All the vulnerabilites related to sonicwall - sra_va_firmware
Vulnerability from fkie_nvd
Published
2021-08-04 19:15
Modified
2024-11-21 05:45
Severity ?
Summary
Improper neutralization of a SQL Command leading to SQL Injection vulnerability impacting end-of-life Secure Remote Access (SRA) products, specifically the SRA appliances running all 8.x firmware and 9.0.0.9-26sv or earlier



{
  "cisaActionDue": "2022-04-18",
  "cisaExploitAdd": "2022-03-28",
  "cisaRequiredAction": "The impacted product is end-of-life and should be disconnected if still in use.",
  "cisaVulnerabilityName": "SonicWall Secure Remote Access (SRA) SQL Injection Vulnerability",
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sma_210_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA095C77-9E99-4086-A665-D15B62ED6318",
              "versionEndExcluding": "9.0.0.10-28sv",
              "versionStartIncluding": "8.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sma_210:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "51587338-4A5F-41FC-9497-743F061947C2",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sma_410_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "D82266A9-0420-4C82-B7CE-6E35A197C774",
              "versionEndExcluding": "9.0.0.10-28sv",
              "versionStartIncluding": "8.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sma_410:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9DFB8FBC-FFA4-4526-B306-D5692A43DC9E",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sma_500v_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9A5ACCFB-D882-4F7D-8CE4-3608B1053708",
              "versionEndExcluding": "9.0.0.10-28sv",
              "versionStartIncluding": "8.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sma_500v:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6AD8A33-7CE4-4C66-9E23-F0C9C9638770",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sra_4600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4A1739FF-3445-4155-BCD5-FFC3ADC7BB11",
              "versionEndExcluding": "9.0.0.10-28sv",
              "versionStartIncluding": "8.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sra_4600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "2FC9EDA7-6306-4AC0-BBA2-BFC4D6EF7D05",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sra_1600_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56142ABA-8DB5-40C4-B485-CA440BC26EB5",
              "versionEndExcluding": "9.0.0.10-28sv",
              "versionStartIncluding": "8.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sra_1600:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "A19AAF5D-B03D-40BB-AF3C-8BAEFD60C0F7",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:sonicwall:sra_va_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "403EDB9C-7FAE-496D-8307-B76FBC02FE50",
              "versionEndExcluding": "9.0.0.10-28sv",
              "versionStartIncluding": "8.0.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:sonicwall:sra_va:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "43D2892B-20AF-4832-8C14-C2570804A4D0",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [
    {
      "sourceIdentifier": "PSIRT@sonicwall.com",
      "tags": [
        "unsupported-when-assigned"
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Improper neutralization of a SQL Command leading to SQL Injection vulnerability impacting end-of-life Secure Remote Access (SRA) products, specifically the SRA appliances running all 8.x firmware and 9.0.0.9-26sv or earlier"
    },
    {
      "lang": "es",
      "value": "** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** Una neutralizaci\u00f3n inapropiada de un Comando SQL conllevando una vulnerabilidad de Inyecci\u00f3n SQL impactando a los productos Secure Remote Access (SRA) al final de su vida \u00fatil, concretamente a dispositivos SRA que ejecutan todo el firmware 8.x y 9.0.0.9-26sv o anteriores"
    }
  ],
  "id": "CVE-2021-20028",
  "lastModified": "2024-11-21T05:45:48.813",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 7.5,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-04T19:15:08.247",
  "references": [
    {
      "source": "PSIRT@sonicwall.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0017"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0017"
    }
  ],
  "sourceIdentifier": "PSIRT@sonicwall.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "PSIRT@sonicwall.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-89"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2021-20028
Vulnerability from cvelistv5
Published
2021-08-04 19:10
Modified
2024-08-03 17:30
Severity ?
Summary
Improper neutralization of a SQL Command leading to SQL Injection vulnerability impacting end-of-life Secure Remote Access (SRA) products, specifically the SRA appliances running all 8.x firmware and 9.0.0.9-26sv or earlier
References
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:30:07.639Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0017"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SonicWall SRA/SMA100",
          "vendor": "SonicWall",
          "versions": [
            {
              "status": "affected",
              "version": "8.x firmware"
            },
            {
              "status": "affected",
              "version": "9.0.0.9-26sv and earlier."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper neutralization of a SQL Command leading to SQL Injection vulnerability impacting end-of-life Secure Remote Access (SRA) products, specifically the SRA appliances running all 8.x firmware and 9.0.0.9-26sv or earlier"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-08-04T19:10:09",
        "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "shortName": "sonicwall"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0017"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "PSIRT@sonicwall.com",
          "ID": "CVE-2021-20028",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SonicWall SRA/SMA100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "8.x firmware"
                          },
                          {
                            "version_value": "9.0.0.9-26sv and earlier."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "SonicWall"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** Improper neutralization of a SQL Command leading to SQL Injection vulnerability impacting end-of-life Secure Remote Access (SRA) products, specifically the SRA appliances running all 8.x firmware and 9.0.0.9-26sv or earlier."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0017",
              "refsource": "CONFIRM",
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0017"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
    "assignerShortName": "sonicwall",
    "cveId": "CVE-2021-20028",
    "datePublished": "2021-08-04T19:10:09",
    "dateReserved": "2020-12-17T00:00:00",
    "dateUpdated": "2024-08-03T17:30:07.639Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}