FKIE_CVE-2024-0912
Vulnerability from fkie_nvd - Published: 2024-06-06 00:15 - Updated: 2024-11-21 08:47
Severity ?
Summary
Under certain circumstances the Microsoft® Internet Information Server (IIS) used to host the C•CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C•CURE 9000 or prior versions
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| johnsoncontrols | software_house_c-cure_9000_siteserver | 3.00.2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:johnsoncontrols:software_house_c-cure_9000_siteserver:3.00.2:*:*:*:*:*:*:*",
"matchCriteriaId": "62D6108E-959F-4F1B-8E6C-6BE05071C1EE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Under certain circumstances the Microsoft\u00ae Internet Information Server (IIS) used to host the C\u2022CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C\u2022CURE 9000 or prior versions"
},
{
"lang": "es",
"value": "En determinadas circunstancias, Microsoft\u00ae Internet Information Server (IIS) utilizado para alojar el servidor web C\u2022CURE 9000 registrar\u00e1 los detalles de las credenciales de Microsoft Windows en los registros. No hay ning\u00fan impacto en las interfaces de servicios que no son web C\u2022CURE 9000 o versiones anteriores"
}
],
"id": "CVE-2024-0912",
"lastModified": "2024-11-21T08:47:42.203",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.6,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "productsecurity@jci.com",
"type": "Secondary"
}
]
},
"published": "2024-06-06T00:15:09.117",
"references": [
{
"source": "productsecurity@jci.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-03"
},
{
"source": "productsecurity@jci.com",
"tags": [
"Product"
],
"url": "https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-04.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-03"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-04.pdf"
}
],
"sourceIdentifier": "productsecurity@jci.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "productsecurity@jci.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-532"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2024-0912 (GCVE-0-2024-0912)
Vulnerability from cvelistv5 – Published: 2024-06-05 23:23 – Updated: 2024-08-01 18:18
VLAI?
Summary
Under certain circumstances the Microsoft® Internet Information Server (IIS) used to host the C•CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C•CURE 9000 or prior versions
Severity ?
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Johnson Controls | Software House C•CURE 9000 |
Affected:
0 , ≤ 2.90
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:johnsoncontrols:c-cure_9000_firmware:3.00.2:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "c-cure_9000_firmware",
"vendor": "johnsoncontrols",
"versions": [
{
"status": "affected",
"version": "3.00.2"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0912",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T13:26:19.917096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T13:29:07.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:18:18.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-04.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Software House C\u2022CURE 9000",
"vendor": "Johnson Controls",
"versions": [
{
"lessThanOrEqual": "2.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-05-14T23:05:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnder certain circumstances the Microsoft\u00ae Internet Information Server (IIS) used to host the C\u2022CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C\u2022CURE 9000 or prior versions\u003c/span\u003e\n\n"
}
],
"value": "Under certain circumstances the Microsoft\u00ae Internet Information Server (IIS) used to host the C\u2022CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C\u2022CURE 9000 or prior versions"
}
],
"impacts": [
{
"capecId": "CAPEC-560",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-560 Use of Known Domain Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T23:24:21.753Z",
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci"
},
"references": [
{
"url": "https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-04.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eUpdate C\u2022CURE 9000 to version 3.00.2 CU02 or 3.00.3\u003cbr\u003e\u003c/p\u003e\u003cp\u003eChange the password for the impacted windows accounts.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eDelete the api.log log file (or remove instances of passwords from the log file with a text editor) located at \"C:\\Program Files (x86)\\Tyco\\victorWebServices\\victorWebsite\\Logs\\archives\"\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Update C\u2022CURE 9000 to version 3.00.2 CU02 or 3.00.3\n\n\nChange the password for the impacted windows accounts.\n\n\nDelete the api.log log file (or remove instances of passwords from the log file with a text editor) located at \"C:\\Program Files (x86)\\Tyco\\victorWebServices\\victorWebsite\\Logs\\archives\""
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CCURE passwords exposed to administrators",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"assignerShortName": "jci",
"cveId": "CVE-2024-0912",
"datePublished": "2024-06-05T23:23:24.863Z",
"dateReserved": "2024-01-25T21:48:54.313Z",
"dateUpdated": "2024-08-01T18:18:18.986Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-0912 (GCVE-0-2024-0912)
Vulnerability from nvd – Published: 2024-06-05 23:23 – Updated: 2024-08-01 18:18
VLAI?
Summary
Under certain circumstances the Microsoft® Internet Information Server (IIS) used to host the C•CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C•CURE 9000 or prior versions
Severity ?
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Johnson Controls | Software House C•CURE 9000 |
Affected:
0 , ≤ 2.90
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:johnsoncontrols:c-cure_9000_firmware:3.00.2:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "c-cure_9000_firmware",
"vendor": "johnsoncontrols",
"versions": [
{
"status": "affected",
"version": "3.00.2"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0912",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-06T13:26:19.917096Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T13:29:07.270Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:18:18.986Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-04.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Software House C\u2022CURE 9000",
"vendor": "Johnson Controls",
"versions": [
{
"lessThanOrEqual": "2.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-05-14T23:05:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnder certain circumstances the Microsoft\u00ae Internet Information Server (IIS) used to host the C\u2022CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C\u2022CURE 9000 or prior versions\u003c/span\u003e\n\n"
}
],
"value": "Under certain circumstances the Microsoft\u00ae Internet Information Server (IIS) used to host the C\u2022CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C\u2022CURE 9000 or prior versions"
}
],
"impacts": [
{
"capecId": "CAPEC-560",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-560 Use of Known Domain Credentials"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "LOW",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:A/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T23:24:21.753Z",
"orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"shortName": "jci"
},
"references": [
{
"url": "https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-04.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-135-03"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cp\u003eUpdate C\u2022CURE 9000 to version 3.00.2 CU02 or 3.00.3\u003cbr\u003e\u003c/p\u003e\u003cp\u003eChange the password for the impacted windows accounts.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eDelete the api.log log file (or remove instances of passwords from the log file with a text editor) located at \"C:\\Program Files (x86)\\Tyco\\victorWebServices\\victorWebsite\\Logs\\archives\"\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "Update C\u2022CURE 9000 to version 3.00.2 CU02 or 3.00.3\n\n\nChange the password for the impacted windows accounts.\n\n\nDelete the api.log log file (or remove instances of passwords from the log file with a text editor) located at \"C:\\Program Files (x86)\\Tyco\\victorWebServices\\victorWebsite\\Logs\\archives\""
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "CCURE passwords exposed to administrators",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
"assignerShortName": "jci",
"cveId": "CVE-2024-0912",
"datePublished": "2024-06-05T23:23:24.863Z",
"dateReserved": "2024-01-25T21:48:54.313Z",
"dateUpdated": "2024-08-01T18:18:18.986Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}