A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA9BAFAE-C26A-4435-80C1-508F0A3EF768", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6D968D9-2A64-4E1C-824F-6508AEC6789D", "versionEndExcluding": "16", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*", "matchCriteriaId": "EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE934FDC-666F-4D9D-9C03-2896875F0A0D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA57190F-97BA-4D1D-BC73-F37162B775F9", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3. 0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15.1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). Un componente dentro de la aplicaci\u00f3n afectada llama a un binario de ayuda con privilegios de SISTEMA durante el inicio mientras la ruta de llamada no est\u00e1 citada. Esto podr\u00eda permitir a un atacante local con privilegios administrativos ejecutar c\u00f3digo con privilegios de nivel SYSTEM" } ], "id": "CVE-2020-7581", "lastModified": "2024-11-21T05:37:24.977", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "integrityImpact": "COMPLETE", "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, "exploitabilityScore": 3.9, "impactScore": 10.0, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.587", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "E927136F-3870-47AD-BE56-C83FBD7BB7E9", "versionEndExcluding": "3.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "matchCriteriaId": "0F8E56A4-77DB-4938-93E5-2CA22222FD6A", "versionEndExcluding": "2.6", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "218D5A8B-FC2D-440C-B853-35E93A025A6E", "versionEndExcluding": "8.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "32A732D2-5E9E-4C8B-93C1-2E0BEBA7B327", "versionEndExcluding": "3.0", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:3.0:-:*:*:*:*:*:*", "matchCriteriaId": "B275D75A-1869-4660-A1FF-837A9C0F874B", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "6729BE2B-6729-4041-BC8C-2AD039467B9A", "versionEndExcluding": "15.1", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "C470C8EF-BBF5-4940-944E-2460BA6D8A27", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update1:*:*:*:*:*:*", "matchCriteriaId": "EF2D6947-576B-4CA7-B4E4-F0B428FA5ABB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "098E9BE1-D698-4DE5-96C1-DF0B3806C935", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "8DA3C5DB-8D27-4CDD-AA93-ABE1EE021CAF", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:16:-:*:*:*:*:*:*", "matchCriteriaId": "8829878A-34E1-44D5-B4BC-12CF67CB58C2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "D1E0C95F-8201-4F04-99A6-62B9684BF35F", "versionEndExcluding": "15.1", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:15.1:-:*:*:*:*:*:*", "matchCriteriaId": "7039A3C6-5DE3-4980-8A2F-A05928561673", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de m\u00faltiples paquetes especialmente dise\u00f1ados al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara. En algunos casos la vulnerabilidad podr\u00eda filtrar informaci\u00f3n aleatoria del servicio remoto" } ], "id": "CVE-2020-7587", "lastModified": "2024-11-21T05:37:25.533", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.4, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 4.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 4.2, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.930", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-400" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
Vulnerability from fkie_nvd
Published
2020-07-14 14:15
Modified
2024-11-21 05:37
Severity ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
References
Impacted products
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:opcenter_execution_discrete:*:*:*:*:*:*:*:*", "matchCriteriaId": "F33BF89C-F36E-4C8F-ABB9-579E2022DDA6", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_foundation:*:*:*:*:*:*:*:*", "matchCriteriaId": "1DCE5E06-B75F-4D21-96CC-70DD373B1811", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_execution_process:*:*:*:*:*:*:*:*", "matchCriteriaId": "C4DD5C57-5877-495C-A01E-747E5DCED9F7", "versionEndExcluding": "3.2", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_intelligence:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA9BAFAE-C26A-4435-80C1-508F0A3EF768", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_quality:*:*:*:*:*:*:*:*", "matchCriteriaId": "9DB2F53B-817C-41F3-9B52-85DE702ACCE5", "versionEndExcluding": "11.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:opcenter_rd\\\u0026l:8.0:*:*:*:*:*:*:*", "matchCriteriaId": "EE037602-C9E8-45D5-9A44-3B73052F478E", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_lms:*:*:*:*:*:*:*:*", "matchCriteriaId": "524AE90C-821A-4864-B3B2-33C083B536CB", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_it_production_suite:*:*:*:*:*:*:*:*", "matchCriteriaId": "E6324685-60ED-44CC-BAEA-3BEEBE681AC5", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_notifier_server:*:*:*:*:*:windows:*:*", "matchCriteriaId": "DE74021F-CE57-42CC-8093-E1B0352410FA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "matchCriteriaId": "D61D4B81-7F51-49BE-83DD-D2C28D23B0EA", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:*:*:*:*:*:*:*:*", "matchCriteriaId": "2190AEE1-7EEA-48A9-B6C7-FF4B3A26008E", "versionEndIncluding": "15.1", "versionStartIncluding": "15", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:-:*:*:*:*:*:*", "matchCriteriaId": "66CB66B9-176E-4FA3-BC67-E7C5972A307C", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simatic_step_7:16:update_1:*:*:*:*:*:*", "matchCriteriaId": "4E011D6F-CC5F-4278-80AB-D568730AA041", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:simocode_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "CE934FDC-666F-4D9D-9C03-2896875F0A0D", "vulnerable": true }, { "criteria": "cpe:2.3:a:siemens:soft_starter_es:*:*:*:*:*:*:*:*", "matchCriteriaId": "FA57190F-97BA-4D1D-BC73-F37162B775F9", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Opcenter Execution Discrete (Todas las versiones anteriores a V3.2), Opcenter Execution Foundation (Todas las versiones anteriores a V3.2), Opcenter Execution Process (Todas las versiones anteriores a V3.2), Opcenter Intelligence (Todas las versiones anteriores a V3.3), Opcenter Quality (Todas las versiones anteriores a V11.3), Opcenter RD\u0026amp;L (V8.0), SIMATIC IT LMS (Todas las versiones anteriores a V2.6), SIMATIC IT Production Suite (Todas las versiones anteriores a V8. 0), SIMATIC Notifier Server for Windows (Todas las versiones), SIMATIC PCS neo (Todas las versiones anteriores a V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a V16 Update 2), SIMOCODE ES V15. 1 (Todas las versiones anteriores a V15.1 Update 4), SIMOCODE ES V16 (Todas las versiones anteriores a V16 Update 1), Soft Starter ES V15.1 (Todas las versiones anteriores a V15.1 Update 3), Soft Starter ES V16 (Todas las versiones anteriores a V16 Update 1). El env\u00edo de un paquete especialmente dise\u00f1ado al servicio afectado podr\u00eda causar una denegaci\u00f3n de servicio remota parcial, que har\u00eda que el servicio se reiniciara" } ], "id": "CVE-2020-7588", "lastModified": "2024-11-21T05:37:25.660", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "MEDIUM", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2020-07-14T14:15:18.993", "references": [ { "source": "productcert@siemens.com", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "productcert@siemens.com", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-20" } ], "source": "nvd@nist.gov", "type": "Secondary" } ] }
cve-2020-7588
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.850Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC IT LMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6" } ] }, { "product": "SIMATIC IT Production Suite", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:56", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7588", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC IT LMS", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6" } ] } }, { "product_name": "SIMATIC IT Production Suite", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending a specially crafted packet to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7588", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.850Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7581
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.617Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-428", "description": "CWE-428: Unquoted Search Path or Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:47", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7581", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-428: Unquoted Search Path or Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7581", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.617Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2020-7587
Vulnerability from cvelistv5
Published
2020-07-14 13:18
Modified
2024-08-04 09:33
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC IT LMS (All versions < V2.6), SIMATIC IT Production Suite (All versions < V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service.
References
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf | x_refsource_MISC |
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Opcenter Execution Discrete |
Version: All versions < V3.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T09:33:19.877Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Opcenter Execution Discrete", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Foundation", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Execution Process", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2" } ] }, { "product": "Opcenter Intelligence", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3" } ] }, { "product": "Opcenter Quality", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V11.3" } ] }, { "product": "Opcenter RD\u0026L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V8.0" } ] }, { "product": "SIMATIC IT LMS", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.6" } ] }, { "product": "SIMATIC IT Production Suite", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V8.0" } ] }, { "product": "SIMATIC Notifier Server for Windows", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC PCS neo", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.0 SP1" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V15", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 5" } ] }, { "product": "SIMATIC STEP 7 (TIA Portal) V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 2" } ] }, { "product": "SIMOCODE ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 4" } ] }, { "product": "SIMOCODE ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] }, { "product": "Soft Starter ES V15.1", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V15.1 Update 3" } ] }, { "product": "Soft Starter ES V16", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-10T11:16:51", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2020-7587", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Opcenter Execution Discrete", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Foundation", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Execution Process", "version": { "version_data": [ { "version_value": "All versions \u003c V3.2" } ] } }, { "product_name": "Opcenter Intelligence", "version": { "version_data": [ { "version_value": "All versions \u003c V3.3" } ] } }, { "product_name": "Opcenter Quality", "version": { "version_data": [ { "version_value": "All versions \u003c V11.3" } ] } }, { "product_name": "Opcenter RD\u0026L", "version": { "version_data": [ { "version_value": "V8.0" } ] } }, { "product_name": "SIMATIC IT LMS", "version": { "version_data": [ { "version_value": "All versions \u003c V2.6" } ] } }, { "product_name": "SIMATIC IT Production Suite", "version": { "version_data": [ { "version_value": "All versions \u003c V8.0" } ] } }, { "product_name": "SIMATIC Notifier Server for Windows", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC PCS neo", "version": { "version_data": [ { "version_value": "All versions \u003c V3.0 SP1" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V15", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 5" } ] } }, { "product_name": "SIMATIC STEP 7 (TIA Portal) V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 2" } ] } }, { "product_name": "SIMOCODE ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 4" } ] } }, { "product_name": "SIMOCODE ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } }, { "product_name": "Soft Starter ES V15.1", "version": { "version_data": [ { "version_value": "All versions \u003c V15.1 Update 3" } ] } }, { "product_name": "Soft Starter ES V16", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 1" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Opcenter Execution Discrete (All versions \u003c V3.2), Opcenter Execution Foundation (All versions \u003c V3.2), Opcenter Execution Process (All versions \u003c V3.2), Opcenter Intelligence (All versions \u003c V3.3), Opcenter Quality (All versions \u003c V11.3), Opcenter RD\u0026L (V8.0), SIMATIC IT LMS (All versions \u003c V2.6), SIMATIC IT Production Suite (All versions \u003c V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMOCODE ES V15.1 (All versions \u003c V15.1 Update 4), SIMOCODE ES V16 (All versions \u003c V16 Update 1), Soft Starter ES V15.1 (All versions \u003c V15.1 Update 3), Soft Starter ES V16 (All versions \u003c V16 Update 1). Sending multiple specially crafted packets to the affected service could cause a partial remote denial-of-service, that would cause the service to restart itself. On some cases the vulnerability could leak random information from the remote service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2020-7587", "datePublished": "2020-07-14T13:18:05", "dateReserved": "2020-01-21T00:00:00", "dateUpdated": "2024-08-04T09:33:19.877Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }