Search criteria
3 vulnerabilities found for simatic_s7-300_cpu by siemens
FKIE_CVE-2015-2177
Vulnerability from fkie_nvd - Published: 2015-03-07 02:59 - Updated: 2025-04-12 10:46
Severity ?
Summary
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_s7-300_cpu_firmware | * | |
| siemens | simatic_s7-300_cpu | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E4872DF2-8C81-45BA-A606-99D0A75464AC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "602FB384-0DB2-488C-B3CC-96E3A2882976",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus."
},
{
"lang": "es",
"value": "Los dispositivos Siemens SIMATIC S7-300 CPU permiten a atacantes remotos causar una denegaci\u00f3n de servicio (transici\u00f3n a modo de defecto) a trav\u00e9s de paquetes manipulados en (1) puerto TCP 102 o (2) Profibus."
}
],
"id": "CVE-2015-2177",
"lastModified": "2025-04-12T10:46:40.837",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2015-03-07T02:59:09.160",
"references": [
{
"source": "cve@mitre.org",
"url": "http://www.securityfocus.com/bid/72973"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1032040"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"source": "cve@mitre.org",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
},
{
"source": "cve@mitre.org",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"source": "cve@mitre.org",
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.securityfocus.com/bid/72973"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securitytracker.com/id/1032040"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.exploit-db.com/exploits/44802/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2015-2177 (GCVE-0-2015-2177)
Vulnerability from cvelistv5 – Published: 2015-03-07 02:00 – Updated: 2024-08-06 05:10
VLAI?
Summary
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T05:10:14.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"name": "1032040",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1032040"
},
{
"name": "44802",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"name": "72973",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/72973"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-03-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T13:06:10",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"name": "1032040",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1032040"
},
{
"name": "44802",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"name": "72973",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/72973"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-2177",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"name": "1032040",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1032040"
},
{
"name": "44802",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"name": "72973",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/72973"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-2177",
"datePublished": "2015-03-07T02:00:00",
"dateReserved": "2015-03-02T00:00:00",
"dateUpdated": "2024-08-06T05:10:14.423Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2015-2177 (GCVE-0-2015-2177)
Vulnerability from nvd – Published: 2015-03-07 02:00 – Updated: 2024-08-06 05:10
VLAI?
Summary
Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T05:10:14.423Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"name": "1032040",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1032040"
},
{
"name": "44802",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"name": "72973",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/72973"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2015-03-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-10T13:06:10",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"name": "1032040",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1032040"
},
{
"name": "44802",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"name": "72973",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/72973"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2015-2177",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-064-04"
},
{
"name": "1032040",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1032040"
},
{
"name": "44802",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/44802/"
},
{
"name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf",
"refsource": "CONFIRM",
"url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-987029.pdf"
},
{
"name": "72973",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/72973"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-987029.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2015-2177",
"datePublished": "2015-03-07T02:00:00",
"dateReserved": "2015-03-02T00:00:00",
"dateUpdated": "2024-08-06T05:10:14.423Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}