All the vulnerabilites related to siemens - siprotec_compact_model_en100
Vulnerability from fkie_nvd
Published
2016-05-31 01:59
Modified
2024-11-21 02:52
Summary
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6A83974-66CD-409D-A309-568578F44A69",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7rw80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2883847C-7500-4431-8EB9-0B7B4DABC4FD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sd80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72C34F7E-F579-4830-A5E9-F61F71142153",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sj80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF126B3F-B400-43B1-AC08-9458055B7449",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sj81:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E3AAB3-A15B-4159-B7A2-EA70D216B620",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sk80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA7F273D-9E60-45AB-9BBD-434D45FA0608",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sk81:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "411C805A-16C5-4430-8F23-2D5E4D5A423E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_4_en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D3FF8F1-73E6-4F1E-8222-E9191D6A764E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7CE743D-D5A1-4E58-A8C8-1DC755286B54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:4.26:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DB48800-BDF6-4BF9-8383-39693568CF67",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.83; SIPROTEC 7UT686: todas las versiones anteriores a la V 4.01; SIPROTEC 7SD686: todas las versiones anteriores a la V 4.03 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.20. El servidor web integrado (puerto 80/tcp) de los dispositivos afectados podr\u00eda permitir que los atacantes remotos obtengan informaci\u00f3n sensible del dispositivo si obtienen acceso de red."
    }
  ],
  "id": "CVE-2016-4784",
  "lastModified": "2024-11-21T02:52:57.940",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-05-31T01:59:12.993",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/90773"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/99471"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/90773"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/99471"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2016-4784
Vulnerability from cvelistv5
Published
2016-05-31 01:00
Modified
2024-09-17 03:59
Severity ?
Summary
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:39:26.113Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "name": "90773",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/90773"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "name": "90773",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/90773"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-4784",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "90773",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/90773"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-4784",
    "datePublished": "2016-05-31T01:00:00Z",
    "dateReserved": "2016-05-11T00:00:00",
    "dateUpdated": "2024-09-17T03:59:26.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}