All the vulnerabilites related to siemens - simatic_s7-1200_cpu_1211c
Vulnerability from fkie_nvd
Published
2012-10-10 18:55
Modified
2024-11-21 01:40
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D6784CC-7FD8-4CD5-979F-0B9F62CE4AA3",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "90523ED2-CE36-4287-9D80-4A508DBD6E17",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D31C744-AD8E-4E72-9E3E-F9ED8EFE2D8A",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7EF332E-0725-44BB-8233-66B017D9DB20",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30F62D4A-8014-4B82-B219-37385F902436",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "021DC100-8C4D-452B-93E1-952AD9DA0954",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6058C37-D10F-498B-80A6-E6608BCAF793",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8339C357-7788-4D44-9075-CA3FFB837453",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D1B4F7D-D7A6-4E79-9EE1-211394B37AA7",
              "versionEndExcluding": "3.0.2",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de ejecuci\u00f3n de secuencias de comandos en sitios cruzados (XSS) en el servidor web SIMATIC S7-1200 PLCs v2.x hasta v3.0.1 permite a atacantes remotos inyectar secuencias de comandos web o HTML a trav\u00e9s de una URI espec\u00edficamente construida."
    }
  ],
  "id": "CVE-2012-3040",
  "lastModified": "2024-11-21T01:40:09.877",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2012-10-10T18:55:02.080",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://en.securitylab.ru/lab/PT-2012-50"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link"
      ],
      "url": "http://osvdb.org/86130"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://secunia.com/advisories/50816"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://en.securitylab.ru/lab/PT-2012-50"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "http://osvdb.org/86130"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://secunia.com/advisories/50816"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-04-12 09:15
Modified
2024-11-21 06:27
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.
Impacted products
Vendor Product Version
siemens simatic_step_7 *
siemens simatic_step_7 16
siemens simatic_step_7 16
siemens simatic_step_7 16
siemens simatic_step_7 16
siemens simatic_step_7 16
siemens simatic_step_7 17
siemens simatic_step_7 17
siemens simatic_s7-1200_cpu -
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu -
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BBCA2BFB-EEEB-4722-AC33-CBBFE92289BC",
              "versionEndExcluding": "16",
              "versionStartIncluding": "15",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*",
              "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*",
              "matchCriteriaId": "EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update2:*:*:*:*:*:*",
              "matchCriteriaId": "70AA41B2-8C18-4436-8C77-E6391EB0D8C9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update3:*:*:*:*:*:*",
              "matchCriteriaId": "0AF2FE58-C7FC-4FD6-8026-E23AEAAA29CB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update4:*:*:*:*:*:*",
              "matchCriteriaId": "C22708F4-5386-4C7A-B11A-677B8DDC36A0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:17:-:*:*:*:*:*:*",
              "matchCriteriaId": "211B89EA-80D2-441D-8CD6-693CCB1407F7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:17:update1:*:*:*:*:*:*",
              "matchCriteriaId": "7B23F0A5-8F54-407F-9DE1-30B10BAC6D85",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2B63726-10CE-46AB-ADBA-A511E770E162",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "01048F7F-9C5B-47C0-AE16-321FCA670F3D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) versi\u00f3n V15 (Todas las versiones), SIMATIC STEP 7 (TIA Portal) versi\u00f3n V16 (todas las versiones anteriores a versi\u00f3n V16 Update 5), SIMATIC STEP 7 (TIA Portal) versi\u00f3n V17 (todas las versiones anteriores a versi\u00f3n V17 Update 2). Un atacante podr\u00eda lograr una escalada de privilegios en el servidor web de determinados dispositivos debido a una vulnerabilidad de control de acceso inapropiada en el software del sistema de ingenier\u00eda. El atacante necesita tener acceso directo al servidor web afectado"
    }
  ],
  "id": "CVE-2021-42029",
  "lastModified": "2024-11-21T06:27:06.913",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.2,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-04-12T09:15:13.817",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-284"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 06:31
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware *
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1200_cpu_12_1211c_firmware *
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware *
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware *
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware *
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1214fc_firmware *
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware *
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware *
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1217c_firmware *
siemens simatic_s7-1200_cpu_12_1217c -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens simatic_s7-1500_cpu_1507s_firmware *
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f_firmware *
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s_firmware *
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f_firmware *
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c_firmware *
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c_firmware *
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_151511c-1_firmware *
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware *
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518_firmware *
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_cpu_15pro-2_firmware *
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_15prof-2_firmware *
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc -
siemens simatic_s7-1500_software_controller_firmware -
siemens simatic_s7-1500_software_controller -
siemens siplus_s7-300_cpu_314_firmware -
siemens siplus_s7-300_cpu_314 -
siemens siplus_s7-300_cpu_315-2_dp_firmware -
siemens siplus_s7-300_cpu_315-2_dp -
siemens siplus_s7-300_cpu_315-2_pn\/dp_firmware -
siemens siplus_s7-300_cpu_315-2_pn\/dp -
siemens siplus_s7-300_cpu_317-2_pn\/dp_firmware -
siemens siplus_s7-300_cpu_317-2_pn\/dp v6
siemens siplus_tim_1531_irc_firmware -
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware -
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C9A0C34-9116-4835-8372-C72273B9CE08",
              "versionEndExcluding": "5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3C6CC47-5B8D-4FF7-B836-AB2C5C5D4189",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30B06ABC-30A2-4E3D-9A3C-E3B70308B427",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE09A9F-1EA2-4390-9648-61B2318EA930",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B64D841-42F1-4942-8568-A4E3B64A9711",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDF6B5E8-3B42-4E79-82CD-54112C819C0E",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E57A3D6-F939-49CB-85ED-319A9A447FF6",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D13B9DEC-0DC1-4F4B-9CD8-B0C4849EE0A7",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3BB3B1-5501-4044-9B10-64C7865E0B69",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54F1417-426E-45B2-AACA-D3A4EEDA162D",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6A37E51-044D-4420-98C5-FCE1C9FA0B77",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC3792E-C935-4AE9-B07F-C32F10072861",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "510EB4BE-7425-48C9-A3AB-B7932CFBCBC4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1452445-A671-463B-B175-07122B0D0F0A",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B89FB6F-4635-49B4-AF9C-17882F1D79E4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8722D9A2-C1AE-4B19-8827-A0BAE35BCEBC",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D74CF17-23D8-4F5F-8387-F9F751DFC37C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "689A662A-4CB4-40B6-946F-9ED223C929C8",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75D64AC3-E8AD-4906-836E-C6C0C77FDD7F",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFB7D20A-C951-467B-902F-C5B61AEE8722",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92D26AE4-A61C-4DDE-AC0E-7ADA6C16168C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37574513-3CE7-4A82-A495-272FDD01FADE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3A272D-45A1-4195-9B11-65D6BAACC425",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C48F5FEA-357C-4630-940F-06C7D175B8F2",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C73EC1A-3099-4099-AC21-2B5BA82B428E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85AECB2F-8AEC-4503-B45B-E32F6B081481",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A94DA11-E1EC-4792-8D08-D96C24EA60A7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1858266-384F-415E-AC75-9082729E80C0",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAD92A57-8592-4594-BAFE-BE50B9421EEA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28DAE724-8A2A-42EB-A407-FE3CC5E11303",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2923D75B-ACF8-47FF-859D-5F780CBF8A2B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79A2DD7B-FE32-4873-9689-64B34BD7A871",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17C0E003-6B46-4D32-9EF2-7EEC1E625534",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41E677CA-74B5-4281-816F-13B754EAEC85",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E60CDAF9-C304-4895-B60B-7BCE87B6AF62",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B209AD7-8F7D-4D8D-9C0E-ADBBBDF0D2D1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58B467A4-41F0-4CA3-9BE4-B5DBBE0B75A4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62A4DD30-1982-4126-8D18-9E9A18B88E52",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03CB600B-A8BD-4C13-940F-A7E22C732129",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F08F8454-11F2-4903-8845-17BA53092E99",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E8AD64D-AE4E-4E56-B64D-80C3FEB50839",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA9AF054-5D96-4C5D-87BA-73949C4D3BA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F18A96A0-C9C2-4F86-911A-FBEAB37D774E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A23DFA83-45DC-4FEE-9291-4B35487B2BEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "966ACB66-7F82-4784-9969-63F4B82385F7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "726B3940-F85B-4760-8C07-56C9B7EE6221",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C972215A-F45D-4730-80C9-72874221408C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AD40846-918D-4970-8FDC-4368CCD730D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5837F598-317F-48CE-AC05-2832F68DB71B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0B146AC-0BF0-42EF-9818-FEE8BC98197B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "60DEC18D-5A11-4CC4-9169-31130418A5E4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F89A4C42-7FC8-48B0-AC56-D5E5DC3771EF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1B00477-3871-4B60-94E2-93FDCAF2C921",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5983C923-9D2F-4888-8C7F-1F7C40F45B69",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE7EAEC5-1B73-4A47-81F8-18ADDF5E66A8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BA8F18C-446C-4795-B9EB-2213336F8DEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1B256C1-7476-437C-935F-B44E27589F37",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C9E1DB6-0613-479E-8215-7C8ED8736321",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06F09B1-5A87-4232-B604-A51445FF707E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F909702-CAD9-40F9-8CD0-1EAFB49EB108",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5A41226-5658-4871-9DA9-70802E0A939E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEF75D1-E68E-42F3-9A15-D31116854212",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "382C22D4-DB54-4AC9-9F31-0386264BE4DF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83F5D1D3-2452-47F8-85D6-24EF159342DA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DBE49-F5ED-46DC-B7B7-61C4624BD8D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A6E4A98-5656-4CCD-B41E-0413D1E0584D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2281F79-9098-4FEC-8303-3C426870BEE8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCD72B5F-10B0-4CF6-8498-8431384CDBA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA937CE7-4E65-45BA-8750-3498D3A4F4F4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "815E4D53-C0F4-4DE8-A9F9-998838D4E300",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66F5A4A6-D7F8-492C-A254-84F3EF3BDF1D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8C580F7-A436-4CDA-B273-A60EF5E7552C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92B4D260-9A8E-443B-8792-4FFD22137639",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF0FE9D-6A93-4F82-8CD7-0CB61079AC1C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2357ABBA-34A0-4D0D-8204-B47B29360574",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C1538F5-0FFE-4186-BB66-937CD0D1B5B3",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB41012B-98EF-4BF3-B103-F70F536E625E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18798AFB-14A8-412A-9886-71F403A888FC",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1475BB2A-72B0-44E1-9B0C-3D9DC61E8528",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "931D71AF-75B0-41BA-A0D8-C84EC4D5A350",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AA99065-A472-46E7-B65D-13424D3296BD",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E91666-3BEA-4F79-ACF0-F8FA58541E06",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490F5F0-3B3C-4501-AA0B-BED085534CB8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5513224-CDB4-4E7F-A296-131555F0CC93",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7803F3CE-F6DA-441C-A5AB-DE1FF0C56DF1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "755E97AB-6AD7-454D-9E35-3472B82A23F1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "214EDE7C-033D-4FB1-8FE1-17E99D7A9033",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA976CCF-1C34-461E-AEB3-DAEF0D251BDE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C665C2D3-80A3-4969-BABB-004B97A21B7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD7DA13A-BF1F-4501-A259-190BA4996B23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "83900616-A91E-45B2-AE17-1D68E1B8BA57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88F00AE1-D55A-4C7C-A421-2B89BDFE4C9D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A856E00C-965C-478F-A6D8-79EDCF342DDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D038857-CED3-4312-9B86-36DC10A0398F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_315-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61D2CA3D-D97B-4AC7-AAA7-F2444667B74B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_315-2_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FC6FF34-3155-4CF8-88D5-4EAE00B32163",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88CEE87A-2A0D-45E9-967E-F88EC87EE687",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_317-2_pn\\/dp:v6:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5CDFEA-E5F2-419F-A1B3-D98C44D38D84",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "820BF9F7-4283-4924-82F5-943172C32E2F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4068A0FB-8DAC-40AA-A016-5DE552EF20AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podr\u00eda permitir a un atacante provocar una denegaci\u00f3n de servicio en el dispositivo."
    }
  ],
  "id": "CVE-2021-44693",
  "lastModified": "2024-11-21T06:31:23.340",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-12-13T16:15:14.750",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1284"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1284"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2021-03-25 15:15
Modified
2024-11-21 06:21
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
openssl-security@openssl.orghttp://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
openssl-security@openssl.orghttps://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
openssl-security@openssl.orghttps://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
openssl-security@openssl.orghttps://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
openssl-security@openssl.orghttps://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
openssl-security@openssl.orghttps://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
openssl-security@openssl.orghttps://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
openssl-security@openssl.orghttps://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
openssl-security@openssl.orghttps://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
openssl-security@openssl.orghttps://security.gentoo.org/glsa/202103-03Third Party Advisory
openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
openssl-security@openssl.orghttps://security.netapp.com/advisory/ntap-20240621-0006/
openssl-security@openssl.orghttps://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
openssl-security@openssl.orghttps://www.debian.org/security/2021/dsa-4875Third Party Advisory
openssl-security@openssl.orghttps://www.openssl.org/news/secadv/20210325.txtVendor Advisory
openssl-security@openssl.orghttps://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
openssl-security@openssl.orghttps://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-05Third Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-06Third Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-09Third Party Advisory
openssl-security@openssl.orghttps://www.tenable.com/security/tns-2021-10Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/1Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/27/2Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/3Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.openwall.com/lists/oss-security/2021/03/28/4Mailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdfThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdfPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
af854a3a-2127-422b-91ae-364da2661108https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://kc.mcafee.com/corporate/index?page=content&id=SB10356Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlMailing List, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/
af854a3a-2127-422b-91ae-364da2661108https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.ascThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.gentoo.org/glsa/202103-03Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210326-0006/Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20210513-0002/Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20240621-0006/
af854a3a-2127-422b-91ae-364da2661108https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.debian.org/security/2021/dsa-4875Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.openssl.org/news/secadv/20210325.txtVendor Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com//security-alerts/cpujul2021.htmlPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuApr2021.htmlPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuapr2022.htmlPatch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpujul2022.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.oracle.com/security-alerts/cpuoct2021.htmlThird Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-05Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-06Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-09Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108https://www.tenable.com/security/tns-2021-10Third Party Advisory
Impacted products
Vendor Product Version
openssl openssl *
debian debian_linux 9.0
debian debian_linux 10.0
freebsd freebsd 12.2
freebsd freebsd 12.2
freebsd freebsd 12.2
netapp active_iq_unified_manager -
netapp cloud_volumes_ontap_mediator -
netapp e-series_performance_analyzer -
netapp oncommand_insight -
netapp oncommand_workflow_automation -
netapp ontap_select_deploy_administration_utility -
netapp santricity_smi-s_provider -
netapp snapcenter -
netapp storagegrid -
tenable log_correlation_engine *
tenable nessus *
tenable nessus_network_monitor 5.11.0
tenable nessus_network_monitor 5.11.1
tenable nessus_network_monitor 5.12.0
tenable nessus_network_monitor 5.12.1
tenable nessus_network_monitor 5.13.0
tenable tenable.sc *
fedoraproject fedora 34
mcafee web_gateway 8.2.19
mcafee web_gateway 9.2.10
mcafee web_gateway 10.1.1
mcafee web_gateway_cloud_service 8.2.19
mcafee web_gateway_cloud_service 9.2.10
mcafee web_gateway_cloud_service 10.1.1
checkpoint quantum_security_management_firmware r80.40
checkpoint quantum_security_management_firmware r81
checkpoint quantum_security_management -
checkpoint multi-domain_management_firmware r80.40
checkpoint multi-domain_management_firmware r81
checkpoint multi-domain_management -
checkpoint quantum_security_gateway_firmware r80.40
checkpoint quantum_security_gateway_firmware r81
checkpoint quantum_security_gateway -
oracle communications_communications_policy_management 12.6.0.0.0
oracle enterprise_manager_for_storage_management 13.4.0.0
oracle essbase 21.2
oracle graalvm 19.3.5
oracle graalvm 20.3.1.2
oracle graalvm 21.0.0.2
oracle jd_edwards_enterpriseone_tools *
oracle jd_edwards_world_security a9.4
oracle mysql_connectors *
oracle mysql_server *
oracle mysql_server *
oracle mysql_workbench *
oracle peoplesoft_enterprise_peopletools 8.57
oracle peoplesoft_enterprise_peopletools 8.58
oracle peoplesoft_enterprise_peopletools 8.59
oracle primavera_unifier *
oracle primavera_unifier 19.12
oracle primavera_unifier 20.12
oracle primavera_unifier 21.12
oracle secure_backup *
oracle secure_global_desktop 5.6
oracle zfs_storage_appliance_kit 8.8
sonicwall sma100_firmware *
sonicwall sma100 -
sonicwall capture_client 3.5
sonicwall sonicos 7.0.1.0
siemens ruggedcom_rcm1224_firmware *
siemens ruggedcom_rcm1224 -
siemens scalance_lpe9403_firmware *
siemens scalance_lpe9403 -
siemens scalance_m-800_firmware *
siemens scalance_m-800 -
siemens scalance_s602_firmware *
siemens scalance_s602 -
siemens scalance_s612_firmware *
siemens scalance_s612 -
siemens scalance_s615_firmware *
siemens scalance_s615 -
siemens scalance_s623_firmware *
siemens scalance_s623 -
siemens scalance_s627-2m_firmware *
siemens scalance_s627-2m -
siemens scalance_sc-600_firmware *
siemens scalance_sc-600 -
siemens scalance_w700_firmware *
siemens scalance_w700 -
siemens scalance_w1700_firmware *
siemens scalance_w1700 -
siemens scalance_xb-200_firmware *
siemens scalance_xb-200 -
siemens scalance_xc-200_firmware *
siemens scalance_xc-200 -
siemens scalance_xf-200ba_firmware *
siemens scalance_xf-200ba -
siemens scalance_xm-400_firmware *
siemens scalance_xm-400 -
siemens scalance_xp-200_firmware *
siemens scalance_xp-200 -
siemens scalance_xr-300wg_firmware *
siemens scalance_xr-300wg -
siemens scalance_xr524-8c_firmware *
siemens scalance_xr524-8c -
siemens scalance_xr526-8c_firmware *
siemens scalance_xr526-8c -
siemens scalance_xr528-6m_firmware *
siemens scalance_xr528-6m -
siemens scalance_xr552-12_firmware *
siemens scalance_xr552-12 -
siemens simatic_cloud_connect_7_firmware *
siemens simatic_cloud_connect_7_firmware -
siemens simatic_cloud_connect_7 -
siemens simatic_cp_1242-7_gprs_v2_firmware *
siemens simatic_cp_1242-7_gprs_v2_firmware -
siemens simatic_cp_1242-7_gprs_v2 -
siemens simatic_hmi_basic_panels_2nd_generation_firmware *
siemens simatic_hmi_basic_panels_2nd_generation -
siemens simatic_hmi_comfort_outdoor_panels_firmware *
siemens simatic_hmi_comfort_outdoor_panels -
siemens simatic_hmi_ktp_mobile_panels_firmware *
siemens simatic_hmi_ktp_mobile_panels -
siemens simatic_mv500_firmware *
siemens simatic_mv500 -
siemens simatic_net_cp_1243-1_firmware *
siemens simatic_net_cp_1243-1 -
siemens simatic_net_cp1243-7_lte_eu_firmware *
siemens simatic_net_cp1243-7_lte_eu -
siemens simatic_net_cp1243-7_lte_us_firmware *
siemens simatic_net_cp1243-7_lte_us -
siemens simatic_net_cp_1243-8_irc_firmware *
siemens simatic_net_cp_1243-8_irc -
siemens simatic_net_cp_1542sp-1_irc_firmware *
siemens simatic_net_cp_1542sp-1_irc -
siemens simatic_net_cp_1543-1_firmware *
siemens simatic_net_cp_1543-1 -
siemens simatic_net_cp_1543sp-1_firmware *
siemens simatic_net_cp_1543sp-1 -
siemens simatic_net_cp_1545-1_firmware *
siemens simatic_net_cp_1545-1 -
siemens simatic_pcs_7_telecontrol_firmware *
siemens simatic_pcs_7_telecontrol -
siemens simatic_pcs_neo_firmware *
siemens simatic_pcs_neo -
siemens simatic_pdm_firmware *
siemens simatic_pdm -
siemens simatic_process_historian_opc_ua_server_firmware *
siemens simatic_process_historian_opc_ua_server -
siemens simatic_rf166c_firmware *
siemens simatic_rf166c -
siemens simatic_rf185c_firmware *
siemens simatic_rf185c -
siemens simatic_rf186c_firmware *
siemens simatic_rf186c -
siemens simatic_rf186ci_firmware *
siemens simatic_rf186ci -
siemens simatic_rf188c_firmware *
siemens simatic_rf188c -
siemens simatic_rf188ci_firmware *
siemens simatic_rf188ci -
siemens simatic_rf360r_firmware *
siemens simatic_rf360r -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware *
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens sinamics_connect_300_firmware *
siemens sinamics_connect_300 -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_logon *
siemens simatic_logon 1.5
siemens simatic_wincc_runtime_advanced *
siemens simatic_wincc_telecontrol -
siemens sinec_nms 1.0
siemens sinec_nms 1.0
siemens sinec_pni -
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinema_server 14.0
siemens sinumerik_opc_ua_server *
siemens tia_administrator *
siemens sinec_infrastructure_network_services *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *
nodejs node.js *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B213E696-A6D9-45E7-B4E4-E4CFE54ECEB8",
              "versionEndExcluding": "1.1.1k",
              "versionStartIncluding": "1.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEECE5FC-CACF-4496-A3E7-164736409252",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:debian:debian_linux:10.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "07B237A9-69A3-4A9C-9DA0-4E06BD37AE73",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "73D9C08B-8F5B-40C4-A5BD-B00D2E4C012D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p1:*:*:*:*:*:*",
              "matchCriteriaId": "62A178A3-6A52-4981-9A27-FB07AD8AF778",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:freebsd:freebsd:12.2:p2:*:*:*:*:*:*",
              "matchCriteriaId": "54A487B1-E5CE-4C76-87E8-518D24C5D86D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:netapp:active_iq_unified_manager:-:*:*:*:*:vmware_vsphere:*:*",
              "matchCriteriaId": "3A756737-1CC4-42C2-A4DF-E1C893B4E2D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:cloud_volumes_ontap_mediator:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "280AA828-6FA9-4260-8EC1-019423B966E1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:e-series_performance_analyzer:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "24B8DB06-590A-4008-B0AB-FCD1401C77C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:oncommand_insight:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1BE6C1F-2565-4E97-92AA-16563E5660A5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:oncommand_workflow_automation:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5735E553-9731-4AAC-BCFF-989377F817B3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:ontap_select_deploy_administration_utility:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7CF3019-975D-40BB-A8A4-894E62BD3797",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:santricity_smi-s_provider:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "361B791A-D336-4431-8F68-8135BEFFAEA2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:snapcenter:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BDFB1169-41A0-4A86-8E4F-FDA9730B1E94",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:netapp:storagegrid:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8ADFF451-740F-4DBA-BD23-3881945D3E40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:tenable:log_correlation_engine:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4ACF85D6-6B45-43DA-9C01-F0208186F014",
              "versionEndExcluding": "6.0.9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC12300-9051-4C70-9941-9FE5E64B4B30",
              "versionEndIncluding": "8.13.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "657682A0-54D5-4DC6-A98E-8BAF685926C4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.11.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FC5C76C-3474-4B26-8CF0-2DFAFA3D5458",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8661D361-71B5-4C41-A818-C89EC551D900",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.12.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "253603DC-2D92-442A-B3A8-A63E14D8A070",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:nessus_network_monitor:5.13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E112CFF-31F9-4D87-9A1B-AE0FCF69615E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:tenable:tenable.sc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC1721B5-9FCD-47C3-8338-E02932CF2C05",
              "versionEndIncluding": "5.17.0",
              "versionStartIncluding": "5.13.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:fedoraproject:fedora:34:*:*:*:*:*:*:*",
              "matchCriteriaId": "A930E247-0B43-43CB-98FF-6CE7B8189835",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway:8.2.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEA7F1FD-9FAB-4654-98B0-4588EEC8B69A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway:9.2.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "868B2C4B-CE6B-41DA-A373-7D4FA51EFE9F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway:10.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "550F47A2-3393-481E-BC40-CE606BFA8776",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:8.2.19:*:*:*:*:*:*:*",
              "matchCriteriaId": "43392D27-6C07-41C7-A17F-10C433338CE9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:9.2.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "8FBF6C4C-195F-49A7-861D-52677D9BE58D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mcafee:web_gateway_cloud_service:10.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "90732D53-E802-4E1B-B6C8-B1FDCE7905A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r80.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "A98B128A-C58E-48EC-B691-AF73126A0822",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_management_firmware:r81:*:*:*:*:*:*:*",
              "matchCriteriaId": "345B990F-C1C4-440B-804E-0A2882FE7C01",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:checkpoint:quantum_security_management:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "08601413-25E2-4977-B67A-C11A9D788EA8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r80.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "EFC067CC-EB90-43F5-9674-089D5C611573",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:checkpoint:multi-domain_management_firmware:r81:*:*:*:*:*:*:*",
              "matchCriteriaId": "80B223A7-1039-445D-ABE1-5E481004D956",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:checkpoint:multi-domain_management:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1584E1B4-412C-40E2-BF07-4E464692F2AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r80.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0002A29-8B42-445D-9EC4-58BC93194241",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:checkpoint:quantum_security_gateway_firmware:r81:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B0EDB21-9305-4601-AB96-A77BD00F311D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:checkpoint:quantum_security_gateway:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9016DDF6-285C-4E64-88D0-29ECCEF048F8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:oracle:communications_communications_policy_management:12.6.0.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "570DB369-A31B-4108-A7FD-09F674129603",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:enterprise_manager_for_storage_management:13.4.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "61516569-C48F-4362-B334-8CA10EDB0EC2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:essbase:21.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "394A16F2-CCD4-44E5-BF6B-E0C782A9FA38",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:graalvm:19.3.5:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "058C7C4B-D692-49DE-924A-C2725A8162D3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:graalvm:20.3.1.2:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "0F0434A5-F2A1-4973-917C-A95F2ABE97D1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:graalvm:21.0.0.2:*:*:*:enterprise:*:*:*",
              "matchCriteriaId": "96DD93E0-274E-4C36-99F3-EEF085E57655",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:jd_edwards_enterpriseone_tools:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86305E47-33E9-411C-B932-08C395C09982",
              "versionEndExcluding": "9.2.6.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B1CAD50-749F-4ADB-A046-BF3585677A58",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_connectors:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A8782A14-89B0-45EE-A5CB-FF715F5BA379",
              "versionEndIncluding": "8.0.23",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C40ECC8-933B-47A4-8082-FCF0EF9C973E",
              "versionEndIncluding": "5.7.33",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "32714AD7-BCD1-4624-9923-5E6D927CF3CB",
              "versionEndIncluding": "8.0.23",
              "versionStartIncluding": "8.0.15",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:mysql_workbench:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB1A94E1-A6C6-488D-A74C-6C0B24637272",
              "versionEndIncluding": "8.0.23",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E1E416B-920B-49A0-9523-382898C2979D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.59:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8AF00C6-B97F-414D-A8DF-057E6BFD8597",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "08FA59A8-6A62-4B33-8952-D6E658F8DAC9",
              "versionEndIncluding": "17.12",
              "versionStartIncluding": "17.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:19.12:*:*:*:*:*:*:*",
              "matchCriteriaId": "10864586-270E-4ACF-BDCC-ECFCD299305F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:20.12:*:*:*:*:*:*:*",
              "matchCriteriaId": "38340E3C-C452-4370-86D4-355B6B4E0A06",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:primavera_unifier:21.12:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9C55C69-E22E-4B80-9371-5CD821D79FE2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:secure_backup:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C01E8B82-71C7-4A4A-A70A-7B147524AB4A",
              "versionEndExcluding": "18.1.0.1.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:secure_global_desktop:5.6:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DA11710-9EA8-49B4-8FD1-3AEE442F6ADC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:oracle:zfs_storage_appliance_kit:8.8:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3E503FB-6279-4D4A-91D8-E237ECF9D2B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sma100_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E8B6D50-D482-43E9-A20D-FA77FD59AE2D",
              "versionEndExcluding": "10.2.1.0-17sv",
              "versionStartIncluding": "10.2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sma100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4A2B7B-40F5-4AE0-ACC7-E94B82435DBA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:sonicwall:capture_client:3.5:*:*:*:*:*:*:*",
              "matchCriteriaId": "349EB4AE-65E3-42DC-8F9C-3A1A155324D7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:sonicwall:sonicos:7.0.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BD8688A-2D55-4A7E-A143-1BD0FCF957B0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ruggedcom_rcm1224_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5081E52B-E7C0-46BD-B1D0-2C70ABCC8831",
              "versionStartIncluding": "6.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ruggedcom_rcm1224:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3747CDD7-E833-4B68-A362-77D6A2E9D888",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_lpe9403_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "058D21EA-E94C-4DDC-AD92-967DAC934457",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_lpe9403:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "52A77C9D-E59C-4397-B834-797D7B334A6B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "424CD8EA-D8CB-40C7-8E0F-AC4B05C59C99",
              "versionStartIncluding": "6.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFB9921A-5204-40A3-88AB-B7755F5C6875",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s602_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "858B6A84-5D0E-4E23-AE32-A45B51BAC8CF",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s602:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4D89D82-C2CE-44DC-A05B-B956F20BF4E3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s612_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D173626B-9C50-489F-8BA4-1C45E5F96526",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s612:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA7B48D2-0D17-420D-AAE1-35E5C0BE2924",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E967F5FC-6F3E-4982-8813-CA1DAF3BE165",
              "versionStartIncluding": "6.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E917CBBB-EF41-4113-B0CA-EB91889235E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s623_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "81F315D8-0B26-4442-B330-85124017A482",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s623:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F80D9A79-7984-462B-B4B9-6A4429422038",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_s627-2m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F20F735-7A70-4A24-9621-786F99C8F87D",
              "versionStartIncluding": "4.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_s627-2m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B51B40F8-71D2-4D2D-8EC2-CE154A6D7533",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_sc-600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "973B8030-B630-4D67-B897-25A359A96185",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_sc-600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "725C671B-D7A0-48CF-8A31-5F9C4173F1DD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "86EA8E3F-81BD-47BC-9834-A9B69CA7E70C",
              "versionStartIncluding": "6.5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3033B1E-57A6-4AE3-A861-7047CF8EAD79",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_w1700_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE116AD9-B55F-41C8-8B55-329809DB63E1",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_w1700:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5D9A73DD-4A21-4096-B4B6-A0A825E71006",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xb-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "144CDF5E-7E07-428B-B4DF-C94992B3A44A",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xb-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CB3CC2D-CBF0-4F53-A412-01BBC39E34C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xc-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "339FFBDF-6957-481F-84CE-878B5CAAD9C8",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xc-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7719E194-EE3D-4CE8-8C85-CF0D82A553AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xf-200ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6FBB13D3-4E04-4D01-B880-C16C4FFA240B",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xf-200ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "58377C58-F660-4C17-A3CB-BFC2F28848CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xm-400_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E40058B3-3726-4F6A-AB41-7679487639F2",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xm-400:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "798E900F-5EF9-4B39-B8C2-79FAE659E7F5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xp-200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E642D10-E701-44DF-863B-D0DAA5530F50",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xp-200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F962FC7-0616-467F-8CCA-ADEA224B5F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr-300wg_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A53C2B5-A3FD-44CC-A78B-D2124EF37DB4",
              "versionEndExcluding": "4.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300wg:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "434BC9BE-C5DB-4DAF-8E07-DFE4EEA0D7FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr524-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54FBE4D4-F31E-4B61-9216-44C8EC2988AB",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr524-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0E6B7D8-3F9E-43D6-AEFE-DEE3993679C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr526-8c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "20511D61-FC1D-453E-BDF6-D3FB9951192A",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr526-8c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "67661569-6233-4C74-9C72-88BD14B257FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr528-6m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "640AC619-B516-46FC-821B-09C4542A3FD6",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr528-6m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3E048C4A-A414-4C87-A865-4D4218AE32EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:scalance_xr552-12_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FB979DB-731B-4693-A9F8-B11ED953717C",
              "versionEndExcluding": "6.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr552-12:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "09743616-31C9-4E47-8A4A-B15D76204BE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "886D2FE6-B054-4E3B-BACB-F08C0A119A80",
              "versionStartIncluding": "1.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cloud_connect_7_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B185B70-CAC9-47AC-8639-7A4707C21540",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cloud_connect_7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FA78457-260C-467B-9785-04B3C8EDF3B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABEA3BEE-E7AF-4C9A-ADE4-CE7FC1DB7639",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_v2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "049460B8-6186-44F9-B41F-284A2EC0B3B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1242-7_gprs_v2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "205482DA-548C-4757-91F0-1599438873BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_basic_panels_2nd_generation_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45208694-635A-42AC-B668-8B67C60568B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_basic_panels_2nd_generation:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D8F8BCE-35CE-492A-8BFE-2C36EA51CE5C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4C147D9-4649-4289-B18B-55BD6E33521A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F4830E0D-0128-4E5B-AB81-2B238471AE4B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv500_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE4FA1E6-4C5A-4CDC-AD40-E384C0BCA90D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv500:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "93A5B50E-0316-4189-8F41-54732CFCF63F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D254DA1D-C53E-426B-9C69-580CC47CF0AA",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65278BA0-3C81-4D81-9801-D7BE3A1D7680",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_eu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C06A02ED-0BA3-4A2C-AF0C-689B8AEB34B8",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_eu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "209C7B1E-10F6-4215-AF69-CC36192E0FCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp1243-7_lte_us_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF8C00EE-1154-440C-A223-A2CE99CE3126",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp1243-7_lte_us:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "171A9543-E677-422F-8AEA-1BC2D0E53593",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1243-8_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB201DD3-8890-453E-A11E-1E13B3DAB3F9",
              "versionStartIncluding": "3.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1243-8_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "350FD323-C876-4C7A-A2E7-4B0660C87F6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E498B1-87FF-454B-8DF0-61D0D3208491",
              "versionStartIncluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1542sp-1_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1EE2F10-A7A6-486F-AE5C-53AE25BAF200",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "90FB801F-11B5-438C-98A1-E928BFEA2ADB",
              "versionEndExcluding": "3.0",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F56C2BDC-928E-491A-8E7C-F976B3787C7A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1543sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E4BA1E6-64F7-4B96-8302-134057DAB1BE",
              "versionStartIncluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1543sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "783B50B8-2FB7-4982-88AA-B4F2AD094796",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_net_cp_1545-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DCA9544-DD17-4F56-B34C-91A3F37154AF",
              "versionStartIncluding": "1.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_net_cp_1545-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1256EB4B-DD8A-4F99-AE69-F74E8F789C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_7_telecontrol_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C25165E-EDE9-42F1-A3B9-0E47630D49CC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs_7_telecontrol:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BF281FB-26E0-43E4-A2B6-4015661368AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_neo_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EEACFC9-41B7-4EE0-9427-692363880326",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs_neo:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF3CA343-CA2A-4593-930C-158612CE7A55",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pdm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E9AE23E-7DAE-4191-BA4E-A7CD655C4BC8",
              "versionStartIncluding": "9.1.0.7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pdm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E092B735-42D5-48D5-947B-288C0FA2E180",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_process_historian_opc_ua_server_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D874D636-392A-4750-B976-F411DBCEBA8D",
              "versionStartIncluding": "2019",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_process_historian_opc_ua_server:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14EC9343-7778-40B0-A74D-5C156FF2A229",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "968FBB4E-5B0B-43D4-B3AD-418028093990",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "391AD485-A49D-43D0-AAE5-1F58B38D4E22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5212F097-B65A-4D73-BB6F-49687F8AD980",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "82494B5E-80EE-47ED-B87E-CF8C8907B6FE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D806113B-57EB-4AA0-9D5E-12E30337A93B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B0933EB-82BE-42BB-978B-C9EC2FE1C795",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "53FA50A7-2DF6-454E-8A8E-838C392AB417",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F3D41E9-58B3-4251-8710-A8C4A24ABBD3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E21F9909-8D80-40BE-81E0-6ED7FE140A3A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC628CB7-0816-4267-9C5D-954BD0233D2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0927991-E820-4FC3-9EFE-96E4C9BFCCCD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "88E64167-16AA-48D7-BCDC-B15D37FA666D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "63F05227-208B-42C8-8D56-A5D106CAD32F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47F1294A-1C26-4D43-9C53-D833F2510536",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4AF60081-D534-44F5-972F-23257F16F372",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEF1726E-B56F-4D39-AFF4-E79A3CA00DE6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4948734A-0AAD-4D28-B7FF-FFBBB9AA39C6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CC4A9F7-9858-4F95-8097-F8D09DA61314",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6EE37798-B068-40E5-BC03-1D8D303E5926",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8E0C491C-5C4A-4F1C-ABD4-9502A54AAA78",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7657063-1296-4734-B108-A2FF7A01B07F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C477CCD-06C7-4907-8B0C-4FCE7F6DADAD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_connect_300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3360ACCE-E735-4E34-B278-0D4460E74CBF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_connect_300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B854F5B-78C7-41FE-9364-5E71B36342A3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2B20D95-C4B3-4D13-A3D8-F22AC42DC059",
              "versionEndExcluding": "2.2",
              "versionStartIncluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_logon:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6F24E40-F3F0-48F3-B3DC-5F98B0564F7A",
              "versionStartIncluding": "1.6.0.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_logon:1.5:sp3_update_1:*:*:*:*:*:*",
              "matchCriteriaId": "423359E5-9C36-4C6B-AB24-B030E6C61D53",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79EE15DC-74D3-4551-AAD0-EA0CB600DA76",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_telecontrol:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3169FD3-CBA2-417C-95EF-4F8AE9FAB5AD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "4ED13FC8-63C0-42C6-A51C-C480C45327C2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:1.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "E68FE047-8F53-46B8-82D4-9342B1C8CA55",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_pni:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1353DC31-FB12-427A-B1B2-9164A4BEE14B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "B0A5CC25-A323-4D49-8989-5A417D12D646",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "A690BCD3-6497-43F7-8A51-E033B9121DC8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "AA375D44-ECC5-4BD3-A3D5-6D2AA68782D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update1:*:*:*:*:*:*",
              "matchCriteriaId": "6CD26C73-B61F-424B-91C2-352E2CAE6666",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_server:14.0:sp2_update2:*:*:*:*:*:*",
              "matchCriteriaId": "DB4EA15F-ECA4-477F-948F-490FC90BC66A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_opc_ua_server:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABA14E65-214C-431D-A49A-D8FC142D4541",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:tia_administrator:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "915B09CB-CA0A-445B-89D3-16AE9B08858E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253",
              "versionEndExcluding": "1.0.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "25A3180B-21AF-4010-9DAB-41ADFD2D8031",
              "versionEndIncluding": "10.12.0",
              "versionStartIncluding": "10.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "43B199B4-D89C-483D-ACAE-6CB2A59EE67C",
              "versionEndIncluding": "10.24.0",
              "versionStartIncluding": "10.13.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "564ED5C8-50D7-413A-B88E-E62B6C07336A",
              "versionEndIncluding": "12.12.0",
              "versionStartIncluding": "12.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "3DEBF7C8-B000-47B9-B597-DC440F2603B3",
              "versionEndExcluding": "12.22.1",
              "versionStartIncluding": "12.13.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "428DCD7B-6F66-4F18-B780-5BD80143D482",
              "versionEndIncluding": "14.14.0",
              "versionStartIncluding": "14.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:lts:*:*:*",
              "matchCriteriaId": "380D03F3-6A7E-43A2-B002-FB2521FD3C58",
              "versionEndExcluding": "14.16.1",
              "versionStartIncluding": "14.15.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:nodejs:node.js:*:*:*:*:-:*:*:*",
              "matchCriteriaId": "3ED4D313-F372-4CC1-BE11-6BBA2F0E90E3",
              "versionEndExcluding": "15.14.0",
              "versionStartIncluding": "15.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
    },
    {
      "lang": "es",
      "value": "Un servidor OpenSSL TLS puede cometer un fallo si un cliente env\u00eda un mensaje ClientHello de renegociaci\u00f3n dise\u00f1ado maliciosamente.\u0026#xa0;Si una renegociaci\u00f3n de TLSv1.2 ClientHello omite la extensi\u00f3n signature_algorithms (donde estaba presente en el ClientHello inicial), pero incluye una extensi\u00f3n signature_algorithms_cert, se producir\u00e1 una desreferencia del puntero NULL, lo que conllevar\u00e1 un bloqueo y un ataque de denegaci\u00f3n de servicio.\u0026#xa0;Un servidor solo es vulnerable si tiene TLSv1.2 y la renegociaci\u00f3n habilitada (que es la configuraci\u00f3n predeterminada).\u0026#xa0;Los clientes de OpenSSL TLS no est\u00e1n afectados por este problema.\u0026#xa0;Todas las versiones de OpenSSL versi\u00f3n 1.1.1 est\u00e1n afectadas por este problema.\u0026#xa0;Los usuarios de estas versiones deben actualizar a OpenSSL versi\u00f3n 1.1.1k.\u0026#xa0;OpenSSL versi\u00f3n 1.0.2 no est\u00e1 afectado por este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.1.1k (Afectadas versiones 1.1.1-1.1.1j)"
    }
  ],
  "id": "CVE-2021-3449",
  "lastModified": "2024-11-21T06:21:33.050",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-03-25T15:15:13.450",
  "references": [
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
    },
    {
      "source": "openssl-security@openssl.org",
      "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.gentoo.org/glsa/202103-03"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
    },
    {
      "source": "openssl-security@openssl.org",
      "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.debian.org/security/2021/dsa-4875"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.openssl.org/news/secadv/20210325.txt"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-05"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-06"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-09"
    },
    {
      "source": "openssl-security@openssl.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-10"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mailing List",
        "Third Party Advisory"
      ],
      "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.gentoo.org/glsa/202103-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.debian.org/security/2021/dsa-4875"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://www.openssl.org/news/secadv/20210325.txt"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-05"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-06"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-09"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.tenable.com/security/tns-2021-10"
    }
  ],
  "sourceIdentifier": "openssl-security@openssl.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-476"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2013-04-22 03:27
Modified
2024-11-21 01:48
Severity ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A37383F-B3F7-423C-B956-87926E38B323",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3D4A8F2-6ACC-4809-8320-7A0305741069",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EBDF670-EA1F-45A4-8C2B-C52B5D2AF565",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EC634AF-318C-4280-B0E3-1DE20C98962C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4A46E17-22DF-4FEB-B290-E209AF511B8E",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "233B1E82-769D-43AA-A051-CBAB0BD5F496",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CBD5520-7F19-44DE-AA9B-1D00475B987F",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E1B49EF-9276-47C7-ACE7-965B465BF202",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "919785E4-03B8-4BDF-9C3C-90538E24D13E",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port)."
    },
    {
      "lang": "es",
      "value": "Siemens SIMATIC S7-1200 PLCs v2.x y v3.x ermite a atacantes remotos causar una denegaci\u00f3n de servicios (transici\u00f3n de modo defecto e interrupci\u00f3n de control) a trav\u00e9s de paquetes TCP manipulados dirigidos al puerto 102 (conocido como puerto ISO-TSAP)."
    }
  ],
  "id": "CVE-2013-0700",
  "lastModified": "2024-11-21T01:48:01.540",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-04-22T03:27:13.047",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-08-13 19:15
Modified
2024-11-21 04:20
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFA8109D-F938-4FE3-9885-831D2D0FE058",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8AED132-C4CF-4C2E-B826-DFAE745256FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "621AC3EC-6DA3-4AA6-9100-0407EC8370E6",
              "versionEndIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F22D58C-444F-4179-B84F-24D57F4971EB",
              "versionEndIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "985A67F3-9799-4D30-B049-619456280DA4",
              "versionEndIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6A5E0374-939D-4C5E-B721-5AD8A3329387",
              "versionEndIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF7EA085-2297-4BA0-96AB-2A2EBE0BEFAF",
              "versionEndIncluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DF4F6EA7-68BD-4A9D-8DDC-1D802EA7905B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "33F882B8-EEDF-489E-9933-37EFC0AAC356",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9E8D52B-CDB3-4E26-A0C4-592CCBFBB827",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_net_pc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "744B5953-511F-42CA-80A0-DBE36A6AA144",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FA1684C0-4B7C-44A0-9F16-5F8121654397",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C9A3749-B092-4F92-8140-55F10A03A5DB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6D968D9-2A64-4E1C-824F-6508AEC6789D",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F96AD4B7-105A-4D60-9026-E5C6389F3C73",
              "versionEndExcluding": "16",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C3580BA-45F0-4A01-925F-D56B0BA058F7",
              "versionEndIncluding": "3.15",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:-:*:*:*:*:*:*",
              "matchCriteriaId": "84D652E6-23F7-4EB6-AE66-69662E191559",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_open_architecture:3.16:patch_12:*:*:*:*:*:*",
              "matchCriteriaId": "1F0B76B7-FCB4-4831-BD00-AF29FD4606B2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "29B1F502-8A3A-4C07-90D2-CE5EB06CB573",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*",
              "matchCriteriaId": "0384FFF2-F577-4FFC-8A84-5682771D1BC1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2DA2E87-7B96-4B6B-90F9-C22B138B441B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "581EA284-EDD6-4EA5-96B2-67904D1D9DC7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "95DEFB00-96A2-460F-8B59-A288FD154FDC",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEFDF765-44F4-45CB-8A28-FD7D355310DA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_panel_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE91BB69-3E42-4110-B49B-D53DB894E140",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_panel:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "35CA808F-891D-4E10-A87A-68440D0BE0CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC CP 1626 (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones anteriores a V20. 8), SIMATIC HMI Panel (incl. variantes SIPLUS) (Todas las versiones), SIMATIC NET PC Software V14 (Todas las versiones anteriores a V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.4.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.8.1), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V20.8), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V3.0), SIMATIC STEP 7 (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a V16), SIMATIC WinCC OA (Todas las versiones anteriores a V3. 16 P013), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a V16), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a V16), TIM 1531 IRC (incl. variantes de SIPLUS NET) (Todas las versiones anteriores a V2.1). Los dispositivos afectados contienen una vulnerabilidad de elusi\u00f3n de la protecci\u00f3n de mensajes debido a ciertas propiedades en el c\u00e1lculo utilizado para la protecci\u00f3n de la integridad. Esto podr\u00eda permitir a un atacante en posici\u00f3n de Man-in-the-Middle modificar el tr\u00e1fico de red enviado por el puerto 102/tcp a los dispositivos afectados"
    }
  ],
  "id": "CVE-2019-10929",
  "lastModified": "2024-11-21T04:20:10.487",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.2,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-08-13T19:15:14.860",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-327"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 06:31
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware *
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1200_cpu_12_1211c_firmware *
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware *
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware *
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware *
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1214fc_firmware *
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware *
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware *
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1217c_firmware *
siemens simatic_s7-1200_cpu_12_1217c -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens simatic_s7-1500_cpu_1507s_firmware *
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f_firmware *
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s_firmware *
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f_firmware *
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c_firmware *
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c_firmware *
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_151511c-1_firmware *
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware *
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518_firmware *
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_cpu_15pro-2_firmware *
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_15prof-2_firmware *
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc -
siemens simatic_s7-1500_software_controller_firmware -
siemens simatic_s7-1500_software_controller -
siemens siplus_tim_1531_irc_firmware -
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware -
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C9A0C34-9116-4835-8372-C72273B9CE08",
              "versionEndExcluding": "5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3C6CC47-5B8D-4FF7-B836-AB2C5C5D4189",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30B06ABC-30A2-4E3D-9A3C-E3B70308B427",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE09A9F-1EA2-4390-9648-61B2318EA930",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B64D841-42F1-4942-8568-A4E3B64A9711",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDF6B5E8-3B42-4E79-82CD-54112C819C0E",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E57A3D6-F939-49CB-85ED-319A9A447FF6",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D13B9DEC-0DC1-4F4B-9CD8-B0C4849EE0A7",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3BB3B1-5501-4044-9B10-64C7865E0B69",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54F1417-426E-45B2-AACA-D3A4EEDA162D",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6A37E51-044D-4420-98C5-FCE1C9FA0B77",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC3792E-C935-4AE9-B07F-C32F10072861",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "510EB4BE-7425-48C9-A3AB-B7932CFBCBC4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1452445-A671-463B-B175-07122B0D0F0A",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B89FB6F-4635-49B4-AF9C-17882F1D79E4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8722D9A2-C1AE-4B19-8827-A0BAE35BCEBC",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D74CF17-23D8-4F5F-8387-F9F751DFC37C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "689A662A-4CB4-40B6-946F-9ED223C929C8",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75D64AC3-E8AD-4906-836E-C6C0C77FDD7F",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFB7D20A-C951-467B-902F-C5B61AEE8722",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92D26AE4-A61C-4DDE-AC0E-7ADA6C16168C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37574513-3CE7-4A82-A495-272FDD01FADE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3A272D-45A1-4195-9B11-65D6BAACC425",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C48F5FEA-357C-4630-940F-06C7D175B8F2",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C73EC1A-3099-4099-AC21-2B5BA82B428E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85AECB2F-8AEC-4503-B45B-E32F6B081481",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A94DA11-E1EC-4792-8D08-D96C24EA60A7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1858266-384F-415E-AC75-9082729E80C0",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAD92A57-8592-4594-BAFE-BE50B9421EEA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28DAE724-8A2A-42EB-A407-FE3CC5E11303",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2923D75B-ACF8-47FF-859D-5F780CBF8A2B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79A2DD7B-FE32-4873-9689-64B34BD7A871",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17C0E003-6B46-4D32-9EF2-7EEC1E625534",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41E677CA-74B5-4281-816F-13B754EAEC85",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E60CDAF9-C304-4895-B60B-7BCE87B6AF62",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B209AD7-8F7D-4D8D-9C0E-ADBBBDF0D2D1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58B467A4-41F0-4CA3-9BE4-B5DBBE0B75A4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62A4DD30-1982-4126-8D18-9E9A18B88E52",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03CB600B-A8BD-4C13-940F-A7E22C732129",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F08F8454-11F2-4903-8845-17BA53092E99",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E8AD64D-AE4E-4E56-B64D-80C3FEB50839",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA9AF054-5D96-4C5D-87BA-73949C4D3BA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F18A96A0-C9C2-4F86-911A-FBEAB37D774E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A23DFA83-45DC-4FEE-9291-4B35487B2BEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "966ACB66-7F82-4784-9969-63F4B82385F7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "726B3940-F85B-4760-8C07-56C9B7EE6221",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C972215A-F45D-4730-80C9-72874221408C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AD40846-918D-4970-8FDC-4368CCD730D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5837F598-317F-48CE-AC05-2832F68DB71B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0B146AC-0BF0-42EF-9818-FEE8BC98197B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "60DEC18D-5A11-4CC4-9169-31130418A5E4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F89A4C42-7FC8-48B0-AC56-D5E5DC3771EF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1B00477-3871-4B60-94E2-93FDCAF2C921",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5983C923-9D2F-4888-8C7F-1F7C40F45B69",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE7EAEC5-1B73-4A47-81F8-18ADDF5E66A8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BA8F18C-446C-4795-B9EB-2213336F8DEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1B256C1-7476-437C-935F-B44E27589F37",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C9E1DB6-0613-479E-8215-7C8ED8736321",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06F09B1-5A87-4232-B604-A51445FF707E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F909702-CAD9-40F9-8CD0-1EAFB49EB108",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5A41226-5658-4871-9DA9-70802E0A939E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEF75D1-E68E-42F3-9A15-D31116854212",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "382C22D4-DB54-4AC9-9F31-0386264BE4DF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83F5D1D3-2452-47F8-85D6-24EF159342DA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DBE49-F5ED-46DC-B7B7-61C4624BD8D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A6E4A98-5656-4CCD-B41E-0413D1E0584D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2281F79-9098-4FEC-8303-3C426870BEE8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCD72B5F-10B0-4CF6-8498-8431384CDBA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA937CE7-4E65-45BA-8750-3498D3A4F4F4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "815E4D53-C0F4-4DE8-A9F9-998838D4E300",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66F5A4A6-D7F8-492C-A254-84F3EF3BDF1D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8C580F7-A436-4CDA-B273-A60EF5E7552C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92B4D260-9A8E-443B-8792-4FFD22137639",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF0FE9D-6A93-4F82-8CD7-0CB61079AC1C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2357ABBA-34A0-4D0D-8204-B47B29360574",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C1538F5-0FFE-4186-BB66-937CD0D1B5B3",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB41012B-98EF-4BF3-B103-F70F536E625E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18798AFB-14A8-412A-9886-71F403A888FC",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1475BB2A-72B0-44E1-9B0C-3D9DC61E8528",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "931D71AF-75B0-41BA-A0D8-C84EC4D5A350",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AA99065-A472-46E7-B65D-13424D3296BD",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E91666-3BEA-4F79-ACF0-F8FA58541E06",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490F5F0-3B3C-4501-AA0B-BED085534CB8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5513224-CDB4-4E7F-A296-131555F0CC93",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7803F3CE-F6DA-441C-A5AB-DE1FF0C56DF1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "755E97AB-6AD7-454D-9E35-3472B82A23F1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "214EDE7C-033D-4FB1-8FE1-17E99D7A9033",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA976CCF-1C34-461E-AEB3-DAEF0D251BDE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C665C2D3-80A3-4969-BABB-004B97A21B7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD7DA13A-BF1F-4501-A259-190BA4996B23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "820BF9F7-4283-4924-82F5-943172C32E2F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4068A0FB-8DAC-40AA-A016-5DE552EF20AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podr\u00eda permitir a un atacante provocar una denegaci\u00f3n de servicio en el dispositivo."
    }
  ],
  "id": "CVE-2021-44694",
  "lastModified": "2024-11-21T06:31:23.633",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 5.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 4.2,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-12-13T16:15:14.840",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1287"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-09 16:15
Modified
2024-11-21 06:14
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (Todas las versiones anteriores a la versi\u00f3n V2.9.2), la familia SIMATIC Drive Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS) (Todas las versiones), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (Todas las versiones), Familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V4.5. 0), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5.2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a la versi\u00f3n V2.9.2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9. 4), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versi\u00f3n V21.9), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a la versi\u00f3n V4.0), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda causar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar un paquete especialmente preparado sobre el puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal"
    }
  ],
  "id": "CVE-2021-37204",
  "lastModified": "2024-11-21T06:14:51.340",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-02-09T16:15:13.333",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-672"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-09 16:15
Modified
2024-11-21 06:14
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5. 2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar paquetes especialmente preparados a trav\u00e9s del puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal"
    }
  ],
  "id": "CVE-2021-37185",
  "lastModified": "2024-11-21T06:14:48.977",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-02-09T16:15:12.823",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-672"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-08-13 19:15
Modified
2024-11-21 04:20
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFA8109D-F938-4FE3-9885-831D2D0FE058",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8AED132-C4CF-4C2E-B826-DFAE745256FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B4A8C4A-8AED-42A4-BF49-C1F9E9A48EBD",
              "versionEndExcluding": "20.8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0812843-6B21-4622-8C97-D87162987434",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEBF07D2-1CFB-4769-8F4D-59737D782B9B",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "99C1E616-6A34-4C85-927B-29C53A0BA873",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB22A001-A28B-48D2-93BE-95C3EBD39A8D",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7CFDEA0C-BE3D-425B-B5FD-299C93C70CD8",
              "versionEndExcluding": "4.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85BF9FC3-FF9D-4E14-8D3F-A7AA9CC84A48",
              "versionEndExcluding": "2.8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E18897A5-B757-412B-A28A-E8BD9CA73520",
              "versionEndExcluding": "2.8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87628F0C-73A3-4169-A58E-18538AD88C8C",
              "versionEndExcluding": "2.8.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D31E1129-2A71-4130-A32B-0E5A437D4C07",
              "versionEndExcluding": "20.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7_plcsim_advanced:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FCB3DDD9-64F2-4A38-A9E8-2D8AA09F403D",
              "versionEndExcluding": "3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
    },
    {
      "lang": "es",
      "value": "SIPLUS) (Todas las versiones anteriores a V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. variantes SIPLUS) (Todas las versiones posteriores o iguales V20.8), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones anteriores a V4.4.0), familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS) (Todas las versiones variantes SIPLUS) (Todas las versiones posteriores o iguales V4.4.0), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones anteriores a V2.8.1), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales V2. 8.1), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a V20.8), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales V20.8), SIMATIC S7-PLCSIM Advanced (Todas las versiones anteriores a V3.0), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales V3.0). Un atacante con acceso de red al puerto 102/tcp podr\u00eda modificar potencialmente el programa de usuario en el PLC de manera que el c\u00f3digo en ejecuci\u00f3n sea diferente del c\u00f3digo fuente que est\u00e1 almacenado en el dispositivo. Un atacante debe tener acceso de red a los dispositivos afectados y debe ser capaz de realizar cambios en el programa de usuario. La vulnerabilidad podr\u00eda afectar a la integridad percibida del programa de usuario almacenado en la CPU. Un ingeniero que intente obtener el c\u00f3digo del programa de usuario que se ejecuta en el dispositivo, puede recibir un c\u00f3digo fuente diferente que no se est\u00e1 ejecutando realmente en el dispositivo"
    }
  ],
  "id": "CVE-2019-10943",
  "lastModified": "2024-11-21T04:20:12.313",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-08-13T19:15:15.530",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-353"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-345"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2012-09-25 11:07
Modified
2024-11-21 01:40
Severity ?
Summary
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBAF9260-5746-469B-AAB3-66F12108A610",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1476AD3-CF60-462E-9EEF-616A1B510F88",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5A19DB02-8D64-4044-97BD-6769F3CE6AE5",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "406EC119-4B43-4AFD-9BC9-FE86E2F57F51",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A162C46-AB20-41EB-B76F-799BCEAF66F9",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "82B37AFD-DCE1-4244-BB70-1DCDA91B82C1",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "147E133F-E99A-4DDA-A77B-E3EAC59AB2EE",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8861261D-7153-4D30-8614-BA67BB3888C0",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F5277B1-273F-4138-9C29-D2E25C6C21F1",
              "versionEndExcluding": "3.0.0",
              "versionStartIncluding": "2.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate."
    },
    {
      "lang": "es",
      "value": "El PLC siemens SIMATIC S7-1200 2.x no protege de forma adecuada la clave privada del certificado de SIMATIC CONTROLLER Certification Authority, lo que permitir\u00eda a atacantes remotos espiar el servidor Web S7-1200 usando esta clave para crear certificados falsificados."
    }
  ],
  "id": "CVE-2012-3037",
  "lastModified": "2024-11-21T01:40:09.607",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2012-09-25T11:07:46.470",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://en.securitylab.ru/lab/PT-2012-48"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "http://en.securitylab.ru/lab/PT-2012-48"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-295"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-02-09 16:15
Modified
2024-11-21 06:14
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
siemens simatic_drive_controller_cpu_1504d_tf_firmware *
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware *
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware *
siemens simatic_et_200sp_open_controller_cpu_1515sp_pc2 -
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced_firmware 4.0
siemens simatic_s7-plcsim_advanced -
siemens tim_1531_irc_firmware *
siemens tim_1531_irc -
siemens simatic_s7-1500_software_controller *
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D04FDFA5-E309-400F-B6BD-009D0540CC58",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6DC0350F-C61E-46B0-B8D2-278DBFF5FE07",
              "versionEndExcluding": "2.9.4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C59DF55E-2F4F-4BF1-B02F-05916BC863D4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_open_controller_cpu_1515sp_pc2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E3491F-8F4A-4C7D-960D-073AA41DB4D6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5316C6A1-A9D6-4B03-B6D1-402803DE156C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:4.0:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7606D9B-40D9-4FC1-BFC1-2102D7D0E216",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "34AEEAA6-3D7E-4A57-99C7-CA51C65DE6AB",
              "versionStartIncluding": "2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A484657A-315A-420D-B871-690A812A25D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "619B6E3D-04CF-488C-B683-DD41E8FA5A49",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2F56E7C9-0CDD-4C38-940E-C1F868972477",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B040DCD8-5290-4D0F-811F-C66B23251A1C",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4B4D0E9-7D6D-429B-954D-BED796A48EE8",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC90834-F984-40D4-AD4A-1AFC0B8CFEE0",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0DC58EB9-EE55-4A93-B0C0-9D8080A7272D",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "13513190-F039-44CC-9314-CD92A31CD913",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06796C2-880A-4B24-A3F5-45765395954E",
              "versionEndExcluding": "4.5.2",
              "versionStartIncluding": "4.5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "97BBB092-E84B-400A-8C23-6ACACE2166DA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AC2B179-74D4-4501-87DC-9453668B0380",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0CC67852-31C7-4AD8-BFAE-21185A9032B1",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DA4FA4-4A3D-485E-B7AF-A99D200FEB95",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9EBF937-C08A-481E-A78F-5F1867E8CA72",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "479FD9DE-11AD-4E0D-A156-7AEAAB413340",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0B8442FF-5CC9-4375-8CA0-4C40AC9BF3D6",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41110BB6-35DE-474B-9737-F52D3DFEFE74",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "850183B0-B28F-4DE4-B946-1A8CEAC8405E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "643F8228-B027-4142-96AE-D0634214B558",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE79E08-3046-463B-A435-5E9CDEA1D065",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FC37C005-A9C2-4C41-A588-4C55D4B98E2E",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66AFEF4C-943F-4B28-8ADC-56471309D7EA",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84A8E248-282C-4B42-82C2-54C6FE3F5193",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D414FDF2-8988-4DAD-AA26-2E6263DE55FB",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D97466FA-5887-401B-8BAA-7B12E13E8670",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "46C7835E-2D0F-42FF-AF4F-D1BEB7CFC75D",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B8659AE-88B8-4318-AA52-893C72388CF9",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79D97556-8B12-46AD-BCF7-42FD9DAB8F3F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "407FC394-6B95-455D-B80D-2B5025684C08",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FBA4611-1221-4BEF-821B-29549044F8C0",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "687833D7-43E0-48CD-BC55-D33BD4654E2A",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C255DAA6-F418-40F1-B47C-FAA18152D648",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "47825870-52BD-4EDC-81D0-79DAAA39A9D7",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "69C5BA5B-C58A-496C-88E5-496CCD55DF5B",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "398DC87E-ED2D-44BC-A5F0-A6FA6E560A88",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C746F486-CCAB-4D23-8770-8D68659DB5B5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9A5802D-E81B-41D9-85D1-E704DBD84EBE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4730FD89-CBE6-46AF-ACDA-6F987264BDA5",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "35C381B9-8DD5-400B-8E06-DA7ACCC67C52",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "12D8E98F-AF8D-490E-98A3-00036CF83407",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85594ACB-69DF-4D28-BB19-9F024D5D0D55",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A140FAD2-0FC5-4695-8A13-D6C57777F93F",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4426EBD2-DB73-4811-9550-68E77F479DDE",
              "versionEndExcluding": "2.9.4",
              "versionStartIncluding": "2.9.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la familia de controladores de accionamiento SIMATIC (todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), la familia de CPU SIMATIC S7-1200 (incluidas las variantes SIPLUS) (todas las versiones posteriores o iguales a la versi\u00f3n V4.5.0 anteriores a la versi\u00f3n V4.5. 2), familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.9.2 anteriores a la versi\u00f3n V2.9.4), SIMATIC S7-1500 Software Controller (Todas las versiones posteriores o iguales a la versi\u00f3n V21.9 anteriores a la versi\u00f3n V21.9.4), SIMATIC S7-PLCSIM Advanced (Todas las versiones posteriores o iguales a la versi\u00f3n V4.0 anteriores a la versi\u00f3n V4.0 SP1), TIM 1531 IRC (incl. variantes SIPLUS NET) (Todas las versiones posteriores o iguales a la versi\u00f3n V2.2). Un atacante no autenticado podr\u00eda provocar una condici\u00f3n de denegaci\u00f3n de servicio en un PLC al enviar paquetes especialmente preparados a trav\u00e9s del puerto 102/tcp. Es necesario reiniciar el dispositivo afectado para restablecer el funcionamiento normal anteriores a la versi\u00f3n"
    }
  ],
  "id": "CVE-2021-37205",
  "lastModified": "2024-11-21T06:14:51.527",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.1,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-02-09T16:15:13.393",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-401"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 06:31
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware *
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1200_cpu_12_1211c_firmware *
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware *
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware *
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware *
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1214fc_firmware *
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware *
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware *
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1217c_firmware *
siemens simatic_s7-1200_cpu_12_1217c -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens simatic_s7-1500_cpu_1507s_firmware *
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f_firmware *
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s_firmware *
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f_firmware *
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c_firmware *
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c_firmware *
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_151511c-1_firmware *
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware *
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518_firmware *
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_cpu_15pro-2_firmware *
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_15prof-2_firmware *
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc -
siemens simatic_s7-1500_software_controller_firmware -
siemens simatic_s7-1500_software_controller -
siemens siplus_s7-300_cpu_314_firmware -
siemens siplus_s7-300_cpu_314 -
siemens siplus_s7-300_cpu_315-2_dp_firmware -
siemens siplus_s7-300_cpu_315-2_dp -
siemens siplus_s7-300_cpu_315-2_pn\/dp_firmware -
siemens siplus_s7-300_cpu_315-2_pn\/dp -
siemens siplus_s7-300_cpu_317-2_pn\/dp_firmware -
siemens siplus_s7-300_cpu_317-2_pn\/dp v6
siemens siplus_tim_1531_irc_firmware -
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware -
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C9A0C34-9116-4835-8372-C72273B9CE08",
              "versionEndExcluding": "5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3C6CC47-5B8D-4FF7-B836-AB2C5C5D4189",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30B06ABC-30A2-4E3D-9A3C-E3B70308B427",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE09A9F-1EA2-4390-9648-61B2318EA930",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B64D841-42F1-4942-8568-A4E3B64A9711",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDF6B5E8-3B42-4E79-82CD-54112C819C0E",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E57A3D6-F939-49CB-85ED-319A9A447FF6",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D13B9DEC-0DC1-4F4B-9CD8-B0C4849EE0A7",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3BB3B1-5501-4044-9B10-64C7865E0B69",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54F1417-426E-45B2-AACA-D3A4EEDA162D",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6A37E51-044D-4420-98C5-FCE1C9FA0B77",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC3792E-C935-4AE9-B07F-C32F10072861",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "510EB4BE-7425-48C9-A3AB-B7932CFBCBC4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1452445-A671-463B-B175-07122B0D0F0A",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B89FB6F-4635-49B4-AF9C-17882F1D79E4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8722D9A2-C1AE-4B19-8827-A0BAE35BCEBC",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D74CF17-23D8-4F5F-8387-F9F751DFC37C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "689A662A-4CB4-40B6-946F-9ED223C929C8",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75D64AC3-E8AD-4906-836E-C6C0C77FDD7F",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFB7D20A-C951-467B-902F-C5B61AEE8722",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92D26AE4-A61C-4DDE-AC0E-7ADA6C16168C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37574513-3CE7-4A82-A495-272FDD01FADE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3A272D-45A1-4195-9B11-65D6BAACC425",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C48F5FEA-357C-4630-940F-06C7D175B8F2",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C73EC1A-3099-4099-AC21-2B5BA82B428E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85AECB2F-8AEC-4503-B45B-E32F6B081481",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A94DA11-E1EC-4792-8D08-D96C24EA60A7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1858266-384F-415E-AC75-9082729E80C0",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAD92A57-8592-4594-BAFE-BE50B9421EEA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28DAE724-8A2A-42EB-A407-FE3CC5E11303",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2923D75B-ACF8-47FF-859D-5F780CBF8A2B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79A2DD7B-FE32-4873-9689-64B34BD7A871",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17C0E003-6B46-4D32-9EF2-7EEC1E625534",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41E677CA-74B5-4281-816F-13B754EAEC85",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E60CDAF9-C304-4895-B60B-7BCE87B6AF62",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B209AD7-8F7D-4D8D-9C0E-ADBBBDF0D2D1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58B467A4-41F0-4CA3-9BE4-B5DBBE0B75A4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62A4DD30-1982-4126-8D18-9E9A18B88E52",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03CB600B-A8BD-4C13-940F-A7E22C732129",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F08F8454-11F2-4903-8845-17BA53092E99",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E8AD64D-AE4E-4E56-B64D-80C3FEB50839",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA9AF054-5D96-4C5D-87BA-73949C4D3BA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F18A96A0-C9C2-4F86-911A-FBEAB37D774E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A23DFA83-45DC-4FEE-9291-4B35487B2BEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "966ACB66-7F82-4784-9969-63F4B82385F7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "726B3940-F85B-4760-8C07-56C9B7EE6221",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C972215A-F45D-4730-80C9-72874221408C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AD40846-918D-4970-8FDC-4368CCD730D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5837F598-317F-48CE-AC05-2832F68DB71B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0B146AC-0BF0-42EF-9818-FEE8BC98197B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "60DEC18D-5A11-4CC4-9169-31130418A5E4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F89A4C42-7FC8-48B0-AC56-D5E5DC3771EF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1B00477-3871-4B60-94E2-93FDCAF2C921",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5983C923-9D2F-4888-8C7F-1F7C40F45B69",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE7EAEC5-1B73-4A47-81F8-18ADDF5E66A8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BA8F18C-446C-4795-B9EB-2213336F8DEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1B256C1-7476-437C-935F-B44E27589F37",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C9E1DB6-0613-479E-8215-7C8ED8736321",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06F09B1-5A87-4232-B604-A51445FF707E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F909702-CAD9-40F9-8CD0-1EAFB49EB108",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5A41226-5658-4871-9DA9-70802E0A939E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEF75D1-E68E-42F3-9A15-D31116854212",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "382C22D4-DB54-4AC9-9F31-0386264BE4DF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83F5D1D3-2452-47F8-85D6-24EF159342DA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DBE49-F5ED-46DC-B7B7-61C4624BD8D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A6E4A98-5656-4CCD-B41E-0413D1E0584D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2281F79-9098-4FEC-8303-3C426870BEE8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCD72B5F-10B0-4CF6-8498-8431384CDBA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA937CE7-4E65-45BA-8750-3498D3A4F4F4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "815E4D53-C0F4-4DE8-A9F9-998838D4E300",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66F5A4A6-D7F8-492C-A254-84F3EF3BDF1D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8C580F7-A436-4CDA-B273-A60EF5E7552C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92B4D260-9A8E-443B-8792-4FFD22137639",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF0FE9D-6A93-4F82-8CD7-0CB61079AC1C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2357ABBA-34A0-4D0D-8204-B47B29360574",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C1538F5-0FFE-4186-BB66-937CD0D1B5B3",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB41012B-98EF-4BF3-B103-F70F536E625E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18798AFB-14A8-412A-9886-71F403A888FC",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1475BB2A-72B0-44E1-9B0C-3D9DC61E8528",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "931D71AF-75B0-41BA-A0D8-C84EC4D5A350",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AA99065-A472-46E7-B65D-13424D3296BD",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E91666-3BEA-4F79-ACF0-F8FA58541E06",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490F5F0-3B3C-4501-AA0B-BED085534CB8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5513224-CDB4-4E7F-A296-131555F0CC93",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7803F3CE-F6DA-441C-A5AB-DE1FF0C56DF1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "755E97AB-6AD7-454D-9E35-3472B82A23F1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "214EDE7C-033D-4FB1-8FE1-17E99D7A9033",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA976CCF-1C34-461E-AEB3-DAEF0D251BDE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C665C2D3-80A3-4969-BABB-004B97A21B7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD7DA13A-BF1F-4501-A259-190BA4996B23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "83900616-A91E-45B2-AE17-1D68E1B8BA57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88F00AE1-D55A-4C7C-A421-2B89BDFE4C9D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A856E00C-965C-478F-A6D8-79EDCF342DDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D038857-CED3-4312-9B86-36DC10A0398F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_315-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61D2CA3D-D97B-4AC7-AAA7-F2444667B74B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_315-2_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FC6FF34-3155-4CF8-88D5-4EAE00B32163",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88CEE87A-2A0D-45E9-967E-F88EC87EE687",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_317-2_pn\\/dp:v6:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5CDFEA-E5F2-419F-A1B3-D98C44D38D84",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "820BF9F7-4283-4924-82F5-943172C32E2F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4068A0FB-8DAC-40AA-A016-5DE552EF20AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podr\u00eda permitir a un atacante provocar una denegaci\u00f3n de servicio en el dispositivo."
    }
  ],
  "id": "CVE-2021-44695",
  "lastModified": "2024-11-21T06:31:24.237",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 4.9,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-12-13T16:15:14.907",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-1286"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-11-08 11:15
Modified
2024-11-21 07:03
Summary
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
Impacted products
Vendor Product Version
siemens simatic_s7-1500_software_controller -
siemens simatic_s7-plcsim_advanced -
siemens simatic_wincc_runtime -
siemens 6es7154-8fb01-0ab0_firmware *
siemens 6es7154-8fb01-0ab0 -
siemens 6es7154-8ab01-0ab0_firmware *
siemens 6es7154-8ab01-0ab0 -
siemens 6es7154-8fx00-0ab0_firmware *
siemens 6es7154-8fx00-0ab0 -
siemens 6es7151-8ab01-0ab0_firmware *
siemens 6es7151-8ab01-0ab0 -
siemens 6es7151-8fb01-0ab0_firmware *
siemens 6es7151-8fb01-0ab0 -
siemens 6es7314-6eh04-0ab0_firmware *
siemens 6es7314-6eh04-0ab0 -
siemens 6es7315-2eh14-0ab0_firmware *
siemens 6es7315-2eh14-0ab0 -
siemens 6es7315-2fj14-0ab0_firmware *
siemens 6es7315-2fj14-0ab0 -
siemens 6es7315-7tj10-0ab0_firmware *
siemens 6es7315-7tj10-0ab0 -
siemens 6es7317-2ek14-0ab0_firmware *
siemens 6es7317-2ek14-0ab0 -
siemens 6es7317-2fk14-0ab0_firmware *
siemens 6es7317-2fk14-0ab0 -
siemens 6es7317-7tk10-0ab0_firmware *
siemens 6es7317-7tk10-0ab0 -
siemens 6es7317-7ul10-0ab0_firmware *
siemens 6es7317-7ul10-0ab0 -
siemens 6es7318-3el01-0ab0_firmware *
siemens 6es7318-3el01-0ab0 -
siemens 6es7318-3fl01-0ab0_firmware *
siemens 6es7318-3fl01-0ab0 -
siemens 6ag1151-8ab01-7ab0_firmware *
siemens 6ag1151-8ab01-7ab0 -
siemens 6ag1151-8fb01-2ab0_firmware *
siemens 6ag1151-8fb01-2ab0 -
siemens 6ag1314-6eh04-7ab0_firmware *
siemens 6ag1314-6eh04-7ab0 -
siemens 6ag1315-2eh14-7ab0_firmware *
siemens 6ag1315-2eh14-7ab0 -
siemens 6ag1315-2fj14-2ab0_firmware *
siemens 6ag1315-2fj14-2ab0 -
siemens 6ag1317-2ek14-7ab0_firmware *
siemens 6ag1317-2ek14-7ab0 -
siemens 6ag1317-2fk14-2ab0_firmware *
siemens 6ag1317-2fk14-2ab0 -
siemens sinumerik_one_firmware -
siemens sinumerik_one -
siemens simatic_pcs_firmware *
siemens simatic_pcs -
siemens simatic_drive_controller_cpu_1504d_tf_firmware -
siemens simatic_drive_controller_cpu_1504d_tf -
siemens simatic_drive_controller_cpu_1507d_tf_firmware -
siemens simatic_drive_controller_cpu_1507d_tf -
siemens simatic_s7-400_pn\/dp_v7_firmware -
siemens simatic_s7-400_pn\/dp_v7 -
siemens simatic_s7-400_pn\/dp_v6_firmware -
siemens simatic_s7-400_pn\/dp_v6 -
siemens simatic_s7-1500_cpu_1507s_firmware -
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f_firmware -
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s_firmware -
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f_firmware -
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp_firmware -
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1_firmware -
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1_firmware -
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn_firmware -
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c_firmware -
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1_firmware -
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware -
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn_firmware -
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1_firmware -
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware -
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c_firmware -
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1_firmware -
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware -
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware -
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware -
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn_firmware -
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1_firmware -
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn_firmware -
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1_firmware -
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_151511c-1_firmware -
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware -
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1515-2_firmware -
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn_firmware -
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_1515f-2_firmware -
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn_firmware -
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2_firmware -
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware -
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware -
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware -
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp_firmware -
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn_firmware -
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3_firmware -
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro_f_firmware -
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516pro-2_firmware -
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516t-3_firmware -
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware -
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware -
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp_firmware -
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn_firmware -
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3_firmware -
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3_firmware -
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518_firmware -
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4_firmware -
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp_firmware -
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn_firmware -
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4_firmware -
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4_firmware -
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware -
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware -
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_cpu_15pro-2_firmware -
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_15prof-2_firmware -
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware -
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware -
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens simatic_s7-1200_cpu_12_1211c_firmware -
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware -
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware -
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware -
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1214fc_firmware -
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware -
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware -
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1217c_firmware -
siemens simatic_s7-1200_cpu_12_1217c -
siemens simatic_s7-1200_cpu_1211c_firmware -
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware -
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware -
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware -
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware -
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc_firmware -
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware -
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware -
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc_firmware -
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c_firmware -
siemens simatic_s7-1200_cpu_1217c -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D089914D-13D3-4346-82C3-303C1D1023F5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6584B524-B508-4B21-B0B3-40F41B4A6EAA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*",
              "matchCriteriaId": "1116304B-6CD9-4D44-BC95-B945D82873A4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7154-8fb01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA0474B6-F38C-4B1E-9ADA-3F0270C47E7C",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7154-8fb01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A0248D0-EF8E-4AD1-ABBF-8D1B7ED5F08C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7154-8ab01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24ACA600-CC4E-4252-BC75-1F1D44D30417",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7154-8ab01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C2DC1DE-A7FC-42F2-B5A7-6BB98A94E6EA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7154-8fx00-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0919DB8-4142-46E4-81AB-AF945441F9CE",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7154-8fx00-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8252730-0DD4-4F77-95CC-92907244F4E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7151-8ab01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "435258BB-C910-4ED3-81A5-91B8F5CC6B8D",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7151-8ab01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4992DF18-3BD8-47B4-A36F-8557C33948D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7151-8fb01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCE82634-A022-4F94-85A5-AF2BD98E31CD",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7151-8fb01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE90BEC1-198E-4134-A14D-2D8D1673168C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7314-6eh04-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2404CD50-DA2D-4FB0-8387-3BD1AEE77719",
              "versionEndExcluding": "3.3.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7314-6eh04-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "577E4267-C1E8-4DBD-BADF-ABCD7234665A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7315-2eh14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8683C7D7-BEE8-4DA5-9F45-D15BD9E48C13",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7315-2eh14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "36FD5746-7B92-4931-8581-2421BAEB4A88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7315-2fj14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EF9DC4C-441D-4685-8996-C1155458DC01",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7315-2fj14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "94FE624E-CB3E-4ADE-AEB0-21BDA4FC64D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7315-7tj10-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8E36044-A4DA-4F93-AE32-32152C88B4B2",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7315-7tj10-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFA14E2D-A82F-4D52-9F25-1A4AA1957075",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-2ek14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2955CED-04B2-4C6B-9FF0-2AFD4F6AFC49",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-2ek14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1AC60B6-6D26-42A5-A6C0-EFD5467D1F7B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-2fk14-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E384CF1-4153-41E7-A87C-97F68EEB10E2",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-2fk14-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "372CDCD9-1F1A-428B-9515-EC81A8A9AC9C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-7tk10-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CEF1C2CA-067A-4C66-853F-67643E7AECB6",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-7tk10-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "23184657-CB41-4CE2-BD72-54AD4CD63ECE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7317-7ul10-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54BAA07B-EC8F-466A-8E75-860A775299ED",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7317-7ul10-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA8D0755-4E3A-4D43-98A0-E1CCE615B3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7318-3el01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A738D3BB-BF24-46D4-BC92-ED40FAF68EE0",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7318-3el01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2529D87B-E231-4405-8148-5E176B5D4F5F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6es7318-3fl01-0ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3439CE01-CB66-4D43-8452-07F972B7A7C6",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6es7318-3fl01-0ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "20AA01A1-14BF-4235-BDD4-597CA5233CE7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1151-8ab01-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "48C207AB-B37C-4E9C-87EE-54358EFE7FC3",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1151-8ab01-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C1563C8-40FB-4FF7-B55B-F49CBF7D59D2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1151-8fb01-2ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B929316E-5032-458F-A823-913D6D2EC392",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1151-8fb01-2ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "56A96DA1-9C0D-4075-89BD-BA0C107A6DBD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1314-6eh04-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C4EADDE-7879-4189-8469-0085422D8318",
              "versionEndExcluding": "3.3.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1314-6eh04-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F94C405-65D0-41E1-9A49-1BA424D26C2F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1315-2eh14-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE92915A-271A-4B25-B5AA-BFD19DF3802A",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1315-2eh14-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB350474-986A-4829-81AB-139AE1D41731",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1315-2fj14-2ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEAEC33F-6CA0-4D96-9DA7-52F113ED9422",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1315-2fj14-2ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9C9973D1-F914-4970-9584-DBA849B5A374",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1317-2ek14-7ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "64F7BBCD-B399-4E4C-9841-B52279F368C3",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1317-2ek14-7ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9835211F-F261-43F2-8EE2-C09E0BA64A7F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:6ag1317-2fk14-2ab0_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6BA0546-F5A4-4440-9C3F-FA2A5F3581C5",
              "versionEndExcluding": "3.2.19",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:6ag1317-2fk14-2ab0:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C2EF3C6-D468-4664-A4D9-F1B342746825",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinumerik_one_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4FADF6B2-FFE7-4C4E-BF93-61CAA9368285",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinumerik_one:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE30FFDF-5494-400D-8F88-954A6B1503B9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pcs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "00961925-0D80-48C3-BD84-7D4ECF30BCE8",
              "versionEndIncluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pcs:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5BEAC421-FE31-4F16-8DB1-B816FDD66D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1504d_tf_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE44BAF7-B9D7-460E-BA76-9405CBC775A8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1504d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D3A69023-E9FF-4947-81D2-5374F0D17E02",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_drive_controller_cpu_1507d_tf_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "65963CEF-7071-4D1C-B6BB-EB56909C55E3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_drive_controller_cpu_1507d_tf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6D49FAA-BB5E-4B55-9C11-B840676FEC97",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v7_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A1E779F-1A56-4552-9E82-F881D3B044C0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "915E168D-2DF4-4D25-85AC-3684C30985BC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn\\/dp_v6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C27A6138-1536-4BCD-B072-B64767140F1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDBDA792-481E-4728-8089-E0E3CF78FCDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6999D835-F9A7-46BA-BF40-39F11F50DBDA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F946597D-56D1-4F84-B49A-031D2B6C6A75",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6B78A081-E63E-4712-B3D1-D077CC2ADA39",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F419FF16-E351-4881-939C-1FAE5783F18C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "306030D2-62E7-4E2C-BABB-9BEA2902F859",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D65CD4C-49ED-4BE6-A166-E30B107B508D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EEAB4D7D-BBA9-462F-9801-43B968FED148",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5007FF6-07A4-4C39-A96A-FBA4E64E6C5B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7C8D3003-82C6-4D59-A1ED-6897239C62E0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA23E9EB-5344-4DBE-81DB-076F310C25C8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3456E2BC-7BF0-4B5B-A8D8-D51E5CED2EA4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AEEF32EA-F142-42AE-AF7D-CCF026247D67",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D4BD169-6330-44CE-86F2-05F625A805F8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE580163-01B8-45EF-8374-7F18131DE91D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C548EAC7-F5FC-40DA-8A5B-4701848036C5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDA4B714-930D-48C8-B8F5-AEDBD32ED70F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C65CBECB-B847-4CDB-B5EE-C5CA9650D233",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B284524-2483-479E-8DB0-2F867C2D94D8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE709858-D53C-4130-BC22-93859394BBDC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61E05B43-EB9C-4CDA-A166-21D6A3BF9CA6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE2E6369-80E6-435B-81EE-2CA619DB2792",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6ACD393E-404B-441C-A86D-138116A3D235",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8C752CB-BBB9-4B3E-A0D2-7BEDBF1E1CAF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CA67D2-620A-4C1A-9D03-3D8D632E6054",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B921D252-AD63-4CA0-BBF7-EB825BFB6F8E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4899D5A4-2FDD-4594-8BEC-40B1C06F7912",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B3F212F8-899F-4A6B-A5E7-448EF6B0FF9F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "59B6BB2D-602C-4C21-9CF7-E458CB16A85A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C2BABE44-5947-4B73-B7F9-CDBFEF75D48E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C482E94F-DCB8-4C5F-9C02-329168201FEB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "75108BD0-208A-4D6C-9725-024E8B473DF7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "59AB9211-C748-4519-A10E-2BDD86E9DB3B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1F9332E-41DC-491E-A4EE-7F19EB868B8D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7B89339-2A37-48A1-BD48-1D0A9606B633",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "941EA204-0ACC-4530-8DD7-8EE13B838E43",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "394B61E8-68E5-4E18-BCD8-5CF0A03F5562",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D0D14325-65B6-4E52-9CF1-9747718E6999",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE7B8BBC-0424-4819-BCB2-F7AA151342F1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B73DC49-C581-49C1-9B97-E63B976A2B2E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49A379BF-8C3B-4C53-ADD4-D718F54FBE8C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "48747971-E3B6-4777-AE36-3868CCE063FC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ADC9BBE9-49EC-495D-A77C-621D162B601E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "97CF55DA-622C-4449-BF4B-CA2943E931B8",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8360B6F2-8A2C-4D01-B041-DF8447515B98",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "31B6D71B-05F8-47D6-9E98-11BA5C118322",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "163D5E50-9D3D-4823-86D8-AB20750FF98D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF0659BF-0AAB-4689-8B66-C934E32882CB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8B7D515C-3885-48DB-879C-B963A95482F5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A7986DD-B46E-46E3-AC4A-A2E6AF062451",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A16F6A0-ED34-4207-AD95-C3F08B8ABFF0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0E73EBA-AE4E-4263-B221-3F30056C0589",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A90C920C-B31C-48E6-A01A-A28DFF5B5AFD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "105DF0A7-88CD-4145-97D1-37301C98FCD6",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "79DE73E2-10CF-4E36-B78A-87C9846B4EEC",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4F5BF77-21E0-4F5D-A22C-FCD8D3FD33C3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F610BF59-5390-4D3C-B082-387CEDF3C75D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B8FD1F65-2581-465F-A0F1-FDD792A00300",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "728DE10E-6915-4015-B899-DA21AE885525",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A55BEA90-A2CD-4E13-BCE2-202BF9CB0630",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9CB4F9CD-DABF-41B1-9A33-8E2F38AFD171",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C58021F0-40C6-4066-834A-C6F5679CC2BA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7A0687E-BD56-472F-8AC4-A8C8846F2E9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E7578C6-9149-4742-99FF-CB13CEAE8214",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDA87A40-D438-4ABF-9021-AE5672AC25FB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "16E49567-1928-42C1-B8AC-CE283E0276E2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "91914E86-2313-46DD-B462-E9C0221B0573",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AA5A765-6D88-4DBB-8171-4BEFD52EF346",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "14993EB3-1896-4040-A05D-CAA3B4CC1466",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD85CC9A-F8F0-436E-B2D4-DD719C482C04",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1453CB1-C229-4998-BC19-98CA1146B5D5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5477E1A-E37D-483D-B285-7C69538406B4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F179B6C7-9F46-49A2-A5E5-E60A49632981",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D43A3548-B4B4-4D05-BBD6-59A4FA43CFF1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "47046130-C64B-40D5-B661-19E031B83529",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27A07E24-A6CB-4B74-B35A-EFB3D7E91FB3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE9D91E3-7696-49F9-812D-F4816BD9F655",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBD3361A-95E0-4F8C-B1F8-DDA2DA03805B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C91C60D-1770-4972-A476-EE8BAF31EFFF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78B5E474-2B55-491F-9BBD-5341614E2A5F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5679CB0-7C93-4260-BF17-11C4CF56A723",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5220CCF-F39B-45C5-8C60-584412A38583",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack."
    },
    {
      "lang": "es",
      "value": "El endpoint de inicio de sesi\u00f3n /FormLogin en los servicios web afectados no aplica la verificaci\u00f3n de origen adecuada. Esto podr\u00eda permitir a atacantes remotos autenticados rastrear las actividades de otros usuarios mediante un ataque de Cross-Site Request Forgery (CSRF)."
    }
  ],
  "id": "CVE-2022-30694",
  "lastModified": "2024-11-21T07:03:11.067",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 3.5,
          "baseSeverity": "LOW",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-11-08T11:15:10.413",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2019-10-10 14:15
Modified
2024-11-21 04:20
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Impacted products
Vendor Product Version
siemens dk_standard_ethernet_controller_firmware *
siemens dk_standard_ethernet_controller -
siemens ek-ertec_200_firmware *
siemens ek-ertec_200 -
siemens ek-ertec_200p_firmware *
siemens ek-ertec_200p_firmware 4.6
siemens ek-ertec_200p -
siemens simatic_cfu_pa_firmware *
siemens simatic_cfu_pa -
siemens simatic_et_200al_firmware *
siemens simatic_et_200al -
siemens simatic_et_200m_firmware *
siemens simatic_et_200m -
siemens simatic_et_200mp_im_155-5_pn_ba_firmware *
siemens simatic_et_200mp_im_155-5_pn_ba -
siemens simatic_et_200mp_im_155-5_pn_hf_firmware *
siemens simatic_et_200mp_im_155-5_pn_hf -
siemens simatic_et_200mp_im_155-5_pn_st_firmware *
siemens simatic_et_200mp_im_155-5_pn_st -
siemens simatic_et_200s_firmware *
siemens simatic_et_200s -
siemens simatic_et_200sp_im_155-6_pn_ba_firmware *
siemens simatic_et_200sp_im_155-6_pn_ba -
siemens simatic_et_200sp_im_155-6_pn_ha_firmware *
siemens simatic_et_200sp_im_155-6_pn_ha -
siemens simatic_et_200sp_im_155-6_pn_hf_firmware *
siemens simatic_et_200sp_im_155-6_pn_hf -
siemens simatic_et_200sp_im_155-6_pn_hs_firmware *
siemens simatic_et_200sp_im_155-6_pn_hs -
siemens simatic_et_200sp_im_155-6_pn_st_firmware *
siemens simatic_et_200sp_im_155-6_pn_st -
siemens simatic_et_200sp_im_155-6_pn\/2_hf_firmware *
siemens simatic_et_200sp_im_155-6_pn\/2_hf -
siemens simatic_et_200sp_im_155-6_pn\/3_hf_firmware *
siemens simatic_et_200sp_im_155-6_pn\/3_hf -
siemens simatic_et_200ecopn_firmware *
siemens simatic_et_200ecopn -
siemens simatic_et_200pro_firmware *
siemens simatic_et_200pro -
siemens simatic_hmi_comfort_outdoor_panels_7\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_7\" -
siemens simatic_hmi_comfort_outdoor_panels_15\"_firmware *
siemens simatic_hmi_comfort_outdoor_panels_15\" -
siemens simatic_hmi_comfort_panels_4\"_firmware *
siemens simatic_hmi_comfort_panels_4\" -
siemens simatic_hmi_comfort_panels_22\"_firmware *
siemens simatic_hmi_comfort_panels_22\" -
siemens simatic_hmi_ktp_mobile_panels_firmware *
siemens simatic_hmi_ktp_mobile_panels -
siemens simatic_pn\/pn_coupler_firmware *
siemens simatic_pn\/pn_coupler -
siemens simatic_profinet_driver_firmware *
siemens simatic_profinet_driver -
siemens simatic_s7-1200_cpu_firmware *
siemens simatic_s7-1200_cpu -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1500_cpu_firmware *
siemens simatic_s7-1500_cpu -
siemens simatic_s7-1500s_cpu_firmware *
siemens simatic_s7-1500s_cpu -
siemens simatic_s7-1500t_cpu_firmware *
siemens simatic_s7-1500t_cpu -
siemens simatic_s7-1500_cpu_1518_firmware *
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1511c_firmware *
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1512c_firmware *
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-300_cpu_firmware *
siemens simatic_s7-300_cpu -
siemens simatic_s7-300_cpu_312_ifm_firmware *
siemens simatic_s7-300_cpu_312_ifm -
siemens simatic_s7-300_cpu_313_firmware *
siemens simatic_s7-300_cpu_313 -
siemens simatic_s7-300_cpu_314_firmware *
siemens simatic_s7-300_cpu_314 -
siemens simatic_s7-300_cpu_314_ifm_firmware *
siemens simatic_s7-300_cpu_314_ifm -
siemens simatic_s7-300_cpu_315_firmware *
siemens simatic_s7-300_cpu_315 -
siemens simatic_s7-300_cpu_315-2_dp_firmware *
siemens simatic_s7-300_cpu_315-2_dp -
siemens simatic_s7-300_cpu_316-2_dp_firmware *
siemens simatic_s7-300_cpu_316-2_dp -
siemens simatic_s7-300_cpu_318-2_firmware *
siemens simatic_s7-300_cpu_318-2 -
siemens simatic_s7-400_pn_v7_firmware *
siemens simatic_s7-400_pn_v7 -
siemens simatic_s7-400_dp_v7_firmware *
siemens simatic_s7-400_dp_v7 -
siemens simatic_s7-400_v6_firmware *
siemens simatic_s7-400_v6 -
siemens simatic_s7-400h_v6_firmware *
siemens simatic_s7-400h_v6 -
siemens simatic_s7-410_v8_firmware *
siemens simatic_s7-410_v8 -
siemens simatic_winac_rtx_\(f\)_firmware *
siemens simatic_winac_rtx_\(f\)_firmware 2010
siemens simatic_winac_rtx_\(f\)_2010 -
siemens sinamics_dcm_firmware *
siemens sinamics_dcm_firmware 1.5
siemens sinamics_dcm -
siemens sinamics_dcp_firmware *
siemens sinamics_dcp -
siemens sinamics_g110m_firmware *
siemens sinamics_g110m_firmware 4.7
siemens sinamics_g110m -
siemens sinamics_g120_firmware *
siemens sinamics_g120_firmware 4.7
siemens sinamics_g120 -
siemens sinamics_g130_firmware *
siemens sinamics_g130_firmware 5.2
siemens sinamics_g130 -
siemens sinamics_g150_firmware *
siemens sinamics_g150_firmware 5.2
siemens sinamics_g150 -
siemens sinamics_gl150_firmware *
siemens sinamics_gl150_firmware 4.8
siemens sinamics_gl150 -
siemens sinamics_gm150_firmware *
siemens sinamics_gm150_firmware 4.8
siemens sinamics_gm150 -
siemens sinamics_s110_firmware *
siemens sinamics_s110 -
siemens sinamics_s120_firmware *
siemens sinamics_s120_firmware 5.2
siemens sinamics_s120 -
siemens sinamics_s150_firmware *
siemens sinamics_s150_firmware 5.2
siemens sinamics_s150 -
siemens sinamics_sl150_firmware *
siemens sinamics_sl150_firmware 4.7
siemens sinamics_sl150 -
siemens sinamics_sm120_firmware -
siemens sinamics_sm120 -
siemens sinumerik_828d *
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_828d 4.8
siemens sinumerik_840d_sl *



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E19343EA-5ECA-4263-A568-DAEA04425F86",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "53DF35F1-94FF-4D0B-9FA2-E8B0AFAEA5FF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "70D5CDF4-A134-402E-A4E9-4BBA19082397",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B47CF3BB-08E4-4B86-B793-8253C172D846",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2773F4B7-095E-4A33-93F2-765FA58B828C",
              "versionEndExcluding": "4.6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:ek-ertec_200p_firmware:4.6:-:*:*:*:*:*:*",
              "matchCriteriaId": "9E7753EE-DF23-4838-B3B4-7C43C550519C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:ek-ertec_200p:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB75CD44-5223-40A7-A835-111BF3C25D23",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABA8C0E5-E6AA-4BF2-925F-0041C382A416",
              "versionEndExcluding": "1.2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6C1E4CC-2657-4383-83D8-5C8F88B12755",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E01824-4942-4400-A8C2-43A5772C2968",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34C17B00-34B5-4A15-9333-252BE2975F37",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14E56570-5C20-40BD-BF0B-F6ED06AFC8F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7037E46B-4FE5-4693-B6A6-B5AF7B652C4F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B4458E08-9864-452E-B95E-A46C5600D488",
              "versionEndExcluding": "4.3.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9AF349D2-2560-4C60-8729-4B6CCDC52347",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "00743200-D240-4CBC-8652-555F5E89B042",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AB9BFB03-D366-4F23-9477-D6133BD021CF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200mp_im_155-5_pn_st_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "ACDF9AF3-DDB9-41A8-90C5-2A95A51D5EDE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200mp_im_155-5_pn_st:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B48C0A4-072A-4744-94A5-FC4741F4A029",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB063929-AAB0-4FF8-BCA3-71BA80517B1A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1EC40E7-F004-446C-B5C9-0AB9911105E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ba_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8A1327FC-E785-4AA7-BC73-CC61CEED832D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ba:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C0300D2-1A87-4F61-9444-C1D23E3E6033",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_ha_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17B7ED41-6AC7-4D34-A94E-61AECFA088EA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_ha:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "34131306-1591-42B3-B235-4265F918CBDA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "67DAE64A-6E78-452E-9812-242769378ED8",
              "versionEndExcluding": "4.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "527AE806-5C00-4C44-940F-88032AD8120D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_hs_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAAA8667-C792-45E4-AE5E-C194B5B76366",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_hs:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "455EC7E5-236B-43E6-86E7-702FAFCCCB15",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn_st_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "918CBE10-D912-446B-B8B3-843B0089CB7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn_st:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DB6FAE7-8598-4673-83A9-7A838BB207C5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6269D1CC-FF57-409F-8284-C95FF4DCEF25",
              "versionEndExcluding": "4.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/2_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CBAACFE-CD21-4FAC-9262-1A7F325D6E40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3FA7253F-17B9-411B-B4C9-FE51DF0DE44D",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200sp_im_155-6_pn\\/3_hf:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCCAFEF7-CA0C-4F20-B98E-DBB8365F1CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EE0B998-E408-408F-8F78-5E90F74E9C9B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0259EAE9-0CA0-49A5-A573-8339604A181B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D054139B-BE36-4B34-88AE-BC487DCB1DCB",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0CE2EC-9A73-4576-A389-A19893D47B0F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5F14E991-8DF6-4221-A9BF-E13EEF211220",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CE84D161-BA23-422A-8959-CF047834A631",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6230347-9AAE-424F-A46F-4A714BA0823D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1A44BC-15CC-4CC1-A9D0-4B04233B80CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "54EFA8B5-8DA1-4547-9E15-BDC265C56006",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_pn\\/pn_coupler_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "87B14F05-4D54-420F-8393-4AB27EF6A7D1",
              "versionEndExcluding": "4.2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "49FB85F8-7D45-433E-805B-360725F2980C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_profinet_driver_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "05248152-94EB-4978-98A7-B1A393CA1F03",
              "versionEndExcluding": "2.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "526493E9-EF74-4836-9A8F-134B625035AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2BA63AED-84E4-4F92-A4D4-0713E7F65C4A",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2B63726-10CE-46AB-ADBA-A511E770E162",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D81B519-6FE9-405C-8BB1-57D14AF531E5",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84E0444D-01E0-4F7A-81A0-314C0F7FA623",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B980BB8C-9AFE-45E4-A4D4-AB555B234059",
              "versionEndExcluding": "4.4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BD6FB801-AE4C-4EDF-96CC-33A4CD51165A",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "01048F7F-9C5B-47C0-AE16-321FCA670F3D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500s_cpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D5DE5B3D-13B1-4684-8859-C3FB34FE50CF",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500s_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B82EADBC-AECE-45B4-AF95-6F0D84966E67",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500t_cpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF5E4914-A5EA-451C-9FAF-751B74B8BC69",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500t_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BE2F683-2A24-4152-9A07-00B0117C5F12",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B6777DC-80B5-4B36-B9AA-DA764C8016F7",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "55490E3D-616D-4D21-BAC2-29A51CB067E9",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "45303F50-046B-4621-AC6D-2B6E17D948C3",
              "versionEndExcluding": "2.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C87674A8-B518-4910-B03D-FFF4D5A7B627",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_312_ifm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B0C6327-7BF6-4B96-82A8-D750007869EE",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312_ifm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCFCAA2B-71FE-4DB4-B8B0-F5FD1254C331",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_313_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3EF9F3FB-FBBA-42A8-9A90-FE34703274B5",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_313:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4E6E900F-63C1-4E50-9DCD-26CE760E5275",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8F2F0659-CD37-4AA9-B7D5-44639515533C",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_ifm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "07AD63B6-B05C-4BBF-812D-379C4D8F8CC7",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314_ifm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "8BE7963C-7AFF-495B-9F0B-28FB393443FD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7F2A0C75-E360-4E3D-85DA-878E39054E26",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E3962681-E32E-4BD1-8C71-8768248691D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "488F0774-43DA-455D-905C-C514A0192260",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_316-2_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F103C351-99C9-4F7D-B69A-D8A876F57504",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_316-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "644AD6A8-AEDE-4F1C-92F8-836877A81310",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_318-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BA99549B-5E95-445A-A95B-1CDA7014686B",
              "versionEndExcluding": "3.3.17",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_318-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF58C652-E74D-4B57-A7C5-08D7446863D5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_pn_v7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B6B9D8B-D7BA-4D72-97C7-7BBEB49802F7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_pn_v7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E4F8215E-E737-4CD5-B7D9-57FE4A2A2FE5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_dp_v7_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "72F7B870-35A1-4900-8104-1303F291E29A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_dp_v7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9F7D2-22C7-4E7C-99C3-4A88CDD2CDB7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400_v6_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A4C79A5-96BB-4ADB-B28A-C9C48B195F49",
              "versionEndExcluding": "6.0.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400_v6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6445275-2AEF-4285-BE7A-67F20182481C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EE93A33C-7007-4908-868A-4FBE4D073E57",
              "versionEndExcluding": "6.0.9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1D082EB6-3C13-40C1-9949-179DC59037C1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "63EA1886-A72E-48A7-B99F-C236BF6992FA",
              "versionEndExcluding": "8.2.2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "926D9DCF-A7EA-416A-9A07-122D1FCA027B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D03BD73-51ED-42E0-A552-C32BB7A935B2",
              "versionEndExcluding": "2010",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:simatic_winac_rtx_\\(f\\)_firmware:2010:-:*:*:*:*:*:*",
              "matchCriteriaId": "7151A19C-0AE5-4F66-9E3D-8BF675A8430C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E6034789-ABD1-4035-8378-F0BA7157B087",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "84B1F9B1-4248-4A4C-A8BB-77475A0E9B9B",
              "versionEndExcluding": "1.5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcm_firmware:1.5:-:*:*:*:*:*:*",
              "matchCriteriaId": "F2F99FFB-C312-4080-9580-84AFB7C9FA09",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A1A43D34-ECA3-4330-B85F-02BDD1D22149",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83803F1C-4842-43BB-B903-C2E91FF7DC08",
              "versionEndExcluding": "1.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B75F50CA-7371-4BC7-8D8A-13F8BC69E4EB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "775C90BB-C026-435C-889A-517EF85656C5",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "CAA92AC6-7DA0-418D-A13F-69268DFD7966",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D61D3E9C-1346-4354-BCD9-B02F67500C41",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B1DBCA1A-27F3-4E9A-9F89-65E82A68DE4A",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g120_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "94CB2F3E-AAA1-4472-BFD4-4E6E1B663FF5",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61A60DCE-384B-43A4-A669-973FB8ECA932",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "856768D2-C096-4CA7-B26F-E94B005C0D79",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g130_firmware:5.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "AD0515D7-829B-4591-95D9-94C3982FD727",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "373DBE44-AC28-4D04-93BB-35CD8C60E899",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C579C2C7-0402-46B2-A770-C3B7F71D1096",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_g150_firmware:5.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "255A153A-A6A0-46A4-A7CF-01D0D09761C7",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2296CA65-0E89-4BCB-8003-E7212BF1F585",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3653DA37-DB23-41E0-8CE8-838E384AA40A",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "0F86A334-10F9-4DFB-A421-CBCAFD86C8C2",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0E25804D-D943-4C2A-9C78-AAC61F7BA4FF",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "06B69CD4-3AEC-4014-81DB-33805A44A5D3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s110_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "243FFEA3-7193-45EA-B865-E9CA1D6656FE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6218802E-D3B1-4197-A6B5-7343A50F7D88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03F9CBC3-B2B3-4FA7-963D-A8F3AE6D8EA0",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s120_firmware:5.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "6622AE2E-81B0-419C-8C37-A7C56FB92745",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5A824BD-935F-4E53-8313-C5544B0489C7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BF989EE-CD8D-450D-90F6-FD15F00B59B9",
              "versionEndExcluding": "5.2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_s150_firmware:5.2:-:*:*:*:*:*:*",
              "matchCriteriaId": "EFFDE2CB-684D-4ECE-A104-F355254A46B9",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D48682C-A39D-4A09-B904-50FA64A9D2A5",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30E52510-9306-42B8-A517-A6BBD34B8B9D",
              "versionEndExcluding": "4.7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:4.7:-:*:*:*:*:*:*",
              "matchCriteriaId": "58A71910-E54F-426B-BAB1-260AEFD8EF6E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "28DB0BC6-E60A-4798-80DC-125EF25B3A40",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "328F0192-B34D-481C-8964-226317439966",
              "versionEndExcluding": "4.8",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:-:*:*:*:*:*:*",
              "matchCriteriaId": "C7936CF6-DC07-4550-9FEC-823A2F49096D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "BEE7D914-F2DE-4D8C-BFB2-7AD16650CD3F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "BDBAEDBC-6A76-495D-9BC7-BA687F32EE40",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "45EF769B-1EB1-4D2D-84C5-8005EF1EE1EF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_828d:4.8:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "48EE5859-5450-4078-94E7-E525B999A837",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:sinumerik_840d_sl:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9FFC86D6-F312-4097-91A6-79C78502323F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Kits de desarrollo/evaluaci\u00f3n para PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS), SIMATIC ET200AL, SIMATIC ET200M (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incl. variantes SIPLUS) SIPLUS), SIMATIC ET200S (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incl. variantes SIPLUS). SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, paneles exteriores SIMATIC HMI Comfort de 7\" y 15\" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4\" a 22\" (incl. variantes SIPLUS), paneles m\u00f3viles SIMATIC HMI KTP, acoplador SIMATIC PN/PN (incl. variantes SIPLUS NET), driver SIMATIC PROFINET, familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-1500 (incl. variantes SIPLUS). CPUs ET200 y variantes SIPLUS), SIMATIC S7-1500 Software Controller, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS). SIPLUS), familia de CPU SIMATIC S7-410 V8 (incl. variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SINAMICS DCM, SINAMICS DCP, SINAMICS G110M V4. 7 PN Control Unit, SINAMICS G120 V4.7 PN Control Unit (incl. variantes SIPLUS), SINAMICS G130 V4.7 Control Unit, SINAMICS G150 Control Unit, SINAMICS GH150 V4. 7, SINAMICS GL150 V4.7, SINAMICS GM150 V4.7, SINAMICS S110, SINAMICS S120 V4.7 (incluidas las variantes SIPLUS), SINAMICS S150, SINAMICS SL150 V4.7, SINAMICS SM120 V4.7, SINUMERIK 828D, SINUMERIK 840D sl. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autenticado desencadenar una condici\u00f3n de denegaci\u00f3n de servicio. La vulnerabilidad puede activarse si se env\u00eda al dispositivo una gran cantidad de paquetes UDP especialmente dise\u00f1ados. La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso a la red de los sistemas afectados. La explotaci\u00f3n exitosa no requiere privilegios del sistema ni interacci\u00f3n del usuario. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la disponibilidad del dispositivo. En el momento de la publicaci\u00f3n del aviso no se conoc\u00eda ninguna explotaci\u00f3n p\u00fablica de esta vulnerabilidad de seguridad"
    }
  ],
  "id": "CVE-2019-10936",
  "lastModified": "2024-11-21T04:20:11.257",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.0,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2019-10-10T14:15:14.707",
  "references": [
    {
      "source": "productcert@siemens.com",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
    },
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-400"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2022-12-13 16:15
Modified
2024-11-21 06:23
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
siemens simatic_s7-plcsim_advanced_firmware *
siemens simatic_s7-plcsim_advanced -
siemens simatic_s7-1200_cpu_1211c_firmware *
siemens simatic_s7-1200_cpu_1211c -
siemens simatic_s7-1200_cpu_1212c_firmware *
siemens simatic_s7-1200_cpu_1212c -
siemens simatic_s7-1200_cpu_1212fc_firmware *
siemens simatic_s7-1200_cpu_1212fc -
siemens simatic_s7-1200_cpu_1214_fc_firmware *
siemens simatic_s7-1200_cpu_1214_fc -
siemens simatic_s7-1200_cpu_1214c_firmware *
siemens simatic_s7-1200_cpu_1214c -
siemens simatic_s7-1200_cpu_1214fc_firmware *
siemens simatic_s7-1200_cpu_1214fc -
siemens simatic_s7-1200_cpu_1215_fc_firmware *
siemens simatic_s7-1200_cpu_1215_fc -
siemens simatic_s7-1200_cpu_1215c_firmware *
siemens simatic_s7-1200_cpu_1215c -
siemens simatic_s7-1200_cpu_1215fc_firmware *
siemens simatic_s7-1200_cpu_1215fc -
siemens simatic_s7-1200_cpu_1217c_firmware *
siemens simatic_s7-1200_cpu_1217c -
siemens simatic_s7-1200_cpu_12_1211c_firmware *
siemens simatic_s7-1200_cpu_12_1211c -
siemens simatic_s7-1200_cpu_12_1212c_firmware *
siemens simatic_s7-1200_cpu_12_1212c -
siemens simatic_s7-1200_cpu_12_1212fc_firmware *
siemens simatic_s7-1200_cpu_12_1212fc -
siemens simatic_s7-1200_cpu_12_1214c_firmware *
siemens simatic_s7-1200_cpu_12_1214c -
siemens simatic_s7-1200_cpu_12_1214fc_firmware *
siemens simatic_s7-1200_cpu_12_1214fc -
siemens simatic_s7-1200_cpu_12_1215c_firmware *
siemens simatic_s7-1200_cpu_12_1215c -
siemens simatic_s7-1200_cpu_12_1215fc_firmware *
siemens simatic_s7-1200_cpu_12_1215fc -
siemens simatic_s7-1200_cpu_12_1217c_firmware *
siemens simatic_s7-1200_cpu_12_1217c -
siemens siplus_s7-1200_cp_1243-1_rail_firmware *
siemens siplus_s7-1200_cp_1243-1_rail -
siemens siplus_s7-1200_cp_1243-1_firmware *
siemens siplus_s7-1200_cp_1243-1 -
siemens simatic_s7-1500_cpu_1507s_firmware *
siemens simatic_s7-1500_cpu_1507s -
siemens simatic_s7-1500_cpu_1507s_f_firmware *
siemens simatic_s7-1500_cpu_1507s_f -
siemens simatic_s7-1500_cpu_1508s_firmware *
siemens simatic_s7-1500_cpu_1508s -
siemens simatic_s7-1500_cpu_1508s_f_firmware *
siemens simatic_s7-1500_cpu_1508s_f -
siemens simatic_s7-1500_cpu_1510sp_firmware *
siemens simatic_s7-1500_cpu_1510sp -
siemens simatic_s7-1500_cpu_1510sp-1_firmware *
siemens simatic_s7-1500_cpu_1510sp-1 -
siemens simatic_s7-1500_cpu_1511-1_firmware *
siemens simatic_s7-1500_cpu_1511-1 -
siemens simatic_s7-1500_cpu_1511-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511-1_pn -
siemens simatic_s7-1500_cpu_1511c_firmware *
siemens simatic_s7-1500_cpu_1511c -
siemens simatic_s7-1500_cpu_1511c-1_firmware *
siemens simatic_s7-1500_cpu_1511c-1 -
siemens simatic_s7-1500_cpu_1511f-1_firmware *
siemens simatic_s7-1500_cpu_1511f-1 -
siemens simatic_s7-1500_cpu_1511f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1511f-1_pn -
siemens simatic_s7-1500_cpu_1511t-1_firmware *
siemens simatic_s7-1500_cpu_1511t-1 -
siemens simatic_s7-1500_cpu_1511tf-1_firmware *
siemens simatic_s7-1500_cpu_1511tf-1 -
siemens simatic_s7-1500_cpu_1512c_firmware *
siemens simatic_s7-1500_cpu_1512c -
siemens simatic_s7-1500_cpu_1512c-1_firmware *
siemens simatic_s7-1500_cpu_1512c-1 -
siemens simatic_s7-1500_cpu_1512sp-1_firmware *
siemens simatic_s7-1500_cpu_1512sp-1 -
siemens simatic_s7-1500_cpu_1512spf-1_firmware *
siemens simatic_s7-1500_cpu_1512spf-1 -
siemens simatic_s7-1500_cpu_1513-1_firmware *
siemens simatic_s7-1500_cpu_1513-1 -
siemens simatic_s7-1500_cpu_1513-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513-1_pn -
siemens simatic_s7-1500_cpu_1513f-1_firmware *
siemens simatic_s7-1500_cpu_1513f-1 -
siemens simatic_s7-1500_cpu_1513f-1_pn_firmware *
siemens simatic_s7-1500_cpu_1513f-1_pn -
siemens simatic_s7-1500_cpu_1513r-1_firmware *
siemens simatic_s7-1500_cpu_1513r-1 -
siemens simatic_s7-1500_cpu_1515-2_firmware *
siemens simatic_s7-1500_cpu_1515-2 -
siemens simatic_s7-1500_cpu_1515-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515-2_pn -
siemens simatic_s7-1500_cpu_151511c-1_firmware *
siemens simatic_s7-1500_cpu_151511c-1 -
siemens simatic_s7-1500_cpu_151511f-1_firmware *
siemens simatic_s7-1500_cpu_151511f-1 -
siemens simatic_s7-1500_cpu_1515f-2_firmware *
siemens simatic_s7-1500_cpu_1515f-2 -
siemens simatic_s7-1500_cpu_1515f-2_pn_firmware *
siemens simatic_s7-1500_cpu_1515f-2_pn -
siemens simatic_s7-1500_cpu_1515r-2_firmware *
siemens simatic_s7-1500_cpu_1515r-2 -
siemens simatic_s7-1500_cpu_1515t-2_firmware *
siemens simatic_s7-1500_cpu_1515t-2 -
siemens simatic_s7-1500_cpu_1515tf-2_firmware *
siemens simatic_s7-1500_cpu_1515tf-2 -
siemens simatic_s7-1500_cpu_1516-3_firmware *
siemens simatic_s7-1500_cpu_1516-3 -
siemens simatic_s7-1500_cpu_1516-3_dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_dp -
siemens simatic_s7-1500_cpu_1516-3_pn_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn -
siemens simatic_s7-1500_cpu_1516-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516f-3_firmware *
siemens simatic_s7-1500_cpu_1516f-3 -
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1516f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1516pro-2_firmware *
siemens simatic_s7-1500_cpu_1516pro-2 -
siemens simatic_s7-1500_cpu_1516pro_f_firmware *
siemens simatic_s7-1500_cpu_1516pro_f -
siemens simatic_s7-1500_cpu_1516t-3_firmware *
siemens simatic_s7-1500_cpu_1516t-3 -
siemens simatic_s7-1500_cpu_1516tf-3_firmware *
siemens simatic_s7-1500_cpu_1516tf-3 -
siemens simatic_s7-1500_cpu_1517-3_firmware *
siemens simatic_s7-1500_cpu_1517-3 -
siemens simatic_s7-1500_cpu_1517-3_dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_dp -
siemens simatic_s7-1500_cpu_1517-3_pn_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn -
siemens simatic_s7-1500_cpu_1517-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517f-3_firmware *
siemens simatic_s7-1500_cpu_1517f-3 -
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1517f-3_pn\/dp -
siemens simatic_s7-1500_cpu_1517tf-3_firmware *
siemens simatic_s7-1500_cpu_1517tf-3 -
siemens simatic_s7-1500_cpu_1518_firmware *
siemens simatic_s7-1500_cpu_1518 -
siemens simatic_s7-1500_cpu_1518-4_firmware *
siemens simatic_s7-1500_cpu_1518-4 -
siemens simatic_s7-1500_cpu_1518-4_dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_dp -
siemens simatic_s7-1500_cpu_1518-4_pn_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp_firmware *
siemens simatic_s7-1500_cpu_1518-4_pn\/dp_mfp -
siemens simatic_s7-1500_cpu_1518f-4_firmware *
siemens simatic_s7-1500_cpu_1518f-4 -
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp_firmware *
siemens simatic_s7-1500_cpu_1518f-4_pn\/dp -
siemens simatic_s7-1500_cpu_1518hf-4_firmware *
siemens simatic_s7-1500_cpu_1518hf-4 -
siemens simatic_s7-1500_cpu_1518t-4_firmware *
siemens simatic_s7-1500_cpu_1518t-4 -
siemens simatic_s7-1500_cpu_1518tf-4_firmware *
siemens simatic_s7-1500_cpu_1518tf-4 -
siemens simatic_s7-1500_cpu_15pro-2_firmware *
siemens simatic_s7-1500_cpu_15pro-2 -
siemens simatic_s7-1500_cpu_15prof-2_firmware *
siemens simatic_s7-1500_cpu_15prof-2 -
siemens simatic_s7-1500_cpu_cpu_1513pro-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513pro-2 -
siemens simatic_s7-1500_cpu_cpu_1513prof-2_firmware *
siemens simatic_s7-1500_cpu_cpu_1513prof-2 -
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware *
siemens siplus_et_200sp_cp_1542sp-1_irc_tx_rail -
siemens siplus_et_200sp_cp_1543sp-1_isec_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec -
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware *
siemens siplus_et_200sp_cp_1543sp-1_isec_tx_rail -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware -
siemens simatic_et_200_sp_open_controller_cpu_1515sp_pc -
siemens simatic_s7-1500_software_controller_firmware -
siemens simatic_s7-1500_software_controller -
siemens siplus_s7-300_cpu_314_firmware -
siemens siplus_s7-300_cpu_314 -
siemens siplus_s7-300_cpu_315-2_dp_firmware -
siemens siplus_s7-300_cpu_315-2_dp -
siemens siplus_s7-300_cpu_315-2_pn\/dp_firmware -
siemens siplus_s7-300_cpu_315-2_pn\/dp -
siemens siplus_s7-300_cpu_317-2_pn\/dp_firmware -
siemens siplus_s7-300_cpu_317-2_pn\/dp v6
siemens siplus_tim_1531_irc_firmware -
siemens siplus_tim_1531_irc -
siemens tim_1531_irc_firmware -
siemens tim_1531_irc -



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-plcsim_advanced_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C9A0C34-9116-4835-8372-C72273B9CE08",
              "versionEndExcluding": "5.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-plcsim_advanced:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "531A509E-97C9-4838-9E12-7D12DA36616F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3C6CC47-5B8D-4FF7-B836-AB2C5C5D4189",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "30B06ABC-30A2-4E3D-9A3C-E3B70308B427",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0AE09A9F-1EA2-4390-9648-61B2318EA930",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B64D841-42F1-4942-8568-A4E3B64A9711",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CDF6B5E8-3B42-4E79-82CD-54112C819C0E",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E57A3D6-F939-49CB-85ED-319A9A447FF6",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE46D66-A6B6-4554-8642-7F3E7E3AA22D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D13B9DEC-0DC1-4F4B-9CD8-B0C4849EE0A7",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3BB3B1-5501-4044-9B10-64C7865E0B69",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E54F1417-426E-45B2-AACA-D3A4EEDA162D",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4866FF7B-B34A-4828-94A8-BD0A0B6F4C88",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6A37E51-044D-4420-98C5-FCE1C9FA0B77",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7FC3792E-C935-4AE9-B07F-C32F10072861",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F3984C91-A38D-4498-9505-4C7894502617",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "510EB4BE-7425-48C9-A3AB-B7932CFBCBC4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F6708491-A3CD-4100-BF43-74FB421E7B03",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1452445-A671-463B-B175-07122B0D0F0A",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E75190A-198B-4A8D-9E16-27665A4168D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9B89FB6F-4635-49B4-AF9C-17882F1D79E4",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AAD6D800-87DE-4C8A-B60B-C5AD196D5F54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1214fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "8722D9A2-C1AE-4B19-8827-A0BAE35BCEBC",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1214fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D89586C8-CD63-457B-8685-5C50D0592D64",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3D74CF17-23D8-4F5F-8387-F9F751DFC37C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38719F3-6D7A-4200-9146-5C4AFABEB787",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1215fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "689A662A-4CB4-40B6-946F-9ED223C929C8",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1215fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0155A47-734B-4C2C-8A8A-D6B88507DFB3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_12_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "75D64AC3-E8AD-4906-836E-C6C0C77FDD7F",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_12_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DE62DBA-6865-4D1B-8651-90056C089909",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFB7D20A-C951-467B-902F-C5B61AEE8722",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A294530-727C-4535-8B02-668DF74587D4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-1200_cp_1243-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92D26AE4-A61C-4DDE-AC0E-7ADA6C16168C",
              "versionEndExcluding": "4.6.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-1200_cp_1243-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F9E746CF-4009-4A14-8916-A9E0276CAF8B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "37574513-3CE7-4A82-A495-272FDD01FADE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "39C1392C-38E2-4AF9-AF17-91B93BC6B9B8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1507s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF3A272D-45A1-4195-9B11-65D6BAACC425",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1507s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F1ED29DF-8AC0-4BB6-ACE2-EBC0A2B87F96",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C48F5FEA-357C-4630-940F-06C7D175B8F2",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "46CBD063-6CF0-45E6-A9D1-C7F8709806AA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1508s_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5C73EC1A-3099-4099-AC21-2B5BA82B428E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1508s_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A2079B95-E885-4490-BCEA-62BBEAF9CB51",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "85AECB2F-8AEC-4503-B45B-E32F6B081481",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D7ECCF7-E3EE-46A0-BC03-51AAEBCD03EE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1510sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1A94DA11-E1EC-4792-8D08-D96C24EA60A7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1510sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "38232B80-9EDE-4BE4-BD4C-0E84B18EC39A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D1858266-384F-415E-AC75-9082729E80C0",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D8B9B76B-D790-44B9-AC2A-7E0719C4D56C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FAD92A57-8592-4594-BAFE-BE50B9421EEA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F62F4050-F6C9-4C8F-8E09-F0AEEDB6B1FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "28DAE724-8A2A-42EB-A407-FE3CC5E11303",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "822894D4-96D5-4BDC-A698-D31262BCF422",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2923D75B-ACF8-47FF-859D-5F780CBF8A2B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F580D0D-F406-4586-9C54-EF44703FDA30",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "79A2DD7B-FE32-4873-9689-64B34BD7A871",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6B51EFC-2168-4B28-9527-A8DC62781709",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "17C0E003-6B46-4D32-9EF2-7EEC1E625534",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3A3E8A67-2A29-4DE9-AF1B-D74A42D55D1E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511t-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "41E677CA-74B5-4281-816F-13B754EAEC85",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511t-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DBA72709-BC38-425F-8EBD-FE16C5A86140",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1511tf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E60CDAF9-C304-4895-B60B-7BCE87B6AF62",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1511tf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6E76D7BD-0529-4A51-9866-8AF5241A5184",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B209AD7-8F7D-4D8D-9C0E-ADBBBDF0D2D1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2E24A4C-AC13-4382-BDF6-E13878FED4DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "58B467A4-41F0-4CA3-9BE4-B5DBBE0B75A4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7933577-8564-4DE4-AAED-62F87E3C3353",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512sp-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "62A4DD30-1982-4126-8D18-9E9A18B88E52",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512sp-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A0E822C9-6983-4CC6-BC51-822563DF7BCE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1512spf-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "03CB600B-A8BD-4C13-940F-A7E22C732129",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1512spf-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "77BD8110-76B4-4D5C-BFF7-E5F1D0EA9CD6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F08F8454-11F2-4903-8845-17BA53092E99",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2E7889F5-D499-41A6-B1BB-264F988884D8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1E8AD64D-AE4E-4E56-B64D-80C3FEB50839",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6663D66-5127-4F5D-B39D-50D3F88F4435",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA9AF054-5D96-4C5D-87BA-73949C4D3BA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2962FF0-D865-4D15-B1A7-EFC0501972A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513f-1_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F18A96A0-C9C2-4F86-911A-FBEAB37D774E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513f-1_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "69DE61DE-5B71-4F35-AC4F-C6EC24A7DDAA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1513r-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A23DFA83-45DC-4FEE-9291-4B35487B2BEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1513r-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E2F34DF-3A55-49A4-9A9C-80C99B367079",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "966ACB66-7F82-4784-9969-63F4B82385F7",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EB7605AF-2B00-49DD-BC32-37E6CF9ED625",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "726B3940-F85B-4760-8C07-56C9B7EE6221",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE9C79B-52A3-45F4-9DA5-6D61A6BF7753",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511c-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C972215A-F45D-4730-80C9-72874221408C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511c-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA60D4EE-EB60-4B06-B48A-0859999F9F83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_151511f-1_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6AD40846-918D-4970-8FDC-4368CCD730D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_151511f-1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "448DD8BF-6DE3-4B05-A396-6EB1C4FE7968",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5837F598-317F-48CE-AC05-2832F68DB71B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "21A4E04A-EB99-4AB2-9B30-C70DB11A6C8D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515f-2_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0B146AC-0BF0-42EF-9818-FEE8BC98197B",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515f-2_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EDE82551-008D-4B75-BDB5-3DD30ADD1863",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515r-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "60DEC18D-5A11-4CC4-9169-31130418A5E4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515r-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA0AEBFA-682F-4F5D-8FAA-D517AE3B3D0C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515t-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F89A4C42-7FC8-48B0-AC56-D5E5DC3771EF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515t-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7BC3993-1CB0-4C1D-BC04-ED69BA814B24",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1515tf-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1B00477-3871-4B60-94E2-93FDCAF2C921",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1515tf-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "89839624-6FA1-4377-A3B4-9CB704555E2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5983C923-9D2F-4888-8C7F-1F7C40F45B69",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B6D611B2-4D81-4838-B612-8D17196A5B78",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DE7EAEC5-1B73-4A47-81F8-18ADDF5E66A8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5FD1F20-E507-4422-814D-19614CDB49B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4BA8F18C-446C-4795-B9EB-2213336F8DEE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "439E1B3E-7174-4BAC-A11A-F4F37ABB7291",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1B256C1-7476-437C-935F-B44E27589F37",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A5C12961-CCF4-4248-9E43-8866671A257A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1C9E1DB6-0613-479E-8215-7C8ED8736321",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "44C84DC4-1E8C-431B-AF23-AA86CE316928",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E06F09B1-5A87-4232-B604-A51445FF707E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5787D689-D80C-47BC-A0C2-E45E0FAD49D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F909702-CAD9-40F9-8CD0-1EAFB49EB108",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AD3A239E-41CB-4222-8146-745B15C206C3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516pro_f_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5A41226-5658-4871-9DA9-70802E0A939E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516pro_f:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "298EF297-949E-45E9-9A57-8D07986DED10",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516t-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6BEF75D1-E68E-42F3-9A15-D31116854212",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516t-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27653C38-64A3-4DE2-8B65-BBC356A396AE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1516tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "382C22D4-DB54-4AC9-9F31-0386264BE4DF",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1516tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A66C6524-9076-4C4E-B518-586BB1FF7107",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "83F5D1D3-2452-47F8-85D6-24EF159342DA",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C03BFBC2-E30D-4DAF-BDE0-06F97D1A0E92",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2D2DBE49-F5ED-46DC-B7B7-61C4624BD8D6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "ABE53C35-490A-498B-8CAB-B874C0E17AF1",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0A6E4A98-5656-4CCD-B41E-0413D1E0584D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4C44E126-E4D9-44D8-B8B9-10F060D63A2B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2281F79-9098-4FEC-8303-3C426870BEE8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "984F6E53-482D-4282-BBAA-87B0375310FA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCD72B5F-10B0-4CF6-8498-8431384CDBA6",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F4C4030-4BFE-4EA0-9967-F77EEB5113E0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CA937CE7-4E65-45BA-8750-3498D3A4F4F4",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517f-3_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB2327DF-ADA4-453E-A35E-E986D822F1E7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1517tf-3_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "815E4D53-C0F4-4DE8-A9F9-998838D4E300",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1517tf-3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E1BD045A-0DC6-4D6F-A596-B24ECA84936B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "66F5A4A6-D7F8-492C-A254-84F3EF3BDF1D",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BE0BA68C-EB57-49CE-94A8-E7905AB79824",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F8C580F7-A436-4CDA-B273-A60EF5E7552C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "836BC49A-F358-410D-A5CC-D62DAC7D624F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "92B4D260-9A8E-443B-8792-4FFD22137639",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6772D5F3-35EE-4C94-B6D5-31500F440CCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CAF0FE9D-6A93-4F82-8CD7-0CB61079AC1C",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4245AED2-3F58-40D0-BF8A-8E930E1730B7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2357ABBA-34A0-4D0D-8204-B47B29360574",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "40F38253-92F5-4A3A-AA07-292F7542D8A6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C1538F5-0FFE-4186-BB66-937CD0D1B5B3",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518-4_pn\\/dp_mfp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3BC4FA01-8DDB-41E4-B759-7B504F78AEBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "CB41012B-98EF-4BF3-B103-F70F536E625E",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F37885E-AC96-4043-892F-55AEFAFA675D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "18798AFB-14A8-412A-9886-71F403A888FC",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518f-4_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB469732-E3C2-45BC-8F65-C1B6A676A974",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518hf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1475BB2A-72B0-44E1-9B0C-3D9DC61E8528",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518hf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "914D507E-5C6E-4BA7-B5EA-549A01E0C34D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518t-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "931D71AF-75B0-41BA-A0D8-C84EC4D5A350",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518t-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EF0A62F-8EC0-4EB8-821A-14B17D87DD8A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_1518tf-4_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "5AA99065-A472-46E7-B65D-13424D3296BD",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_1518tf-4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "223AA9C0-89FA-459D-949F-FB9D3551C06F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E91666-3BEA-4F79-ACF0-F8FA58541E06",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E41F61DB-1A84-45AC-8A81-5D986065F45B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_15prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B490F5F0-3B3C-4501-AA0B-BED085534CB8",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_15prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FEBA7381-0C6B-4A47-94D7-0255EEF0CFA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513pro-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E5513224-CDB4-4E7F-A296-131555F0CC93",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513pro-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CF97D6C1-6212-4437-84D7-9812FB3FE7DF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_cpu_cpu_1513prof-2_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7803F3CE-F6DA-441C-A5AB-DE1FF0C56DF1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_cpu_cpu_1513prof-2:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "98F27F5F-E107-407A-9EAB-D8D1D7406473",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "755E97AB-6AD7-454D-9E35-3472B82A23F1",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1542sp-1_irc_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF3E5DDA-1BD4-4511-A2C8-4B5D40E6755E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "214EDE7C-033D-4FB1-8FE1-17E99D7A9033",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A60FC550-A518-46BF-9124-E21DD654981C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "DA976CCF-1C34-461E-AEB3-DAEF0D251BDE",
              "versionEndExcluding": "3.0.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_et_200sp_cp_1543sp-1_isec_tx_rail:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "25634AD2-2CC0-45AF-B5DE-39D30CBA91A4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C665C2D3-80A3-4969-BABB-004B97A21B7A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C9A5678E-9EAA-441A-AC77-94F824D64AEE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DD7DA13A-BF1F-4501-A259-190BA4996B23",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE4D4D21-9868-4FA3-89A8-1EEC473383EF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "83900616-A91E-45B2-AE17-1D68E1B8BA57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88F00AE1-D55A-4C7C-A421-2B89BDFE4C9D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A856E00C-965C-478F-A6D8-79EDCF342DDF",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7D038857-CED3-4312-9B86-36DC10A0398F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_315-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "61D2CA3D-D97B-4AC7-AAA7-F2444667B74B",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_315-2_pn\\/dp:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1FC6FF34-3155-4CF8-88D5-4EAE00B32163",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "88CEE87A-2A0D-45E9-967E-F88EC87EE687",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_s7-300_cpu_317-2_pn\\/dp:v6:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A5CDFEA-E5F2-419F-A1B3-D98C44D38D84",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siplus_tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "820BF9F7-4283-4924-82F5-943172C32E2F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siplus_tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "074FDC9C-CB36-4C67-82C8-1B930FF1269F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:tim_1531_irc_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4068A0FB-8DAC-40AA-A016-5DE552EF20AA",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:tim_1531_irc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "C1D94BEB-BBFB-4258-9835-87DBBB999239",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
    },
    {
      "lang": "es",
      "value": "Los dispositivos afectados no procesan correctamente ciertos paquetes especialmente manipulados enviados al puerto 102/tcp, lo que podr\u00eda permitir a un atacante provocar una denegaci\u00f3n de servicio en el dispositivo."
    }
  ],
  "id": "CVE-2021-40365",
  "lastModified": "2024-11-21T06:23:57.543",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Secondary"
      }
    ]
  },
  "published": "2022-12-13T16:15:14.650",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-20"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2013-04-22 03:27
Modified
2024-11-21 01:52
Severity ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2A37383F-B3F7-423C-B956-87926E38B323",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC545350-FD53-4B2E-886F-E20F12260C9B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1211c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3D4A8F2-6ACC-4809-8320-7A0305741069",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1211c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "3871C0C9-C65E-4E0B-9CA8-75E60066297F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EBDF670-EA1F-45A4-8C2B-C52B5D2AF565",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "07849777-92E7-41D2-9128-F8D20DE15391",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1212fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0EC634AF-318C-4280-B0E3-1DE20C98962C",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1212fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "68B3573B-A31E-4489-B2DD-B01B5C1D03CB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D4A46E17-22DF-4FEB-B290-E209AF511B8E",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B640800C-9263-4BEA-9DA5-1323932540BD",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1214c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "233B1E82-769D-43AA-A051-CBAB0BD5F496",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1214c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "FE17584A-BF7A-48B8-A9CB-477663766C63",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215_fc_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1CBD5520-7F19-44DE-AA9B-1D00475B987F",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215_fc:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "76C7D55C-8D99-4E2F-A254-1BDE2B12A203",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1215c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9E1B49EF-9276-47C7-ACE7-965B465BF202",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1215c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "CC4698CF-F935-4707-BA91-7E3650C7956C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_s7-1200_cpu_1217c_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "919785E4-03B8-4BDF-9C3C-90538E24D13E",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_s7-1200_cpu_1217c:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "232279DE-CF1C-4A3C-886D-B4CE3F104F09",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port)."
    },
    {
      "lang": "es",
      "value": "Siemens SIMATIC S7-1200 PLCs v2.x y v3.x permite a atacantes remotos causar una denegaci\u00f3n de servicio mediante paquetes especialmente creados hacia el puerto UDP 161 (puerto SNMP)"
    }
  ],
  "id": "CVE-2013-2780",
  "lastModified": "2024-11-21T01:52:21.247",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-04-22T03:27:13.063",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2012-3040
Vulnerability from cvelistv5
Published
2012-10-10 18:00
Modified
2024-08-06 19:50
Severity ?
Summary
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:50:05.460Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "50816",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/50816"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf"
          },
          {
            "name": "86130",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://osvdb.org/86130"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://en.securitylab.ru/lab/PT-2012-50"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-10-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-02-02T10:00:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "50816",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/50816"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf"
        },
        {
          "name": "86130",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://osvdb.org/86130"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://en.securitylab.ru/lab/PT-2012-50"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-3040",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "50816",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/50816"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-283-01.pdf"
            },
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-279823.pdf"
            },
            {
              "name": "86130",
              "refsource": "OSVDB",
              "url": "http://osvdb.org/86130"
            },
            {
              "name": "http://en.securitylab.ru/lab/PT-2012-50",
              "refsource": "MISC",
              "url": "http://en.securitylab.ru/lab/PT-2012-50"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-3040",
    "datePublished": "2012-10-10T18:00:00",
    "dateReserved": "2012-05-30T00:00:00",
    "dateUpdated": "2024-08-06T19:50:05.460Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10936
Vulnerability from cvelistv5
Published
2019-10-10 00:00
Modified
2024-08-04 22:40
Summary
Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition.
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Version: 0   < *
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Version: All versions < V4.6 Patch 01
Siemens SIMATIC CFU PA Version: 0   < V1.2.0
Siemens SIMATIC ET 200AL IM 157-1 PN Version: All versions
Siemens SIMATIC ET 200M (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200MP IM 155-5 PN BA Version: 0   < V4.3.0
Siemens SIMATIC ET 200MP IM 155-5 PN HF Version: 0   < V4.4.0
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIMATIC ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-3 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-4 PN HF Version: 0   < *
Siemens SIMATIC ET 200pro IM 154-8 PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200pro IM 154-8F PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200pro IM 154-8FX PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.17
Siemens SIMATIC ET 200SP IM 155-6 PN BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants) Version: All versions < V1.2.1
Siemens SIMATIC ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIMATIC ET 200SP IM 155-6 PN HS Version: 0   < V4.0.1
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIMATIC ET 200SP IM 155-6 PN/2 HF Version: 0   < V4.2.2
Siemens SIMATIC ET 200SP IM 155-6 PN/3 HF Version: 0   < V4.2.1
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Version: 0   < V2.0
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Version: All versions
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Version: All versions
Siemens SIMATIC ET200ecoPN: IO-Link Master Version: All versions
Siemens SIMATIC ET200S (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC HMI Comfort Panels (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC HMI KTP Mobile Panels Version: 0   < *
Siemens SIMATIC PN/PN Coupler Version: All versions < V4.2.1
Siemens SIMATIC PROFINET Driver Version: All versions < V2.1
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.4.0
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.0
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V2.0
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 319-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Version: All versions < V3.2.17
Siemens SIMATIC S7-400 CPU 412-2 PN V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 414-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 414F-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 416-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 CPU 416F-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Version: 0   < V6.0.9
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Version: 0   < *
Siemens SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) Version: All versions < V8.2.2
Siemens SIMATIC TDC CP51M1 Version: 0   < V1.1.8
Siemens SIMATIC TDC CPU555 Version: 0   < V1.1.1
Siemens SIMATIC WinAC RTX 2010 Version: All versions < V2010 SP3
Siemens SIMATIC WinAC RTX F 2010 Version: All versions < V2010 SP3
Siemens SINAMICS DCM Version: All versions < V1.5 HF1
Siemens SINAMICS DCP Version: All versions < V1.3
Siemens SINAMICS G110M V4.7 PN Control Unit Version: All versions < V4.7 SP10 HF5
Siemens SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants) Version: All versions < V4.7 SP10 HF5
Siemens SINAMICS G130 V4.7 Control Unit Version: All versions < 4.8
Siemens SINAMICS G150 Control Unit Version: All versions < 4.8
Siemens SINAMICS GH150 V4.7 Control Unit Version: All versions
Siemens SINAMICS GL150 V4.7 Control Unit Version: All versions
Siemens SINAMICS GM150 V4.7 Control Unit Version: All versions
Siemens SINAMICS S110 Control Unit Version: 0   < *
Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) Version: 0   < *
Siemens SINAMICS S150 Control Unit Version: All versions < 4.8
Siemens SINAMICS SL150 V4.7 Control Unit Version: All versions < V4.7 HF33
Siemens SINAMICS SM120 V4.7 Control Unit Version: 0   < *
Siemens SINUMERIK 828D Version: All versions < V4.8 SP5
Siemens SINUMERIK 840D sl Version: All versions < V4.8 SP6
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.4.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF Version: 0   < V4.4.0
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Version: 0   < V4.4.0
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN ST Version: 0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS ET 200S IM 151-8 PN/DP CPU Version: All versions < V3.2.17
Siemens SIPLUS ET 200S IM 151-8F PN/DP CPU Version: All versions < V3.2.17
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN HF TX RAIL Version: 0   < V4.2.2
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Version: 0   < *
Siemens SIPLUS NET PN/PN Coupler Version: All versions < V4.2.1
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.17
Siemens SIPLUS S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.17
Siemens SIPLUS S7-400 CPU 414-3 PN/DP V7 Version: 0   < V7.0.3
Siemens SIPLUS S7-400 CPU 416-3 PN/DP V7 Version: 0   < V7.0.3
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "dk_standard_ethernet_controller_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:ek-ertec_200_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ek-ertec_200_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:ek-ertec_200p_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ek-ertec_200p_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "4.6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_cfu_pa",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et200ecopn_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et200ecopn_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et200s_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et200s_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200al_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200al_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200m_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200m_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200mp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200mp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.3.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200pro_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200pro_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200s_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200s_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_et_200sp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_et_200sp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_hmi_comfort_outdoor_panels",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_pn\\/pn_coupler_6es7158-3ad01-0xa0",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.2.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_profinet_driver:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_profinet_driver",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_314_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_314_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_315-2_dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_315-2_dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_315f-2_dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_315f-2_dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_317-2_dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_317-2_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_317-2_pn\\/dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-300_cpu_319-3_pn\\/dp_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-300_cpu_319-3_pn\\/dp_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.2.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_cpu_412-2_pn",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v7.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_cpu_414-3_pn\\/dp",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v7.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_cpu_416-3_pn\\/dp",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "v7.0.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-400_h_v6_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_h_v6_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "v6.0.9",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-400_pn\\/dp_v6_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-400_pn\\/dp_v6_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_s7-410_cpu_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-410_cpu_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v8.2.2",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-1200_cpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-1200_cpu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.4.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-1500_cpu",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_s7-1500_controller:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_s7-1500_controller",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2.0",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_tdc_cp51m1_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.1.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_tdc_cpu555_firmware",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.1.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:siemens:simatic_winac_rtx_2010:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_winac_rtx_2010",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2010_sp3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:simatic_winac_rtx_\\(f\\)_2010:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "simatic_winac_rtx_\\(f\\)_2010",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v2010_sp3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_dcm",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.5_hf1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_dcp",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v1.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g110m",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7_sp10_hf5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g120:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g120",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7_sp10_hf5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g130",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_g150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_gh150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_gl150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_gm150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_s110:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_s110",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_s120",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_sl150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_sl150",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.7_hf33",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinamics_sm120",
            "vendor": "siemens",
            "versions": [
              {
                "lessThanOrEqual": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinumerik_828d",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8_sp5",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sinumerik_840d_sl",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v4.8_sp6",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:siemens:siplus_s7-300_cpu_314:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "siplus_s7-300_cpu_314",
            "vendor": "siemens",
            "versions": [
              {
                "lessThan": "v3.3.17",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-10936",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-09T14:36:59.481395Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-09T15:59:12.602Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.253Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6 Patch 01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CFU PA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Outdoor Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI KTP Mobile Panels",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PROFINET Driver",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 412-2 PN V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M V4.7 PN Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP10 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120 V4.7 PN Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP10 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 4.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 4.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GH150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GL150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS GM150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c 4.8"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SL150 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF33"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS SM120 V4.7 Control Unit",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 SP6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS NET PN/PN Coupler",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices improperly handle large amounts of specially crafted UDP packets.\r\n\r\nThis could allow an unauthenticated remote attacker to trigger a denial of service condition."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-09T12:03:55.957Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-473245.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10936",
    "datePublished": "2019-10-10T00:00:00",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.253Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-44693
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-04 04:25
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1507D TF Version: All versions < V2.9.7
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V21.9.7
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.6.0
Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511T-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513R-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515T-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 Software Controller V2 Version: All versions < V21.9.7
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V5.0
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.966Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1284",
              "description": "CWE-1284: Improper Validation of Specified Quantity in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:53.197Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44693",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2021-12-07T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.966Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2012-3037
Vulnerability from cvelistv5
Published
2012-09-25 10:00
Modified
2024-09-17 01:26
Severity ?
Summary
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T19:50:05.345Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://en.securitylab.ru/lab/PT-2012-48"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-09-25T10:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://en.securitylab.ru/lab/PT-2012-48"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2012-3037",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificate."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-240718.pdf"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-263-01.pdf"
            },
            {
              "name": "http://en.securitylab.ru/lab/PT-2012-48",
              "refsource": "MISC",
              "url": "http://en.securitylab.ru/lab/PT-2012-48"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2012-3037",
    "datePublished": "2012-09-25T10:00:00Z",
    "dateReserved": "2012-05-30T00:00:00Z",
    "dateUpdated": "2024-09-17T01:26:53.895Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-44694
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-04 04:25
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1507D TF Version: All versions < V2.9.7
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V21.9.7
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.6.0
Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511T-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513R-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515T-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 Software Controller V2 Version: All versions < V21.9.7
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V5.0
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.926Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1287",
              "description": "CWE-1287: Improper Validation of Specified Type of Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:54.785Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44694",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2021-12-07T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.926Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-37205
Vulnerability from cvelistv5
Published
2022-02-09 15:16
Modified
2024-08-04 01:16
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions >= V21.9 < V21.9.4
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions >= V4.5.0 < V4.5.2
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions >= V2.9.2 < V2.9.4
Siemens SIMATIC S7-1500 Software Controller Version: All versions >= V21.9 < V21.9.4
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions >= V4.0 < V4.0 SP1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.897Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-401",
              "description": "CWE-401: Missing Release of Memory after Effective Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:55.468Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37205",
    "datePublished": "2022-02-09T15:16:57",
    "dateReserved": "2021-07-21T00:00:00",
    "dateUpdated": "2024-08-04T01:16:03.897Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2013-0700
Vulnerability from cvelistv5
Published
2013-04-22 01:00
Modified
2024-08-06 14:33
Severity ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:33:05.470Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T14:06:52",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-0700",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-0700",
    "datePublished": "2013-04-22T01:00:00",
    "dateReserved": "2012-12-19T00:00:00",
    "dateUpdated": "2024-08-06T14:33:05.470Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-3449
Vulnerability from cvelistv5
Published
2021-03-25 14:25
Modified
2024-09-17 03:43
Severity ?
Summary
An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).
References
https://www.openssl.org/news/secadv/20210325.txt
https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJdvendor-advisory
https://www.debian.org/security/2021/dsa-4875vendor-advisory
http://www.openwall.com/lists/oss-security/2021/03/27/1mailing-list
http://www.openwall.com/lists/oss-security/2021/03/27/2mailing-list
http://www.openwall.com/lists/oss-security/2021/03/28/3mailing-list
http://www.openwall.com/lists/oss-security/2021/03/28/4mailing-list
https://security.gentoo.org/glsa/202103-03vendor-advisory
https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/vendor-advisory
https://www.oracle.com/security-alerts/cpuApr2021.html
https://www.tenable.com/security/tns-2021-10
https://www.tenable.com/security/tns-2021-09
https://security.netapp.com/advisory/ntap-20210513-0002/
https://security.netapp.com/advisory/ntap-20210326-0006/
https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc
https://www.tenable.com/security/tns-2021-06
https://www.tenable.com/security/tns-2021-05
https://kc.mcafee.com/corporate/index?page=content&id=SB10356
https://www.oracle.com//security-alerts/cpujul2021.html
https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf
https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845
https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013
https://lists.debian.org/debian-lts-announce/2021/08/msg00029.htmlmailing-list
https://www.oracle.com/security-alerts/cpuoct2021.html
https://www.oracle.com/security-alerts/cpuapr2022.html
https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf
https://www.oracle.com/security-alerts/cpujul2022.html
https://security.netapp.com/advisory/ntap-20240621-0006/
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T16:53:17.609Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.openssl.org/news/secadv/20210325.txt"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
          },
          {
            "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
          },
          {
            "name": "DSA-4875",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2021/dsa-4875"
          },
          {
            "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
          },
          {
            "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
          },
          {
            "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
          },
          {
            "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
          },
          {
            "name": "GLSA-202103-03",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202103-03"
          },
          {
            "name": "FEDORA-2021-cbf14ab8f9",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-10"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-09"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-06"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/tns-2021-05"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
          },
          {
            "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenSSL",
          "vendor": "OpenSSL",
          "versions": [
            {
              "status": "affected",
              "version": "Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Peter K\u00e4stle (Nokia) and Samuel Sapalski (Nokia)"
        }
      ],
      "datePublic": "2021-03-25T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j)."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "lang": "eng",
              "url": "https://www.openssl.org/policies/secpolicy.html#High",
              "value": "High"
            },
            "type": "unknown"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "NULL pointer dereference",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-21T19:05:57.096577",
        "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
        "shortName": "openssl"
      },
      "references": [
        {
          "url": "https://www.openssl.org/news/secadv/20210325.txt"
        },
        {
          "url": "https://git.openssl.org/gitweb/?p=openssl.git%3Ba=commitdiff%3Bh=fb9fa6b51defd48157eeb207f52181f735d96148"
        },
        {
          "name": "20210325 Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd"
        },
        {
          "name": "DSA-4875",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.debian.org/security/2021/dsa-4875"
        },
        {
          "name": "[oss-security] 20210327 OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
        },
        {
          "name": "[oss-security] 20210327 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
        },
        {
          "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
        },
        {
          "name": "[oss-security] 20210328 Re: OpenSSL 1.1.1 CVE-2021-3450 CA certificate check bypass with X509_V_FLAG_X509_STRICT, CVE-2021-3449 NULL pointer deref in signature_algorithms processing",
          "tags": [
            "mailing-list"
          ],
          "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
        },
        {
          "name": "GLSA-202103-03",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202103-03"
        },
        {
          "name": "FEDORA-2021-cbf14ab8f9",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/CCBFLLVQVILIVGZMBJL3IXZGKWQISYNP/"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuApr2021.html"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-10"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-09"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
        },
        {
          "url": "https://security.FreeBSD.org/advisories/FreeBSD-SA-21:07.openssl.asc"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-06"
        },
        {
          "url": "https://www.tenable.com/security/tns-2021-05"
        },
        {
          "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=SB10356"
        },
        {
          "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
        },
        {
          "url": "https://kb.pulsesecure.net/articles/Pulse_Security_Advisories/SA44845"
        },
        {
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0013"
        },
        {
          "name": "[debian-lts-announce] 20210831 [SECURITY] [DLA 2751-1] postgresql-9.6 security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
        },
        {
          "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
        }
      ],
      "title": "NULL pointer deref in signature_algorithms processing"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5",
    "assignerShortName": "openssl",
    "cveId": "CVE-2021-3449",
    "datePublished": "2021-03-25T14:25:13.659307Z",
    "dateReserved": "2021-03-17T00:00:00",
    "dateUpdated": "2024-09-17T03:43:55.497Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-37204
Vulnerability from cvelistv5
Published
2022-02-09 15:16
Modified
2024-08-04 01:16
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller family Version: All versions >= V2.9.2 < V2.9.4
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V21.9
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions >= V21.9 < V21.9.4
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux Version: All versions
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.5.0
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions >= V4.5.0 < V4.5.2
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.9.2
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions >= V2.9.2 < V2.9.4
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V21.9
Siemens SIMATIC S7-1500 Software Controller Version: All versions >= V21.9 < V21.9.4
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V4.0
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions >= V4.0 < V4.0 SP1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.812Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003c V2.9.2), SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.5.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.9.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003c V21.9), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003c V4.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packet over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-672",
              "description": "CWE-672: Operation on a Resource after Expiration or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:54.435Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37204",
    "datePublished": "2022-02-09T15:16:56",
    "dateReserved": "2021-07-21T00:00:00",
    "dateUpdated": "2024-08-04T01:16:03.812Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2013-2780
Vulnerability from cvelistv5
Published
2013-04-22 01:00
Modified
2024-08-06 15:44
Severity ?
Summary
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:44:33.607Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2012-12-20T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port)."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-10T14:06:51",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2780",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port)."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-724606.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-724606.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2780",
    "datePublished": "2013-04-22T01:00:00",
    "dateReserved": "2013-04-11T00:00:00",
    "dateUpdated": "2024-08-06T15:44:33.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-42029
Vulnerability from cvelistv5
Published
2022-04-12 09:07
Modified
2024-08-04 03:22
Severity ?
Summary
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions < V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server.
Impacted products
Vendor Product Version
Siemens SIMATIC STEP 7 (TIA Portal) V16 Version: All versions < V16 Update 5
Siemens SIMATIC STEP 7 (TIA Portal) V17 Version: All versions < V17 Update 2
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T03:22:25.804Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V16",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16 Update 5"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284: Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:30",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-42029",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC STEP 7 (TIA Portal) V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 (TIA Portal) V16",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16 Update 5"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 (TIA Portal) V17",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V17 Update 2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) V15 (All versions), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 5), SIMATIC STEP 7 (TIA Portal) V17 (All versions \u003c V17 Update 2). An attacker could achieve privilege escalation on the web server of certain devices due to improper access control vulnerability in the engineering system software. The attacker needs to have direct access to the impacted web server."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284: Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-350757.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-42029",
    "datePublished": "2022-04-12T09:07:30",
    "dateReserved": "2021-10-06T00:00:00",
    "dateUpdated": "2024-08-04T03:22:25.804Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10929
Vulnerability from cvelistv5
Published
2019-08-13 18:55
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.
Impacted products
Vendor Product Version
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V20.8
Siemens SIMATIC HMI Panel (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC NET PC Software V14 Version: All versions < V14 SP1 Update 14
Siemens SIMATIC NET PC Software V15 Version: All versions
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.4.0
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions < V2.8.1
Siemens SIMATIC S7-1500 Software Controller Version: All versions < V20.8
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V3.0
Siemens SIMATIC STEP 7 (TIA Portal) Version: All versions < V16
Siemens SIMATIC WinCC (TIA Portal) Version: All versions < V16
Siemens SIMATIC WinCC OA Version: All versions < V3.16 P013
Siemens SIMATIC WinCC Runtime Advanced Version: All versions < V16
Siemens SIMATIC WinCC Runtime Professional Version: All versions < V16
Siemens TIM 1531 IRC (incl. SIPLUS NET variants) Version: All versions < V2.1
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.230Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC CP 1626",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC HMI Panel (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V14",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1 Update 14"
            }
          ]
        },
        {
          "product": "SIMATIC NET PC Software V15",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "product": "SIMATIC STEP 7 (TIA Portal)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC (TIA Portal)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC OA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.16 P013"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "SIMATIC WinCC Runtime Professional",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V16"
            }
          ]
        },
        {
          "product": "TIM 1531 IRC (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-327",
              "description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:07",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10929",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC CP 1626",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC HMI Panel (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V14",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V14 SP1 Update 14"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC NET PC Software V15",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC STEP 7 (TIA Portal)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC (TIA Portal)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC OA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.16 P013"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC WinCC Runtime Professional",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V16"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "TIM 1531 IRC (incl. SIPLUS NET variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC STEP 7 (TIA Portal) (All versions \u003c V16), SIMATIC WinCC (TIA Portal) (All versions \u003c V16), SIMATIC WinCC OA (All versions \u003c V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions \u003c V16), SIMATIC WinCC Runtime Professional (All versions \u003c V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions \u003c V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-273799.pdf"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10929",
    "datePublished": "2019-08-13T18:55:57",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.230Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-40365
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-04 02:44
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1507D TF Version: All versions < V2.9.7
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V21.9.7
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.6.0
Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511T-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513R-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515T-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 Software Controller V2 Version: All versions < V21.9.7
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V5.0
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T02:44:09.179Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20: Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:51.565Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-40365",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2021-09-01T00:00:00",
    "dateUpdated": "2024-08-04T02:44:09.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2022-30694
Vulnerability from cvelistv5
Published
2022-11-08 00:00
Modified
2024-08-03 06:56
Summary
The login endpoint /FormLogin in affected web services does not apply proper origin checking. This could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack.
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1507D TF Version: All versions < V2.9.7
Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200S IM151-8 PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200S IM151-8F PN/DP CPU Version: All versions < V3.2.19
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V21.9.7
Siemens SIMATIC PC Station Version: All versions >= V2.1
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.6.0
Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511T-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513R-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515T-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 Software Controller V2 Version: All versions < V21.9.7
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.19
Siemens SIMATIC S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 319-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP Version: All versions < V3.2.19
Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Version: All versions
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V5.0
Siemens SIMATIC WinCC Runtime Advanced Version: All versions < V17 Update 5
Siemens SINUMERIK ONE Version: All versions < V6.22
Siemens SIPLUS ET 200S IM151-8 PN/DP CPU Version: All versions < V3.2.19
Siemens SIPLUS ET 200S IM151-8F PN/DP CPU Version: All versions < V3.2.19
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP Version: All versions < V3.3.19
Siemens SIPLUS S7-300 CPU 315-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-300 CPU 317-2 PN/DP Version: All versions < V3.2.19
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP Version: All versions < V3.2.19
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:56:13.567Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM154-8FX PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PC Station",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 315T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU 319F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V17 Update 5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK ONE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.22"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8 PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200S IM151-8F PN/DP CPU",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 314C-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 315F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-300 CPU 317F-2 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.19"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The login endpoint /FormLogin in affected web services does not apply proper origin checking.\r\n\r\nThis could allow authenticated remote attackers to track the activities of other users via a login cross-site request forgery attack."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-352",
              "description": "CWE-352: Cross-Site Request Forgery (CSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:58.151Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-478960.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-30694",
    "datePublished": "2022-11-08T00:00:00",
    "dateReserved": "2022-05-13T00:00:00",
    "dateUpdated": "2024-08-03T06:56:13.567Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2019-10943
Vulnerability from cvelistv5
Published
2019-08-13 18:55
Modified
2024-08-04 22:40
Severity ?
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.602Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.4.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.8.1"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V20.8"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V3.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353: Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-10T11:16:23",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2019-10943",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC Drive Controller family",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V4.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V2.8.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-1500 Software Controller",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V20.8"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC S7-PLCSIM Advanced",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003e= V3.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003c V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003c V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.8.1), SIMATIC S7-1500 Software Controller (All versions \u003c V20.8), SIMATIC S7-1500 Software Controller (All versions \u003e= V20.8), SIMATIC S7-PLCSIM Advanced (All versions \u003c V3.0), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-353: Missing Support for Integrity Check"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2019-10943",
    "datePublished": "2019-08-13T18:55:57",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.602Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-37185
Vulnerability from cvelistv5
Published
2022-02-09 15:16
Modified
2024-08-04 01:16
Summary
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.
Impacted products
Vendor Product Version
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions >= V21.9 < V21.9.4
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions >= V4.5.0 < V4.5.2
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Version: All versions >= V2.9.2 < V2.9.4
Siemens SIMATIC S7-1500 Software Controller Version: All versions >= V21.9 < V21.9.4
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions >= V4.0 < V4.0 SP1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T01:16:03.183Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.5.0 \u003c V4.5.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V2.9.2 \u003c V2.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V21.9 \u003c V21.9.4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003e= V4.0 \u003c V4.0 SP1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC Drive Controller family (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions \u003e= V4.5.0 \u003c V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.9.2 \u003c V2.9.4), SIMATIC S7-1500 Software Controller (All versions \u003e= V21.9 \u003c V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions \u003e= V4.0 \u003c V4.0 SP1), SIPLUS TIM 1531 IRC (All versions \u003c V2.3.6), TIM 1531 IRC (All versions \u003c V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-672",
              "description": "CWE-672: Operation on a Resource after Expiration or Release",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-11T09:01:53.394Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-37185",
    "datePublished": "2022-02-09T15:16:44",
    "dateReserved": "2021-07-21T00:00:00",
    "dateUpdated": "2024-08-04T01:16:03.183Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2021-44695
Vulnerability from cvelistv5
Published
2022-12-13 00:00
Modified
2024-08-04 04:25
Summary
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
Impacted products
Vendor Product Version
Siemens SIMATIC Drive Controller CPU 1507D TF Version: All versions < V2.9.7
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) Version: All versions < V21.9.7
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Version: All versions < V4.6.0
Siemens SIMATIC S7-1500 CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511T-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1511TF-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512C-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1513R-1 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515T-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1515TF-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU 1516T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1516TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517F-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517T-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1517TF-3 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518T-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU 1518TF-4 PN/DP Version: All versions < V3.0.1
Siemens SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN Version: All versions < V2.9.7
Siemens SIMATIC S7-1500 Software Controller V2 Version: All versions < V21.9.7
Siemens SIMATIC S7-PLCSIM Advanced Version: All versions < V5.0
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1510SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS ET 200SP CPU 1512SP-1 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511-1 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1511F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1513F-1 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL Version: All versions < V2.9.7
Siemens SIPLUS S7-1500 CPU 1517H-3 PN Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518-4 PN/DP MFP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518F-4 PN/DP Version: All versions < V3.0.1
Siemens SIPLUS S7-1500 CPU 1518HF-4 PN Version: All versions < V3.0.1
Siemens SIPLUS TIM 1531 IRC Version: All versions < V2.3.6
Siemens TIM 1531 IRC Version: All versions < V2.3.6
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:25:16.962Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1504D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Drive Controller CPU 1507D TF",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.6.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511T-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1511TF-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512C-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1513R-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515T-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1515TF-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1516TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517T-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1517TF-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518T-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU 1518TF-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU S7-1518F-4 PN/DP ODK",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1513PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 ET 200pro: CPU 1516PRO-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V21.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1510SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP F-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP CPU 1512SP-1 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511-1 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1511F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1513F-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515F-2 PN T2 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1515R-2 PN TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516-3 PN/DP TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1516F-3 PN/DP RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.9.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1517H-3 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518F-4 PN/DP",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS S7-1500 CPU 1518HF-4 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIM 1531 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected devices don\u0027t process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1286",
              "description": "CWE-1286: Improper Validation of Syntactic Correctness of Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-12T09:31:56.466Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-382653.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44695",
    "datePublished": "2022-12-13T00:00:00",
    "dateReserved": "2021-12-07T00:00:00",
    "dateUpdated": "2024-08-04T04:25:16.962Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",