All the vulnerabilites related to siemens - sinamics_sh150
Vulnerability from fkie_nvd
Published
2021-02-09 17:15
Modified
2024-11-21 05:06
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6B7A9D84-336F-4CC3-B86D-1BC212726F3E", "versionEndExcluding": "16.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:-:*:*:*:*:*:*", "matchCriteriaId": "91E96941-4D8D-4473-8F6D-DE4D822DD245", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update1:*:*:*:*:*:*", "matchCriteriaId": "AFE4B793-1879-44A3-87B6-A86D7D687FD9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update2:*:*:*:*:*:*", "matchCriteriaId": "41238DBB-A315-498B-A8BC-54AB2EC0A9AF", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16.0:update3:*:*:*:*:*:*", "matchCriteriaId": "109E27B6-587F-4E21-9715-4FFBD43DC744", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "3BCFE761-35C9-43EF-85BC-E8083B9F75CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "50366ACE-B115-448C-A8B2-7903EB070CE7", "versionEndExcluding": "16.0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:-:*:*:*:*:*:*", "matchCriteriaId": "BF124F76-F860-4A11-A358-292499D66629", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update1:*:*:*:*:*:*", "matchCriteriaId": "B4439C50-FFE9-485E-BD82-7896959E04B2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update2:*:*:*:*:*:*", "matchCriteriaId": "7AE2A346-C42B-4B70-8FA8-1B56D9603114", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16.0:update3:*:*:*:*:*:*", "matchCriteriaId": "96414026-2404-4AFD-B55C-1CD93F729110", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*", "matchCriteriaId": "B1CEB200-E38F-4629-9279-5AF065396678", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "04A1F440-A20A-43BF-8B92-A32F355311DA", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "7E108020-A6BA-4C90-BB0A-6E80F3341731", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "FFC05D55-994D-4F54-AA17-FB4D3A0191A7", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "C9CD365F-139E-42D9-8B1E-31A07E752226", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1AFBC5A7-6DED-4237-8ACC-D0C4C582DE7E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "F587131C-64F3-4B89-902C-809B5F095BF3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "28DB0BC6-E60A-4798-80DC-125EF25B3A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "1915386C-8C70-479B-B9AE-2A970CD773C0", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels (incl. Variantes SIPLUS) (Todas las versiones anteriores a V16 Update 3a), SIMATIC HMI KTP Mobile Panels (Todas las versiones anteriores a V16 Update 3a), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Los dispositivos afectados con el servicio telnet activado no requieren autenticaci\u00f3n para este servicio. Esto podr\u00eda permitir a un atacante remoto obtener acceso completo al dispositivo. (ZDI-CAN-12046)" } ], "id": "CVE-2020-15798", "lastModified": "2024-11-21T05:06:12.120", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-02-09T17:15:13.437", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Patch, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones anteriores), SINAMICS GL150 (with option X30) (Todas las versiones anteriores), SINAMICS GM150 (with option X30) (Todas las versiones anteriores), SINAMICS SH150 (Todas las versiones anteriores), SINAMICS SL150 (Todas las versiones anteriores), SINAMICS SM120 (Todas las versiones anteriores), SINAMICS SM150 (Todas las versiones anteriores), SINAMICS SM150i (Todas las versiones anteriores). SmartVNC tiene una vulnerabilidad de acceso a memoria fuera de l\u00edmites en el manejador de dise\u00f1o del dispositivo, representado por un flujo de datos binarios en el lado del cliente, que potencialmente puede resultar en la ejecuci\u00f3n de c\u00f3digo" } ], "id": "CVE-2021-27384", "lastModified": "2024-11-21T05:57:53.230", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.677", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-788" } ], "source": "productcert@siemens.com", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con la opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (with option X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC tiene una vulnerabilidad de fuga de asignaci\u00f3n de heap en el codificador Tight del servidor, que podr\u00eda dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio" } ], "id": "CVE-2021-27383", "lastModified": "2024-11-21T05:57:53.060", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.633", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-770" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | Third Party Advisory, US Government Resource |
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). Un atacante remoto podr\u00eda enviar paquetes especialmente dise\u00f1ados al manejador de dise\u00f1o de dispositivos SmartVNC en el lado del cliente, lo que podr\u00eda influir en la cantidad de recursos consumidos y dar lugar a una condici\u00f3n de denegaci\u00f3n de servicio (bucle infinito)" } ], "id": "CVE-2021-27385", "lastModified": "2024-11-21T05:57:53.380", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.727", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-835" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2021-05-12 14:15
Modified
2024-11-21 05:57
Severity ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "C0891D85-C5F4-4CD2-8EFA-84356CE36654", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:-:*:*:*:*:*:*", "matchCriteriaId": "E0005A53-33AD-47AF-B172-CAF423DE213F", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update1:*:*:*:*:*:*", "matchCriteriaId": "9696B0D9-5A66-4747-9437-791EAC150DDA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update2:*:*:*:*:*:*", "matchCriteriaId": "F6AC2BA5-1668-4B71-8812-925AC6554F5A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:16:update3:*:*:*:*:*:*", "matchCriteriaId": "047D0868-3DA6-41CF-A6F9-D15668D536FB", "vulnerable": true } ], "negate": false, "operator": "OR" } ] }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F1FAFD2-1E4D-44F3-87A1-8A1380B980BC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "EBC7AA8D-9046-4111-A263-38343997F984", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150i_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "D6067521-A21D-4B2A-AFB2-2E033F66B63E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150i:-:*:*:*:*:*:*:*", "matchCriteriaId": "A44DEAD8-8DB8-41CC-9495-B842BE76EA8F", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4BF9157D-0089-4569-9AA1-4DEE94140D25", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:*", "matchCriteriaId": "BF977545-395A-4C34-BB22-A1047B5B6E85", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4D780400-0AA8-449C-B754-7167CA878D3D", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DED7F33B-D475-4232-8683-48554A6729F7", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "61CD50EE-6C46-445E-8D46-82768CAAC305", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "DD76CFB0-B5D7-40DC-8D14-FC9C9BACF3CD", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E032554B-7F51-4482-AF55-743FFB5AC352", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:*", "matchCriteriaId": "C6619B0F-7CDC-40A6-89B2-C6067AF45214", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "CFFE3048-EEB0-48A0-BED0-8647284B022B", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:*", "matchCriteriaId": "444DD77F-DB65-4766-A89D-7A679B4CA1E1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:sinamics_sm150_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "33B7E1DE-61B5-4CFC-8640-EB8029CD79D6", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:sinamics_sm150:-:*:*:*:*:*:*:*", "matchCriteriaId": "2AE231E2-2B2B-407A-BF7A-9EA35F394229", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "244D9B27-649C-4983-B374-6A8774771AC5", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "A2530BB3-484C-4D24-82F6-15967C8B7B32", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B5A1FACE-E693-4FDA-944D-0B7F500007B6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7FB4AA4-1F48-4A25-AA21-5F867A38D23E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "6A673BD0-96B5-48CA-B060-A5D01687A764", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "428B633D-55FF-4DB8-B6DD-5E4EEE52A44C", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:*:*:*:*:*:*:*", "matchCriteriaId": "C33A64DD-22A2-4260-929F-7595CD037823", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "9756D206-E295-4B0C-B159-F9A953342E37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "82D6FBBF-FD9B-4AFA-B3E1-8E3341948A37", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D43D2191-DBBD-4F7A-B02A-3DCEE46BF904", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "23C6AD3C-C15B-4B67-88D1-236C10BB12CF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "FEE4201E-E660-4B3E-91EC-B6A7DC35C189", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "F2D6D924-858A-4542-BCD0-A5631F941039", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "309E4D56-6D39-4E8F-8312-FF178B721392", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EDB63639-3101-4F60-8193-EF219D99C128", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "4C6C83EE-3DC7-4CB3-8148-CB24A825274E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C6C72B0-17D7-491E-816A-AF855166A90B", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "322584EF-72C0-4032-A02B-FDFFDCCE3FDE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "C3D5F1BA-2BEA-40A9-8D5B-A612D467C40C", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D14DE5C7-318A-4D08-BB39-1E43F624816A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "FCDAF23F-9272-4DC5-8D46-37FAC08950CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "21FB0305-DF87-42FF-BACA-E8255EA74AA9", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BAA5B299-A45A-4918-AB8F-03A476CEDA17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0C29FD64-C041-4269-BC52-8F91321BC247", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "7182C6C0-7DAD-4446-B14E-8EF46FB0CFA9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "44F6F972-26AF-4A6E-AAD9-B30EBDF52465", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "E57B8F3D-5E02-4F0F-9927-9D7C336EBE56", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "845C78A9-AE0F-42B9-9E25-47F541DF5196", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "B23096F5-3546-41D8-BE30-8698BC0C9B42", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "D7C5AF13-69FF-444F-B84A-130D7413B307", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "66A17FC6-B6AE-4915-8069-68B41F3C87E2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "4C618736-1382-4515-A295-6EC67A2731EA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "BC0AD5A8-768E-4747-AD89-B924D369565E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "4C2FD1E4-4A01-4BFB-9D2A-5A030C37BD96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "0AA5C3DC-E67F-4773-B32C-6B362C94BCBE", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "C96C7676-9A0D-46B5-9C49-5F5CE873E2C1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "AF42C3EA-84A5-4419-ACBA-6A2F8DB994E2", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "105CCE4B-D8F9-43EA-9089-CEE16A410751", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "7C163E7E-C9E3-4FBD-885A-C2E7FB8B845F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "2CD3DD84-BDAC-4583-BD61-799A5F01A5B4", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "0A4F6758-0B36-4546-A7A7-A4C71B63772E", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "12A613F7-4EA4-40FF-931F-EF3C477300DA", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:-:*:*:*:*:*:*", "matchCriteriaId": "4B048552-A26D-419E-9EEA-9AFD9457B70B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update1:*:*:*:*:*:*", "matchCriteriaId": "0E4E1016-F217-4B75-83D7-F73B1C5A54F9", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update2:*:*:*:*:*:*", "matchCriteriaId": "EF2F6982-2C38-4F9B-87A4-AE4404197B7A", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:16:update3:*:*:*:*:*:*", "matchCriteriaId": "7745AA84-BC12-4DBD-90A6-DA294EADB7BF", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "67CFFD89-1FF2-4F25-A5AB-D6FF8F721132", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "BA4B198A-8288-459D-9586-CD402DE23023", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AC4FDB83-702A-41D5-B2A5-BDA58B7E13D2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "D972823A-1128-4222-8910-9CA3D38B472F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "A05007D7-3C49-4192-ABDF-FE94BA7FD1D1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "869AD837-79B1-4F76-947B-7DCAD172BDC0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_7\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "5C152EB8-A13A-4F16-994A-B6D93A017CC3", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_7\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "B531FDD4-2796-4FE9-9F94-E9D461C7C528", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "42F38FBA-7D23-4CB2-9A2D-45616E2A2DFB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "553C9A57-A9D2-47F9-ABA8-042B05DE46C7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "8F5F3B33-2A82-4CDF-A678-76DE13F256D7", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "9FE49F2D-B904-4E48-AAFD-669141B570F6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "729F784C-9AC0-4231-A75A-1FA8373FA31F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "FA61AC05-061D-4EE7-BFEF-568F30B9B883", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_15\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "374BAF2F-0A32-4F1A-B838-894F9E9D3E0F", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels_15\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "39DA22F7-E4B6-4A1E-9CCB-651EBEFD691D", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "6C636FCD-78AE-4FA2-95E5-2BBD5A88DA68", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "FDE42199-9152-41A3-BE56-E6789315CF28", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "040F990F-F3C2-46EF-9E40-FD136A19575F", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "748BFFBC-56BD-42EC-9B5F-0752D2A70D17", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B37490B0-A214-4A62-9B67-934048921C1E", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "3D7B9F45-5749-4F36-961D-6C5D650ADA07", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_4\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F544593D-368B-4EC1-8448-8C2BA1301216", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_4\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "D63658BB-2364-4DE5-904B-2367B70294AC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A9D26D9F-7081-42B2-8AE4-D04E8429B88D", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "5F902732-9944-4821-BCFB-9937D1301FF6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B0C061AC-3E64-4667-A0E7-DD58B2E5A014", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "3EECF743-25E8-4483-AA68-B304B38A9290", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "2F557157-AAD6-4601-84C2-2F8574F23683", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "A6BF6644-AF29-4541-9D6A-D07D0CC026F0", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_comfort_panels_22\\\"_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "C4FD5396-8094-4DD0-BE7B-0FB6CC6D45F1", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_comfort_panels_22\\\":-:*:*:*:*:*:*:*", "matchCriteriaId": "DFDC8157-7EA3-4BC4-82C1-06A307996F45", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A8EC6926-258F-4F5C-88D2-33FE363340DB", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "97E283EF-A950-40E7-91C7-839203A333A5", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "B5B130C2-28B8-464C-981C-B5662B4B4309", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "79407355-4181-4082-A661-C27734D95363", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "8989C7D4-5246-443E-B6E4-8E91462B2E96", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "2BFBC5B2-B00B-4FCD-86B1-A187122035AB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "B47671A7-A8DB-4DA2-9076-78708C7F1C42", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*", "matchCriteriaId": "F106DEE3-4DED-46E4-9661-9D9C7B729BC0", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "2D9CF819-E06C-4EAA-85B3-AC40E039D485", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4AF727E5-7849-4980-8AA5-7469FD52DF86", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "F36ABC58-C9FE-4F4A-AB81-26D48A79FFD2", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "A87DD9FF-9CA3-4AE2-8C86-C30A779E0CE6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "891AF48F-1F4D-4AB8-AE66-FBABDD2CAA76", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5052CB07-626A-46C4-8966-B8C9325A3BB3", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "6CD47CC7-1414-42C9-94C6-9DBC2C1D9CBE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*", "matchCriteriaId": "D175BC55-2EAA-4D4A-9E05-2FBB228160F1", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B28FB484-526A-437E-80E3-B62F54F1BEF6", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "61DFC57F-0359-4B4A-A13C-067B21D3DA7B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "81CE70BF-EBBE-4CD7-999C-25662670EFCB", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "034B7CFC-1234-4914-8C84-7E5BD5FB6E4D", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "221EB3AE-1420-46F8-9EAD-1914503B0435", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "5F9A416C-277F-44B0-A74C-263CB0C37D03", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "FA858127-69A0-4280-80A8-65E0778A90AD", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*", "matchCriteriaId": "5C39166C-38CA-426F-9702-B9CA5ED6630C", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "66FC2264-7DDD-4BEF-9795-AC6A5A00886B", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "D68363A9-D1D5-4E49-98D1-E5F8C324BC22", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "A35D0B0C-695D-4274-8B9E-69ED20B62585", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "FE9C9981-BA54-48BB-A89D-3CA06C7E17C6", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "EA400339-123F-494A-8CD8-7232281E7D29", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "C8E943A5-E35C-4CFA-8998-A74385C8740B", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "F4D7038E-C705-4FB9-A2D3-82FFC8EE80CC", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*", "matchCriteriaId": "D29338CD-57BD-4734-9204-118EA53D42FB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "8E4F0084-91A5-4D7E-971B-9DB979849594", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "36EEF9EB-91EF-4697-A963-7C8F955778EC", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "AA0728BD-F463-456C-A6EB-9FF2FD42AA23", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "7BB0B884-C99A-4854-992F-8588840CC296", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "04BA4916-5693-4915-B4D7-29D97FA02474", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "DC588CE7-1F9D-43EF-A478-C23C8D909685", "vulnerable": true }, { "criteria": "cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "2DE08529-E210-48C1-A7C3-D2D316902A40", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*", "matchCriteriaId": "9E7858AB-F89E-4E50-8873-DE8F5F2A07CB", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:*:*:*:*:*:*:*:*", "matchCriteriaId": "06364800-4C54-4BE4-B4AA-0CF29E4E82AA", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "4FBDFA7B-504A-4F58-967F-15CAFCEB5594", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update1:*:*:*:*:*:*", "matchCriteriaId": "4D184A8F-963A-4730-AED4-1994EEA91702", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update2:*:*:*:*:*:*", "matchCriteriaId": "16DAC92E-141C-4923-96F5-2620F60E763A", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update3:*:*:*:*:*:*", "matchCriteriaId": "B3300D8B-E0A1-4CEF-8BE0-AED3F19E9015", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update4:*:*:*:*:*:*", "matchCriteriaId": "8104E528-ED7D-451E-8834-057295A7FF49", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_wincc_runtime_advanced:15.1:update5:*:*:*:*:*:*", "matchCriteriaId": "0AF02DF4-7190-4F6C-8F15-37581FFC9B86", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026amp; 15\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incluyendo las variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (Todas las versiones anteriores a V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (Todas las versiones anteriores a V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (Todas las versiones anteriores a V16 Update 4), SINAMICS GH150 (Todas las versiones), SINAMICS GL150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS GM150 (con opci\u00f3n X30) (Todas las versiones), SINAMICS SH150 (Todas las versiones), SINAMICS SL150 (Todas las versiones), SINAMICS SM120 (Todas las versiones), SINAMICS SM150 (Todas las versiones), SINAMICS SM150i (Todas las versiones). SmartVNC presenta una vulnerabilidad de fuga de asignaci\u00f3n de la pila en el manejador de dise\u00f1o del dispositivo en el lado del cliente, lo que podr\u00eda resultar en una condici\u00f3n de Denegaci\u00f3n de Servicio" } ], "id": "CVE-2021-27386", "lastModified": "2024-11-21T05:57:53.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2021-05-12T14:15:11.767", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "productcert@siemens.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-401" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-401" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
cve-2021-27386
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_CONFIRM | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.446Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-401", "description": "CWE-401: Missing Release of Memory after Effective Lifetime", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:18", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27386", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-401: Missing Release of Memory after Effective Lifetime" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27386", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.446Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-15798
Vulnerability from cvelistv5
Published
2021-02-09 15:38
Modified
2024-08-04 13:30
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02 | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf | x_refsource_CONFIRM |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) |
Version: All versions < V16 Update 3a |
||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:30:21.706Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 3a" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 3a" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-10T10:35:22", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-15798", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 3a" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 3a" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions \u003c V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046)" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-520004.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-033-02" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-752103.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-15798", "datePublished": "2021-02-09T15:38:17", "dateReserved": "2020-07-15T00:00:00", "dateUpdated": "2024-08-04T13:30:21.706Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27385
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.474Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:17", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27385", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27385", "datePublished": "2021-05-12T13:18:23", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.474Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27383
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.589Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-770", "description": "CWE-770: Allocation of Resources Without Limits or Throttling", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:15", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-770: Allocation of Resources Without Limits or Throttling" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27383", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.589Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-27384
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-03 20:48
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf | x_refsource_MISC | |
https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf | x_refsource_MISC | |
https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11 | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) |
Version: All versions < V15.1 Update 6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T20:48:16.461Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 6" } ] }, { "product": "SIMATIC WinCC Runtime Advanced V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SINAMICS GH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GL150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS GM150 (with option X30)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SH150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SL150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM120", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SINAMICS SM150i", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-788", "description": "CWE-788: Access of Memory Location After End of Buffer", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-10-12T09:49:16", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-27384", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants)\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F\n", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 6" } ] } }, { "product_name": "SIMATIC WinCC Runtime Advanced V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SINAMICS GH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GL150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS GM150 (with option X30)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SH150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SL150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM120", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SINAMICS SM150i", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\\\" \u0026 15\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI Comfort Panels V15 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\\\" - 22\\\" (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions \u003c V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions \u003c V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-788: Access of Memory Location After End of Buffer" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf" }, { "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-131-11" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-27384", "datePublished": "2021-05-12T13:18:22", "dateReserved": "2021-02-18T00:00:00", "dateUpdated": "2024-08-03T20:48:16.461Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }