Vulnerabilites related to siemens - simatic_s7-300f_firmware
Vulnerability from fkie_nvd
Published
2019-04-17 14:29
Modified
2024-11-21 03:52
Summary
A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4C096137-C1E3-4D19-87A9-BEB7A081DD1E",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "7EFD4E99-5C66-443F-8B6F-FA01C895DE78",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:simatic_s7-300f_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FE4251D0-0A74-4A47-9510-A92843D927F7",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:simatic_s7-300f:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "C7A17613-A0E1-4CC9-AC56-6AA2C8418275",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:simatic_s7-300fs_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D7FD4F0A-D270-4B72-BEAC-5362B0CCFC23",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:simatic_s7-300fs:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "D9CC39A6-BA9F-487C-9504-5658A2AE0188",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:siemens:simatic_s7-300t_firmware:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "4C311B40-8D03-451B-B5D3-0BB278930743",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:siemens:simatic_s7-300t:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "FC45A7F6-19C9-4485-8A4C-8C14819B095E",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.",
      },
      {
         lang: "es",
         value: "Se ha identificado una vulnerabilidad en las CPUs SIMATIC S7-300 (todas las versiones anteriores a la V3.X.16). Las CPU afectadas comprueban incorrectamente los paquetes de comunicación S7 que podrían causar una condición de denegación de servicio (DoS) de la CPU. La CPU permanecerá en modo DEFECT hasta el reinicio manual. La explotación con éxito requiere que un atacante pueda enviar un paquete de comunicación S7 especialmente creado a una interfaz de comunicación de la CPU. Esto incluye Ethernet, PROFIBUS y Multi Point Interfaces (MPI). No se requieren interacción ni privilegios del usuario para explotar la vulnerabilidad de seguridad. La vulnerabilidad podría causar una condición de denegación de servicio (DoS) de la funcionalidad principal de la CPU, comprometiendo la disponibilidad del sistema. En el momento de la publicación de asesoramiento, no se conocía la explotación pública de esta vulnerabilidad de seguridad. Siemens confirma la vulnerabilidad de seguridad y proporciona mitigaciones para resolver el problema de seguridad.",
      },
   ],
   id: "CVE-2018-16561",
   lastModified: "2024-11-21T03:52:59.010",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "HIGH",
            cvssData: {
               accessComplexity: "LOW",
               accessVector: "NETWORK",
               authentication: "NONE",
               availabilityImpact: "COMPLETE",
               baseScore: 7.8,
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               vectorString: "AV:N/AC:L/Au:N/C:N/I:N/A:C",
               version: "2.0",
            },
            exploitabilityScore: 10,
            impactScore: 6.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: false,
         },
      ],
      cvssMetricV30: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "HIGH",
               baseScore: 7.5,
               baseSeverity: "HIGH",
               confidentialityImpact: "NONE",
               integrityImpact: "NONE",
               privilegesRequired: "NONE",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
               version: "3.0",
            },
            exploitabilityScore: 3.9,
            impactScore: 3.6,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2019-04-17T14:29:03.370",
   references: [
      {
         source: "productcert@siemens.com",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-306710.pdf",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://cert-portal.siemens.com/productcert/pdf/ssa-306710.pdf",
      },
   ],
   sourceIdentifier: "productcert@siemens.com",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "NVD-CWE-noinfo",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}

cve-2018-16561
Vulnerability from cvelistv5
Published
2019-04-17 13:38
Modified
2024-08-05 10:24
Severity ?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.
Impacted products
Vendor Product Version
Siemens SIMATIC S7-300 CPUs Version: All versions < V3.X.16
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-05T10:24:32.860Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://cert-portal.siemens.com/productcert/pdf/ssa-306710.pdf",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "SIMATIC S7-300 CPUs",
               vendor: "Siemens",
               versions: [
                  {
                     status: "affected",
                     version: "All versions < V3.X.16",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "Improper Input Validation",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2019-04-17T13:38:34",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               tags: [
                  "x_refsource_MISC",
               ],
               url: "https://cert-portal.siemens.com/productcert/pdf/ssa-306710.pdf",
            },
         ],
         x_legacyV4Record: {
            CVE_data_meta: {
               ASSIGNER: "productcert@siemens.com",
               ID: "CVE-2018-16561",
               STATE: "PUBLIC",
            },
            affects: {
               vendor: {
                  vendor_data: [
                     {
                        product: {
                           product_data: [
                              {
                                 product_name: "SIMATIC S7-300 CPUs",
                                 version: {
                                    version_data: [
                                       {
                                          version_value: "All versions < V3.X.16",
                                       },
                                    ],
                                 },
                              },
                           ],
                        },
                        vendor_name: "Siemens",
                     },
                  ],
               },
            },
            data_format: "MITRE",
            data_type: "CVE",
            data_version: "4.0",
            description: {
               description_data: [
                  {
                     lang: "eng",
                     value: "A vulnerability has been identified in SIMATIC S7-300 CPUs (All versions < V3.X.16). The affected CPUs improperly validate S7 communication packets which could cause a Denial-of-Service condition of the CPU. The CPU will remain in DEFECT mode until manual restart. Successful exploitation requires an attacker to be able to send a specially crafted S7 communication packet to a communication interface of the CPU. This includes Ethernet, PROFIBUS, and Multi Point Interfaces (MPI). No user interaction or privileges are required to exploit the security vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the core functionality of the CPU, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens confirms the security vulnerability and provides mitigations to resolve the security issue.",
                  },
               ],
            },
            problemtype: {
               problemtype_data: [
                  {
                     description: [
                        {
                           lang: "eng",
                           value: "Improper Input Validation",
                        },
                     ],
                  },
               ],
            },
            references: {
               reference_data: [
                  {
                     name: "https://cert-portal.siemens.com/productcert/pdf/ssa-306710.pdf",
                     refsource: "MISC",
                     url: "https://cert-portal.siemens.com/productcert/pdf/ssa-306710.pdf",
                  },
               ],
            },
         },
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2018-16561",
      datePublished: "2019-04-17T13:38:34",
      dateReserved: "2018-09-06T00:00:00",
      dateUpdated: "2024-08-05T10:24:32.860Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}