All the vulnerabilites related to netgear - srk60b06
Vulnerability from fkie_nvd
Published
2020-06-18 17:15
Modified
2024-11-21 05:03
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104.



{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "56813F5F-CF4B-4A6C-B187-D935A2768D91",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DCC347EB-699E-4626-A944-2D378101DDCF",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E16D818A-5988-4B9D-9083-3070BCF35939",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "BFB01247-A20F-41CA-8718-E8E60E7F14B3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2421F159-B182-4E57-90CA-6D4D19FDD7D9",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "55E6F589-04DA-431C-9E03-BA2A59BB0E4A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srk60b03_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "2CA07F1F-EB90-49A7-97A1-D13DC0083A89",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srk60b03:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6CBE3FD9-04A3-40B7-A839-DAA534B7FD6D",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srk60b04_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F7E07D1-C2EE-4BDD-B195-6CE22D35D3D0",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srk60b04:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B3DD8F7-E860-4B21-B03B-0C4136C3D845",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srk60b05_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "9F9CE8BB-DEFA-40DA-B3D9-893BC5A7D23C",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srk60b05:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F86F7524-4456-48A0-9591-4A17555B990A",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:netgear:srk60b06_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "042F981E-0484-45BF-A935-F6B0382C2522",
              "versionEndExcluding": "2.5.2.104",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:netgear:srk60b06:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B906DFC5-058F-4C31-B92F-49393B15497B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104."
    },
    {
      "lang": "es",
      "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a SRK60 antes de 2.5.2.104, SRS60 antes de 2.5.2.104, SRR60 antes de 2.5.2.104, SRK60B03 antes de 2.5.2.104, SRK60B04 antes de 2.5.2.104, SRK60B05 antes de 2.5.2.104 y SRK60B06 antes de 2.5.2.104"
    }
  ],
  "id": "CVE-2020-14435",
  "lastModified": "2024-11-21T05:03:16.037",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "ADJACENT_NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.5,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.8,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
          "version": "3.0"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.2,
        "source": "cve@mitre.org",
        "type": "Secondary"
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-06-18T17:15:12.640",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000061930/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0026"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://kb.netgear.com/000061930/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0026"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

cve-2020-14435
Vulnerability from cvelistv5
Published
2020-06-18 16:35
Modified
2024-08-04 12:46
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:46:34.516Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000061930/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0026"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:H/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-18T16:35:24",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000061930/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0026"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-14435",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT",
            "availabilityImpact": "NONE",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:H/AV:A/A:N/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000061930/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0026",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000061930/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0026"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-14435",
    "datePublished": "2020-06-18T16:35:24",
    "dateReserved": "2020-06-18T00:00:00",
    "dateUpdated": "2024-08-04T12:46:34.516Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

var-202006-0932
Vulnerability from variot

Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.

Injection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0932",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "srk60",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srs60",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srr60",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b03",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b04",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b05",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b06",
        "scope": "lt",
        "trust": 1.6,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b03",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b04",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b05",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srk60b06",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srr60",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      },
      {
        "model": "srs60",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "netgear",
        "version": "2.5.2.104"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srk60_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srk60:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srs60_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srs60:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srr60_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srr60:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srk60b03_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srk60b03:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srk60b04_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srk60b04:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srk60b05_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srk60b05:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:netgear:srk60b06_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "2.5.2.104",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:netgear:srk60b06:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      }
    ]
  },
  "cve": "CVE-2020-14435",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-006740",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2021-44780",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "author": "cve@mitre.org",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.6,
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-006740",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-14435",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2020-14435",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-006740",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-44780",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202006-1251",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-14435",
        "trust": 3.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ]
  },
  "id": "VAR-202006-0932",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      }
    ],
    "trust": 1.166017337142857
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:28:06.650000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Security Advisory for Pre-Authentication Command Injection on Some WiFi Systems, PSV-2020-0026",
        "trust": 0.8,
        "url": "https://kb.netgear.com/000061930/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0026"
      },
      {
        "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44780)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/275086"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-74",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.0,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14435"
      },
      {
        "trust": 1.6,
        "url": "https://kb.netgear.com/000061930/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0026"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14435"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "date": "2020-07-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "date": "2020-06-18T17:15:12.640000",
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "date": "2020-06-18T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-06-24T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-44780"
      },
      {
        "date": "2020-07-16T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      },
      {
        "date": "2021-07-21T11:39:23.747000",
        "db": "NVD",
        "id": "CVE-2020-14435"
      },
      {
        "date": "2020-07-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  NETGEAR Injection vulnerabilities in devices",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006740"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-1251"
      }
    ],
    "trust": 0.6
  }
}