All the vulnerabilites related to siemens - simatic_s7-400_cpu_414-3_pn\/dp
Vulnerability from fkie_nvd
Published
2016-12-17 03:59
Modified
2024-11-21 03:00
Severity ?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "76189399-9032-4695-A976-8415E26B0DB8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", "matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A773F92D-E5C0-4B51-8214-19BFE6BC7638", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3C5065F-C0B9-4427-A9D2-072AFF3FCA69", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A340DA65-BA46-4F72-8951-93135F9F6602", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "7167E5B0-D278-4F63-B5CD-39DBDF336089", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6EBD5F0-16A6-466B-80E5-B95DDBDE2FA3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "6498C679-46A3-4F87-9278-F64D2194E1F5", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "85F8C306-45F5-429B-B932-0278A9B909B7", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0E162F8-B37A-4FFA-A523-FA6227372D37", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "8CD1CA5C-F729-4311-9E78-156BB6DE31A7", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "20E69856-A628-4B9D-9184-7FB9A924193E", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC8F19-313A-4C74-A68A-AAC320B123CE", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "195259DF-8ABE-47A9-9A13-6BDAA25AA898", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "3412299F-5778-4290-A80C-29BC6F46F701", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC41E925-88AF-4D33-AC49-CE5FEAAF2105", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "61363AEF-CBDB-4405-A605-4997798D38D8", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "2CFC71AB-3ACF-4E7E-B83E-31E02DEBDA48", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*", "matchCriteriaId": "711A91B2-EB16-418B-AA63-56DFD40075D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-300 (todas las versiones), la familia de CPU SIMATIC S7-300 (incluidas las CPU ET200 relacionadas y las variantes SIPLUS) (todas las versiones), SIMATIC S7-400 PN / DP V6 y familias de CPU inferiores (incl. variantes SIPLUS) (todas las versiones), familia de CPU SIMATIC S7-400 PN / DP V7 (incl. variantes SIPLUS) (todas las versiones), SIMATIC S7-400 V6 y familia de CPU anterior (todas las versiones), SIMATIC S7-400 Familia de CPU V7 (todas las versiones). Los paquetes especialmente dise\u00f1ados enviados al puerto 80 / tcp podr\u00edan hacer que los dispositivos afectados entren en modo defectuoso. Se requiere un reinicio en fr\u00edo para recuperar el sistema." } ], "id": "CVE-2016-9158", "lastModified": "2024-11-21T03:00:43.150", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-12-17T03:59:00.187", "references": [ { "source": "productcert@siemens.com", "url": "http://www.securityfocus.com/bid/94820" }, { "source": "productcert@siemens.com", "url": "http://www.securitytracker.com/id/1037434" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" }, { "source": "productcert@siemens.com", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "source": "productcert@siemens.com", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/94820" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securitytracker.com/id/1037434" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2012-07-31 10:45
Modified
2024-11-21 01:40
Severity ?
Summary
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
siemens | simatic_s7-400_cpu_firmware | 5.0 | |
siemens | simatic_s7-400_cpu_414-3_pn\/dp | * | |
siemens | simatic_s7-400_cpu_416-3_pn\/dp | * | |
siemens | simatic_s7-400_cpu_416f-3_pn\/dp | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:5.0:*:*:*:*:*:*:*", "matchCriteriaId": "39919E63-3D3F-4C51-B513-41CD3B123B55", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "57DF0BD8-3D14-4F59-939C-5DEC6D71A840", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC15EF79-841F-46C3-85D0-DDB7271CA5B9", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "6DFE5363-0BB0-4DEA-AD36-CB6D9CFDD589", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets." }, { "lang": "es", "value": "Dispositivos Siemens SIMATIC S7-400 PN CPU con firmware v5.x, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (modo de transici\u00f3n por defecto e interrupci\u00f3n del servicio) a trav\u00e9s de (1) tr\u00e1fico HTTP mal formado o (2) paquetes IP mal formados" } ], "id": "CVE-2012-3017", "lastModified": "2024-11-21T01:40:07.843", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2012-07-31T10:45:42.403", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-119" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2016-12-17 03:59
Modified
2024-11-21 03:00
Severity ?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "76189399-9032-4695-A976-8415E26B0DB8", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*", "matchCriteriaId": "4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*", "matchCriteriaId": "78399465-EED5-4EBD-A2E1-6FE0BD01EDB4", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E8FD8E6D-0527-4215-B6F0-5824011433FB", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A773F92D-E5C0-4B51-8214-19BFE6BC7638", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "E3C5065F-C0B9-4427-A9D2-072AFF3FCA69", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A340DA65-BA46-4F72-8951-93135F9F6602", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "7167E5B0-D278-4F63-B5CD-39DBDF336089", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F6EBD5F0-16A6-466B-80E5-B95DDBDE2FA3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*", "matchCriteriaId": "6498C679-46A3-4F87-9278-F64D2194E1F5", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "85F8C306-45F5-429B-B932-0278A9B909B7", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*", "matchCriteriaId": "F0E162F8-B37A-4FFA-A523-FA6227372D37", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "8CD1CA5C-F729-4311-9E78-156BB6DE31A7", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "20E69856-A628-4B9D-9184-7FB9A924193E", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "A1EC8F19-313A-4C74-A68A-AAC320B123CE", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "195259DF-8ABE-47A9-9A13-6BDAA25AA898", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*", "matchCriteriaId": "3412299F-5778-4290-A80C-29BC6F46F701", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "CC41E925-88AF-4D33-AC49-CE5FEAAF2105", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*", "matchCriteriaId": "61363AEF-CBDB-4405-A605-4997798D38D8", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\/dp:-:*:*:*:*:*:*:*", "matchCriteriaId": "2CFC71AB-3ACF-4E7E-B83E-31E02DEBDA48", "vulnerable": false }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*", "matchCriteriaId": "711A91B2-EB16-418B-AA63-56DFD40075D7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-300 (todas las versiones), la familia de CPU SIMATIC S7-300 (incluidas las CPU ET200 relacionadas y las variantes SIPLUS) (todas las versiones), SIMATIC S7-400 PN / DP V6 y familias de CPU inferiores (incl. variantes SIPLUS) (todas las versiones), familia de CPU SIMATIC S7-400 PN / DP V7 (incl. variantes SIPLUS) (todas las versiones), SIMATIC S7-400 V6 y familia de CPU anterior (todas las versiones), SIMATIC S7-400 Familia de CPU V7 (todas las versiones), familia de CPU SIMATIC S7-410 V8 (todas las versiones), familia de CPU SIMATIC S7-410 V8 (incluidas las variantes SIPLUS) (todas las versiones). Un atacante con acceso de red al puerto 102 / tcp (ISO-TSAP) o a trav\u00e9s de Profibus podr\u00eda obtener credenciales del PLC si el nivel de protecci\u00f3n 2 est\u00e1 configurado en los dispositivos afectados." } ], "id": "CVE-2016-9159", "lastModified": "2024-11-21T03:00:43.270", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV30": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.9, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "exploitabilityScore": 2.2, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2016-12-17T03:59:00.233", "references": [ { "source": "productcert@siemens.com", "url": "http://www.securityfocus.com/bid/94820" }, { "source": "productcert@siemens.com", "url": "http://www.securitytracker.com/id/1037434" }, { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" }, { "source": "productcert@siemens.com", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "source": "productcert@siemens.com", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securityfocus.com/bid/94820" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "http://www.securitytracker.com/id/1037434" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2012-07-31 10:45
Modified
2024-11-21 01:40
Severity ?
Summary
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:6.0.1:*:*:*:*:*:*:*", "matchCriteriaId": "479E225E-F2CF-4C54-9185-5482300BC139", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:6.0.2:*:*:*:*:*:*:*", "matchCriteriaId": "C0153991-46CA-43F6-A53B-AAB71641D4AE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:*:*:*:*:*:*:*:*", "matchCriteriaId": "325F1C64-AFDF-418C-9616-293AED36A3D1", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "57DF0BD8-3D14-4F59-939C-5DEC6D71A840", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_414f-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "1492372B-DEAD-4BAA-974F-AE7E6473395E", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC15EF79-841F-46C3-85D0-DDB7271CA5B9", "vulnerable": true }, { "criteria": "cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\/dp:*:*:*:*:*:*:*:*", "matchCriteriaId": "6DFE5363-0BB0-4DEA-AD36-CB6D9CFDD589", "vulnerable": true } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets." }, { "lang": "es", "value": "Dispositivos Siemens SIMATIC S7-400 PN CPU con el firmware v6 anterior a v6.0.3 permite a atacantes remotos causar una denegaci\u00f3n de servicio (interrupci\u00f3n del servicio) a trav\u00e9s de paquetes ICMP especialmente dise\u00f1ados." } ], "id": "CVE-2012-3016", "lastModified": "2024-11-21T01:40:07.717", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ] }, "published": "2012-07-31T10:45:42.327", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "source": "ics-cert@hq.dhs.gov", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "US Government Resource" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2012-3017
Vulnerability from cvelistv5
Published
2012-07-31 10:00
Modified
2024-08-06 19:50
Severity ?
EPSS score ?
Summary
Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets.
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf | x_refsource_CONFIRM | |
http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.567Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2012-07-30T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-13T12:06:04", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3017", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SIMATIC S7-400 PN CPU devices with firmware 5.x allow remote attackers to cause a denial of service (defect-mode transition and service outage) via (1) malformed HTTP traffic or (2) malformed IP packets." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-617264.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617264.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3017", "datePublished": "2012-07-31T10:00:00", "dateReserved": "2012-05-30T00:00:00", "dateUpdated": "2024-08-06T19:50:05.567Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2016-9159
Vulnerability from cvelistv5
Published
2016-12-17 03:34
Modified
2024-08-06 02:42
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/94820 | vdb-entry, x_refsource_BID | |
http://www.securitytracker.com/id/1037434 | vdb-entry, x_refsource_SECTRACK | |
https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05 | x_refsource_MISC | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC S7-300 CPU family |
Version: All versions |
||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T02:42:11.143Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "94820", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1037434" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-300 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 V6 and earlier CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 V7 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-410 V8 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2016-12-16T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Information Exposure", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-03-10T19:16:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "94820", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1037434" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2016-9159", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-300 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 V6 and earlier CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 V7 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-410 V8 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-200: Information Exposure" } ] } ] }, "references": { "reference_data": [ { "name": "94820", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1037434" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2016-9159", "datePublished": "2016-12-17T03:34:00", "dateReserved": "2016-11-03T00:00:00", "dateUpdated": "2024-08-06T02:42:11.143Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2016-9158
Vulnerability from cvelistv5
Published
2016-12-17 03:34
Modified
2024-08-06 02:42
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.
References
▼ | URL | Tags |
---|---|---|
http://www.securityfocus.com/bid/94820 | vdb-entry, x_refsource_BID | |
http://www.securitytracker.com/id/1037434 | vdb-entry, x_refsource_SECTRACK | |
https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05 | x_refsource_MISC | |
https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens AG | SIMATIC S7-300 CPU family |
Version: All versions |
||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T02:42:10.987Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "94820", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1037434" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-300 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 V6 and earlier CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 V7 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2016-12-16T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-03-10T19:16:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "94820", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1037434" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2016-9158", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-300 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 V6 and earlier CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 V7 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "94820", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1037434" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2016-9158", "datePublished": "2016-12-17T03:34:00", "dateReserved": "2016-11-03T00:00:00", "dateUpdated": "2024-08-06T02:42:10.987Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2012-3016
Vulnerability from cvelistv5
Published
2012-07-31 10:00
Modified
2024-08-06 19:50
Severity ?
EPSS score ?
Summary
Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets.
References
▼ | URL | Tags |
---|---|---|
http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf | x_refsource_CONFIRM | |
http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf | x_refsource_CONFIRM |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T19:50:05.465Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "datePublic": "2012-07-30T00:00:00", "descriptions": [ { "lang": "en", "value": "Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2020-04-13T12:06:04", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2012-3016", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Siemens SIMATIC S7-400 PN CPU devices with firmware 6 before 6.0.3 allow remote attackers to cause a denial of service (defect-mode transition and service outage) via crafted ICMP packets." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf", "refsource": "CONFIRM", "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-589272.pdf" }, { "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf", "refsource": "MISC", "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-212-02.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-589272.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2012-3016", "datePublished": "2012-07-31T10:00:00", "dateReserved": "2012-05-30T00:00:00", "dateUpdated": "2024-08-06T19:50:05.465Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }