 | - | |
siemens | simatic_s7-410_v8_firmware | - | |
siemens | simatic_s7-410_v8 | - | |
siemens | simatic_s7-300_firmware | - | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-1200_firmware | - | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_s7-1500_controller_firmware | 2.0 | |
siemens | simatic_s7-1500_controller | - | |
siemens | simatic_winac_rtx_f_2010_firmware | - | |
siemens | simatic_winac_rtx_f_2010 | - | |
siemens | simatic_et_200al_firmware | - | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200ecopn_firmware | - | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200m_firmware | - | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_firmware | - | |
siemens | simatic_et_200mp | - | |
siemens | simatic_et_200pro_firmware | - | |
siemens | simatic_et_200pro | - | |
siemens | simatic_et_200s_firmware | - | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_firmware | - | |
siemens | simatic_et_200sp | - | |
siemens | dk_standard_ethernet_controller_firmware | - | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200p_firmware | * | |
siemens | ek-ertec_200p | - | |
siemens | ek-ertec_200pn_io_firmware | - | |
siemens | ek-ertec_200pn_io | - | |
siemens | simotion_d_firmware | * | |
siemens | simotion_d | - | |
siemens | simotion_c_firmware | * | |
siemens | simotion_c | - | |
siemens | simotion_p_firmware | * | |
siemens | simotion_p | - | |
siemens | sinamics_dcm_firmware | - | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | - | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m\/g120pn_firmware | * | |
siemens | sinamics_g110m\/g120pn | - | |
siemens | sinamics_g130_firmware | - | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | - | |
siemens | sinamics_g150 | - | |
siemens | sinamics_s110pn_firmware | - | |
siemens | sinamics_s110pn | - | |
siemens | sinamics_s120_firmware | - | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_v4.7_firmware | - | |
siemens | sinamics_s150_v4.7 | - | |
siemens | sinamics_s150_v4.8_firmware | - | |
siemens | sinamics_s150_v4.8 | - | |
siemens | sinamics_v90pn_firmware | - | |
siemens | sinamics_v90pn | - | |
siemens | sinumerik_840d_sl_firmware | - | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_compact_field_unit_firmware | - | |
siemens | simatic_compact_field_unit | - | |
siemens | simatic_pn\/pn_coupler_firmware | - | |
siemens | simatic_pn\/pn_coupler | - | |
siemens | simocode_pro_v_profinet_firmware | - | |
siemens | simocode_pro_v_profinet | - | |
siemens | sirius_soft_starter_3rw44pn_firmware | - | |
siemens | sirius_soft_starter_3rw44pn | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E1170E1-3978-4B26-AE20-0B2E8F4C379B", "versionEndExcluding": "2.03.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200:-:*:*:*:*:*:*:*", "matchCriteriaId": "BAD1D073-B29D-42CE-AF5E-B1AEF3DF09E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400pn_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9296EA6-7EB3-4661-9024-C5E435E5E5DF", "versionEndExcluding": "6.0.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400pn_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "FA55DDD2-92C5-4A73-A75D-F13A7B720A22", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0DF482D-78BF-418E-8299-45E7C11C0F64", "versionEndExcluding": "6.0.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29A41A6-33ED-4E2E-9613-13FF0A521C1A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400pn\\/dp_v7:-:*:*:*:*:*:*:*", "matchCriteriaId": "66E6070F-9180-4FBC-A0DB-6AC8C242CADA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7F211D16-8C72-4720-BD72-8273DB73BBA1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*", "matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C096137-C1E3-4D19-87A9-BEB7A081DD1E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "5187EF42-3E86-4C73-A435-E5D5710B6999", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32221F56-8BA2-4DAE-BBCB-B5EDC2813674", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_controller_firmware:2.0:*:*:*:*:*:*:*", "matchCriteriaId": "9C92AE0F-3688-4DE7-8805-8C2B7E57A97A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "5E324C78-6911-412E-87D4-36A5BCA856EC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_f_2010_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2EA451CA-78D2-46D8-A3BA-419ACCB2E9D9", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx_f_2010:-:*:*:*:*:*:*:*", "matchCriteriaId": "61527333-0741-42DE-9A68-BBC288526DD8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AD5A211-517E-40BE-B306-FE29F9CD3F67", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D281D261-AF1E-417B-9D86-2BC11B5D1231", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "D0BED0F6-86D0-43E0-AD49-F4F111245F39", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "DDF6E7E6-B323-4576-92AF-33FF3E5F3CE8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1BAFDDB1-7AF3-4665-B1AE-ED893245890A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C194763-8D3D-490D-BF6C-B881581BB13B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "238BF3F4-3680-4138-A1F0-4034A614A41B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "ED030D86-261F-446C-A7AA-1B2CD3C0BF09", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4EE8C83-8D16-447C-AF7C-4CF52438E932", "versionEndExcluding": "4.5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*", "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200pn_io_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "37947E71-645B-408D-B45B-A03214B46CEC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "36AA2F7C-ABCF-4F43-A595-49F8BDAD6336", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5532645E-7937-4B07-8DE1-5CA04A57A852", "versionEndIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion_d:-:*:*:*:*:*:*:*", "matchCriteriaId": "F736C6F1-98CE-4C94-9457-4E1278B66C05", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E5DFA690-68F5-461E-BD0E-E9813F0103D3", "versionEndIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion_c:-:*:*:*:*:*:*:*", "matchCriteriaId": "BA8EBFB0-47DE-495A-9971-B762BB519E0C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_p_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A71DD5C2-3127-48CC-A02E-3BD6C66DB8B3", "versionEndIncluding": "5.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion_p:-:*:*:*:*:*:*:*", "matchCriteriaId": "AA14B83E-1438-46B9-B05E-DB9165DF9274", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4004A6FB-C40C-484F-A0A2-485B6B617FF8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "713658D1-059F-478F-A950-3969EDD2EC6F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g110m\\/g120pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "22FF232D-AA38-481F-BA05-94BCD80A0E72", "versionEndIncluding": "4.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110m\\/g120pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "DAD9F256-8342-45D2-9758-C24484CBE19D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "2D52C517-17D7-467A-A021-9832DC8906F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF9EA116-C2EF-487F-A9CD-8526B014AA77", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s110pn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BFA2F893-58D9-4445-9653-564291014A54", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s110pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "763325DC-F62B-4F61-8A05-CA5C836EC990", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "CDA8B933-D7E3-4E3B-AA1D-75AFC89EA730", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_v4.7_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F961DB8C-4602-4B25-8CBC-F61413F48C40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150_v4.7:-:*:*:*:*:*:*:*", "matchCriteriaId": "E0D975BB-137E-415B-9D0A-C3B68C3FD16A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_v4.8_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "63DC04F5-D4C9-4FD7-BA26-ACD9B6B6E91B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150_v4.8:-:*:*:*:*:*:*:*", "matchCriteriaId": "90FA0B11-B161-4516-9D4F-9D3CEABB71BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_v90pn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "66B06805-BAAA-46A8-9FCD-03876ED5D079", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_v90pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0CB3D335-F7F5-4CEA-82E0-FF56762E984C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "705AA5C8-E884-479D-972E-C779B6D0542B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_compact_field_unit_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "B18BCB76-61B2-4573-8EBF-EB61B597B7E4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_compact_field_unit:-:*:*:*:*:*:*:*", "matchCriteriaId": "933FF731-95FA-4A32-80DC-47CD806144D0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "6086ACE6-B396-4954-80E8-EDD167DF2021", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*", "matchCriteriaId": "49FB85F8-7D45-433E-805B-360725F2980C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "BD292574-20C0-432B-8BE7-3893077DC3FD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44pn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "44C18078-18D3-445F-B67B-B21BE6B6A44B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "336625A5-CADB-4F33-B49F-ACA4D4B4EDEC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incluidas las variantes SIPLUS), SIMATIC ET200S (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incluidas las variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incluidas las variantes SIPLUS NET), familia SIMATIC S7-1200 CPU (incluidas las variantes SIPLUS), familia SIMATIC S7-1500 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, familia SIMATIC S7-300 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS), SIMATIC S7-400 H V6 CPU familia y posteriores (incluidas las variantes SIPLUS), SIMATIC S7-400 PN/DP V6 CPU familia y posteriores (incluidas las variantes SIPLUS), familia SIMATIC S7-400 PN/DP V7 CPU (incluidas las variantes SIPLUS), familia SIMATIC S7-410 V8 CPU (incluidas las variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incluidas las variantes SIPLUS), SIMOCODE pro V PN (incluidas las variantes SIPLUS), SIMOTION C, SIMOTION D (incluidas las variantes SIPLUS), SIMOTION D4xx V4.4 para SINAMICS SM150i-2 w. PROFINET (incluidas las variantes SIPLUS), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. PN, SINAMICS G110M w. PN, SINAMICS G120(C/P/D) w. PN (incluidas las variantes SIPLUS), SINAMICS G130 V4.7 w. PN, SINAMICS G130 V4.8 w. PN, SINAMICS G150 V4.7 w. PN, SINAMICS G150 V4.8 w. PN, SINAMICS GH150 V4.7 w. PROFINET, SINAMICS GL150 V4.7 w. PROFINET, SINAMICS GM150 V4.7 w. PROFINET, SINAMICS S110 w. PN, SINAMICS S120 V4.7 SP1 w. PN (incluidas las variantes SIPLUS), SINAMICS S120 V4.7 w. PN (incluidas las variantes SIPLUS), SINAMICS S120 V4.8 w. PN (incluidas las variantes SIPLUS), SINAMICS S120 prior to V4.7 w. PN (incluidas las variantes SIPLUS), SINAMICS S150 V4.7 w. PN, SINAMICS S150 V4.8 w. PN, SINAMICS SL150 V4.7.0 w. PROFINET, SINAMICS SL150 V4.7.4 w. PROFINET, SINAMICS SL150 V4.7.5 w. PROFINET, SINAMICS SM120 V4.7 w. PROFINET, SINAMICS V90 w. PN, SINUMERIK 840D sl, SIRIUS Soft Starter 3RW44 PN. Los paquetes especialmente creados enviados al puerto 161/UDP podr\u00edan generar una condici\u00f3n de denegaci\u00f3n de servicio. Los dispositivos afectados deben reiniciarse manualmente" } ], "id": "CVE-2017-12741", "lastModified": "2024-11-21T03:10:07.963", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 8.7, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2017-12-26T04:29:13.707", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "source": "productcert@siemens.com", "url": "https://www.securityfocus.com/bid/101964" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-141614.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-346262.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.securityfocus.com/bid/101964" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2018-12-13 16:29
Modified
2024-11-21 03:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/105928 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/105928 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_firmware | - | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "5187EF42-3E86-4C73-A435-E5D5710B6999", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F81F41D-480F-4443-927E-00607DD40BF5", "versionEndExcluding": "2.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions \u003c V2.6). An attacker could exhaust the available connection pool of an affected device by opening a sufficient number of connections to the device. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. The vulnerability, if exploited, could cause a Denial-of-Service condition impacting the availability of the system. At the time of advisory publication no public exploitation of this vulnerability was known." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC S7-1200 (todas las versiones) y SIMATIC S7-1500 (todas las versiones anteriores a la V2.6). Un atacante podr\u00eda agotar el grupo de conexiones disponibles de un dispositivo afectado abriendo un n\u00famero suficiente de conexiones al dispositivo. Su explotaci\u00f3n con \u00e9xito requiere que un atacante sea capaz de enviar paquetes al puerto 102/tcp del dispositivo afectado. No se requiere interacci\u00f3n o privilegios del usuario para explotar esta vulnerabilidad. Si se explota esta vulnerabilidad, se podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio (DoS) que impacta sobre la disponibilidad del sistema. En el momento de la publicaci\u00f3n del aviso, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad." } ], "id": "CVE-2018-13815", "lastModified": "2024-11-21T03:48:07.740", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2018-12-13T16:29:00.383", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105928" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/105928" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-584286.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-410" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2012-09-25 11:07
Modified
2024-11-21 01:40
Severity ?
Summary
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://en.securitylab.ru/lab/PT-2012-48 | Third Party Advisory | |
ics-cert@hq.dhs.gov | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf | Broken Link, Vendor Advisory | |
ics-cert@hq.dhs.gov | http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf | Broken Link, Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | http://en.securitylab.ru/lab/PT-2012-48 | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf | Broken Link, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf | Broken Link, Third Party Advisory, US Government Resource |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1200_cpu_1211c_firmware | * | |
siemens | simatic_s7-1200_cpu_1211c | - | |
siemens | simatic_s7-1200_cpu_1212c_firmware | * | |
siemens | simatic_s7-1200_cpu_1212c | - | |
siemens | simatic_s7-1200_cpu_1212fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1212fc | - | |
siemens | simatic_s7-1200_cpu_1214_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1214_fc | - | |
siemens | simatic_s7-1200_cpu_1214c_firmware | * | |
siemens | simatic_s7-1200_cpu_1214c | - | |
siemens | simatic_s7-1200_cpu_1215_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1215_fc | - | |
siemens | simatic_s7-1200_cpu_1215c_firmware | * | |
siemens | simatic_s7-1200_cpu_1215c | - | |
siemens | simatic_s7-1200_cpu_1217c_firmware | * | |
siemens | simatic_s7-1200_cpu_1217c | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "DBAF9260-5746-469B-AAB3-66F12108A610", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C1476AD3-CF60-462E-9EEF-616A1B510F88", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5A19DB02-8D64-4044-97BD-6769F3CE6AE5", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "406EC119-4B43-4AFD-9BC9-FE86E2F57F51", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3A162C46-AB20-41EB-B76F-799BCEAF66F9", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "82B37AFD-DCE1-4244-BB70-1DCDA91B82C1", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "147E133F-E99A-4DDA-A77B-E3EAC59AB2EE", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8861261D-7153-4D30-8614-BA67BB3888C0", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8F5277B1-273F-4138-9C29-D2E25C6C21F1", "versionEndExcluding": "3.0.0", "versionStartIncluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate." }, { "lang": "es", "value": "El PLC siemens SIMATIC S7-1200 2.x no protege de forma adecuada la clave privada del certificado de SIMATIC CONTROLLER Certification Authority, lo que permitir\u00eda a atacantes remotos espiar el servidor Web S7-1200 usando esta clave para crear certificados falsificados." } ], "id": "CVE-2012-3037", "lastModified": "2024-11-21T01:40:09.607", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2012-09-25T11:07:46.470", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory" ], "url": "http://en.securitylab.ru/lab/PT-2012-48" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Third Party Advisory", "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory" ], "url": "http://en.securitylab.ru/lab/PT-2012-48" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Third Party Advisory", "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-295" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2017-05-11 01:29
Modified
2024-11-21 03:23
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | Vendor Advisory | |
productcert@siemens.com | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | Third Party Advisory, US Government Resource | |
productcert@siemens.com | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | Broken Link | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securityfocus.com/bid/98369 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.securitytracker.com/id/1038463 | Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-284673.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-293562.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/html/ssa-546832.html | ||
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf | Broken Link |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_cp_343-1_std_firmware | * | |
siemens | simatic_cp_343-1_std | - | |
siemens | simatic_cp_343-1_lean_firmware | * | |
siemens | simatic_cp_343-1_lean | - | |
siemens | simatic_cp_343-1_adv_firmware | * | |
siemens | simatic_cp_343-1_adv | - | |
siemens | simatic_cp_443-1_std_firmware | * | |
siemens | simatic_cp_443-1_std | - | |
siemens | simatic_cp_443-1_adv_firmware | * | |
siemens | simatic_cp_443-1_adv | - | |
siemens | simatic_cp_443-1_opc-ua_firmware | * | |
siemens | simatic_cp_443-1_opc-ua | - | |
siemens | simatic_cp_1243-1_firmware | * | |
siemens | simatic_cp_1243-1 | - | |
siemens | simatic_cm_1542-1_firmware | * | |
siemens | simatic_cm_1542-1 | - | |
siemens | simatic_cp_1542sp-1_firmware | * | |
siemens | simatic_cp_1542sp-1 | - | |
siemens | simatic_cp_1542sp-1_irc_firmware | * | |
siemens | simatic_cp_1542sp-1_irc | - | |
siemens | simatic_cp_1543sp-1_firmware | * | |
siemens | simatic_cp_1543sp-1 | - | |
siemens | simatic_cp_1543-1_firmware | * | |
siemens | simatic_cp_1543-1 | - | |
siemens | simatic_rf650r_firmware | * | |
siemens | simatic_rf650r | - | |
siemens | simatic_rf680r_firmware | * | |
siemens | simatic_rf680r | - | |
siemens | simatic_rf685r_firmware | * | |
siemens | simatic_rf685r | - | |
siemens | simatic_cp_1616_firmware | * | |
siemens | simatic_cp_1616 | - | |
siemens | simatic_cp_1604_firmware | * | |
siemens | simatic_cp_1604 | - | |
siemens | simatic_dk-1616_pn_io_firmware | * | |
siemens | simatic_dk-1616_pn_io | - | |
siemens | scalance_x200_firmware | * | |
siemens | scalance_x200 | - | |
siemens | scalance_x200_irt_firmware | * | |
siemens | scalance_x200_irt | - | |
siemens | scalance_x300_firmware | * | |
siemens | scalance_x300 | - | |
siemens | scalance_x408_firmware | * | |
siemens | scalance_x408 | - | |
siemens | scalance_x414_firmware | * | |
siemens | scalance_x414 | - | |
siemens | scalance_xm400_firmware | * | |
siemens | scalance_xm400 | - | |
siemens | scalance_xr500_firmware | * | |
siemens | scalance_xr500 | - | |
siemens | scalance_w700_firmware | * | |
siemens | scalance_w700 | - | |
siemens | scalance_m-800_firmware | * | |
siemens | scalance_m-800 | - | |
siemens | scalance_s615_firmware | * | |
siemens | scalance_s615 | - | |
siemens | softnet_profinet_io_firmware | * | |
siemens | softnet_profinet_io_firmware | 14 | |
siemens | softnet_profinet_io | - | |
siemens | ie\/pb-link_firmware | * | |
siemens | ie\/pb-link | - | |
siemens | ie\/as-i_link_pn_io_firmware | * | |
siemens | ie\/as-i_link_pn_io | - | |
siemens | simatic_teleservice_adapter_ie_standard_firmware | * | |
siemens | simatic_teleservice_adapter_ie_standard | - | |
siemens | simatic_teleservice_adapter_ie_basic_firmware | * | |
siemens | simatic_teleservice_adapter_ie_basic | - | |
siemens | simatic_teleservice_adapter_ie_advanced_firmware | * | |
siemens | simatic_teleservice_adapter_ie_advanced_modem | - | |
siemens | sitop_psu8600_firmware | * | |
siemens | sitop_psu8600 | - | |
siemens | ups1600_profinet_firmware | * | |
siemens | ups1600_profinet | - | |
siemens | simatic_et_200al_firmware | * | |
siemens | simatic_et_200al | - | |
siemens | simatic_et_200ecopn_firmware | * | |
siemens | simatic_et_200ecopn | - | |
siemens | simatic_et_200m_firmware | * | |
siemens | simatic_et_200m | - | |
siemens | simatic_et_200mp_firmware | * | |
siemens | simatic_et_200mp | - | |
siemens | simatic_et_200pro_firmware | * | |
siemens | simatic_et_200pro | - | |
siemens | simatic_et_200s_firmware | * | |
siemens | simatic_et_200s | - | |
siemens | simatic_et_200sp_firmware | * | |
siemens | simatic_et_200sp | - | |
siemens | pn\/pn_coupler_firmware | * | |
siemens | pn\/pn_coupler | - | |
siemens | dk_standard_ethernet_controller_firmware | * | |
siemens | dk_standard_ethernet_controller_firmware | 4.1.1 | |
siemens | dk_standard_ethernet_controller | - | |
siemens | ek-ertec_200p_pn_io_firmware | * | |
siemens | ek-ertec_200p_pn_io_firmware | 4.4.0 | |
siemens | ek-ertec_200p_pn_io | - | |
siemens | ek-ertec_200_pn_io_firmware | * | |
siemens | ek-ertec_200_pn_io_firmware | 4.2.1 | |
siemens | ek-ertec_200_pn_io | - | |
siemens | simatic_s7-200_smart_firmware | * | |
siemens | simatic_s7-200_smart | - | |
siemens | simatic_s7-300_firmware | - | |
siemens | simatic_s7-300 | - | |
siemens | simatic_s7-400_firmware | * | |
siemens | simatic_s7-400 | - | |
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1500_firmware | * | |
siemens | simatic_s7-1500 | - | |
siemens | simatic_s7-1500_software_controller_firmware | * | |
siemens | simatic_s7-1500_software_controller | - | |
siemens | simatic_winac_rtx_firmware | * | |
siemens | simatic_winac_rtx_firmware | 2010 | |
siemens | simatic_winac_rtx | - | |
siemens | sirius_act_3su1_firmware | * | |
siemens | sirius_act_3su1 | - | |
siemens | sirius_soft_starter_3rw44_pn_firmware | * | |
siemens | sirius_soft_starter_3rw44_pn | - | |
siemens | sirius_motor_starter_m200d_profinet_firmware | * | |
siemens | sirius_motor_starter_m200d_profinet | - | |
siemens | simocode_pro_v_profinet_firmware | * | |
siemens | simocode_pro_v_profinet | - | |
siemens | sinamics_dcm_firmware | * | |
siemens | sinamics_dcm_firmware | 1.4 | |
siemens | sinamics_dcm_firmware | 1.4 | |
siemens | sinamics_dcm | - | |
siemens | sinamics_dcp_firmware | * | |
siemens | sinamics_dcp_firmware | 1.2 | |
siemens | sinamics_dcp | - | |
siemens | sinamics_g110m_firmware | * | |
siemens | sinamics_g110m_firmware | 4.7 | |
siemens | sinamics_g110m | - | |
siemens | sinamics_g120\(c\/p\/d\)_w._pn_firmware | * | |
siemens | sinamics_g120\(c\/p\/d\)_w._pn_firmware | 4.7 | |
siemens | sinamics_g120\(c\/p\/d\)_w._pn | - | |
siemens | sinamics_g130_firmware | * | |
siemens | sinamics_g130_firmware | 4.7 | |
siemens | sinamics_g130 | - | |
siemens | sinamics_g150_firmware | * | |
siemens | sinamics_g150_firmware | 4.7 | |
siemens | sinamics_g150 | - | |
siemens | sinamics__s110_pn_firmware | * | |
siemens | sinamics__s110_pn_firmware | 4.4 | |
siemens | _s110_pn | - | |
siemens | sinamics_s120_firmware | * | |
siemens | sinamics_s120_firmware | 4.7 | |
siemens | sinamics_s120 | - | |
siemens | sinamics_s150_firmware | * | |
siemens | sinamics_s150_firmware | 4.7 | |
siemens | sinamics_s150 | - | |
siemens | sinamics_v90_pn_firmware | * | |
siemens | sinamics_v90_pn | - | |
siemens | simotion_firmware | * | |
siemens | simotion_firmware | 4.5 | |
siemens | simotion | - | |
siemens | sinumerik_828d_firmware | * | |
siemens | sinumerik_828d_firmware | 4.5 | |
siemens | sinumerik_828d | - | |
siemens | sinumerik_840d_sl_firmware | * | |
siemens | sinumerik_840d_sl_firmware | 4.5 | |
siemens | sinumerik_840d_sl | - | |
siemens | simatic_hmi_comfort_panels | * | |
siemens | simatic_hmi_comfort_panels | - | |
siemens | simatic_hmi_multi_panels | * | |
siemens | simatic_hmi_multi_panels | - | |
siemens | simatic_hmi_mobile_panels | * | |
siemens | simatic_hmi_mobile_panels | - | |
siemens | simatic_cp_1243-1_irc_firmware | * | |
siemens | simatic_cp_1243-1_irc | - | |
siemens | simatic_cp_1243-1_iec_firmware | * | |
siemens | simatic_cp_1243-1_iec | - | |
siemens | simatic_cp_1243-1_dnp3_firmware | * | |
siemens | simatic_cp_1243-1_dnp3 | - | |
siemens | simatic_dk-1604_pn_io_firmware | * | |
siemens | simatic_dk-1604_pn_io | - | |
siemens | simatic_tdc_cpu555_firmware | * | |
siemens | simatic_tdc_cpu555 | - | |
siemens | simatic_tdc_cp51m1_firmware | * | |
siemens | simatic_tdc_cp51m1 | - | |
siemens | sinamics_gh150_firmware | * | |
siemens | sinamics_gh150_firmware | 4.7 | |
siemens | sinamics_gh150 | - | |
siemens | sinamics_gl150_firmware | * | |
siemens | sinamics_gl150_firmware | 4.8 | |
siemens | sinamics_gl150 | - | |
siemens | sinamics_gm150_firmware | * | |
siemens | sinamics_gm150_firmware | 4.7 | |
siemens | sinamics_gm150 | - | |
siemens | sinamics_sl150_firmware | * | |
siemens | sinamics_sl150_firmware | 4.8 | |
siemens | sinamics_sl150 | - | |
siemens | sinamics_sm120_firmware | * | |
siemens | sinamics_sm120_firmware | 4.8 | |
siemens | sinamics_sm120 | - | |
siemens | extension_unit_12_profinet_firmware | * | |
siemens | extension_unit_12_profinet | - | |
siemens | extension_unit_15_profinet_firmware | * | |
siemens | extension_unit_15_profinet | - | |
siemens | extension_unit_19_profinet_firmware | * | |
siemens | extension_unit_19_profinet | - | |
siemens | extension_unit_22_profinet_firmware | * | |
siemens | extension_unit_22_profinet | - | |
siemens | simatic_cp_1242-7_gprs_firmware | * | |
siemens | simatic_cp_1242-7_gprs | - | |
siemens | simatic_cp_1243-7_lte\/us_firmware | * | |
siemens | simatic_cp_1243-7_lte\/us | - | |
siemens | simatic_cp_1243-8_firmware | * | |
siemens | simatic_cp_1243-8 | - | |
siemens | simatic_cp_1626_firmware | * | |
siemens | simatic_cp_1626 | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFF143FA-311E-4081-805F-BBDB72003556", "versionEndExcluding": "3.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:*", "matchCriteriaId": "9C351559-6D8D-4EA8-87D6-83003844BD97", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47A5C59B-DAB3-4B05-B9FA-B75685F4AE2A", "versionEndExcluding": "3.1.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE2A18E2-F88F-4DC1-81E9-AC836C85A248", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E0622A2-C918-4062-938A-8736469F8286", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:*", "matchCriteriaId": "438184C5-3A2C-4DEE-8FF2-0EFBAA1BA37A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB8BECDB-D55A-4B74-ADEC-CDDBAC4E3481", "versionEndExcluding": "3.2.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:*", "matchCriteriaId": "BB8C873A-25EB-4787-9F25-DC5852337093", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "58E4035F-02AB-4B6D-A9AF-556DBE021C30", "versionEndExcluding": "3.2.17", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:*", "matchCriteriaId": "75013961-5B00-42E9-9061-CF2E9A4FC090", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32DC8BB2-9BC6-4CC2-9CF0-28DF8AEC595A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:*", "matchCriteriaId": "977E97C8-959F-4146-8BFD-0FCF014B1534", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EBE1A019-4BC4-4352-BA16-05629A20F89F", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA9BB25C-D5E3-43DE-8C73-06BDC43CA960", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6BE0A3E5-0069-4AD5-B287-88BE5D0291F1", "versionEndExcluding": "2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "FCB3A00F-252F-4E41-8254-6E8BBD40C4FD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "18B597C8-0401-458F-8DF9-062B5E833115", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "0C868560-8BAE-462D-AED0-3C52EA9B6DB8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6AF0B55-84D1-46FA-B3A1-81EB2E2FED18", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "E362CEA5-F47B-4294-8F2D-A0A7AC6FF390", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CA3E3782-7F36-4BC3-8D00-E1961E3105E3", "versionEndExcluding": "1.0.15", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "843A8686-5172-4782-BB97-B5D3C6FB27A3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "807D97E1-7680-4B8F-85AD-F56F039669D1", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "3FDE92FB-38C7-46E8-9208-BBD7872219D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "37B4E3A9-FE27-4A31-A213-92B461A5C846", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:*", "matchCriteriaId": "C82C2C69-D983-4317-968B-D1855DF8AE43", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "177A6E55-8D64-4CB8-B366-AE272E715932", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:*", "matchCriteriaId": "450DE127-DFED-4799-B8EA-0F95028E4BC3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "72D14DB5-6132-4442-8AB2-3ECE89B1D47C", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:*", "matchCriteriaId": "63F70060-0090-4BD7-8BF6-769989879ACD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4FDC53A8-3F99-481E-9B0A-F5AF296B5BD6", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA074FBE-1C3E-4441-8C51-52B555B85D9F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0424AECD-68D5-45F1-9F55-B72CB4DFE39C", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:*", "matchCriteriaId": "6304FA24-F194-4EE2-95F5-35D086F82C01", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "39663B8F-F349-49B3-A0CB-004F11D01E34", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "C8F515DF-36AC-49C1-B013-E87529775AB3", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "45008AE8-8386-4CBA-8C38-10C1A60150C2", "versionEndExcluding": "5.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:*", "matchCriteriaId": "A59C91EA-5D1B-4970-8C36-BD76BA420B12", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7F61995A-2018-4DAA-9529-BADC145B267F", "versionEndExcluding": "5.4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:*", "matchCriteriaId": "CAF3DA7A-6B80-4F20-835F-BF071197D1B0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC97A506-7E63-43A3-ACB0-DDAF3C5369C3", "versionEndExcluding": "4.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3F6299B-D7E3-4750-B016-7DCBC83C2287", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B8A4CF89-9DDA-4974-A886-CC0A912017F7", "versionEndExcluding": "4.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:*", "matchCriteriaId": "47F713E4-4B75-476E-BC21-92CA10198AE9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2CA7C987-779A-4B64-BFAC-73D54618AF04", "versionEndExcluding": "3.10.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E4C1BEF-D6B4-4260-9AC5-6F903EF6F4B1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F6EB11E9-4036-4A93-91DC-4D987B5FE2BA", "versionEndExcluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:*", "matchCriteriaId": "9FC408A8-903F-43A2-9D05-65AD4482FDBB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B9AF696-211F-4CAD-8A0E-402487E8DC50", "versionEndExcluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:*", "matchCriteriaId": "080E722F-FCD4-4967-86EE-151ADC5702E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D8763BB9-5DDA-4817-BDA6-63983CD4BC67", "versionEndExcluding": "6.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B74BBB98-0146-467E-B77B-E2FA1ABF2ED5", "versionEndExcluding": "4.03", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B2345F75-2CD1-4014-8F90-36A4FB4CC3BE", "versionEndExcluding": "4.03", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*", "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9831567D-6528-4ACA-99F9-1EC42CB4A90D", "versionEndExcluding": "14", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:*", "matchCriteriaId": "27BC04E4-8C6F-4A66-86C4-A8F793A10BDD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "E348069A-B809-4DF6-81E9-DC52C6E2C268", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ie\\/pb-link_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8ED91175-0AF3-424A-8C49-43587BB95EAB", "versionEndExcluding": "3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ie\\/pb-link:-:*:*:*:*:*:*:*", "matchCriteriaId": "8D43C16C-0719-4648-903F-6CC0FFF1835A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ie\\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7E909C1E-9329-4459-ACE3-AD906CD4A968", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ie\\/as-i_link_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "317863B6-0B71-4D03-83FE-FC59EBB5307C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C887573-8BE8-42CF-B35A-22F9311AC627", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:*", "matchCriteriaId": "3A5A3F7E-D039-430F-89B0-6AB4FD2428D4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80D166A8-1EEC-42F4-8EAB-1747247A7A05", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFA520B6-5177-43E4-87C0-C215F79FE9B4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C8E76BDE-C7E9-4D6B-B5D9-A456516CD016", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF513598-C3FA-4555-8133-A7276DDAFAC8", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5468C9FA-ADD9-4FD3-89FE-C3621F5CB0EC", "versionEndExcluding": "1.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:*", "matchCriteriaId": "55058209-8AE5-42AF-80D4-5A7A44307266", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "54B85DBA-24CA-4F95-89A5-D53D5AC69B0E", "versionEndExcluding": "2.2.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "ECC84D6F-F5E0-47CF-B11E-1C43F866D972", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0C9D0595-53CD-48C0-82E3-DB0B2EC17721", "versionEndExcluding": "1.0.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*", "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*", "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "55BE63B0-F44E-4FCD-B00C-77595BACC62E", "versionEndExcluding": "4.0.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:*", "matchCriteriaId": "49DA8715-D671-4D8F-A870-E61960A5AFA4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*", "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6BACBC9-7C60-4A41-B8C6-A5E46B568029", "versionEndExcluding": "4.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:*", "matchCriteriaId": "691CA334-4394-4ED6-B417-F67FC92228AE", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "32BD232D-A6BB-4D7B-BD00-1085D08D8A77", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:pn\\/pn_coupler:-:*:*:*:*:*:*:*", "matchCriteriaId": "CB2846BD-9DAB-44A2-87C9-39E3ACFE03FA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0FE40195-DE5A-4B9C-9455-FAF92FF090D0", "versionEndExcluding": "4.1.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:*", "matchCriteriaId": "9B339839-3D74-4E13-9EB6-24CA46F991A5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E9329BF4-D00A-4138-AA4C-93022002C0B9", "versionEndExcluding": "4.4.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:*", "matchCriteriaId": "7863DDDC-D5CE-44FE-89C4-0E8A702A91A8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "E62802E3-AFA3-4023-9671-95C220397956", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8C46E084-9732-4920-86C2-3A91830CBCE3", "versionEndExcluding": "4.2.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:*", "matchCriteriaId": "18C8B2FB-87C3-4DBB-9960-53FA545F26CB", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "42D3FAF4-9B78-4EEF-8D80-17E9B98228D2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "251EE4B2-F1C7-4ACF-B90D-4C0FE3D181E5", "versionEndExcluding": "2.3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:*", "matchCriteriaId": "598EEFC9-5240-4011-9017-A9557585AA19", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "4C096137-C1E3-4D19-87A9-BEB7A081DD1E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*", "matchCriteriaId": "7EFD4E99-5C66-443F-8B6F-FA01C895DE78", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2570E321-C28E-46FA-8693-1230B3B5FD1B", "versionEndExcluding": "6.0.6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F97B67B-4516-4AD9-B33C-7F480EE0DB4D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "582B49BD-4565-4D19-BBE6-A193BDFCE8B0", "versionEndExcluding": "4.2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D24953B-B3DF-4150-810C-64A94A55E829", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:*", "matchCriteriaId": "30DDEA9B-E1BF-4572-8E12-D13C54603E77", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E696D071-8601-40AA-BAF5-1452940E1D6E", "versionEndExcluding": "2.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "80BDBB38-20D2-48C3-8B58-62C2D8CC00B8", "versionEndExcluding": "2010", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:*", "matchCriteriaId": "EA59D713-F342-4CDA-BDC8-108352D385DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*", "matchCriteriaId": "CA5ADAB0-3985-4933-8CDD-D1546D8271CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4E36412A-1AAB-42D1-B0B4-7A7BBF3CB317", "versionEndExcluding": "1.1.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:*", "matchCriteriaId": "8582A3E8-C05E-4D0B-851D-8C3181ED61CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F84A65E6-4672-4B62-826E-6FAAE0B4A89D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "CBB058FA-3E70-4489-AAB1-0CB7EF16A2E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3D42184E-8998-4C40-9612-5C9DE193CC06", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "BA5CB62E-04B7-4DD3-AA06-EB4A4FA58E54", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "98FDB53A-8F5D-46AA-9366-F6480B12D744", "versionEndExcluding": "2.0.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "352651A0-F7CE-4689-8597-15F3764707A9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD2943F3-C46C-462E-9062-EE7B3E56CF72", "versionEndExcluding": "1.4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:*", "matchCriteriaId": "975EFBBB-33E1-4D04-9E06-93553D45539C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:*", "matchCriteriaId": "99A0D811-2751-420E-AD85-B6EC777C8CAE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5D7A7140-62A2-434F-AB79-1D47C918F1FE", "versionEndExcluding": "1.2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:*", "matchCriteriaId": "A2B61A79-C2B0-4C3D-A63C-B20FF78B2981", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*", "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*", "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "413AA7BE-CFE1-49DB-965F-1BD50D61F82F", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "82B4BE4B-3AE5-4039-B18D-A5DE3F1DDEF8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g120\\(c\\/p\\/d\\)_w._pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "0EE820D5-16B2-4565-9D83-AF018C08B5E5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4B3B0706-47CD-43FB-8E3A-7EEEF020AFBA", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "1D36CF8D-6DA4-49ED-9EF1-F96292F671EE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*", "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AC731378-CB83-4C15-BC6A-5A86DF9B62F1", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "51A78A0B-5D75-418A-98AC-6EBF50D89A8A", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7143613F-4627-4F62-8F1B-E64CCB20F3D1", "versionEndExcluding": "4.4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:*", "matchCriteriaId": "B428560B-2CAC-4A63-B677-724D95E12023", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "23B97849-01A7-4A8F-84DD-D25CF84D010B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "77A0BE57-1A9A-4564-9C53-CF47DEEF7991", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "376556D0-1AE2-4F80-B3CE-C0251E35C326", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*", "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "772FF972-2193-4639-B454-F92762E49C39", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "EE2B31F0-D45F-4B42-95D2-540C68C5F3DE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*", "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8EE54303-4FDA-42C7-B33B-BA884CD31339", "versionEndExcluding": "1.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "D870F289-F2BC-4105-A8F0-30E47CDE9FEF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "92A7198A-D6C5-4FBF-8860-5C8EA864718B", "versionEndExcluding": "4.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:*", "matchCriteriaId": "B5DA6BF7-ECB8-47F1-A791-E65CFF89A608", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:*", "matchCriteriaId": "879CF09E-4735-4A73-8E7B-215F2701F7E0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71CD07D8-ECED-47EF-B2BC-0585F9BB00C1", "versionEndExcluding": "4.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:*", "matchCriteriaId": "AEB948AA-7BD7-4A0F-B86E-38ECD722C086", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*", "matchCriteriaId": "7D97047C-9772-4AEB-B993-131EBBAE33BA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "28E3AB24-86B4-485D-8D3A-131E5C7F0108", "versionEndExcluding": "4.5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:*", "matchCriteriaId": "40AC387B-B799-4A34-8C9E-73D05B86801D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*", "matchCriteriaId": "765286DF-07EC-4C7A-AB8C-09559CD977EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE53BC8E-CDA7-476A-87CA-532F365C79A7", "versionEndExcluding": "15.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1150AED-CDBE-492C-95FF-3E02B3B447F1", "versionEndExcluding": "15.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AAE6A83-737B-47A9-86BB-652C7F6A8013", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:*", "matchCriteriaId": "42E8D21B-9CF4-4C2E-B33C-212BA29C7124", "versionEndExcluding": "15.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "55E03180-BE77-4A22-A6C1-FE90B9760570", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "02610368-4B97-4B3F-8592-64CF8F65D8AD", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:*", "matchCriteriaId": "61E7964A-E7A4-4CDE-B376-5BBEC5F00A73", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "BE5003DA-5488-47C1-B442-9137E849FDD5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:*", "matchCriteriaId": "DFE96226-A2DF-4A9E-8CBB-8D7CF328E404", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FCF9D803-FF47-4400-B2C4-1F4EE28E5AA8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:*", "matchCriteriaId": "2FFBFB96-1A35-4724-831B-68E3A9C32921", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "65EDC583-1BCE-4787-820F-39DBD280DADF", "versionEndExcluding": "2.7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:*", "matchCriteriaId": "568ED124-AEE8-4BDC-BB89-0F8F83BA7537", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D87643C3-6525-4CBD-BC0C-6B4DC30C8642", "versionEndExcluding": "1.1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*", "matchCriteriaId": "AE6AB995-D67B-43E5-B8FF-97C38D20CB10", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5C936A7A-1AF9-44E4-9CEC-0694A424616B", "versionEndExcluding": "1.1.8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*", "matchCriteriaId": "8DA1E7C4-6352-41A4-8A94-C24DDB456572", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D3F052D2-B537-4BF9-AF05-60107FDE0BEA", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "96C7E194-617D-4593-B544-10AEFF59CCA5", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1BF93390-E65B-434E-9891-271DF7D11F47", "versionEndExcluding": "4.7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:*", "matchCriteriaId": "55F6B737-7237-4D38-A0F0-9EFCE76DC9C4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FD67D30A-8681-41AE-B248-7E50BA1B9FC8", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "FCC0EE8B-1088-46B6-992A-B8E12A7B7DC2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "31393A1B-4DBC-476D-875E-463B4B887E1B", "versionEndExcluding": "4.8", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:*", "matchCriteriaId": "0206F9F2-27C7-4D2F-817B-13F8FA31E547", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E789146F-1FA4-42E4-B867-FD0F5A7316CA", "versionEndExcluding": "01.01.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "1E0B32CC-8268-4B38-BBC7-51154882EC82", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "05B55989-A3E9-4AA1-A619-C75FEAA0B5DA", "versionEndExcluding": "01.01.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "DA05435D-9A52-4D43-BE74-7D4C6C156AC6", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "52156691-1368-4C77-98A7-EA63089091C5", "versionEndExcluding": "01.01.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "5EE8B9B8-3C49-4296-9BC0-7E030878D479", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "EC052323-2E00-415D-847A-66F77AD5C3FD", "versionEndExcluding": "01.01.01", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:*", "matchCriteriaId": "8F884CAF-D152-4318-B49B-0D68936D2BD9", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F4E035CB-0F76-47C0-B2C7-93AFA8A7B38B", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6AEC7D6-7E5E-4CFF-99C8-7FBADA2479D5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-7_lte\\/us_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E4CEE93A-9641-424B-AF55-2C550CA568F2", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-7_lte\\/us:-:*:*:*:*:*:*:*", "matchCriteriaId": "00DDA679-D761-4986-A0A0-4C00178DF0B5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7D21A891-321B-42A3-8173-8E0743AEDD65", "versionEndExcluding": "2.1.82", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE0116F3-67FA-4129-B1FF-023774D179AF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "71BAF32C-35EA-4704-B75D-9EED01F8264B", "versionEndExcluding": "1.1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*", "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected." }, { "lang": "es", "value": "Los paquetes de difusi\u00f3n PROFINET DCP especialmente elaborados podr\u00edan causar una condici\u00f3n de denegaci\u00f3n de servicio de los productos afectados en un segmento Ethernet local (capa 2). Se requiere la interacci\u00f3n humana para recuperar los sistemas. Las interfaces PROFIBUS no est\u00e1n afectadas" } ], "id": "CVE-2017-2680", "lastModified": "2024-11-21T03:23:57.563", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "ADJACENT_NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 6.1, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 6.5, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "productcert@siemens.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "ADJACENT", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "productcert@siemens.com", "type": "Secondary" } ] }, "published": "2017-05-11T01:29:05.400", "references": [ { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98369" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securitytracker.com/id/1038463" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "source": "productcert@siemens.com", "tags": [ "Broken Link" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securityfocus.com/bid/98369" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "http://www.securitytracker.com/id/1038463" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-284673.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/html/ssa-546832.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-284673.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-023-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-284673.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2013-04-22 03:27
Modified
2024-11-21 01:48
Severity ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf | Broken Link, Vendor Advisory | |
ics-cert@hq.dhs.gov | https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf | Broken Link, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf | Vendor Advisory |
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | simatic_s7-1200_cpu_1211c_firmware | * | |
siemens | simatic_s7-1200_cpu_1211c | - | |
siemens | simatic_s7-1200_cpu_1212c_firmware | * | |
siemens | simatic_s7-1200_cpu_1212c | - | |
siemens | simatic_s7-1200_cpu_1212fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1212fc | - | |
siemens | simatic_s7-1200_cpu_1214_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1214_fc | - | |
siemens | simatic_s7-1200_cpu_1214c_firmware | * | |
siemens | simatic_s7-1200_cpu_1214c | - | |
siemens | simatic_s7-1200_cpu_1215_fc_firmware | * | |
siemens | simatic_s7-1200_cpu_1215_fc | - | |
siemens | simatic_s7-1200_cpu_1215c_firmware | * | |
siemens | simatic_s7-1200_cpu_1215c | - | |
siemens | simatic_s7-1200_cpu_1217c_firmware | * | |
siemens | simatic_s7-1200_cpu_1217c | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2A37383F-B3F7-423C-B956-87926E38B323", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "C3D4A8F2-6ACC-4809-8320-7A0305741069", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*", "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "7EBDF670-EA1F-45A4-8C2B-C52B5D2AF565", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*", "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0EC634AF-318C-4280-B0E3-1DE20C98962C", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D4A46E17-22DF-4FEB-B290-E209AF511B8E", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "233B1E82-769D-43AA-A051-CBAB0BD5F496", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*", "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "1CBD5520-7F19-44DE-AA9B-1D00475B987F", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*", "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E1B49EF-9276-47C7-ACE7-965B465BF202", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "919785E4-03B8-4BDF-9C3C-90538E24D13E", "versionEndExcluding": "4.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*", "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port)." }, { "lang": "es", "value": "Siemens SIMATIC S7-1200 PLCs v2.x y v3.x ermite a atacantes remotos causar una denegaci\u00f3n de servicios (transici\u00f3n de modo defecto e interrupci\u00f3n de control) a trav\u00e9s de paquetes TCP manipulados dirigidos al puerto 102 (conocido como puerto ISO-TSAP)." } ], "id": "CVE-2013-0700", "lastModified": "2024-11-21T01:48:01.540", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2013-04-22T03:27:13.047", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Broken Link", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2019-12-12 14:15
Modified
2024-11-21 04:25
Severity ?
Summary
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family < V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) < 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions <= V2.2.2 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions <= V2.3.0 and Function State (FS) <= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions <= V2.5.0 and Function State (FS) <= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-1200_firmware | * | |
siemens | simatic_s7-1200 | - | |
siemens | s7-200_smart_firmware | * | |
siemens | s7-200_smart | - | |
siemens | simatic_s7-200_smart_cpu_st20_firmware | * | |
siemens | simatic_s7-200_smart_cpu_st20 | - | |
siemens | simatic_s7-200_smart_cpu_st30_firmware | * | |
siemens | simatic_s7-200_smart_cpu_st30 | - | |
siemens | simatic_s7-200_smart_cpu_st40_firmware | * | |
siemens | simatic_s7-200_smart_cpu_st40 | - | |
siemens | simatic_s7-200_smart_cpu_st60_firmware | * | |
siemens | simatic_s7-200_smart_cpu_st60 | - | |
siemens | simatic_s7-200_smart_cpu_sr20_firmware | * | |
siemens | simatic_s7-200_smart_cpu_sr20 | - | |
siemens | simatic_s7-200_smart_cpu_sr30_firmware | * | |
siemens | simatic_s7-200_smart_cpu_sr30 | - | |
siemens | simatic_s7-200_smart_cpu_sr40_firmware | * | |
siemens | simatic_s7-200_smart_cpu_sr40 | - | |
siemens | simatic_s7-200_smart_cpu_sr60_firmware | * | |
siemens | simatic_s7-200_smart_cpu_sr60 | - | |
siemens | simatic_s7-200_smart_cpu_cr40_firmware | * | |
siemens | simatic_s7-200_smart_cpu_cr40 | - | |
siemens | simatic_s7-200_smart_cpu_cr60_firmware | * | |
siemens | simatic_s7-200_smart_cpu_cr60 | - | |
siemens | simatic_s7-200_smart_cpu_cr20s_firmware | * | |
siemens | simatic_s7-200_smart_cpu_cr20s | - | |
siemens | simatic_s7-200_smart_cpu_cr30s_firmware | * | |
siemens | simatic_s7-200_smart_cpu_cr30s | - | |
siemens | simatic_s7-200_smart_cpu_cr40s_firmware | * | |
siemens | simatic_s7-200_smart_cpu_cr40s | - | |
siemens | simatic_s7-200_smart_cpu_cr60s_firmware | * | |
siemens | simatic_s7-200_smart_cpu_cr60s | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A6AD4E09-BE4A-45D5-AA55-BA7365D12DD6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*", "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:s7-200_smart_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "44B4D7A7-E9B2-4F3D-A87E-C44426C923F4", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:s7-200_smart:-:*:*:*:*:*:*:*", "matchCriteriaId": "BB4495AE-B326-45C1-9CA8-A8BD97234D1C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A857E06F-0DAA-462E-B067-5FCAF626215D", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st20:-:*:*:*:*:*:*:*", "matchCriteriaId": "13D741B0-7F5A-4275-9735-D0634D06128C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "392AE5E1-6B9A-4F40-8B3B-1C9BBCAD13D6", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st30:-:*:*:*:*:*:*:*", "matchCriteriaId": "A65B5553-C61F-486D-9CB7-33346C3C2833", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A0EA8CFC-A1DC-42D5-8DB9-26FF3748F397", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st40:-:*:*:*:*:*:*:*", "matchCriteriaId": "041993EF-ED92-45C8-9D0F-CCB99CA6D789", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_st60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4905F166-016E-4ECE-82C4-1668708EB735", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_st60:-:*:*:*:*:*:*:*", "matchCriteriaId": "83012A83-6BED-4EAE-B144-F8F7A804F24B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr20_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "F96F95AB-651B-4BCB-BD78-65570A011242", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr20:-:*:*:*:*:*:*:*", "matchCriteriaId": "3606B1DC-DB6A-4E8D-972A-EB48F33918CF", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr30_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "47557189-8EEB-4ADE-AE74-C064B4A0DA4B", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr30:-:*:*:*:*:*:*:*", "matchCriteriaId": "D8D693F0-738C-4E31-93ED-4467A9D99E9C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "5326B002-BFD4-40AC-9234-485E0AE05887", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "E40D7FC9-E9EC-49FE-B60C-0DD9A0FA307F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_sr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD785A02-C3EA-415E-8764-D4514E83B0BA", "versionEndIncluding": "2.5.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_sr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "0211A90A-D654-45E3-A519-8928A31682CC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr40_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0CA9611A-9A9F-40D0-9A66-7ABA4F6B2985", "versionEndIncluding": "2.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr40:-:*:*:*:*:*:*:*", "matchCriteriaId": "415D9D18-5A3B-4D8C-90B3-F02DE378519C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr60_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "3188BE0B-A28D-487E-81EC-CA10BDDAE369", "versionEndIncluding": "2.2.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr60:-:*:*:*:*:*:*:*", "matchCriteriaId": "261039FA-7803-4072-857D-24F3613ABDB5", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr20s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B208404C-ACE6-49B8-955A-23B84864810C", "versionEndIncluding": "2.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr20s:-:*:*:*:*:*:*:*", "matchCriteriaId": "AFDD569B-53CD-497F-9339-94AA143916E4", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr30s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "9E352EB8-37E9-45C4-A7D2-2EDC4BA99DB4", "versionEndIncluding": "2.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr30s:-:*:*:*:*:*:*:*", "matchCriteriaId": "33D5ED5A-00BA-4F29-B5F2-257A90B100E7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr40s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "77DA47C6-4C54-4A88-8129-0DF0A161B79B", "versionEndIncluding": "2.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr40s:-:*:*:*:*:*:*:*", "matchCriteriaId": "718E9DD0-8F17-40E3-871B-7976359EC7C2", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-200_smart_cpu_cr60s_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D3FA2207-9C99-400B-BFC7-C7E33701E73A", "versionEndIncluding": "2.3.0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-200_smart_cpu_cr60s:-:*:*:*:*:*:*:*", "matchCriteriaId": "C760B61E-812F-4381-B9FA-6F887EB500E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family \u003c V4.x (incl. SIPLUS variants) (All versions), SIMATIC S7-1200 CPU family V4.x (incl. SIPLUS variants) (All versions with Function State (FS) \u003c 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (All versions \u003c= V2.2.2 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (All versions \u003c= V2.3.0 and Function State (FS) \u003c= 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (All versions \u003c= V2.5.0 and Function State (FS) \u003c= 8), SIMATIC S7-200 SMART CPU family (All versions). There is an access mode used during manufacturing of the affected devices that allows additional diagnostic functionality. The security vulnerability could be exploited by an attacker with physical access to the UART interface during boot process." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (Toas las versiones), SIMATIC S7-1200 CPU family \u0026lt; V4.x (incluidas las variantes SIPLUS) (Toas las versiones), SIMATIC S7-1200 CPU family V4.x (incluidas las variantes SIPLUS) (Toas las versiones with Function State (FS) anteriores a 11), SIMATIC S7-200 SMART CPU CR20s (6ES7 288-1CR20-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU CR30s (6ES7 288-1CR30-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU CR40 (6ES7 288-1CR40-0AA0) (Todas las versiones o igual a V2.2.2 y Function State (FS) anteriores o igual a 8), SIMATIC S7-200 SMART CPU CR40s (6ES7 288-1CR40-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU CR60 (6ES7 288-1CR60-0AA0) (Todas las versiones o igual a V2.2.2 y Function State (FS) anteriores o igual a 10), SIMATIC S7-200 SMART CPU CR60s (6ES7 288-1CR60-0AA1) (Todas las versiones o igual a V2.3.0 y Function State (FS) anteriores o igual a 3), SIMATIC S7-200 SMART CPU SR20 (6ES7 288-1SR20-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 11), SIMATIC S7-200 SMART CPU SR30 (6ES7 288-1SR30-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 10), SIMATIC S7-200 SMART CPU SR40 (6ES7 288-1SR40-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 10), SIMATIC S7-200 SMART CPU SR60 (6ES7 288-1SR60-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 12), SIMATIC S7-200 SMART CPU ST20 (6ES7 288-1ST20-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 9), SIMATIC S7-200 SMART CPU ST30 (6ES7 288-1ST30-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 9), SIMATIC S7-200 SMART CPU ST40 (6ES7 288-1ST40-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 8), SIMATIC S7-200 SMART CPU ST60 (6ES7 288-1ST60-0AA0) (Todas las versiones o igual a V2.5.0 y Function State (FS) anteriores o igual a 8), SIMATIC S7-200 SMART CPU family (Toas las versiones). Existe un modo de acceso utilizado durante la fabricaci\u00f3n de CPU S7-1200 que permite una funcionalidad de diagn\u00f3stico adicional. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso f\u00edsico a la interfaz UART durante el proceso de arranque" } ], "id": "CVE-2019-13945", "lastModified": "2024-11-21T04:25:44.930", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 6.8, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2019-12-12T14:15:15.133", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686531.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-749" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }