All the vulnerabilites related to siemens - siprotec_firmware
Vulnerability from fkie_nvd
Published
2016-05-31 01:59
Modified
2024-11-21 02:52
Summary
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6A83974-66CD-409D-A309-568578F44A69",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7rw80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2883847C-7500-4431-8EB9-0B7B4DABC4FD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sd80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72C34F7E-F579-4830-A5E9-F61F71142153",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sj80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF126B3F-B400-43B1-AC08-9458055B7449",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sj81:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E3AAB3-A15B-4159-B7A2-EA70D216B620",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sk80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA7F273D-9E60-45AB-9BBD-434D45FA0608",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sk81:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "411C805A-16C5-4430-8F23-2D5E4D5A423E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_4_en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D3FF8F1-73E6-4F1E-8222-E9191D6A764E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D7CE743D-D5A1-4E58-A8C8-1DC755286B54",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:4.26:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DB48800-BDF6-4BF9-8383-39693568CF67",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02; SIPROTEC 7SJ686: todas las versiones anteriores a la V 4.83; SIPROTEC 7UT686: todas las versiones anteriores a la V 4.01; SIPROTEC 7SD686: todas las versiones anteriores a la V 4.03 y SIPROTEC 7SJ66: todas las versiones anteriores a la V 4.20. El servidor web integrado (puerto 80/tcp) de los dispositivos afectados podr\u00eda permitir que los atacantes remotos obtengan informaci\u00f3n sensible del dispositivo si obtienen acceso de red."
    }
  ],
  "id": "CVE-2016-4784",
  "lastModified": "2024-11-21T02:52:57.940",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-05-31T01:59:12.993",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/90773"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/99471"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/90773"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/99471"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2015-07-18 10:59
Modified
2024-11-21 02:32
Severity ?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.
Impacted products



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:4.24:*:*:*:*:*:*:*",
              "matchCriteriaId": "54A8F628-D8DD-48A1-BC79-802E7573CDA0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_4:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4F0799D8-BFAC-4DC7-B465-9C757923DD94",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "24E3447F-6F7D-40B0-9D48-68C07FFA133B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. Los paquetes especialmente manipulados enviados al puerto 50000/UDP podr\u00edan provocar una denegaci\u00f3n de servicio (DoS) en el dispositivo afectado. Podr\u00eda ser necesario el reinicio manual para recuperar el servicio del dispositivo."
    }
  ],
  "id": "CVE-2015-5374",
  "lastModified": "2024-11-21T02:32:54.457",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2015-07-18T10:59:04.117",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/75948"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://www.exploit-db.com/exploits/44103/"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/75948"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.exploit-db.com/exploits/44103/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-19"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

Vulnerability from fkie_nvd
Published
2016-05-31 01:59
Modified
2024-11-21 02:52
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_4_en100:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9D3FF8F1-73E6-4F1E-8222-E9191D6A764E",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6D469D9-63E9-4744-8536-23B57DB69FA4",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:4.26:*:*:*:*:*:*:*",
              "matchCriteriaId": "1DB48800-BDF6-4BF9-8383-39693568CF67",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7rw80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2883847C-7500-4431-8EB9-0B7B4DABC4FD",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sd80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "72C34F7E-F579-4830-A5E9-F61F71142153",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sj80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BF126B3F-B400-43B1-AC08-9458055B7449",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sj81:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "73E3AAB3-A15B-4159-B7A2-EA70D216B620",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sk80:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "EA7F273D-9E60-45AB-9BBD-434D45FA0608",
              "vulnerable": false
            },
            {
              "criteria": "cpe:2.3:h:siemens:siprotec_compact_model_7sk81:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "411C805A-16C5-4430-8F23-2D5E4D5A423E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:siprotec_firmware:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D6A83974-66CD-409D-A309-568578F44A69",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en la variante de Firmware PROFINET IO para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.04.01; la variante de Firmware Modbus TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.11.00; la variante de Firmware v TCP para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.03; la variante de Firmware IEC 104 para los m\u00f3dulos EN100 Ethernet: en todas las versiones anteriores a V1.21 y el m\u00f3dulo EN100 Ethernet incluido en SIPROTEC Merging Unit 6MU80: todas las versiones anteriores a la 1.02.02. El servidor web integrado (puerto 80/tcp) de los dispositivos afectados podr\u00eda permitir que los atacantes remotos obtengan una cantidad limitada de contenido de la memoria si obtienen acceso de red. Esta vulnerabilidad solo afecta al m\u00f3dulo EN100 Ethernet incluido en los dispositivos SIPROTEC4 y SIPROTEC Compact."
    }
  ],
  "id": "CVE-2016-4785",
  "lastModified": "2024-11-21T02:52:58.097",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 5.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2016-05-31T01:59:14.227",
  "references": [
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/90773"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securityfocus.com/bid/99471"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/90773"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securityfocus.com/bid/99471"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-200"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2016-4784
Vulnerability from cvelistv5
Published
2016-05-31 01:00
Modified
2024-09-17 03:59
Severity ?
Summary
A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02; SIPROTEC 7SJ686 : All versions < V 4.83; SIPROTEC 7UT686 : All versions < V 4.01; SIPROTEC 7SD686 : All versions < V 4.03; SIPROTEC 7SJ66 : All versions < V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:39:26.113Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "name": "90773",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/90773"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "name": "90773",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/90773"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-4784",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02; SIPROTEC 7SJ686 : All versions \u003c V 4.83; SIPROTEC 7UT686 : All versions \u003c V 4.01; SIPROTEC 7SD686 : All versions \u003c V 4.03; SIPROTEC 7SJ66 : All versions \u003c V 4.20. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain sensitive device information if network access was obtained."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "90773",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/90773"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-4784",
    "datePublished": "2016-05-31T01:00:00Z",
    "dateReserved": "2016-05-11T00:00:00",
    "dateUpdated": "2024-09-17T03:59:26.394Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2015-5374
Vulnerability from cvelistv5
Published
2015-07-18 10:00
Modified
2024-09-17 02:15
Severity ?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:41:09.550Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
          },
          {
            "name": "44103",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/44103/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "name": "75948",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/75948"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T16:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
        },
        {
          "name": "44103",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/44103/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "name": "75948",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/75948"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2015-5374",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. Specially crafted packets sent to port 50000/UDP could cause a denial-of-service of the affected device. A manual reboot may be required to recover the service of the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-732541.pdf"
            },
            {
              "name": "44103",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/44103/"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-202-01"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "75948",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/75948"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2015-5374",
    "datePublished": "2015-07-18T10:00:00Z",
    "dateReserved": "2015-07-06T00:00:00",
    "dateUpdated": "2024-09-17T02:15:53.925Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

cve-2016-4785
Vulnerability from cvelistv5
Published
2016-05-31 01:00
Modified
2024-09-16 19:45
Severity ?
Summary
A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions < V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions < V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions < V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions < V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions < 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T00:39:26.309Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
          },
          {
            "name": "90773",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/90773"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
          },
          {
            "name": "99471",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99471"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2017-07-04T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-03-22T17:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
        },
        {
          "name": "90773",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/90773"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
        },
        {
          "name": "99471",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "DATE_PUBLIC": "2017-07-04T00:00:00",
          "ID": "CVE-2016-4785",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Firmware variant PROFINET IO for EN100 Ethernet module : All versions \u003c V1.04.01; Firmware variant Modbus TCP for EN100 Ethernet module : All versions \u003c V1.11.00; Firmware variant DNP3 TCP for EN100 Ethernet module : All versions \u003c V1.03; Firmware variant IEC 104 for EN100 Ethernet module : All versions \u003c V1.21; EN100 Ethernet module included in SIPROTEC Merging Unit 6MU80 : All versions \u003c 1.02.02. The integrated web server (port 80/tcp) of the affected devices could allow remote attackers to obtain a limited amount of device memory content if network access was obtained. This vulnerability only affects EN100 Ethernet module included in SIPROTEC4 and SIPROTEC Compact devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-547990.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-140-02"
            },
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_SSA-323211.pdf"
            },
            {
              "name": "90773",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/90773"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-03"
            },
            {
              "name": "99471",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2016-4785",
    "datePublished": "2016-05-31T01:00:00Z",
    "dateReserved": "2016-05-11T00:00:00",
    "dateUpdated": "2024-09-16T19:45:44.153Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}