FKIE_CVE-2011-3321
Vulnerability from fkie_nvd - Published: 2011-09-16 12:35 - Updated: 2025-04-11 00:51
Severity ?
Summary
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_wincc_flexible_runtime | * | |
| siemens | simatic_wincc_runtime | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_flexible_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BA49B1B5-57A3-4405-964F-258B10BAD144",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime:-:*:*:*:advanced:*:*:*",
"matchCriteriaId": "1116304B-6CD9-4D44-BC95-B945D82873A4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308."
},
{
"lang": "es",
"value": "Desbordamiento de buffer de memoria din\u00e1mica en Siemens WinCC Runtime Advanced Loader, tal como se usa en SIMATIC WinCC flexible Runtime y SIMATIC WinCC (TIA Portal) Runtime Advanced, permite a atacantes remotos provocar una denegaci\u00f3n de servicio (corrupci\u00f3n de memoria) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de un paquete modificado al puerto TCP 2308."
}
],
"id": "CVE-2011-3321",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2011-09-16T12:35:26.450",
"references": [
{
"source": "cret@cert.org",
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"source": "cret@cert.org",
"tags": [
"Vendor Advisory"
],
"url": "http://secunia.com/advisories/46011"
},
{
"source": "cret@cert.org",
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"source": "cret@cert.org",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
},
{
"source": "cret@cert.org",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://secunia.com/advisories/46011"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
}
],
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2011-3321 (GCVE-0-2011-3321)
Vulnerability from cvelistv5 – Published: 2011-09-15 21:00 – Updated: 2024-08-06 23:29
VLAI?
Summary
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:29:56.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"name": "simatic-wincc-runtime-bo(69803)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"name": "46011",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/46011"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-28T12:57:01",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"name": "simatic-wincc-runtime-bo(69803)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"name": "46011",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/46011"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-3321",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.automation.siemens.com/WW/view/en/29054992",
"refsource": "MISC",
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"name": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf",
"refsource": "CONFIRM",
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"name": "simatic-wincc-runtime-bo(69803)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"name": "46011",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/46011"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-3321",
"datePublished": "2011-09-15T21:00:00",
"dateReserved": "2011-08-29T00:00:00",
"dateUpdated": "2024-08-06T23:29:56.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-3321 (GCVE-0-2011-3321)
Vulnerability from nvd – Published: 2011-09-15 21:00 – Updated: 2024-08-06 23:29
VLAI?
Summary
Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:29:56.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"name": "simatic-wincc-runtime-bo(69803)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"name": "46011",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/46011"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-28T12:57:01",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"name": "simatic-wincc-runtime-bo(69803)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"name": "46011",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/46011"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-3321",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://support.automation.siemens.com/WW/view/en/29054992",
"refsource": "MISC",
"url": "http://support.automation.siemens.com/WW/view/en/29054992"
},
{
"name": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf",
"refsource": "CONFIRM",
"url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
},
{
"name": "simatic-wincc-runtime-bo(69803)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
},
{
"name": "46011",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/46011"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-3321",
"datePublished": "2011-09-15T21:00:00",
"dateReserved": "2011-08-29T00:00:00",
"dateUpdated": "2024-08-06T23:29:56.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}